首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.

Background

Bearing surface issues related to trunnionosis or metal-on-metal (MoM) articulations have likely impacted recent trends in bearing surface choice. The purpose of this study is to evaluate trends in total hip arthroplasty (THA) bearing surface use, including 2015 data, with respect to the date of operation and patient demographics.

Methods

The Humana dataset was reviewed from 2007 through 2015 to analyze bearing surface usage in primary THA. Four bearing surface types were identified by International Classification of Disease, 10th Revision codes and trended throughout the years: metal-on-polyethylene (MoP), ceramic-on-ceramic (CoC), ceramic-on-polyethylene (CoP), and MoM. Prevalence was analyzed as a function of age and sex.

Results

Of the 28,504 primary THA procedures, the most commonly used bearing was MoP (46.1%), followed by CoP (33.2%), MoM (17.1%), and ceramic-on-ceramic (3.6%). The use of CoP bearings significantly increased from 6.4% in 2007 to 52.0% in 2015, while MoM bearings decreased during this period. MoP bearings decreased over 2012-2015 (P < .001). CoP usage decreased with age, while MoP bearings increased with a transition occurring at 65-69 years of age. Women were more likely to receive MoP bearings (odds ratio [OR] 1.2), while men were more likely to receive MoM and CoP bearings (OR 1.1). Multivariate logistic regression showed age to be an independent predictor of bearing surface choice with patients 65 and older more likely to receive MoP bearings (OR 3.2).

Conclusion

Bearing surface choice in primary THA has changed tremendously from 2007 to 2015. MoM bearing use has decreased as a result of adverse effects. Age continues to remain a significant factor in bearing surface choice.  相似文献   

2.
3.

Introduction

Hard-on-hard (HoH) bearing surfaces in total hip arthroplasty (THA) are commonly utilized in younger patients and may decrease mechanical wear compared to polyethylene bearing surfaces. To our knowledge, no study has prospectively compared the 2 most common HoH bearings, ceramic-on-ceramic (CoC) and metal-on-metal (MoM) THA.

Materials and Methods

We prospectively enrolled 40 patients to undergo an MoM THA and 42 patients to undergo a CoC THA utilizing the same acetabular component. Patients were followed up for a minimum of 2 years. Comparative outcomes included clinical scores, revision or reoperation for any reason, complication rates, and radiographic outcomes.

Results

The average follow-up was significantly longer in the CoC cohort (94 vs 74 months; P = .005). The CoC cohort had significantly improved Harris Hip Scores (95 vs 84; P = .0009) and pain scores (42 vs 34; P = .0003). The revision (0% vs 31%; P = .0001), reoperation (7.5% vs 36%; P = .004), and complication rates (10% vs 56%; P = .0001) were significantly lower in the CoC cohort. There were no statistically significant differences in radiographic parameters.

Conclusion

The clinical outcomes in the CoC cohort exceeded the MoM cohort. It is unlikely that another prospective comparative study of HoH THAs will be conducted. Our midterm results support the use of CoC THA as a viable option that may reduce long-term wear in younger patients. Close surveillance of MoM THA patients is recommended considering the higher failure and complication rates reported in this cohort.  相似文献   

4.

Background

We analyzed the data for primary total hip arthroplasty (THA) in the Korean nationwide database to assess (1) the epidemiology and national trends of bearing surface usage in THAs and (2) the prevalence of each type of bearing surface according to age, gender, hospital type, primary payer, and hospital procedure volume.

Methods

A total of 30,881 THAs were analyzed using the Korean Health Insurance Review and Assessment Service database for 2007 through 2011. Bearing surfaces were sub-grouped according to device code for national health insurance claims and consisted of ceramic-on-ceramic (CoC), metal-on-polyethylene (MoP), ceramic-on-polyethylene (CoP), and metal-on-metal (MoM). The prevalence of each type of bearing surface was calculated and stratified by age, gender, hospital type, primary payer, and procedure volume of each hospital.

Results

CoC was the most frequently used bearing surface (76.7%), followed by MoP (11.9%), CoP (7.3%), and MoM (4.1%). The proportion of THAs using a CoC bearing surface increased steadily from 71.6% in 2007 to 81.4% in 2011, whereas the proportions using CoP, MoP, and MoM bearing surfaces decreased. The order of prevalence was identical to that in the general population regardless of age, gender, hospital type, primary payer, and hospital procedure volume.

