首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
BACKGROUND: We hypothesized that the Minimally Invasive Surgery Trainer (MIST-VR; VP Medical R, London, U.K.) would be as effective as the Yale Laparoscopic Skills Course in improving laparoscopic intracorporeal suturing skills. MATERIALS AND METHODS: Each student made six attempts to tie a knot laparoscopically. Students were then randomized to train on the MIST-VR for five sessions (six skills/session) or the Yale Skills for five sessions (three skills/session) over 5 days. On completion of training, all students were evaluated by a test consisting of six attempts to tie a laparoscopic knot. RESULTS: The percentage improvement in knot tying time did not differ significantly in the pelvic trainer group (30 +/- 21%) (from 443 +/- 135 to 311 +/- 137 seconds) and the MIST-VR group (39 +/- 21%) (from 409 +/- 109 to 256 +/- 140 seconds) (P = 0.308). CONCLUSIONS: The MIST-VR is equivalent to the Yale Skills Course for training in the advanced laparoscopic skill of intracorporeal suturing.  相似文献   

2.
BACKGROUND: Advanced surgical skills such as laparoscopic suturing are difficult to learn in an operating room environment. The use of simulation within a defined skills-training curriculum is attractive for instructor, trainee, and patient. This study examined the impact of a curriculum-based approach to laparoscopic suturing and knot tying. STUDY DESIGN: Senior surgery residents in a university-based general surgery residency program were prospectively enrolled and randomized to receive either a simulation-based laparoscopic suturing curriculum (TR group, n=11) or standard clinical training (NR group, n=11). During a laparoscopic Nissen fundoplication, placement of two consecutive intracorporeally knotted sutures was video recorded for analysis. Operative performance was assessed by two reviewers blinded to subject training status using a validated, error-based system to an interrater agreement of >or=80%. Performance measures assessed were time, errors, and needle manipulations, and comparisons between groups were made using an unpaired t-test. RESULTS: Compared with NR subjects, TR subjects performed significantly faster (total time, 526+/-189 seconds versus 790+/-171 seconds; p < 0.004), made significantly fewer errors (total errors, 25.6+/-9.3 versus 37.1+/-10.2; p < 0.01), and had 35% fewer excess needle manipulations (18.5+/-10.5 versus 27.3+/-8.6; p < 0.05). CONCLUSIONS: Subjects who receive simulation-based training demonstrate superior intraoperative performance of a highly complex surgical skill. Integration of such skills training should become standard in a surgical residency's skills curriculum.  相似文献   

3.
BackgroundFew if any medical schools have a comprehensive surgical skills program taking medical students from learning basic knot tying and surgical skills to performing these skills at a level adequate for function during a primary care, surgical, or subspecialty residency. We have designed and continue to refine a program, which consists of five workshops focused on basic surgical skills, which are applicable to all medical and surgical disciplines.Materials and methodsDuring the first workshop students learn how to tie both one- and two-handed surgical knots. The second workshop involves teaching students differences in suture type and use, instrument handling, and suturing techniques. The third workshop is used to address problems and refine techniques previously learned in the first two sessions. The fourth workshop comprises a final examination to evaluate suture and knot tying skills. The fifth session is a voluntary knot tying and suturing competition with awards for speed, finesse, aesthetics, and the watertightness of a vascular surgical repair. Surgical faculty and house staff are present at each workshop to provide direction and constructive criticism.ResultsFifty-seven third-year medical students have completed the surgical skills curriculum. Statistical analysis demonstrates significant improvement in both knot tying and suturing (P < 0.05) for these students. Forty-four percent of students have successfully sewn a watertight anastomosis.ConclusionWe hypothesize that this curriculum will produce medical students with basic surgical skills, appreciation of surgical technique, and the confidence to perform basic surgical skills at completion of the curriculum.  相似文献   

