首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 27 毫秒
1.
BackgroundRevision of a failed total hip arthroplasty (THA) poses technical challenges. The use of primary stems for revision can be advantageous for maintaining bone stock and reducing complications: small case series have reported promising results in the short-term to mid-term follow-up. The aim of this study was to evaluate the long-term clinical and functional results and survivorship of a consecutive series of THA femoral component revisions using a conical primary cementless stem (PCS).MethodsNinety-four stem revisions with a preoperative Paprosky I or II defect were analyzed at an average follow-up of 12.7 ± 5.4 years. Aseptic loosening was the reason for revision in 92.5% of cases. Twenty patients were lost to follow-up. Two subgroups were created: Group 1 (n = 59) underwent isolated stem revision; Group 2 (n = 15) underwent complete THA revision. All were evaluated preoperatively and postoperatively based on the Harris Hip Score (HHS), the Western Ontario and McMaster Universities Index (WOMAC) score, and the visual analog scale for pain (VAS). Residual trochanteric pain and length discrepancies were recorded. Radiographic evaluation included signs of osteolysis, subsidence, loosening, and heterotopic ossification.ResultsPCS survivorship was 100% at 5 years and 95.9% at 10 years. Overall, significant postoperative improvements (P < .01) were observed on the HHS (44.3 vs 86.9), WOMAC (42.8 vs 82.8), and VAS (7.0 vs 3.0). Postoperative scores on all scales were higher for Group 1 (P < .01). Three patients (4.1%) underwent further stem revision. Demarcation lines (1 mm) were found in 12 (16.2%) patients and significant heterotopic ossifications in 22 (29.7%).ConclusionThe use of PCS for stem revision in failed THA with a limited femoral bone defect is a reliable option for both isolated stem revision and concomitant cup revision in well-selected patients.  相似文献   

2.
《The Journal of arthroplasty》2022,37(12):2420-2426
BackgroundTapered modular stems are increasingly used in revision total hip arthroplasty (THA) with deficient femoral bone stock. This study aimed to report the long-term outcomes of revision THA using a tapered and fluted modular stem.MethodsBetween December 1998 and February 2006, 113 revision THAs (110 patients) were performed with a tapered and fluted modular stem at a single institution. Hip radiographs were used to identify stem subsidence, stability, and femoral radiolucency. Final outcomes were assessed in 72 hips (70 patients), with a minimum follow-up of 10 years.ResultsThe mean follow-up duration was 16 years (range, 10-23). At the final evaluation, the Harris Hip Score improved from a mean of 41 points (range, 10-72) preoperatively to 83 points (range, 56-100) (P < .001). Six femoral re-revisions were performed for the following reasons: 1 aseptic loosening, 2 stem fractures, and 3 infections. One stem fracture occurred at the modular junction after 14 years, and the other at a more distal location after 15 years. Stem subsidence was >5 mm in 6 hips (9.1%), but secondary stability was achieved in all stems. Osseointegration was observed in 63 (95.5%) hips. Stem survivorship was 91.1% with an end point of any re-revision and 94.6% for aseptic re-revision.ConclusionA tapered and fluted modular stem demonstrated excellent implant survivorship with reliable bony fixation at a mean follow-up of 16 years. This type of stem can be a durable option for revision THA in patients who have femoral defects.  相似文献   

