首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
ObjectiveThe aim of this study was to evaluate the performance of dual-mobility (DM) cup systems for revision total hip arthroplasty (rTHA) in patients who had high risk for instability.MethodsWe prospectively followed up 34 hips of 30 patients (27 females, 3 males; mean age: 66.1 (range: 33 to 89) years) who underwent rTHA with DM cups for aseptic loosening in 23 hips, infection treatment as second or single stage in nine hips, and instability in two hips. Clinical functions of the patients were evaluated using the Harris Hip Score (HHS), and radiological migration or loosening of the DM cups were recorded. The survival of the components was calculated with the Kaplan-Meier survival analysis and failure was defined as any dislocation of the polyethylene (PE) insert, intraprosthetic dislocation (IPD), aseptic loosening of any component or total hip system revision due to any reason.ResultsThe mean duration of follow-up was 3.52 (range: 2.05 to 6.26) years. There was one dislocation of PE insert (2.9%), which was treated with closed reduction. There were two (5.8%) re-revisions for cemented DM cup due to migration. There was one PE insert and head change due to subacute infection. The mean HHS increased from 42.8 ± 6.7 (range: 34 to 60) points preoperatively to 87.3 ± 5.8 (range: 75 to 98) points postoperatively. The cumulative survival rate of the DM cup system was 91.2% (95% CI: 81.6–100%) with any revision, 94.1% (95% CI: 86.2–100%) with aseptic loosening and %97.1 (%95 CI: 91.4–100%) with dislocation as the end point at 3.5 years.ConclusionDual-mobility cups may provide good stability and represent a good option for revision acetabular reconstruction in patients who have high risk for instability.Level of evidenceLevel IV, therapeutic study.  相似文献   

2.
《Acta orthopaedica》2013,84(6):853-865
Background?The results of total hip arthroplasty (THA) in young patients with rheumatoid arthritis (RA) have been reported in only a few studies. On a nationwide level, the outcome of THA in these patients is unknown. We evaluated the population-based survival of THA in patients under 55 years of age with RA and factors affecting the survival.

Patients?Between 1980 and 2003, 2,557 primary THAs performed for RA in patients less than 55 years of age were reported to the Finnish Arthroplasty Register.

Results?Proximally circumferentially porous-coated uncemented stems had a 15-year survival rate of 89% (95% CI 83–94) with aseptic loosening as endpoint. The risk of stem revision due to aseptic loosening was higher with cemented stems than with proximally porouscoated uncemented stems implanted during the same period (RR 2.4; p < 0.001). In contrast, Cox regression analysis showed that the risk of cup revision was significantly higher for all uncemented cup concepts than for all-polyethylene cemented cups with any cup revision as endpoint. There were no significant differences in survival between the THR concepts.

Interpretations?Uncemented proximally circumferentially porous-coated stems and cemented all-poly-ethylene cups are currently the implants of choice for young patients with RA.  相似文献   

3.
《The Journal of arthroplasty》2022,37(5):897-904.e1
BackgroundTotal hip arthroplasty (THA) for avascular necrosis (AVN) or inflammatory arthritis (IA) comes with a relatively high risk of aseptic stem loosening, especially in young patients. There are limited long-term data on the survivorship of polished, tapered, cemented stems in this population. We therefore performed a single-center retrospective study investigating the survival of this particular stem type in young patients with AVN or IA.MethodsAll patients aged ≤35 years who had received a THA for AVN or IA operated on by the senior author between 1990 and 2010 at the University Hospitals Leuven were identified. In total, 85 THAs in 62 patients were included. Primary endpoint was revision of the femoral component for aseptic loosening. Secondary endpoints were revision of the acetabular component for aseptic loosening, revision for other reasons, and the presence of radiolucencies around the components.ResultsThe mean follow-up for the entire cohort was 18.0 ± 5.3 years (range 8.0-28.9). Taking revision for aseptic loosening as endpoint, the survival of cemented stems was 100% after 15 years and 95.1% after 20 years. Survival of uncemented cups (91.3%) was significantly better than survival of cemented cups (50.3%) after 20 years of follow-up for aseptic loosening. Taking revision for any reason as endpoint, the survival of THAs with uncemented and cemented cups was 90% and 43.1% at 20 years respectively. Radiolucencies developed in the cement mantles around 11 of the 81 nonrevised stems, mainly in zones 1 and 7.ConclusionIn this cohort of young patients with high-risk profiles for aseptic stem loosening, polished, tapered, cemented stems showed excellent long-term survival rates and they therefore remain a viable alternative to uncemented stem designs.  相似文献   

