相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
This report describes our results with transcatheter closure of patent ductus arteriosus between March 1993 and May 2000 including our early experience with the Amplatzer duct occluder. One hundred and sixty-six consecutive procedures were performed in 160 patients. The mean age was 6.8 years (range 0.8 to 26.2), mean weight 24.3 kg (range 7.7 to 84.0). Single or multiple coils were implanted successfully in 114 cases, a Rashind double umbrella in 35 patients, and an Amplatzer duct occluder in 16 patients. After failure to implant coils in one patient, a second attempt with a Rashkind double umbrella was successful. Complete closure of the patent ductus arteriosus was achieved in a total of 148 patients (92.5%), mean fluoroscopy time was 13.7 min (range 3.1 to 126 min). In 144 patients (90.0%), occlusion without residual shunting was achieved by the first interventional approach. Angiography showed immediate closure in 44%, echocardiography within 48 h revealed complete closure in additional 28%. In a further 18%, a residual shunt disappeared spontaneously in the following months. In five patients a second procedure was performed to terminate residual shunting after placement of a Rashkind occluder system by coils. In three patients, the residual shunt resolved. In 12 patients (7.5%) echocardiography showed a residual shunt 2-1259 days after interventional approach. Occlusion rates of the different devices were 83% for the Rashkind occluder, 92% for detachable coils, and 100% for the Amplatzer duct occluder. Coil embolisation into the pulmonary artery occurred in two patients, interventional removal was successful in one of them. There were no further complications. According to our experience interventional occlusion of patent ductus arteriosus is highly effective and associated with a low complication rate. Transcatheter closure using the Amplatzer duct occluder seems to be safe and effective also in small children with a body weight of 8 kg and a large ductus diameter. Compared to the total group of patients, the occlusion rate of the Amplatzer duct occluder was significantly higher (p = 0.005), and of the Rashkind occluder system significantly lower (p = 0.026). Therefore, we recommend the use of detachable coils in patients with small ductus (diameter < or = 2 mm) and the Amplatzer duct occluder in those with a larger ductus. Transcatheter closure of the patent ductus arteriosus according to this regimen should achieve occlusion rates above 95%.  相似文献   

2.
This study was performed to evaluate the efficacy of transcatheter Coil and Grifka closure of the patent ductus arteriosus in comparison to our experience with the Rashkind umbrella device. Ninety seven patients (36 male and 61 females) underwent occlusion of the PDA. The following variables were compared: age, sex, ductus diameter, morphology, device, occlusion time, residual shunt, multiple device and complications. Data obtained were compared using the Student's test and Chi 2. Median patient age was 7.82 +/- 6.89, forty five patients underwent transcatheter Rashkind-17 closure, 19 patients with Rashkind-12, 18 patients with Coil and 13 patients with Grifka device, in two patients the closure could not be performed. There were differences between the morphology and device used (p = 0.008), between the ductus diameter and device used (p < 0.001). There was immediate closure in 26.7% in the Rashkind-17 group compared with, 57.9% for the Rashkind-12 group, 83.3% for Coil group and of 91.7% for Grifka group. The occlusion within 24 hrs of implantation was 60% with Rashkind-17, 78.9% with Rashkind-12, 94.4% with Coil and 100% with Grifka. Residual shunt persisted for more than a year in 7 patients with Rashkind-17 and 1 with Rashkind 12, (p = 0.001), in 4 patients two devices wore placed. The complications were, 15.5% for Rashkind-17, 26.3% for Rashkind-12, 5.2% for Coil and 30% for Grifka, (p = 0.004), one coil and one Grifka embolized. Transcatheter Coil and Grifka occlusion are more effective in achieving immediate closure than the Rashkind device. The indication to use each device is made according to the morphology and size of the ductus.  相似文献   

