首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The effectiveness of fibrin glue as a sealant to reduce postoperative air leaks after pulmonary lobectomy was evaluated in 28 consecutive patients between November 1988 and May 1989. A fibrin glue spray was used in 14 patients, and 14 patients served as controls. Assignment of either group was made before thoracotomy. Nine male and 5 female patients with a mean age of 63.8 years were in the fibrin glue experimental group, and 8 male and 6 female patients with a mean age of 59 years, in the control group. An equal number of complete and incomplete fissures were in each group. All fissures were handled in the same way (stapled). Two milliliters of fibrin glue was applied through a double-syringe delivery system and sprayed on the staple line and any cut surface of the inflated lung just before thoracotomy closure. The fibrin glue-treated group had a mean air leak duration of 2.3 +/- 3.7 days, chest tube drains for 6 +/- 4.1 days, and a postoperative hospitalization of 9.8 +/- 3.1 days. The control group had a mean air leak duration of 3.3 +/- 3.3 days (p = 0.94), chest tube drains for 5.9 +/- 3.9 days (p = 0.95), and a postoperative hospitalization of 11.5 +/- 3.9 days (p = 0.21). We conclude that the routine use of a fixed quantity of fibrin glue is not effective in reducing the duration of air leaks, chest tube drainage, or hospitalization after uncomplicated pulmonary lobectomy.  相似文献   

2.
Autologous fibrin glue was used in 20 patients undergoing lung resection to reduce pulmonary air leaks and improve hemostasis. The fibrinogen in the glue was prepared by ethanol precipitation of plasma separated from 88 ml of the patient's blood. The mean volume of fibrinogen concentrate +/- SD was 4.9 +/- 0.5 ml with a fibrinogen concentration of 28 +/- 5 mg/ml. The yield obtained by the separation was 81% +/- 9%. One part of fibrinogen concentrate was converted to solid fibrin by means of 0.3 parts of thrombin solution. The outcome was 6.4 ml of two-component fibrin glue. The preparation was performed in a closed system to ensure sterility, and was completed within 90 min. Pulmonary air leak decreased following sealing of the resection lines with autologous fibrin glue and the hemostasis was effective. No adverse effects were observed, and all cultures from the glue were negative. Autologous fibrin glue has the obvious advantages of safety from transmission of viral diseases and from immunological reactions. In summary, we report a new technique for preparing autologous fibrin glue with a high concentration of fibrinogen making it a safe and effective sealant of pulmonary air leak and hemostatic agent in thoracic surgery.  相似文献   

3.
Esophagogastric anastomoses: the value of fibrin glue in preventing leakage   总被引:2,自引:0,他引:2  
Disruption of an esophagogastric anastomosis can result in a high mortality despite aggressive treatment. The efficacy of fibrin "glue" to seal esophagogastric anastomoses was evaluated as a means of preventing this complication. A left thoracotomy was performed in 25 adult mongrel dogs. After esophagogastric resection, a standardized esophagogastrostomy was performed and eight interrupted sutures were used to completely close the posterior wall. The anterior wall was approximated with only three sutures, leaving four large holes between sutures. The dogs were then randomized into the control group (n = 14; no attempt to seal the leaks) or into the fibrin glue-treated group (n = 11). An average of 3.3 ml of glue was applied to the anterior wall of the anastomosis in the treated group. In the control group, 13 of 14 dogs (92.9%) died of anastomotic leak a median of 3 days after operation. In the fibrin glue-treated group, only four of 11 dogs (36.4%) died of anastomotic leaks (p less than 0.01). Dogs that survived were put to death at 14 days. Postmortem examination in all dogs revealed no deleterious effects or complications related to the glue. Postmortem examination of the one surviving control dog and the seven fibrin glue-treated dogs that did not die of sepsis revealed a healed anastomosis without abscess formation. We conclude that fibrin glue is effective in lessening the incidence of esophagogastric anastomotic leaks as employed in this experimental model.  相似文献   

4.
Because bowel and omental adhesions offer some protection when an anastomosis leaks, the effect of a fibrin glue on the leak rate was determined in a prospective animal study. EEA stapled anastomoses of the rectum were evaluated in dogs with respect to mortality, postmortem leak rate, adhesions, and the accuracy of barium enema done just before the animals were killed 7 days postoperatively. There was a reduction in fatal, free, and confined leaks which did not reach statistical significance. Adhesions were reduced. There were no false-positive barium enemas but a 7 percent incidence of false-negative results. The clinical management of a suspected anastomotic leak is discussed.  相似文献   

