首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Jung JY  Jee WH  Park MY  Lee SY  Kim YS 《Skeletal radiology》2012,41(11):1401-1410

Objective

To assess the diagnostic performance of shoulder MR arthrography with 3D isotropic fat-suppressed (FS) turbo spin-echo sequence (TSE-SPACE) for supraspinatus tendon tears in comparison with 2D conventional sequences at 3.0?T.

Materials and methods

The study was HIPAA-compliant and approved by the institutional review board with a waiver of informed consent. Eighty-seven arthroscopically confirmed patients who underwent 3.0?T shoulder MR arthrography with 2D sequences and 3D TSE-SPACE were included in a consecutive fashion from March 2009 to February 2010. Two reviewers independently analyzed 2D sequences and 3D TSE-SPACE. Sensitivity, specificity, accuracy, and interobserver agreement (κ) were compared between 2D sequences and 3D TSE-SPACE for full-thickness and partial-thickness supraspinatus tendon tears together and for partial-thickness supraspinatus tendon tears alone.

Results

There were 33 full-thickness tears and 28 partial-thickness tears of supraspinatus tendons. For full-thickness and partial-thickness supraspinatus tendon tears together, the mean sensitivity, specificity, and accuracy of both readers were 96, 92, and 94% on 2D sequences and 91, 84, and 89% on 3D TSE-SPACE. For partial-thickness supraspinatus tendon tears alone, the mean sensitivity, specificity, and accuracy were 95, 92, and 94% on 2D sequences and 84, 85, and 84% on 3D TSE-SPACE. There was no statistical difference between 2D sequences and 3D TSE-SPACE. Interobserver agreements were almost perfect on 2D conventional sequences and substantial on 3D TSE-SPACE.

Conclusion

Compared with 2D conventional sequences, MR arthrography using 3D TSE-SPACE was comparable for diagnosing supraspinatus tendon tears despite limitations in detecting small partial-thickness tears and in discriminating between full-thickness and deep partial-thickness tears.  相似文献   

2.

Purpose

We report the prevalence of supraspinatus tendon tears seen on MR arthrography that are not seen on conventional MR exam in the same patient population.

Materials and methods

A total of 150 consecutive conventional shoulder MR and MR arthrography exams performed on the same patients who went on to arthroscopy were reviewed retrospectively by consensus reading of two musculoskeletal radiologists. Full-thickness supraspinatus tendon tears were assessed. None of the patients had previous shoulder surgery.

Results

There were 113 full-thickness supraspinatus tendon tears seen on conventional MR exam while there were 119 full-thickness supraspinatus tendon tears seen on MR arthrography. The six additional full-thickness supraspinatus tendon tears seen on MR arthrography but not seen on conventional MR exam were confirmed at arthroscopy.

Conclusions

Some full-thickness supraspinatus tendon tears are not seen on conventional MR exam but are seen on MR arthrography. This is most likely due to fibrosis at the supraspinatus tendon tear site simulating an intact tendon on conventional MR.  相似文献   

