首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
交锁钉与加压钢板固定尺骨骨折的生物力学比较   总被引:1,自引:0,他引:1  
[目的] 对交锁髓内钉与动力加压钢板固定尺骨骨折的生物力学性能进行测试,为临床应用提供理论依据.[方法] 采用12根新鲜尺骨标本,制作成中段横形骨折模型,分别用交锁髓内钉和6孔3.5 mm动力加压钢板固定,髓内钉规格为φ4mm,长200~230 mm.将标本固定于MTS试验机,对其进行抗轴向压缩、抗弯曲、抗扭转的生物力学测试,比较分析抗压刚度、抗弯刚度、抗扭刚度和抗压强度、抗弯强度、抗扭强度.[结果]交锁髓内钉固定的抗轴向压缩刚度、抗弯曲刚度和抗扭转刚度依次为(450.00±38.42)N/mm、(45.64±5.24)N·cm/Deg、(11.42±1.21)N·cm/Deg;6孔3.5mm动力加压钢板固定的抗轴向压缩刚度、抗弯曲刚度和抗扭转刚度分别为(405.40 4-29.26)N/mm、(41.00±4.78)N·cm/Deg、(10.05±1.32)N·cm/Deg.在1000 N轴向压缩载荷作用下,交锁髓内钉和加压钢板固定时尺骨的位移分别为(2.20±0.11)mm和(2.48±0.15)mm;在5 N·m弯曲载荷下,采用交锁髓内钉固定的尺骨的最大桡度为(3.25±0.15)mm,加压钢板固定的最大桡度为(3.60±0.21)mm;在扭转试验中,交锁髓内钉固定能承受扭矩最大达(2.40±0.13)N·m,而加压钢板固定能承受的扭矩为(1.90±0.10)N·m;实验所得的数据采用SPSS.10软件处理,再进行t检验显示具有显著性差异(P<0.05).可见交锁髓内钉在力学刚度和强度上均优于6孔3.5mm动力加压钢板固定.[结论] 交锁髓内钉具有良好的生物力学性能,固定可靠,符合生物学固定的原则.  相似文献   

2.
目的:评价经皮长尾可折U形空心椎弓根钉系统内固定治疗胸腰椎骨折的临床疗效。方法:选择2009年1月~2010年8月无明显神经损伤的不稳定胸腰椎骨折患者80例,分A组(长尾可折U形空心椎弓根钉系统内固定),B组(常规开放椎弓根钉固定),比较两组的手术切口长度、手术时间、术中出血量、术后切口引流量以及手术前后伤椎椎弓前缘高度、矢状面Cobb角、椎管骨块占位率、置钉优良率以及术后3、6、12个月随访比较椎体高度、Cobb角及腰痛情况等。结果:两组手术时间、术中出血量、术后切口渗血及切口总长度A组分别为90.18±17.39min、81.25±8.67ml、6.60±1.64ml及6.86±0.60cm;B组分别为116.95±16.18min、315.70±72ml、224.48±30.18ml及13.53±1.48cm。以上各指标A、B两组有明显差异(P<0.05)。术后椎体前缘高度、Cobbs角、椎管骨块占位率及置钉优良率A组分别为(93.83±4.20)%、4.28°±1.08°、(3.49±3.27)%及96.25%;B组分别为(94.31±3.12)%、3.95°±0.97°、(3.27±3.03)%及97.50%,以上指标两组比较差异没有显著性(P>0.05);术后3、6、12个月随访影像学指征两组间无显著差异(P>0.05)。结论:经皮长尾可折U形空心椎弓根钉具有创伤小、操作方便、复位固定及效果与常规椎弓根钉固定一致,值得临床推广应用。  相似文献   

3.
目的探讨微创空心椎弓根钉加骨水泥强化治疗骨质疏松性胸腰椎骨折的近期疗效。方法应用可灌注骨水泥长U形空心椎弓根钉固定骨水泥强化治疗骨质疏松性胸腰椎骨折60例。结果所有患者均顺利完成手术,手术切口长度(3.76±1.14)cm,手术时间(91.78±8.34)min,术中出血量(68.78±10.76)ml,60例在术后1 d、术后6个月的伤椎椎体前缘高度、Cobb角、椎体压缩程度、椎管骨块占位率与术前比较,差异有统计学意义(P0.05),术后1 d与术后6个月比较则差异无统计学意义(P0.05)。结论微创空心椎弓根钉加骨水泥强化治疗骨质疏松性胸腰椎骨折具有创伤小、手术时间短、术中出血少、术后并发症少等优点。  相似文献   