4.
Laparoscopic suturing evaluation among surgical residents   总被引:4,自引:0,他引:4  
BACKGROUND: Laparoscopic suturing is an integral part of advanced laparoscopic surgery training. The objective of this study was to evaluate the performance and preference of surgical residents performing intracorporeal and extracorporeal knot-tying techniques using conventional and Endo Stitch instruments. The residents were also evaluated on their suturing techniques using conventional instruments, the Endo Stitch, and the Suture Assistant. METHODS: Using an inanimate laparoscopic trainer model, 39 residents were evaluated as they performed laparoscopic knot tying exercises. Endpoints of the study were execution time and subjective preference of surgical residents with respect to the type of instrument used for knot tying. Forty-three residents were evaluated as they performed laparoscopic suturing exercises with three different types of suturing instruments using the same endpoints. RESULTS: The intracorporeal technique was the preferred (89%) method of knot tying among surgical residents. The time for completion of laparoscopic suturing was significantly (P < 0.05) shorter with the Endo Stitch (114 +/- 64 s) than with the conventional instrument (206 +/- 107 s) or the Suture Assistant (151 +/- 70 s). Residents preferred the use of the Endo Stitch in all three categories for suturing, knot tying, and handling. CONCLUSION: The Endo Stitch enhanced laparoscopic skills and was the preferred instrument for laparoscopic knot tying and suturing among surgical residents.  相似文献   

5.
BACKGROUND AND PURPOSE: Laparoscopic intracorporeal knot tying in minimally invasive surgery is an advanced skill. Mastering this skill is an arduous process with a long learning curve. While recent advances in instrumentation have allowed easier suturing and tying, until now, no attempts have been made to modify the suture material in order to facilitate this process. We present an evaluation of a novel modified suture material designed to allow inexperienced surgical residents to tie intracorporeal knots laparoscopically using conventional laparoscopic needle drivers. SUBJECTS AND METHODS: Surgical residents with no prior experience in laparoscopic surgery were invited to take part in this investigation. Each of the 14 participants was given a 10-minute demonstration of laparoscopic intracorporeal knot tying and then allowed a mentored practice session of 10 minutes. In the first trial, they were then randomized to tie a laparoscopic knot with either a standard or a modified dry suture. Time and accuracy scores were recorded. They then performed the same task with the other type of suture. On the second trial, wet standard and modified sutures were used, and the order of the sutures used in the first trial was reversed. RESULTS: The average time taken to tie an intracorporeal knot laparoscopically was significantly less when the modified suture was used in both dry and wet conditions (162.71 +/- 10.79 seconds v 270.86 +/- 22.76 seconds; P = 0.0039, and 123.29 +/- 4.70 seconds v 247.57 +/- 23.17 seconds; P = 0.0032, respectively). No significant difference in accuracy scores was noted with the two sutures. CONCLUSIONS: Our modified suture design allowed inexperienced surgical residents to perform intracorporeal laparoscopic knot tying on average faster than the standard suture did. The concept of modifying suture design to facilitate laparoscopic suturing and knot tying deserves further investigation and development.  相似文献   

6.
BACKGROUND: Suturing and knot tying are basic skills for surgeons. Performing these tasks laparoscopically can be a tedious, time-consuming endeavor associated with much frustration. We evaluated a mechanically assisted suture and pretied knot device (Quik-Stitch) for performing the basic tasks of suturing and knot tying. METHODS: We performed a time study using 1) intracorporeal suturing and knot tying, 2) intracorporeal suturing and extracorporeal knot tying, and 3) a mechanically assisted suture and pretied knot device (Quik-Stitch). From September 2000 through March 2001, time trials were conducted using each of the different techniques. Three attending surgeons, one with much experience and 2 with less experience, and 2 chief residents, with the least experience, participated in the study. RESULTS: For the experienced surgeon, the average times for intracorporeal knot tying, extracorporeal knot tying, and knot tying with Quik-Stitch were 97.3, 103.9, and 67.7 seconds, respectively. For the less experienced surgeons, the times were 237.2, 224.3, and 92.5 seconds, respectively. For the least experienced group, the times were 265.3, 263.0, and 128.7 seconds, respectively. CONCLUSIONS: The mechanically assisted suture device and pretied knot (Quik-Stitch by PARE Surgical, Inc, Englewood, CO, USA) provides significant time-saving to surgeons regardless of experience and thus reduces operating room costs. Less experienced surgeons and surgeons in training benefited the most by the use of this device.  相似文献   

