首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Objective

This study was performed to evaluate the biocompatibility of nine types of pure metal ingots (Ag, Al, Cr, Cu, Mn, Mo, Nb, V, Zr) and 36 experimental titanium (Ti) alloys containing 5, 10, 15, and 20 wt% of each alloying element.

Methods

The cell viabilities for each test group were compared with that of CP-Ti using the WST-1 test and agar overlay test.

Results

The ranking of pure metal cytotoxicity from most potent to least potent was as follows: Cu > Al > Ag > V > Mn > Cr > Zr > Nb > Mo > CP-Ti. The mean cell viabilities for pure Cu, Al, Ag, V, and Mn were 21.6%, 25.3%, 31.7%, 31.7%, and 32.7%, respectively, which were significantly lower than that for the control group (p < 0.05). The mean cell viabilities for pure Zr and Cr were 74.1% and 60.6%, respectively (p < 0.05). Pure Mo and Nb demonstrated good biocompatibility with mean cell viabilities of 93.3% and 93.0%, respectively. The mean cell viabilities for all the Ti-based alloy groups were higher than 80% except for Ti–20Nb (79.6%) and Ti–10V (66.9%). The Ti–10Nb alloy exhibited the highest cell viability (124.8%), which was higher than that of CP-Ti. Based on agar overlay test, pure Ag, Cr, Cu, Mn, and V were ranked as ‘moderately cytotoxic’, whereas the rest of the tested pure metals and all Ti alloys, except Ti–10V (mild cytotoxicity), were ranked as ‘noncytotoxic’.

Significance

The results obtained in this study can serve as a guide for the development of new Ti-based alloy implant systems.  相似文献   

2.
PurposeThe purpose of this study was to compare the tensile strength of commercially pure titanium dowels and cores cemented with zinc phosphate or resin cements.MethodsTwenty-one extracted human canines were endodontically treated. The root preparations were accomplished using Largo reamers (10 mm in depth and 1.7 mm in diameter). Acrylic resin patterns for the dowel and cores were made, and specimens were cast in commercially pure titanium (n = 7) and divided in three groups: TZ–CP Ti dowels luted with zinc phosphate luting agent, TP–CP Ti dowels luted with Panavia F and TR–CP Ti dowels luted with RelyX U100. Tensile strengths were measured in a universal testing machine at a crosshead speed of 0.5 mm/min. The results (N) were statistically analyzed by ANOVA and Tukey tests (α = 0.01).ResultsThe ANOVA indicated that there were significant differences among the groups tested. A Tukey multiple comparison procedure was performed and revealed statistically significant higher retention values for the dowel luted with RelyX U100 when compared with zinc phosphate or Panavia F.ConclusionCast commercially pure titanium dowels and cores fixed with RelyX U100 cement presented superior bond strength retention when compared to zinc phosphate and Panavia F.  相似文献   

3.
ObjectivesTo investigate the bond strength between cpTi and low fusing porcelains after different treatments.Methods72 patterns were covered with a ceramic coating and invested with phosphate-bonded material (group A), another 72 were invested with magnesia material (group B) and all cast with cpTi. 31 solid castings were selected from each group. The castings of group B were ground and sandblasted, while the castings of group A were only sandblasted. Aluminum content of the metal surface was determined by EDS and castings were submitted to a 3-point bending test to determine the modulus of elasticity (E). The porcelains Duceratin Plus, Noritake Ti22 and Triceram were applied respectively and specimens were submitted to a 3-point bending test. The fracture mode and the remaining porcelain were determined by optical microscopy and SEM/EDS. Bond strength and fracture mode were calculated by two-way ANOVA.ResultsThe E of groups A and B was 98.3 GPa and 98.6 GPa respectively. The bond strength was 26 ± 3 MPa (Duceratin Plus), 28 ± 3 MPa (Noritake Ti22), 27 ± 2 MPa (Triceram) for group A and 24 ± 1 MPa, 29 ± 2 MPa, 27 ± 1 MPa for group B respectively. No significant differences were found for the same porcelain between the two groups (p < 0.05). A significant difference was found between Duceratin Plus and Noritake Ti22, for group B (p < 0.05). The mode of failure was mainly adhesive for all specimens. A significant reduction in aluminum was recorded in all subgroups.SignificanceThe special coating of patterns makes the Ti casting procedure inexpensive, without reducing the metal–ceramic bond strength.  相似文献   