Conclusions

The trends and epidemiology of bearing surface usage in THAs in Korea are different from those in other countries, and the CoC bearing surface is the most prevalent articulation. In future, the results of a large-scale study using nationwide data of THAs involving a CoC bearing surface will be reported in Korea.  相似文献   

5.
《The Journal of arthroplasty》2021,36(10):3519-3526
BackgroundTotal hip arthroplasty (THA) performed for developmental dysplasia of the hip is a technically difficult procedure with a high complication rate, especially in the presence of completely dislocated hips. This study aimed to evaluate at least 10 years of follow-up results of cementless, ceramic-on-ceramic (CoC) THA performed with transverse subtrochanteric osteotomy in Crowe type IV hips.MethodsWe retrospectively reviewed 50 patients’ 67 hips that underwent CoC, cementless THA with transverse subtrochanteric osteotomy between 2008 and 2011. Clinical and radiological data of the hips were examined. Clinical results were evaluated using the Harris Hip Score and the Western Ontario and McMaster Universities Osteoarthritis Index.ResultsThe mean Harris Hip Score improved from 22.9 ± 9.9 preoperatively to 94.1 ± 8.1 at the final follow-up (P < 0.001). The median Western Ontario and McMaster Universities Osteoarthritis Index score improved from 72 (interquartile range: 17) preoperatively to 2 (interquartile range: 17) postoperatively (P < 0.001). The preoperative mean leg length discrepancy was improved from 4.9 ± 1 cm to 1.5 ± 1 cm in unilateral cases at the last follow-up (P < 0.001). Revision surgery was required because of nonunion in two patients, prosthetic infection in one patient, and aseptic femoral loosening in the other patient. The overall ten-year survival rate was 94% for femoral stems and 98.5% for acetabular components as per Kaplan-Meier survival analysis.ConclusionTransverse subtrochanteric shortening osteotomy combined with using cementless acetabular and femoral components with a CoC bearing surface promises successful clinical results and high prosthesis survival in the treatment of Crowe IV hips at long-term follow-up.  相似文献   

6.
We present a retrospective evaluation of 1369 hip arthroplasties performed using the Bicon-Plus cups and SL-Plus stems, differing only in the bearing combination. Four bearing combination groups were used: metal-on-polyethylene (MoP) group with 587 hips, ceramic-on-polyethylene (CoP) group with 161 hips, metal-on-metal (MoM) group with 322 hips and ceramic-on-ceramic (CoC) group with 299 hips. The mean follow-up was 11.5 years (4.1 to 15.0). Radiological evaluation was performed on implants failed due to aseptic loosening. The survival for prosthesis with revision for any reason at ten years was 96.1% (95% confidence interval (CI) 94.3 to 97.9) for MoP, 98.1% (CI 95.9 to 100) for CoP, 90.2% (CI 86.8 to 93.6) for MoM, and 95.6% (CI 93.0 to 98.2) for CoC. Survival for aseptic loosening was also determined.  相似文献   

7.
Squeaking in ceramic‐on‐ceramic (CoC) total hip arthroplasty (THA) was investigated with an acoustic monitoring device to distinguish between squeaking emanating from the trunnion morse taper (TMT) connection versus the articular surface. 82 patients with implant problems scheduled for revision were selected and acoustic emissions (AE) with simple movements monitored. Five of these patients with CoC implants underwent surgery and their retrieved implant components were analyzed in vitro. In vivo recordings of all 82 patients found audible squeaks produce frequency content across the entire 0–50 kHz spectrum. Of the five CoC implants the in vivo peak frequency range of flexion/extension motions was 0.8 kHz and comparable to the range of in vitro testing (0.2 kHz). In vitro TMT connection motions were very large comparatively, producing a higher average peak frequency range of 22.5 kHz. All retrieved implants showed evidence of wear at the TMT connection. These findings suggest, the TMT connection does not directly cause audible squeaking. Wear occurring at this junction may contribute to debris which disrupt lubrication, increase friction, and produce noise. This observation supports current evidence suggesting that squeaking is from the bearing surface. Our findings are the first to demonstrate that in CoC THA the recordable noise of a hip squeak does not originate nor have contribution from the TMT connection. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1793–1798, 2017.
  相似文献   