3.
In 14 patients undergoing transcatheter closure of a large (greater than 4 mm diameter) patent ductus arteriosus, occlusion was attempted with use of the Bard Clamshell septal umbrella. Patient age ranged from 0.7 to 30.4 years. Isolated patent ductus arteriosus was present in 11 patients; 3 had additional congenital heart lesions. Moderate or severe pulmonary hypertension was present in four patients. The diameter of the patent ductus arteriosus ranged from 4.5 to 14 mm, as determined by contrast injection through an 11F sheath or by balloon sizing; it appeared larger by this method than by the standard angiographic method. All 14 patent ductus arteriosi were successfully closed. Prior embolization of a Rashkind umbrella was the reason for using a Clamshell device in three patients; one additional embolization of a Clamshell device occurred. All errant devices were retrieved at cardiac catheterization, without associated hemodynamic instability. No other complications occurred. Among the 14 patients, 11 had complete ductal closure by Doppler color flow mapping at last follow-up and 3 had trivial residual flow. All four patients having associated complex lesions or pulmonary hypertension, or both, had symptomatic improvement after the procedure, although one child (with Shone's anomaly) died 3 months later. The Clamshell device provides stable and effective closure of a large patent ductus arteriosus, and allows transcatheter closure to be offered to some patients who were previously considered unsuitable for this procedure.  相似文献   

4.
5.
Transcatheter coil occlusion of the patent ductus arteriosus (PDA) has become the interventional treatment option of choice. Immediate occlusion of any residual shunting results in excellent closure rates, but frequently requires multiple coil deployment. Aims: To assess the efficacy and limitations of single Cook detachable coil PDA closure compared to a preceding series of Rashkind umbrella procedures. Methods and results: Between 1990 and 1999, transcatheter occlusion of a small (<2 mm; n=45) or moderate-sized (2-4 mm; n=47) PDA was successfully attempted in 90/92 consecutive patients (mean age 6+/-4.8 years) with a coil (39/41) or Rashkind device (51/51). Immediate angiographic closure rates for both devices were low, although better for small (54-68%) than moderate ducts (7-22%, P<0.01). A 2-year echocardiographic closure rate of small ducts increased to 92% for the coil group versus 95% for the Rashkind group. By that time, moderate-sized ducts were only occluded in 64% with the coil and 54% with the Rashkind device. A visible residual shunt at post-implant angiography in moderate ducts was associated with a high incidence (59%) of long-term echocardiographic shunt patency and a need for repeat interventions for audible residual shunts (32%). Conclusions: Single coil transcatheter occlusion is the treatment of choice for the small duct as most residual shunts will resolve spontaneously. However, long-term shunt persistence after single coil deployment in moderate sized ducts is as frequent as with the Rashkind device. A primary multiple coil approach is advocated if the postcoil aortogram shows residual ductal shunting and if there is persistence of a ductal murmur on auscultation.  相似文献   

6.
Successful transcatheter closure of a calcified patent ductus arteriosus was performed in a symptomatic 78 year old man. Cardiac catheterization revealed a left to right shunt across the patent ductus arteriosus with a pulmonary to systemic flow ratio of 2.8:1. Calcification of the ductus and severe lung disease increased the risk of surgical patent ductus arteriosus closure. A 17 mm Rashkind double umbrella was positioned in the ductus percutaneously by way of the femoral vein. After closure of the ductus there was marked hemodynamic improvement and the patient was discharged with improved exercise tolerance. Transcatheter closure of patent ductus arteriosus may be a viable option for the elderly patient too sick to withstand cardiovascular surgery.  相似文献   

