首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Rick L. Nissen 《The Laryngoscope》1998,108(11):1669-1673
Objective: The success and safety of argon lasers in stapedotomy surgery is now well documented. This study reviews results in problematic situations in which the argon laser may be of particular advantage to successful completion of the stapedotomy procedure. Study Design: Retrospective chart review. Methods: A retrospective review of the author's most recent 200 stapedotomy cases was performed, identifying 32 patients who at surgery were either found to have a prolapsed dehiscent facial nerve (three cases), developed a floating footplate (eight cases), or were undergoing a revision stapedotomy (21 cases). Four-frequency, pure-tone average air and bone conduction thresholds were computed before and after surgery. Success was defined as closure of the air-bone gap to within 10 dB, while an air-bone gap within 20 dB was considered improvement. Results: Successful closure of the air-bone gap was achieved in all eight patients with a mobilized footplate, in all three patients with a prolapsed dehiscent facial nerve, and in 43% of the patients undergoing a revision stapedotomy. The rate of improved air-bone gap in the revision cases was 62%. In one revision stapedotomy patient a decrease in speech discrimination occurred. Otherwise, there were no cases of sensorineural hearing loss. Neither intraoperative nor postoperative dizziness was reported by any patient, and all were discharged on an outpatient basis. Conclusion: The argon laser was found to be safe, effective, and a valuable adjunct for the difficult stapedotomy cases when unexpected obstacles such as a prolapsed dehiscent facial nerve or a mobilized footplate are encountered, as well as for the planned, more difficult revision cases. Laryngoscope, 108:1669-1673, 1998  相似文献   

2.
Small fenestra stapedotomies with and without KTP laser: a comparison   总被引:1,自引:0,他引:1  
The results of 33 small fenestra stapedotomies performed using conventional techniques were compared with the results of 33 stapedotomies performed using the argon or KTP laser. The ossicular chain was reconstructed using a Teflon wire piston of 0.6 mm diameter, and follow-up was at least 1 year. Over-closure of the air-bone gap or closure to within 10 dB was accomplished in 91% of the laser-treated group versus 72% of the conventionally treated group (p less than 0.10). The hearing results were statistically better in the laser group (p less than 0.05). Transient delayed vestibular symptoms, lasting from 1 to 3 weeks, were present in 39% of the laser-treated group and in 12% of the patients treated by conventional techniques (p less than 0.05). The KTP laser stapedotomy, using a micromanipulator mounted on the microscope, is a safe, efficient technique that reduces some of the technical difficulties associated with conventional stapes surgery. The main advantage of the laser is that it enables the surgeon to make an atraumatic, bloodless opening in a fixed or mobile stapes footplate without mechanical manipulation of the stapes. Using a lower wattage to vaporize the footplate and waiting several seconds between laser bursts may decrease the incidence of postoperative vestibular symptoms. The use of the KTP laser in stapes surgery represents a major advance in surgery for otosclerosis.  相似文献   

3.
OBJECTIVE: The aim of this study was to evaluate the hearing results of revision stapes surgery performed because of previously failed operations and to determine the causes of failure. STUDY DESIGN: Retrospective review of revision stapes operations. SETTING: Tertiary referral center. PATIENTS: Sixty-three consecutive revision stapes operations were performed in 56 patients over a period of 12 years (1992-2004). The indication for revision surgery was recurrent or persistent air-bone gap greater than 20 dB after primary surgical treatment of otosclerosis of the oval window. RESULTS: All patients were operated on to improve hearing. Sixty-three revision stapes operations resulted in closure of the air-bone gap to 10 dB or less in 52.4% of cases. The average postoperative air-bone gap was 13.1 dB, and the mean pure-tone average improvement was 12.9 dB. In six patients (9.5%), revision surgery produced no change in hearing, and in four (6.3%) the hearing decreased by 5 dB or more. In one patient, the operation resulted in a profound hearing loss. Prosthesis malfunction was the most common primary cause of failure (60.3%). The original prosthesis was replaced with a new one in 48 cases. In 30 of these (62.5%), closure of the air-bone gap to within 10 dB was achieved. In 15 cases, the prosthesis was not replaced, and in only four of these (26.7%), closure of the air-bone gap within 10 dB was obtained (p < 0.022). CONCLUSION: Revision stapes surgery is less likely to be successful than the primary operation. Closure of the air-bone gap to within 10 dB was achieved in 52.4% of patients. The success rate was better in cases where the original prosthesis was replaced with a new one. The risk for decreased bone-conduction threshold does not seem to be higher than in primary surgery.  相似文献   