4.
《Dental materials》2014,30(12):e384-e395
ObjectivesThe aim of this study was to evaluate the bone tissue response to fiber-reinforced composite (FRC) in comparison with titanium (Ti) implants after 12 weeks of implantation in cancellous bone using histomorphometric and ultrastructural analysis.Materials and methodsThirty grit-blasted cylindrical FRC implants with BisGMA–TEGDMA polymer matrix were fabricated and divided into three groups: (1) 60 s light-cured FRC (FRC-L group), (2) 24 h polymerized FRC (FRC group), and (3) bioactive glass FRC (FRC–BAG group). Titanium implants were used as a control group. The surface analyses were performed with scanning electron microscopy and 3D SEM. The bone–implant contact (BIC) and bone area (BA) were determined using histomorphometry and SEM. Transmission electron microscopy (TEM) was performed on Focused Ion Beam prepared samples of the intact bone–implant interface.ResultsThe FRC, FRC–BAG and Ti implants were integrated into host bone. In contrast, FRC-L implants had a consistent fibrous capsule around the circumference of the entire implant separating the implant from direct bone contact. The highest values of BIC were obtained with FRC–BAG (58 ± 11%) and Ti implants (54 ± 13%), followed by FRC implants (48 ± 10%), but no significant differences in BIC or BA were observed (p = 0.07, p = 0.06, respectively). TEM images showed a direct contact between nanocrystalline hydroxyapatite of bone and both FRC and FRC–BAG surfaces.ConclusionFiber-reinforced composite implants are capable of establishing a close bone contact comparable with the osseointegration of titanium implants having similar surface roughness.  相似文献   

5.
《Archives of oral biology》2014,59(8):829-834
ObjectiveThe aim of the present study is to assess salivary flow rate in the subjects who were on antidepressant medications and its comparison with healthy controls and assessment of unstimulated salivary flow rate by modified Schirmer test (MST) and volumetric method (spitting method) for evaluation of xerostomia and whether any correlation exists between two methods.Material and MethodsThirty subjects who were on antidepressants were divided into two groups: tricyclic antidepressants (TCA) and selective sertonin reuptake inhibitors (SSRI) of 15 each, compared with 30 age and gender matched controls. Unstimulated salivary flow rate was measured by both MST and spitting method.ResultsThe unstimulated salivary flow rate measured by MST at the end of 3rd minute was 13.7 ± 10.08, 19.86 ± 8.95 and 31.0 ± 5.4 mm and by spitting method was 0.12 ± 0.07, 0.19 ± 0.10 and 0.30 ± 0.75 ml/min in TCA, SSRI and controls respectively (p < 0.001). The Pearson correlation coefficient of r = 0.85 shows excellent correlation between the two screening tests. Sensitivity and Specificity of MST was 90.9% and 31.5%.ConclusionSalivary flow rate was less in antidepressant subjects when compared to the healthy controls. Results of the present study showed an excellent correlation excellent correlation between the two screening tests which suggests that MST can be routinely used as chair-side screening tool to evaluate hyposalivation which is time saving, patient friendly and specific of salivary secretions.  相似文献   

