Background

Leaks occurring after weight loss operations constitute a therapeutic challenge. There is no consensus as to what comprises state-of-the-art management of leaks after bariatric surgery. We sought to determine the efficacy and possible adverse effects of endoluminal stenting for leaks after bariatric surgery.

Methods

We report our experience with the stent treatment of consecutive bariatric patients with a leak (retrospective cohort study). Between October 2005 and July 2010, 47 patients presented an acute leak after a bariatric procedure (61 % primary procedures, 39 % revisions). Fifteen patients were initially approached laparoscopically, and 32 were treated by nonoperative techniques. After adequate drainage and resuscitation, all 47 patients were treated by the endoscopic placement of a partially covered metallic stent, and later of a plastic stent inside the metallic prosthesis to facilitate removal. Both stents were then ablated 1 week later. Primary outcome measurement concerned healing of the fistula, as evidenced by radiographic imaging. Secondary outcomes were length of hospital stay and occurrence of peri- and postprocedural complications.

Results

There was no mortality. 41 patients (87.23 %) healed with stent treatment alone; 5 of the 6 persisting leaks healed with laparoscopic intervention (intention-to-treat success rate 96 %). Complication rate was 28.7 %. Length of hospital stay was mean ± standard deviation 22.4 ± 19.38 days for the patients treated by stent alone, and 23.4 ± 18.4 days for the patients requiring additional surgery (P = NS). One patient developed a stricture and required endoscopic dilation, and one is still awaiting surgical treatment.

Conclusions

Leaks after bariatric surgery can be treated safely and effectively by endoscopic stents. In cases of persisting leaks, laparoscopic intervention is successful in a majority of cases. Late strictures seldom occur.  相似文献   

2.

Background

Leaks of the esophagus are associated with a high mortality rate and need to be treated as soon as possible. Therapeutic options are surgical repair or resection or conservative management with cessation of oral intake and antibiotic therapy. We evaluated an alternative approach that uses self-expandable metallic stents (SEMS).

Methods

Between 2002 and 2007, 31 consecutive patients with iatrogenic esophageal perforation (n = 9), intrathoracic anastomotic leak after esophagectomy (n = 16), spontaneous tumor perforation (n = 5), and esophageal ischemia (n = 1) were treated at our institution. All were treated with endoscopic placement of a covered SEMS. Stent removal was performed 4 to 6 weeks after implantation. To exclude continuous esophageal leak after SEMS placement, radiologic examination was performed after stent implantation and removal.

Results

SEMS placement was successful in all patients and a postinterventional esophagogram demonstrated full coverage of the leak in 29 patients (92%). In two patients, complete sealing could not be achieved and they were referred to surgical repair. Stent migration was seen in only one patient (3%). After removal, a second stent with larger diameter was placed and no further complication occurred. Two patients died: one due to myocardial infarction and one due to progressive ischemia of the esophagus and small bowl as a consequence of vascular occlusion. Stent removal was performed within 6 weeks, and all patients had radiologic and endoscopic evidence of esophageal healing.

Conclusions

Implantation of covered SEMS in patients with esophageal leak or perforation is a safe and feasible alternative to operative treatment and can lower the interventional morbidity rate.  相似文献   

3.

Introduction

The use of self-expandable stents to treat postoperative leaks and fistula in the upper gastrointestinal (GI) tract is an established treatment for leaks of the upper GI tract. However, lumen-to-stent size discrepancies (i.e., after sleeve gastrectomy or esophageal resection) may lead to insufficient sealing of the leaks requiring further surgical intervention. This is mainly due to the relatively small diameter (≤30 mm) of commonly used commercial stents. To overcome this problem, we developed a novel partially covered stent with a shaft diameter of 36 mm and a flare diameter of 40 mm.

Methods

From September 2008 to September 2010, 11 consecutive patients with postoperative leaks were treated with the novel large diameter stent (gastrectomy, n = 5; sleeve gastrectomy, n = 2; fundoplication after esophageal perforation, n = 2; Roux-en-Y gastric bypass, n = 1; esophageal resection, n = 1). Treatment with commercially available stents (shaft/flare: 23/28 mm and 24/30 mm) had been unsuccessful in three patients before treatment with the large diameter stent. Due to dislocation, the large diameter stent was anchored in four patients (2× intraoperatively with transmural sutures, 2× endoscopically with transnasally externalized threads).