4.
Fifty of the 810 patients who underwent stapedotomy for otosclerosis from 1969 through 1988 were randomly chosen for follow-up of at least 5 years. Most of the patients (65%) had follow-ups of 10 years after stapedotomy, but another 50 patients who underwent stapedectomy had follow-ups of longer than 10 years. In 50 patients, stapedectomy under local anesthesia was performed by removal of the footplate of the stapes, using an endaural incision, and covering the oval window with Gel-foam®. In the other 50 patients, stapedotomy was performed under general anesthesia, using an endopreauricular incision, making a small hole in the footplate, and covering the hole only with blood from the surgical area. Although both groups showed improvement in hearing after the operation, the air-bone gap in the stapedotomy group was significantly better than that in the stapedectomy group. The use of the endopreauricular incision under general anesthesia was preferable to endaural incision under local anesthesia because the operative field was wider, more convenient for the surgeon, and conducive to patient safety. There were no significant complications in either group. Our experience suggests that stapedotomy is the procedure of choice for otosclerosis.  相似文献   

5.
Osteogenesis imperfecta (OI) is a connective tissue disorder characterized by osseous fragility, blue sclerae and hearing loss. In order to assess the impact of stapedotomy on improving hearing on OI, a retrospective, one-group, pre-test-post-test design was used to compare the pre-operative and post-operative audiograms of nine OI patients, treated with stapedotomy for their mixed hearing loss. Operative findings included fixation or thickening of the stapes footplate with normal superstructure configuration and hypervascularization of the promontory mucosa. Immediate post-operative results showed a significant improvement (p < 0.05) from 250-4000 Hz in air conduction and from 250-2000 Hz in bone conduction. A significant closure of the air-bone gap between 250-2000 Hz was also achieved (p < 0.05). The long-term results remained satisfactory with a mean threshold shift of 8 dB HL and an almost unchanged air-bone gap. These satisfactory results and the lack of complications make stapedotomy an appealing method for the management of OI-associated hearing loss.  相似文献   

6.
Surgical treatment of tympanosclerosis   总被引:5,自引:0,他引:5  
OBJECTIVE: To report the hearing results of the surgical treatment of tympanosclerosis. STUDY DESIGN: A retrospective review of surgically treated cases of tympanosclerosis. SETTING: A tertiary referral center. PATIENTS: One hundred fifteen patients with middle ear tympanosclerosis operated on between 1987 and 1996, with an average age of 36 years (range 18-59 years). Cases were classified into four groups according to Wielinga and Kerr. Those with an associated cholesteatoma were excluded. INTERVENTION: Depending on the ossicular status, either mobilization of the major ossicles or epitympanic bypass procedure, mobilization of the stapes or stapedectomy. MAIN OUTCOME MEASURES: The postoperative pure-tone average was compared with the preoperative levels by use of conventional audiometry. The air-bone gap was measured. RESULTS: The average postoperative air-bone gap was 18.0+/-10.21 dB in the type II group (attic fixation of the malleus-incus complex with a mobile stapes). 21.8+/-9.5 dB in the type III group (mobile malleus-incus complex, if present, with stapes footplate fixation), and 22.92+/-10.03 dB in the type IV group (fixation of both the stapes footplate and the malleus-incus complex). Patients with a fixed malleus and mobile stapes had significantly better hearing results than those with stapes fixation (p = 0.042, Mann-Whitney U test). CONCLUSION: In ossicular attic fixation, atticotomy and mobilization of ossicles yielded better results than did the epitympanic bypass procedure. The difference, however, did not reach statistical significance. Patients with fixed stapes treated with stapedectomy displayed good hearing results immediately after surgery, but the air-bone gap deteriorated after some time.  相似文献   

7.
Abstract

Background: In otosclerosis mixed hearing loss is the most frequent symptom and arises when the focus involves the stapes footplate. Surgeons usually prefer to wait a minimum air-bone gap of 25 – 35?dB before surgery.

Objectives: To evaluate the outcome of microdrill stapedotomy for otosclerosis in patients with a preoperative air-bone gap (ABG) <25?dB versus patients with a preoperative gap ≥ 25?dB.