3.
BackgroundPeriacetabular osteotomy (PAO) is a well-accepted treatment for acetabular dysplasia, but treatment success is not uniform. Concurrent hip arthroscopy has been proposed for select patients to address intraarticular abnormalities. The patient-reported outcomes, complications, and reoperations for concurrent arthroscopy and PAO to treat acetabular dysplasia remain unclear.Questions/purposes(1) What are the functional outcome scores among select patients treated with PAO plus concurrent hip arthroscopy at mid-term follow-up? (2) What factors are associated with conversion to THA or persistent symptoms (modified Harris hip score ≤ 70 or WOMAC pain subscore ≥ 10)? (3) What proportion of patients underwent further hip preservation surgery at mid-term follow-up? (4) What are the complications associated with the procedure?MethodsBetween November 2005 and December 2012, 78 patients (81 hips) who presented with symptomatic acetabular dysplasia—defined as a lateral center-edge angle less than 20° with hip pain for more than 3 months that interfered with daily function—had undergone unsuccessful nonsurgical treatment, had associated intraarticular abnormalities on MRI, and underwent combined hip arthroscopy and PAO. Eleven patients did not have minimum 4-year follow-up and were excluded, leaving 67 patients (70 hips) who met our inclusion criteria and had a mean follow-up duration of 6.5 ± 1.6 years. We retrospectively evaluated patient-reported outcomes at final follow-up using the University of California Los Angeles (UCLA) activity score, the modified Harris Hip Score (mHHS), and the WOMAC pain subscore. Conversion to THA or persistent symptoms were considered clinical endpoints. Repeat surgical procedures were drawn from a prospectively maintained database, and major complications were graded according to the validated Clavien-Dindo classification (Grade III or IV). Student t-tests, chi-square tests, and Fisher exact tests identified the association of patient factors, radiographic measures, and surgical details with clinical endpoints. For patients who underwent bilateral procedures, only the first hip was included in our analyses.ResultsAt final follow-up, the mean mHHS for all patients improved from a mean ± SD of 55 ± 19 points to 85 ± 17 points (p < 0.001), the UCLA activity score improved from 6.5 ± 2.7 points to 7.5 ± 2.2 points (p = 0.01), and the WOMAC pain score improved from 9.1 ± 4.3 points to 3.2 ± 3.9 points (p < 0.001). Three percent (2 of 67) of patients underwent subsequent THA, while 21% (15 of 70) of hips were persistently symptomatic, defined as mHHS less than or equal to 70 or WOMAC pain subscore greater than or equal to 10. Univariate analyses indicated that no patient demographics, preoperative or postoperative radiographic metrics, or intraoperative findings or procedures were associated with subsequent THA or symptomatic hips. Worse baseline mHHS and WOMAC pain scores were associated with subsequent THA or symptomatic hips. Seven percent (5 of 67) of patients underwent repeat hip preservation surgery for recurrent symptoms, and 4% (3 of 67) of patients had major complications (Clavien-Dindo Grade III or IV).ConclusionThis study demonstrated that concurrent hip arthroscopy and PAO to treat symptomatic acetabular dysplasia (with intraarticular abnormalities) has good clinical outcomes at mid-term follow-up in many patients; however, persistent symptoms or conversion to THA affected almost a quarter of the sample. We noted an acceptable complication profile. Further study is needed to directly compare this approach to more traditional techniques that do not involve arthroscopy. We do not use isolated hip arthroscopy to treat symptomatic acetabular dysplasia.Level of EvidenceLevel IV, therapeutic study.  相似文献   

4.
《The Journal of arthroplasty》2020,35(8):2131-2135
BackgroundOsteogenesis imperfecta (OI) comprises a spectrum of disorders that result in bone fragility. This presents unique challenges when performing total joint arthroplasty in patients with OI. The purpose of this study is to determine the survivorship and clinical outcomes of total hip arthroplasty (THA) in patients with OI.MethodsWe retrospectively reviewed our institution’s total joint registry from 1969 to 2018 for all primary THAs in patients with a history of OI. There were 11 patients (13 hips) with a mean follow-up of 13 years (range 6-20). Survivorship free of component revision was determined using Kaplan-Meier analysis. Patient-reported clinical outcomes were assessed using Harris Hip Scores.ResultsAt final follow-up, the status of the implant was known in all 13 hips. One patient (1 hip) was deceased. Four hips (31%) underwent revision surgery at a mean of 9 years (range 5-17). Survivorship free of component revision was 52% at 20 years. Mean Harris Hip Scores at final follow-up were fair (75, 47-97), but significantly improved compared to available preoperative scores (P = .0015). No intraoperative complications occurred during the 13 primary THAs.ConclusionTHA in patients with OI is associated with high revision rates and low survivorship at long-term follow-up. Although this is a very challenging patient population, THA provided these patients with improved functional outcomes. To the authors’ knowledge, this is the largest series of primary THA in patients with OI reported in the literature and therefore provides surgeons with important data regarding the expected outcomes following THA in this unique patient population.Level of EvidenceLevel IV.  相似文献   