Results

Treatment was successful in 11 of 11 patients. Stent placement and removal was easy and safe. The median residence time of the stent was 24 (range, 18–41) days. Stent dislocation occurred in four cases (36 %). It was treated by anchoring the stent. Mean follow-up was 25 (range, 14–40) months. No severe complication occurred during or after intervention and no patient was dysphagic.

Conclusions

Using the novel large diameter, partially covered stent to seal leaks in the upper GI tract is safe and effective. The large diameter of the stent does not seem to injure the wall of the upper GI tract. However, stent dislocation sometimes requires anchoring of the stent with sutures or transnasally externalized threads.  相似文献   

4.

Background

Few clinical studies to date have compared different types of self-expandable metallic stents (SEMS) and their outcomes in patients with pure duodenal obstruction caused by pancreaticobiliary cancer. The aim of this study was to compare the clinical effectiveness and side effects of uncovered and covered SEMS for the palliation of duodenal obstruction caused by pancreaticobiliary cancer.

Methods

We retrospectively analyzed all patients with pancreaticobiliary cancer who underwent upper endoscopy with SEMS placement for malignant duodenal obstruction at the National Cancer Center of Korea between April 2003 and December 2010. The technical and clinical success rates of the procedure, complications, and durations of stent patency and overall survival were evaluated.

Results

We identified 70 patients with a mean age of 51.2 years (range = 39–81 years); of these, 46 (65.7 %) had pancreatic cancer, 9 (12.9 %) had bile duct cancer, 11 (15.7 %) had gallbladder cancer, and 4 (5.7 %) had cancer of the ampulla of Vater. Twenty-four patients (34.3 %) received covered SEMSs and 46 (65.7 %) received uncovered SEMSs. Technical and clinical success rates were similar for the covered and uncovered stent groups. The complication rate was higher in the covered than in the uncovered group (62.5 vs. 34.8 %, P = 0.025), due primarily to a significantly higher stent migration rate (20.8 vs. 0 %, P = 0.004). Perforation as a late complication occurred in four patients, two in each group (8.3 vs. 4.3 %, P = 0.425). Stent patency tended to be shorter for covered than for uncovered duodenal stents (13.7 ± 8.6 weeks vs. not reached, P = 0.069).

Conclusions

The use of uncovered stents may be a preferred option for duodenal obstruction secondary to pancreaticobiliary malignancies, since they were effective in preventing stent migration and tended to have longer patency than covered stents. Careful attention should be paid to signs and symptoms of perforation during follow-up.  相似文献   

5.

Background

Anastomotic leakages are severe complications of upper gastrointestinal surgery with serious morbidity and mortality. Until recently, only abscess drainage was possible. Since 2007, removable and repositionable covered metal self-expandable stents (RReCoMSeS) have been used in our hospital to cover leaks.

Methods

Patients with postsurgical gastrointestinal leaks treated with RReCoMSeS between January 2007 and March 2010 were retrospectively evaluated and described.

Results

Twenty-six patients were treated with RReCoMSeS (totally covered Choo/Hanaro and partially covered Endoflex stents). Included patients had anastomotic leaks after esophagectomy (15) and bariatric surgery (11). Overall successful sealing of the leak occurred in 81 % (including multiple procedures). In total 33 RReCoMSeS were used (mean 1.3 stents and 1.7 procedures per patient). Twenty-one of 33 RReCoMSeS succeeded in sealing the leak (64 %). Migration occurred in 24 % RReCoMSeS, and 9 % disintegrated. One stent (3 %) caused a perforation.

Conclusions

RReCoMSeS are a safe alternative for treating postsurgical leaks in the upper gastrointestinal tract. In 81 % of patients and with 64 % of the inserted stents, leaks were sealed successfully, with few complications. Fewer stents per patient were needed thanks to their repositionability. Stent migration is a major problem.  相似文献   

6.

