首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Introduction and ObjectivesChronic rhinitis-related complaints may result from isolated hypertrophy of the inferior nasal turbinates. If the symptoms persist despite conservative management, turbinoplasty is indicated. However, the nasal mucosa lining the inferior turbinates seems decongested immediately before the surgery performed under local anaesthesia, compared to the examination when the patients were entered for surgery. The study aimed to confirm this observation and to hypothesize as to the reasons for its occurrence.Patients and MethodsThe measurements of the longest distances between the medial rim of the inferior nasal turbinate mucosa and nasal septum and the shortest distances between the lower rim of the turbinate and floor of the nasal cavity in the inferior part of both common nasal meatus, were carried out on photos taken during endoscopic examinations: the one entering the patient for turbinoplasty, and the other immediately before the procedure. The results in this group were compared to those obtained from patients operated on under general anaesthesia.ResultsIn 130 patients aged 18-60 (mean = 40.7) years, operated on under local anaesthesia, the sum of the mean distances between the nasal septum and the medial rim of the lower turbinate in both nasal cavities, was 3.4 mm during the first examination, and 4.5 mm (p = .0008) during the second one. In the group of 42 participants aged 26-47, mean = 36.8 years operated on under general anaesthesia, the values were: 4.8 mm and 3.6 mm (p = .02), respectively. The differences were significantly smaller in the smokers (.3) compared to non-smokers (1.3; p = .04) mm.ConclusionsRecords of the entering examination must be considered before turbinoplasty under local anaesthesia.  相似文献   

2.
ObjectivesIn the past few years, virtual planning has been increasingly used for mandibular reconstruction. The objective of our study was to evaluate and compare symmetry and the accuracy of morphologic reconstruction in patients undergoing mandibular reconstruction by fibular free flap between traditional freehand technique and computer-aided surgical cutting guides.Material and methodsA single-center retrospective study included all cases of mandibular reconstruction using fibular free flap. In the three-dimensional (3D) group, virtual surgery planning with cut guides was used (Materialise ®), while the Control group underwent traditional freehand reconstruction. Morphometric comparisons were made to evaluate reconstruction accuracy between pre- and post-operative CT scans (mean deviations of 3 angles and 3 lengths). Mandible symmetry was calculated by comparing each angle and length in the affected and non-affected sides of the mandible.ResultsThirty-three patients treated between January 2015 and June 2018 were included: 25 patients in the 3D group and 8 in the control group. The average number of mandibular segments was 2.16 ± 0.55 in the 3D group and 1.75 ± 1.16 in the control group (p = 0.005). Mean deviations between pre- and post-operative values of the coronal mandibular angle (angle formed by the line through the two condyles and the ramus), mandibular body height and mandibular ramus length on the affected side were significantly lower in the 3D group than in the control group. Sagittal mandibular angle symmetry was better in the 3D group than, in the control group (ratios of affected over non-affected sides: 1.07 ± 0.04 vs 1.12 ± 0.1; p = 0.034).ConclusionVirtual surgical planning for fibula free-flap reconstruction helps to improve reconstruction accuracy and maintains a significantly greater symmetry than the traditional freehand technique, and should improve functional and esthetic outcome in mandibular reconstruction.  相似文献   

3.
ObjectivesSurgical treatment of temporo-sphenoidal meningoceles involves the reduction of the meningocele, watertight closure and defect coverage with a nasoseptal flap (NSF). It can be performed contralaterally or ipsilaterally: in the latter situation, the pedicle of the flap must be dissected into the pterygopalatine fossa. The objective of this study was to evaluate the benefit of using an ipsilateral NSF in transpterygoid approaches for the management of temporo-sphenoidal meningoceles, compared to a contralateral NSF, based on a radiological study.Material and methodsRetrospective monocentric study of 21 cases, between 2002 and 2018. Measurement of the NSF lengths, and lengths needed to cover the defect were evaluated on the preoperative scanner. Early and later failure and complication rates were evaluated.ResultsSeventeen cases of temporo-sphenoidal meningoceles with available CT scan were identified. The mean duration of follow up was 27.9 months [1–147]. Theoretical lengths of the ipsi and contralateral NSF were comparable: 71.4 ± 7.8 mm vs. 78.8 ± 8 mm, P = 0.729. In 8 cases/18 (42%), the theoretical length of the contralateral NSF was not long enough to cover the defect beyond the V2 (mean lack of 8.87 ± 6.6 mm). In all cases, the theoretical length of the ipsilateral NSF was sufficient to cover the defect. In the case series, failure and complication rates were similar.ConclusionThe use of an ipsilateral NSF for the transpterygoid management of temporo-sphenoidal meningoceles, although more complex, allows a better coverage of the defect, compared to the contralateral NSF, which is not long enough in 42% of cases.  相似文献   