8.
《The Journal of arthroplasty》2022,37(10):2053-2062
BackgroundDifferent bearings have been used in total hip arthroplasty (THA), but the long-term performance is still controversial. The purpose of this study was to investigate whether there are differences when comparing THAs with 5 different bearings at a long-term follow-up of more than 10 years.MethodsFrom January 2010 to May 2012, 101 THA patients (134 hips) were divided into metal-on-metal group (MoM, 31 hips), metal-on-polyethylene group (MoP, 23 hips), ceramic-on-metal group (CoM, 21 hips), ceramic-on-ceramic group (CoC, 33 hips), and ceramic-on-polyethylene group (CoP, 26 hips). The mean follow-up period was 10.3 years. The Harris hip score (HSS), Western Ontario and McMaster Universities Osteoarthritis Index scores (WOMAC), range of motion (ROM), blood cell count, and liver-kidney function were measured. Serum and urine metal ion levels were measured using high-resolution inductively coupled plasma-mass spectrometry (ICP-MS) and a blood lymphocytes analysis was counted by flow cytometry.ResultsNo difference was observed in the HSS, WOMAC, ROM, blood cell count, or liver-kidney function among any of the 5 groups. Metal ion levels were significantly elevated in metal-containing bearings. Flow cytometry showed that no differences were found. Revision was performed due to pseudotumor in 3 patients. The implant survival rate was 96.7% and 93.3% for the MoM and CoC groups, which was significantly lower compared with other groups.ConclusionsMetal ion levels were elevated significantly in metal-containing bearings, especially in MoM THA patients. The implant survival rate was significantly lower in CoC and MoM THAs, which was mainly due to pseudotumor formation.Level of EvidenceTherapeutic Level II.  相似文献   

9.
Purpose: The widespread usage of metal‐on‐metal (MoM) articulations in total hip arthroplasty (THA) has been tempered by concerns of increased metal ion production. The purpose of the study is to evaluate the influence of metal ion exposure on semen quality in young male patients undergoing THA. Methods: Male patients who were scheduled for unilateral THA and aged between 20 and 45 years were prospectively enrolled. Patients were sorted into MoM and metal‐on‐polyethylene (MoP) groups with equal case number. Semen and blood metal ion levels were measured and sperm analysis was performed before, 6 months after, and 1 year after surgery. Results: Compared to preoperative baseline, patients (n = 50) in both groups had increased cobalt (Co) and chromium (Cr) concentrations in blood and seminal fluid after surgery. Between‐group comparisons at 6 months and 1 year after surgery showed that patients in the MoM group both had a greater Co concentration in blood and semen and a greater Cr concentration in blood and semen. Patients receiving MoM prosthesis had a reduced percentage of morphologically normal sperm, and decreases from the preoperative level (44.7%) were significant at 6 months (36.8%, p = 0.03) and 1 year (33.8%, p = 0.004). Conclusions: Our data shows a significantly greater concentration of metal ion in blood and semen in patients with MoM prosthesis with a reduced percentage of morphologically normal sperm. Despite small effects on sperm quality, some concerns remain. Further studies are necessary to determine sources of metal ion and to investigate effects on male fertility. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:544–551, 2016.  相似文献   

10.
Background:Most literature in the field of total hip arthroplasty (THA) for fused hips, until date has reported the results of using metal on polyethylene and ceramic on polyethylene bearings. Results of THA using ceramic on ceramic (CoC) bearings in fused hips have not been published in literature. This study reports the results of cementless THA using CoC articulation perfomed in fused hips.Results:Mean Harris hip score improved from 42.4 to 84.2 and mean leg lengthening of 36.6 mm was achieved. In the average 5.4 years (range 2.8-9.1 years) followup there were no cases with osteolysis around acetabular cup and femoral stem. In this study, there was no case of ceramic fracture. There was one case of squeaking.Conclusion:This study suggests that cementless THA performed for fused hips with CoC bearings can provide good early clinical results.  相似文献   