6.
《Archives of oral biology》2014,59(8):808-814
ObjectivesTo evaluate the antimicrobial activity of Arctium lappa L. extract on Staphylococcus aureus, S. epidermidis, Streptococcus mutans, Candida albicans, C. tropicalis and C. glabrata. In addition, the cytotoxicity of this extract was analyzed on macrophages (RAW 264.7).DesignBy broth microdilution method, different concentrations of the extract (250–0.4 mg/mL) were used in order to determine the minimum microbicidal concentration (MMC) in planktonic cultures and the most effective concentration was used on biofilms on discs made of acrylic resin. The cytotoxicity A. lappa L. extract MMC was evaluated on RAW 264.7 by MTT assay and the quantification of IL-1β and TNF-α by ELISA.ResultsThe most effective concentration was 250 mg/mL and also promoted significant reduction (log10) in the biofilms of S. aureus (0.438 ± 0.269), S. epidermidis (0.377 ± 0.298), S. mutans (0.244 ± 0.161) and C. albicans (0.746 ± 0.209). Cell viability was similar to 100%. The production of IL-1β was similar to the control group (p > 0.05) and there was inhibition of TNF-α (p < 0.01).ConclusionsA. lappa L. extract was microbicidal for all the evaluated strains in planktonic cultures, microbiostatic for biofilms and not cytotoxic to the macrophages.  相似文献   

7.
ObjectiveMonomers like BisGMA (Bisphenol-A-glycidyldimethacrylate) and comonomers like TEGDMA (triethyleneglycoldimethacrylate) are used in dental restorative materials in order to build up the three-dimensional network of filling materials. Since earlier investigations revealed uptake and subsequent metabolism of unpolymerized remainders of (co)monomers, the present experiment investigates the metabolic urine pattern of guinea pigs (n = 4) after application of TEGDMA or BisGMA (each dose = 0.02 mmol/kg body weight = 100%), respectively.MethodsFor the investigations BisGMA was pre-dissolved in DMSO and subsequently diluted with 0.9% NaCl solution (final DMSO concentration 1%) and TEGDMA was dissolved in 0.9% NaCl solution. The solutions were administered with a gastric tube into the animals. Control animals received either 0.9% NaCl or 0.9% NaCl solution with 1% DMSO solution.ResultsAfter 24 h in collected urine the following metabolites were identified. After administration of TEGDMA (mean relative concentration of administered substances) ± s.d. [%]; n = 4): unchanged TEGDMA: 12 ± 1.5%, MA: 2.4 ± 0.8%, and triethyleneglycol: 35 ± 2.2%. After administration of BisGMA (mean ± s.d. [%]; n = 4): unchanged BisGMA: 11.4 ± 2.7%, MA: 2.2 ± 0.6%, and bisphenol-A-bis(2,3-dihydroxypropyl)ether: 60.1 ± 5.2%).ConclusionNo further metabolites like the previously identified intermediate 2,3-epoxymethacrylic acid and derived reaction products were identified in the urine, indicating that these metabolites must have reacted further.  相似文献   

8.
PurposeTo investigate the effects of titanium (Ti) ions on the cell viability, the cell differentiation and the gene expressions related to bone resorption including Receptor Activator of NF-κB Ligand (RANKL) and Osteoprotegerin (OPG) in the tissues around dental implants, the osteoblast-, osteoclast-, and gingival epithelial-like cells were exposed to Ti ions.MethodsAn MTS assay was carried out to evaluate the viabilities of osteoblast-like MC3T3-E1, osteoclast-like RAW264.7 and epithelial cell-like GE-1 cells. The gene expressions in these cells were analyzed by the use of RT-PCR and real-time quantitative RT-PCR.ResultsTi ions in the concentration range 1–9 ppm had little effect on the viabilities of MC3T3-E1, RAW264.7 and GE-1, whereas 20 ppm Ti ions significantly decreased the viabilities of all cells. Analyses of RT-PCR and real-time quantitative RT-PCR data revealed that Ti ions at 9 ppm remarkably inhibited the expressions of Runx2, Osterix and type I collagen in MC3T3-E1. In RAW264.7, Ti ions showed no effects on the levels of mRNAs for TRAP and cathepsin K enhanced by RANKL. Ti ions at the range of 1–9 ppm showed no effects on the levels of mRNAs for RANKL and OPG in GE-1, while Ti ions at 9 ppm enhanced the expression of these genes in MC3T3-E1.ConclusionsThese results, taken together, suggested that Ti ions show the biological effects, both on the viabilities of osteoblast and osteoclast and on the differentiation of either the osteoblastic or osteoclastic cells, which may influence the prognosis of dental implants.  相似文献   