5.
Air leaks are a common complication of pulmonary resection. The aims of this study were to analyze risk factors for postoperative air leak and to evaluate the role of air leak measurement in identifying patients at increased risk for cardiorespiratory morbidity and prolonged air leak. From March to December 2009, 142 consecutive patients underwent pulmonary resection for malignancy and were prospectively followed up. Preoperative and intraoperative risk factors for air leak were evaluated. Air leaks were qualitatively and quantitatively labeled twice daily. There were 52 (36.6%) patients who had an air leak on day 1, and 32 (22.5%) who had an air leak on day 2. Air leak was ≥180 ml/min in 12 (37.5%) of these patients. Independent predictors of air leak on day 2 included type of pulmonary resection, presence of adhesions, and incomplete fissures. Cardiorespiratory morbidity was significantly higher (34.4%) in patients who experienced air leak on day 2 than in those who did not (10.9%) (P=0.002). Nine (75%) out of 12 patients with air leak ≥180 ml/min on day 2 had prolonged air leak (greater than five days) (P=0.0001).  相似文献   

6.
AIM: Air leaks are a common cause of morbidity and prolonged hospital stay after pulmonary lobectomy. We reviewed our experience with intraoperative fibrin glue to determine if it reduced air leak and improved patient outcomes. METHODS: Records of patients undergoing pulmonary lobectomy for benign or malignant disease over a 4-year period (1998-2001) were reviewed. Data was collected on age, sex, pulmonary function, pulmonary pathology, use of fibrin glue, duration of chest tube drainage, length of hospital stay, and postoperative complications. RESULTS: Three hundred and sixty patients underwent lobectomy. Fibrin glue was used intraoperatively to seal air leaks in 102 of the 360 patients (study group: 102;control group: 258). Fibrin glue was used at the discretion of the surgeon, with some surgeons using it routinely. The groups did not differ in age (p=0.29), sex (p=0.42), FEV1 (p=0.57), or pathology (p=0.08). There were no differences in outcomes such as operative mortality (study: 2 of 102, control 6 of 258, p=0.85), empyema (study: 0 of 102, control: 3 of 258, p=0.55), prolonged (>7 days) air leaks (study: 10 of 20; control: 20 of 258, p=0.71), or length of hospital stay (study: 6.3+/-2.5 days, control:7.7+/-7.2 days, p=0.83). The use of fibrin glue was associated with a reduction in the duration of chest tube intubation (study: 4.1+/-3.2 days, control: 5.5+/-3.8 days, p=0.001). CONCLUSION: Patients treated intraoperatively with fibrin glue had a significantly shorter duration of chest tube intubation after pulmonary lobectomy than those treated conventionally. However, the use of fibrin glue did not significantly influence more clinically relevant outcomes such as length of hospital stay and incidence of prolonged (>7 days) air leaks.  相似文献   

7.
The control of aerostasis after performing non-anatomical pulmonary resections constitutes a serious problem. The presence of an air leak in the postoperative period requires a prolonged thoracic drainage and consequently a longer hospital stay. The aim of our study was to evaluate the usefulness of fibrin glue and its effectiveness in the prevention of air leaks. At the Department of Thoracic Surgery of the National Cancer Institute of Milan, we conducted a case-control study in 90 patients submitted to metastasectomy for secondary lung cancer, removing multiple small nodules < or = 1.5 cm using the precision resection technique. We divided the patients into two groups, both of 45 subjects: group 1 treated with fibrin glue and group 2 submitted to cauterization of the pulmonary parenchyma. The patient characteristics were well matched for age, type of approach and operation, number of resections performed and type of pathology. The assessment parameters investigated were the duration of the air leak, expected complications, drainage time and length of hospital stay. In group 1 we performed fewer than 5 precision resections in 21 cases, from 5 to 10 in 16, and more than 10 in 8. In group 2 we executed fewer than precision resections in 21 cases, from 5 to 10 in 17, and more than 10 in 7. In group 1 the duration of the air leak was 2.93 +/- 1.91 days as against 6.95 +/- 7.01 days in group 2 (p = 0.000). In group 1 we had one complication (2%) (a long-term air leak lasting > 10 days), while in group 2 we had a long-term air leak in 11 cases (24%) (p = 0.000). Mean thoracic drainage time was 4.22 +/- 1.43 days in group 1, and 8.13 +/- 7.37 in group 2 (p = 0.000). The mean postoperative hospital stay was 6.22 +/- 1.43 days in group 1 compared to 10.13 +/- 7.37 days in group 2 (p = 0.000). In the group of patients treated with fibrin glue we obtained a significant reduction in drainage time, complications and postoperative hospital stay. The results of our experience show that the use of fibrin glue in non-anatomical resections with a high risk of developing air leakage is effective in reducing the expected complications, with a favourable impact also on the quality of life of patients with metasases.  相似文献   

8.