4.
目的对人体标本胸椎弓根壁破裂3种补救置钉方法进行生物力学对比。方法选取5具青壮年尸体共30个胸椎体60个椎弓根,分为强化空心钉(HSS)组(15个椎弓根)、皮质骨通道螺钉(CBTS)组(30个椎弓根)和椎弓根-肋骨单元钉(PRUS)组(15个椎弓根),制成椎弓根内侧壁破裂模型。完成置钉后分别进行螺钉轴向抗拔出力实验,比较最大轴向抗拔出力、刚度、能量吸收值。结果 HSS组、CBTS组、PRUS组螺钉最大轴向抗拔出力分别为(973. 00±23. 88) N、(647. 13±21. 89) N、(613. 00±23. 25) N,差异有统计学意义(P 0. 05)。HSS组、CBTS组、PRUS组刚度分别为(284. 61±14. 77) N/mm、(218. 82±11. 84) N/mm、(194. 72±13. 06) N/mm,差异有统计学意义(P 0. 05)。HSS组、CBTS组、PRUS组能量吸收值分别为(2. 77±0. 13) J、(1. 41±0. 40) J、(1. 31±0. 57) J,HSS组与CBTS组、PRUS组比较差异有统计学意义(P 0. 05),但CBTS组与PRUS组比较差异无统计学意义(P 0. 05)。结论在胸椎弓根壁破裂情况下,HSS、CBTS、PRUS 3种补救置钉均能够提供内固定稳定,HSS内固定稳定性最大,CBTS次之,PRUS最小。  相似文献   

5.
目的通过与开放椎弓根钉内固定手术相比较,探讨经皮微创普通椎弓根钉内固定辅助系统治疗胸腰椎骨折的临床效果。方法自2008年1月至2012年12月将86例胸腰椎骨折随机分为两组(n=43),分别采用经皮普通椎弓根钉内固定(微创组)和开放椎弓根钉内固定(开放组)治疗胸腰椎骨折,比较两组伤椎前缘高度比值、矢状面Cobb角、手术时间、出血量及并发症等情况。结果术后所有患者随访6~48个月,平均18.6个月。微创组伤椎前缘高度比值平均从术前(47.5±8.6)%恢复至术后(90.3±5.8)%,Cobb角平均从术前(17.6±6.20)°恢复至术后(2.0±1.30)°,微创组术后伤椎前缘高度比值与开放组(91.7±5.0)%相比较差异无统计学意义(P0.05),微创组术后伤椎矢状面Cobb角与开放组(1.9±1.20)°相比较差异无统计学意义(P0.05),微创组手术时间平均(94.0±21.3)min,与切开组(98.5±16.5)min比较差异无统计学意义(P0.05)。微创组术中出血量平均(54.4±12.6)mL,与切开组(289.1±20.5)mL比较差异有统计学意义(P0.05)。除开放组1例出现切口感染外,两组未出现其他手术相关并发症。结论经皮普通椎弓根钉内固定辅助系统治疗胸腰椎骨折与开放性椎弓根钉内固定手术相比创伤小,出血少,患者恢复快,可达到开放复位同样的疗效。  相似文献   

6.
目的 探讨带有MBP中空侧孔新型椎弓根钉的作用特点,明确其在腰椎骨折模型中内固定的效果.方法 比较两种不同椎弓根钉的生物力学测试,包括轴向最大拔出力,垂直压缩刚度及极限压缩强度.采用X线摄片及CT观察伤椎内固定后的大体形态,比较两组中伤椎前缘高度及椎管正中矢状径(MD)的差异.结果 新型椎弓根钉组其平均轴向最大拔出力明显高于普通型组,差异有统计学意义(P<0.05);两种椎弓根钉行椎弓根钉固定后即刻状态的整体刚度差异无统计学意义(P>0.05),极限抗压强度差异有统计学意义(P<0.05).普通型与新型椎弓根钉相比较,其平均前缘高度及伤椎平均MD值差异均有统计学意义(P<0.05).结论 新型椎弓根钉内固定的稳定性明显优于普通型椎弓根钉,值得推广应用.  相似文献   