7.
This paper reviews the laboratory models used to teach fundamental surgical skills in our general surgery residency. The laboratory modules allow supervision and self-instruction, practice, and videotape monitoring of the following techniques: skin incision, suturing, knot tying, hemostasis, vascular anastomosis, and intestinal anastomosis. Pigs' feet simulate human skin for exercises in skin incision, lesion excision, suturing, and basic plastic surgical techniques. Latex tubing and penrose drains allow experience in suturing, knot tying, and hemostasis. Polytetrafluoroethylene vascular prostheses permit quantification of the precision of needle passage and suturing by measurement of leakage of water through a vascular anastomosis. Reconstituted, lyophilized, irradiated bovine arteries and ileum provide models of biologic tissue for creating handsewn vascular anastomoses and sutured or stapled gastrointestinal anastomoses. A headlamp videocamera allows unobstructive recording of the resident's technical performance and provides subsequent visual feedback for self-improvement when compared to reference instructional videotapes. We feel that these innovations may enhance surgical dexterity of residents without the need for animal sacrifice. Our goal is to foreshorten the learning curve for basic surgical skills and improve performance in the clinical operating room.  相似文献   

8.

Background and Objectives:

Robot-assisted laparoscopic surgery is often taught with the surgical mentor at the surgeon console and the trainee at the patient''s bedside. The da Vinci dual console (Intuitive Surgical, Sunnyvale, California) allows a surgical mentor to teach with both the mentor and the trainee working at a surgeon console simultaneously. The purpose of this study is to evaluate the effectiveness of the dual console versus the single console for teaching medical students robotic tasks.

Methods:

Forty novice medical students were randomized to either the da Vinci single-console or dual-console group and were taught 4 knot-tying techniques by a surgical mentor. The students were timed while performing the tasks.

Results:

No statistically significant differences in mean task times were observed between the single- and dual-console groups: interrupted stitch with a 2-handed knot (300 seconds for single vs 294 seconds for dual, P = .59), interrupted stitch with a 1-handed knot (198 seconds for single vs 212 seconds for dual, P = .88), figure-of-8 stitch with a 2-handed knot (261 seconds for single vs 219 seconds for dual, P = .20), and figure-of-8 stitch with a 1-handed knot (200 seconds for single vs 199 seconds for dual, P = .53).

Conclusion:

No significant difference was observed in performance time when teaching knot-tying techniques to medical students using the da Vinci dual console compared with the single console. More research needs to be performed on the utility of the da Vinci dual console in surgical training.  相似文献   

9.
BACKGROUND: Recent studies comparing inexpensive low-fidelity box trainers to expensive computer-based virtual reality systems demonstrate similar acquisition of surgical skills and transferability to the clinical setting. With new mandates emerging that all surgical residency programs have access to a surgical skills laboratory, we describe our cost-effective approach to teaching basic and advanced open and laparoscopic skills utilizing inexpensive bench models, box trainers, and animate models. METHODS: Open models (basic skills, bowel anastomosis, vascular anastomosis, trauma skills) and laparoscopic models (basic skills, cholecystectomy, Nissen fundoplication, suturing and knot tying, advanced in vivo skills) are constructed using a combination of materials found in our surgical research laboratories, retail stores, or donated by industry. Expired surgical materials are obtained from our hospital operating room and animal organs from food-processing plants. In vivo models are performed in an approved research facility. Operation, maintenance, and administration of the surgical skills laboratory are coordinated by a salaried manager, and instruction is the responsibility of all surgical faculty from our institution. RESULTS: Overall, the cost analyses of our initial startup costs and operational expenditures over a 3-year period revealed a progressive decrease in yearly cost per resident (2002-2003, $1,151; 2003-2004, $1,049; and 2004-2005, $982). CONCLUSIONS: Our approach to surgical skills education can serve as a template for any surgery program with limited financial resources.  相似文献   

10.
Robotic surgery and resident training   总被引:2,自引:0,他引:2  
BACKGROUND: Robotic technology promises to have an important future in surgery, but few residency programs incorporate robotics into surgical training. We sought to compare the speed and accuracy with which junior residents could perform laparoscopic tasks using both a robotic surgical device (Zeus MicroWrist) and conventional laparoscopic instruments. METHODS: Twelve residents performed exercises of progressive difficulty in an inanimate model using both the robot and conventional laparoscopy. Analysis of variance statistical analysis was used to compare task time and suturing accuracy scores. RESULTS: Grasping and suturing exercises were performed significantly faster with conventional laparoscopic instruments than with the robot. However, no difference in task time was noted for intracorporeal knot tying. Accuracy scores for suturing were higher for the robot. CONCLUSIONS: Junior residents can be instructed easily and quickly in both robotic and conventional advanced laparoscopic skills. The utility of robotic surgical devices in resident training requires further investigation.  相似文献   