3.
OBJECTIVE: We sought to compare the diagnostic accuracy of conventional MRI versus MR arthrography of the shoulder in the assessment of high-performance athletes (professional baseball players) and to compare our findings in these patients with the conventional MRI and MR arthrographic findings in an age-matched control group of nonprofessional athletes. MATERIALS AND METHODS: Conventional MRI and MR arthrographic examinations of the shoulder in 20 consecutive professional baseball players with shoulder pain were reviewed retrospectively by two musculoskeletal radiologists in consensus. These interpretations were compared with retrospective consensus interpretations of conventional MRI and MR arthrographic examinations of the shoulder obtained in a control group of 50 consecutive nonprofessional athletes with shoulder pain. MR images were assessed for full- or partial-thickness supraspinatus tendon tears, superior labral anteroposterior (SLAP) tears, and anterior or posterior labral tears. RESULTS: In the 20 consecutive professional athlete patients, two full-thickness and six partial-thickness undersurface supraspinatus tendon tears were seen on MR arthrography but not seen on conventional MRI as well as six SLAP tears, two anterior labral tears, and one posterior labral tear. Three patients had both SLAP tears and full- or partial-thickness supraspinatus tendon tears. Of 14 patients with findings on MR arthrography that were not seen on MRI, 11 had arthroscopic correlation. In all 11, arthroscopic findings confirmed findings on MR arthrography. In the group of 50 nonprofessional athlete patients, five had additional findings on MR arthrography not seen on conventional MRI: two anterior labral tears, two partial-thickness supraspinatus tendon tears, and two SLAP tears. One patient had both a partial-thickness supraspinatus tendon tear and a SLAP tear seen on MR arthrography. The five patients with additional findings on MR arthrography had arthroscopy. In all five, arthroscopic findings confirmed the findings on MR arthrography. CONCLUSION: MR arthrography is considerably more sensitive for detection of partial-thickness supraspinatus tears and labral tears than conventional MRI. MR arthrography showed injuries in addition to those seen on conventional MRI in 14 of 20 patients in the high-performance athlete group. These results suggest high-performance athletes may be a subgroup of patients for whom MR arthrography yields considerably more diagnostic information than conventional MRI.  相似文献   

4.
PURPOSE: To determine which US signs are important in the diagnosis of a surgically identifiable supraspinatus tendon tear. MATERIALS AND METHODS: Fifty consecutive ultrasonographic (US) studies of the shoulder in patients who underwent arthroscopic follow-up were retrospectively reviewed by a musculoskeletal radiologist. US images of the supraspinatus tendon were evaluated for tendon nonvisualization, abnormal tendon echogenicity, tendon thinning, greater tuberosity cortical irregularity, cartilage interface sign, joint fluid, and subacromial-subdeltoid bursal fluid. US findings were compared with arthroscopic results. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were calculated for each US sign in the diagnosis of full-thickness tendon tear and again for any type of supraspinatus tendon tear. RESULTS: Arthroscopy revealed 21 full-thickness tears, five bursal surface partial-thickness tears, 10 articular surface partial-thickness tears, and 14 patients without tear of the supraspinatus tendon. The presence of greater tuberosity cortical irregularity and joint fluid was most important in the diagnosis of full-thickness supraspinatus tendon tear (sensitivity, 60%; specificity, 100%; positive predictive value, 100%; negative predictive value, 78%; accuracy, 84%). For diagnosis of any type of supraspinatus tendon tear (partial or full thickness), tendon nonvisualization, greater tuberosity cortical irregularity, and cartilage interface sign are most important, although a combination of signs did not improve accuracy. CONCLUSION: Secondary US signs, such as greater tuberosity cortical irregularity and joint fluid, are most valuable in the diagnosis of supraspinatus tendon tear.  相似文献   

5.

Purpose

To compare the accuracy of ultrasonography and MR arthrography (MRA) imaging in detecting of rotator cuff tears with arthroscopic finding used as the reference standard.

Methods

The ultrasonography and MRA findings of 51 shoulders that underwent the arthroscopic surgery were prospectively analysed. Two orthopaedic doctors independently performed ultrasonography and interpreted the findings at the office. The tear size measured at ultrasonography and MRA was compared with the size measured at surgery using Pearson correlation coefficients (r). The sensitivity, specificity, accuracy, positive predictive value, negative predictive value and false-positive rate were calculated for a diagnosis of partial-and full-thickness rotator cuff tears. The kappa coefficient was calculated to verify the inter-observer agreement.

Results

The sensitivity of ultrasonography and MRA for detecting partial-thickness tears was 45.5 and 72.7 %, and that for full-thickness tears was 80.0 and 100 %, respectively. The accuracy of ultrasonograpy and MRA for detecting partial-thickness tears was 45.1 and 88.2 %, and that for full-thickness tears was 82.4 and 98 %, respectively. Tear size measured based on ultrasonography examination showed a poor correlation with the size measured at arthroscopic surgery (r = 0.21; p < 0.05). However, tear size estimated by MRA showed a strong correlation (r = 0.75; p < 0.05). The kappa coefficient was 0.47 between the two independent examiners.

