首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A conventional T1-weighted spin-echo (SE) magnetic resonance (MR) imaging sequence was compared with breath-hold and non-breath-hold half- Fourier single-shot fast SE MR sequences with black-blood preparation and high spatial resolution for imaging of various cardiac diseases. The optimized single-shot fast SE sequence provided better or equal image quality in less time. Breath-hold and non-breath-hold single-shot fast SE sequences may replace the conventional T1-weighted SE sequence for first-line cardiac MR imaging.  相似文献   

2.
Distinguishing between lipid and water-containing tissues is clinically important. Current techniques rely on the chemical shift difference between fat and water resonances or differences in relaxation times of the tissues, or a combination of both. A method is presented for separating the signals of lipid protons from those of water protons by using fast spin-echo magnetic resonance imaging based on the principle that lipid protons behave differently from water protons in mul-tiecho sequences. Two images are acquired with different echo train lengths and echo spacing but with identical TEs, and then subtracted to exploit differences in the behavior of lipid and water protons in mul-tiecho sequences. The method is insensitive to B0 inhomoge-neities or susceptibility effects and provides separate lipid and water images with a high signal-to-noise ratio. The advantages of the method are demonstrated with phantom studies and clinical examples.  相似文献   

3.
Orbit: initial experience with surface coil spin-echo MR imaging at 1.5 T   总被引:1,自引:0,他引:1  
Fifty-nine cases in which surface coil MR imaging of the orbit was performed were reviewed. MR imaging was performed with spin-echo techniques at 1.5 T with both short repetition time/echo time (TR/TE) and long TR/TE sequences in all cases. In all patients short TR/TE images were obtained with small-diameter surface coils; long TR/TE images were usually obtained with a standard head coil. Surface coil MR appears to be an important adjunct in state-of-the-art orbital imaging. Orbital MR imaging may be most useful, providing information not available on computed tomography (CT), in identifying lesions in the orbital apex, superior orbital fissure, and optic canal; differentiating inflammatory pseudotumor from malignancy in clinically similar patients; characterizing lesions containing hemorrhage or other paramagnetic material; defining the posterior extent of optic pathway gliomas; and detecting abnormal flow in intraorbital vascular structures. CT seems to be superior to MR imaging in the evaluation of small perioptic meningiomas, especially those that are calcified.  相似文献   

4.
BACKGROUND AND PURPOSE: To prospectively evaluate the signal-to-noise ratio (SNR) improvement in diffusion-weighted imaging (DWI) of the spine with the use of a newly developed non-Carr-Purcell-Meiboom-Gill (non-CPMG) single-shot fast spin-echo (SS-FSE) sequence and its effect on apparent diffusion coefficient (ADC) measurements. MATERIALS AND METHODS: Twenty-four patients were enrolled after written informed consent. DWI of the spine was obtained with an echo-planar imaging (EPI)-based sequence followed by a non-CPMG SS-FSE technique. SNR and ADC values were measured over a lesion-free vertebral corpus. A quality score was assigned for each set of images to assess the image quality. When a spinal lesion was present, contrast-to-noise ratio (CNR) and ADC were also measured. Student t tests were used for statistical analysis. RESULTS: Mean SNR values were 5.83 +/- 2.2 and 11.68 +/- 2.87 for EPI and non-CPMG SS-FSE DWI, respectively. SNR values measured in DWI using parallel imaging were found to be significantly higher (P < .01). Mean ADCs of the spine were 0.53 +/- 0.15 and 0.35 +/- 0.15 x 10(-3) mm(2)/s for EPI and non-CPMG SS-FSE DWI, respectively. Quality scores were found to be higher for the non-CPMG SS-FSE DWI technique (P < .05). Overall lesion CNR was found to be higher in DWI with non-CPMG SS-FSE. CONCLUSION: The non-CPMG SS-FSE technique provides a significant improvement to current EPI-based DWI of the spine. A study including a larger number of patients is required to determine the use of this DWI sequence as a supplementary tool to conventional MR imaging for increasing diagnostic confidence in spinal pathologic conditions.  相似文献   