4.
BackgroundInstability and aseptic loosening are the two main complications after revision total hip arthroplasty (rTHA). Dual-mobility (DM) cups were shown to counteract implant instability during rTHA. To our knowledge, no study evaluated the 10-year outcomes of rTHA using DM cups, cemented into a metal reinforcement ring, in cases of severe acetabular bone loss. We hypothesized that using a DM cup cemented into a metal ring is a reliable technique for rTHA at 10 years, with few revisions for acetabular loosening and/or instability.MethodsThis is a retrospective study of 77 rTHA cases with severe acetabular bone loss (Paprosky ≥ 2C) treated exclusively with a DM cup (NOVAE STICK; Serf, Décines-Charpieu, France) cemented into a cage (Kerboull cross, Burch-Schneider, or ARM rings). Clinical scores and radiological assessments were performed preoperatively and at the last follow-up. The main endpoints were revision surgery for aseptic loosening or recurring dislocation.ResultsWith a mean follow-up of 10.7 years [2.1-16.2], 3 patients were reoperated because of aseptic acetabular loosening (3.9%) at 9.6 years [7-12]. Seven patients (9.45%) dislocated their hip implant, only 1 suffered from chronic instability (1.3%). Cup survivorship was 96.1% at 10 years. No sign of progressive radiolucent lines were found and bone graft integration was satisfactory for 91% of the patients.ConclusionThe use of a DM cup cemented into a metal ring during rTHA with complex acetabular bone loss was associated with low revision rates for either acetabular loosening or chronic instability at 10 years.  相似文献   

5.
BackgroundThis retrospective study was conducted to know clinical and radiographic outcomes, complication rate, and survival of THA in patients with high hip dislocation secondary to developmental dysplasia(DDH) or septic arthritis of the hip(SSH).MethodsBetween March 2005 and September 2014, there were consecutive series of 53 THAs in patients with a highly dislocated hip secondary to DDH or SSH. Of these, 48 hips (DDH 24 and SSH 24) were reviewed at a mean follow-up of 7.9 years(range, 5.0-14.3 years). The mean age at the time of THA was 39.1 years(range, 18.0-59.0 years).ResultsIntraoperative blood loss, total drainage and blood transfusion amounts, and mean time to greater trochanter union were significantly lower in the DDH group than in the SSH group (P = .001, P = .039 and P = .014, and P = .015, respectively). No significant difference in Kaplan–Meier survivorship was observed between groups (log-rank, P = .343). The survival rates with an endpoint of cup aseptic loosening in cases with a cemented cup at 7.9 and 10 years (68.1% and 60.5%, respectively) were significantly lower than those in cementless cup cases (100%) at the same checkpoints (P = .019)..ConclusionWe found similar clinical outcomes between the DDH and SSH groups. However, due to poor bone quality and a lack of containment, cementless acetabular cups could not be performed in more than 50% of patients. Our experience shows that revision cementless fixation cup was possible due to reconstitution of the acetabulum in cases with failed cemented fixation.  相似文献   

6.
Background and purpose — Elderly patients may benefit from a dislocation low-risk dual-mobility (DM) articulation in total hip arthroplasty, but the best cup fixation method is unknown. We compared cup migration for cemented and cementless DM cups using radiostereometry.Patients and methods — In a patient-blinded randomized trial, 60 patients (33 female) with osteoarthritis were allocated to cemented (n = 30) or cementless (n = 30) Avantage DM cup fixation. Criteria were age above 70 years, and T-score above –4. We investigated cup migration, periprosthetic bone mineral density (BMD), and patient-reported outcome measures (PROMs) until 24 months postoperative follow-up.Results — At 24 months mean proximal cup migration was 0.11 mm (95% CI 0.00–0.23) for cemented cups and 0.09 mm (CI –0.09 to 0.28) for cementless cups. However, cementless cups generally migrated more than cemented cups at 12 and 24 months. Cemented cups had no measurable migration from 3 months’ follow-up, while cementless cups had not yet stabilized at 24 months in all rotations. Cementless cups showed statistically significantly more maximum total point motion (MTPM) at 12- and 24-month follow-up compared with cemented cups in patients with low systemic BMD (p = 0.01). Periprosthetic BMD changes did not statisticially significantly correlate to proximal migration in either cup fixation group (p > 0.05). PROMs improved similarly in both groups.Interpretation — Cemented cups were well fixed at 3 months. The cementless cups migrated more in patients with low BMD, showed an inconsistent pattern of migration, and migrated in different directions during the first and second year without tendency to stabilization. Cemented fixation of the Avantage DM cup seems safer in elderly patients