7.
肱骨干骨折髓内外固定的生物力学研究   总被引:2,自引:0,他引:2  
目的 通过对单一加压钢板螺钉加髓内针、交锁髓内钉和微创技术简单有限内固定加单臂外支架3种不同固定方法治疗肱骨干复杂骨折的生物力学性能进行对比研究,为临床应用提供可靠的生物力学依据.方法 取自愿捐赠的18个新鲜湿润肱骨标本,制备肱骨干复杂骨折模型,根据不同固定方式随机分为3组,每组6个.钢板组:采用单一加压钢板螺钉加髓内针固定;髓内钉组:采用交锁髓内钉固定;外支架组:采用微创技术简单有限内固定加单臂外支架固定.分别进行轴向压缩实验和水平扭转实验.结果 轴向压缩实验:各组载荷-位移曲线呈线性到非线性变化.钢板组及髓内钉组最大载荷值分别为(6162.09±521.06)N和(6738.32±525.89)N,两组比较差异无统计学意义(P>0.05);外支架组最大载荷值为(2753.57±185.59)N,与其余两组比较,差异均有统计学意义(P<0.05).钢板组及外支架组刚度值分别为(171.69±6.49)N/mm和(132.59±2.93)N/mm,两组比较差异无统计学意义(P>0.05);髓内钉组的刚度值为(333.04±36.85)N/mm,与其余两组比较差异有统计学意义(P<0.05).水平扭转实验:各组扭矩-扭角曲线呈线性到非线性变化.髓内钉组和外支架组的最大扭矩分别为(17.12±5.73)Nm和(20.26±6.42)Nm,两组比较差异无统计学意义(P>0.05);钢板组的最大扭矩为(38.24±7.08)Nm,与其余两组比较差异有统计学意义(P<0.05).钢板组及外支架组刚度值分别为(16.36±2.07)Ncm/°和(18.79±2.62)Ncm/°,差异无统计学意义(P>0.05);髓内钉组的刚度值为(11.45±0.22)Ncm/°,与其余两组比较差异有统计学意义(P<0.05).结论 钢板组压缩和扭转强度均较强,旋转刚度较强而压缩刚度较弱;髓内钉组压缩强度和压缩刚度较强,而扭转强度和扭转刚度较弱;外支架组仅在扭转刚度上与钢板组相当,而在其他3项指标上均较弱.  相似文献   

8.
目的比较经皮椎体成形术(PVP)和椎弓根螺钉内固定(PSF)治疗骨质疏松性胸腰椎骨折的生物力学强度,为临床应用和离床活动指导提供实验依据。方法18具冻存的新鲜尸体,应用双能X线骨密度仪(DEXA)测定脊柱的骨密度(BND),取胸腰段脊椎(T_(12)~L_2 12具,L_1 6具)随机分成三组:PVP组、PSF组(T_(12)L_2)和正常对照组(L_1),每组6具。PVP组和PFS组实验椎体均制成骨折模型,PVP组给予经双侧椎弓根注入低粘度的含显影剂骨水泥各2.5mL。PSF组于T_(12)、L_2椎弓根置入钉棒系统固定,测试并比较两组和对照组静态最大抗压强度及刚度。结果PVP组骨水泥分布面积皆大于50%,其平均最大抗压强度与刚度分别为(2645±478)N,(117±81)N/mm;PSF组平均最大抗压强度与刚度分别为(1862±620)N,(125±33)N/mm。两组比较平均最大抗压强度差异有显著性意义(P<0.05),最大刚度差异无显著性意义(P>0.05)。结论骨折椎体内注入骨水泥PMMA,其抗压强度优于椎弓根钉方法,对于轻度骨质疏松者尤为适用。PVP术后患者可早期(3~5d)下床活动,而PSF术后患者离床活动时间可适当延后。  相似文献   

9.
[目的]探讨一种新型钉道强化椎弓根螺钉在骨质疏松椎体中的生物力学特性。[方法]从4具老年尸体中选取20个腰椎标本(L_(1~5)),均符合骨质疏松症诊断标准(T-2.5),采用随机分4组,每组5个椎体。分别为单纯普通椎弓根螺钉组(无强化组)、普通椎弓根螺钉强化组(普通强化组)、可注射空心椎弓根螺钉强化组(空心钉强化组)、新型钉道强化椎弓根螺钉强化组(新型强化组)。观察骨水泥分布情况,并测量各组螺钉最大轴向拔出力及不同螺钉的刚度。[结果]三种强化骨水泥的分布不同,普通强化组骨水泥主要分布于椎体前部;空心钉强化组骨水泥主要分布于椎体前部及部分中后部,新型强化组骨水泥主要分布于钉道周围,包括椎体前、中、后部及部分椎弓根部。生物力学测量最大轴向拔出力依次为:新型强化组空心钉强化组普通强化组无强化组,差异具有统计学意义(P0.05)。螺钉刚度依次为普通螺钉新型螺钉空心螺钉,差异有统计学意义(P0.05)。[结论]新型钉道强化椎弓根螺钉能够提高螺钉在骨质疏松椎体固定的稳定性,且骨水泥分布有所改善,螺钉的刚度适中。  相似文献   