Conclusions

The accuracy of office-based ultrasonography for beginner orthopaedic surgeons to detect full-thickness rotator cuff tears was comparable to that of MRA but was less accurate for detecting partial-thickness tears and torn size measurement. Inter-observer agreement on the interpretation was fair. These results highlight the importance of the correct technique and experience in operation of ultrasonography in shoulder joint.

Level of evidence

Diagnostic study, Level II.  相似文献   

6.
We assessed the diagnostic performance of magnetic resonance (MR) arthrography in the diagnosis of articular-sided partial-thickness and full-thickness rotator cuff tears in a large symptomatic population. MR arthrograms obtained in 275 patients including a study group of 139 patients with rotator cuff tears proved by arthroscopy and a control group of 136 patients with arthroscopically intact rotator cuff tendons were reviewed in random order. MR imaging was performed on a 1.0 T system (Magnetom Expert, Siemens). MR arthrograms were analyzed by two radiologists in consensus for articular-sided partial-thickness and full-thickness tears of the supraspinatus, infraspinatus, and subscapularis tendons. At arthroscopy, 197 rotator cuff tears were diagnosed, including 105 partial-thickness (93 supraspinatus, nine infraspinatus, three subscapularis) and 92 full-thickness (43 supraspinatus, 20 infraspinatus, 29 subscapularis) tendon tears. For full-thickness tears, sensitivity, specificity, and accuracy were 96%, 99%, and 98%, respectively, and for partial tears 80%, 97%, and 95%, respectively. False negative and positive assessments in the diagnosis of articular-sided partial-thickness tears were predominantly [78% (35/45)] observed with small articular-sided (Ellman grade1) tendon tears. MR arthrography is highly accurate in the diagnosis of full-thickness rotator cuff tears and is accurate in the diagnosis of articular-sided partial-thickness tears. Limitations in the diagnosis of partial-thickness tears are mainly restricted to small articular-sided tears (Ellman grade 1) due to difficulties in differentiation between fiber tearing, tendinitis, synovitic changes, and superficial fraying at tendon margins.  相似文献   

7.

Objective

To compare the accuracy between a three-dimensional (3D) indirect isotropic T1-weighted fast spin-echo (FSE) magnetic resonance (MR) arthrography and a conventional two-dimensional (2D) T1-weighted sequences of indirect MR arthrography for diagnosing rotator cuff tears.

Materials and Methods

The study was approved by our Institutional Review Board. In total, 205 patients who had undergone indirect shoulder MR arthrography followed by arthroscopic surgery for 206 shoulders were included in this study. Both conventional 2D T1-weighted FSE sequences and 3D isotropic T1-weighted FSE sequence were performed in all patients. Two radiologists evaluated the images for the presence of full- or partial-thickness tears in the supraspinatus-infraspinatus (SSP-ISP) tendons and tears in the subscapularis (SSC) tendons. Using the arthroscopic findings as the reference standard, the diagnostic performances of both methods were analyzed by the area under the receiver operating characteristic curve (AUC).

Results

Arthroscopy confirmed 165 SSP-ISP tendon tears and 103 SSC tendon tears. For diagnosing SSP-ISP tendon tears, the AUC values were 0.964 and 0.989 for the 2D sequences and 3D T1-weighted FSE sequence, respectively, in reader I and 0.947 and 0.963, respectively, in reader II. The AUC values for diagnosing SSC tendon tears were 0.921 and 0.925, respectively, for reader I and 0.856 and 0.860, respectively, for reader II. There was no significant difference between the AUC values of the 2D and 3D sequences in either reader for either type of tear.

Conclusion

3D indirect isotropic MR arthrography with FSE sequence and the conventional 2D arthrography are not significantly different in terms of accuracy for diagnosing rotator cuff tears.  相似文献   

8.

Purpose

To compare the accuracy of ultrasonography and magnetic resonance imaging in the detection of rotator cuff tears.