The most common indication for revision of a conventional primary total hip arthroplasty (THA) is aseptic loosening of the components (SHAR 2016, NJR 2017, DHAR 2018).Implant fixation method (i.e., cemented or cementless) in primary THA seems mainly based on the surgeon’s preference and national trends. The Danish Hip Replacement Registry report shows a decrease in the use of cemented cup fixation in osteoarthrosis (OA) patients above 70 years (DHAR 2018). This trend has also been described in the United Kingdom (UK) and Australian Joint Registries, while in Sweden and Norway cemented cup fixation is still the preferred fixation method in elderly patients (SHAR 2016, NAR 2017, NJR 2017).The dual-mobility (DM) concept, with 2 articulation surfaces and increased jump distance, may decrease the dislocation rate and increase range of motion compared with standard single mobility (SM) THAs. The long-term survival and the best fixation method of the newer Avantage Reload DM cup in elderly patients is currently unknown but retrospective studies on other types of primary DM THAs suggest acceptable survival rates (Batailler et al. 2017) .Excessive early (2-year) implant micromotion measured with radiostereometric analysis (RSA) is a strong predictor for later implant loosening and poor survival (Karrholm et al. 1997, Nieuwenhuijse et al. 2012, Pijls et al. 2012), and our primary aim was to investigate the early RSA-measured migration of cemented and cementless Avantage DM cups in elderly (> 70 years old) OA patients until 24 months’ follow-up. Secondary endpoints included systemic and periprosthetic bone mineral density (BMD) measurements, and clinical outcome scores.  相似文献   

7.
We studied prospectively 382 cementless (Zweymiiller stem) and hybrid (cemented stem) primary total hip replacements and used a cementless grit-blasted titanium alloy threaded cup. After a median 5 (0.2-12)-year follow-up, 1 cup was exchanged, 2 cups were removed for deep sepsis, and 3 cups showed definite loosening; of these, 2 subsequently required revision. Actuarial calculation methods indicated a 10-year survivorship of 99% with cup retrieval for any cause (clinical failure), definite cup-loosening (radiographic failure), and revision for aseptic cup-loosening as endpoints. These intermediate results exceed those from smooth-surfaced screw rings and compare favorably with those from cemented cups and cementless, press-fit, metal-backed cups.  相似文献   

8.
《Acta orthopaedica》2013,84(5):521-523
Background and purpose In a previous study based on the Finnish Arthroplasty Register, the survival of cementless stems was better than that of cemented stems in younger patients. However, the survival of cementless cups was poor due to osteolysis. In the present study, we analyzed population-based survival rates of the cemented and cementless total hip replacements in patients under the age of 55 years with primary osteoarthritis in Finland.

Patients and methods 3,668 implants fulfilled our inclusion criteria. The previous data included years 1980–2001, whereas the current study includes years 1987–2006. The implants were classified in 3 groups: (1) implants with a cementless, straight, proximally circumferentially porous-coated stem and a porous-coated press-fit cup (cementless group 1); (2) implants with a cementless, anatomic, proximally circumferentially porous-coated stem, with or without hydroxyapatite, and a porous-coated press-fit cup with or without hydroxyapatite (cementless group 2); and (3) a cemented stem combined with a cemented all-polyethylene cup (the cemented group). Analyses were performed separately for 2 time periods: those operated 1987–1996 and those operated 1997–2006.