9.
ObjectivesThe purpose of this study was to investigate the corrosion behavior of Ti–Ag alloys in artificial saliva solutions.MethodsThe corrosion behavior of experimental Ti–Ag alloys in artificial saliva was examined by means of potentiodynamic polarization measurements. The surface passive film formed was analyzed by means of X-ray photoelectron spectroscopy (XPS) and X-ray diffraction (XRD) methods.ResultsThe alloys were found to develop surface passive films after immersion for 1.8 × 103 s. In comparison with commercially pure Ti, the Ti–Ag alloys exhibited better corrosion resistance with lower anodic current densities, larger polarization resistances, and higher open-circuit potentials. The passive film formed was predominantly composed of TiO2, as determined by XPS. When fluoride ions were added in the solution, the TiO2 passive film was destroyed and Na2TiF6 was formed.SignificanceAddition of Ag was found to be effective in reducing the corrosion current density and increasing the open circuit potential of titanium in artificial saliva environment. Addition of fluoride ions in the solution severely reduced the corrosion resistance of Ti–Ag alloys.  相似文献   

10.
ObjectiveThe aim of this study was to examine in vivo the initial bacterial adhesion on titanium implants with different surface treatments.DesignTen subjects wore oral splints containing machined pure titanium disks (Ti-M), acid-etched titanium (Ti-AE) and anodized and laser irradiated disks (Ti-AL) for 24 h. After this period, disks were removed from the splints and adherent bacteria were quantified by an enzymatic assay to assess total viable bacteria and by Real Time PCR to evaluate total bacteria and Streptococcus oralis levels. Additionally, the initial adherent microorganisms were visualized by scanning electron microscopy (SEM). Titanium surface morphology was verified using SEM, and roughness was evaluated by profilometer analysis.ResultsRegarding titanium surface roughness, Ti-AL (1.423 ± 0.397) showed significantly higher Ra values than did Ti-M (0.771 ± 0.182) and Ti-AE (0.735 ± 0.196) (p < 0.05, ANOVA – Tahame). Ti-AE and Ti-AL presented roughened micro-structure surfaces characterized by open pores, whereas Ti-M showed long grooves alternating with planed areas. Comparing the Ti-M, Ti-AE and Ti-AL groups for viable bacteria (MTT assay), total bacteria and S. oralis quantification (qPCR), no significant differences were observed among these three groups (p > 0.05, ANOVA – Tahame). SEM images showed similar bacterial adhesion on the three titanium surfaces, predominantly characterized by cocci and several bacilli, indicating an initial colonization of the oral biofilm.ConclusionIn conclusion, roughness and microtopography did not stimulate initial biofilm formation on titanium surfaces with different surface treatments.  相似文献   

11.
ObjectiveThe aim of the study was to evaluate the effects of the combined use of dentin matrix protein-1 (DMP1) gene-modified bone marrow stromal cells (BMSCs) and Bio-Oss® for maxillary sinus floor augmentation (MSFA) implant placement in dogs.Materials and methodsBMSCs were derived from bone marrow of six beagles and cultured. The cells were transduced with a lentiviral vector overexpressing the DMP1 gene and enhanced green fluorescent protein (EGFP) gene (Lenti-DMP1/EGFP) in test group, and with a lentiviral vector encoding EGFP gene (Lenti-EGFP) in control group. Six dogs received sinus augmentations using the bilateral approach with a simultaneous implant placement at each site respectively. At the same concentration, 2 × 107 cells/ml, one sinus was grafted using a mixture of autologous DMP1/EGFP gene-modified BMSCs and Bio-Oss® (DMP1 group), and the contralateral sinus was grafted with autologous EGFP gene-modified bMSCs and Bio-Oss® (EGFP group). After a 3 month healing period, bone regeneration and osseointegration were evaluated using histologic and histomorphometric methods.ResultsThe bone-implant contact (BIC) and the bone area fraction in the DMP1 group (BIC: 34.67% ± 8.23%, bone area fraction: 35.16% ± 3.32%) were significantly greater compared with the EGFP group (BIC: 26.06% ± 5.16%, bone area fraction: 20.74% ± 1.63%) (P < 0.05). No significant difference between the residual bone substitute material volume (BSMV) in the DMP1 group (35.86 ± 7.35) and the EGFP group (32.16 ± 9.16) was found in our study (P > 0.05).ConclusionBMSCs modified with the DMP1 gene can be used as an adjunct to Bio-Oss® to enhance new bone formation and the osseointegration of dental implants in MSFA of dogs.  相似文献   