5.
D A Feinberg  K Oshio 《Radiology》1991,181(2):597-602
A novel technique of magnetic resonance (MR) imaging, which combines gradient-echo and spin-echo (GRASE) technique, accomplishes T2-weighted multisection imaging in drastically reduced imaging time, currently 24 times faster than spin-echo imaging. The GRASE technique maintains contrast mechanisms, high spatial resolution, and image quality of spin-echo imaging and is compatible with clinical whole-body MR systems without modification of gradient hardware. Image acquisition time is 18 seconds for 11 multisection body images (2,000/80 [repetition time msec/echo time msec]) and 36 seconds for 22 brain images (4,000/104). With a combination of multiple Hahn spin echoes and short gradient-echo trains, the GRASE technique overcomes several potential problems of echo-planar imaging, including large chemical shift, image distortions, and signal loss from field inhomogeneity. Advantages of GRASE over the RARE (rapid acquisition with relaxation enhancement) technique include faster acquisition times and lower deposition of radio-frequency power in the body. Breath holding during 18-second GRASE imaging of the upper abdomen eliminates respiratory-motion artifacts in T2-weighted images. A major improvement in T2-weighted abdominal imaging is suggested.  相似文献   

6.
7.
Magnetic resonance imaging is frequently complicated by the presence of motion and susceptibility gradients. Also, some biologic tissues have short T2s. These problems are particularly troublesome in fast spin-echo (FSE) imaging, in which T2 decay and motion between echoes result in image blurring and ghost artifacts. The authors reduced TE in conventional spin-echo (SE) imaging to 5 msec and echo spacing (E-space) in FSE imaging to 6 msec. All magnetic gradients (except readout) were kept at a maximum, with data sampling as fast as 125 kHz and only ramp waveforms used. Truncated sine radio-frequency pulses and asymmetric echo sampling were also used in SE imaging. Short TE (5.8 msec) SE images of the upper abdomen were compared with conventional SE images (TE =11 msec). Also, FSE images with short E-space were compared with conventional FSE images in multiple body sites. Short TE significantly improved the liver-spleen contrast-to-total noise ratio (C/N) (7.9 vs 4.1, n = 9, P <.01) on T1-weighted SE images, reduced the intensity of ghost artifacts (by 34%, P <.02), and increased the number of available imaging planes by 30%. It also improved delineation of cranial nerves and reduced susceptibility artifacts. On short E-space FSE images, spine, lung, upper abdomen, and musculoskeletal tissues appeared crisper and measured spleen-liver C/N increased significantly (6.9 vs 4.0, n = 12, P <.01). The delineation of tissues with short T2 (eg, cartilage) and motion artifact suppression were also improved. Short TE methods can improve image quality in both SE and FSE imaging and merit further clinical evaluation.  相似文献   

8.
9.
PURPOSETo compare conspicuousness of head and neck lesions on fast spin-echo sequences and conventional spin-echo sequences.METHODSForty consecutive patients with 61 head and neck lesions were evaluated. Lesion conspicuousness was qualitatively compared on conventional spin-echo and fast spin-echo sequences, using both spin-density and T2-weighted images. Thirty-six lesions had surgical or pathologic confirmation, and 25 were assigned a presumptive diagnosis based on clinical evaluation and imaging findings seen on conventional spin-echo T1- and T2-weighted sequences. Forty lesions were related to neoplasms; 21 lesions consisted of infectious, vascular, or inflammatory abnormalities.RESULTSFast spin-echo sequences provided improved lesion conspicuousness in 91% of spin-density images, in 77% of T2-weighted images, and in 84% of the combined spin-density and T2-weighted images.CONCLUSIONBy providing shorter imaging times and equal or superior lesion conspicuousness, long-repetition-time fast spin-echo sequences can replace long-repetition-time conventional spin-echo sequences in evaluation of the head and neck.  相似文献   

10.
Abdominal MR imaging: evaluation of a fast spin-echo sequence   总被引:4,自引:0,他引:4  
  相似文献   

11.
A new approach for producing primarily T2- and proton-density-weighted MR images in less time than the conventional long TR, long TE imaging is to reduce the TR of a double spin-echo pulse sequence and to also reduce the RF excitation flip angle to minimize the resulting T1 sensitivity. In preliminary studies with a human volunteer and five patients with various diseases of the head and neck, conventional long TR, long TE and short TR, short TE images were compared with short TR, long TE images with reduced flip angles (45 degrees, 30 degrees), which required only 40% of the imaging time of the long TR images. The latter images showed a similar contrast pattern to the conventional T2-weighted image, and contrast-to-noise measurements indicated an increase in contrast between the lesion and nearby tissue when the flip angle was reduced. Furthermore, the maximum contrast/noise per unit imaging time on the short TR, long TE image was comparable to that on the long TR, long TE image. Optimization of the flip angle with short TR allows a substantial reduction in imaging time but with a reduction in multislice capability. This technique will be most useful in areas of complex anatomy where two or more orthogonal imaging planes are required, such as the head and neck.  相似文献   