Material and methods: For this retrospective study, the outcomes and complications after microdrill stapedotomy were compared between adult patients with a preoperative small ABG (n?=?127, ABG <25?dB) and those with a large ABG (n?=?254, ABG ≥25?dB).

Results: The postoperative ABG was significantly smaller than the preoperative ABG (p?<?.05) in both groups; there were no differences in complications rates (severe sensorineural hearing loss, footplate fracture or early postoperative vertigo) between the two groups.

Conclusions: Our findings show that microdrill stapedotomy is safe and can be performed even in patients with a preoperative small ABG without increasing the risk of sensorineural hearing loss due to inner ear damage.  相似文献   

8.
OBJECTIVE: The objective of this study was to assess whether the use of the erbium: yttrium-aluminum-garnet (Er:YAG) laser has negative effects on inner ear function and to compare the short- and long-term hearing outcome of patients undergoing conventional stapedotomy versus laser stapedotomy. STUDY DESIGN: Retrospective review of prospectively collected audiometric data of patients with otosclerosis operated on by one experienced surgeon. SETTING: Academic tertiary referral center. PATIENTS: A total of 266 stapes surgeries were evaluated for intraoperative findings, of which 209 patients were evaluated for preoperative and postoperative hearing thresholds after a 6- to 452-week (mean, 22 wk) audiological follow-up. INTERVENTION: One hundred fifteen (43%) of the operations were performed conventionally, using manual perforators for stapedotomy (Group A); in 115 (43%) surgeries, the perforators were used in combination with the Er:YAG laser (Group B), and in 36 (14%) operations, the Er:YAG was used exclusively for footplate perforation (Group C). MAIN OUTCOME MEASURES: Pure-tone audiometry was performed before surgery, 2 days postoperatively (bone conduction only) and at 5, 26, and 57 weeks postoperatively. RESULTS: A postoperative temporary threshold shift of the bone conduction could be found in all groups. In Group C, where the laser was used exclusively for footplate perforation, this threshold shift was not only the most significant, but also-in contrast to the other groups-not totally reversible. In all techniques, a satisfactory air-bone gap closure could be achieved. The best long-term results (96% of the patients had 相似文献   

9.
OBJECTIVE: To evaluate the hearing results of stapes surgery with two different titanium stapes prostheses. A crimping and a non-crimping prosthesis. METHODS: Retrospective analyses were carried out on the pre- and postoperative hearing results obtained after 126 primary stapedotomies with two different prostheses in patients with otosclerosis. Sixty-three patients had a stapedotomy with a K-piston Titanium (No. 1006107) type and 63 patients received a CliP-piston àWengen Titanium (No. 1006807) type after stapedotomy. The results were compared according to mean audiometrical parameters. A Chi-square Test analysis (a contingency table) was performed with odds ratio to analyze this retrospective case-control study. RESULTS: The hearing results of both titanium stapes prostheses were comparable. There was no difference in the final hearing results between the two pistons studied. No statistically significant difference between the postoperative air-bone gap closures by the two titanium stapes prostheses studied could be demonstrated. CONCLUSIONS: Because of the different properties of the two titanium piston studied (CliP-piston àWengen Titanium type, no crimping and K-piston Titanium crimping necessary) a difference in the closure of the air-bone gap could be suspected. This comparative study could not demonstrate a statistical better air-bone gap closure for one of the titanium pistons. Both stapes prostheses showed good results in reconstruction of the hearing loss due to otosclerosis.  相似文献   

10.
OBJECTIVE: Manual piston malcrimping in stapedotomy may be the major cause of the occurrence of the significant, interindividual variations of postoperative air-bone gap (ABG), air-bone gap closures (ABGC), and postoperative recurrences of conductive hearing loss. To eliminate the effects of manual crimping on stapedotomy outcomes, the self-crimping, shape memory alloy Nitinol stapes piston was investigated and hearing evaluated. STUDY DESIGN: Prospective, preliminary case-control study in a tertiary care referral center. METHODS: Sixteen patients with otosclerosis undergoing reversed stapedotomy using the Nitinol stapes piston were matched to reference patients out of our conventional titanium piston database. The effects of the self-crimping Nitinol piston on the postoperative ABGC, the postoperative air-bone gap (ABG) variations, and the postoperative short-term hearing results were investigated 3, 6 and 9 months postoperatively. These data were statistically compared with the results of the control patients in our titanium stapes piston database. RESULTS: The mean postoperative ABG and the interindividual variations of the postoperative ABG were significantly smaller in the Nitinol group, the extent of ABGC greater in the Nitinol piston group, but not significant. The postoperative short-term stability of ABGC was similar in both groups. No infections or adverse reactions occurred during follow-up. CONCLUSION: Our preliminary results suggest that the self-crimping shape memory alloy Nitinol stapes piston eliminates the limitations of manual malcrimping in stapedotomy, thus optimising the surgical procedure. This allows reliable, safe, and consistent air-bone-gap closure in patients with otosclerosis up to 1 year after surgery.  相似文献   

11.