5.
《The Journal of arthroplasty》2022,37(10):2053-2062
BackgroundDifferent bearings have been used in total hip arthroplasty (THA), but the long-term performance is still controversial. The purpose of this study was to investigate whether there are differences when comparing THAs with 5 different bearings at a long-term follow-up of more than 10 years.MethodsFrom January 2010 to May 2012, 101 THA patients (134 hips) were divided into metal-on-metal group (MoM, 31 hips), metal-on-polyethylene group (MoP, 23 hips), ceramic-on-metal group (CoM, 21 hips), ceramic-on-ceramic group (CoC, 33 hips), and ceramic-on-polyethylene group (CoP, 26 hips). The mean follow-up period was 10.3 years. The Harris hip score (HSS), Western Ontario and McMaster Universities Osteoarthritis Index scores (WOMAC), range of motion (ROM), blood cell count, and liver-kidney function were measured. Serum and urine metal ion levels were measured using high-resolution inductively coupled plasma-mass spectrometry (ICP-MS) and a blood lymphocytes analysis was counted by flow cytometry.ResultsNo difference was observed in the HSS, WOMAC, ROM, blood cell count, or liver-kidney function among any of the 5 groups. Metal ion levels were significantly elevated in metal-containing bearings. Flow cytometry showed that no differences were found. Revision was performed due to pseudotumor in 3 patients. The implant survival rate was 96.7% and 93.3% for the MoM and CoC groups, which was significantly lower compared with other groups.ConclusionsMetal ion levels were elevated significantly in metal-containing bearings, especially in MoM THA patients. The implant survival rate was significantly lower in CoC and MoM THAs, which was mainly due to pseudotumor formation.Level of EvidenceTherapeutic Level II.  相似文献   

6.
BackgroundThe number of young patients with hematological disease requiring total hip arthroplasty (THA) is expected to increase. We aimed to investigate the long-term THA outcomes in patients with osteonecrosis of the femoral head (ONFH) following allogeneic bone marrow transplantation (BMT) for hematological disease.MethodsAll patients who underwent THA for osteonecrosis after BMT from 1997 to 2012 were identified at 2 institutions. Using propensity scores, 75 THAs in 45 patients were matched for age, gender, body mass index, American Society of Anesthesiologists score, and year of surgery with 75 THAs in 58 patients with idiopathic ONFH without a history of hematological disease (1:1 ratio). The mean age at surgery was 36.7 years and 52% were men. Clinical and radiographic evaluations were performed and clinical scores were obtained at last follow-up. Kaplan-Meier analyses were used to compare survivorship.ResultsAt a mean follow-up of 10.6 ± 3.5 years, clinical, radiographic, and survivorship outcomes, and the Harris hip scores were similar between both groups. The 13-year survivorship for all-cause revision was 93.4% for the BMT group and 95% for the control group (P = .928). No significant differences were observed between groups in the rates of reoperation (4% vs 5.3%, P = 1.000), 90-day readmission (all 5.3%), or overall mortality (4.4% vs 1.7%, P = .681). No hips had periprosthetic joint infection or septic loosening in either group. Osteolysis occurred in none of the BMT patients and in 2 hips (2.7%) of the control patients (P = .497).ConclusionThis large cohort multicenter survey at 11-year follow-up shows that contemporary cementless THA in young hematological disease patients after allogeneic BMT is not associated with a higher risk for surgical complications, revision, reoperation, readmission, and mortality compared to a matched cohort of idiopathic ONFH.  相似文献   

