首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 406 毫秒
1.

Objective:

To compare the diagnostic capabilities between capsule endoscopy (CE) and multislice CT (MSCT) enterography in combination with MSCT angiography for assessment of obscure gastrointestinal bleeding (OGIB).

Methods:

A total of 127 patients with OGIB were looked at in this study. 82 patients (aged 42.7 ± 19.1 years; 34 males) were assigned to receive MSCT diagnosis and 67 patients to (aged 53.9 ± 16.2 years; 28 males) receive CE diagnosis. Among them, 22 patients (aged 54.1 ± 19.1 years; 12 males) received both examinations. Oral isotonic mannitol and intramuscular injection of anisodamine were performed; non-ionic contrast (iopromide, 370 mg I ml−1) was intravenously administered; and then multiphase scanning was conducted at arterial, small intestinal and portal venous phases in MSCT. The results were compared with findings of reference standards including double balloon enteroscopy, digital subtraction angiography, intraoperative pathological examination and/or clinical diagnosis.

Results:

Administration of anisodamine markedly increased the satisfaction rate of bowel filling (94.67% vs 28.57%; p < 0.001) but not the diagnostic yield (p = 0.293) of MSCT. Compared with MSCT, CE showed an improved overall diagnostic yield (68.66% vs 47.56%; p = 0.010), which was also observed in overt bleeding patients (i.e. patients with continued passage of visible blood) (76.19% vs 51.02%; p = 0.013) and in patients aged younger than 40 years of age (85% vs 51.28%; p = 0.024). However, CE had similar positive rates to MSCT (p > 0.05). Among the 22 cases in whom both examinations were conducted, CE showed no significantly different diagnostic capability compared with MSCT (p = 0.4597).

Conclusion:

Both CE and MSCT are safe and effective diagnostic methods for OGIB.

Advances in knowledge:

CE is preferred for overt bleeding or patients aged younger than 40 years. The combined use of CE and MSCT is recommended in OGIB diagnosis.Obscure gastrointestinal bleeding (OGIB), which accounts for approximately 5% of all gastrointestinal haemorrhage cases,1 is defined as persistent or recurring gastrointestinal bleeding without an obvious aetiology after gastroduodenoscopy and colonoscopy.2,3 Based on the presence or absence of clinically evident bleeding, OGIB could be divided into occult (no visible blood) and overt (continued passage of visible blood, such as haematemesis, melaena or haematochezia) bleeding.3,4 OGIB frequently occurs in the small bowel and is caused by small bowel diseases such as intestinal erosions, ulcers, vascular anomaly, gastrointestinal tumours and inflammatory bowel and parasitic diseases.5,6Multiple diagnostic techniques have been developed to elucidate the causes of OGIB. Among them, two non-invasive technologies, capsule endoscopy (CE) and multislice CT (MSCT) markedly improved the ability to determine the causes of OGIB by allowing the visualization of the gastrointestinal tract.2,3,6 CE is able to obtain direct visualization of mucosal surface of the entire small intestine.4,7,8 However, capsule retention remains a major risk of CE diagnosis.4,911 In addition, the visual field restriction limits the value of CE in diagnosis of umbilicate or extraluminal lesions, since the small bowel is difficult to evaluate owing to its large length and tortuous course.4,10 Conversely, MSCT, including MSCT angiography (MSCTA), MSCT enteroclysis and MSCT enterography (MSCTE), has full capacity to depict the extraintestinal lesions, owing to the combination of the advantages of enteral volume challenge with the ability of cross-sectional imaging.4,12 Yet, substantial patient radiation exposure is one of the major disadvantages of MSCT diagnosis.3,13 Careful preparation is also needed before examination.14 Considering that both CE and MSCT have advantages and disadvantages, a limited number of published data have compared the two diagnostic tools in patients with OGIB.4,6,1517 However, most of these studies did not refer to MSCTA, and apparently different results were obtained owing to the advancement of the two technologies. Thus, an updated and comprehensive comparison is required.Hence, we compared the diagnostic capability of MSCTE in combination with MSCTA with CE in patients suffering from OGIB. In this study, MSCTE and MSCTA technologies performed with a 64-slice spiral CT scanner were combined by non-contrast-enhanced scanning after oral administration of a neutral enteric contrast material (isotonic mannitol, 2.5%) and the intramuscular injection of anisodamine to restrain enterocinesia, and the following multiphase scanning at arterial, small intestinal and portal venous phases followed the intravenous infusion of non-ionic iodinated contrast material (iopromide, 370 mg I ml−1). In addition, the influences of the clinical bleeding pattern and age on the diagnostic capability were also investigated.  相似文献   

2.

Objective:

Analysis of “cine” MRI using segmental regions of interest (ROIs) has become increasingly popular for investigating bowel motility; however, variation in motility in healthy subjects both within and between scans remains poorly described.

Methods:

20 healthy individuals (mean age, 28 years; 14, males) underwent MR enterography to acquire dynamic motility scans in both breath hold (BH) and free breathing (FB) on 2 occasions. Motility data were quantitatively assessed by placing four ROIs per subject in different small bowel segments and applying two measures: (1) contractions per minute (CPM) and (2) Jacobian standard deviation (SD) motility score. Within-scan (between segment) variation was assessed using intraclass correlation (ICC), and repeatability was assessed using Bland–Altman limits of agreement (BA LoA).

Results:

Within-scan segmental variation: BH CPM and Jacobian SD metrics between the four segments demonstrated ICC R = 0.06, p = 0.100 and R = 0.20, p = 0.027 and in FB, the CPM and Jacobian SD metrics demonstrated ICC R = −0.26, p = 0.050 and R = 0.19, p = 0.030. Repeatability: BH CPM for matched segments ranged between 0 and 14 contractions with BA LoA of ±8.36 and Jacobian SD ranged between 0.09 and 0.51 with LoA of ±0.33. In FB data, CPM ranged between 0 and 10 contractions with BA LoA of ±7.25 and Jacobian SD ranged between 0.16 and 0.63 with LoA = ±0.28.

Conclusion:

The MRI-quantified small bowel motility in normal subjects demonstrates wide intersegmental variation and relatively poor repeatability over time.

Advances in knowledge:

This article presents baseline values for healthy individuals of within- and between-scan motility that are essential for understanding how this process changes in disease.Dynamic “cine” MRI acquired during MR enterography is increasingly utilized to assess bowel motility in a range of conditions, notably inflammatory bowel disease and enteric dysmotility syndromes.14 Analysis of the data remains primarily subjective in clinical routine, but the ability to apply quantitative techniques makes this a potentially powerful methodology to explore gastrointestinal physiology in disease as well as an emerging application as a biomarker for drug efficacy.57Despite the growing literature, a consensus has yet to be reached as to the best method of quantitatively analysing small bowel data and indeed a range of motility metrics are proposed.2,3,812 The most commonly used metric is the change in luminal diameter at a fixed anatomical position through the time series. By tracking bowel diameter, a characteristic curve can be produced with the number of contractions expressed per minute (CPM) to give an intuitive and broadly accepted metric for small bowel motility (SBM).24,9,11,1315 To date, several studies have reported a relationship between CPM and dysmotility in disease, either compared with a histopathological standard or “normal” reference bowel loops.24,12 An array of additional metrics derived both from bowel diameter measures and more abstract processing techniques have further been implemented with varying degrees of effectiveness in disease and health.2,4,5,8,10,14,16Although intuitively attractive, the robustness of assessing overall enteric motility using only an isolated loop of bowel has received relatively little attention to date irrespective of the precise metric applied. It is unclear how representative the selected bowel loops are of overall SBM and if normal motility intrinsically differs between bowel segments, for example, between the jejunum and ileum. Furthermore, the repeatability of single loop metrics, even in normal individuals, is not well described, knowledge of which is vital if segmental analysis is to be used to diagnose, guide treatment and monitor enteric pathology.The purpose of this study is to explore segmental variation in SBM in healthy volunteers measured using two commonly reported small bowel metrics [CPM and Jacobian standard deviation (SD)] looking at (1) within-scan motility variation between different segments and (2) between-scan variation (repeatability) across two time points.  相似文献   

3.

Objective:

To investigate the specificity of the neck shaft angle (NSA) to predict hip fracture in males.