11.
BACKGROUND: Laparoscopic suturing and tying constitute advanced minimally invasive surgery skills. Developing proficiency in the standard methods with needle drivers is often an arduous process. Recent advances in laparoscopic instrumentations has allowed for easier methods of suturing and tying. This study investigated the hypothesis that the use of a specialized suturing device and a specialized tying device allows inexperienced medical students to suture and tie laparoscopically. METHODS: Preclinical medical students who had not received any training in open or laparoscopic surgery were included in this investigation. Each student was given a 5-minute demonstration of a specialized suturing device and a specialized tying device. The medical students were not allowed to deploy either device before actual use. After the demonstration, each student was given the device to use in a porcine model. Times were recorded and a subjective grade was given for each student. RESULTS: Twenty medical students were involved in this study. All medical students were able to complete the task of suturing and tying. The average time to suture was 104.6 seconds and the average time to tying was 31.2 seconds. The average subjective performance grade was 90 (out of 100). CONCLUSION: Specialized devices are easy to learn and use for laparoscopic suturing and tying with minimal instruction even for inexperienced medical students. Even surgeons who are not well versed in laparoscopic surgery should be able to suture and tie with certain laparoscopic instruments.  相似文献   

12.
BACKGROUND: Proficiency-based training in laparoscopic suturing and knot tying translates to the operating room, but little is known about the durability of acquired skill. The purpose of this study was to determine the effect of maintenance training on skill retention after demonstration of proficiency. STUDY DESIGN: Medical students (n=18) with no previous laparoscopic or simulator experience were enrolled in an IRB-approved randomized controlled trial. All subjects trained to proficiency (score of 512, based on time and errors) on a previously validated suturing model (Fundamentals of Laparoscopic Surgery videotrainer). Subjects were then randomized to a control group, which received no additional training, and an ongoing training group, which trained again to proficiency at 1 and 3 months (immediately after testing). Simulator testing was repeated at 2 weeks, 1 month, 3 months, and 6 months after initial training. No subject had interval operative experience. RESULTS: Both groups demonstrated excellent skill retention during followup; performance scores, reported as means+/-SD, were 488+/-57 versus 482+/-55 at 2 weeks (p=ns), 483+/-81 versus 491+/-64 at 1 month (p=ns), 467+/-75 versus 470+/-67 at 3 months (p=ns), and 462+/-62 versus 492+/-43 at 6 months (p=0.02) for the control versus ongoing training groups, respectively. At 6 months, the ongoing training group showed better skill retention (95% versus 90%; p=0.02) and a trend for achieving the proficiency level (33% versus 18%; p=0.2) more often than the control group. CONCLUSIONS: Although proficiency-based training results in excellent skill retention, ongoing training substantially enhances performance and minimizes skill loss. Curricula should incorporate training that fosters maintenance of proficiency.  相似文献   

13.

Background

Intracorporeal suturing and knot tying (ICKT) in minimal invasive surgery (MIS) represents a key skill for advanced procedures. Different methods exist for measuring knot quality and performance, but the heterogeneity of these methods makes direct comparisons difficult. The aim of this study is to compare the quality of a laparoscopic knot to one that is performed open.

Methods

To compare open and laparoscopic knot-tying methods we used a surgeon's square knot. For laparoscopic knot tying we used a Pelvitrainer. The 32 participants were divided among 4 groups of different skill levels. Group 1 consisted of 6 senior physicians. Group 2 was made up of 10 first to fourth year interns. Groups 3 and 4 contained 16 medical students who had never performed either laparoscopic procedures or open sutures before. Group 3 participants received a 1-hour hands-on training in suturing, whereas group 4 participants received no prior training. Total time, knot quality, suture placement accuracy, and performance defined the parameters for assessment in this study.

Results

All participants, irrespective of education level were inferior in ICKT compared to open suturing. Only Group 1 showed no significant difference in knot quality and accuracy between the open and laparoscopic suture performance.