Materials and methods

Ninety-six patients with clinically suspected rotator cuff pathology underwent ultrasonography and magnetic resonance imaging of the shoulder. The findings in 88 patients were compared with arthroscopy or open surgery.

Results

Full-thickness tear was confirmed in 57 cases, partial-thickness tear in 30 cases and degenerative changes without tear in 1. In all 57 cases of full-thickness tear and in 28 out of 30 cases of partial-thickness tear the supraspinatus tendon was involved. The accuracy in the detection of full-thickness tears was 98 and 100% for ultrasonography and magnetic resonance imaging, respectively. The accuracy in the detection of bursal or articular partial-thickness tears was 87 and 90% for ultrasonography and magnetic resonance imaging, respectively.

Conclusions

In experienced hands ultrasonography should be considered as an accurate modality for the initial investigation of rotator cuff, especially supraspinatus, tears.  相似文献   

9.

Objective

To evaluate the need for additional magnetic resonance imaging (MRI) following ultrasound (US) in patients with shoulder pain and/or disability and to compare the accuracy of both techniques for the detection of partial-thickness and full-thickness rotator cuff tears (RCT).

Methods

In 4 years, 5,216 patients underwent US by experienced musculoskeletal radiologists. Retrospectively, patient records were evaluated if MRI and surgery were performed within 5 months of US. US and MRI findings were classified into intact cuff, partial-thickness and full-thickness RCT, and were correlated with surgical findings.

Results

Additional MR imaging was performed in 275 (5.2%) patients. Sixty-eight patients underwent surgery within 5 months. US and MRI correctly depicted 21 (95%) and 22 (100%) of the 22 full-thickness tears, and 8 (89%) and 6 (67%) of the 9 partial-thickness tears, respectively. The differences in performance of US and MRI were not statistically significant (p?=?0.15).

Conclusions

MRI following routine shoulder US was requested in only 5.2% of the patients. The additional value of MRI was in detecting intra-articular lesions. In patients who underwent surgery, US and MRI yielded comparably high sensitivity for detecting full-thickness RCT. US performed better in detecting partial-thickness tears, although the difference was not significant.  相似文献   

10.

Purpose

The purpose of this study was to analyse the natural course of symptomatic full-thickness and partial-thickness rotator cuff tears treated non-operatively and to identify risk factors affecting tear enlargement.

Methods

One hundred and twenty-two patients who received non-surgical treatment for a partial- or full-thickness supraspinatus tear were included in this study. All rotator cuff tears were diagnosed with magnetic resonance imaging (MRI), and the same modality was used for follow-up studies. Follow-up MRI was performed after at least a 6-month interval. We evaluated the correlation between tear enlargement and follow-up duration. Eleven risk factors were analysed by both univariate and multivariate analyses to identify factors that affect enlargement of rotator cuff tears. The mean follow-up period was 24.4 ± 19.5 months.

Results

Out of 122 patients, 34 (27.9%) patients had an initial full-thickness tear and 88 (72.1%) patients had a partial-thickness tear. Considering all patients together, tear size increased in 51/122 (41.8%) patients, was unchanged in 65/122 (53.3%) patients, and decreased in 6/122 (4.9%) patients. Tear size increased for 28/34 (82.4%) patients with full-thickness tears and 23/88 (26.1%) patients with partial-thickness tears. From the two groups which were followed over 12 months, a higher rate of enlargement was observed in full-thickness tears than in partial-thickness tears (6–12 months, n.s.; 12–24 months, P = 0.002; over 24 months, P < 0.001). Logistic regression revealed that having a full-thickness tear was the most reliable risk factor for tear progression (P < 0.001).

Conclusions

This study found that 28/34 (82.4%) of symptomatic full-thickness rotator cuff tears and 23/88 (26.1%) of symptomatic partial-thickness tears increased in size over a follow-up period of 6–100 months. Full-thickness tears showed a higher rate of enlargement than partial-thickness tears regardless of the follow-up duration. Univariate and multivariate analyses suggested that full-thickness tear was the most reliable risk factor for tear enlargement. The clinical relevance of these observations is that full-thickness rotator cuff tears treated conservatively should be monitored more carefully for progression than partial-thickness tears.