Background

We previously reported that the combined use of absorbable mesh and fibrin glue is superior to the use of fibrin glue alone to stop intraoperative air leaks. However, concern remains about whether mesh-based pneumostasis can induce the recurrence of air leaks after chest tube removal.

Methods

We reviewed our prospective database of selected patients (n?=?206) who underwent video-assisted major lung resection for cancer. Exclusion criteria included simultaneous combined resection, induction radiotherapy, entire intrathoracic adhesion, or a history of prior ipsilateral thoracotomy. We sealed any intraoperative air leaks with absorbable mesh and fibrin glue and then carried out prophylactic chest-tube drainage for 1?day.

Results

Intraoperative air leaks were detected in 133 (65%) patients. Overall, air leaks were not detected postoperatively in 186 (91%) patients, allowing chest tube removal on the day after the operation. The mean length of time for chest tube drainage was 1.2?days. A prolonged air leak (>7?days) was observed in one (0.5%) patient, and this leak resolved by itself. After chest tube removal, an air leak recurred in six (2.9%) patients during the 30?day follow-up period, necessitating chest tube reinsertion. Although the recurrence was observed more frequently after segmentectomy than after lobectomy (p?=?0.04), the recurrence was not observed more frequently in patients who had an intraoperative air leak than in patients who did not (p?=?0.3).

Conclusion

Early removal of the chest tube after pneumostasis with absorbable mesh is verified in selected patients who underwent video-assisted major lung resection for cancer. However, further attempts should be made to prevent air leaks after anatomical segmentectomy.  相似文献   

9.
We explored the effect of fibrin glue injection at the site of dural puncture on cerebrospinal fluid (CSF) leakage in a swine model. Pigs were subjected to a lumbar dural CSF puncture in the sitting position with a 17-gauge Tuohy needle. Fibrin glue 1.4 mL was injected through the same needle into the epidural space. Evans blue dye was infused through the cisterna magna 15 min later, and the appearance of dyed CSF through the skin puncture and along the needle trajectory to the dura was inspected and categorized. In seven of eight animals, the CSF leak was sealed with fibrin glue. Control animals were injected with 1.4 mL saline. A sham operation group of animals underwent cisternal dye infusion without a lumbar puncture. CSF pressure at the cisterna magna was recorded throughout the procedure. No significant differences in the leakage indicators were found between the fibrin glue-injected and sham-operated group, whereas both groups showed significant differences with respect to the control group. The fibrin glue seal was effective against CSF pressures of 24.5 [17-31] cm H(2)O. We conclude that percutaneously injected fibrin glue is effective in stopping CSF leaks after dural puncture in this animal model. IMPLICATIONS: In this swine study, we repaired a cerebrospinal fluid leak after a dural puncture by percutaneously injecting tissue adhesive. The technique of percutaneous injection of fibrin glue seems promising for the prophylaxis of headache associated with cerebrospinal fluid leakage, and may be an alternative to an epidural blood patch.  相似文献   

10.
Background The adoption of advanced laparoscopic techniques for complex surgical procedures has raised the concern that the leak rate might be higher than for open surgery, particularly in the surgeon's early experience or in difficult cases. In this study, the sealing effect of fibrin glue on leaking gastrointestinal anastomoses was evaluated in an experimental swine model. Methods A standardized gastrojejunostomy was performed on 20 female pigs (mean weight, 47.7 ± 5.7 kg). A leak was created on the anterior surface of the anastomosis. The animals were randomized to either fibrin glue or no treatment of the leak. Clinical conditions and vital signs, including body temperature, heart rate and, respiratory rate, were collected three times a day. Preoperative and postoperative complete and differential blood count and lactate dehydrogenase levels were determined. Postmortem analysis was performed when the animals were killed. Results Clinical signs of peritonitis developed in the control animals by the second or third postoperative day. Findings that confirmed the presence of an anastomotic leak at the postmortem examination were the presence of food or gastrojejunal juices in the abdominal cavity, a localized abscess, or a positive air leak test. Fibrin glue treatment prevented the development of peritonitis in all the animals. Complete sealing of the leak was observed on postoperative day 7 in all treated animals, except one in which an asymptomatic contained leak developed. The postoperative total white blood count was significantly increased in the untreated group (24.69 ± 5.5 vs 12.74 ± 3.7 103/ul p < 0.001, paired t-test), as compared with the treated group (15. 55 ± 2.4 vs 14.89 ± 2.7 103/ul; p = 0.24). Conclusion In this study, fibrin glue showed reproducible sealing effects on leaking gastrojejunal anastomoses. Fibrin glue application may be a valuable approach for the treatment of gastrointestinal anastomotic leaks. 2004 Oral Presentation at the annual meeting of the Society of American Gastrointestinal and Endoscopic Surgeons (SAGES) in Denver, CO, USA.  相似文献   