Methods:

We consecutively studied 228 males without fracture and 38 with hip fracture. A further 49 males with spine fracture were studied to evaluate the specificity of NSA for hip-fracture prediction. Femoral neck (FN) bone mineral density (FN-BMD), NSA, hip axis length and FN diameter (FND) were measured in each subject by dual X-ray absorptiometry. Between-mean differences in the studied variables were tested by the unpaired t-test. The ability of NSA to predict hip fracture was tested by logistic regression.

Results:

Compared with controls, FN-BMD (p < 0.01) was significantly lower in both groups of males with fractures, whereas FND (p < 0.01) and NSA (p = 0.05) were higher only in the hip-fracture group. A significant inverse correlation (p < 0.01) was found between NSA and FN-BMD. By age-, height- and weight-corrected logistic regression, none of the tested geometric parameters, separately considered from FN-BMD, entered the best model to predict spine fracture, whereas NSA (p < 0.03) predicted hip fracture together with age (p < 0.001). When forced into the regression, FN-BMD (p < 0.001) became the only fracture predictor to enter the best model to predict both fracture types.

Conclusion:

NSA is associated with hip-fracture risk in males but is not independent of FN-BMD.

Advances in knowledge:

The lack of ability of NSA to predict hip fracture in males independent of FN-BMD should depend on its inverse correlation with FN-BMD by capturing, as the strongest fracture predictor, some of the effects of NSA on the hip fracture. Conversely, NSA in females does not correlate with FN-BMD but independently predicts hip fractures.Hip fracture is the worst osteoporotic fracture with regard to cost1,2 and adverse consequences,3,4 so its prevention by checking for the related fracture risk factors is an important goal. Although low bone mineral density (BMD) is generally recognized as the main risk factor for hip fracture,5,6 there is growing evidence that other bone characteristics, such as proximal femur geometry (PFG) parameters, are implicated in determining the risk profile for hip fracture.7,8 This evidence, however, mainly derives from studies carried out in females,913 whereas contradictory results characterize studies carried out in males.1420 Authors'' opinions seem to vary widely about the ability of the neck shaft angle (NSA), one of the PFG factors, to predict osteoporotic hip fractures in males,1416,21 whereas its association with the risk of hip fracture in females10,11,14,22 is generally accepted. Gender differences in the hip anatomy23 have been put forward as a possible explanation for the different relationship of NSA with the hip-fracture risk between genders, whereas geographic and racial differences24 among the examined male populations have been advocated as a possible cause of authors'' discrepancies on the relationship between NSA and the hip-fracture risk in males.This topic is therefore still under debate, and further studies are required to clarify the association of the NSA with hip-fracture risk in males. The authors of the current study contribute to this topic by studying the relationship between NSA and the hip fragility fracture in a sample of white Italian males.  相似文献   

4.
5.

Objective:

To compare Dixon-based MRI techniques for intramuscular fat quantification at 3 T with MR spectroscopy (MRS) in vitro and in vivo.

Methods:

In vitro, two- three- and four-point mDixon (Philips Medical Systems, Best, Netherlands) sequences with 10°, 20° and 30° flip angles were acquired from seven test phantoms with sunflower oil–water percentages of 0–60% sunflower oil and calculated fat–water ratios compared with MRS. In vivo, two- three- and four-point mDixon sequences with 10° flip angle were acquired and compared with MRS in the vastus medialis of nine healthy volunteers (aged 30.6 ± 5.3 years; body mass index 22.2 ± 2.6).

Results:

In vitro, all mDixon sequences correlated significantly with MRS (r > 0.97, p < 0.002). The measured phantom percentage fat depended significantly on the flip angle (p ≤ 0.001) and mDixon sequence (p = 0.005). Flip angle was the dominant factor influencing agreement with MRS. Increasing the flip angle significantly increased the overestimation of the mDixon sequences compared with MRS. In vivo, a significant difference was observed between sequences (p < 0.001), with all mDixon sequences overestimating the intramuscular fat content of the vastus medialis muscle compared with MRS. Two-point mDixon agreed best with MRS and had comparable variability with the other mDixon sequences.

Conclusion:

This study demonstrates that mDixon techniques have good linearity and low variability for use in intramuscular fat quantification. To avoid significant fat overestimation with short repetition time, a low flip angle should be used to reduce T1 effects.

Advances in knowledge:

This is the first study investigating the optimal mDixon parameters for intramuscular fat quantification compared with MRS in vivo and in vitro.Chronic diseases associated with obesity are strongly related to the amount of adipose tissue in and around skeletal muscle tissue.1,2 Furthermore, many pathology exists, including cerebral palsy, where the patients exhibit reduced fat-free mass3,4 but have increased fat infiltration into skeletal muscle.5 Therefore, an effective method for quantification of intramuscular fat is required to determine which patients may develop obesity-related chronic diseases.In the literature,69 fat–water fraction measurements are predominantly obtained using localized proton (1-H) MR spectroscopy (MRS). However, MRS has a limited spatial resolution compared with imaging techniques. Consequently, MRI techniques for the measurement of fat–water ratios are desirable, particularly in spatially heterogeneous tissue. Chemical shift imaging methods established on the Dixon technique10 that discriminate between fat and water spins based on their different resonance frequencies are now available on the majority of clinical MRI systems and are increasingly applied in clinical settings (mDixon, Philips Medical Systems, Best, Netherlands; Dixon, Siemens Healthcare, Erlangen, Germany; FatSep, Hitachi, Tokyo, Japan; and IDEAL, GE Healthcare, Waukesha, MI).The original two-point Dixon (2PD) technique10 acquired two images using a modified spin-echo pulse sequence. One image is a conventional spin-echo image with water and fat in phase, the second is acquired with the read out gradient shifted to produce an image with 180° water–fat phase difference. These images then undergo complex addition or subtraction to produce water only and fat only images, respectively, from which a fat–water ratio image can be calculated. Therefore, a fat–water fraction measurement can be made for a much larger region of interest and with much higher spatial resolution using Dixon techniques than MRS. The three-point Dixon (3PD) technique11 was developed to reduce sensitivity to magnetic field inhomogeneities and, therefore, phase errors associated with 2PD12 by utilizing a combination of multipoint acquisition and image processing techniques. A four-point Dixon (4PD) technique has also been developed,13 in which the extra acquisition enables a more accurate correction of the phase error. Recent advancements in image processing techniques, such as iterative decomposition of water and fat with echo asymmetry and least-squares approach (IDEAL)14,15 have further helped to separate fat and water signals in inhomogeneous magnetic field regions.Dixon imaging techniques have been widely used in the literature1623 for hepatic fat quantification hepatic steatosis (for a review see Reeder and Sirlin16) and are increasingly utilized for intramuscular fat quantification. However, limited validation studies comparing Dixon and MRS techniques for intramuscular fat quantification have been reported.24 The purpose of this study was to perform such a validation at 3.0 T, as well as investigating optimal strategies by comparing two-, three- and four-point mDixon each with a range of flip angles.  相似文献   

6.

Objective:

To study the accuracy of CT for staging T3a (TNM 2009) renal cell carcinoma (RCC).

Methods:

Unenhanced and nephrographic phase CT studies of 117 patients (male:female = 82:35; age range, 21–86 years) with T1–T3a RCC were independently reviewed by 2 readers. The presence of sinus or perinephric fat, or renal vein invasion and tumour characteristics were noted.

Results:

Median (range) tumour size was 5.5 (0.9–19.0) cm; and 46 (39%), 16 (14%) and 55 (47%) tumours were pT1, pT2 and pT3a RCC, respectively. The sensitivity/specificity for sinus fat, perinephric fat and renal vein invasion were 71/79%, 83/76% and 59/93% (Reader 1) and 88/71%, 68/72% and 69/91% (Reader 2) with κ = 0.41, 0.43 and 0.61, respectively. Sinus fat invasion was seen in 47/55 (85%) cases with T3a RCC vs 16/55 (29%) and 33/55 (60%) for perinephric fat and renal vein invasion. Tumour necrosis, irregularity of tumour edge and direct tumour contact with perirenal fascia or sinus fat increased the odds of local invasion [odds ratio (OR), 2.5–3.7; p < 0.05; κ = 0.42–0.61]. Stage T3a tumours were centrally located (OR, 3.9; p = 0.0009).

Conclusion:

Stage T3a RCC was identified with a sensitivity of 59–88% and specificity of 71–93% (κ = 0.41–0.61). Sinus fat invasion was the most common invasive feature.