Level of evidence

IV.
  相似文献   

11.
PURPOSE: To evaluate prospectively the accuracy of indirect magnetic resonance (MR) arthrography for supraspinatus tendon tears during neutral positioning or abduction and external rotation (ABER) and neutral positioning. MATERIALS AND METHODS: Informed consent was obtained in all patients, and the study was approved by the institutional review board. Indirect MR arthrography of the shoulder was performed in 51 symptomatic patients (14 female, 37 male; mean age, 47 years) in the neutral position (set 1) and in the neutral and ABER positions (set 2). Two readers independently interpreted both sets, and diagnoses were compared with arthroscopic findings. Diagnostic accuracy was calculated, and 95% confidence intervals were used to detect significant differences between sets. Diagnostic confidence was recorded by using a three-level confidence score. Differences between sets were evaluated by using the Wilcoxon signed rank test. Interobserver agreement was determined separately for each set and for all diagnoses, full-thickness tears, and partial-thickness tears. RESULTS: For full-thickness tears, there was no benefit to reading set 2. For reader 1, sensitivity and specificity were 95% and 100%, respectively, for set 1 and 100% and 100%, respectively, for set 2. For reader 2, sensitivity and specificity were 80% and 100%, respectively, for set 1 and 100% and 100%, respectively, for set 2. For partial-thickness tears, sensitivity was significantly higher after reading set 2. For reader 1, sensitivity and specificity were 71% and 88%, respectively, for set 1 and 93% and 100%, respectively, for set 2. For reader 2, sensitivity and specificity were 50% and 88%, respectively, for set 1 and 86% and 94%, respectively, for set 2. For both readers, diagnostic confidence for partial-thickness tears was significantly higher after reading set 2. After the interpretation of set 2, kappa values increased from 0.35 to 1.00 for full-thickness tears and from 0.12 to 0.63 for partial-thickness tears. CONCLUSION: Indirect MR arthrography with supplementary images obtained with patients in the ABER position significantly improved sensitivity and increased diagnostic confidence for partial-thickness tears of the supraspinatus tendon. Interobserver agreement was improved for both full- and partial-thickness tears.  相似文献   

12.

Objective

To assess the diagnostic performance of MR arthrography in the diagnosis of the various types of partial-thickness rotator cuff tears by comparing the MR imaging findings with the arthroscopic findings.

Materials and Methods

The series of MR arthrography studies included 202 patients consisting of 100 patients with partial-thickness rotator cuff tears proved by arthroscopy and a control group of 102 patients with arthroscopically intact rotator cuffs, which were reviewed in random order. At arthroscopy, 54 articular-sided, 26 bursal-sided, 20 both articular- and bursal-sided partial-thickness tears were diagnosed. The MR arthrographies were analyzed by two radiologists for articular-sided tears, bursal-sided tears, and both articular- and bursal-sided tears of the rotator cuff. The sensitivity and specificity of each type of partial-thickness tears were determined. Kappa statistics was calculated to determine the inter- and intra-observer agreement of the diagnosis of partial-thickness rotator cuff tears.

Results

The sensitivity and specificity of the various types of rotator cuff tears were 85% and 90%, respectively for articular-sided tears, 62% and 95% for bursal-sided tears, as well as 45% and 99% for both articular- and bursal-sided tears. False-negative assessments were primarily observed in the diagnosis of bursal-sided tears. Conversely, both articular- and bursal-sided tears were overestimated as full-thickness tears. Inter-observer agreement was excellent for the diagnosis of articular-sided tears (k = 0.70), moderate (k = 0.59) for bursal-sided tears, and fair (k = 0.34) for both articular- and bursal-sided tears, respectively. Intra-observer agreement for the interpretation of articular- and bursal-sided tears was excellent and good, respectively, whereas intra-observer agreement for both articular- and bursal-sided tears was moderate.

