首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Although few reports address the use of three-phase bone scanning (TPBS) and 111In-labeled white blood cell (In-WBC) scintigraphy in hip arthroplasty utilizing a porous coated prosthesis, the literature suggests that scintigraphic patterns in the uncomplicated patient may differ from that seen in the cemented prosthesis. In an attempt to determine the scintigraphic natural history, 25 uncomplicated porous coated hip arthroplasties in 21 patients were prospectively studied with serial TPBS and In-WBC at approximately 7 days, and at 3, 6, 12, 18, and 24 mo postoperatively. This report deals with findings related to the prosthetic tip. Only one of 136 flow studies were abnormal and only two of 136 blood-pool images demonstrated focally increased activity. All 25 prostheses (120 of 143 scans) demonstrated increased uptake on the bone phase images. The area about the tip was divided into three segments; increased uptake at 24 mo was noted in the medial, distal, and lateral segments in 16%, 72%, and 56% of prostheses, respectively. Twenty of 25 prostheses (82 of 142 scans) showed uptake on In-WBC scintigraphy, being noted in 48% of prostheses at 24 mo. We conclude that scintigraphic patterns in the uncomplicated patient with a porous coated prosthesis appear to differ from patterns described in cemented prostheses.  相似文献   

2.
Patients with problems following implantation of cemented total hip prostheses must be clinically examined. This examination is followed by a series of diagnostic imaging procedures. These include X-ray diagnosis, 3-phase 99mTc-MDP bone scans, scintigraphy for inflammation, and arthrography, performed singly or as sequential studies. X-ray findings and scintigraphic patterns arousing or confirming a suspicion of aseptic (mechanical) or septic (infectious) loosening of the prosthesis are evaluated and discussed.  相似文献   

3.
The evaluation of a painful hip prosthesis for suspected loosening frequently requires a multi-modality approach. Radionuclide arthroscintigraphy is a valuable adjunct to contrast arthrography, demonstrating greater sensitivity than contrast arthrography in detecting loosening of the femoral component of the prosthesis. Despite its reliability in the evaluation of cemented hip prostheses, the value of arthroscintigraphy in patients with uncemented or porous-coated prostheses is undetermined. The case of a false-positive radionuclide arthroscintigram in a patient with an uncemented prosthesis is reported. The literature is briefly examined, and the potential implications regarding interpretation of arthroscintigraphy in patients with porous-coated prostheses are discussed.  相似文献   

4.
We have used 99Tcm-labelled nanocolloid in an attempt to locate areas of inflamed bowel wall or abscesses in five patients with ulcerative colitis and nine with Crohn's disease. The scintigraphic findings were evaluated by comparison with those of recent barium studies and, in three patients, with surgical findings at laparotomy. It proved difficult to localize segments of inflamed bowel accurately with 99Tcm-nanocolloid because of the accumulation of radioactivity in the gut lumen, especially 2 or more hours after injection. However, there was little uptake of the labelled nanocolloid by areas of inflamed gut wall in the period before 2 h. When 99Tcm-nanocolloid scans were compared with 111In-WBC scans in eight patients who had both investigations, 99Tcm-nanocolloid scintigraphy was considerably less sensitive than 111In-WBC scintigraphy. One abscess was located correctly; the other was obscured by nearby bladder and bone marrow radioactivity. We conclude that 99Tcm-nanocolloid scanning is neither sensitive nor reliable enough for assessing the location of inflamed bowel wall or the presence of abscess in patients with inflammatory bowel disease.  相似文献   