Advances in knowledge:

Centrally situated renal tumours with an irregular tumour edge, inseparable from sinus structures or the perirenal fascia and CT features of tumour necrosis should alert the reader to the possibility of Stage T3a RCC (OR, 2.5–3.9).Current guidelines1 recommend nephron-sparing procedures (either partial nephrectomy or ablation) for Stage T1a (<4 cm) renal cell carcinomas (RCCs), but the indications for nephron-sparing procedures are widening.2 Successful surgical series have been reported with Stage T1b (<4–7 cm) tumours and even Stage T2 RCCs.3 Central location is not necessarily a barrier to good clinical outcome after partial nephrectomy,3 but nephron-sparing procedures are contraindicated for stage ≥T3a renal cancers.1 Thus, prior accurate recognition of T3a stage is important, especially with central renal masses, as any pre-operative suspicion of local invasion should contraindicate nephron-sparing surgery or ablation.In the most recent TNM iteration, Stage T1 and T2 tumours are defined by tumour diameter (T1a, ≤4 cm; T1b, 4–7 cm; T2a, 7–10 cm; and T2b, ≥10 cm) and the absence of any local invasion. Stage T3a RCC was redefined to include invasion of either renal sinus or perinephric fat.4 Renal vein invasion [main renal vein and/or segmental (muscle-containing) branch invasion], without caval involvement, was downgraded from Stage T3b to Stage T3a, whilst adrenal invasion was upgraded from Stage T3a to Stage T4. Size is not a governing factor with ≥T3a tumours, and some renal masses <7 cm in diameter will be locally advanced. Nearly half of all pT3a RCCs (n = 309/623) in one study were <7 cm in diameter.5 Other studies have confirmed the poor prognostic significance of sinus fat or venous invasion in masses <7 cm, with a 4–6 times increased risk of cancer-related death.6,7 Centrally located masses are more likely to demonstrate local invasion with positive surgical resection margins after partial nephrectomy,8,9 and unrecognized sinus invasion may explain the recurrence of cancer, and subsequent death from metastatic disease, in some cases of presumed T1 RCCs.8However, in previous studies, CT staging has been variably accurate1018 for RCCs, and staging inaccuracies, usually understaging, are said to be most common with Stage T3a disease.12,17 For venous invasion, the specificity and sensitivity have ranged between 58–97% and 32–96%,10,1416 and for perinephric infiltration, the figures have been 32–96% and 85–93%,1416 respectively. The CT accuracy for sinus fat invasion has not been previously investigated. The primary aim of this study was to define the accuracy of contrast-enhanced CT for identifying any of the three defining features of Stage T3a RCC, that is, sinus or perinephric fat invasion, or renal vein invasion. Secondary study objectives were to identify any tumour characteristics that increase the odds of T3a disease and may be used as accessory CT signs to alert the reader to an increased likelihood of local invasion by RCC.  相似文献   

7.
8.

Objective:

To review the knowledge of radiographers and examine the possible sociodemographic and situational contributors to this knowledge.

Methods:

A questionnaire survey was devised and distributed to a cohort of 120 radiographers. Each questionnaire contained two sections. In the first section, background data, including sex, age, highest academic level, grade point average (GPA), length of time from graduation, work experience as a radiographer and the status of previous refresher course(s), were collected. The second section contained 17 multiple-choice questions concerning radiographic imaging parameters and safety issues.

Results:

The response rate was 63.8%. In univariate analytic model, higher academic degree (p < 0.001), higher GPA (r2 = 0.11; p = 0.001), academic workplace (p = 0.04) and taking previous refresher course(s) (p = 0.01) were significantly associated with higher knowledge score. In multivariate analytic model, however, higher academic degree (B = 1.62; p = 0.01), higher GPA (B = 0.50; p = 0.01) and taking previous refresher course(s) (B = −1.26; p = 0.03) were independently associated with higher level of knowledge. Age, sex, length of time from graduation and work experience were not associated with the respondents'' knowledge score.

Conclusion:

Academic background is a robust indicator of a radiographer''s professional knowledge. Refresher courses and regular knowledge assessments are highly recommended.

Advances in knowledge:

This is the first study in the literature that examines professional knowledge of radiographers in terms of technical and safety issues in plain radiography. Academic degree, GPA and refresher courses are independent predictors of this knowledge. Regular radiographer professional knowledge checks may be recommended.The Joint Commission on Accreditation of Healthcare Organizations mandates “processes that are designed to ensure that the competency of all staff members is assessed, maintained, demonstrated and improved on an ongoing basis.” Tests with practical questions that reflect the knowledge required to perform daily examinations have been proposed as effective tools to attain this purpose. The results enable us to take on existing blemishes and improve the competency.1Medical imaging, as a field with growing complexity and increasing impact on diagnosis, plans of management and patient health status,2 is a good example of raised requirements for competency.38Knowledge assessment may be useful for detecting possible weaknesses in an organization and spotlighting existing educational flaws and shortcomings.9 According to some reports, knowledge assessment takes priority over checking competency,7,10 particularly in professions that are completely mediated by technology.11In addition, although clinical education is the mainstay for developing skills, it has been shown that the combination of practical and theoretical education would lead to a significantly better outcome in the field of teaching. This integrated approach of using both knowledge and practice in education enables the trainee to work more competently and be prepared to take responsibility in his/her future career.12Although radiography using film for imaging the internal organs of the body has been introduced for over a century,13 it is still among the most widespread and useful imaging modalities all over the world. Radiographers are generally in charge of radiological equipment, imaging examination and frequently nursing care.7,14,15Incompetent radiographers could render radiographic examinations suboptimal. A poor radiographic technique, in turn, may lead to unnecessary exposures to X-radiation, poor image quality, repeated views and examinations, patient discomfort or further injury because of poor positioning and the possibility of a missed diagnosis or misdiagnosis.16Furthermore, a rapid shift from conventional to fully digitized radiology departments, along with rapidly evolving changes in healthcare administration17 entails knowledgeable, up-to-date radiographers who utilize the technology.18Except for very limited number of studies that have described radiographers'' self-reported competency7,16 and the level of awareness pertaining to the protection against radiation,19,20 to the best of our knowledge, there is no study in the literature regarding radiographers'' level of knowledge with a dedicated focus on technical parameters and safety in plain radiography.This study sets out to examine knowledge amongst a cohort of radiographers and to investigate possible association of some sociodemographic and situational factors with the level of this knowledge.  相似文献   

9.

Objective:

To evaluate the usefulness of diffusion-weighted MRI (DWI) for the assessment of the intraindividual follow-up in patients with chronic periaortitis (CP) under medication.

Methods:

MRI data of 21 consecutive patients with newly diagnosed untreated disease were retrospectively examined before and after medical therapy, with a median follow-up of 16 weeks. DWI parameters [b800 signal, apparent diffusion coefficient (ADC) values] of the CP and psoas muscle were analysed together with the extent and contrast enhancement. Pre- and post-treatment laboratory inflammation markers were acquired parallel to each MR examination.

Results:

Statistically significant lower b800 signal intensities (p ≤ 0.0001) and higher ADC values (p ≤ 0.0001) were observed after medical treatment within the fibrous periaortic tissue. Extent and contrast enhancement of the CP showed also a statistically significant decrease (p ≤ 0.0001) in the follow-up examinations, while the control parameters within the psoas muscle showed no differences.

Conclusion:

DWI seems to be a useful method for the evaluation of response to treatment without contrast agents. The technique may be helpful in the assessment of disease activity to guide further therapeutic strategies.