11.
Resurfacing (RA) and total hip arthroplasty (THA) are options in the treatment of debilitating hip pathology. 381 patients that had undergone arthroplasty with a BHR RA, ASR RA, metal-on-metal (MoM) THA or ceramic-on-ceramic (CoC) THA were reviewed for satisfaction, function, health and survivorship at a median follow up of 50 months. Significantly lower survivorship for revision and reoperation was observed in the ASR group. The BHR and CoC demonstrated better outcome scores than the ASR (OHS and SAPS) and the BHR better scores than the MoM (OHS and SF12 PCS). In the short to medium term, survivorship and outcomes for the best performing RA (BHR) and THA (CoC) were comparable. There was a non-significant trend towards poorer outcome scores in the MoM THA group.  相似文献   

12.
At a minimum follow-up of ten years we compared clinical and radiographic findings and survivorship in a cohort of 412 patients (447 hips) who received alumina on alumina CoC bearings to findings from a cohort of 216 patients (228 hips) with alumina on highly cross-linked polyethylene (HXLPE) bearings. All patients were operated for osteoarthritis. With bearing-related complications as endpoint, analysis showed no significant difference in survivorship between cohorts (99.8% for the CoC vs. 99.4% for HXLPE). In addition, there were no significant differences in clinical and radiographic findings between cohorts. We concluded that alumina on HXLPE bearings are a reasonable lower cost alternative to ceramic on ceramic bearing couples.  相似文献   

13.
王钧  潘光辉  伍振威  叶峰  段祥林 《骨科》2015,6(5):261-264
目的 比较陶瓷对陶瓷(ceramic-on-ceramic, COC)与金属对聚乙烯(metal-on-polyethylene, MOP)全髋关节置换的10年随访临床结果。 方法 对114例接受初次THA的患者进行回顾性研究,其中COC组48例(54髋),MOP组66例(67髋),比较COC与MOP两种不同摩擦界面假体的术后髋关节功能、翻修率以及不良事件发生率。 结果 末次随访时患者COC组与MOP组术后髋关节Harris评分分别为89.9±7.5和92.3±8.2,无显著性差异(P>0.05);COC组1例翻修(翻修时间术后3年),MOP组4例翻修(翻修时间平均6年)。两者在翻修、脱位、假体破碎、关节异响、无菌性松动、假体周围骨溶解、深部感染、异化骨化发生率的比较,无显著性差异(P>0.05)。结论 COC与MOP假体均能提供较好的临床疗效,两者在术后髋关节功能及并发症方面疗效相当。  相似文献   

14.

Background

Pseudotumors are a common finding in metal-on-metal (MoM) total hip arthroplasty (THA) and resurfacing hip arthroplasty (RHA). However, information on pseudotumors in metal-on-polyethylene (MoP) THA is limited.

Methods

One hundred eleven patients with 148 hip articulations—30 MoM THA, 47 MoM RHA, and 71 MoP THA—participated in a cross-sectional study at mean 7.1 (range: 0.2-21.5) years postoperatively. Patients were evaluated with metal artifact reducing sequence magnetic resonance imaging, measurements of metal ions, clinical scores of Harris Hip Score, Oxford Hip Score, the Copenhagen Hip and Groin Outcome Score, and conventional radiographs.

Results

Pseudotumors were present in 13 of 30 (43%) MoM THA, 13 of 47 (28%) MoM RHA, and 29 of 71 (41%) MoP THA patients, which was a similar prevalence (P = .10). The prevalence of mixed or solid pseudotumors was significantly higher in patients with MoP THA (n = 10) compared to MoM THA (n = 3) and MoM THA (n = 0), (P = .01). Hips with a mixed or solid pseudotumor had significantly poorer scores of Harris Hip Score (P = .01) and OHS (P = .002) and higher metal ion levels of cobalt (P = .0009) compared to hips without a pseudotumor or with a cystic pseudotumor.