Background

The use of self-expandable metal stents (SEMS) for the treatment of malignant colorectal obstruction is increasing. However, results of risk factors for its complications are inconsistent. This study aimed to examine the clinical effectiveness of the procedure as well as the complications and risk factors associated with the complications.

Methods

Medical records of patients with malignant colorectal obstruction who underwent endoscopic placement of covered or uncovered SEMS were reviewed retrospectively. The procedure was performed by two endoscopists with experience in pancreatobiliary endoscopy.

Results

A total of 152 patients were included (102 men; mean age, 70 ± 12.5 years). The procedure was performed for palliative management in 83 patients and performed as a bridge to surgery in 69 patients. There were 111 uncovered stents and 41 covered stents. The technical success rate was 100 % and the clinical success rate 94.1 %. Overall complications were observed in 49 patients (32.2 %) during the follow-up period (median, 98 days; interquartile range, 19–302 days). Obstruction (17.1 %), migration (7.9 %), perforation (5.2 %), bleeding (1.3 %), and tenesmus (0.7 %) were the causes of the complications. Stage IV disease, carcinomatosis peritonei, complete obstruction of the colon, palliative intention, and covered stents increased the complications based on the univariate analysis. Multivariate analysis revealed that complete obstruction of the colon and covered stents were significantly independent risk factors for complications. In the palliative group, Kaplan–Meier analysis showed significantly shorter median duration to the onset of complications in the covered stent group than in the uncovered stent group.

Conclusions

Although SEMS in patients with malignant colorectal obstruction is effective both as palliative therapy and as a bridge to surgery, one-third of patients experienced complications. Severity of obstruction and stent type can influence outcomes.  相似文献   

7.

Background

Laparoscopic sleeve gastrectomy has become a very frequent procedure in bariatric surgery due to its efficacy and simplicity compared to gastric bypass. Gastric staple line leak (1 to 7 % of cases) is a severe complication with a long nonstandardized treatment. The aim of this retrospective study was to examine the success and tolerance of covered stents in its management.

Methods

From January 2009 to December 2011, nine patients with gastric staple line leaks after sleeve gastrectomy were treated with covered stents in our department (seven referred from other institutions). The leaks were diagnosed by CT scan and visualized during the endoscopy. Among the studied variables were operative technique, post-operative fistula diagnosis delay, stent treatment delay, and stent tolerance. In our institution, Hanarostent® (length 17 cm, diameter 18 mm; M.I. Tech, Seoul, Korea) was used and inserted under direct endoscopic control.

Results

Stent treatment was successful in seven cases (78 %). Two other cases had total gastrectomy (405 and 185 days after leak diagnosis). Early stent removal (due to migration or poor tolerance) was necessary in three cases. The average stent treatment duration was of 6.4 weeks, and the average healing time was 141 days. The five patients with an early stent treatment (≤3 weeks after leak diagnosis) had an average healing time of 99 days versus 224 for the four others.

Conclusions

Covered self-expandable stent is an effective treatment of gastric leaks after sleeve gastrectomy. Early stent treatment seems to be associated with shorter healing time.  相似文献   

8.

Background

Self-expandable metal stents (SEMS) and self-expandable plastic stents (SEPS) maybe used for the treatment of benign upper gastrointestinal (GI) leaks and strictures. This study reviewed our experience with stent insertions in patients with benign upper GI conditions.

Methods

Patients who underwent stent placement for benign upper GI strictures and leaks between March 2007 and April 2011 at a tertiary referral academic center were studied using an endoscopic database and electronic patient records. The technical success, complications, and clinical improvement after stent removal were compared according to type of stent. The outcomes measured were clinical response, adverse events, and predictors of stent migration.