7.
The goal of this study was to evaluate the long-term survivorship of primary cementless total hip arthroplasty (THA) using Harris-Galante porous I acetabular and Harris-Galante porous femoral components. From July 1985 to December 1991, we performed primary cementless THA on 76 hips (70 patients). Twenty-nine patients (31 hips) died due to causes unrelated to the THA, and 6 patients (7 hips) were lost to follow-up. Of 76 hips (70 patients) studied, 38 hips (35 patients) were available for follow-up at a mean 22.5 years (range, 19-25 years) postoperatively. Mean patient age at index procedure was 51.2 years (range, 42-65 years). Average Harris Hip Score was 40.5 points preoperatively and 85.8 points at final follow-up. No patient had an early or late postoperative deep infection. Radiographically, the acetabular component fixation was stable in all 38 hips. The femoral component was bone-ingrown in 26 hips, stable-fibrous in 10, and unstable in 2. One unstable hip required revision of the femoral component. Dissociation of the polyethylene liner occurred in 3 hips without fractures of the metal locking tines and required revision of the polyethylene liner and the articular head. A total of 4 hips had documented revision, and 1 femoral component failed radiographically. The survival rate with the endpoint defined as revision surgery and radiographic loosening was 86.8% at 22.5 years of follow-up. Mean polyethylene wear was 0.085 mm/year (range, 0.031-0.15 mm). This study found that the Harris-Galante porous I acetabular and Harris-Galante porous femoral components produce excellent long-term results.  相似文献   

8.
To analyze long-term survivorship of cementless total hip arthroplasties (THAs) with the third-generation alumina ceramic-on-ceramic bearing, 100 consecutive THAs between 1996 and 1998 were reviewed. One cup and 2 stems were revised due to aseptic loosening. Another cup showed chipping of the acetabular liner at 8 years and required cup revision. The remaining hips showed stable bone ingrowth fixation with no osteolysis at the final follow-up. The 14-year survivorship as the end point of revision was 97.9% for the cup, 97.8% for the stem, and 95.7% for the overall implants, respectively. We conclude that cementless THA with the third-generation ceramic-on-ceramic hip bearing provided an excellent survivorship and eliminated periprosthetic osteolysis for 11 to 14 years.  相似文献   

9.
BackgroundCeramic on Ceramic bearings in Total Hip Arthroplasty (THA) afford a low friction coefficient, low wear rates and extreme hardness. Significant complications include hip squeak, ceramic fracture and poor polyethylene performance in revision procedures due to imbedding of abrasive microscopic ceramic fragments. We report on the results of this bearing at a minimum of 10 years.MethodsA single-centre retrospective review of 449 THAs was performed. Primary outcome measures included aseptic revision and all-cause revision rates at a minimum of 10 years post operatively. Evaluation of functionality was performed with WOMAC and SF-36 scores which were performed pre-operatively and at intervals of 6 months, one year, 2 years, 5 years and 10 years post operatively.ResultsThere was a 6.2% (n = 28) all-cause and 5.3% (n = 24) aseptic revision rate for ceramic on ceramic total hip arthroplasty at minimum of 10 years with a mean time to revision 4.8 years (range 2 months–11.6 years). Notably, there were 2 revisions for ceramic head fracture, one for ceramic liner fracture, 3 for aseptic loosening and 3 revisions for squeaking. Pain of unknown origin was the most common reason for revision. There was an improvement in postoperative WOMAC scores from a mean of 59.8 (range 15–95) pre-operatively to a mean of 15.6 (range 0–78) at 10 years.ConclusionThis study showed good functional outcomes but high revision rates for CoC THA at a minimum of 10 years. Our rates of ceramic fracture were consistent with other studies.  相似文献   