Results The 15-year survival for any reason of cementless total hip replacement (THR) group 1 operated on 1987–1996 (62%; 95% CI: 57–67) and cementless group 2 (58%; CI: 52–66) operated on during the same time period was worse than that of cemented THRs (71%; CI: 62–80), although the difference was not statistically significant. The revision risk for aseptic loosening of cementless stem group 1 operated on 1987–1996 (0.49; CI: 0.32–0.74) was lower than that for aseptic loosening of cemented stems (p = 0.001).

Interpretation Excessive wear of the polyethylene liner resulted in numerous revisions of modular cementless cups. The outcomes of total hip arthroplasty appear to have been relatively unsatisfactory for younger patients in Finland.  相似文献   

9.
BackgroundPerforming total hip arthroplasty (THA) as early as possible is recommended for rapidly destructive coxarthrosis (RDC) as it causes pain that becomes progressively more severe. However, acetabular bone loss remains an issue in THA. Special devices, such as a Kerboull-type plate, may be used for acetabular bone defects, but the procedure is highly invasive and often the patients are elderly, further complicating matters. We retrospectively investigated the clinical and radiographic results of THA using conventional hydroxyapatite-coated cementless cup in RDC.MethodsA total of 32 patients (35 hips) with RDC were enrolled in the study with a minimum 10-year follow-up. All THAs were performed using conventional hydroxyapatite-coated cementless cup. All patients were evaluated clinically according to the Harris hip score (HHS). Acetabular bone deficiency was classified according to the American Academy of Orthopaedic Surgeons (AAOS) classification.ResultsEleven hips (31%) were AAOS type III, and none were type IV. Total HHS significantly improved from 36.5 to 79.4 (p < 0.01). Two cups exhibited loosening. The overall implant-associated survival rate after 10 years was 91.4%.ConclusionsClinical results of THA using conventional cementless implants for patients with RDC were acceptable. Thus, THA using conventional cementless implant is an effective and safe surgery for patients with RDC, minimizing surgical stress.  相似文献   

10.
《The Journal of arthroplasty》2023,38(6):1120-1125
BackgroundCemented dual mobility cups (DMCs) are commonly used in combination with acetabular reinforcement devices. Indeed, according to literature, direct cementation of metal-backed acetabular components into the bony acetabulum remains controversial as this technique is potentially associated with increased rates of aseptic loosening. Therefore, this study aimed to evaluate the clinical and radiographic outcomes of DMC cemented into the bony acetabulum in primary total hip arthroplasty (THA).MethodsA total of 49 THA (48 patients, mean age 78 years [range, 51 to 91]) performed with direct cementation of a DMC into the bony acetabulum were prospectively included in our total joint registry and retrospectively reviewed. The clinical outcome was assessed using the Harris hip score (HHS). The radiographic outcome included measurement of component positioning and occurrence and progression of demarcation around the cemented DMC. Complications were reported with a particular attention to cemented fixation failure and aseptic loosening.ResultsAt a 7-year mean follow-up (range, 5 to 8), the pre-to postoperative HHS improved from 47 (range, 30 to 58) to 92 points (range, 80 to 98) (P < .01). Nonprogressive and focalized demarcations were observed in 7 THA (14%). Importantly, no progressive demarcation or DMC aseptic loosening was observed.ConclusionDirect cementation of DMC into the bony acetabulum ensured a stable fixation with no progressive demarcation or aseptic loosening at midterm follow-up. Therefore, this technique can be selectively considered in primary THA, especially in elderly or frail patients to avoid potential mechanical failure of press-fit fixation due to altered bone quality or additional morbidity related to the use of acetabular reinforcement devices.  相似文献   

11.
《Acta orthopaedica》2013,84(6):566-571
Background and purpose Revision total hip arthroplasty (THA) due to recurrent dislocations is associated with a high risk of persistent instability. We hypothesized that the use of dual-mobility cups would reduce the risk of re-revision due to dislocation after revision THA.

Patients and methods 228 THA cup revisions (in 228 patients) performed due to recurrent dislocations and employing a specific dual-mobility cup (Avantage) were identified in the Swedish Hip Arthroplasty Register. Kaplan-Meier survival analysis was performed with re-revision due to dislocation as the primary endpoint and re-revision for any reason as the secondary endpoint. Cox regression models were fitted in order to calculate the influence of various covariates on the risk of re-revision.