Results

Thirty-eight patients (50 % male, mean age = 54 years, range = 12–82) underwent 121 endoscopic procedures. Twenty patients had stents placed for strictures, and 18 had stents placed for leaks. Stent placement was technically successful in all patients. The average duration of stent placement was 54 days (range = 18–118). Clinical improvement immediately after stent placement was seen in 29 of the 38 patients (76.3 %). Immediate post-procedure adverse events occurred in 8 patients. Late adverse events were seen in 18 patients. Evidence of stent migration occurred in 16 patients and was seen in 42 of the 118 successfully placed stents (35.5 %). Migration was more frequent with fully covered SEMS (p = 0.002). After stent removal, 27 patients were evaluable for long-term success (median follow-up time of 283 days, IQR 38–762). Resolution of strictures or leaks was seen in 11 patients (40.7 %). Predictors for long-term success included increasing age and if the stent did not cross the GE junction.

Conclusions

Placement of SEPS and SEMS for benign refractory strictures and fistulas has modest long-term clinical efficacy and is limited by a significant migration rate. Stent migration is common and frequent with fully covered SEMS compared to other types of stents, regardless of indication or location.  相似文献   

9.

Background

Fully covered esophageal self-expandable metallic stents (SEMS) often are used for palliation of malignant dysphagia. However, experience and data on these stents are still limited. The purpose of this multicenter study was to evaluate the efficacy and safety of fully covered nitinol SEMS in patients with malignant dysphagia.

Methods

37 patients underwent placement of a SEMS during a 3?year period. Five patients underwent SEMS placement as a bridge to surgery: one for tracheoesophageal fistula in the setting of squamous cell carcinoma of the esophagus, one for perforation in setting of esophageal adenocarcinoma, 27 for unresectable esophageal cancer (16 adenocarcinoma, 11 squamous cell carcinoma), two for lung cancer, and one for breast-cancer-related esophageal strictures.

Results

SEMS placement was successful in all 37 patients. Immediate complications after stent deployment included chest pain (n?=?6), severe heartburn (n?=?1), and upper gastrointestinal bleeding requiring SEMS revision (n?=?1). Dysphagia scores improved significantly from 3.2?±?0.4 before stent placement to 1.4?±?1.0 at 1?month (P?P?P?=?0.0018) at 6?months. The stent was removed in 11 patients (30%) for the following indications: resolution of stricture (n?=?3), stent malfunction (n?=?5), and stent migration (n?=?3). After stent removal, three patients were restented, three underwent dilation, and two underwent PEG placement. Mean survival for the 37 patients after stent placement was 146.3?±?143.6 (range, 13–680) days.

Conclusions

Our study suggests that fully covered SEMS placement improve dysphagia scores in patients with malignant strictures, particularly in the unresectable population. Further technical improvements in design to minimize long-term malfunction and migration are required.  相似文献   

10.
Park JK  Lee MS  Ko BM  Kim HK  Kim YJ  Choi HJ  Hong SJ  Ryu CB  Moon JH  Kim JO  Cho JY  Lee JS 《Surgical endoscopy》2011,25(4):1293-1299

Background

Self-expandable metallic stents (SEMS) of varying designs and materials have been developed to reduce complications, but few comparative data are available with regard to the type of stent and the stent manufacturer. We analyzed the success rates and complication rates, according to stent type (uncovered vs. covered stent) and individual stent manufacturer, in malignant colorectal obstruction.

Methods

From November 2001 to August 2008, 103 patients were retrospectively included in this study: four types of uncovered stents in 73 patients and two types of covered stents in 30 patients. The SEMS was inserted into the obstructive site by using the through-the-scope method.

Results

Technical and clinical success rates were not different between stent type or among stent manufacturers: 100 and 100% (p?=?ns) and 100 and 96.6% (p?>?0.05), respectively, in uncovered and covered stents. Stent occlusion and migration rates were 12.3 and 3.3% (p?=?0.274) and 13.7 and 16.7% (p?=?0.761), respectively, in uncovered and covered stents, and 11.1, 5, and 9% (p?=?0.761) and 25.9, 15, and 0% (p?=?0.037) in Wallstent, Niti-S, and Bonastent uncovered stents, respectively.

Conclusions

The placement of SEMS is an effective and safe treatment for patients with malignant colorectal obstruction. Although minor differences in outcome were detected according to the type and the manufacturer of the stents, no statistically significant difference was observed, except in stent migration among the stent manufacturer.  相似文献   

11.