11.
BACKGROUND: In contrast to the rare large-airway bronchopleural fistulas after lung resection, peripheral or alveolar air leaks (AAL) are very common, often prolong hospital stay, increase utilization of resources, and on occasion result in significant morbidity. Various adjuncts have been used in attempts to reduce AAL. One of these, the topical application of fibrin glue, has to date failed to demonstrate efficacy in small clinical trials. This study reexamines the role of fibrin glue in routine lobar and wedge pulmonary resections. METHODS: Of 113 patients enrolled, 13 became ineligible because of intraoperative findings. The remaining 100 patients were randomly assigned to one of two groups at the conclusion of lung resection, regardless of the presence or absence of identifiable air leak. The control group received no additional intervention. The experimental group underwent application of 5 mL of fibrin glue delivered by a pressurized, aerosolized spraying mechanism. Postoperatively a blinded clinical observer recorded outcomes including the incidence and duration of AAL, prolonged AAL (PAAL), the volume of pleural drainage, the time to tube removal, and the postoperative length of stay (LOS), as well as any complications related to treatment. RESULTS: Both groups were comparable with regard to demographics, diagnoses, and procedures. Statistically significant reductions were found in the experimental group in the overall incidence of AAL (34% versus 68%, p = 0.001), mean duration of AAL (1.1 versus 3.1 days, p = 0.005), mean time to chest tube removal (3.5 versus 5.0 days, p = 0.02), and the incidence of PAAL (2% versus 16%, p = 0.015). There was no significant difference in the volume of chest tube drainage or LOS (4.6 days glue and 4.9 days control, p = 0.318). There were no complications related to the use of fibrin glue. CONCLUSIONS: Aerosolized fibrin glue appears to be safe and effective in reducing AAL. The overall incidence of AAL was reduced by 50% and PAAL occurred in only 1 treated patient (2% versus the usually reported 15%). Further studies with this and other methods are required to delineate routine versus selective use, to compare methods, and clarify cost benefit.  相似文献   

12.
To elucidate the safety of fibrin glue application, antibody formation against fibrinogen and thrombin was studied in rabbits. The pathophysiology of developed antibodies was tested by an intravenous challenge with both components and by related blood pressure measurements. All fibrin glue-treated animals developed antibodies against both components. The quantity of antibodies against thrombin (20.4 mg/mL) was higher than the quantity against fibrinogen (0.38 mg/mL). The intravenous challenge with both components resulted in a significant and long-lasting blood pressure decrease to about 50% of the control values, indicating that these antibodies can induce circulatory disorders by antigen-antibody reaction, activation of the complement cascade, and liberation of histamine. Since rabbits promptly produce antibodies against antigenic material and humans do not, the results of this investigation suggest that fibrin glue should be used with caution in humans.  相似文献   

13.
The purpose of this randomized trail was to investigate the effect of using a pedicled pericardial fat pad fixed with fibrin glue on postoperative alveolar air leakage. Thirty consecutive patients with lung cancer, who had moderate alveolar air leaks after pulmonary resection, were randomized into two groups: in group A fibrin glue was applied onto the surface of the leaking raw lung and in group B, after applying fibrin glue in the same manner as in group A, a pedicled pericardial fat pad was immediately fixed to the leaking lung surface with fibrin glue. The duration of the postoperative air leakage and chest tube drainage was recorded. In 6 of 15 patients in group B the air leakage ceased within the first 24 h after pulmonary resection, while in group A only 1 of 15 patients showed a cessation of the air leakage, and a significant difference was noticed between the two groups (P = 0.0309). The duration of the postoperative air leakage was 4.8 ± 4.6 days in group A and 3.6 ± 3.4 days in group B. The pedicled pericardial fat pad fixed onto the surface of the leaking raw lung using fibrin glue was found to reduce alveolar air leakage after pulmonary resection. Received: January 11, 2001 / Accepted: September 11, 2001  相似文献   