Advances in knowledge:

DWI detects significant differences in the intraindividual follow-up of CP under medical therapy.Chronic periaortitis (CP) is a proliferating fibroinflammatory disease of the perivascular retroperitoneal space and aortic wall.14 Owing to adventitial inflammation, some recent theories consider CP as a large vessel vasculitis.5 Clinical manifestations of CP include idiopathic retroperitoneal fibrosis, inflammatory aortic aneurysm and perianeurysmal retroperitoneal fibrosis.2,6,7 The three manifestations with very similar histopathological characteristics are distinguished by the diameter of the abdominal aorta and concomitant ureteral affection.1,3,7Specific clinical symptoms are caused by extrinsic compression of the ureters or retroperitoneal veins, resulting in hydronephrosis, oliguria, lower extremity oedema and deep vein thrombosis.1,8Under medical treatment with steroids, CP has a good prognosis.7 Today tamoxifen is suggested as a safe and effective therapeutic alternative, and immunosuppressive drugs can be considered in patients with suboptimal responses to these drugs or multiple relapses.911CT and MRI are the modalities of first choice for diagnosis and follow-up of CP.1,7,12 The fibrotic para-aortic tissue shows significant contrast uptake in gadolinium-enhanced MRI.1214 Dynamic contrast-enhanced MRI was suggested for the assessment of the disease activity.15,16 However, in cases with impaired renal function (e.g. by ureteral compression), gadolinium-independent imaging methods should be preferred owing to the potential development of a nephrogenic systemic fibrosis.17Diffusion-weighted MRI (DWI) is a non-contrast MR modality that has been successfully applied for the assessment of retroperitoneal masses, inflammatory abdominal aortic aneurysms and for the differentiation between retroperitoneal fibrosis and malignant retroperitoneal neoplasms.1821DWI indicates restricted diffusion of water, for example caused by a high cellularity in malignant disease or active inflammation. The apparent diffusion coefficient (ADC) is a quantitative parameter for the level of restricted diffusion, which is calculated from the signals of different diffusion gradients (b-values).22In the context of untreated CP diffusion-weighted MRI may detect restricted inflammation as a sign of high cellularity caused by active inflammation.There are no data for the evaluation of intraindividual follow-up and the response to treatment by DWI of CP so far. Therefore, the aim of the present study was to analyse differences in DWI signals during follow-up in patients with CP before and after treatment. In addition, we sought to elucidate the potential of DWI in the therapy monitoring of CP.  相似文献   

10.

Objective:

To determine prevalence, clinicoradiological characteristics and outcome of patients with mesenteric panniculitis (MP) in a large hospital-based population.

Methods:

Consecutive abdominal CT examinations of 3820 patients were evaluated for MP. Clinical characteristics, therapy and outcome of patients with MP were evaluated during a 5-year follow-up period. A matched pair analysis was performed to further investigate the relation between MP and malignancy.

Results:

94 (2.5%) patients with MP were identified (mean age, 66.6 ± 11.2 years, 70.2% male). MP coexisted with malignancy (especially prostatic carcinoma) in 48.9% of patients, and this was slightly but significantly higher than in age- and sex-matched control patients (n = 188, 46.3%). In 48 patients, MP was presumed to be idiopathic. The most frequent presenting symptom was pain (54.3%). Laboratory findings revealed increased acute-phase reactants in half of the patients with MP. CT findings included increased density of mesenterial fat (mean, −56.8 ± 10.8 HU), fat ring sign, tumoural pseudocapsule and small soft-tissue nodules. Patients with MP (14.6%) developed significantly more malignancies during a 5-year follow-up than did the control group (6.9%). One patient was treated with prednisone without satisfactory response.

Conclusion:

The prevalence of MP in this study was 2.5%. In most patients, radiologic features included increased mesenteric fat density, fat ring sign and small soft-tissue nodules. MP was associated with a significant higher prevalence of coexisting malignancies and a higher prevalence of future cancer development.

Advances in knowledge:

A more accurate prevalence of MP on CT is demonstrated. An underlying malignancy may play a role.Mesenteric panniculitis (MP) is a rare, idiopathic disorder characterized by chronic inflammation of the mesenteric fat. Numerous terms have been reported in literature depending on the pre-dominant presentation, including mesenteric lipodystrophy, sclerosing mesenteritis, mesenteric Weber–Christian disease and retractile mesenteritis or mesenteric fibrosis.18 It is now considered that these different diagnostics entities represent a spectrum of a single disease characterized by non-specific inflammation of the mesentery fat that may ultimately lead to fibrosis and retraction.1,9,10 The aetiology of MP remains unknown; it may occur independently or in association with other disorders. Various causes have been suggested, including autoimmune disorders, infection, trauma (including recent surgery) and ischaemia of the mesentery.11,12 It has a poorly understood association with underlying malignancy with conflicting results in literature, which suggests that it may be a paraneoplastic condition at least in some patients.1316Owing to the increased use of abdominal diagnostic imaging and the identification of specific signs on CT, MP is being recognized with increasing frequency at CT imaging. To date, mainly case reports and a few larger studies on MP have been published with conflicting results. Reported prevalence rates range from 0.16% to 7.80%.1317 Most studies reported this condition in patients in middle and late adulthood with a slight male predominance. Patients may be entirely asymptomatic or present with non-specific mainly gastrointestinal manifestations, including abdominal pain, constipation or diarrhoea, an asymptomatic abdominal mass, weight loss, fever or chylous ascites.1821 Depending on the underlying disease, the natural course of MP is often benign and self-limiting, although few data are available on the clinical outcome and response to therapy of patients with MP.The aim of this study was to gain more insight into the prevalence and natural course of MP using strict criteria. We assessed prevalence, clinicoradiological characteristics and outcome of MP during a 5-year follow-up period in a large hospital-based population with specific focus on the relation between MP and malignancy.  相似文献   

11.

Objective:

This study investigates the factors associated with higher doses for both single-plane and biplane procedures and establishes centre-specific 75th percentile levels.

Methods:

602 patients undergoing coronary angiography in a large hospital at Sydney were recruited to the study, and causal agents for high radiation doses were investigated: gender, procedural complexity, severity of coronary artery disease, presence of coronary bypass grafts, entry approach (radial or femoral), level of operator experience; and a single-plane or a biplane imaging system was employed.

Results:

The 75th percentile levels were calculated. The results demonstrated that, for both systems, higher exposures were associated with patients who were male (p<0.001), had coronary vessel disease (p<0.001) and had a history of coronary bypass grafts (p<0.001). In addition, for biplane systems, procedural complexity (p<0.001), types of entry approach (p<0.001) and levels of operator experience (p<0.001) significantly impacted upon the dose. Biplane examinations recorded higher doses than single-plane procedures (p<0.001) and the inclusion of left-sided ventriculography contributed to the overall dose by up to 10%.

Conclusion:

The 75th percentile levels in this study represent the tentative reference levels and are 48.9, 44.2 and 56 Gy cm2 for all exposures, single-plane- and biplane-specific exposures, respectively, and compare favourably with the diagnostic reference level values established elsewhere internationally, with only the UK and Irish data being lower.

Advances in knowledge:

Specific agents have been identified for dose-reducing strategies and the importance of operator training is highlighted. The assumption that biplane procedures may reduce the patient dose should be treated with caution.Diagnostic coronary angiography is regarded as an essential imaging and therapeutic tool, given the high incidence of cardiovascular disease in Australia, with 18% of Australians having chronic cardiovascular disease [1,2]. It is the most common invasive cardiac procedure and is used for both the initial diagnosis of coronary artery disease (CAD) and the follow-up examinations of patients after coronary interventional procedures, coronary bypass surgery or cardiac transplantation [3,4]. It is a standardised procedure that involves several cine-fluorographic series of the right and left coronary artery systems, with or without a left ventriculogram [5].Recently, the rapid increase in the frequency of diagnostic coronary angiography procedures has prompted radiation protection concerns [6], and studies have been performed to determine patient radiation doses in a number of countries [1,3,5,7]. The radiation dose of diagnostic coronary angiography is often presented in the form of a diagnostic reference level (DRL) [8], which is established at the 75th percentile dose–area product (DAP) value of the distributions of doses observed for a particular examination [9]. The main purpose of DRLs is to facilitate the optimisation of the radiation dose for a particular type of examination by identifying practices with unnecessarily high patient doses [8] and serving as a benchmark for the comparison of radiation dose among countries [10].Diagnostic coronary angiography can be performed using single-plane and biplane imaging systems. Biplane diagnostic coronary angiography enables two cine-angiography runs to be recorded simultaneously from two orthogonal planes during a single injection of contrast medium [11]. Single-plane diagnostic coronary angiography views the individual in one plane (with one X-ray tube) and acquires patient depth information by altering the tube position between X-ray exposures [11].In terms of clinical usage, biplane diagnostic coronary angiography has been reported to be more efficient than single-plane diagnostic coronary angiography [11]. Biplane imaging should be faster, employ reduced fluoroscopy time, require fewer cine-angiography runs and therefore involve lower average radiation dose to the patient than that of single-plane imaging, prompting recommendations for its use in paediatric examinations [11]. Despite these advantages, other researchers have suggested that biplane diagnostic coronary angiography is complicated and requires longer set-ups that can result in increased radiation exposure to both the operator and the patients [7,1214].The aim of this study is to address the current biplane imaging debate by examining radiation doses in a large metropolitan teaching hospital in Sydney, NSW, Australia. It will also explore the impact that a number of patients and procedural factors have on dose, such as gender, procedural complexity, severity of CAD, presence of coronary artery bypass grafts, types of entry approach and levels of operator experience. The baseline radiation dose for diagnostic coronary angiography will be provided and compared with published DRLs.  相似文献   

12.