Objective

The aim of this study was to evaluate the hearing outcomes and complications of stapedotomy in which the stapes superstructure was preserved (Takagi’s stapedotomy). In this surgical approach, the lenticular process of the incus rather is removed, than the superstructure of the stapes.

Methods

A single-center retrospective observational study was performed. We included all patients having Takagi’s stapedotomy for otosclerosis between January 2005 and April 2016. Both primary and revision stapes surgery were included. We evaluated audiometric outcomes and surgical complications.

Results

Twenty-four patients who underwent stapedotomy preserving superstructure were included in this study. The postoperative air-bone gap at 1 year postoperatively was?≤10 dB in 66.7% of patients and?≤20 dB in all cases. In longer follow-up period, elevation of the air-bone gap was not observed over the 5 postoperative years in available cases. The postoperative air-bone gap was?≤10 dB in 72.2% at 3 years and 81.8% at 5 years postoperatively.

Conclusion

Takagi’s stapedotomy restore ossicular conduction without the removal of superstructure of stapes. The air-bone gap did not get worse in long-term follow-up, although audiometric results would be unsatisfactory. Further larger studies are needed to evaluate the efficacy and safety of Takagi’s stapedotomy.  相似文献   

12.
OBJECTIVE: The objective of this study was to analyze functional results after stapes surgery in patients with congenital nonprogressive conductive deafness resulting from an isolated fixation of the stapes according to age and surgical procedure. STUDY DESIGN: The authors conducted a retrospective case series from March 1993 to December 2003 in patients from two tertiary referral centers. METHODS: Twenty-eight patients were operated on by stapedotomy or partial stapedectomy using Teflon stapes prostheses. The median age at surgery was 14.2 years (range, 8.3-29.1 years). Main outcome measures were clinical and audiometric evaluation before and after surgery. Mean air conduction (MAC) and bone conduction (MBC) thresholds were recorded at 0.5, 1, 2, and 4 kHz. The evaluation of functional outcome was based on the MAC gain, the MBC comparison, and the mean postoperative and residual air-bone gaps. RESULTS: The median preoperative MAC was 50 dB (range, 19.0-65.0 dB) with a 35.0 dB median dB air-bone gap. With a mean follow up of 19 months, postoperative hearing improvement was statistically significant: median gain of 32.5 dB (P<.001) and median residual air-bone gap of 3.5 dB. The MBC was also statistically improved with median pre- and postoperative MBC of 11.5 and 6.5 dB, respectively (P<.001). Results were not dependent on the age group or type of surgery (stapedotomy or partial stapedectomy). No perceptive hearing loss was observed despite one gusher case. CONCLUSION: Surgical treatment of isolated congenital stapes ankylosis allows good functional results regardless of age or type of surgery.  相似文献   

13.
目的:比较治疗耳硬化症不同术式的疗效。方法:回顾性分析1993~2005年行手术治疗且资料完整的耳硬化症患者70例(76耳)的临床资料,按术式分为3组:镫骨全切除术30例(33耳),足板小孔开窗术24例(27耳)和镫骨撼动或提高术16例(16耳),统计3组患者术后各频率段气骨导差闭合、骨导损失及眩晕发生率等指标,比较3种术式问的差异,同时比较镫骨撼动术5例(5耳)与镫骨提高术11例(11耳)2组手术亚型间的疗效差异。结果:3种术式术后言语频率气骨导差闭合无明显差异,但在高频气骨导差改善及减少术后高频感音神经性听力损失和眩晕方面,足板小孔开窗术和镫骨撼动或提高术明显优于镫骨全切除术,并有统计学意义。镫骨撼动术与镫骨提高术无论在听力改善或术后并发症发生率方面差异均无统计学意义。结论:3种术式在提高耳硬化症患者的听力方面均具有较好的疗效,其中以足板小孔开窗术疗效最佳,其次是镫骨撼动或提高术,并且在减少术后并发症方面均优于镫骨全切除术。足板小孔开窗术是治疗耳硬化症较理想的术式。  相似文献   