14.
BACKGROUND: Intraoperative pulmonary air leakage is one of the most troublesome complications in video-assisted thoracoscopic surgical procedures. We developed a sealing procedure using gelatin-resorcinol-formaldehyde-glutaraldehyde (GRFG) glue for pulmonary air leaks during such operations. METHODS: Formaldehyde-glutaraldehyde (FG) jelly is prepared by mixing FG fluid with 2.5% sodium carboxymethyl cellulose to make the FG fluid viscous. We performed an adhesion-strength test to determine the optimum ratio of gelatin-resorcinol mixture to FG jelly and then conducted an air leakage test on swine lung to compare the sealing effect between fibrin and GRFG glues. To study the histotoxicity of the GRFG glue, the sealant was applied to injured rabbit lung, and the rabbits were followed for 1 day to 188 days. For clinical studies, we developed an endosyringe to apply the GRFG glue on the target site during video-assisted thoracoscopic surgical procedures and used this technique in 21 patients with intraoperative air leaks. In addition, the side effects of GRFG glue application were studied in 52 patients in whom glue was used in several ways during lung operations. RESULTS: The results of the adhesion-strength test favored a 2:1 gelatin-resorcinol to FG ratio. The mean pressure required to produce air leakage was significantly higher with GRFG glue than with fibrin glue (p<0.001). No critical histologic damage was seen in the rabbit lung, and the glue persisted on the lung surface for 188 days after sealing. Clinical application of the glue in 21 patients resulted in complete stoppage of air leakage during operation and long afterward, except in 1 patient with a late-onset lung fistula. The FG jelly helped prevent glue spillage at the target site, regardless of angle. A transient rise in temperature up to 38.60C was observed as a side effect 7 days after operation in 5 (9.6%) of the 52 patients. CONCLUSIONS: A GRFG glue using FG jelly seals pulmonary air leaks effectively, simply, and safely during video-assisted thoracoscopic surgical procedures.  相似文献   

15.
Background: Aerostasis control in multiple resections for metastatic pulmonary diseases is a real problem. Long-term air leaks prolong postoperative hospitalization and result in an additional financial burden on the healthcare system. We focused our study on the evaluation of fibrin glue (Tissucol) as an effective means to minimize or prevent air leaks.Methods: We initiated a case-control study whereby 100 patients underwent precision resections for lung metastases. The subjects were divided into 2 groups, both with 50 patients: group 1 was treated with fibrin glue and group 2 with cauterization. Evaluation parameters consisted of the following: air leak duration, expected complications, drain time, and in-hospital stay.Results: In group 1, air-leak time was 2.68 ± 1.72 days, versus 7.80 ± 8.52 for group 2 (P < .001). In group 1, there were 2% complications, whereas in group 2 there were 28% (P < .001). Drain time was 4.54 ± 1.83 days for group 1 and 9.54 ± 8.35 for group 2 (P < .001). In-hospital stay was 6.54 ± 1.83 days for group 1 and 11.54 ± 8.35 for group 2 (P < .001).Conclusions:In the group treated with fibrin glue, we observed significant advantages. Our experience shows that the use of fibrin glue can improve aerostasis control in nonanatomical resections with high risk of air leak.Presented at the 55th Annual Cancer Symposium of the Society of Surgical Oncology, Denver, Colorado, March 14–17, 2002.  相似文献   

16.
BACKGROUND: Prolonged air leak is the major limiting factor in early hospital discharge following pulmonary resection. The purpose of this study was to determine whether the use of bovine pericardial strips as a buttress along the lung staple line would decrease air leaks and hospital stay after lobectomy and segmentectomy. METHODS: This was a multicenter trial consisting of 80 patients undergoing pulmonary resection, randomly assigned to the control group (40 patients) or treatment group (40 patients). The treatment group had reinforcement with bovine pericardium. RESULTS: No statistical differences were noted in the mean intensive care unit length of stay (p = 0.9), number of days with a chest tube (p = 0.6), or total length of stay (p = 0.24). Increased air leak duration was associated with assignment to the control group (r = 0.27, p = 0.02). The mean duration of air leak was 2 days and the mean time to chest tube removal was 5.9 days in patients with a buttressed staple line compared to 3 days and 6.3 days, respectively, for patients with nonbuttressed staple lines. CONCLUSIONS: Within the data of this study, no statistical differences were noted between buttressed and nonbuttressed patients. However, the trend toward shortened air leak time and tube removal time was apparent in the buttressed group. With greater number of patients studied, it is likely that the cost of bovine pericardium would be justified by shorter air leak duration and hospitalization.  相似文献   