4.
ObjectiveTo determine the circadian influence on sound sensitivity produced by temporal hearing deprivation in healthy normal human subjects.DesignParticipants underwent bilateral earplugging before completion of anthropometry, the author's developed questionnaire, the Hamilton Anxiety and Depression Inventory, pure tone audiometry (PTA), stapedial reflex thresholds (SRT), distortion products otoacoustic emissions input/output (DPOAE-I/O), and uncomfortable loudness levels (ULLs). Afterward, the participants were randomly divided into group A, starting at 8:00 a.m. and finishing at 8:00 p.m., and group B, starting at 4:00 p.m. and ending at 4:00 a.m. Serum cortisol levels and audiological test results were obtained at the beginning and end of the session and 24-h free urinary cortisol levels were measured.Study sampleThirty healthy volunteers.ResultsPTA was 2.68 and 3.33 dB HL in groups A and B, respectively, with no statistical difference between them. ULLs were significantly lower in group A compared to group B, with an average of 8.1 dB SPL in group A and 3.3 dB SPL in group B (p < 0.0001). A SRT shift was observed in group A, with no difference in group B, and a night shift in DPOAE-I/O in group B.ConclusionsReduced loudness tolerance is demonstrated during daytime hearing deprivation in contrast to nighttime; this may be due to increased central gain in the awake cortex.  相似文献   

5.
The skull vibration-induced nystagmus test (SVINT) is a global vestibular test stimulating otoliths and semicircular canals at a frequency of 100 Hz, not modified by vestibular compensation, which may reveal vibration-induced nystagmus (VIN). Bone-conducted vibration applied to the mastoid processes and the vertex instantaneously induces predominantly low-velocity (∼10°/s) horizontal nystagmus, with rapid phases beating away from the affected side in patients with unilateral vestibular loss (UVL). VIN starts and stops immediately with stimulation, is continuous, reproducible, beats in the same direction irrespective of which mastoid process is stimulated, with no or little habituation. The SVINT acts like a vestibular Weber test. In peripheral UVL, the SVINT is a good marker of vestibular asymmetry and demonstrates pathological nystagmus beating towards the healthy side in 90% of cases of vestibular neuritis, 71% of cases of Menière's diseases and 44 to 78% of vestibular schwannomas. In superior semicircular canal dehiscence, VIN usually beats towards the affected side due to facilitation of bone conduction related to the presence of a third window. Stimulation of the vertex is more effective than in UVL patients, with sensitivity extending to higher frequencies, up to 700 Hz. Observation of vibration-induced nystagmus then reveals equally represented vertical, torsional, and horizontal components beating towards the affected ear, suggesting dominant, but not exclusive, stimulation of the dehiscent superior semicircular canal.  相似文献   

6.
IntroductionPyogenic spondylodiscitis is a rare, destructive intervertebral disc infection.Case summaryWe describe a case of C2-C3 pyogenic spondylodiscitis after transoral surgery of the posterior pharyngeal wall in a 64-year-old man with a history of oropharyngeal squamous cell carcinoma (SCC) treated by neck irradiation (45 Gy). Ten years after initial treatment, he underwent total laryngectomy for laryngeal SCC, together with transoral resection of carcinoma in situ (CIS) of the posterior pharyngeal wall followed by BioDesign® tissue repair graft. Five months later, C2-C3 spondylodiscitis was diagnosed with the formation of a fistula between the posterior pharyngeal wall and the intervertebral disc. Antibiotic therapy was administered for a total duration of 3 months (multi-susceptible Escherichia coli). Eight months after the diagnosis of spondylodiscitis, the patient died from carotid artery rupture following another course of radiotherapy for lymph node recurrence.DiscussionLarger-scale studies are necessary to evaluate the prevalence and risk factors of radiation-induced spondylodiscitis that currently remain poorly elucidated. The best treatment strategy (choice and duration of antibiotic therapy) and the optimal frequency of follow-up must be determined and the value of preventive measures (biomaterial, flap repair) needs to be evaluated.  相似文献   