7.
We present the short- and intermediate-term results of transcatheter closure of patent ductus arteriosus with Gianturco coils in adolescents and adults. During a 5-year period, 55 patients (44 females, 11 males) with ages ranging from 14 to 72 years (median, 23) underwent attempted transcatheter closure of patent ductus with the Gianturco coils. The diameter of the narrowest segment of the ductus ranged from 0.8 to 7.6 mm (3.9 +/- 1.3 mm). The 55 patients were divided into three groups. Group I consisted of nine patients with a ductal diameter < or = 3 mm, group II consisted of 27 patients with a ductal diameter > 3 mm but < or = 4 mm, and group III consisted of 19 patients with a ductal diameter > 4 mm. Four- to five-loop Gianturco coils were used, which were deployed via retrograde aortic route. Multiple-coil technique was generally applied in group II patients. Balloon occlusion technique in combination with multiple-coil technique was generally used in group III patients. Deployment of coil was successful in 51 patients (93%) but failed in 4. The success rate of coil deployment in group I, II, and III were 100% (9/9), 96% (26/27), and 84% (16/19), respectively. A mean of 1.9 +/- 0.7 coils was deployed per patient. Of the four patients with unsuccessful coil deployment, three underwent surgery and one received implantation with Amplatzer duct occluder. Distal embolization of 21 coils occurred in 10 patients (3 in group II and 7 in group III), from whom 20 coils were retrieved with a gooseneck snare and 1 coil was removed during surgery. The mean diameter of ductus in the 10 patients with distal embolization was significantly larger than that in those without (5.2 +/- 1.4 vs. 3.7 +/- 1.1 mm; P < 0.01). Among the 51 patients with successful coil deployment, immediate complete closure was achieved in 20 (39%), while trivial to mild leak was present in 31 (61%). No significant complications were encountered. After a follow-up period ranging from 5 to 42 months, four patients had a small residual shunt and three underwent a second intervention with complete occlusion. None had left pulmonary artery stenosis documented with Doppler echocardiography. Transcatheter closure of ductus with the Gianturco coils is safe and feasible in the majority of adolescents and adults. Taking high embolization rate in patients with a ductus diameter > 4 mm into consideration, controlled-release coils, Buttoned device, or Amplatzer duct occluder can be a better choice.  相似文献   

8.
Transcatheter closure of patent ductus arteriosus is routinely performed using various devices. After the withdrawal of the Rashkind umbrella device from the market, the wide window-type patent ductus arteriosus has been difficult to close percutaneously. Two patients with this condition are presented: a 17-year-old man and a 62-year-old woman with short (4.5- and 5.2-mm-diameter, respectively) ductus. We successfully implanted a 17-mm CardioSEAL device in the 1st patient and a 23-mm STARFlex in the 2nd, with no residual shunt at follow-up (22 and 8 months, respectively). Although these devices (which follow the general design of the Rashkind umbrella) are usually applied to atrial septal defect closure, we believe that CardioSEAL and STARFlex implants could be the treatment of choice in percutaneous treatment.of window-type patent ductus arteriosus.  相似文献   

9.
目的探讨经导管封堵动脉导管未闭(PDA)介入治疗后残余分流的可行性和临床疗效。方法自1997年3月至2001年8月16例PDA介入治疗后残余分流的患者,其中男4例,女12例,平均年龄5.9±2.4岁(2~9岁),平均体重17.7±5.4kg(9~28kg),应用不同介入方法经动脉或静脉途径封堵残余分流,首次介入治疗与再次介入治疗的时间间隔平均为1.5±1.1年(1天~3.5年)。结果残余分流直径平均为2.7±0.9mm(1.2~5.0mm)。15例成功完成残余分流封堵术,1例失败,技术成功率为94%(15/16)。单纯应用Cook可控弹簧圈9例(其中双弹簧圈2例),Rashkind双面伞2例,Sidris纽扣式补片1例,Amplatzer蘑菇伞2例,同时应用Cook可控弹簧圈和Sidris纽扣式补片1例。封堵术后即刻造影,3例仍有少量残余分流,完全闭合率为80%(12/15)。平均手术时间为75.0±22.8min(45~120min),平均X线透视时间为10.4±3.9min(5~20min)。股动脉并发症1例,其余无并发症出现。封堵术后24h复查超声心动图,所有残余分流均完全闭合(100%),在平均2年随访中未出现残余分流再通、封堵器移位和左右肺动脉狭窄。结论经导管封堵PDA介入治疗后残余分流安全、疗效确切、创伤小,可作为外科手术治疗PDA介入治疗后残余分流的一种替代方法。  相似文献   

10.
Two patients who underwent transcatheter closure of patent ductus arteriosus, one with a Rashkind umbrella device and the other with a coil, suffered from acute hemolysis following the procedure. Hemolysis ceased after deployment of second device(s) within 48 hr without needing to retrieve the first devices in either patient. We conclude that immediate deployment of a second device(s) is an alternative to surgery when acute hemolysis occurs following transcatheter closure of ductus. Cathet. Cardiovasc. Diagn. 43:295–297, 1998. © 1998 Wiley-Liss, Inc.  相似文献   