12.
AimTo characterize microstructure, hardness and thermal properties of experimental Ag-based soldering alloys for dental applications.Materials and methodsAg12Ga (AgGa) and Ag10Ga5Sn (AgGaSn) were fabricated by induction melting. Six samples were prepared for each alloy and microstructure, hardness and their melting range were determined by, scanning electron microscopy, energy dispersive X-ray (EDX) microanalysis, X-ray diffraction (XRD), Vickers hardness testing and differential scanning calorimetry (DSC).ResultsBoth alloys demonstrated a gross dendritic microstructure while according to XRD results both materials consisted predominately of a Ag-rich face centered cubic phase The hardness of AgGa (61 ± 2) was statistically lower than that of AgGaSn (84 ± 2) while the alloys tested showed similar melting range of 627–762 °C for AgGa and 631–756 °C for AgGaSn.ConclusionThe experimental alloys tested demonstrated similar microstructures and melting ranges. Ga and Sn might be used as alternative to Cu and Zn to modify the selected properties of Ag based soldering alloys.  相似文献   

13.
ObjectiveThe present in situ - investigation aimed to specify the impact of pure hydroxyapatite microclusters on initial bioadhesion and bacterial colonization at the tooth surface.DesignPellicle formation was carried out in situ on bovine enamel slabs (9 subjects). After 1 min of pellicle formation rinses with 8 ml of hydroxyapatite (HA) microclusters (5%) in bidestilled water or chlorhexidine 0.2% were performed. As negative control no rinse was adopted. In situ biofilm formation was promoted by the intraoral slab exposure for 8 h overnight. Afterwards initial bacterial adhesion was quantified by DAPI staining and bacterial viability was determined in vivo/in vitro by live/dead-staining (BacLight). SEM analysis evaluated the efficacy of the mouthrinse to accumulate hydroxyapatite microclusters at the specimens’ surface and spit-out samples of the testsolution were investigated by TEM.ResultsCompared to the control (2.36 × 106 ± 2.01 × 106 bacteria/cm2), significantly reduced amounts of adherent bacteria were detected on specimens rinsed with chlorhexidine 0.2% (8.73 × 104 ± 1.37 × 105 bacteria/cm2) and likewise after rinses with the hydroxyapatite testsolution (2.08 × 105 ± 2.85 × 105 bacteria/cm2, p < 0.001). No demonstrable effect of HA-particles on Streptococcus mutans viability could be shown. SEM analysis confirmed the temporary adsorption of hydroxyapatite microclusters at the tooth surface. Adhesive interactions of HA-particles with oral bacteria were shown by TEM.ConclusionHydroxyapatite microclusters reduced initial bacterial adhesion to enamel in situ considerably and could therefore sensibly supplement current approaches in dental prophylaxis.  相似文献   