5.
Hip arthroplasty is a common surgical procedure, but the diagnosis of infection associated with hip arthroplasty remains challenging. Fluorine-18 fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) has been shown to be a promising imaging modality in settings where infection is suspected. However, inflammatory reaction to surgery can result in increased FDG uptake at various anatomic locations, which may erroneously be interpreted as sites of infection. The purpose of this study was to assess the patterns and time course of FDG accumulation following total hip replacement over an extended period of time. Firstly, in a prospective study nine patients with total hip replacement were investigated to determine the patterns of FDG uptake over time. Three FDG-PET scans were performed in each patient at about 3, 6 and 12 months post arthroplasty. Secondly, in a retrospective analysis, the medical and surgical history and FDG-PET imaging results of 710 patients who had undergone whole-body scans for the evaluation of possible malignant disorders were reviewed. The history of arthroplasty and FDG-PET findings in the hip region were reviewed for this study. Patients with symptomatic arthroplasties or related complaints during FDG-PET scanning were excluded from the analysis. During the entire study period, all nine patients enrolled in the prospective study were demonstrated to have increased FDG uptake around the femoral head or neck portion of the prosthesis that extended to the soft tissues surrounding the femur. Among the patients reviewed in the retrospective study, 18 patients with a history of 21 hip arthroplasties who were asymptomatic at the time of FDG-PET scan met the criteria for inclusion. The time interval between the hip arthroplasty and the FDG-PET study ranged from 3 months to 288 months (mean+/-SD: 80.4+/-86.2 months). In 81% (17 of 21) of these prostheses, increased FDG uptake could be noted around the femoral head or neck portion of the prosthesis. The average time interval between arthroplasty and FDG-PET scan in these patients was 71.3 months. In only four prostheses (19%, 4 of 21) was no abnormally increased FDG uptake seen around the prostheses or adjacent sites. The average time interval in these patients was 114.8 months. It is concluded that following hip arthroplasty, non-specifically increased FDG uptake around the head or neck of the prosthesis persists for many years, even in patients without any complications. Therefore, to minimize the number of false-positive results for infection with PET studies obtained to evaluate a painful hip prosthesis, caution should be exercised when interpreting FDG uptake around the head or neck portion of the prosthesis.  相似文献   

6.
Polyethyleneglycol (PEG) liposomes have been shown to be excellent vehicles for scintigraphic imaging of infection and inflammation in various experimental models. In this article we report on a series of patients with possible infectious and inflammatory disease in whom the performance of 99mTc-PEG liposomes was evaluated. The results of 99mTc-PEG liposome scintigraphy were directly compared with those of 111In-immunoglobulin G (IgG) scintigraphy. METHODS: Thirty-five patients (22 men, 13 women; mean age, 51 y; range, 20-76 y), suspected of having infectious or inflammatory disease, received 740 MBq 99mTc-PEG liposomes intravenously. Imaging was performed at 4 and 24 h after injection. Patients received 75 MBq 111In-IgG 24 h after administration of the liposomes. The scintigraphic results were compared and verified by culture, biopsy, surgery, and follow-up of at least 6 mo. RESULTS: Of the 16 proven infections and inflammations, 15 were detected by 99mTc-PEG liposome scintigraphy: soft-tissue infection (n = 3), septic arthritis (n = 3), autoimmune polyarthritis (n = 2), infected hip prosthesis (n = 1), infected osteosynthesis (n = 1), spondylodiscitis (n = 1), infected aortic prosthesis (n = 1), colitis (n = 1), abdominal abscess (n = 1), and pneumonia (n = 1). 99mTc-PEG liposome and 111In-IgG scintigraphy both missed 1 case of endocarditis. In addition, an 111In-IgG scan of a patient with mild soft-tissue infection was false-negative. Concordantly false-positive scans were recorded from 2 patients, both with uninfected pseudarthrosis and focal signs of sterile inflammation. During liposomal administration, 1 patient experienced flushing and chest tightness, which rapidly disappeared after lowering the infusion rate. No other adverse events were observed. CONCLUSION: This clinical evaluation of 99mTc-PEG liposomes shows that focal infection and inflammation can be adequately imaged with this new agent. The performance of 99mTc-PEG liposomes is at least as effective as that of 111In-IgG. With the simple and safe preparation and the physical and logistic advantages of a 99mTc label, 99mTc-PEG liposomes could be an attractive agent for infection or inflammation imaging.  相似文献   