Objective:

Depression is common in patients with Alzheimer''s disease (AD) and mild cognitive impairment (MCI). Patients with depression have an earlier onset and rapid progression of cognitive decline. Medial temporal lobe atrophy (MTA) is common in AD and MCI, and some degree of atrophy is found in almost all patients. In the present study, an attempt was made to know if MTA is more common in patients with AD/MCI with depression than those without it.

Methods:

Patients reporting to the outpatient department of a neurology centre of a tertiary care hospital were recruited for the present study. After initial general physical and neurological examination, they were evaluated using National Institute of Neurological and Communicative Disorders and Stroke and Related Disorders Association criteria for diagnosis of AD. Clinical Dementia rating scale was used for the diagnosis of MCI. Cornell scale for depression in dementia (CSDD) was used.

Results:

We found 20 cases with depression as per CSDD out of a sample of 37 patients (male:female = 30:7). There were 26 patients with AD and 11 with MCI. The mean age of all patients was 72.33 ± 6.45 years. The mean mini mental status examination score was 19.00 ± 6.73. The mean time since diagnosis was 4.19 ± 3.26 years. The mean Scheltens visual rating scale score for right MTA was 2.08 ± 0.95 and was 2.05 ± 0.94 for the left. Both scores did not differ statistically when analyzed using paired t-test (p > 0.05). However, difference in those with depression (2.36 ± 0.95) from those without depression (1.60 ± 0.74) was significant (p < 0.05).

Conclusion:

MTA scores were higher in those with AD/MCI with depression than those without it.Depression1 is common in patients with Alzheimer''s disease (AD) and mild cognitive impairment (MCI). Relationship between depression and cognitive decline is a complex one, and depression is both an aetiological risk factor2 and comorbidity for dementia.3 Incidence and prevalence of depressive symptoms in MCI range from 15% in population-based studies to 44% in hospital-based studies.4 Likewise, up to two-thirds of patients with AD have been reported to have depression.5 Because in many studies, depression has been seen to be an early manifestation of AD, it has been suggested that it may represent a continuum4 from depression to MCI to AD (late-life depression → MCI → AD). Two recent meta-analyses have found that a history of depression approximately doubles an individual''s risk for subsequent dementia in general and AD in particular.6 Depression is known to be neurotoxic to medial temporal lobe structures and can contribute to their atrophy.79 Atrophy is more so, when depression is severe or recurrent7 and medial temporal lobe atrophy (MTA) has a temporal association with depression.9 Continued treatment of depression has been shown to protect the hippocampus from the ill effects of depression.10 Although volumetric method could be a preferred mode of measuring the hippocampal volume in AD, qualitative rating of MTA is a good alternative.11 Visual rating of the hippocampal volume1214 can be carried out using Scheltens et al15 rating scale that is based on the width of the choroid fissure, the width of the temporal horn and the height of hippocampal formation and is a quantitative scale.  相似文献   

13.

Objective:

To consider the implications of the use of biphasic rather than monophasic repair in calculations of biologically-equivalent doses for pulsed-dose-rate brachytherapy of cervix carcinoma.

Methods:

Calculations are presented of pulsed-dose-rate (PDR) doses equivalent to former low-dose-rate (LDR) doses, using biphasic vs monophasic repair kinetics, both for cervical carcinoma and for the organ at risk (OAR), namely the rectum. The linear-quadratic modelling calculations included effects due to varying the dose per PDR cycle, the dose reduction factor for the OAR compared with Point A, the repair kinetics and the source strength.

Results:

When using the recommended 1 Gy per hourly PDR cycle, different LDR-equivalent PDR rectal doses were calculated depending on the choice of monophasic or biphasic repair kinetics pertaining to the rodent central nervous and skin systems. These differences virtually disappeared when the dose per hourly cycle was increased to 1.7 Gy. This made the LDR-equivalent PDR doses more robust and independent of the choice of repair kinetics and α/β ratios as a consequence of the described concept of extended equivalence.

Conclusion:

The use of biphasic and monophasic repair kinetics for optimised modelling of the effects on the OAR in PDR brachytherapy suggests that an optimised PDR protocol with the dose per hourly cycle nearest to 1.7 Gy could be used. Hence, the durations of the new PDR treatments would be similar to those of the former LDR treatments and not longer as currently prescribed.

Advances in knowledge:

Modelling calculations indicate that equivalent PDR protocols can be developed which are less dependent on the different α/β ratios and monophasic/biphasic kinetics usually attributed to normal and tumour tissues for treatment of cervical carcinoma.The use of low-dose-rate (LDR) brachytherapy (BT) for cervical cancer is being phased out and replaced by either high-dose-rate (HDR) or pulsed-dose-rate (PDR) BT [14]. At the Christie Hospital in Manchester, UK, PDR has been implemented in place of LDR for the BT component of a combined external beam (EB) and BT treatment of cervical carcinoma [4]. The Groupe Europeen de Curietherapie–European Society for Radiotherapy & Oncology (GEC-ESTRO) recommendations [5] were used to calculate the equivalent prescribed doses of PDR BT compared with those of the formerly used LDR-BT protocol [6]. Those guidelines use generic values of linear-quadratic parameters and monophasic repair kinetics. For the organs at risk (OARs), biphasic repair has become a more accurate characterisation of the repair kinetics. This is based on clinical evidence of a slow repair component for skin telangiectasia [7], oral mucosa [8] and subcutaneous fibrosis [9]. There is also more detailed knowledge of the two fast and slow components for clonogenic cells in mouse kidney [10], rat spinal cord paralysis [11], mouse pneumonitis [12,13] and pig skin early reactions [14].PDR BT uses cycles (or pulses) of 0.5–1.0 Gy given usually at 1–1.5-h intervals, and dose distributions using PDR or LDR can be made virtually identical [15]. It was shown that 1 Gy cycles at intervals of 1–3 h (varied among animal studies) resulted in similar biological effects from the same total doses delivered continuously at 0.50–0.75 Gy per hour. Higher doses per cycle and different cycle intervals resulted in deviations from equivalence because of biphasic repair, in particular for late-reacting tissues [16,17]. The therapeutic ratio of PDR vs LDR depends on cycle dose size and interval and tissue repair characteristics [α/β ratios and repair half-times (T1/2)]. In normal tissues with a T1/2<0.5-h component, PDR may be more damaging than LDR [18], but the effect should be reduced if the dose per cycle is <1 Gy [16,19].The present study reports calculations of LDR-equivalent PDR doses using biphasic vs monophasic repair kinetics for both the tumour and for the OAR, and the consequent implications.  相似文献   

14.

Objective:

The purpose of this study was to retrospectively evaluate the sensitivity, specificity and accuracy of identifying methamphetamine (MA) internal payloads in “drug mules” by plain abdominal digital radiography (DR).

Methods:

The study consisted of 35 individuals suspected of internal MA drug containers. A total of 59 supine digital radiographs were collected. An overall calculation regarding the diagnostic accuracy for all “drug mules” and a specific evaluation concerning the radiological appearance of drug packs as well as the rate of clearance and complications in correlation with the reader''s experience were performed. The gold standard was the presence of secured drug packs in the faeces.

Results:

There were 16 true-positive “drug mules” identified. DR of all drug carriers for Group 1 (forensic imaging experienced readers, n = 2) exhibited a sensitivity of 100%, a mean specificity of 76.3%, positive predictive value (PPV) of 78.5%, negative predictive value (NPV) of 100% and a mean accuracy 87.2%. Group 2 (inexperienced readers, n = 3) showed a lower sensitivity (93.7%), a mean specificity of 86%, a PPV of 86.5%, an NPV of 94.1% and a mean accuracy of 89.5%. The interrater agreement within Group 1 was 0.72 and within Group 2 averaged to 0.79, indicating a fair to very good agreement.

Conclusion:

DR is a valuable screening tool in cases of MA body packers with huge internal payloads being associated with a high diagnostic insecurity. Diagnostic insecurity on plain films may be overcome by low-dose CT as a cross-sectional imaging modality and addressed by improved radiological education in reporting drug carriers on imaging.