14.
ObjectiveThis study investigated the anti-demineralizing and antibacterial effects of a propolis ethanolic extract (EEP) against Streptococcus mutans dental biofilm.DesignBlocks of sound bovine enamel (n = 24) were fixed on polystyrene plates. S. mutans inoculum (ATCC 25175) and culture media were added (48 h–37 °C) to form biofilm. Blocks with biofilm received daily treatment (30 μL/1 min), for 5 days, as following: G1 (EEP 33.3%); G2 (chlorhexidine digluconate 0.12%); G3 (ethanol 80%); and G4 (Milli-Q water). G5 and G6 were blocks without biofilm that received only EEP and Milli-Q water, respectively. Final surface hardness was evaluated and the percentage of hardness loss (%HL) was calculated. The EEP extract pH and total solids were determined. S. mutans count was expressed by log10 scale of Colony-Forming Units (CFU/mL). One way ANOVA was used to compare results which differed at a 95% significance level.ResultsG2 presented the lowest average %HL value (68.44% ± 12.98) (p = 0.010), while G4 presented the highest (90.49% ± 5.38%HL) (p = 0.007). G1 showed %HL (84.41% ± 2.77) similar to G3 (87.80% ± 6.89) (p = 0.477). Groups G5 and G6 presented %HL = 16.11% ± 7.92 and 20.55% ± 10.65; respectively (p = 0.952). G1 and G4 differed as regards to S. mutans count: 7.26 ± 0.08 and 8.29 ± 0.17 CFU/mL, respectively (p = 0.001). The lowest bacterial count was observed in chlorhexidine group (G2 = 6.79 ± 0.10 CFU/mL) (p = 0.043). There was no difference between S. mutans count of G3 and G4 (p = 0.435). The EEP showed pH 4.8 and total soluble solids content = 25.9 Brix.ConclusionThe EEP seems to be a potent antibacterial substance against S. mutans dental biofilm, but presented no inhibitory action on the de-remineralization of caries process.  相似文献   

15.
ObjectivesThis study evaluated the effect of thermal- and mechanical-cycling on the shear bond strength of three low-fusing glassy matrix dental ceramics to commercial pure titanium (cpTi) when compared to conventional feldspathic ceramic fused to gold alloy.MethodsMetallic frameworks (diameter: 5 mm, thickness: 4 mm) (N = 96, n = 12 per group) were cast in cpTi and gold alloy, airborne particle abraded with 150 μm aluminum oxide. Low-fusing glassy matrix ceramics and a conventional feldspathic ceramic were fired onto the alloys (thickness: 4 mm). Four experimental groups were formed; Gr1 (control group): Vita Omega 900–Au–Pd alloy; Gr2: Triceram–cpTi; Gr3: Super Porcelain Ti-22–cpTi and G4: Vita Titankeramik–cpTi. While half of the specimens from each ceramic–metal combination were randomly tested without aging (water storage at 37 °C for 24 h only), the other half were first thermocycled (6000 cycles, between 5 and 55 °C, dwell time: 13 s) and then mechanically loaded (20,000 cycles under 50 N load, immersion in distilled water at 37 °C). The ceramic–alloy interfaces were loaded under shear in a universal test machine (crosshead speed: 0.5 mm/min) until failure occurred. Failure types were noted and the interfaces of the representative fractured specimens from each group were examined with stereomicroscope and scanning electron microscope (SEM). In an additional study (N = 16, n = 2 per group), energy dispersive X-ray spectroscopy (EDS) analysis was performed from ceramic–alloy interfaces. Data were analyzed using ANOVA and Tukey's test.ResultsBoth ceramic–metal combinations (p < 0.001) and aging conditions (p < 0.001) significantly affected the mean bond strength values. Thermal- and mechanical-cycling decreased the bond strength (MPa) results significantly for Gr3 (33.4 ± 4.2) and Gr4 (32.1 ± 4.8) when compared to the non-aged groups (42.9 ± 8.9, 42.4 ± 5.2, respectively). Gr1 was not affected significantly from aging conditions (61.3 ± 8.4 for control, 60.7 ± 13.7 after aging) (p > 0.05). Stereomicroscope images showed exclusively adhesive failure types at the opaque ceramic–cpTi interfacial zone with no presence of ceramic on the substrate surface but with a visible dark titanium oxide layer in Groups 2–4 except Gr1 where remnants of bonder ceramic was visible. EDS analysis from the interfacial zone for cpTi–ceramic groups showed predominantly 34.5–85.1% O2 followed by 1.1–36.7% Al and 0–36.3% Si except for Super Porcelain Ti-22 where a small quantity of Ba (1.4–8.3%), S (0.7%) and Sn (35.3%) was found. In the Au–Pd alloy–ceramic interface, 56.4–69.9% O2 followed by 15.6–26.2% Si, 3.9–10.9% K, 2.8–6% Na, 4.4–9.6% Al and 0–0.04% Mg was observed.SignificanceAfter thermal-cycling for 6000 times and mechanical-cycling for 20,000 times, Triceram–cpTi combination presented the least decrease among other ceramic–alloy combinations when compared to the mean bond strength results with Au–Pd alloy–Vita Omega 900 combination.  相似文献   