14.
Obliterative otosclerosis has been a challenge since the advent of stapes surgery. "Drill-out" procedures have had a generally poorer prognosis than conventional stapes surgery because of excessive bleeding, acoustic trauma from the burr, and reclosure of the oval window by otosclerosis. In this report, we describe our early experience using a hand-held fiberoptic argon laser for small fenestra stapedotomy in 10 cases of obliterative otosclerosis. Closure of the air-bone gap to within 10 dB was seen in 100% of the patients. There was no significant sensorineural hearing loss, vertigo, or facial weakness. Argon-laser stapedotomy using a hand-held fiberoptic system is a safe and effective alternative to drill-out stapedotomy in cases of obliterative otosclerosis.  相似文献   

15.
One of the problems in the stapes surgery is the floating footplate. The frequency of incidence of this complication is 2% to 5.8% of all operations. The authors present the results of stapes operations in a group of 28 cases (2.5%) from all the 1120 operations, in which the surgeon experienced a floating footplate. The hearing results were evaluated on the base of the average gain of air-conduction thresholds and air-bone gap levels at 500, 1000, 2000 and 3000 Hz. The improvement of hearing we observed in 24 patients, 4 patients heard worse.  相似文献   

16.
OBJECTIVE: Hearing results after 23 implantations of a newly designed titanium-clip stapes piston prosthesis (the àWengen Clip Piston prosthesis) in patients with otosclerosis were evaluated. This new type of stapes piston was designed to avoid the crimping onto the incus in stapedotomy. This one clip fits all designs and enables solid fixation by clicking the prosthesis onto the long process of the incus without crimping. STUDY DESIGN: A retrospective pilot study was carried out by microcomputer of the preoperative and postoperative audiological results of patients in whom the titanium-clip stapes piston prosthesis was implanted. SETTING: Ear, nose and throat department of Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands. PATIENTS: 23 Patients underwent a stapedotomy for hearing improvement suffering from otosclerosis. implantations of a newly designed titanium-clip stapes piston prosthesis (the àWengen Clip Piston prosthesis) in patients with otosclerosis were evaluated. INTERVENTION(S): The stapedotomy was performed with the àWengen Clip Piston prosthesis. MAIN OUTCOME MEASURE(S): Pre and postoperative audiograms were used to evaluate the hearing gain improvement with the new stapes piston. Especially we looked at the airbone gap closure and the sensorineural hearing after the surgical procedure and compared these with the ones before surgery. RESULTS: The hearing results showed a closure of the pure-tone average air-bone gap to within 10 dB in 56.6% of cases (10 of 23 implantations) and to within 20 dB in 100% (23 of 23 implantations). A residual air-bone gap of greater than 20 dB was seen in the present pilot study. Postoperative overclosure of bone-conduction thresholds was discovered only for the frequency of 2 kHz. Sensorineural hearing loss greater than 10% did not occur, and there was no decline in the speech discrimination. CONCLUSIONS: The use of a newly designed titanium-clip stapes piston prosthesis with a diameter of 0.4 mm gives good results in cases of stapedotomy for otosclerosis. The titanium-clip design is a new development in the evolution of stapes piston prostheses. Surgical introduction, placement, and fixation are not always easy, depending on the anatomy of the middle ear and the thickness of the fixation area on the long process of the incus.  相似文献   

17.
We performed a retrospective chart study (including surgeon's notes and audiometric results) and an analysis of the archival temporal bones from a patient who had undergone surgery for stapes mobilization in both ears. The stapes footplate was submerged into the vestibule on the right (as a complication of surgery) and absent on the left. One interesting finding was that the patient's hearing had improved on the right despite the presence of the depressed footplate and that the air-bone gap had widened on the left despite the absence of complications on that side.  相似文献   