11.
Objectives. This report summarizes our experience with the use of occluding spring coils to close the small patent ductus arteriosus.Background. Several patent ductus arteriosus occluders (most notably the Rashkind device) have been developed and studied. Occluding spring coils have been used to close abnormal vessels and vascular connections. We previously reported the use of occluding spring coils to close the small patent ductus arteriosus in a small group of patients. This report describes our series of patients having patent ductus arteriosus closure with occluding spring coils.Methods. Between June 1990 and June 1993, 30 patients underwent cardiac catheterization to have patent ductus arteriosus closure by occluding spring coils. Selection criteria were age >6 months and narrowest patent ductus arteriosus internal dimension ⪯3.0 mm by color flow imaging. Definitive selection was based on review of aortograms performed at catheterization. A 5.2F coronary catheter was used to deliver one or two standard occluding spring coils. A loop was delivered in the main pulmonary artery, and the remainder of the coil was delivered across the patent ductus arteriosus and into the aortic diverticulum. Patent ductus arteriosus closure was confirmed by aortography or color flow imaging, or both. Follow-up after coil placement occurred at 6 weeks and 6 months and included two-view chest radiography, echocardiography and color flow imaging.Results. Of the 30 patients, 29 had successful implantation by one (27 patients) or two (2 patients) occluding spring coils. Of these 29 patients, 19 had a clinically apparent and 10 had a silent patent ductus arteriosus. Average ductus minimal internal dimension was 1.7 mm (range 1.0 to 3.0). Complete closure of the ductus was confirmed in 27 patients by aortography or color flow imaging or both (in 24 within 4 h, in 2 after 6 weeks and in 1 after 6 months). Six weeks after implantation, two patients had a tiny residual patent ductus arteriosus noted on color flow imaging. One patient did not have successful implantation. This patient had a 3.2-mm ductus, and two coils migrated to the distal left pulmonary artery and could not be retrieved. There were no deaths or any significant complications noted during early or late follow-up in these patients.Conclusions. Occluding spring coils may have additional application in closing the small patent ductus arteriosus.  相似文献   

12.
Transcatheter closure of patent ductus arteriosus (PDA) is now a well-established treatment alternative to surgery in many cardiology centers. Of all the methods used, transcatheter coil occlusion is the preferred therapy. For small PDA, the method using 0.038" Gianturco coils has proven safe and effective. However, this therapeutic strategy has encountered some difficulties with large PDA. This study provides an alternative strategy, using 0.052" Gianturco coil and complete closure of residual shunt with multiple coils to close large PDA. Fifteen patients underwent transcatheter coil occlusion of large ( > or = 4mm) patent ductus arteriosus. The intermediate success rate was 86.7%. There were four complications and only two patients had to be referred for surgery.  相似文献   

13.
AIM: To report results of transcatheter occlusion of moderate to large patent arterial ducts, having a minimum diameter above 2.5 mm, with the Amplatzer duct occluder, and to compare these with results achieved using Rashkind or Sideris devices and Cook detachable coils. DESIGN AND SETTING: Retrospective study conducted on intention-to-treat data from a tertiary referral centre. PATIENTS: Since 1989, 116 consecutive patients, 77 females and 39 males, underwent percutaneous closure with several devices. We used the Rashkind double umbrella in 23 patients, the Sideris buttoned device in 39 patients, coils in 17 patients, and the Amplatzer duct occluder in 37 patients. The median age of the patients was 37 months, and the median weight 13 kg. The mean minimum diameter of the duct was 3.8 +/- 1.22 mm, with a median of 3.5 mm, and range from 2.5 to 10 mm. RESULTS: Implantation succeeded in all but 9 of the children (92%). The time of fluoroscopy was shorter, and full occlusion was better as judged on angiography, in patients closed using the Amplatzer device, despite closure of larger ducts, than in patients closed using other devices (p < 0.0001, p = 0.0003, and p = 0.0015 for the Rashkind, Sideris, and coils, respectively). Complications included embolisation in 2 patients, and haemolysis in 3 patients. In 12 patients, a second device was inserted because of residual shunting noted during follow-up. Complete occlusion was achieved earlier after implantation (p = 0.0002), and the rate of complete occlusion was better in patients receiving an Amplatzer device (97%, p = 0.024) than in patients undergoing closure with other devices. CONCLUSION: Transcatheter closure of moderate to large patent arterial ducts using the Amplatzer duct occluder is an effective and safe procedure, providing better results than those achieved using other occluders.  相似文献   