7.
Objectiveto study the effects on vestibulo-ocular reflex (VOR) gain using both video head impulse test (vHIT) and Suppression Head impulse test (SHIMP) either using the outward or the inwards head impulse.MethodsTwenty healthy subjects were enrolled in the study. They were examined using otometric vHIT and SHIMP test lateral plane using the lateral outwards head impulse ten impulses for each side and the inwards head impulse ten impulses for each side. The VOR gain resulting from the outwards versus inwards head impulse during the vHIT and SHIMP were statistically compared.ResultsTwenty healthy subjects, 10 Males and 10 females with a mean age 35 ± 11.7. Paired t- test showed no statistical significance difference in the mean VOR gain of right lateral semicircular canal (1.1 ± .12) using outwards versus (1.03 ± .22) inwards head impulses, nor for the left lateral semicircular canal mean VOR gain (1.1 ± .22) using outwards head impulse (1.1 ± .3) for inwards head impulse in vHIT. Paired t- test showed no statistical significance difference in the mean VOR gain of right lateral semicircular canal (0.96 ± 0.2)using outwards versus (1.04 ± 0.2) inwards head impulses, nor for the left lateral semicircular canal mean VOR gain (0.98 ± 0.25) using outwards head impulse (1.1 ± 0.28) for inwards head impulse in SHIMP test. No statistical significant difference was found between the VOR gain resulting from the right versus the left semicircular canal.ConclusionThe starting head position does not affect the VOR gain using both vHIT and SHIMP tests.  相似文献   

8.
ObjectiveScoping review of published literature to establish clinical characteristics and audiologic outcomes in patients diagnosed with Susac’s Syndrome(SS) who have undergone cochlear implantation (CI).Data sourcesAll published studies of CI in SS and contribution of two of our own patients who have not been reported previously.MethodsA comprehensive search of MEDLINE (via PubMed) was carried out in March 2020 using the following keywords and related entry terms: Susac’s Syndrome, Cochlear Implantation.ResultsOur search identified a total of five case reports of CI in SS. With the addition of our two patients reported here, we analyzed characteristics and outcomes in seven patients. Mean age at implantation was 30 years old (range 19–46), with six women and one man implanted. Mean time from onset of hearing loss to implantation was 17 months (range three months to four years). Best reported postoperative speech understanding was reported via different metrics, with six of seven patients achieving open set speech scores of 90% or better, and one subject performing at 68%. Vestibular symptoms were present preoperatively in four of seven patients (57%), with vestibular testing reported in two patients, and showing vestibulopathy in one patient. No complications were reported following cochlear implantation.ConclusionCochlear implantation is a viable option for hearing rehabilitation in patients with SS, with levels of attainment of open set speech comparable to other populations of CI candidates.  相似文献   