Conclusion

Pseudotumors have primarily been associated with MoM hip articulations, but we found a similar pseudotumor prevalence in MoP THA, which is the most common bearing worldwide. Mixed or solid pseudotumors were more often seen in MoP THA compared with MoM hip articulations, and patients with a mixed or solid pseudotumor had poorer clinical scores and higher metal ion levels than patients without a pseudotumor or with a cystic pseudotumor.  相似文献   

15.
Thus far the ability to predict who will develop early failure following the insertion of a metal‐on‐metal (MoM) bearing has been very limited. Our objective was to assess the effect of smoking on failure rates in patients with MoM bearing, compared with patients with ceramic‐on‐polyethylene (CoP) bearing. From a prospective hospital‐based registry we included all primary THAs operated upon between 1/2001 and 12/2011 with MoM or CoP bearings of the same cup design and head size (28 mm). We compared revision rates through 10/2013 classified by smoking status and type of bearing. We included 1,964 patients (median age 71, 57% women), 663 with MoM and 1,301 with CoP bearing. Mean follow‐up was 6.9 years (range 1.8–12.8). Revisions were required for 56 THAs. In patients with MoM bearing the adjusted incidence rate of revision among ever‐smokers was four times greater than among never‐smokers (95% CI 1.4–10.9). Among those with CoP bearing, the rate ratio was only 1.3 (95% CI 0.6–2.5). We found a strong association between smoking and increased failure of MoM THAs. In contrast, the association was weak for patients with CoP bearing. Smoking might be a trigger or an effect amplifier for adverse reactions to metal debris from MoM bearings. © 2014 The Authors. Journal of Orthopaedic Research Published by Wiley Periodicals, Inc. J Orthop Res 32:762–768, 2014.  相似文献   

16.
《The Journal of arthroplasty》2021,36(10):3498-3506
BackgroundProsthetic joint infection (PJI) is a devastating complication. Studies have suggested reduction in PJI with the use of ceramic bearings.MethodsAdult patients who underwent total hip arthroplasty (THA) using an uncemented acetabular component with ceramic-on-ceramic (CoC), ceramic-on-polyethylene (CoP), or metal-on-polyethylene (MoP) bearing surfaces between 2002 and 2016 were extracted from the National Joint Registry for England, Wales, Northern Ireland, and the Isle of Man. A competing risk regression model to investigate predictors of each revision outcome was used. Time-to-event was determined by duration of implantation since primary surgery with competing risks being death or revision. The results were adjusted for age, gender, American Association of Anaesthesiologists grade, body mass index, surgical indication, intraoperative complications, and implant data.ResultsIn total, 456,457 THAs (228,786 MoP, 128,403 CoC, and 99,268 CoP) were identified. Multivariable modeling showed that the risk of revision for PJI was significantly lower with CoC (risk ratio 0.748, P < .001) and CoP (risk ratio 0.775, P < .001) compared to MoP. Significant reduction in risk of aseptic and all-cause revision was also seen. The significant protective effect of ceramic bearing was predominantly seen 2 years after implantation. Aseptic revision beyond 2 years reduced by 18.1% and 24.8% for CoC and CoP (P < .001), respectively. All-cause revision rate beyond 2 years reduced by 21.6% for CoC and 27.1% for CoP (P < .001)ConclusionThis study demonstrates an association between the use of ceramic as part of the bearing, with lower rates of revision for all causes, revision for infection, and revision for aseptic causes, supporting ceramic bearings in THA.  相似文献   

17.
This study determined how ceramic-on-ceramic bearing THA affected joint-specific pain, function and stiffness in the first five postoperative years compared with ceramic-on-highly-crosslinked-polyethylene bearing THA. Subjects less than 61 years of age were randomized to ceramic-on-ceramic (CERAMIC) [n = 48] or ceramic-on-highly-crosslinked-polyethylene (POLYETHYLENE) [n = 44] bearing THA. Subjects were assessed using the Western Ontario McMaster Osteoarthritis Index (WOMAC) and the RAND 12-Item Health Survey (RAND-12) preoperatively, and at one and five years postoperatively. 92 subjects(50 (54%) males; average age = 52 (SD 6.6) years) were enrolled. 78 (85%) subjects returned five years postoperatively. All subjects reported improvements at one and five years in all measured indices with no group differences detected. Seven (8%) subjects experienced postoperative THA complications, none related to bearing surfaces; two subjects (POLYETHYLENE) required revision for instability. Both bearing surfaces provided excellent short-term results in younger subjects.  相似文献   