14.
BACKGROUND AND METHODS: Percutaneous closure of a moderate-to-large sized patent ductus arteriosus using multiple coils or a Rashkind double-umbrella may be technically demanding and raises a significant rate of embolization and residual shunting. This is why we tried a new self-expandable device called Amplatzer Duct Occluder to close transvenously large ductuses in eighteen patients at a median age of 2.8 years (range: 0.7 to 34). They had a patent ductus arteriosus with a minimal diameter > 3 mm (mean: 5 +/- 2 mm). The device had a mean diameter of 9 +/- 2 mm and was delivered through a 6F venous sheath. Aortography was done 5 to 10 minutes after the release and follow-up evaluation was performed with color Doppler echocardiography within 24 h, 1 and 3 to 6 months after the procedure. RESULTS: Placement was successful in all but the first patient (95%). Complete closure was achieved immediately in 4/17 patients (24%) and in 13/17 (76%) 24 h later. Two patients were lost for follow-up. Complete closure was confirmed in 14 of the 15 (93%) reviewed patients at 1 and 3 months. In all patients with a ductal diameter < or = 7.5 mm the closure was complete at 1 month. Embolization occurred in one patient with a 9.7 mm duct and surgery was undertaken. A mild and transient hematuria was observed in one patient. No pulmonary artery stenosis nor aortic obstruction were observed on follow-up. CONCLUSION: The Amplatzer Duct Occluder device offers a safe and effective option to treat patients with a ductus arteriosus which minimal diameter is up to 7.5 mm.  相似文献   

15.
Objectives: The present study evaluates two transcatheter closure strategies utilized at a single center and makes recommendations for device selection when occluding the patent ductus arteriosus. Background: A variety of devices are available for transcatheter closure of the patent ductus arteriosus (PDA) but no guidelines exist to guide operator device choice. Methods: A total of 132 patients underwent attempted transcatheter PDA closure utilizing one of two consecutive closure strategies between January 2000 and June 2005. Strategy A (n = 64; January 2000–May 2003) utilized Gianturco coils only. Strategy B (n = 68; June 2003–June 2005) utilized a single Gianturco coil for the PDA with a minimal diameter ≤1 mm (n = 28) or an Amplatzer Duct Occluder (ADO) if the PDA diameter exceeded 1 mm (n = 40). Success was defined as complete occlusion on a follow up echocardiogram. Results: 58 of 64 (90.6%) patients treated utilizing strategy A had successful coil implantation. 68 of 68 (100%) patients treated utilizing strategy B had successful coil/device implantation. At follow up echocardiography, 32 of 44 (72.7%) strategy A patients had complete ductal closure, as compared with 57 of 58 (98.3%) strategy B patients (P < 0.0001). Stepwise logistic regression analysis identified closure strategy as the most powerful predictor of procedural success (OR = 85.9; CI 5.6–9.99). Conclusions: A transcatheter PDA closure strategy consisting of a single Gianturco coil for PDA ≤ 1 mm or an ADO for larger sized PDA (strategy B) achieves superior outcomes compared to the use of coils alone. © 2008 Wiley‐Liss, Inc.  相似文献   