Results 58 patients (25%) had been revised at least once prior to the index cup revision. The surgical approach at the index cup revision was lateral in 99 cases (44%) and posterior in 124 cases (56%). Median follow-up was 2 (0–6) years after the index cup revision, and by then 18 patients (8%) had been re-revised for any reason. Of these, 4 patients (2%) had been re-revised due to dislocation. Survival after 2 years with the endpoint revision of any component due to dislocation was 99% (95% CI: 97–100), and it was 93% (CI: 90–97) with the endpoint revision of any component for any reason. Risk factors for subsequent re-revision for any reason were age between 50–59 years at the time of the index cup revision (risk ratio (RR) = 5 when compared with age > 75, CI: 1–23) and previous revision surgery to the relevant joint (RR = 1.7 per previous revision, CI: 1–3).

Interpretation The risk of re-revision due to dislocation after insertion of dual-mobility cups during revision THA performed for recurrent dislocations appears to be low in the short term. Since most dislocations occur early after revision THA, we believe that this device adequately addresses the problem of recurrent instability. Younger age and prior hip revision surgery are risk factors for further revision surgery. However, problems such as potentially increased liner wear and subsequent aseptic loosening may be associated with the use of such devices in the long term.  相似文献   

12.
《Acta orthopaedica》2013,84(2):242-250
Background Revision total hip arthroplasty (THA) in patients with juvenile chronic arthritis (JCA) is complicated by the young age of the patient, poor bone stock and small physical proportions. We report the complications and outcome of a prospective series of 17 revision THAs in Charnley class C JCA patients.

Methods 15 acetabular components and 10 femoral components were revised. 13 cementless cups, 2 reconstruction/roof rings and cemented cups, and 4 cemented and 6 cementless femoral stems were implanted. 2 proximal femoral allografts and 1 strut allograft were used. Age at revision was 32 (21–53) years. Follow-up averaged 7 (4–12) years.

Results 2 patients with cemented femoral stems developed loosening, osteolysis and fracture. Both were successfully revised to long-stem cementless implants with strut/proximal femoral allografts. 1 loose, worn cementless cup with osteolysis was revised. 1 patient with a peri-operative infection and late acetabular fracture had a loose, non-revised cementless cup. 1 case of sciatic nerve palsy occurred after revision using a reconstruction ring. 1 late infection necessitated resection arthroplasty. Harris hip scores improved from 53 (34–85) to 76 (47–96).

Interpretation Revision THA in JCA has a substantial complication rate, even in experienced hands. The problem of obtaining long-term stable fixation, osteolysis, and replenishment of lost bone stock are major difficulties.  相似文献   

13.
Total hip arthroplasty (THA) with well designed cementless acetabular implants has shown excellent results. The purpose of this study was to assess our clinical and radiological outcomes using an uncemented cup. We conducted a prospective cohort study including all consecutive primary THAs performed with the Morscher press-fit cup, an uncemented non-modular acetabular component, between March 1996 and December 1998. Patients were evaluated at ten years with clinical and radiological follow-up, patient satisfaction and questionnaire assessment using the Harris hip score (HHS), Merle d’Aubigné and Postel score, the UCLA score, the 12-item short-form health survey (SF-12) and a visual analog scale. Five hundred sixty-one THAs were performed in 518 patients. At 120 months (± 7.3 months), 303 patients with 335 THAs were still available for follow-up. None of the patients had required cup revision for aseptic loosening. At ten years, the cup survivorship was 98.8% (95% CI 97.4–99.5) with cup revision for any cause as an endpoint. No radiolucencies were seen around the cups, but osteolytic defects involved 21 stems (8.3%). Mean total linear polyethylene wear was 0.9 mm. The Morscher acetabular replacement cup provides excellent results at ten years. There were no revisions for aseptic loosening of the cup, and no osteolytic defects were found around the cup. Patient satisfaction was high and the clinical results were very good.  相似文献   