18.
The use of large diameter metal bearing total hip arthroplasty (THA) and hip resurfacing arthroplasty (HRA) increased in popularity in the last decade. More recent literature has highlighted the effect of head size in patient outcomes. Data was obtained from the Australian Orthopaedic Association National Joint Replacement Registry (AOA-NJRR) to evaluate the Birmingham (MoM) bearing surface when used with THA and HRA. There is no difference in the overall rate of revision between the THA and HRA but head size has a significant effect on revision rate. The data show that small diameter metal bearings in HRA (below 50 mm) have a higher rate of revision than large diameter metal bearings in HRA (equal to and above 50 mm) (P < .001). Conversely the large diameter metal bearings in THA have a higher rate of revision than the small diameter metal bearings in THA (P = .027). The revision rate for large diameter HRA compared to small diameter THA is not significantly different P = .670. We recommend caution when choosing either a large diameter (≥ 50 mm) metal on metal THA or small diameter (< 50 mm) HRA.  相似文献   

19.

Background

Dislocation is a leading cause of revision after primary total hip arthroplasty (THA). Although more common in the first few years after the procedure, dislocation can occur at any time. This study investigated the difference in late dislocation in ceramic-on-ceramic (CoC) bearings compared with metal-on-polyethylene and ceramic-on-polyethylene bearings in THA.

Methods

Data were used from the Australian Orthopaedic Association National Joint Replacement Registry, and the cumulative percent revision for dislocation was estimated using the Kaplan-Meier method for the different bearing surfaces. There were 192,275 THAs included in the study with 101,915 metal-on–cross-linked polyethylene (MoXLPE), 30,256 ceramic-on–cross-linked polyethylene (CoXLPE), and 60,104 CoC.

Results

The cumulative percent revision for dislocation at 13 years for MoXLPE, CoXLPE, and CoC groups was 1.2 (95% confidence interval [CI], 1.1-1.3), 1.0 (95% CI, 0.7-1.4), and 0.9 (95% CI, 0.8-1.1), respectively. There was an increased risk of revision for dislocation for MoXLPE compared with CoXLPE and CoC. When stratified for head size, there was no difference in the risk of revision for dislocation between MoXLPE, CoXLPE, and CoC in the 28- and 32-mm head sizes. With a head size of 36 mm, MoXLPE had a higher rate of dislocation compared with other materials.

Conclusion

Bearing surface has little impact on revision for dislocation.  相似文献   

20.

Background

Dislocation is a major complication after primary total hip arthroplasty (THA), but little is known about the potential relationships between bearing materials and risk of dislocation. Dislocation within the first year after surgery is typically related to either surgical error or patient inattention to precautions, but the reasons for dislocation after the first year are often unclear, and whether ceramic bearings are associated with an increased or decreased likelihood of late dislocation is controversial.

Questions/purposes

The purpose of this study was to use a national registry to assess whether the choice of bearings–metal-on-polyethylene (MoP), ceramic-on-polyethylene (CoP), ceramic-on-ceramic (CoC), or metal-on-metal (MoM)–is associated with differences in the risk of late dislocation.

Methods

Data from primary THAs were extracted from the New Zealand Joint Registry over a 10-year period. The mean age of patients was 69 years (SD ± 12 years), and 53% were women. The median followup in this population was 7 years (range, 1–13 years). The surgical approach used was posterior in 66% of THAs, lateral in 29%, and anterior in 5%. The primary endpoint was late revision for dislocation with “late” defined as greater than 1 year postoperatively. A total of 73,386 hips were available for analysis: 65% MoP, 17% CoP, 10% CoC, and 7% MoM. In general, patients receiving CoC and MoM bearings were younger compared with patients receiving CoP and MoP bearings.

Results

Four percent of the hips were revised (3130 THAs); 867 THAs were revised for dislocation. Four hundred seventy THAs were revised for dislocation after the first postoperative year. After adjusting for head size, age, and surgical approach, only CoP (hazard ratio [HR], 2.10; p = 0.021) demonstrated a higher proportion of revision, whereas MoP did not (HR, 1.76; 95% p = 0.075). There were no differences of revisions for dislocation in the CoC (HR, 1.60; p = 0.092) and MoM cohorts (HR, 1.54; p = 0.081).

Conclusions

Dislocation is a common reason for revision after THA. The relationships between bearing materials and risk of revision for late dislocation remain controversial. This large registry study demonstrated that bearing surface had little association with the incidence of late dislocation. Future studies with longer followups should continue to investigate this question.

Level of Evidence

Level III, therapeutic study.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