16.
ObjectiveThe objective of this study was to clarify the influence of chromium content on surface reaction of Ti–Cr alloys in an acidic fluoride-containing saline solution.MethodsFour Ti–Cr alloys containing 5, 10, 15 or 20 mass% chromium were characterized in terms of dissolution of metals in an acidic fluoride-containing saline solution and surface structure by X-ray photoelectron spectroscopy and Auger electron spectroscopy.ResultsTotal amount of metals dissolved from each alloy decreased with increase in chromium content. The surface oxide films of Ti–Cr alloys before and after immersion in an acidic fluoride-containing saline solution consisted of titanic and chromic species, such as oxide, hydroxide, and hydrate. The [Cr]/([Ti] + [Cr]) ratio in the surface oxide film on as-polished Ti–Cr alloys was closely correlated with chromium content. However, the ratio in any alloy approximately doubled after immersion. Although thick oxide films were observed after immersion, all alloys showed a thinner oxide film than commercially pure titanium.SignificantIn all alloys, concentration of chromic species such as oxide and hydroxide in the surface oxide film was associated with chromium content, and chromic species improved corrosion resistance to fluoride.  相似文献   

17.
PurposeTo determine the effect of material type and restoration thickness on the fracture strength of posterior occlusal veneers made from computer-milled composite (Paradigm MZ100) and composite-ceramic (Lava Ultimate) materials.Methods60 maxillary molars were prepared and restored with CAD/CAM occlusal veneer restorations fabricated from either Paradigm MZ100 or Lava Ultimate blocks at minimal occlusal thicknesses of 0.3, 0.6, and 1.0 mm. Restorations were adhesively bonded and subjected to vertical compressive loading. The maximum force at fracture and mode of failure were recorded. 2-Way ANOVA was used to identify any statistically significant relationships between fracture strength and material type or thickness. Spearman's rank correlation coefficient was used to analyze mode of failure with regard to fracture strength.ResultsThe average maximum loads (N) at fracture for the Paradigm MZ100 groups were 1620 ± 433, 1830 ± 501, and 2027 ± 704 for the material thicknesses of 0.3, 0.6, and 1.0 mm, respectively. The Lava Ultimate groups fractured at slightly higher loads (N) of 2078 ± 605, 2141 ± 473, and 2115 ± 462 at the respective 0.3, 0.6, and 1.0 mm thickness.Statistical analyses revealed that, while no significant difference existed among the various restoration thicknesses in terms of fracture strength (P > 0.05), the material type was found to be influential (P = 0.04). The maximum load at fracture (N) for Lava Ultimate averaged over all thicknesses (2111 ± 500) was significantly higher than that of the Paradigm MZ100 (1826 ± 564). No correlation between mode of failure and fracture strength was found.ConclusionsUnder the conditions of this study, the maximal loads at fracture for these “non-ceramic” occlusal veneer restorations were found to be higher than human masticatory forces. Occlusal veneers made from the two materials tested are likely to survive occlusal forces regardless of restoration thickness, with those fabricated from the composite-ceramic hybrid material being more likely to survive heavier loads.  相似文献   