Conclusion

It is well documented that psychomotor skills need to be developed before more advanced skills can be put into practice. Training centres for minimally invasive surgery should be an integral part of surgical education. The variables in our study are meaningful and easy to implement. They can be used to measure personal progress and as objective parameters in the development of laparoscopic trainee education.  相似文献   

14.
INTRODUCTION: The ability to mentally rotate an object in 3 dimensions has been shown with an individual's score on the Vandenberg and Kuse Mental Rotations Test. The was to determine whether this Mental Rotations Test could be used to predict performance complex surgical skill - the tying of a 1-handed surgical reef knot. In addition, we learning a spatially complex surgical skill could be achieved more effectively via a computer-based selfdirected learning approach than with a didactic lecture-based teaching method. METHODS: preclerkship medical students at the University of Western Ontario were randomized into computer-based self-directed learning group and a didactic lecture-style learning group. administration of the Mental Rotations Test, the students were taught how to tie a reef knot via the learning modality assigned to their respective group. RESULTS: Students Mental Rotations Test scores were able to tie more surgical knots in the allocated time Students learning how to tie the surgical knot via the computer-based self-directed showed improvement on their knot tying abilities more rapidly than their didactically trained colleagues. CONCLUSION: The ability to mentally rotate an object in 3 dimensions played an important initial learning of a spatially complex surgical technical skill. Our data demonstrated learning was as effective and more practical than traditional lecture-based learning.  相似文献   

15.

Background

Three-dimensional (3D) surgical imaging systems provide stereoscopic depth cues that are lost in conventional two-dimensional (2D) display systems. Recent improvements in stereoscopic projection technology using passive polarising displays may improve performance of minimally invasive surgical skills. This study aims to identify the effect of passive polarising stereoscopic displays on novice surgeon performance of minimally invasive surgical skills.

Methods

20 novice surgeons performed 10 repetitions of 4 surgical skills tasks using a new passive polarising stereoscopic display under 3D and 2D conditions. The previously validated tasks used were rope pass, paper cut, needle capping and knot tying. Outcome measures included total error rate and time for task completion.

Results

Novice surgeons demonstrated a significant reduction in error rates for sequential repetitions of each task using the passive polarising stereoscopic display compared with the 2D display. Mean errors for the 3D versus the 2D mode were 2.0 versus 4.3 for rope pass (P?≤?0.001), 0.8 versus 1.6 for paper cut (P?=?0.001), 1.3 versus 4.2 for needle capping (P?≤?0.001) and 2.8 versus 8.0 for knot tying (P?≤?0.001). Novice surgeons demonstrated a significant improvement in mean time for completion for all four tasks when using the 3D system. Mean time (in seconds) for 3D versus 2D were 106.5 versus 134.4 for rope pass (P?≤?0.001), 116.1 versus 176.3 for paper cut (P?≤?0.001), 76.3 versus 141.6 for needle capping (P?≤?0.001) and 153.4 versus 252.6 for knot tying (P?≤?0.001).

Conclusion

Passive polarising stereoscopic displays significantly improve novice surgeon performance during acquisition of minimally invasive surgical skills.  相似文献   

16.
Enabling trainees to acquire advanced technical skills before they begin the operating room experience benefits both trainee and patient. Whether medical students who had received exclusively simulation-based training could perform laparoscopic suturing and knot-tying as well as senior surgery residents was determined. Simulators were used to train 11 fourth-year medical students with no previous suturing experience to perform intracorporeal suturing and to successfully tie a free-hand intracorporeal knot. Students' skills were assessed by the performance of the fundal suturing portion of a Nissen fundoplication in a porcine model. Their operative performance was evaluated for time, needle manipulations, and total errors. Results were compared to those of 11 senior-level surgery residents performing the same task. The study concluded that trainees could learn advanced technical skills such as laparoscopic suturing and knot tying by using simulation exclusively. The trainees and senior level surgery residents had a similar number of needle manipulations.  相似文献   