Background

The covered metallic stent is effective for managing malignant distal biliary obstructions. The most popular covered metallic stent is the covered Wallstent (CWS). This study estimated the efficacy and safety of a new expanded polytetrafluoroethylene (e-PTFE)-covered nitinol metallic stent, the ComVi stent. This covered metallic stent consists of an e-PTFE membrane sandwiched between two uncovered metallic stents with weak axial (straightening) force. Wire is exposed on both the inner and outer surfaces.

Methods

Between May 2005 and April 2007, ComVi stents were placed consecutively in 47 patients with unresectable malignant distal biliary obstruction. The cases involved 35 pancreatic cancers, 8 metastatic nodes, 2 gallbladder cancers, and 2 bile duct cancers. The patients were compared with 47 patients who received CWS placement between August 2001 and May 2005 matched for age, sex, and causative disease from 133 cases.

Results

No significant differences in stent patency or patient survival were found. Stent occlusion was observed in 13 patients (27.7%) in the ComVi group and 10 patients (21.3%) in the CWS group. The cause of occlusion in both groups was tumor overgrowth (4.25% vs 4.2%), sludge (8.5% vs 6.3%), impaction of food scraps (14.9% vs 2.1%), and bile duct kinking (0% vs 8.4%). Other complications were migration (2.1% vs 17.0%; p = 0.0304) and cholecystitis (2.1% vs 6.3%), and there were significant differences in the incidence of complications except for occlusion (4.2% vs 24.6%; p = 0.0142).

Conclusion

The ComVi stent has a patency similar to that of the CWS and a lower incidence of migration. However, early occlusion by food impaction was increased and should be resolved.  相似文献   

12.

Background

Fully covered self-expanding metal stents (FCSEMS), unlike partially covered SEMS (PCSEMS), have been used to treat benign as well as malignant conditions. We aimed to evaluate the outcome of PCSEMS and FCSEMS in patients with both benign and malignant esophageal diseases.

Methods

Data were reviewed of all patients who underwent SEMS placement for malignant or benign conditions between January 1995 and January 2012. Patients with cancer were followed for at least 3 months, until death or surgery. Patients with benign conditions had stents removed between 4 and 12 weeks. Patient demographics, location and type of lesion, stent placement and removal, clinical success, and adverse events were analyzed.

Results

A total of 252 patients (mean ± standard deviation age 68.5 ± 14 years; 171 male) received 321 SEMS (209 PCSEMS, 112 FCSEMS) for malignant (78 %) and benign (22 %) conditions. Stent placement and removal was successful in 97.6 and 95.6 % procedures. Successful relief of malignant dysphagia was noted in 140 of 167 patients (83.8 %) and control of benign fistulas, leaks, and perforations was noted in 21 of 25 patients (84 %), but only 8 of 15 patients (53 %) with recalcitrant benign strictures had effective treatment. Fifty-six patients (22.2 %) experienced at least one stent-related adverse events. Migration was frequent, occurring in 61 of 321 stent placements (19 %), and more frequently with FCSEMS than PCSEMS (37.5 vs. 9.1 %, p < 0.001). FCSEMS, benign conditions, and distal location were the variables independently associated with migration (p < 0.001, p = 0.022, and p = 0.008). Patients with PCSEMS were more likely to have tissue in- or overgrowth than FCSEMS (53.4 vs. 29.1 %, p = 0.004).

Conclusions

Both PCSEMS and FCSEMS can be used in benign and malignant conditions; they are both effective for relieving malignant dysphagia and for closing leaks and perforations, but they seem less effective for relieving benign recalcitrant strictures. Stent migration is more common with FCSEMS, which may limit its use for the palliation of malignant dysphagia.  相似文献   

13.

Purpose

The purpose of this study was to assess the technical feasibility and clinical effectiveness of expandable metallic stent placement in 196 patients with recurrent malignant obstruction in their surgically altered stomach.