10.
[目的]通过生物力学测试对胸腰椎爆裂性骨折伤椎单侧短椎弓根钉固定的稳定性及刚度进行评价.[方法]取18具新鲜小牛胸腰段(T11 ~L3)标本,制作成胸腰椎爆裂性骨折模型,测试跨节段4枚椎弓根钉固定(4钉组)、伤椎单侧短椎弓根钉固定(5钉组)、伤椎双侧椎弓根钉固定(6钉组)标本模型的轴向压缩刚度及三维6个方向的运动范围(ROM).[结果]4钉组、5钉组、6钉组三种固定方式,均能提高骨折模型的稳定性及刚度;5钉组、6钉组模型刚度均明显高于4钉组,差异有统计学意义(P<0.05),5钉组、6钉组模型在屈伸、侧弯、旋转6个方向的运动范围(ROM)均明显低于4钉组,差异有统计学意义(P<0.05);而5钉组与6钉组模型之间的刚度比较差异无统计学意义(P>0.05),5钉组与6钉组模型在屈伸、侧弯、旋转6个方向的运动范围(ROM)的比较差异无统计学意义(P>0.05).[结论]对于胸腰椎爆裂性骨折,伤椎置钉固定能明显提高脊柱的刚度及稳定性,经伤椎单侧短椎弓根钉固定与伤椎双侧椎弓根钉固定对脊柱刚度及稳定性的影响无明显差异.  相似文献   

11.
We used a computer to assess the degrees and types of the vertebral deformity on simple lateral X-ray pictures of thoracic and lumbar vertebrae. We studied X-ray pictures of 120 females who were diagnosed as having postmenopausal or senile osteoporosis. The vertebral deformities were classified into five types; N: normal; I: vertex vertebra; II: fish vertebra; III: vertebra plana; IV: reverse vertex vertebra. Also, visual assessment of X-ray pictures was carried out by physicians. 3,018 of a total of 3,419 vertebral bodies were judged as normal (N) by physicians. 2,904 of these 3,018 vertebral bodies were judged normal (N) by our computer method. The rate of conformity was 96.22%. For vertex vertebra (I), fish vertebra (II) and vertebra plana (III), the rate of conformity the was 84.64%, 90.48% and 60.56% respectively. As a judgement of the presence/absence of the vertebral deformity, the computer method indicated that 114 of 3,018 vertebral bodies judged to be normal (N) by physicians were more or less deformed.  相似文献   

12.
颈腰椎椎板厚度测量及意义   总被引:5,自引:0,他引:5  
目的:为确定颈腰椎椎板厚度及其与谁管矢状径的关系。方法:对85套腰椎和66套颈椎的椎板厚度以及椎管矢状径进行测量统计,并做相关性分析。结果:C_4椎权最薄.C_7最厚;腰椎椎板厚反以L_3最厚,L_4最薄;左右侧椎板厚度无显著性差异.椎板厚度与矢状径的相关性分析.P>0.05。结论:椎板厚及与椎管矢状径无关。  相似文献   

13.
目的:探讨休门氏病后凸畸形的下端椎(lower end vertebra,LEV)、首个前凸椎(first lordotic vertebra,FLV)与矢状面稳定椎(sagittal stable vertebra,SSV)的相互关系。方法:2003年1月~2008年12月收治休门氏病胸椎或胸腰椎后凸畸形患者26例,男17例,女9例;年龄14~53岁,平均22.1岁;胸椎后凸17例,胸腰椎后凸9例。在站立位全脊柱侧位X线片上测量LEV、FLV和SSV。根据测量结果,统计分析LEV、FLV和SSV之间的相互关系。结果:17例胸椎后凸中,LEV=FLV3例,LEV=FLV-112例,LEV=FLV-22例;FLV=SSV6例,FLV=SSV-18例,FLV=SSV-23例;LEV=SSV1例,LEV=SSV-14例,LEV=SSV-211例,LEV=SSV-31例。9例胸腰椎后凸中,LEV=FLV3例,LEV=FLV-16例;FLV=SSV3例,FLV=SSV-16例;LEV=SSV-16例,LEV=SSV-23例。结论:休门氏病胸椎或胸腰椎后凸畸形患者远端融合水平延至SSV与固定到FLV相比,绝大多数情况下并不增加融合节段或仅增加1个节段。  相似文献   