Conclusion

MR arthrography is a useful diagnostic tool for partial-thickness rotator cuff tears, but has limitations in that it has low sensitivity in bursal- and both articular- and bursal-sided tears. In addition, it shows only fair inter-observer agreement when it comes to predicting both articular- and bursal-sided tears.  相似文献   

13.

Objective

To determine the accuracy of MR imaging for the evaluation of the subscapularis tendon as well as define imaging findings that will increase accuracy.

Materials and methods

Retrospective review of the MR and operative (OR) reports of 286 patients was conducted and reviewed for the presence/degree (partial (PT)/full-thickness (FT)) of tearing; only PT articular tears were included. The presence of a supraspinatus tear and time interval between surgery and MRI were also documented. All of the PT tears called on MRI were also reviewed to see if there was a statistically significant association between certain imaging characteristics and the presence of a tear in surgery. Statistical analysis included 95 % confidence intervals, Fisher’s exact, and exact Mann–Whitney tests.

Results

A total of 244 patients were included in the study with a total of 25 subscapularis tears, 16 PT and nine FT, and 219 intact tendons in arthroscopy; 20/25 tears and 200 intact tendons were diagnosed correctly on MRI, resulting in sensitivity of 80 %, specificity of 91 %, accuracy of 90 %, positive predictive value of 51 %, and negative predictive value of 98 %. There was a significant association between the presence of a PT tear during arthroscopy and fluid-like signal within the tendon on more than one imaging plane (p?<?0.001) with an accuracy of 90 %.

Conclusions

This study reflects a musculoskeletal radiology section’s experience with the diagnosis of subscapularis tendon pathology, demonstrating that MRI could be used to accurately evaluate the subscapularis tendon. An understanding of certain imaging pitfalls and the presence of fluid-like signal on multiple imaging planes should increase the diagnostic accuracy of the radiologist evaluating the subscapularis tendon for the presence of a tear.  相似文献   

14.
PURPOSE: To assess the practical utility of isotropic shoulder imaging in patients undergoing MR arthrography. Isotropic shoulder imaging can be performed in less than three minutes with use of fast gradients. MATERIALS AND METHODS: Two experienced musculoskeletal radiologists retrospectively interpreted MR images of the shoulder in 100 consecutive patients undergoing MR arthrography of the shoulder. All patients underwent MRI of the shoulder in oblique coronal, oblique sagittal, and axial planes on a 3.0-Tesla MRI system. All patients had conventional fast spin-echo T1-weighted imaging. All patients also had thin section (0.4 mm) isotropic spoiled gradient echo images performed. A total of 67 of the 100 patients underwent subsequent arthroscopy and results were compared with MR interpretations. RESULTS: There were 41 full-thickness supraspinatus tendon tears, nine partial-thickness supraspinatus tendon tears (seven articular surface and two bursal surface), 21 superior labral, 18 anterior labral, and seven posterior labral tears demonstrated by consensus retrospective reading of the 100 shoulder MR exams. There was no difference in interpretation of the isotropic images as compared to the conventionally acquired images in the oblique coronal, oblique sagittal, and axial planes. Some patients had more than one finding on each exam. A total of 67 patients went on to arthroscopy. There were 41 full-thickness supraspinatus tendon tears, nine partial-thickness supraspinatus tendon tears, 21 superior labral, 18 anterior labral, and seven posterior labral tears demonstrated on arthroscopy. All full- and partial-thickness supraspinatus tendon tears seen at arthroscopy were seen on consensus MR reading. A total of 19 out of the 21 patients with superior labral anterior posterior (SLAP) tears at arthroscopy were seen on consensus MR reading. A total of 16 of the 18 anterior labral tears and six of the seven posterior labral tears seen at arthroscopy were seen on consensus MR reading. Some of the 67 patients had more than one finding on arthroscopy. CONCLUSION: Isotropic imaging of the shoulder is practical in clinical imaging when performed with use of fast gradients on a 3-Tesla system. Isotropic imaging provides the same clinical information as conventional imaging and can be acquired in less than three minutes.  相似文献   

15.