Methods

The 196 patients were treated using five different types of gastric surgery performed for gastric cancer: total gastrectomy (type 1) in 73 patients; distal gastrectomy with gastroduodenostomy (type 2) in 39 patients; distal gastrectomy with a Roux-en-Y gastrojejunostomy (type 3) in 21 patients; distal gastrectomy with a gastrojejunostomy (type 4) in 49 patients; and palliative gastrojejunostomy for unresectable gastric cancer (type 5) in 14 patients. The technical and clinical success rates, complications, dysphagia score, and influence of chemotherapy were evaluated and the complications compared between the two stent types. The overall survival and stent patency were calculated using the Kaplan–Meier method.

Results

Stent placement was technically successful in 192 of 196 patients (97.9 %), with 184 of the 192 patients (95.8 %) showing symptomatic improvement. The mean dysphagia score improved from 3.24 ± 0.64 to 1.48 ± 0.82 (p < 0.001). The complication rate was 25 %. The incidence of stent migration was significantly higher in fully covered stents and in patients who underwent chemotherapy (p < 0.001 and p = 0.005, respectively). Chemotherapy was significantly associated with an increase of survival (p < 0.001). The median survival and stent patency were 131 and 90 days, respectively.

Conclusion

Placement of expandable metallic stents in patients with recurrent cancer after a surgically altered stomach is technically feasible and clinically effective. Chemotherapy was associated with increased stent migration and prolonged survival.  相似文献   

14.

Background

The purpose of this study is to report our initial experience with a new fully covered metallic stent with a novel design (AXIOS) to prevent migration and fluid leakage, in the drainage of pancreatic fluid collections (PFC).

Methods

We included nine patients from four Spanish centers undergoing endoscopic ultrasound (EUS)-guided drainage of PFC with placement of an AXIOS stent. The lesions were accessed via transgastric (n = 7), transesophageal (n = 1), and transduodenal (n = 1) by using a novel access device (NAVIX) in six cases or a 19-G needle in three. Patients were individually followed prospectively for procedure indications, demographic data, previous imaging techniques, technical aspects, clinical outcomes, complications, and follow-up after endoscopic drainage.

Results

The mean size of lesions was 105 ± 26.3 mm (range, 70–150). In six cases, cystoscopy was performed through the stent, including necrosectomy in two. Median procedure time was 25 ± 13 min. A median number of two sessions were performed. The technical success rate was 88.8 % (8/9) due to one failure of the delivery system. One patient developed a tension pneumothorax immediately after transesophageal drainage. No migrations were reported, and all stents were removed easily. All patients had a successful treatment outcome achieving complete cyst resolution. Mean time to stent retrieval was 33 ± 40 days. Mean follow-up was 50 ± 1.3 weeks (range, 45–55), and only one patient presented a recurrence 4 weeks after the stent removal. Furthermore, comparison with ten previous consecutively recruited PFC cases drained by EUS-guided using plastic pigtail stents was done. Technical and clinical successes were similar. However, two stent migrations, two recurrences, and two complications were found. The number of stents used (n = 15) and the median procedure time (42.8 ± 3.1 min) were significantly higher.

Conclusions

Drainage of PFC using dedicated devices as this novel metallic stent with special design seems to be an effective, feasible and safe alternative technique.  相似文献   

15.

Background

Obesity today is a leading cause of global morbidity and mortality, and bariatric surgeries such as laparoscopic sleeve gastrectomy (LSG) are increasingly playing a key role in its management. Such operations, however, carry many difficult and sometimes fatal complications, including leaks. This study aims at evaluating the effectiveness of endoscopic stenting in treating gastric leaks post-LSG.

Methods

A retrospective study was conducted to the patients who were admitted with post-LSG gastric leak at Al-Amiri Hospital Kuwait from October 2008 to December 2012 and were subsequently treated with stenting. The patients were stented endoscopically with self-expandable metal stent (SEMS), and a self-expandable plastic stent (SEPS) was used to facilitate stent removal.

Results

A total of 17 patients with post-LSG leaks underwent endoscopic stenting. The median age was 34 years (range 19–56), 53 % of the patients were male, and mean body mass index (BMI) was 43 kg/m 2 . The median duration of SEMS placement per patient was 42 days (range 28–84). The SEPS-assisted retrieval process took a median duration of 11 days (range 14–35). Successful treatment of gastric leak was evident in 13 (76 %) patients, as evident by gastrografin swallow 1 week after stent removal. In addition, a shorter duration between the LSG and the time of stent placement was associated with a higher success rate of leak seal.