Advances in knowledge:

Diagnostic signs (double-condom and halo signs) on digital plain radiography are specific in MA “drug mules”, although DR is associated with high diagnostic insecurity and underreports the total internal payload.For the past decade, significant worldwide manufacturing of amphetamine-type stimulants has been reported to the United Nations Office on Drugs and Crime, Vienna, Austria, with a predominance of methamphetamine (MA) and its derivatives, which are also known as “syabu” or “ice”, throughout East and South East Asia.1 In this region, the use of this synthetic drug is more prevalent than that of cocaine or heroin, which are more common in relatively developed areas, such as Europe and the USA.2 During the course of this development, an increase in the number of drug carriers being intercepted by law enforcement at the borders of Malaysia has been observed. Drug carriers or “drug mules” are generally referred to as a human harbouring internal illicit drug packet(s). Internal body concealment of illegal drugs is one of the methods used to smuggle this illicit drug across the border.3,4 “Drug mules” are generally known as body packers.5,6 However, for correct terminology, one should differentiate between the terms body packer, body pusher and body stuffer. A body packer swallows a large amount of specially prepared drug packets to smuggle the packets in their gastrointestinal tract across a national border.5,6 A body pusher hides a few containers in easily accessible body cavities, such as the rectum or vagina. Body stuffers, including traffickers and users, ingest intentionally small amounts of loosely wrapped drug pellets (typically initially hidden in the mouth), usually immediately before an unexpected encounter with law enforcement.510The generally accepted radiological examination is a plain abdominal radiograph in the supine projection.46 This technique is widely available at a low cost and is a simple method of detecting drug-filled packets within the alimentary tract. Radiation exposure to the patient is relatively moderate. In the literature, the detection rate for drug-filled packets is highly variable, and sensitivities from 58.3% to 90% have been reported.4,5,11 Hence, plain abdominal radiography is a flawed screening method for identifying “drug mules”. Examining the bowel for foreign bodies, such as drug containers with variable sizes and radiodensities, is problematic, even for an experienced radiologist because the drug-filled packets may have an appearance similar to that of stool and gas and may be superimposed. Specific appearances described in the literature, such as the “double-condom”, “halo” and “rosette” signs, may be diagnostic for drug packages but are not necessarily so.46,1113 Other modalities employed worldwide for the identification of body packers include CT, ultrasound, MRI and low-dose linear slit digital radiography (LSDR or LODOX®; Lodox Systems, Johannesburg, South Africa).4,5,1418Recent research has mainly concentrated on cocaine and heroin drug trafficking, which occurs predominantly in Western countries.3,4,6,7,11,14,19 There is little research on the accuracy of plain abdominal radiography in MA drug carriers, although there has been a significant increase of MA in Asia, accompanied by draconian legal measures in cases of drug trafficking.1,2 The purpose of this study was to retrospectively evaluate the sensitivity, specificity and accuracy of plain abdominal digital radiography (DRL) for identifying the internal payloads of MA in “drug mules”.  相似文献   

15.

Objective:

To compare the capability of differentiation of small-cell lung cancer (SCLC) from non-SCLC (NSCLC) between diffusion-weighted imaging (DWI) and short tau inversion recovery (STIR) turbo spin-echo imaging.

Methods:

The institutional review board of Kobe University Hospital, Kobe, Japan, approved this study, and written informed consent was obtained from each patient. 49 patients with NSCLC (30 males and 19 females; mean age, 66.8 years) and 7 patients with SCLC (5 males and 2 females; mean age, 68.6 years) enrolled and underwent DWI and STIR. To quantitatively differentiate SCLC from NSCLC, apparent diffusion coefficient (ADC) values on DWI and contrast ratios (CRs) between cancer and muscle on STIR were evaluated. ADC values and CRs were then compared between the two cell types by Mann–Whitney''s U-tests, and the diagnostic performances were compared by McNemar''s test.

Results:

There were significant differences of mean ADC values (p < 0.001) and mean CRs (p = 0.003). With adopted threshold values, the specificity (85.7%) and accuracy (85.7%) of DWI were higher than those of STIR (specificity, 63.3%; p = 0.001 and accuracy, 66.1%; p = 0.001). In addition, the accuracy of combination of both indexes (94.6%; p = 0.04) could significantly improve as compared with DWI alone.

Conclusion:

DWI is more useful for the differentiation of SCLC from NSCLC than STIR, and their combination can significantly improve the accuracy in this setting.

Advances in knowledge:

Pulmonary MRI, including DWI and STIR, had a potential of the suggestion of the possibility as SCLC.Lung cancer is the most common cause of cancer-related death among both males and females worldwide.1 Lung cancers are divided into non-small-cell cancer (NSCLC) and small-cell lung cancer (SCLC), and the differentiation between SCLC and NSCLC is important in clinical practice because their therapeutic strategies, clinical course and prognoses are different.2 In general, SCLC is usually determined with extensive hilar and mediastinal lymphadenopathy,3 and these cancers are mainly treated by chemotherapy or chemoradiotherapy.2,4On the other hand, 5–10% of patients with SCLC were diagnosed as having solitary pulmonary nodules.5,6 In this situation, the assessments of distant metastases before treatment play an important role in deciding the treatment. At present, although there are some different reports for patients with NSCLC regarding the assessment of distant metastases before surgery,79 it is important to assess the distant metastases of these patients with SCLC because SCLC is known for its rapid doubling time, high growth fraction and early development of metastatic disease.1012 If patients with SCLC are diagnosed at Stage I or possibly Stage II, clinicians consider their treatment as surgery and/or neoadjuvant chemotherapy.1315 Therefore, the differentiation between SCLC and NSCLC and the suggestion of the possibility of SCLC may be important in routine clinical practice. However, the differentiation of SCLC from NSCLC is difficult on CT and positron emission tomography (PET) or PET/CT,5,6,16 and fiberoptic bronchoscopy and percutaneous biopsy are recommended, although their diagnostic sensitivities range from 67% to 100%.1719Recently, the image quality and diagnostic capability of chest MRI has improved because of the advancement of MR systems and sequences, and short tau inversion recovery (STIR) turbo spin-echo (SE) imaging and diffusion-weighted imaging (DWI) have been reported as useful in differentiating malignant nodules and lymph nodes from benign ones in several articles.2025 Meanwhile, the utilities of chest MRI, including STIR and DWI, have been reported,26 and, in addition, meta-analysis report for pulmonary nodules by means of DWI have been published.27 However, to the best of our knowledge, there have been only reports of chest DWI regarding the differentiation between SCLC and NSCLC,22 but no major studies have reported a direct comparison of the use of DWI and STIR in chest MRI for the assessment of differentiation between SCLC and NSCLC. We hypothesized that both DWI and STIR were useful MR sequences for differentiation of SCLC from NSCLC and their combination might improve the differentiation capabilities. The aim of this study was to evaluate the diagnostic performances of DWI and STIR for differentiating between SCLC and NSCLC.  相似文献   

16.

Objective:

To evaluate dual-energy CT (DECT) findings of pulmonary ischaemic–reperfusion injury (PIRI) and its pathophysiological correlation in the canine model.

Methods:

A PIRI model was established in 11 canines, utilizing closed pectoral balloon occlusion. Two control canines were also included. For the PIRI model, the left pulmonary artery was occluded with a balloon, which was deflated and removed after 2 h. DECT was performed before, during occlusion and at 2, 3 and 4 h thereafter and was utilized to construct pulmonary perfusion maps. Immediately after the CT scan at the fourth hour post reperfusion, the canines were sacrificed, and lung specimens were harvested for pathological analysis. CT findings, pulmonary artery pressure and blood gas results were then analysed.

Results:

Data at every time point were available for 10 animals (experimental group, n = 8; control group, n = 2). Quantitative measurements from DECT pulmonary perfusion maps found iodine attenuation values of the left lung to be the lowest at 2 h post embolization and the highest at 1 h post reperfusion. In the contralateral lung, perfusion values also peaked at 1 h post reperfusion. Continuous hypoxia and acid–based disorders were observed during PIRI, and comprehensive analysis showed physiological changes to be worst at 3 h post reperfusion.

Conclusion:

DECT pulmonary perfusion mapping demonstrated pulmonary perfusion of the bilateral lungs to be the greatest at 1 h post reperfusion. These CT findings corresponded with pathophysiological changes.