14.
《The Journal of arthroplasty》2020,35(9):2561-2566
BackgroundDuring revision total hip arthroplasty (THA), the “double-socket” technique has been proposed as a straightforward solution in order to reduce the overall perioperative morbidity in patients with high surgical risk. However, the option of cementing a dual mobility cup into an existing well-fixed metal shell was sparsely reported. Therefore, this study aimed to evaluate the outcome of a “double-socket” technique performed with a cemented dual mobility cup in revision THA for late instability.MethodsTwenty-eight revision THAs (28 patients) were performed for wear-related recurrent dislocation using a “double-socket” technique with a cemented dual mobility cup and retrospectively reviewed. The age at revision averaged 82 years (range 74-93). According to the American Society of Anesthesiologists (ASA) physical status classification, 12 patients (43%) were ASA II and 16 patients (57%) were ASA III before revision.ResultsAt a mean follow-up of 3.5 years (range 2-5), the mean preoperative to postoperative functional outcome improved significantly (P < .01). The mean operative time was 107 minutes (range 75-140). The mean intraoperative bleeding was 200 mL (range 110-420). No postoperative complication, reoperation, or re-revision was reported. Importantly, no dislocation, dissociation of the cemented dual mobility cup construct, or aseptic loosening of the retained metal shell was observed.ConclusionThe “double-socket” technique with a dual mobility cup cemented into an existing well-fixed and well-positioned metal shell ensured a straightforward and blood-sparing revision technique that was efficient to restore stability and provide a secure acetabular construct in frail patients with high surgical risk and/or older than their natural life expectancy.  相似文献   

15.
BackgroundWe sought to evaluate the cause-specific revision risk following hybrid (cemented stem mated to a cementless acetabular implant) vs cementless total hip arthroplasty (THA) in a US cohort.MethodsPrimary elective THA for osteoarthritis was identified using Kaiser Permanente’s Total Joint Replacement Registry (2001-2018). Multivariable Cox regression was used to evaluate cause-specific revision, including aseptic loosening, infection, instability, and periprosthetic fracture (PPF), for hybrid vs cementless THA. Analysis was stratified by age (<65, 65-74, and ≥75 years) and gender.ResultsThe study cohort comprised 88,830 THAs, including 4539 (5.1%) hybrid THAs. In stratified analysis, hybrid THA had a higher revision risk for loosening in females in all 3 age subgroups. A lower risk of revision for PPF was observed following hybrid THA in females aged ≥75 years. For females ≥75 years, cementless THA had an excess PPF risk of 0.9% while hybrid THA had an excess loosening risk of 0.2%, translating to a theoretical prevention of 10 PPF revisions but a price of 3 loosening revisions per 1000 hybrid THAs. No difference in revision risk was observed in males.ConclusionWe observed differences in cause-specific revision risks by method of stem fixation which depended upon patient age and gender. Although the trend toward all cementless fixation continue, there may be a role for hybrid fixation in females ≥75 years to mitigate risk for revision due to PPF at the potential cost of a slight increase in longer term aseptic loosening.Level of EvidenceLevel III.  相似文献   

16.
BACKGROUND: The results of total hip arthroplasty (THA) in young patients with rheumatoid arthritis (RA) have been reported in only a few studies. On a nationwide level, the outcome of THA in these patients is unknown. We evaluated the population-based survival of THA in patients under 55 years of age with RA and factors affecting the survival. PATIENTS: Between 1980 and 2003, 2,557 primary THAs performed for RA in patients less than 55 years of age were reported to the Finnish Arthroplasty Register. RESULTS: Proximally circumferentially porous-coated uncemented stems had a 15-year survival rate of 89% (95% CI 83-94) with aseptic loosening as endpoint. The risk of stem revision due to aseptic loosening was higher with cemented stems than with proximally porouscoated uncemented stems implanted during the same period (RR 2.4; p < 0.001). In contrast, Cox regression analysis showed that the risk of cup revision was significantly higher for all uncemented cup concepts than for all-polyethylene cemented cups with any cup revision as endpoint. There were no significant differences in survival between the THR concepts. INTERPRETATIONS: Uncemented proximally circumferentially porous-coated stems and cemented all-poly-ethylene cups are currently the implants of choice for young patients with RA.  相似文献   