9.
Background and objectiveOsseointegrated auditory devices are hearing gadgets that use the bone conduction of sound to produce hearing improvement. The mechanisms and factors that contribute to this sound transmission have been widely studied, however, there are other aspects that remain unknown, for instance, the influence of the processor power output. The aim of this study was to know if there is any relationship between the power output created by the devices and the hearing improvement that they achieve.Materials and methodsForty-four patients were implanted with a percutaneous Baha® 5 model. Hearing thresholds in pure tone audiometry, free-field audiometry, and speech recognition (in quiet and in noise) were measured pre and postoperatively in each patient .The direct bone conduction thresholds and the power output values from the processors were also obtained.ResultsThe pure tone average threshold in free field was 39.29 dB (SD 9.15), so that the mean gain was 29.18 dB (SD 10.13) with the device. This involved an air-bone gap closure in 63.64% of patients. The pure tone average threshold in direct bone conduction was 27.6 dB (SD 10.91), which was 8.4 dB better than the pure tone average threshold via bone conduction. The mean gain in speech recognition was 39.15% (SD 23.98) at 40 dB and 36.66% (SD 26.76) at 60 dB. The mean gain in the signal-to-noise ratio was ?5.9 dB (SD 4.32). On the other hand, the mean power output values were 27.95 dB μN (SD 6.51) in G40 and 26.22 dB μN (SD 6.49) in G60. When analysing the relationship between bone conduction thresholds and G40 and G60 values, a correlation from the frequency of 1,000 Hz was observed. However, no statistically significant association between power output, functional gain or speech recognition gain was found.ConclusionsThe osseointegrated auditory devices generate hearing improvement in tonal thresholds and speech recognition, even in noise. Most patients closed the air-bone gap with the device. There is a direct relationship between the bone conduction threshold and the power output values from the processor, but only in mid and high frequencies. However, the relationship between power output and gain in speech recognition is weaker. Further investigation of contributing factors is necessary.  相似文献   

10.
ObjectiveUnstable cavities are defined as cavities with cerumen accumulation that need frequent cavity cleaning in the out-patient clinic, cavities that are intolerant to water due to risk of infection or that are subject to frequent infection and otorrhoea. The objective of this study is to address the problem of troublesome mastoid cavities, with the performance of secondary mastoid obliteration and canal wall reconstruction, using a novel posterior auricular artery (PAA) fascia-periosteum flap.Materials and methodsA prospective study was designed, only secondary obliterations were included. Unstable mastoid cavities were defined as Merchant grade 2 or 3 and were included for surgery.ResultsAt 12 months of follow up, a complete external auditory canal (EAC) and a self-cleaning ear were achieved in all 23 patients. Completely dry ears were achieved in 21 patients (91.3%). An air-bone gap improvement of 5 dB was achieved.ConclusionMastoid obliteration and EAC reconstruction are effective procedures to treat troublesome post canal wall down mastoid cavities. They improve quality of life and enable patients to overcome ear discharge. A standard EAC size enables the utilization of conventional hearing aids, it also reduces the need for constant mastoid cleaning and decreases healthcare expenses. The PAA flap seems to be an effective procedure to achieve all these features, as it is used to obliterate the mastoid and becomes a structural component of the neo-EAC.  相似文献   

11.
12.
Introduction and objectivesThe contralateral occlusion test (COT) has the potential to allow the quantitative evaluation of unilateral conductive hearing loss. The purpose of this study was to determine the accuracy of the test in predicting the degree of hearing loss.Materials and methodsFifty-three subjects with unilateral conductive hearing loss were recruited from an otolaryngology department of a tertiary hospital. The COT was performed using 128, 256, 512, 1024 and 2048 Hz tuning forks with the non-affected ear canal totally occluded to determine lateralization. Pure-tone audiometry was performed to establish the presence and degree of the air-bone gap (ABG) and the pure-tone average (PTA). The tuning fork responses were correlated with the ABG and the PTA to determine their accuracy.ResultsThe COT showed a better association between hearing loss and the lateralization response using the 512 Hz tuning fork (p = 0.001). The sensitivity of the 512 Hz fork in detecting a PTA of at least 35.6 dB was 94.6% and the specificity was 75.0% for a positive predictive value of 89.7% and a negative predictive value of 85.7%, assuming a pretest prevalence of 69.8%.ConclusionsThe overall accuracy of the COT in predicting the degree of unilateral conductive hearing loss was significant. The COT had significant power in one direction: if lateralization to the affected ear occurred, it was almost certain evidence of a moderate or severe conductive hearing loss.  相似文献   