10.
This study aimed to report the outcome of total hip arthroplasty (THA) with a modular femoral component in patients younger than fifty years with osteonecrosis of femoral head. Sixty-four osteonecrotic hips in fifty-five patients were available for clinical and radiographic analyses at minimum follow-up of fifteen-years. The mean Harris hip score improved from 36 points preoperatively to 92.7 points at final follow-up. Sixty-two (95.3%) hips demonstrated stable bone ingrowth. No hips showed loosening or required revision for aseptic loosening. Survivorship with an end point of stem revision for any reason was 93.8% and for aseptic loosening was 100% at 16.8 years. We believe that cementless THA with a modular stem is a promising procedure for young and active patients with osteonecrosis of the femoral head.  相似文献   

11.
《The Journal of arthroplasty》2021,36(9):3221-3225
BackgroundS-ROM hip is a well-established and versatile prosthesis that offers extensive metaphyseal and diaphyseal geometries providing solutions for a variety of surgical scenarios. The aim of this study is to report on long-term survivorship and radiographic outcomes of complex primary total hip arthroplasty (THA) using a modular cementless stem (S-ROM).MethodsRetrospective consecutive study was conducted of 167 patients (167 hips): 97 males and 70 females with average age at the time of surgery of 55 years (range 22-76). All patients underwent complex THA by the senior author from 1987 to 1999. Patients were identified using a prospective database. Demographic, clinical, and surgical data were collected from health records. All patients received a cementless acetabular component with a standard polyethylene liner. The primary outcome measure was survivorship beyond 15 years using stem revision for any cause as an end point. Secondary outcome measure was rate of radiographic loosening using Engh classification.ResultsOnly 3 patients required stem revision for aseptic loosening and 1 for periprosthetic fracture. Isolated acetabular revision was undertaken in 23 of 167 patients (13.8%) due to polythene wear, osteolysis, and aseptic loosening. Proximal femoral stress shielding (zone 1, 7) was noted in 34 of 167 hips (20.4%). Stable bony ingrowth was noted in 144 hips (86.2%) and the remaining 23 hips had stable fibrous ingrowth (13.8%). Using stem “any-cause revision” as an endpoint, the mean stem survivorship was 31.5 years (95% confidence interval 31.007-31.985) with 30-year estimated survivorship of 97.6%.ConclusionIn a single designer surgeon series, S-ROM stem has stood the test of time with long-term, 30-year survivorship of 97.6% and continues to play an important role in modern hip surgery providing longevity and versatility. However, further comparative long-term studies from independent centers are needed for a definitive conclusion.Level of EvidenceIV.  相似文献   

12.
《The Journal of arthroplasty》2020,35(8):2161-2166
BackgroundThis study reports the long-term outcomes of a metaphyseal fit-and-fill cementless femoral component in total hip arthroplasty (THA) with a follow-up of 15-19 years.MethodsWe conducted a retrospective review of 376 consecutive THAs (345 patients), using a triple tapered stem performed between 2000 and 2003 with a view to assessing survivorship and radiological and functional outcomes. Images were assessed for initial alignment, terminal osteolysis, or subsidence, while clinical outcomes were assessed using the St Michael’s Hip Score.ResultsForty-five (11.9%) hips were lost to follow-up, 20 (5.31%) had died before our 15-year cutoff follow-up, and 4 (1.06%) had declined follow-up early on, leaving 307 hips (81.64%, 276 patients) available for both clinical and radiological follow-up at a minimum of 15 years (range 15-19). The mean age at the time of operation was 49.6 years (range 19-71) and the cohort included 131 (42.67%) male and 145 (47.23%) female patients. Seven stems (2.28%) were revised: 4 due to periprosthetic fractures, 2 for periprosthetic joint infection, and 1 for adverse reaction to metal debris at the trunnion. The St Michael’s Hip Score improved from 14.2 (range 9-23) preoperatively to 22.3 (range 13 to 25) at the last documented follow-up (P = .000). Kaplan-Meier survivorship with stem revision for any reason as the end point was 97.70%. Worst-case scenario Kaplan-Meier survivorship, where all lost to follow-up are considered as failures, was 85.3%. No stem was revised for aseptic loosening.ConclusionThis triple tapered stem in THA shows excellent survivorship beyond a minimum of 15 years.  相似文献   