12.
13.
Two modified fast spin-echo (FSE) techniques (a 2-point and a single-scan triple-echo Dixon) were used for T2-weighted imaging of the head and neck in 7 patients along with conventional FSE with fat saturation. Both Dixon techniques provided consistent and more uniform fat suppression (FS) than conventional FSE. The 2-point Dixon technique was noted to be more susceptible to motion artifacts. The triple-echo Dixon technique offered the best scan time efficiency and overall image quality.  相似文献   

14.
The value of T2-weighted fast spin-echo imaging of the musculoskeletal system was assessed in 22 patients with various neoplastic, inflammatory, and traumatic disorders. Images were acquired with high echo number (i.e., echo train length) fast spin-echo (FSE; TR 2000 ms, effective TE 100 ms, echo number 13, lineark-space ordering), conventional spin-echo (SE; TR 2000 ms, TE 100 ms) and gradient-echo (GRE) sequences (TR 600 ms, TE 34 ms, flip angle 25°). Signal intensities, signal-to-noise ratios, contrast, contrast-to-noise ratios, lesion conspicuousness, detail perceptibility, and sensitivity towards image artifacts were compared. The high signal intensity of fat on FSE images resulted in a slightly inferior lesion-to-fat contrast on FSE images. However, on the basis of lesion conspicuity, FSE is able to replace time-consuming conventional T2-weighted SE imaging in musculoskeletal MRI. In contrast, GRE images frequently showed superior lesion conspicuity. One minor disadvantage of FSE in our study was the frequent deterioration of image quality by blurring, black band, and rippling artifacts. Some of these artifacts, however, can be prevented using short echo trains and/or short echo spacings.  相似文献   

15.
A diffusion-weighted fast spin-echo (FSE) imaging sequence for high-field MR microscopy was developed and experimentally validated in a phantom and in a live rat. Pulsed diffusion gradients were executed before and after the initial 180° pulse in the FSE pulse train. This produced diffusion-related reductions in image signal intensity corresponding to gradient (“b”) factors between 1.80 and 1352 s/mm2. The degree of diffusion weighting was demonstrated to be independent of echo train length for experiments using trains up to 16 echoes long. Quantitative measurements on a phantom and on a live rat produced diffusion coefficients consistent with literature values. Importantly, the eight- to 16-fold increase in imaging efficiency with FSE was not accompanied by a significant loss of spatial resolution or contrast. This permits acquisition of in vivo three-dimensional data in time periods that are appropriate for evolving biological processes. The combination of accurate diffusion weighting and high spatial resolution provided by FSE makes the technique particularly useful for MR microscopy.  相似文献   

16.
17.
18.
19.
The pelvis: T2-weighted fast spin-echo MR imaging.   总被引:4,自引:0,他引:4  
Fast spin-echo (SE) T2-weighted magnetic resonance (MR) imaging provides images with highly T2-weighted contrast in substantially reduced imaging times. In a prospective evaluation, fast SE T2-weighted imaging of the pelvis was compared with conventional SE T2-weighted imaging in 30 consecutive patients in whom pelvic pathologic conditions were suspected. Three reviewers independently analyzed the images for (a) overall image quality, (b) pelvic organ definition, (c) conspicuity of pelvic fluid, and (d) conspicuity of pelvic pathologic conditions. Fast SE images were rated superior to conventional SE T2-weighted images in 60% (54 of 90) of the case reviews for overall image quality, in 69% (62 of 90) for pelvic organ definition, in 63% (57 of 90) for conspicuity of pelvic fluid, and in 68% (43 of 63) for conspicuity of pelvic pathologic conditions. The fast SE examinations were typically three to four times faster than conventional SE T2-weighted examinations. No pathologic findings seen on conventional SE T2-weighted images were undetected on fast SE images. Fast SE images may replace conventional SE T2-weighted images in MR imaging of the pelvis.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号