13.
ObjectivesThe main goal of the present study was to assess hearing outcome for malleus removal in cholesteatoma surgery compared to a group with malleus conservation. The secondary aim was to compare the auditory involvement of the stapes between the two groups.Material and methodsA single-center observational study included adult patients operated on by ossiculoplasty for acquired cholesteatoma between 2015 and 2019. Endpoints comprised improvement in pure-tone average air-bone gap (PTA-ABG) and air-bone gap (ABG) at conversational frequencies and, independently, per frequency. 136 patients were included: 95 with conserved malleus (M+) and 41 with malleus removal (M(). Mean time to audiometric follow-up was 9 months in both groups.ResultsThe PTA-ABG improvement was 4.4 ± 12.6 dB for the M+ group and 3.8 ± 13.4 dB for the M? group, with no significant significance (P = 0.8). Better results (not exceeding 7.5 dB) were found for the M+ group at 2 and 8 kHz (P = 0.3 and P = 0.052 respectively). Presence or absence of the stapes did not affect the results in either group.ConclusionThose results suggest a negligible role of the malleus in early hearing outcome of tympanoplasty for cholesteatoma. A slight improvement was observed in the M+ group at 2 and 8 kHz, but its interpretation remains uncertain.  相似文献   

14.

Objective

The active transcutaneous bone conduction implant Bonebridge®, is indicated for patients affected by bilateral conductive/mixed hearing loss or unilateral sensorineural hearing loss, showing hearing outcomes similar to other percutaneous bone conduction implants, but with a lower rate of complications. The aim of this study was to analyze the hearing outcomes in a series of 26 patients affected by conductive or mixed hearing loss and treated with Bonebridge®.

Methods

26 of 30 patients implanted with Bonebridge® between October 2012 and May 2017, were included in the study. We compared the air conduction thresholds at the frequencies 500, 1000, 2000, 3000, 4000 Hz, the SRT50% and the percentage of correct answers at an intensity of 50 dB with and without the implant.

Results

“Pure tone average” with the implant was 34.91 dB showing an average gain of 33.46 dB. Average SRT 50% with the implant was 34.33 dB, whereas before the surgery no patient achieved 50% of correct answers at a sound intensity of 50 dB. The percentage of correct answers at 50 dB changed from 11% without the implant to 85% with it. We only observed one complication consisting of an extrusion of the implant in a patient with a history of 2 previous rhytidectomies.

Conclusions

The hearing outcomes obtained in our study are similar to those published in the literature. Bonebridge® represents an excellent alternative in the treatment of conductive or mixed hearing loss, and with a lower rate of complications.  相似文献   

15.
IntroductionThe goal of ossiculoplasty is to improve hearing and the success of this procedure depends on several factors.ObjectiveAnalyze the hearing results in patients with chronic otitis media undergoing ossicular chain reconstruction, as well as predictive factors for successful surgery.MethodsCharts of patients undergoing ossiculoplasty between 2006 and 2016 were reviewed. Sixty-eight patients were included, totaling 72 ears. The following data was analyzed: gender, age, smoking status, laterality, pathology, audiometric exams, type of surgery, previous surgery, characteristics of the middle ear, otorrhea and ossicular chain status. Patients were also classified according to two indices: middle ear risk index and ossiculoplasty outcome parameter staging. The results were evaluated by comparing the air-bone gap before and after surgery. The success of reconstruction was defined as air-bone gap ≤20 dB and the improvement of speech reception Thresholds, calculated through the mean frequencies 0.5, 1, 2 and 3 kHz.ResultsReconstruction success rate was 61%. The mean preoperative air bone gap was 34.63 dB and decreased to 17.26 dB after surgery. There was a correlation between low risk in middle ear risk index and ossiculoplasty outcome parameter staging indices with postoperative success. The most frequently eroded ossicle was the incus and the type of prosthesis most used was tragal cartilage. In the patients without incus, we achieved success in 74.2% of the surgeries. In the absence of the stapes, the success rate decreased to 63.3%. In the absence of the malleus, 85% of the patients had and air bone gap ≤20 dB.ConclusionWe achieved good audiometric outcomes in ossiculoplasty and the results are comparable to other centers. Ossicle status influenced postoperative results, especially in the presence of stapes. We also concluded that the indexes analyzed may help to predict the success of the surgery.  相似文献   