16.
BACKGROUND: Surgical closure of patent ductus arteriosus in adult patients may be problematic. Transcatheter closure of patent ductus arteriosus is an established procedure. Recently, transcatheter closure of patent ductus arteriosus using the Amplatzer duct occluder has been shown to be safe and efficacious. We present our experience with this device in adults. METHODS AND RESULTS: Between January 2000 and January 2002,41 adult patients (31 females and 10 males) with a patent ductus arteriosus were referred for closure with the Amplatzer duct occluder. The median age was 35.6 years (range 18-70.7 years) and the median weight was 65.8 kg (range 32.7-164.5 kg). Of these 41 patients, 37 underwent attempted closure of the patent ductus arteriosus using the Amplatzer duct occluder. The device was successfully deployed in all patients except 1. Complete angiographic closure was seen Immediately after device deployment in 29 out of 36 patients (81%). Complete echocardiographic closure was demonstrated within 24 hours post-procedure in 34 out of 36 patients (94%), and at 6-month follow-up in 35 out of 36 patients (97%). No complications related to device implantation occurred in any patient. CONCLUSIONS: Closure of patent ductus arteriosus using the Amplatzer duct occluder is safe and effective in adults.  相似文献   

17.
OBJECTIVE: To determine the efficacy of transcatheter closure of patentarterial ducts using controlled-release coils. DESIGN: Transcatheter closure of patent arterial ducts was attemptedin 52 patients using controlled-release coils. SETTING: For the study, four tertiary paediatric cardiology units wereused, two of which were in the U.K., one in Italy and one inTurkey. PATIENTS: The 52 patients ranged in age between 3·5 months and61 years (median 3·5 years), and weighed between 4·5kg and 62 kg. The duct diameters were 1 mm to 6·5 mm. RESULTS: In four patients the ducts were too large for safe release ofthe coils. In the remaining 48, one coil was inserted in 33patients, two coils in nine, three coils in four and four coilsin two patients. Immediately at the end of the procedure, theduct was completely occluded in 26/47 (55%) patients. Haemolysisoccurred in one patient, in whom the coil was removed by a snarecatheter and a large umbrella device was implanted with resolutionof the haemolysis. Coil embolization to the pulmonary arteryoccurred in five (10%) patients. All were easily retrieved andreplaced by larger coils. At the latest follow-up by colourDoppler echocardiography, the duct was completely occluded in44/47 (94%) patients. CONCLUSIONS: Transcatheter closure of patent arterial ducts by controlled-releasecoils is effective and safe. Even when more than one coil isinserted the technique is still less cumbersome and considerablycheaper than transcatheter umbrella closure.  相似文献   

18.
OBJECTIVE: To assess the immediate and mid-term results of transcatheter closure of patent ductus arteriosus (PDA) > or = 4 mm with multiple Gianturco coils. (Transcatheter closure of large PDAs using the Rashkind occluder or the buttoned device is associated with a 7-38% incidence of residual shunt.) METHODS: 19 patients (7 male, 12 female) underwent an attempt at anterograde transcatheter closure with multiple Gianturco coils of a large PDA at a median age of 3.8 yr (range 2 weeks-34 yr) and median weight of 14 kg (range 2.3-80 kg). RESULTS: The median PDA diameter at the narrowest segment was 4.3 mm (range 4-7 mm) and the mean (SD) Qp/Qs was 1.9 (0.8). Each patient had left atrial and left ventricular volume overload. A 4F catheter was used to deliver the coils in all patients. There was immediate and complete closure in 16/18; one patient had residual shunt that was closed at a second procedure and the other had spontaneous disappearance of the residual shunt at the six week visit. A short ductus (angiographic type B) in one patient could not be closed. The median number of coils placed at the first attempt to close the ductus was 4 (range 2-6 coils) and the median fluoroscopy time was 40 minutes (range 13-152 minutes). Mild left pulmonary artery stenosis occurred in the two smallest patients. Coil migration to the lung occurred in 3 patients with retrieval of coils in two patients. All procedures but one were done on an outpatient basis. At a median follow up of 1.6 yr (range 2 weeks-2.2 yr) all patients had complete closure with no new complications. CONCLUSIONS: Anterograde transcatheter closure with multiple Gianturco coils is an effective treatment for most patients with large PDA of diameters up to 7 mm. This technique can be performed in small infants on an outpatient basis without the need for general endotracheal anaesthesia.  相似文献   