14.
侧前方病灶清除人工椎体置换术治疗胸椎结核后凸畸形   总被引:1,自引:1,他引:0  
目的:探讨脊柱侧前方病灶清除椎间轴套式钛合金人工椎体置换治疗胸椎结核并后凸畸形的疗效。方法:胸椎结核并后凸畸形患者19例,后凸Cobb角15°~30°,平均25°,7例患者合并脊髓压迫,Frankel分级C级3例,D级4例。手术方法为一期侧前方病灶清除椎间轴套式钛合金人工椎体置换,置换的人工椎体内置入松质骨。术后抗结核药物治疗9个月。结果:随访2~3年,平均2年4个月。切口均一期愈合,椎体无滑脱,胸椎结核全部治愈,脊髓功能损害者术后1年内完全恢复。术后后凸Cobb角平均8°,平均矫正17°,随访期间畸形矫正无明显丢失。结论:胸椎结核侧前方病灶清除人工椎体置换术治疗胸椎结核并后凸畸形效果较好,能够一期完成病灶清除、脊髓减压、脊柱稳定性重建和后凸畸形矫正。  相似文献   

15.
胸腰椎结核的前路手术治疗探讨   总被引:3,自引:1,他引:2  
[目的]探讨一期前路病灶清除植骨内固定治疗胸腰椎结核的可行性及临床疗效。[方法]自1999年7月~2006年7月对37例胸腰椎结核患者进行一期前路病灶清除植骨内固定。男性21例,女性16例;年龄21~67岁,平均39.6岁。病变节段:T4~1010例;T11~L111例;L3~516例。术前融合节段后凸角(21.5±4.5)°,20例存在脊髓压迫,FrankelB级4例,C级6例,D级10例。术前静脉强化抗痨治疗1~2周,术中根据相应节段选择不同治疗方法,术中彻底清除病灶,21例采用钛网植骨,16例单独应用肋骨或三面皮质髂骨植骨后行前路内固定。术后根据药敏做规则抗痨治疗1年。[结果]全部病例随访0.5~3.5年,平均1.5年,除1例术后第2d死亡,切口均甲级愈合。术后3个月ESR均正常,术后融合节段后凸角为(7.2±3.5)°,终末随访时钛网内固定组丢失(4.2±1.6)°,单纯植骨组丢失,神经功能均有不同程度恢复。[结论]一期前路病灶清除植骨内固定治疗胸腰椎结核时要进行充分有效的药物抗痨治疗,术中清除病灶要彻底,遗留过多的椎间缺损可以通过钛网或人工椎体的植入来弥补单纯植骨的缺陷。  相似文献   

16.
AF复位固定结合椎体成形术治疗胸腰椎爆裂性骨折   总被引:5,自引:0,他引:5  
目的探讨AF椎弓根固定复位并椎体缺损空洞部位充填骨水泥,即刻获得骨折椎体前、中、后三柱稳定的方法治疗胸腰椎爆裂性骨折的疗效。方法对16例胸腰椎爆裂性骨折,采用短节段椎弓根AF系统复位内固定,根据临床神经症状和影像资料行椎管减压或不减压。复位后经后路向伤椎内骨缺损注射骨水泥充填缺损即刻获得骨折椎体前、中、后三柱稳定。术前及术后随访行X线检查,测量伤椎椎体高度变化和相邻间隙变化等。了解术后骨折复位情况以及随访期间内固定有无失败和复位丢失情况。结果16例均获随访,椎体高度恢复并维持良好,无塌陷、间隙无明显改变,术前神经症状消失。结论AF短节段复位固定、骨水泥充填伤椎骨缺损即刻获得骨折椎体前、中、后三柱稳定治疗胸腰椎爆裂性骨折不仅能有效地填充椎体内骨缺损,而且可早期下床活动,无椎体高度丢情况。  相似文献   

17.

Objective

The aim of this study was to investigate the effect of distal fusion level selection on the distal junctional kyphosis (DJK) in Scheuermann kyphosis (SK) patients who underwent posterior fusion.