17.
PURPOSE: The study aim was to demonstrate that a new database tool for assessment of surgical resident operative skills discerns predictable progression in those skills over successive residency years for specific index case types. METHODS: A Web-based interactive database (OpRate) was used to assess selected aspects of resident operative performance as determined by supervising attending surgeons in a medium-sized residency (5-6 residents per postgraduate year [PGY]). This assessment consisted of (1) 3 questions pertaining to patient information, technical, and disease-specific preparedness; (2) 4 laparoscopic technical skills questions pertaining to tissue handling, dexterity, planning, and ability to function independently; and (3) similar open technical skills questions, with the addition of 2 questions defining knot tying ability. Two years of assessment data were examined for cholecystectomy (CH), appendectomy (AP), colon resection (CR), ventral hernia repair (VH), and inguinal hernia repair (IH). Mean scores for total, technical, and preparedness responses, as well as each response area were compared for successive training years for each case type. Mean performance data between postgraduate years were compared by ANOVA, and interitem reliability was assessed by Cronbach's alpha determinations. RESULTS: OpRate data for 579 cases (142 CH, 67 AP, 73 CR, 202 IH, and 95 VH) were examined. Significant incremental increases in open and laparoscopic technical skills scores by training year were observed for all case types (ANOVA, p < 0.0001). Individual technical skills as well as technical and disease-specific preparedness response areas also demonstrated significant improvement by successive training year. Cronbach's alpha determinations were 0.80-0.94 for the preparedness test items and the skills performance scores for all assessed procedures. CONCLUSIONS: Our early results show that the OpRate assessment tool is effective in identifying expected changes in operative performance across successive training years, with a satisfactory level of internal consistency for the test items. As such, the use of this database tool may offer the opportunity to (1) define performance benchmarks for specific levels of training and (2) identify areas where focused training may be required for specific residents.  相似文献   

18.
Teaching basic video skills as an aid in laparoscopic suturing   总被引:3,自引:3,他引:0  
Background There is a perception among surgeons that performing laparoscopic suturing is unduly difficult. The purpose of this study is to document a program which aides in learning laparoscopic suturing. Methods Fourteen volunteer medical students without prior experience were taught laparoscopic suturing. Videoscopic pelvitrainers were utilized for a 2-h training session. Extracorporeal and intracorporeal knot tying was demonstrated utilizing a three-throw square knot. After a 2-h practice session each student’s time to complete an extracorporeal and intracorporeal suture was recorded. Results The average times required for completion were: extracorporeal suture and knot 1 min 54 s; intracorporeal suture and knot 3 min 12 s. Conclusions Novice students were able to perform at extra and intracorporeal suturing with 2 h of practice, utilizing a systematic program of teaching basic video skills. Presented at the annual meeting of the Society of American Gastrointestinal Endoscopic Surgeons (SAGES), Orlando, Florida, USA, 11–14 March 1995  相似文献   

19.
BACKGROUND: The study aim was to compare the effectiveness of virtual reality and computer-enhanced videoscopic training devices for training novice surgeons in complex laparoscopic skills. METHODS: Third-year medical students received instruction on laparoscopic intracorporeal suturing and knot tying and then underwent a pretraining assessment of the task using a live porcine model. Students were then randomized to objectives-based training on either the virtual reality (n=8) or computer-enhanced (n=8) training devices for 4 weeks, after which the assessment was repeated. RESULTS: Posttraining performance had improved compared with pretraining performance in both task completion rate (94% versus 18%; P<0.001*) and time [181+/-58 (SD) versus 292+/-24*]. Performance of the 2 groups was comparable before and after training. Of the subjects, 88% thought that haptic cues were important in simulators. Both groups agreed that their respective training systems were effective teaching tools, but computer-enhanced device trainees were more likely to rate their training as representative of reality (P<0.01). CONCLUSIONS: Training on virtual reality and computer-enhanced devices had equivalent effects on skills improvement in novices. Despite the perception that haptic feedback is important in laparoscopic simulation training, its absence in the virtual reality device did not impede acquisition of skill.  相似文献   

20.
BACKGROUND: There is a need for reliable and valid objective methods of technical skills in surgery. Six-bench surgical top stations have been combined to assess basic surgical trainees (BSTs) objectively. The current study examines its reliability and validity across repeat sittings. METHODS: Eleven surgical trainees (6 senior BSTs and 5 higher surgical trainees [HSTs]) undertook 5 sittings of the 6-station assessment designed to be completed within 90 minutes. The 6 stations consisted of knot tying, suturing, closure of enterotomy, excision of sebaceous cyst, laparoscopic task, and instrument examination. Methods of analysis employed were motion analysis, observation with criteria, and inbuilt simulation metrics. RESULTS: On analysis 3 knot tying and suturing stations exhibited significant differences in either time or movement; any difference was over by the second run. The intertest reliabilities were .66, .74, .55, .51, and .65 for the 5 runs. The intratest reliability across repeated sittings varied from .56 to .96. The inter-rater reliability for video assessment varied from .77 to .94. CONCLUSION: The assessment is reliable and valid across repeated sittings. Its use in assessment of basic technical skills needs to be encouraged.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号