Advances in knowledge:

DECT pulmonary perfusion mapping can be used to evaluate lung ischaemia–reperfusion injury.Ischaemia–reperfusion injury (IRI) occurs under a variety of clinical conditions, including lung and/or cardiac transplantation, cardiopulmonary bypass, pulmonary resection, re-expansion pulmonary oedema, shock, cardiopulmonary resuscitation and pulmonary embolism.13 Pulmonary embolism is a common cause of pulmonary IRI (PIRI), and the incidence of pulmonary embolism is increasing4,5 with a mortality rate of up to 30%.6 With timely identification and treatment of pulmonary embolism, mortality rates can be reduced to <10%.7 However, reperfusion after treatment for lung ischaemia can also cause serious complications, such as haemorrhage and pulmonary oedema.8 Therefore, it is important to understand both the pathophysiological and imaging appearances of pulmonary IRI. Lung transplantation is also a common cause for PIRI following pulmonary arterial occlusion. Currently, the incidence of PIRI following transplantation is estimated at up to 25%. Post transplantation, PIRI can lead to insufficiency of the primary lung graft, delayed graft function, acute or chronic rejection (e.g. pulmonary oedema and acute respiratory failure), and increased early post-operative mortality and graft failure.9,10CT is currently the predominant modality for the imaging assessment of thoracic disorders, including PIRI. Dual-energy CT (DECT) allows simultaneous acquisition of dual-energy data sets, allowing for decomposition of the scanned entity based on differences in attenuation between air, soft tissue and iodine.11 One application of this principle in pulmonary imaging is the ability to obtain iodine maps demonstrating the distribution of pulmonary perfusion. The use of CT perfusion mapping has been shown to be relatively sensitive and highly specific for the detection of pulmonary emboli.12Recent research into PIRI has focused on the pathological and molecular biological mechanisms.1316 To date, there are few reports on imaging and pathophysiological findings in PIRI.17,18 CT perfusion findings in PIRI have also not yet been described. The aim of this study was to assess PIRI imaging and pathophysiological findings in a canine model.  相似文献   

17.

Objective:

To quantify the test–retest repeatability of mean diffusivity (MD) and fractional anisotropy (FA) derived from diffusion tensor imaging (DTI) tractography in a cohort of paediatric patients with localization-related epilepsy.

Methods:

30 patients underwent 2 DTI acquisitions [repetition time/echo time (ms), 7000/90; flip, 90°; b-value, 1000 s mm−2; voxel (mm), 2 × 2 × 2]. Two observers used Diffusion Toolkit and TrackVis (www.trackvis.org) to segment and analyse the following tracts: corpus callosum, corticospinal tracts, arcuate fasciculi, inferior longitudinal fasciculi and inferior fronto-occipital fasciculi. Mean MD and mean FA were calculated for each tract. Each observer independently analysed one of the DTI data sets for every patient.

Results:

Segmentation identified all tracts in all subjects, except the arcuate fasciculus. There was a highly consistent relationship between repeated observations of MD (r = 0.993; p < 0.0001) and FA (r = 0.990; p < 0.0001). For each tract, coefficients of variation ranged from 0.9% to 2.1% for MD and from 1.5% to 2.8% for FA. The 95% confidence limits (CLs) for change ranged from 2.8% to 6% for MD and from 4.3% to 8.6% for FA. For the arcuate fasciculus, Cohen''s κ for agreement between the observers (identifiable vs not identifiable) was 1.0.

Conclusion:

We quantified the repeatability of two commonly utilized scalar metrics derived from DTI tractography. For an individual patient, changes greater than the repeatability coefficient or 95% CLs for change are unlikely to be related to variability in their measurement.

Advances in knowledge:

Reproducibility of these metrics will aid in the design of future studies and might one day be used to guide management in patients with epilepsy.Epilepsy is a common neurological condition defined by recurrent unprovoked seizures that affects 1% of the population, including 1 in 200 children.1,2 Unlike in adults, developmental lesions predominate as the source of seizures in children; in particular, focal cortical dysplasia is the most common anatomical substrate for intractable epilepsy in the paediatric population.3 A high proportion of epilepsies occurring in the setting of cortical malformations are pharmacoresistant,4 highlighting the importance of alternative management strategies. In appropriately selected patients who fail medical management, surgical resection of the dysplastic cortex can be curative. In such cases, pre-operative identification and complete resection of the structural lesion are important prognostic factors.5,6 Decision making surrounding the pursuit of invasive alternatives is rarely straightforward, however, and in practice relies heavily on supplementary information provided by novel diagnostic techniques.Although surgical management is an attractive option for many patients with focal seizures, medical therapy continues to be adopted as the “safe” strategy in a significant portion of this population. However, there is good evidence to suggest that ongoing seizures and treatment with antiseizure medication might be associated with progressive alterations in white matter integrity.79 Furthermore, these same ongoing processes can contribute to progressive functional decline.10,11 As such, the ability to confidently identify progression of network alterations in an individual patient with epilepsy, whether on the basis of ongoing seizure activity, antiseizure medication or both, would be of great value to informed decision making surrounding potential surgical intervention.With the advent of diffusion-weighted imaging (DWI), the microstructural properties of a tissue of interest can be non-invasively probed at a spatial scale that is otherwise unattainable using even the most advanced structural MR techniques. Diffusion tensor imaging (DTI) is a variation on the theme of DWI, which quantifies water motion in three orthogonal dimensions and, therefore, is better able to capture the anisotropic tendencies of diffusion in highly organized tissues, such as cerebral white matter.12 Numerous scalar metrics can be derived from the tensor; the most commonly referenced are mean diffusivity (MD) and fractional anisotropy (FA). MD provides a measure of overall incoherent motion within a voxel without regard for direction and reflects tissue organization at the cellular level.13 Increased MD is a common manifestation of white matter pathology of diverse aetiology.1416 By contrast, FA provides a measure of the degree to which a single direction of water motion dominates overall diffusivity in a voxel. As such, FA has been shown to be a relatively robust measure of white matter integrity.1721 Diffusion tractography is an extension of DTI in which the directional tendencies of water diffusion are used to create three-dimensional representations of white matter tracts based on their structural coherence.22,23 In many instances, the functional role of the constructed pathways is at least in part known, which enables assessment of brain parenchymal abnormalities in terms of functional systems.16,24DTI and diffusion tractography already occupy a prominent place in epilepsy research, and they are increasingly used to guide clinical management of epilepsy patients.7,2530 Although preliminary results are promising, a thorough understanding of the test–retest reproducibility of metrics derived from DTI will be crucial to the widespread application of this technique. Such knowledge would inform the design of both cross-sectional and longitudinal studies, including appropriate sample size selection. Furthermore, the clinical utility of such quantitative techniques will be predicated on an understanding of their intrinsic variability at the level of the individual. In particular, an understanding of what represents true difference at the individual level will be required to ascribe significance to changes in these metrics that occur in an individual patient. To date, however, the reproducibility of quantitative metrics derived from tractography has not been widely studied and, in particular, there are very few data from either the paediatric or epilepsy populations.31 The goal of this study, therefore, was to measure the repeatability of MD and FA derived from DTI tractography in a cohort of paediatric patients with localization-related epilepsy.  相似文献   

18.

Objective:

To describe multidetector CT imaging features of solid pseudopapillary tumours (SPTs) in male patients and to compare these imaging features with those found in female patients.

Methods:

The institutional review board approved this retrospective study. We included the CT images of 72 patients (M:F = 12:60; mean age, 35.0 years) diagnosed with SPT by histology. CT images were reviewed on the following: location of the tumour, maximal diameter, shape, margin and the fraction of the tumour composition. Statistical differences in CT imaging features were analysed.

Results:

Male patients with SPTs were significantly older than female patients (42.4 years vs 33.4 years, p = 0.0408) and the mean size of the SPTs in male patients was larger (6.3 cm vs 4.6 cm, p = 0.0413) than that of SPTs in female patients. Lobulated shape of the SPTs was most frequent in male patients, whereas oval shape was most frequent in female patients (p = 0.0133). SPTs in male patients tended to have a solid component (p = 0.0434). Progressive enhancement in the solid portion of the tumour was seen in 9 (81.8%) of 11 SPTs in male patients and in 30 (79.0%) of 38 SPTs in female patients on multiphasic CT.

Conclusion:

The imaging features of SPTs in male patients usually appeared as a somewhat large-sized solid mass with a lobulated margin and progressive enhancement. These imaging features may help to differentiate SPTs from other pancreatic tumours for their proper management.