18.
PURPOSE: The primary use for the laser in otosclerosis surgery is to create a stapes footplate fenestration that obviates the need for mechanical footplate removal. Experimental studies that evaluate the potential safety of visible (argon and potassium-titanyl-phosphate [KTP]) and invisible (CO2) light laser systems in stapes surgery report conflicting results. The purpose of this study is to compare the clinical safety and efficacy of the CO2 and argon laser systems when used for primary laser stapedotomy. MATERIALS AND METHODS: A retrospective case review of 124 primary laser stapedotomies using either the argon (n = 59) or CO2 (n = 65) laser was performed. Data consisted of pre- and postoperative air and bone conduction audiometry, speech discrimination scores (SDS), intraoperative findings, and postoperative complications. Between group differences (argon v CO2) were sought using standard statistical methodology. RESULTS: The argon and CO2 laser groups were comparable with regards to age, sex, preoperative air-bone gap, and laterality. Mean preoperative air and bone conduction pure-tone average (PTA) and SDS were somewhat higher in the CO2 laser group (P < .05). Postoperatively, both groups showed similar results in mean change in air conduction PTA, air-bone gap, and SDS, as well as in the frequency of complications. There were no anacoustic ears in either group. CONCLUSIONS: The results suggest that the argon and CO2 laser systems are comparable with regards to safety and efficacy when used by experienced surgeons for stapedotomy.  相似文献   

19.
OBJECTIVE: This study reports the results of 112 primary stapedotomies and 13 revision stapedotomies performed by the senior author. STUDY DESIGN: Retrospective case review of all primary and revision stapedotomies performed at University Hospital between 1994 and 1999. All patients in this series had otosclerosis and underwent stapedotomy using a 0.6-mm diameter platinum wire/Teflon piston prosthesis. The air-bone gap was calculated as the difference between the preoperative boneconduction and the postoperative air-conduction thresholds. The average follow-up time post-stapedotomy to audiometric testing was approximately 2.5 months. OUTCOME MEASURES: An average air-bone gap closure at 500, 1000, and 2000 Hz to 10 dB or less was used as the criterion for success. The effects of stapedotomy on speech reception thresholds (SRTs), speech discrimination scores (SDSs), and airconduction thresholds are also reported. RESULTS: In primary stapedotomy, an air-bone gap closure of 10 dB or less was achieved in 85.7% of patients. A significant hearing gain was achieved at all frequencies (250-8000 Hz), with the greatest benefit being achieved at the lower frequencies. The SRT was significantly improved post-stapedotomy by an average of 26.7 dB, and no significant change was found in the SDS. In revision stapedotomy, 38.5% of patients had a significant hearing gain at 250 to 4000 Hz. The SRT was significantly improved postoperatively by an average of 12.7 dB, and no significant change was found in SDS. Overall complication rates were similar to other series with two cases of partial hearing loss (1.6%), one incus fracture (0.8%), one large tympanic membrane perforation (0.8%), and one perilymphatic fistula (0.8%), which was successfully repaired. No patients in this series experienced complete sensorineural hearing loss, facial nerve injury, worsened tinnitus, or reparative granuloma. CONCLUSIONS: The results of this study are comparable to other similar studies examining the use of stapedotomy in patients with otosclerosis. The high success rate and low incidence of serious complications support stapedotomy, without a laser but with resident involvement, as a highly effective treatment for otosclerosis.  相似文献   

20.
Otosclerosis causes the fixation of the stapes and conductive hearing loss, usually corrected with the use of hearing aids or through stapedotomy and the replacement of the involved stapes with a prosthesis. Titanium has been the most recently used material of choice in stapedotomy prostheses. Only two prostheses are commercially available in Brazil. There are no reports in the literature on the Fisch-type Storz titanium stapes piston prosthesis.ObjectiveThis retrospective study aims to look into the auditory outcomes of patients submitted to stapedotomy and titanium stapes piston prosthesis implantation.MethodThe criteria described by the American Academy of Otolaryngology were used to compare pre and postoperative air-bone gaps seen in audiometry tests.ResultsThe mean low-frequency postoperative air-bone gap was 12.9 dB; the mean high-frequency air-bone gap was 5.2 dB (mean 9.1 dB); median gap was 8.8 dB, with a minimum of 1.3 dB and a maximum of 21.6 dB; standard deviation was 5.7 dB, and p < 0.001. Twenty-five (75.8%) patients had air-bone gaps of 10 dB and under; 32 (96.9%) patients had gaps of 20 dB and under; and all patients had gaps of 30 dB and under.ConclusionThe Fisch-type titanium stapes piston prosthesis presented outcomes consistent with the literature and can be used safely in stapedotomy procedures.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号