7.
Indium-111-leukocyte imaging in acute cholecystitis   总被引:1,自引:0,他引:1  
Eleven patients with suspected acute cholecystitis underwent sequential 99mTc-iminodiacetic derivative (IDA) and 111In-white blood cell (WBC) imaging to determine if 111In-WBCs accumulate within an acutely inflamed hemorrhagic gallbladder wall and, thus, could be employed as a reasonable alternative to 99mTc-IDA scintigraphy in detecting acute cholecystitis. Seven patients had surgically confirmed acute cholecystitis. Of these cases, five had a true-positive 99mTc-IDA and 111In-WBC, one an indeterminate 111In-WBC and true-positive 99mTc-IDA, and one a true-positive 111In-WBC and false-negative 99mTc-IDA scan. The remaining four patients did not have acute cholecystitis. All visualized their gallbladder within 1 hr after 99mTc-IDA administration and none had 111In-WBC gallbladder wall uptake. Both 111In-WBC and 99mTc-IDA scintigraphy accurately detected acute cholecystitis: hepatobiliary scintigraphy demonstrated a cystic duct obstruction and 111In-WBC imaging detected the inflammatory infiltrate within the gallbladder wall. The sensitivity and specificity of each was 86% and 100%, respectively.  相似文献   

8.
AIM: To evaluate clinical efficacy of a dual-time acquisition protocol, which included 4 and 20/24-h imaging with antigranulocyte antibody scintigraphy (LeukoScan) combined with semiquantitative analysis in the diagnosis of infection in painful hip prosthesis. METHODS: Sixty-seven consecutive patients with hip prosthesis were enrolled in this research project: 35 females, 32 males, mean age of 56.3 years. All patients had clinical and biochemical suspicious of infection. Each prosthesis had been implanted 3 months to 12 years before enrollment in this study. Twenty-four patients were on antibiotic therapy at the time of scintigraphy. Seven patients had bilateral hip prosthesis, one painful and the other painless: the seven painless prostheses were considered controls. LeukoScan examination was performed both at early (4 h) and delayed (20/24 h) times. The scintigraphic data were assessed both by visual and semiquantitative methods by three experienced nuclear medicine physicians blinded to clinical, laboratory and radiographic results. The uptake was graded visually by a 4-point scale: intense=3, moderate=2, mild=1 and absent=0. The semiquantitative analysis was obtained by a region of interest (ROI) analysis used in the anterior views to measure the ratio between the mean radioactivity in the prosthesis and the background radioactivity in the early and delayed images. An increase in the intensity of uptake of at least one scale-step at visual analysis and 20% at semiquantitative ROI analysis at the dual-time (early vs. delayed) LeukoScan was considered consistent with infection, whereas a stable or decreasing pattern was judged a negative result. Three-phase 99mTc-hydroxymethane diphosphonate bone scan was also performed routinely. Final diagnosis was determined at surgery and/or long-term clinical and imaging follow-up. RESULTS: At visual analysis, sensitivity for both early and delayed imaging was 94%, whereas specificity was 71% for early imaging and 83% for early and delayed imaging approach. At semiquantitative ROI analysis, sensitivity remained 94%, whereas specificity rose slightly to 73% for early imaging and to 90% for early and delayed imaging combined. Of note, four false-positive early scans were diagnosed correctly as negative on delayed imaging showing a decreasing pattern in uptake intensity. Sensitivity and specificity were similar whether patients were on or off antibiotic therapy. CONCLUSION: Our data show that early imaging LeukoScan is highly sensitive in evaluating septic prosthesis, but it is not optimally specific. Although the dual-time LeukoScan is capable of significantly increasing specificity for detecting infection. The semiquantitative ROI analysis further increased the specificity. Concomitant antibiotic treatment did not seem to influence the diagnostic efficacy of LeukoScan scintigraphy in detecting infected hip prosthesis.  相似文献   

9.
A unique scintigraphic appearance has been noted in uncomplicated hip prostheses which have the acetabular component inserted after under-reaming or where a cone-shaped cup is inserted. We hypothesized that the pattern of increased uptake around the superior and inferior third of the cup with relatively reduced uptake in the medial third is due to preferential loading of the rim of the cup. A prospective study of ten patients with uncomplicated hip prostheses supports the hypothesis.  相似文献   