18.
ObjectiveElemental release is important because it plays a significant role in material biocompatibility. The aim of this study was to investigate the release of metal ions from four fixed prosthodontic materials.MethodsSpecimens were prepared using the conventional lost wax technique for gold and nickel–chromium (Ni–Cr) alloys, and by cutting blocks and bar for CAD–CAM ceramic and stainless-steel (St-St) alloy, respectively. All specimens were polished (600 grit SiC paper), and ultrasonically cleaned with ethanol for 5 min. After they were immersed in 0.9% sodium chloride (NaCl) and 1% lactic acid, and were kept at 37 °C for 7 days, the elemental release (μg/cm2) from each material was analyzed by using inductively coupled plasma mass spectroscopy. The rate (n = 5) was statistically analyzed by ANOVA/Tukey test (p < 0.05). Two immersion blank solutions were used as a negative control group.ResultsHigher elemental release (mean ± S.D.) of all elements from all materials was evident into the lactic acid solution except for Ag. In the gold alloy, there was significant difference (p < 0.05) between Zn and other released elements in the NaCl solution, and it also revealed significant difference between Pd or Ag and Cu which detection value was more than Zn (but no statistical difference) into lactic acid solution. The Ni was significantly more released from Ni–Cr alloy than the other elements into both NaCl and lactic acid solutions. The same was observed for Fe released from St-St alloy. There was more significant release of K than Al from CAD–CAM ceramic in only NaCl solution.SignificanceTransient exposure of tested materials to an acidic environment is likely to significantly increase the elemental release from them. The significant higher release of Ni from Ni–Cr alloy, and Zn, Cu from gold alloy was evident.  相似文献   

19.
ObjectivePhosphoryl oligosaccharides of calcium (POs-Ca) are highly soluble calcium source made from potato starch. The aim of this study was to investigate the optimal concentrations of POs-Ca for the remineralization of subsurface enamel lesions in vitro.DesignDemineralized bovine enamel slabs (n = 5) were remineralized in vitro for 24 h at 37 °C with artificial saliva (AS) containing 0–0.74% POs-Ca to adjust the Ca/P ratio to 0.4–3.0, then sectioned and analysed by transversal microradiography (TMR). The data were analysed by Scheffe's post hoc test. The Ca/P ratio with most remineralization was used to investigate the effect of calcium on enamel remineralization (n = 11). The demineralized slabs were treated with AS with calcium-chloride- (CaCl2-) or POs-Ca with an identical calcium content, and sectioned for TMR and wide-angle X-ray diffraction (WAXRD) analyses to evaluate the local changes in hydroxyapatite (HAp) crystal content. The data were analysed using the Mann–Whitney U-test.ResultsThe highest mineral recovery rate resulted from addition of POs-Ca to adjust the Ca/P to 1.67. At this ratio, the mineral recovery rate for AS containing POs-Ca (24.2 ± 7.4%) was significantly higher than that for AS containing CaCl2 (12.5 ± 11.3%) (mean ± SD, p < 0.05). The recovery rate of HAp crystallites for AS containing POs-Ca (35.7 ± 10.9%) was also significantly higher than that for AS containing CaCl2 (23.1 ± 13.5%) (p < 0.05). The restored crystallites were oriented in the same directions as in sound enamel.ConclusionsPOs-Ca effectively enhances enamel remineralization with ordered HAp at a Ca/P ratio of 1.67.  相似文献   

20.
PurposeThe present study aimed to evaluate the retention and stress distribution of conventional (C) RPD and compare to RPD associated to implant for support (IS) and retention (IR).MethodsFrameworks were cast from cp Ti (n = 18) and Co–Cr alloy (n = 18) by plasma and injected by vacuum–pressure. Conventional RPDs were compared to implant associated RPDs using a distal implant to support (IS) or to support and retain (IR) RPD. The specimens were subjected to insertion/removal cycles simulating 5 years of use and the retention force (N) was measured or evaluated. A mixed linear model was used to analyze the data (α = 0.05). Photoelastic models were qualitatively examined for stress when an occlusal load of 15 kgf was applied over support teeth and RPD.ResultsRetention force of IR RPDs is greater than IS and C RPDs for both cp Ti and Co–Cr alloy specimens. Retention force of cp Ti RPDs increased initially and was maintained throughout 5 years of simulation test while Co–Cr RPDs presented a decrease at the beginning of the test and had their retention force maintained throughout the test. Implant placement at residual alveolar ridge decreased stress around teeth, mainly in the first premolar. Stress concentration in the IS RPD is slightly greater than in the IR RPD.ConclusionThe results suggest that implant placement at the distal extension improves retention and stress distribution of RPDs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号