Conclusions

The use of SEMS appears to be a safe and effective method in the treatment of post-LSG leaks, with a success rate of 76 %. The time frame of intervention after surgery is critical, as earlier stent placement is associated with favorable outcomes. Finally, SEPS is often required to facilitate SEMS removal, and further modification of stents and its delivery system may improve results.  相似文献   

16.

Purpose

Current ureteral stents, while effective at maintaining a ureteral lumen, provide a substrate for bacterial growth. This propensity for biofilm formation may be a nidus for bacterial growth leading to infection and a reason for early removal of a stent before it is clinically indicated. A newly devised stent, composed of a highly hydrated, partially hydrolyzed polyacrylonitrile polymer, is believed to have bacterial resistant properties. The objective of this study is to evaluate the biofilm growth and bacterial resistant properties of this novel stent.

Materials and methods

Multiple 1 cm sections of the pAguaMedicina? Pediatric Ureteral Stent (pAMS) (Q Urological, Natick, MA) and the conventional polymer stent (SS) (Boston Scientific, Natick, MA) were incubated for 3 days in the 3 different growth media. Afterward, J96 human pathogenic Escherichia coli was added. At 3, 6, 9, 12, and 15 days following bacterial inoculation, the stent segments were washed, sonicated, and analyzed for bacterial growth. Scanning electron microscopy (SEM) imaging was performed to assess biofilm formation.

Results

pAMS demonstrated significant reductions (43–71 %) in bacterial counts when compared to standard stents in all conditions tested. SEM imaging demonstrated biofilm formation on both types of stents in all media, with a relative reduction in apparent cell debris and bacteria on the pAMS.

Conclusions

In this study, the gel-based stent shows a demonstrable reduction in bacterial counts and biofilm formation. The use of the pAMS may reduce the risk of infection associated with stent usage.  相似文献   

17.

Background

Leaks following oesophageal surgery are considered to be amongst the most dreaded complications and contributory to postoperative mortality. Controversies still exist regarding the best option for the management of oesophageal leaks due to lack of standardized treatment protocols. This study was designed to analyse the feasibility outcome and complications associated with placement of removable, fully covered, self-expanding metallic stents for oesophageal leaks with concomitant minimally invasive drainage when appropriate.

Methods

The study group included 32 patients from a prospectively maintained database of oesophageal leaks, with the majority being anastomotic leaks after minimally invasive oesophagectomy (n = 28), followed by laparoscopic cardiomyotomy (n = 3) and extended total gastrectomy (n = 1). The procedures took place between March 2007 and April 2013.

Results

Most patients had an intrathoracic leak (n = 22), with a mean time to detection of the leak following surgery of 7.50 days (SD = 2.23). Subsequent to endoscopic stenting, enteral feeding via a nasojejunal tube was started on the second day and oral feeding was delayed until the 14th day (n = 31). Six patients underwent thoracoscopic (n = 5) or laparoscopic drainage (n = 1) along with stenting for significant mediastinal and intra-abdominal contamination. The stent migration rate of our study was 8.54 %. The overall success in terms of preventing mortality was 96 %.

Conclusion

Endoscopic stenting should be considered a primary option for managing oesophageal leaks. Delayed oral intake may reduce the incidence of stent migration. Larger stents (bariatric or colorectal stents) serve as a useful option in case of migrated stents. Combined minimally invasive procedures can be safely adapted in appropriate clinical circumstances and may contribute to better outcomes.  相似文献   

18.

Background

Biodegradable (BD) oesophageal stents have been available commercially only since 2008 and previous published research is limited. Our aim was to review the use of BD stents to treat dysphagia in benign or malignant oesophageal strictures.

Methods

Patients were identified from a prospective interventional radiological database. BD stents were inserted radiologically under fluoroscopic control.