10.
Forty-nine patients with 50 fracture nonunions 4-48 months after injury underwent technetium-99m methylene diphosphonate (99mTc-MDP) scintigraphy on day 1, combined 99mTc-MDP and indium-111 leukocyte (111In-WBC) scintigraphy on day 2, and gallium-67 (67Ga) scintigraphy on day 3. The results were compared to evaluate the relative abilities of these scintigraphic techniques to detect osteomyelitis. Nine patients had clinical evidence of infection at the time of imaging, and 40 patients (41 fractures) did not. Open-biopsy cultures were performed at all fracture sites and were positive at 21 (42%) of the 50 sites. Combined 99mTc-MDP/111In-WBC images were interpreted with the use of two criteria. A positive study by the first criterion required 111In-WBC localization in the region of the nonunion fracture. A positive study by the second criterion required 111In-WBC localization in bone at the fracture site. The first criterion yielded a sensitivity of 84%, specificity of 72%, and accuracy of 74%; the specificity improved to 97% with an accuracy of 88% when the second criterion was used. Ten (25%) of the 40 patients thought not to have osteomyelitis by clinical criteria at the time of imaging had true-positive 99mTc-MDP/111In-WBC studies by biopsy culture results. Gallium-67 studies were interpreted as nondiagnostic if localization of radioisotope at fracture sites was equal to that with 99mTc-MDP, positive if 67Ga localization was greater than that of 99mTc-MDP, and negative if it was less than that of 99mTc-MDP. Twenty-one 67Ga studies were interpreted as nondiagnostic; 11 (52%) of the 21 had culture-positive fracture sites. The accuracy of 67Ga/99mTc-MDP imaging was 39%. Combined 99mTc-MDP/111In-WBC imaging is useful in the detection of osteomyelitis at fracture nonunion sites and improves the specificity of 111In-WBC imaging by differentiating inflammation/infection in adjacent soft tissue from osteomyelitis at the fracture site. Gallium-67 with 99mTc-MDP imaging is not sufficiently reliable in this clinical setting to be useful as an indicator for osteomyelitis.  相似文献   

11.
Immunoscintigraphy with the use of the antigranulocyte antibody BW 250/183 is a reliable method for detecting infection, especially in septic loosening of hip prostheses, for which purpose quantitative interpretation of the time-activity course is employed. Therefore, we retrospectively studied whether similar results could be achieved in knee prostheses. We verified 28 scintigraphic examinations in 26 patients by histology. Scintigraphy was performed during an early (4–6 h post injection) and a late phase (23–25 h post injection). Infection was diagnosed when activity around the knee prosthesis increased by more than 10% compared with bone marrow. We found a sensitivity and a negative predictive value of 100%, a specificity of 80%, a positive predictive value of 81% and an accuracy of 89%. Specificity and accuracy are lower than in the evaluation of hip prostheses; however, in comparison to other scintigraphic modalities, scintigraphy with the antigranulocyte antibody BW 250/183 is superior in excluding infection and has better specificity and accuracy. Therefore, as in the case of hip prostheses, the described methodology appears to be the scintigraphic modality of choice for knee prostheses.  相似文献   

12.
Pain is a common unspecific symptom in orthopaedic prosthetics. The accurate differentiation between synovitis, loosening or infection is often difficult with conventional X-rays, arthrography or bone scintigraphy. Because of the high glucose uptake of inflammatory cells, [18F]fluorodeoxyglucose (18F-FDG) is an appropriate tracer for the evaluation of suspected inflammation or infection. In this preliminary study we describe 18F-FDG PET findings in patients referred for evaluation of painful hip or knee prostheses. We studied 23 patients with 28 prostheses, 14 hip and 14 knee prostheses, who had a complete operative or clinical follow-up. 18F-FDG PET scans were obtained with an ECAT EXACT HR+ PET scanner. High glucose uptake in the bone prostheses interface was considered as positive for infection, an intermediate uptake as suspect for loosening, and uptake only in the synovia was considered as synovitis. The imaging results were compared with operative findings or clinical outcome. PET correctly identified three hip and one knee prostheses as infected, two hip and two knee prostheses as loosening, four hip and nine knee prostheses as synovitis, and two hip and one knee prostheses as unsuspected for loosening or infection. In three patients covered with an expander after explantation of an infected prosthesis PET revealed no further evidence of infection in concordance with the clinical follow-up. PET was false negative for loosening in one case. Our preliminary results suggest that FDG PET could be a useful tool for differentiating between infected and loose orthopaedic prostheses as well as for detecting only inflammatory tissue such as synovitis.  相似文献   