19.
Transcatheter closure of congenital muscular ventricular septal defect   总被引:18,自引:0,他引:18  
The success with occlusion devices for the closure of atrial septal defects and patent ductus arteriosus prompted the transcatheter closure of single and multiple muscular ventricular septal defects (VSD). The procedure for VSD was first attempted by Lock et al. in 1988 and devices originally designed for the closure of other intracardiac defects (Rashkind umbrella device, Lock clamshell, Cardioseal, coils, Sideris buttoned device etc.) were used with a variable success rate and a residual shunt. Recently, specially designed Amplatzer muscular VSD occluder and Sideris device are in use. The Amplatzer muscular VSD occluder has been undergoing clinical trial since 1998 after the animal experiments had shown 100% occlusion and complete endothelization at 3 months. The procedure was first attempted in August 1995 using the Rashkind umbrella device and since April 1998 only the Amplatzer muscular VSD occluder has been used. Of the149 patients who underwent transcatheter closure of VSD, 50 had muscular trabecular defects in various locations: mid-muscular, anterior, posterior, or apical. All cases were selected by detailed transthoracic and/or transesophageal echocardiography (TTE) and aneurysm of the muscular septum was observed in three of them. The age range was 3-28 years and the diameter of VSD was 4-11 mm. In all but one patient, the device was deployed from the venous side. Simultaneous TTE was done for proper positioning of the device and continuous electrocardiographic monitoring was also done for any arrhythmia/conduction defects. All patients were followed up every 3 months and received 3-5 mg/kg aspirin for 6 months. The procedure was successful in all patients. The Rashkind umbrella device (17 mm) was used in two and Amplatzer muscular VSD occluder (6-14 mm) in 48 patients. Forty-four devices were delivered by antegrade transvenous approach and six by the transjugular route. None had residual shunt, new aortic regurgitation, or tricuspid regurgitation. Transient complete heart block after 24 hours was noticed in one patient. On a follow-up of 2-90 months, the device was in position in all patients. There was no embolization of the device, and no late-conduction defects, infective endocarditis, or hemolysis. Transcatheter closure of muscular VSD is safe and efficacious, and should be considered as a procedure of choice as an alternative to surgery that avoids cardiopulmonary bypass.  相似文献   

20.
Background: The Rashkind Umbrella device has proven effective in closing small to moderate size patent ductus arteriosus. A comparable early occlusion rate was also seen in PDA occlusion using Gianturco coils. This study addresses the long-term outcome of both techniques in a single centre. Methods: Review was undertaken of 522 patients with PDA who underwent transcatheter occlusion before January 1997; 244 patients (mean: age 8.0±6.7 years, weight 21.8±12.9 kg, PDA size 3.2±1.0 mm) were intended to receive the Rashkind Umbrella device and the remaining 278 patients (mean: age 6.4±5.6 years, weight 18.6±11.2 kg, PDA size 2.5±1.0 mm) would receive Gianturco coils. Deployment failure occurred in 8 patients (3%) and 6 (2%) during the initial learning curve of the Rashkind Umbrella and Gianturco coil, respectively. In the Rashkind Umbrella group, haemolysis occurred in 6, device embolisation in 3, and 1 patient died from anaesthetic sequelae. Peripheral pulmonary embolisation of coils occurred in 7 patients and all were successfully retrieved. Results: Results were analysed from 228 and 258 patients who had successful Rashkind Umbrella device and Gianturco coil deployment respectively. All had completed at least 1 year follow-up. They were evaluated clinically for residual ductal murmur and echocardiographically for a residual ductal shunt and presence of pulmonary artery or aortic obstruction. The Rashkind Umbrella group had significantly higher residual shunt compared to the Gianturco coil group at various stages of follow-up (p<0.05), 40% v 22% at 24 hours, 29% v 7% at 3 months, 25% v 4% at 6 months and 22% v 3% at 1 year. In 57 patients, a reocclusion procedure during the study period was undertaken to effect immediate complete occlusion. Mild left pulmonary artery stenosis (velocity<2 m/s) was noted in 6 patients who had multiple coils and one who had a 17 mm Rashkind Umbrella device. Conclusions: Transcatheter occlusion of PDA using the Gianturco coil is safer and more effective than the Rashkind Umbrella device. It has become the first choice for treating small to moderate size native PDA at our institution.  相似文献   