17.
Although various materials have been used for reinforcement in lung-volume-reduction surgery to buttress pulmonary staple-line, absorbable materials are not available for use in thoracoscopic surgery. Moreover, even nonabsorbable types of reinforcements have been used only for lung volume reduction surgery. However, elderly patients with spontaneous pneumothorax secondary to emphysematous lung are well treated with staple-line reinforcement. The authors developed a new type of polyglycolic acid felt to buttress staple-line. This felt is absorbable, easier to cut with a stapler knife than is the conventional polyglycolic acid felt, and inexpensive enough to use for various types of thoracic surgeries for emphysematous lungs in Japan, and it can be attached to staplers with a small amount of fibrin glue. These strips were used to reinforce pulmonary staple lines for resection of emphysematous lungs in 14 patients: pulmonary emphysema (n = 1), bilateral giant bullae (n = 1), ipsilateral giant bullae (n = 6), spontaneous pneumothorax with multiple bullae in an emphysematous lung (n = 5), and lung cancer in a patient with pulmonary emphysema (n = 1). There were no air leaks during surgery. Air leaks were noted in three patients after surgery. In two patients, the air leaks stopped within 2 weeks. In one patient, the air leak was found to originate from an untouched lobe during reoperation. No infection or allergic reaction developed in a patient during a mean follow-up of 12 months (range, 1 to 24 months).  相似文献   

18.
BACKGROUND: Air leak is a problem commonly occurring in lung and thoracic operations. In this study, a rapidly curable hydrogel glue was prepared as the seal for lung air leak. METHODS: Mixing an aqueous solution of gelatin and poly(L-glutamic acid) with a water-soluble carbodiimide produced a hydrogel. The sealing effect on the air leak wound of rat lung was compared with that of conventional fibrin glue. RESULTS: The gelatin-poly(L-glutamic acid) hydrogel glue was solidified as rapidly as the fibrin glue, and was significantly more effective in sealing the lung air leak than the fibrin glue. Approximately 80% of the lungs treated with the hydrogel glue exhibited no air leak at the lung pressure of 50 cm H2O. Urea addition could prevent spontaneous gelatination of the mixed solution at room temperature and did not affect the hydrogel sealing effect. The bonding strength of the hydrogel glue both with and without urea to the lung tissue was significantly higher than that of the fibrin glue. CONCLUSIONS: We concluded that this strong lung adhesion of the gelatin-poly(L-glutamic acid) hydrogel glue resulted in its superior sealing effect.  相似文献   

19.
Prolonged air leak after thoracic procedures was successfully treated in 11 of 12 patients under local anesthesia using video thoracoscopic instillation of fibrin sealant over the site of the leak. No related complications occurred. This method should be considered an effective option for the treatment of persistent pulmonary air leaks.  相似文献   

20.
Recent reports suggest that fibrin glue can be used to seal porous vascular grafts prior to insertion, but this ability has not been quantitatively compared to existing methods. We compared blood loss from and handling characteristics of grafts pretreated with either fibrin glue (FG) (Tisseel), albumin autoclaving (AA), or blood preclotting (BP). Five 6-cm segments of 6-mm internal diameter grafts, both knitted and woven double velour Dacron were treated in each group (30 specimens). Human blood was forced through the BP group until clotted; AA segments were soaked in 25% human albumin and autoclaved for 10 min; FG segments were treated with a topical application of Tisseel (0.5 ml/graft) followed by treatment with topical thrombin + CACl (0.5 ml/graft). Graft ends were sealed and attached to a transducer/syringe pump mechanism which pumped heparinized human blood into the graft at 100 mm Hg intraluminal pressure. All blood that leaked through the grafts over 2 min was collected and the amount was averaged for the five grafts in each group. Graft handling was characterized as either pliable or stiff. Blood pretreatment caused 21 +/- 2 and 13 +/- 4 cc/2 min of leak in knitted and woven grafts, respectively. Albumin autoclaving resulted in 9 +/- 2 and 1 +/- 0.5 cc of leak (P less than 0.01 compared to blood), while fibrin glue produced 2 +/- 2 and 0.4 +/- 0.5 cc leaks (P less than 0.01 compared to blood). Both blood and fibrin glue produced soft pliable grafts, while albumin pretreatment resulted in stiff grafts.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号