Purpose

No studies have used stress analysis with finite element analysis (FEA) to determine the causes of and mechanisms underlying rotator cuff tears. Therefore, we performed a biomechanical evaluation of the changes in stress distribution on the rotator cuff using three-dimensional (3-D) FEA.

Methods

The 3-D FEA model of shoulder joint allowed for abduction angles of 0°, 45° and 90° from the plane of the scapula and included the anatomical insertion points of the three major rotator cuff tendons and the middle fibres of the deltoid muscle. Stress distribution of the supraspinatus tendon on 3-D FEA was validated by a comparison with cadaveric and two-dimensional finite element model.

Results

The principal stress peaked in the region approximately 1 cm proximal to the insertion of the supraspinatus tendon. Furthermore, the stress on the joint side increased at the anterior edge of the supraspinatus tendon at abduction angles of 45° and 90°.

Conclusion

There are differences in stress changes between the joint side and bursal side of the supraspinatus tendon within the angles of abduction. The maximal tensile stress was observed on the articular side of the anterior edge of the supraspinatus tendon at 90° abduction. Our results indicate that the difference in tensile stress between the two layers results in delamination and causes partial-thickness tears.

Level of evidence

Decision analysis, Level II.  相似文献   

16.

Purpose

To retrospectively characterize the ultrasound appearance of displaced ulnar collateral ligament (UCL) tears that are proven at surgery, and then determine the accuracy of the resulting ultrasound criteria in differentiating displaced from non-displaced UCL tears.

Materials and methods

After institutional review board approval, 26 patients were identified from the radiology information system over a 10-year period that had ultrasound evaluation of the thumb and surgically proven UCL tear. Retrospective review of the displaced full-thickness tears was carried out to characterize displaced tears and to establish ultrasound criteria for such tears. A repeat retrospective review 4 months later of all UCL tears applied the criteria to determine accuracy of ultrasound in the diagnosis of displaced full-thickness UCL tear.

Results

The 26 subjects consisted of 17 displaced full-thickness UCL tears, seven non-displaced full-thickness tears, and two partial-thickness tears at surgery. Retrospective ultrasound review of displaced full-thickness tears identified two criteria present in all cases: non-visualization of the UCL ligament and presence of a heterogeneous mass-like area proximal to the first metacarpophalangeal joint. Applying these criteria at the second retrospective review resulted in 100 % sensitivity, specificity, positive predictive value, negative predictive value, and accuracy.

Conclusions

The ultrasound findings of absent UCL fibers and presence of a heterogeneous mass-like abnormality proximal to the first metacarpophalangeal joint achieved 100 % accuracy in differentiating displaced from non-displaced full-thickness UCL tear of the thumb. Displaced full-thickness UCL tears most commonly were located proximal to the adductor aponeurosis.  相似文献   

17.

Objective

The purpose of this study was first, to determine the sensitivity, specificity, and accuracy of MDCT arthrography (CTA) for the diagnosis of acetabular labral tear and sulcus; second, to correlate tear types using the Lage classification system on CTA compared with the arthroscopic classification; and third, to correlate CTA localization with arthroscopic localization.

Materials and methods

Direct CTA was performed using 16- or 64-slice MDCT in 126 hips (124 patients) who had chronic groin pain and positive impingement test. Images were reviewed and evaluated by two experienced musculoskeletal radiologists preoperatively. CTA findings were compared with arthroscopic findings in 58 hips (56 patients) under consensus by two orthopedic surgeons.

Results

Forty-one of the 58 hips were diagnosed as labral tears on CT arthrography. Forty-three of the 58 hips were shown to have a labral tear on arthroscopy. Sensitivity, specificity, and accuracy for detecting labral tear and sulcus by CTA were 90.7%, 86.7%, and 89.7%, and 93.8%, 97.6% and 96.6% respectively for observer 1, and 90.7% and 80.0%, 87.9% and 87.5%, 95.2%, and 93.1 % respectively for observer 2. Thirty-five out of 41 hips (85%) that were diagnosed with labral tear on CTA correlated substantially with arthroscopic Lage classification (kappa coefficient = 0.65). CTA and arthroscopic findings showed similar distribution patterns of the tears with most lesions located in antero- and postero-superior areas (p?=?0.013).