13.
Metal-induced artifacts impair image quality of computed tomography (CT) and magnetic resonance imaging (MRI) in patients with hip prostheses. Due to new developments in metal artifact reduction both methods can now be used for evaluation of a painful hip prosthesis. Iterative reconstruction algorithms and dual-energy scans are among the newer CT techniques for artifact reduction, while slice-encoding for metal artifact correction (SEMAC) and multi-acquisition variable-resonance image combination (MAVRIC) have introduced substantial improvements for MRI. Loosening of the hip prosthesis, osteolysis from small wear particles and pseudotumors in metal-on-metal prostheses are specific pathologies in patients with total hip arthroplasty. Other causes of painful hip prostheses are infections, fractures, tendinopathies, tendon ruptures, muscle and nerve alterations and heterotopic ossifications.  相似文献   

14.
Cemented total hip prosthesis: radiographic and scintigraphic evaluation   总被引:1,自引:0,他引:1  
Aliabadi  P; Tumeh  SS; Weissman  BN; McNeil  BJ 《Radiology》1989,173(1):203-206
Conventional radiographs, technetium-99m bone scans, and gallium-67 scans were reviewed in 44 patients who had undergone cemented total hip joint replacement and were imaged because of suspicion of prosthesis loosening or infection. A complete radiolucent line of 2 mm or wider along the bone-cement interface or metal-cement lucency on conventional radiographs was used as the criterion for prosthetic loosening with or without infection and proved to be 54% sensitive and 96% specific. Scintigraphic criteria for prosthetic loosening were increased focal uptake of the radiopharmaceutical for the femoral component and increased focal or diffuse uptake for the acetabular component. For bone scintigraphy, sensitivity was 73% and specificity was 96%. Combining the results of conventional radiographs and bone scans increased sensitivity to 84% and decreased specificity to 92% for the diagnosis of loosening, infection, or both. The study also showed that Ga-67 scintigraphy has a low sensitivity for the detection of infection.  相似文献   

15.
Somatostatin receptor scintigraphy is widely used in the management of neuroendocrine tumors. Somatostatin receptors are present in both neoplastic and normal tissues, which may lead to misinterpretation of the scans. Here, a patient with lung carcinoid imaged with In-111 octreotide is presented. Imaging was performed 4 and 24 hours after an intravenous injection of 185 MBq In-111 octreotide in the post prandial state. Whole body and SPECT images showed accumulation of radioactivity in the gallbladder. Imaging was repeated after fatty meal ingestion to differentiate abnormal activity and physiological uptake in the gallbladder. The abdominal SPECT studies at 28 hours revealed no uptake in the gallbladder, and the scintigraphic study was reported as normal so further excessive diagnostic procedures were prevented. Gallbladder can be visualized on somatostatin receptor scintigraphy even in the post prandial state. Delayed images after fatty meal administration are important for differential diagnosis.  相似文献   

16.
In 35 patients suspected of an infectious focus, the outcome of scintigraphy with 111In-labeled autologous leukocytes (WBC) and 111In-labeled human nonspecific immunoglobulin G (IgG) was evaluated in a prospective comparative study. Clinical, roentgenologic and microbiologic findings were considered to be proof of the presence of infection or inflammation. In this group of patients with mainly subacute infections, 111In-IgG scintigraphy performed significantly better than 111In-WBC scintigraphy, especially in infections of the locomotor system, but also in various soft-tissue infections. Both techniques showed disappointing results in patients with disseminated yersinia infection and in some patients with tuberculosis. Overall sensitivity and specificity was 74% and 100% for 111In-IgG scintigraphy and 52% and 78% for 111In-WBC scintigraphy, respectively.  相似文献   