Methods

Thirty-nine SK patients who underwent posterior fusion with a minimum follow-up of 3 years were retrospectively evaluated. According to the distal fusion level, patients were divided into 3 groups. Group S; lowest instrumented vertebra (LIV) was the sagittal stable vertebra (SSV), Group F; LIV was the first lordotic vertebra (FLV) and, Group L; LIV was the lower end vertebra (LEV). DJK was evaluated according to distal level selection.

Results

Thoracic kyphosis (TK) decreased from 73.3° (SD ± 7.9°) to 39° (SD ± 8.7°) postoperatively, with a mean correction rate of 46% (SD ± 13) (p < 0.0001). In 11 patients, FLV and SSV was the same vertebra. In remaining 28 patients, 10 patients were in Group S, 15 patients were in Group F and 3 patients were in Group L. In Group S, none of them developed DJK, however, DJK was observed 9 of 15 patients in Group F. DJK was developed in all cases in Group L. There is a statistically higher risk for developing DJK when FLV or LEV was selected as LIV (p < 0.05).

Conclusion

Selecting SSV for the distal fusion level has been found to be effective for preventing DJK. Selecting distal fusion level proximal to SSV will increase the risk of DJK which may become symptomatic and require revision surgery.

Level of evidence

Level IV, therapeutic study.  相似文献   

18.
合并腰椎疾患的下胸椎黄韧带骨化临床诊治   总被引:2,自引:2,他引:0  
目的探讨合并腰椎疾患的下胸椎黄韧带骨化临床特点及诊治方法。方法下胸椎黄韧带骨化同时存在腰椎疾患的患者23例,诊断结合X线、椎管造影、CT、MRI检查,体征以肌张力增高和深反射异常为特点;患者均采用病变节段全椎板减压手术治疗。结果23例均获随访,时间10-36个月,手术减压1-3节胸椎椎板,患者在末次随访时都有不同程度的神经功能改善。术后功能恢复优4例,良13例,可6例。术后到末次随访时无一例患者因腰椎疾病而再次接受手术。结论合并腰椎疾患的下胸椎黄韧带骨化需要注意将客观体征与多种影像学检查相结合,尽早诊断、早期手术。  相似文献   

19.
目的比较分析胸腰椎骨折在后路器械固定下对椎管间接减压与开放减压两种方式的临床疗效。方法回顾性分析2001年1月~2004年12月收治的76例胸腰椎骨折患者,将其分为两组:42例行后路暴露、椎弓根螺钉系统复位内固定术,将其定义为间接减压组;34例行半椎板或全椎板减压,椎弓根螺钉内固定,半椎板、横突或关节突融合术,定义为开放减压组。观察两组的术中情况及并发症,评价各组的脊柱矫形、椎管占位、复位及神经功能恢复情况,各组观察指标进行统计学比较分析。结果间接减压组的平均手术时间、术中出血量及术后引流量分别为65 min、150 mL和70 mL,而开放减压组为110min、360 mL和145 mL,两组间差异有显著性意义(P<0.05)。椎体前高、后高、Cobb角随访时的丢失率及丢失角度两组分别为:间接减压组为2.3%、1.2%和0.5°,开放减压组为7.7%、2.6%和3.1°,两组间差异无显著性意义(P>0.05)。间接减压组术后椎管平均减压30.2%,开放减压组32.2%。两组术后Frankel分级均有1~2级改善。结论间接减压组较开放减压组具有手术时间短、术中出血少、术后引流量少、脊柱矫正度丢失率低、术后康复快、脊柱稳定性好及无明显并发症的优点,两组在椎管减压程度及神经功能恢复进步方面效果相近。  相似文献   

20.
目的 分析和评估轴形内固定(AF)的临床应用价值。方法 对42例胸腰椎骨折患者行AF内固定。每位患者术前均行X线、CT等影像学检查。术中按Megerl法置钉常规摄定位X线片。42例中39例获得随访,平均21个月,观察内固定及神经症状恢复情况。结果 术后cobb’s角平均改善23.2。压缩椎体高度均恢复40.2%,14例合并神经系统症状患者,12例有明显改进(2例Fmnkel A级无明显改善)。结论 AF钉具有创伤小、出血少、操作相对简单安全、固定节段少等优点,特别适用于胸腰椎骨折脱位后路减压和复位需要重建脊柱稳定性的治疗。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号