Advances in knowledge:

SPTs in male patients appear as somewhat large-sized solid masses with lobulated margins, and this form occurs more frequently in older male patients than in female patients.Solid pseudopapillary tumour (SPT) of the pancreas is a rare low-grade malignant neoplasm accounting for only 1–2% of all pancreatic tumours.13 Synonyms for this neoplasm include solid and cystic tumours, solid and papillary epithelial neoplasms, solid cystic papillary tumour, papillary cystic neoplasm, papillary cystic epithelial neoplasm, papillary cystic tumour or Frantz''s tumour.3,4SPT is known to occur preferentially in young females and has a favourable prognosis. The characteristic imaging features of SPTs include encapsulation, solid and cystic components and peripheral calcification.1,3,4 Although the imaging characteristics of SPTs have been well described in recent years,3,5 it remains uncertain if the features of SPT occurring in males differ from those in females.Machado et al6 and Takahashi et al7 described distinctive clinicopathological characteristics of SPTs occurring in males. The purpose of this study was to describe multidetector CT (MDCT) imaging features of SPTs in male patients and to compare these features with those of female patients.  相似文献   

19.

Objective:

A planning target volume (PTV) margin formula for hypofractionated intracranial stereotactic radiotherapy (SRT) has been proposed under cone beam CT (CBCT) image guidance with a six-degrees-of-freedom (6-DOF) robotic couch.

Methods:

CBCT-based registration using a 6-DOF couch reportedly led to negligibly small systematic positioning errors, suggesting that each in-treatment positioning error during the treatment courses for the patients employing this combination was predominantly caused by a random gaussian process. Under this assumption, an anisotropic PTV margin for each axis was formulated based on a gaussian distribution model. 19 patients with intracranial lesions who underwent additional post-treatment CBCT were consecutively selected, to whom stereotactic hypofractionated radiotherapy was delivered by a linear accelerator equipped with a CBCT imager, a 6-DOF couch and a mouthpiece-assisted mask system. Time-averaged patient-positioning errors during treatment were estimated by comparing the post-treatment CBCT with the reference planning CT images.

Results:

It was suggested that each histogram of the in-treatment positioning error in each axis would approach each single gaussian distribution with a mean of zero. The calculated PTV margins in the x, y and z directions were 0.97, 1.30 and 0.88 mm, respectively.

Conclusion:

The empirical isotropic PTV margin of 2 mm used in our facility for intracranial SRT was consistent with the margin calculated by the proposed gaussian model.

Advances in knowledge:

We have proposed a PTV margin formula for hypofractionated intracranial SRT under CBCT image guidance with a 6-DOF robotic couch.Frameless radiotherapy for treating intracranial lesions has been widely adopted under the guidance of on-board cone beam CT (CBCT) and a mask system with a six-degrees-of-freedom (6-DOF) robotic couch13 or a semi-robotic couch including manual angle adjustments.4 Reported maximum registration errors along any Cartesian co-ordinate axis were 0.5 mm for a phantom;1 and 1.0 or 3.2 mm (mask dependent),2 2.0 3 and 1.2 mm4 for patients. The mean ± standard deviation (SD) along any Cartesian co-ordinate axis was 0.07 ± 0.17 mm for a phantom based on 12 plans and 5 repeated CBCT acquisitions,1 0.2 ± 0.4 mm for 10 patients with 6 fractions3 and 0.4 ± 0.3 mm for a phantom and 0.5 ± 0.3 mm for patients including manual couch angle adjustments.4 Meyer et al1 stated that there was no systematic error because they observed a small mean error for their phantom study.Margins between clinical target volumes (CTVs) and planning target volumes (PTVs) are often calculated using a formula proposed by van Herk et al.5,6 This formula employed two independent statistical models including a patient-to-patient variation model that gives a mean preparation error in all fractions for each patient, and a random error model during treatment delivery owing to random tumour movement. A patient population coverage probability of 90% in a facility was calculated by the patient-to-patient variation model, and the random error model was used to add further margins by increasing penumbra widths. Our intracranial stereotactic radiotherapy (SRT) utilizes an Elekta Synergy® (Elekta AB, Stockholm, Sweden) linear accelerator (linac) equipped with a CBCT imager, XVI and a 6-DOF robotic couch, HexaPOD™ (Elekta AB), which are identical to the system that Meyer et al1 described. Consequently, our study can be based on the small mean preparation error reported by Meyer et al, and the above margin model may not be applicable. In addition, the previous margin model assumed that the tumour was spherical, and the margin was defined in the radial direction of the spherical co-ordinate system. For example, Guckenberger et al2 calculated the PTV margin in the radial direction using registration results for 47 patients with various treatment sites and fixation means, leading to a PTV margin of 1.7 mm that achieved 90% population coverage. Meanwhile, a more accurate margin formula in the Cartesian co-ordinate system that complies with patient couch movements was proposed, in which the margins were anisotropically defined along the x, y and z directions.7The purpose of this study was to propose a PTV margin formula as per the Cartesian co-ordinate system for hypofractionated intracranial SRT under CBCT image guidance with a 6-DOF robotic couch.  相似文献   

20.

Objective:

To compare the performance of the 15-G internally cooled electrode with that of the conventional 17-G internally cooled electrode.

Methods:

A total of 40 (20 for each electrode) and 20 ablation zones (10 for each electrode) were made in extracted bovine livers and in in vivo porcine livers, respectively. Technical parameters, three dimensions [long-axis diameter (Dl), vertical-axis diameter (Dv) and short-axis diameter (Ds)], volume and the circularity (Ds/Dl) of the ablation zone were compared.

Results:

The total delivered energy was higher in the 15-G group than in the 17-G group in both ex vivo and in vivo studies (8.78 ± 1.06 vs 7.70 ± 0.98 kcal, p = 0.033; 11.20 ± 1.13 vs 8.49 ± 0.35 kcal, p = 0.001, respectively). The three dimensions of the ablation zone had a tendency to be larger in the 15-G group than in the 17-G group in both studies. The ablation volume was larger in the 15-G group than in the 17-G group in both ex vivo and in vivo studies (29.61 ± 7.10 vs 23.86 ± 3.82 cm3, p = 0.015; 10.26 ± 2.28 vs 7.79 ± 1.68 cm3, p = 0.028, respectively). The circularity of ablation zone was not significantly different in both the studies.

Conclusion:

The size of ablation zone was larger in the 15-G internally cooled electrode than in the 17-G electrode in both ex vivo and in vivo studies.

Advances in knowledge:

Radiofrequency ablation of hepatic tumours using 15-G electrode is useful to create larger ablation zones.Radiofrequency ablation (RFA) is the most widely used local ablation technique for the management of primary and metastatic liver tumours. However, previous studies have reported that RFA showed a relatively higher local tumour progression rate than did hepatic resection.1,2 One of the most important factors affecting local tumour progression was insufficient tumour-free ablation margin of hepatic parenchyma around the tumour margin.36Several strategies have been developed to obtain sufficient ablation margin. In the aspect of RFA techniques, overlapping technique and combined treatment with transcatheter arterial chemoembolization can be used.79 Another strategy is to use switching monopolar, bipolar or multipolar modes to deliver radiofrequency (RF) energy more efficiently.10,11 Sufficient ablation margin can also be achieved by more efficient electrodes: internally cooled electrode increases the size of ablation zone by preventing charring around the electrode tip.12,13 Perfusion electrodes can also enlarge the ablation zone by increasing electrical conductance and thermal conductivity.1416The diameter of an electrode is also known to be associated with the size of the ablation zone. Theoretically, as the diameter of an electrode becomes larger, the contact surface of the electrode with the surrounding tissue becomes bigger, thereby increasing the active electric field.17,18 As a result, an electrode with a larger diameter is likely to create a larger ablation zone. In a previous study, Goldberg et al17 reported that the extent of coagulation necrosis by RFA increases as the diameter of an electrode increases through an in vivo experimental study. However, this study was performed with an electrode without an internal cooling system. Recently, a clinical study comparing therapeutic efficacy and safety between 15-G and 17-G internally cooled electrodes of RFA for hepatocellular carcinoma was published.19 According to that study, the 15-G internally cooled electrode created a larger ablation volume than did the 17-G electrode. However, the study was limited by selection bias owing to the retrospective study design. In addition, the ablation protocol was not exactly the same between the two groups. Therefore, the issue whether an internally cooled electrode with a larger diameter creates a larger ablation volume should be verified with ex vivo and in vivo experimental studies.The purpose of this experimental study was to compare the performance of the 15-G internally cooled RF electrode with that of the conventional 17-G electrode in both ex vivo and in vivo studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号