13.
《The Journal of arthroplasty》2021,36(10):3519-3526
BackgroundTotal hip arthroplasty (THA) performed for developmental dysplasia of the hip is a technically difficult procedure with a high complication rate, especially in the presence of completely dislocated hips. This study aimed to evaluate at least 10 years of follow-up results of cementless, ceramic-on-ceramic (CoC) THA performed with transverse subtrochanteric osteotomy in Crowe type IV hips.MethodsWe retrospectively reviewed 50 patients’ 67 hips that underwent CoC, cementless THA with transverse subtrochanteric osteotomy between 2008 and 2011. Clinical and radiological data of the hips were examined. Clinical results were evaluated using the Harris Hip Score and the Western Ontario and McMaster Universities Osteoarthritis Index.ResultsThe mean Harris Hip Score improved from 22.9 ± 9.9 preoperatively to 94.1 ± 8.1 at the final follow-up (P < 0.001). The median Western Ontario and McMaster Universities Osteoarthritis Index score improved from 72 (interquartile range: 17) preoperatively to 2 (interquartile range: 17) postoperatively (P < 0.001). The preoperative mean leg length discrepancy was improved from 4.9 ± 1 cm to 1.5 ± 1 cm in unilateral cases at the last follow-up (P < 0.001). Revision surgery was required because of nonunion in two patients, prosthetic infection in one patient, and aseptic femoral loosening in the other patient. The overall ten-year survival rate was 94% for femoral stems and 98.5% for acetabular components as per Kaplan-Meier survival analysis.ConclusionTransverse subtrochanteric shortening osteotomy combined with using cementless acetabular and femoral components with a CoC bearing surface promises successful clinical results and high prosthesis survival in the treatment of Crowe IV hips at long-term follow-up.  相似文献   

14.
BackgroundPorous tantalum augments are versatile tools in reconstructing complex acetabular defects during revision total hip arthroplasty (THA). This study examines the clinical and radiographic outcomes of porous tantalum augments placed in the type I (flying buttress) configuration at two to 17-year follow-up in the largest cohort to-date in the literature.MethodsWe retrospectively analyzed 59 consecutive revision THAs involving the use of flying buttress augments between 2003 and 2018. The mean patient age and follow-up duration were 63.9 ± 11.6 years (range, 35-87) and 8 years (range, 2-17), respectively. The Oxford hip score was used to assess clinical outcome. The modified Moore classification was used to assess acetabular augment and shell osseointegration. Kaplan-Meier survival analysis with 95% confidence interval (CI) was used to assess implant survivorship.ResultsThe mean Oxford hip score improved from 15.9 ± 6.2 preoperatively to 35.0 ± 6.5 at a mean follow-up of eight years (P < .0001). Radiographic assessment using the modified Moore classification demonstrated five signs of osseointegration in 49 hips (83.1%), four signs in six hips (10.2%), three signs in one hip (1.7%), and one sign in one hip (1.7%). Kaplan-Meier analysis demonstrated ten-year survivorship of 88.9% (95% CI 74.4-95.4) with all-cause revision as end point and 94.3% (95% CI 83.1-98.2) with revision for acetabular aseptic loosening as end point.ConclusionTreatment of superolateral acetabular defects during revision THA using porous tantalum augments placed in the type I (flying buttress) configuration provides excellent implant survivorship and favorable clinical outcomes at mid-term follow-up.Level of EvidenceTherapeutic Level IV.  相似文献   