17.
Radiological evaluation of painful total hip replacement   总被引:3,自引:0,他引:3  
Ninety-four cases of clinically failed, cemented, total hip prostheses requiring surgery were reviewed to determine the accuracy of preoperative plain radiography, culture of aspirated fluid, arthrography, and bone scanning. When radiopaque cement had been used to embed the prosthesis, plain radiography was highly accurate in detecting a loose femoral component, less so in detecting a loose acetabular component. Culture of aspirated fluid was accurate in diagnosing infection. A positive arthrogram identified loosening with good accuracy; however, a negative arthrogram did not reliably exclude loosening. 99mTc bone scans frequently differentiated loosening from loosening with infection. The suggested sequence of diagnostic tests is plain radiography followed by bone scanning. If the bone scan shows diffuse augmented uptake, culture of aspirated fluid followed by arthrography is indicated.  相似文献   

18.
Forty-three patients with suspected infection of a hip or a knee prosthesis were studied with white blood cell scintigraphy (WBC), using technetium-99m (n = 37) or iodine-123 (n = 6) labelled monoclonal mouse antibody (MoAb). Previously, all patients had undergone skeletal scintigraphy, which was performed as a three-phase study in 33 cases. The final diagnosis was established by open surgery, histology and culture in 37 cases, by puncture and culture in 3 cases, and by clinical follow-up of at least 6 months in 3 cases. Eighteen prostheses were infected, 25 uninfected. The delayed phase of skeletal scintigraphy had a sensitivity of 92%, a specificity of 24% and an accuracy of 48% in the detection of infection. The perfusion and blood pool activity of the three-phase bone scan had a sensitivity of 67%, a specificity of 71% and an accuracy of 70%. The diagnostic value of WBC was sensitivity 89%, specificity 84% and accuracy 86%. WBC with 99m-Tc-MoAb is easy to perform and always available. Its diagnostic accuracy is similar to conventional WBC scintigraphy with either indium-111 or technetium-99m.  相似文献   

19.
目的探讨保留股骨颈型人工全髋关节置换的治疗价值。方法2000年9月—2006年12月,我科应用保留股骨颈型人工全髋关节置换治疗髋关节骨关节病25例(30髋),单侧20例,双侧5例。结果本组经过0.5~6年随访,30个人工髋关节临床效果良好。人工髋关节的活动和其后关节功能良好,X线摄片示人工髋关节位置良好,假体无松动和下沉。结论保留股骨颈型人工全髋关节置换符合股骨近端生理顺应性,使假体适应应力分布。防止股骨近端骨质疏松引起假体松动和下沉。同时为今后需要假体翻修提供骨结构基础。  相似文献   

20.
Ten per cent of patients with hip replacement will eventually complain of significant pain after surgery, often requiring a revision arthroplasty. The majority of these patients experience aseptic loosening rather than infection. Despite significant advances made in diagnostic imaging, distinguishing infection from aseptic loosening remains a significant challenge. Imaging using fluorodeoxyglucose (FDG) positron emission tomography (PET) has been reported to have excellent sensitivity in detecting infections associated with hip prostheses. However, in some studies, a high rate of false positive results has been reported, especially when increased tracer uptake adjacent to the prosthesis (which is not surrounded by bone) is used as the sole criterion for diagnosing infection. The objective of this investigation was to determine the optimal criteria for diagnosing periprosthetic infection, thereby avoiding false positive results in this setting. A total of 41 total hip arthroplasties from 32 patients and for whom complete clinical follow-up was available were included in this analysis. The location and intensity of FDG uptake were determined for each scan. Final diagnosis was made by microbiology, histopathology, surgical findings and clinical follow-up. Patients who did not undergo surgery were followed up to at least 9 months. Twelve patients were proven eventually to have periprosthetic infection. Images from 11 of these patients displayed increased tracer uptake along the interface between bone and prosthesis. The intensity of the increased tracer uptake varied from mild to moderate, with standardized uptake values less than 2. In contrast, images from uninfected, loose hip prostheses revealed very intense uptake around the head or neck of the prosthesis with standardized uptake values as high as 7. It is concluded that the intensity of increased FDG uptake is less important than the location of increased FDG uptake when FDG PET is used to diagnose periprosthetic infection in patients with hip arthroplasty. Using increased uptake as the sole criterion for diagnosing infection will result in false positive results in this setting.  相似文献   