17.
BackgroundAlongside advances in total hip arthroplasty (THA), innovations in the treatment of cancer have led to an increasing number of patients living with this devastating disease. Radiation therapy has well-documented clinical effects on bone health, leading to pelvic insufficiency fractures and osteonecrosis of the femoral head. The purpose of this meta-analysis is to report on THA outcomes in this patient population in an effort to determine if a need to change management exists during surgical planning.MethodsFollowing the Preferred Reporting Items for Systematic Review and Meta-Analysis protocols, a systematic review of published literature through August 5th, 2018 was conducted. This resulted in 8 studies in which the primary outcome measures evaluated were rates of aseptic loosening and revision THA.ResultsAmong 232 hips at a weighted mean follow-up time of 52 months, the aseptic loosening rate was 10% and revision THA rate was 12%. Sub-analysis of 116 THAs with cementless cups demonstrated an aseptic loosening and revision THA rate of 8% and 10%, respectively.ConclusionThe findings of the present study indicate that THA recipients who have received radiation therapy to the pelvis before arthroplasty surgery have higher rates of aseptic loosening and revision THA when compared with previously published rates in healthy THA recipients. Additionally, it is possible that female THA recipients who have received pelvic irradiation may be at a higher risk for aseptic loosening and revision THA. Surgeons should counsel patients with a history of pelvic irradiation about their potentially higher risk for these complications.Level of EvidenceLevel I, meta-analysis, and systematic review.  相似文献   

18.
19.
Background and purpose — Uncemented cups in total hip arthroplasty (THA) are often augmented with additional screws to enhance their primary stability. We investigated whether there is a difference in the risk for revision between cups with screw holes and cups without screw holes.

Patients and methods — We analyzed the risk for cup revision of uncemented cups registered in the Swedish Hip Arthroplasty Register (SHAR) between 2000 and 2017 with respe ct to the presence of screw holes. Only patients with primary osteoarthritis (OA) were included. 22,725 cups, including 12,354 without screw holes and 10,371 with screw holes, were evaluated. Revision rates at 2 and 10 years after the primary operation were analyzed.

Results — At a median follow-up time of 3.4 years (0–18), 459?cup revisions were reported. The main reasons for cup revision during the whole observation time were infection, 52% of all cup revisions, and dislocation, 26% of all cup revisions. The survival rate with cup revision due to aseptic loosening as endpoint was 99.9% (95% CI 99.8–99.9) at 2 years for both cups with and cups without screw holes, and the survival rates at 10 years were 99.5% (CI 99.3–99.7) and 99.1% (CI 98.6–99.5), respectively. Cups without screw holes showed a decreased risk of revision due to any reason at both 2 years (adjusted hazard ratio [HR] 0.6, CI 0.5–0.8) and 10 years (HR 0.7, CI 0.5–0.9).

Interpretation — We found a very low revision rate for aseptic loosening with modern, uncemented cup designs. Cups with screw holes had an increased risk of revision due to any reason in patients with primary OA  相似文献   

20.
BackgroundRevision of a failed total hip arthroplasty (THA) poses technical challenges. The use of primary stems for revision can be advantageous for maintaining bone stock and reducing complications: small case series have reported promising results in the short-term to mid-term follow-up. The aim of this study was to evaluate the long-term clinical and functional results and survivorship of a consecutive series of THA femoral component revisions using a conical primary cementless stem (PCS).MethodsNinety-four stem revisions with a preoperative Paprosky I or II defect were analyzed at an average follow-up of 12.7 ± 5.4 years. Aseptic loosening was the reason for revision in 92.5% of cases. Twenty patients were lost to follow-up. Two subgroups were created: Group 1 (n = 59) underwent isolated stem revision; Group 2 (n = 15) underwent complete THA revision. All were evaluated preoperatively and postoperatively based on the Harris Hip Score (HHS), the Western Ontario and McMaster Universities Index (WOMAC) score, and the visual analog scale for pain (VAS). Residual trochanteric pain and length discrepancies were recorded. Radiographic evaluation included signs of osteolysis, subsidence, loosening, and heterotopic ossification.ResultsPCS survivorship was 100% at 5 years and 95.9% at 10 years. Overall, significant postoperative improvements (P < .01) were observed on the HHS (44.3 vs 86.9), WOMAC (42.8 vs 82.8), and VAS (7.0 vs 3.0). Postoperative scores on all scales were higher for Group 1 (P < .01). Three patients (4.1%) underwent further stem revision. Demarcation lines (1 mm) were found in 12 (16.2%) patients and significant heterotopic ossifications in 22 (29.7%).ConclusionThe use of PCS for stem revision in failed THA with a limited femoral bone defect is a reliable option for both isolated stem revision and concomitant cup revision in well-selected patients.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号