15.
ObjectiveCLS stem is commonly used today in primary hip arthroplasty, but only a few studies have evaluated their outcome in young high demanding patients. In Indian scenario, many patients require squatting and sitting cross-legged as part of their daily activities placing excessive load on the joint. We evaluated (I) Mid-long term functional and radiological results (II) Influence of age, gender, diagnosis, stem alignment, Canal fill index (CFI) on the outcome (III) Kaplan-Meier survivorship using revision for any reason or for aseptic loosening as an endpoint.MethodsRetrospective evaluation of 64 THA in 54 patients operated between July 2000 to July 2011 using CLS stem was done. Mean follow-up was 10.3 years (5–14.9 years) with 5 patients lost to follow-up and 4 patients died. Mean age at surgery was 46.8 years (18–78 years).ResultsMean Harris hip score was 89.4 (72–100). Thigh pain was present in 4 hips which were not associated with the sizing of the stem (p = .489). Stable fixation by bony ingrowth was seen in 53 hips (96.4%) and by fibrous ingrowth in 2 cases (3.6%) with no case of loosening seen. Stress shielding was seen as Grade II in 17 hips (30.9%), Grade III in 3 hips (5.4%). Pedestal formation was seen in 9 hips (16.4%) which were statistically associated with varus alignment and CFI < 80. No stem revision was performed with stem survivorship of 100%.ConclusionThe mid-term survival rates and good clinical-radiological outcomes of CLS stem in high demanding Indian population were excellent.  相似文献   

16.
《The Journal of arthroplasty》2020,35(12):3638-3643
BackgroundControversy exists whether previous pelvic osteotomies have negative effects on total hip arthroplasty (THA). This study evaluates the implant survival and patient-reported outcomes of THA after previous Chiari pelvic osteotomy (CPO).MethodsData on 301 THAs after CPO were collected through clinical and radiological follow-up examinations and telephone interviews. The Kaplan-Meier survivorship analysis depicts implant survival.ResultsOf this consecutive series of 1536 CPOs, follow-up was completed in 405 patients with 504 CPOs after a mean time of 36 years (±8; range, 22-54 years). At follow-up, 301 hips (60%) had already undergone THA. The overall survival of THA with revision as an end point after 10, 20, and 25 years was 93%, 76%, and 68%, respectively. The revision rate was 12%. The average period between THA and revision surgery was 9.6 years (±6.1; 4 months-25.4 years). The patient’s age at revision was 57.9 years (±10; 33.2-78.5 years). Aseptic loosening was the most common of the known reasons for revision surgery.ConclusionThis retrospective study supports the hypothesis that prior CPO does not compromise the prerequisites for successful THA at a later stage. Survival rates of the implanted prosthesis are comparable to primary implanted hips, as overall survival was 93% after 10 years.  相似文献   

17.
《The Journal of arthroplasty》2020,35(4):1042-1047
BackgroundThere is variable evidence regarding survivorship beyond 20 years of total hip arthroplasties in young patients. We report the long-term results of the Exeter cemented hip system in patients ≤50 years at minimum of 20 years.MethodsClinical and radiological outcomes of 130 consecutive total hip arthroplasties in 107 patients aged 50 years or younger at primary operation were reviewed; 77% had a diagnosis other than osteoarthritis. All patients were followed at 5-year intervals, no patients were lost to follow-up, and the status of every implant is known.ResultsMean age at surgery was 41.8 (17-50) years. Mean follow-up was 22.0 (20.0-26.1) years. There were 79 hips surviving, 14 hips (11 patients) deceased, and 37 hips revised. Reasons for revision: 29 hips for aseptic cup loosening (26 stems revised using cement-in-cement, three left in-situ); three stems for femoral osteolysis, two related to acetabular polyethylene wear (14.1 and 17.0 years), one with Gaucher’s disease (21.1 years); one broken stem (12.9 years); one cup for instability (4.3 years–stem revised using cement-in-cement); and two hips with infection (8.5 and 23.8 years). There were no cases of aseptic loosening of the Exeter stem. There were no radiologically loose stems although eight patients had radiological evidence of loosening of the cemented cup. Survivorship at 22 years was 74.9% for revision for all causes and 96.3% for revision of the stem for aseptic loosening or lysis.ConclusionThe Exeter cemented stem has excellent survivorship at minimum 20 years in young patients. Acetabular component survivorship was less favorable, but the advent of highly cross-linked polyethylene may improve this in the long term.  相似文献   