16.
ObjectiveTo assess ossiculoplasty results in children and screen for predictive factors of efficacy.Patients and methodsSeventy five children undergoing ossiculoplasty between 2001 and 2014 in a pediatric ENT department were included. The following data were collected and analyzed: demographic data, surgical indication, history of tympanoplasty, contralateral ear status (healthy, affected), preoperative hearing thresholds, surgical technique, intraoperative findings, and ossicular chain status at eardrum opening. Audiological results were reported according to American Academy of Otolaryngology-Head and Neck Surgery guidelines.ResultsForty eight patients were included in the total ossicular reconstruction prosthesis (TORP) group. Mean age at surgery was 9.9 years. Mean follow up was 2.7 years. Mean air-bone gap (ABG) closure to within 20 dB was achieved in 40% of cases at medium term (12 to 18 months after surgery). Air conduction (AC) threshold ≤ 30 dB was achieved in 68% of cases. AC threshold improved by 14.6 dB and 8.7 dB at medium and long-term follow-up, respectively. A significant correlation was found between success rate and absence of history of tympanoplasty. The success rate was higher for primary than for revision procedures. Twenty seven children were included in the partial ossicular reconstruction prosthesis (PORP) group. Mean age was 9.5 years, and mean follow-up 2.6 years. Mean air-bone gap (ABG) closure to within 20 dB was achieved in 75% of cases at medium term. AC threshold ≤ 30 dB was achieved in 75% of cases AC threshold improved by 9.3 dB and 5 dB at medium and long-term follow-up, respectively. No predictive factors for success were found in the PORP group.ConclusionThe present study suggested that total ossiculoplasty leads to better results when performed in first-line. It also confirmed that functional outcome is better in partial than total ossicular reconstruction prosthesis.  相似文献   

17.

Objectives

To analyze the etiologies, auditory consequences, diagnostic tools and therapeutic results of three often confused pathologies: acquired fibrous stenosis of the medial part of the external auditory canal (EAC), fibrous anterior tympanomeatal angle blunting, and lateralized tympanic membrane.

Material and methods

Retrospective study of 18 cases operated on over a 16-year period (14 patients: 7 female, 7 male; aged 11–64 years): 8 cases of medial EAC stenosis, 3 of blunting, and 7 of tympanic membrane lateralization.

Results

In all 3 pathologies, otoscopic and radiologic diagnosis was easily established, so that they could not be confused. All 3 induced > 33 dB conductive hearing loss. Medial EAC stenosis was secondary to chronic inflammation of the EAC, aggravated by surgery in 5 cases. Blunting was secondary to surgery altering the anterior tympanic annulus. Tympanic membrane lateralization was secondary to prior surgery without inflammatory process. Underlying EAC cholesteatoma was found in 3 cases of medial stenosis and in 1 case of blunting. Surgical results were disappointing in medial stenosis, with 62.5% recurrence and mean functional gain of 9 dB, and in blunting, with 66.7% recurrence and mean functional gain of 6 dB; auditory results were, however, good in these 2 pathologies when there was no recurrence of fibrosis. Results were significantly better in lateralized tympanic membrane, with 28.6% recurrence and mean functional gain of 16 dB.

Conclusion

The good results obtained in tympanic membrane lateralization seem to justify surgery in patients bothered by their hearing loss. The indication is more questionable in cases of medial fibrous stenosis and blunting, although significant auditory improvement is achieved in case of surgical success.  相似文献   