Results

Between July 2008 and February 2011, 25 attempts at placing SX-ELLA biodegradable oesophageal stents were made in 17 males and five females, with a median age of 69 (range = 54–80) years. Two patients required more than one BD stent. Indications were benign strictures (n = 7) and oesophageal cancer (n = 17). One attempt was unsuccessful for a technical success rate of 96% with no immediate complications. Clinical success rate was 76%. Median dysphagia score before stent insertion was 3 (range = 2–4) compared to 2 (range = 0–3) after stent insertion (p = 0.0001).

Conclusion

BD stents provide good dysphagia relief for the life time of the stent. They may help avoid the use of feeding tubes in patients having radical chemoradiotherapy or awaiting oesophagectomy. They do not require removal or interfere with radiotherapy planning via imaging. However, the reintervention rate is high after the stent dissolves.  相似文献   

19.

Background

Readmissions to the hospital within 30 days of discharge (30-day readmission rate) may impact stent use in palliative treatment of cancer.

Objective

Our objective was to investigate the incidence of readmission and factors predicting readmissions and long-term outcomes in patients with self-expanding metal stents (SEMS) placed for malignant obstruction.

Methods

Retrospective analysis of all patients who underwent placement of SEMS from 2007 to 2012 for malignant esophageal, gastroduodenal, and colonic obstruction. Incidence and variables associated with 30-day readmission and long-term outcomes were determined.

Results

A total of 191 patients underwent stent placement. The 30-day readmission rate was 17.3 % (N = 33). Readmissions were for stent-related complications in 7.3 % (N = 14) and non-stent-related complications in 9.9 % (N = 19). Stent placement was technically successful in 185 of 191 (96.9 %) and clinically successful in 170 of 191 (89.0 %) patients. On long-term follow-up, 32 (16.8 %) patients needed re-intervention. The mean stent patency was 142 days. Readmission within 30 days was independently associated with development of early complications (<7 days) following stent placement (odds ratio [OR] 5.90; 95 % confidence interval [CI] 2.04–17.1), while the stent location did not impact readmission risk. On Cox regression analysis, American Society of Anesthesiologists physical classification (OR 1.36; 95 % CI 1.02–1.87) and stent location in the esophagus (OR 1.82; 95 % CI 1.10–3.02) were independently associated with long-term mortality.

Conclusions

Early complications following stent placement increase the risk of 30-day readmission. SEMS is efficacious long-term for palliation of malignant gastrointestinal obstruction.  相似文献   

20.

Background

Over the last two decades, self-expanding enteral stents have gained popularity and shown therapeutic potential for strictures, obstructions, fistulae, and perforations of the gastrointestinal (GI) tract. Currently available stent delivery systems make deployment in many locations in the GI tract difficult due to the inability to traverse curves or impossible due to the size requirements of the deployment systems.

Methods

A 67-year-old male presented to our hospital with severe gallstone pancreatitis, requiring a prolonged intensive care unit course. Two days after discharge to a rehabilitation facility he developed acute abdominal pain and pneumoperitoneum. Operative exploration failed to identify a perforation. Subsequently, a left-upper-quadrant abscess developed that was drained percutaneously, yielding coliform bacteria. The drain produced several hundred milliliters of stool a day. A barium enema demonstrated a perforation in the descending colon from an old colo-colic anastomosis site. We proposed a novel over-the-scope (OTS) stent deployment method. Utilizing a heat-activated polymer sheath, the stent was affixed to the endoscope. A modified speed-banding attachment was created to permit release of the polymer sheath once endoscopic and fluoroscopic confirmation of the correct position was obtained.

Results

Utilizing this method of OTS stent deployment, a fully covered 23 × 155 mm self-expanding metal stent (WallFlex, Boston Scientific, Natick, MA) was placed in the colon. Endoscopic and fluoroscopic evaluation following stent placement confirmed stent coverage of the perforation with no ongoing evidence of leak. The patient was discharged to his home state 2 weeks after stent placement in stable condition.

Conclusion

We have developed a novel method of OTS stent placement that permits deployment of a variety of enteral stents on any available endoscope. This method permits placement of fully covered stents in locations in the GI tract not reachable with currently available delivery systems.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号