18.
BackgroundOsteopetrosis is an inherited bone disease associated with high risk of osteoarthritis and fracture non-union, which can lead to total hip arthroplasty (THA). Bone quality and morphology are altered in these patients, and there are limited data on results of THA in these patients. The goals of this study were to describe implant survivorship, clinical outcomes, radiographic results, and complications in patients with osteopetrosis undergoing primary THA.MethodsWe identified 7 patients (9 hips) with osteopetrosis who underwent primary THA between 1970 and 2017 utilizing our total joint registry. The mean age at index THA was 48 years and included two males and five females. The mean follow-up was 8 years.ResultsThe 10-year survivorship free from any revision or implant removal was 89%, with 1 revision and 1 resection arthroplasty secondary to periprosthetic femoral fractures. The 10-year survivorship free from any reoperation was 42%, with 4 additional reoperations (2 ORIFs for periprosthetic femoral fractures, 1 sciatic nerve palsy lysis of adhesions, 1 hematoma evacuation). Harris hip scores significantly increased at 5 years (P = .04). Five hips had an intraoperative acetabular fracture, and 1 had an intraoperative femur fracture. All postoperative femoral fractures occurred in patients with intramedullary diameter less than 5 mm at a level 10 cm distal to the lesser trochanter.ConclusionPrimary THA in patients with osteopetrosis is associated with good 10-year implant survivorship (89%), but a very high reoperation (58%) and periprosthetic femoral fracture rate (44%). Femoral fractures appear associated with smaller intramedullary diameters.  相似文献   

19.
《Injury》2021,52(6):1467-1472
IntroductionTotal hip arthroplasty (THA) after femoral neck fracture (FNF) is associated with an increased risk of dislocation. The goals of our study were (1) to determine dislocation and revision rates when dual-mobility cups (DMCs) are used in these patients, (2) to analyze clinical and radiographic outcomes, survivorship, complications and mortality rate, and (3) to compare results between cemented and cementless cups.Patients and methodsWe retrospectively reviewed patients with FNF treated using DMC-THA between 2011 and 2018. A minimum 2-year follow-up was required for clinical and radiographic assessment. The clinical outcome was assessed using the Harris Hip Score (HHS) and Merlé D´Aubigné-Postel score (MDP). Radiolucent lines, osteolysis and cup loosening were analyzed.ResultsWe included 105 patients (105 hips) with a mean age of 75.5 years. There were no dislocations. One patient (1.0%) underwent cup revision at 39 months for aseptic cup loosening. The mean HHS and MDP were 80.5 and 14.2 respectively at a mean follow-up of 4.1 years. A higher MDP was found in patients with cementless rather than cemented cups (15.0 vs. 13.1; p = 0.006). Four patients had radiolucent lines > 1 mm, around cemented cups. At 6.8 years, estimated cup survival was 98.2% for revision for aseptic loosening and 97.3% for revision for any reason. The mortality rates were 6.7% at 1 year and 23.8% at last follow-up.ConclusionOur findings suggest that using DMC in THA for FNF may prevent dislocation with a low revision rate. Cementless cups had a higher MDP than cemented cups.  相似文献   

20.
We present a retrospective evaluation of 1369 hip arthroplasties performed using the Bicon-Plus cups and SL-Plus stems, differing only in the bearing combination. Four bearing combination groups were used: metal-on-polyethylene (MoP) group with 587 hips, ceramic-on-polyethylene (CoP) group with 161 hips, metal-on-metal (MoM) group with 322 hips and ceramic-on-ceramic (CoC) group with 299 hips. The mean follow-up was 11.5 years (4.1 to 15.0). Radiological evaluation was performed on implants failed due to aseptic loosening. The survival for prosthesis with revision for any reason at ten years was 96.1% (95% confidence interval (CI) 94.3 to 97.9) for MoP, 98.1% (CI 95.9 to 100) for CoP, 90.2% (CI 86.8 to 93.6) for MoM, and 95.6% (CI 93.0 to 98.2) for CoC. Survival for aseptic loosening was also determined.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号