Conclusion

Direct CT arthrography using MDCT may be a useful diagnostic technique in the detection of acetabular labral tear.  相似文献   

18.

Purpose

This study aimed to evaluate the diagnostic possibilities of MR arthrography in the correct identification of complex tears of the biceps pulley and their possible correlation with anterosuperior impingement (ASI) development.

Materials and methods

MR arthrography examinations of 23 athletes with clinical suspicion of ASI were reviewed. All examinations were obtained with a 1.5-T unit (Signa Horizon, GE Healthcare). The shoulders were studied with a dedicated surface coil with the patient’s arm in the neutral position and in internal and external rotation. In five patients, images in abduction-external rotation (ABER) were obtained. Within 2 month after MR arthrography, the athletes underwent arthroscopic surgery.

Results

MR arthrography images showed a spectrum of tears that, according to the Habermeyer classification, were subdivided into four groups: type 1 in three patients; type 2 in five; type 3 in seven; type 4 in eight. At arthroscopic evaluation, one patient presented type 1 lesion, five type 2, five type 3 and ten type 4. During arthroscopic dynamic manoeuvres, ASI signs were observed in three patients with type 3 lesion and in ten with type 4 lesion.

Conclusions

MR arthrography is the imaging modality of choice for evaluating lesions of the rotator interval structures, and only complex lesions of the biceps pulley are related to the development of ASI.  相似文献   

19.

Objective

Humeral avulsion of the glenohumeral ligament (HAGL) is an uncommon shoulder injury. We report the prevalence of HAGL lesions and other associated shoulder injuries in a large series of shoulder MR examinations. All results were correlated with surgery.

Materials and methods

MR reports of 1,000 consecutive conventional shoulder MR exams performed on patients with shoulder pain were reviewed in our information system for the word HAGL. A total of 743 patients went on to surgery. There were 23 HAGL lesions reported at surgery. Those 23 examinations were reviewed retrospectively in consensus by two musculoskeletal radiologists. Scans were assessed for HAGL lesions, full or partial thickness supraspinatus, infraspinatus or subscapularis tendon tears, superior labral anterior posterior (SLAP) tears, anterior or posterior labral tears, and Hill–Sachs lesions.

Results

All 23 patients had HAGL lesions at surgery. Sixteen HAGL lesions were seen on prospective MR reading and 17 HAGL lesions were seen on retrospective MR consensus reading. Six HAGL lesions were not seen on retrospective consensus reading. Sixteen patients had Hill–Sachs deformities, ten had subscapularis tendon tears, five had supraspinatus tendon tears, six had superior labral tearing, and six had anterior labral tears. The above findings were confirmed on arthroscopy.

Conclusions

In this series, there was a 1.6 % prevalence on all MR examinations, and prevalence of 2.1 % seen on MR examination for those who went to surgery. Common injuries associated with HAGL lesions are Hill–Sachs deformities and subscapularis tendon tears. Anterior labral tears were seen in only six cases despite Hill–Sachs deformities in 16 patients. In patients with Hill–Sachs deformities without anterior labral tears, one must carefully assess for the presence of a HAGL lesion.  相似文献   

20.
The aim of this study was to compare the diagnostic reliability of US with MR arthrography in diagnosing supraspinatus tendon tears. Surgical findings were used as the gold standard in detecting tears. A total of 44 patients were assessed with transverse and longitudinal US scans with respect to the long axis of the rotator cuff tendons and then examined with MR arthrography. This technique involved free-hand injection of contrast medium into the shoulder joint. At surgery 20 incomplete and 24 complete tears were observed. Ultrasound offered good results for the large tears, but its sensitivity decreased proportionally with the size of the tears. Magnetic resonance arthrography correctly diagnosed 43 tears, whereas only one false-negative diagnosis of tendinosis was made for a partial tear on the bursal side. Since it improves the diagnosis of small tears, MR arthrography must be performed on all patients for whom surgical repair is necessary in order to restore normal functions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号