18.
PurposeTo compare cartilage tympanoplasty (CT) combined with eustachian tube balloon dilatation (ETBD) and cartilage tympanoplasty alone as a surgical treatment modality for adhesive otitis media (AdOM) in terms of graft healing, audiological outcomes, and impact on life style, using Chronic Otitis Media Outcome Test 15 (COMOT-15).Methods50 patients with AdOM were randomly classified into 2 groups: 25 patients for cartilage tympanoplasty only (CT group) and 25 patients for cartilage tympanoplasty combined with eustachian tube balloon dilatation (CT + ETBD group). Clinical outcomes in both groups were compared at 3 and 6 months of follow up.ResultsThere was no significant difference in graft healing between the two groups. Postoperative COMOT-15 scores significantly decreased in both groups with a significant difference between the groups with regard to the decrease in COMOT-15 scores at 3 and 6 months of follow-up (P < 0.05). Hearing improvement was achieved, as the mean preoperative ABG was 26.5 ± 5.4 and 27.1 ± 4.6 dB, and the mean postoperative ABG at 6 months was 19.4 ± 4.4 and 14.6 ± 3.9 dB in the CT and the CT + ETBD groups, respectively. The difference in the magnitude of ABG reduction in the two groups was significant at 3 and 6 months of postoperative follow-up (P < 0.05) in favour of the CT + ETBD group.ConclusionETBD can increase the success rate of cartilage tympanoplasty in patients with AdOM by enhancing the audiological outcome and quality of life.  相似文献   

19.
《Auris, nasus, larynx》2023,50(5):714-719
ObjectiveIntratympanic steroid injection (ITSI) can be an effective treatment for sudden sensorineural hearing loss or Meniere's disease. Tympanic membrane (TM) perforation after ITSI is a major complication which needs additional treatment. The purpose of this study is to assess the factors associated with TM perforation after ITSI.MethodsWe obtained the clinical data of patients who underwent ITSI treatment at the Department of Otolaryngology JR Tokyo General Hospital from April 2013 to March 2021. The data included age, sex, treated side, number of injections, average interval between injections, TM anesthesia with Zentöl solution, which contains phenol, any history of diabetes and any concurrent use of oral or intravenous steroids. We evaluated the association between these variables and TM perforation after ITSI using the Student's t-test, the chi-squared test, univariate logistic regression analysis and multivariate logistic regression analysis. TM perforation was defined as a case in which perforation was observed at least once during outpatient visits.ResultsRecords of 205 ears in 190 patients were analyzed. The overall proportion of TM perforation in the early period after ITSI was 12.7% (26 out of 205 ears), which decreased to 9.3% (19 out of 205 ears) and 5.9% (12 out of 205 ears) at the 1- and 3-month follow-ups, respectively. The proportion of TM perforation in the early period after ITSI without TM anesthesia was 3.5% (5 ears out of 145 ears), which decreased to 1.4% (2 ears) or 0% at the 1- or 3- month follow-ups, respectively. The use of tympanic anesthetics which contain phenol was significantly associated with TM perforation in univariate logistic regression analysis (odds ratio: 15.08, 95% confidence interval: 5.34–42.56, p < 0.001) and in multivariate analysis (odds ratio: 20.76, 95% confidence interval: 6.31–68.3, p < 0.001). All TM perforation cases without TM anesthesia healed spontaneously or with paper tympanic closure treatment. TM perforation in 6 ears out of 21 ears with TM anesthesia did not heal during the follow-up.ConclusionThe overall proportion of TM perforations from the early period after ITSI was 12.7%, 9.3% at the 1-month post-ITSI outpatient follow-up, 5.9% at the 3-month post-ITSI outpatient follow-up. Tympanic anesthesia was significantly associated with TM perforation after ITSI, which indicated that TM anesthesia with solutions containing phenol is not recommended for ITSI.  相似文献   

20.
《Auris, nasus, larynx》2023,50(2):212-217
ObjectiveTo investigate the feasibility of a deep learning method based on a UNETR model for fully automatic segmentation of the cochlea in temporal bone CT images.MethodsThe normal temporal bone CTs of 77 patients were used in 3D U-Net and UNETR model automatic cochlear segmentation. Tests were performed on two types of CT datasets and cochlear deformity datasets.ResultsThrough training the UNETR model, when batch_size=1, the Dice coefficient of the normal cochlear test set was 0.92, which was higher than that of the 3D U-Net model; on the GE 256 CT, SE-DS CT and Cochlear Deformity CT dataset tests, the Dice coefficients were 0.91, 0.93, 0 93, respectively.ConclusionAccording to the anatomical characteristics of the temporal bone, the use of the UNETR model can achieve fully automatic segmentation of the cochlea and obtain an accuracy close to manual segmentation. This method is feasible and has high accuracy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号