首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Purpose

We evaluated whether the maximum standardized uptake values (SUVmax) of primary tumor from the initial staging by 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) of patients with breast cancer could identify patients at risk for early recurrence within 2 years, particularly in comparison to the American Joint Committee on Cancer (AJCC) stage.

Methods

We reviewed the staging 18F-FDG PET/CT images of patients with primary breast cancer and their medical records. The SUVmax of the primary tumor was measured. The presence or absence of FDG uptake in the axillary lymph node (ALN) was also assessed. The patient’s pathologic primary tumor stage (pT), pathologic regional lymph node stage (pN), stage grouping, age, estrogen receptor (ER) and progesterone receptor (PR) status, and neoadjuvant chemotherapy history were evaluated with the FDG uptake parameters for recurrence within 2 years following the end of first-line therapy.

Results

Recurrence within 2 years was present in 9.1 % (n = 40) out of the 441 patients assessed. The FDG uptake in ALN, pT, pN, stage grouping and neoadjuvant chemotherapy history were prognostic for early recurrence, while primary tumor SUVmax, age, and ER or PR status were not significant on logistic regression. On multivariate analysis, only the stage grouping (odds ratio 2.79; 95 % CI 1.73, 4.48; p < 0.0001) and neoadjuvant chemotherapy history (odds ratio 2.70; 95 % CI 1.22, 5.98; p = 0.0141) could identify patients at increased risk for recurrence within 2 years.

Conclusions

Primary tumor FDG uptake measured by SUVmax, and visual assessment of FDG uptake in the ALN in the initial staging PET/CT of patients with breast cancer may not have additional prognostic value compared with the AJCC stage grouping for early recurrence.  相似文献   

2.

Objective

To evaluate the efficacy of newly designed covered and non-covered coated colorectal stents for colonic decompression.

Materials and Methods

Twenty-six patients, (15 palliative cases and 11 preoperative) underwent treatment for the relief of colorectal obstruction using metallic stents positioned under fluoroscopic guidance. In 24 of the 26, primary colorectal carcinoma was diagnosed, and in the remaining two, recurrent colorectal carcinoma. Twenty-one patients were randomly selected to receive either a type A or type B stent; for the remaining five, type C was used. Type A, an uncovered nitinol wire stent, was lightly coated to ensure structural integrity. Type B (flare type) and C (shoulder type) stents were polyurethane covered and their diameter was 24 and 26mm, respectively. The rates of technical success, clinical success, and complications were analyzed using the chi-square test, and to analyse the mean period of patency, the Kaplan-Meier method was used.

Results

Thirty of 31 attempted placements in 26 patients were successful, with a technical success rate of 96.8% (30/31) and a clinical success rate of 80.0% (24/30). After clinically successful stent placement, bowel decompression occurred within 1-4 (mean, 1.58 ± 0.9) days. Five of six clinical failures involved stent migration and one stent did not expand after successful placement. In the preoperative group, 11 stents, one of which migrated, were placed in ten patients, in all of whom bowel preparation was successful. In the palliative group, 19 stents were placed in 15 patients. The mean period of patency was 96.25 ± 105.12 days: 146.25 ± 112.93 for type-A, 78.82 ± 112.26 for type-B, and 94.25 ± 84.21 for type-C. Complications associated with this procedure were migration (n=6, 20%), pain (n=4, 13.3%), minor bleeding (n=5, 16.7%), incomplete expansion (n=1, 3.3%), and tumor ingrowth (n=1, 3.3%). The migration rate was significantly higher in the type-B group than in other groups (p=0.038).

Conclusion

Newly designed covered and non-covered metallic stents of a larger diameter are effective for the treatment of colorectal obstruction. The migration rate of covered stents with flaring is higher than that of other types. For evaluation of the ideal stent configuration for the relief of colorectal obstruction, a clinical study involving a larger patient group is warranted.  相似文献   

3.

Objective

This study was conducted to assess the feasibility of performing 100-kVp electrocardiogram (ECG)-gated coronary CT angiography, as compared to 120-kVp ECG-gated coronary CT angiography.

Materials and Methods

We retrospectively evaluated one hundred eighty five gender- and body mass index-matched 16-slice coronary CT sets of data, which were obtained using either 100 kVp and 620 effective mAs or 120 kVp and 500 effective mAs. The density measurements (image noise, vessel density, signal-to-noise ratio [SNR] and contrast-to-noise ratio [CNR]) and the estimated radiation dose were calculated. As a preference test, two image readers were independently asked to choose one image from each pair of images. The results of both protocols were compared using the paired t-test or the Wilcoxon signed rank test.

Results

The 100-kVp images showed significantly more noise and a significantly higher vessel density than did the 120-kVp images. There were no significant differences in the SNR and CNR. The estimated reduction of the radiation dose for the 100-kVp protocol was 24%; 7.8 ± 0.4 mSV for 100-kVp and 10.1 ± 1.0 mSV for 120-kVp (p < 0.001). The readers preferred the 100-kVp images for reading (reader 1, p = 0.01; reader 2, p = 0.06), with their preferences being stronger when the subject''s body mass index was less than 25.

Conclusion

Reducing the tube kilovoltage from 120 to 100 kVp allows a significant reduction of the radiation dose without a significant change in the SNR and the CNR.  相似文献   

4.

Objective

Neointimal hyperplasia is a major complication of endovascular stent placement with consequent in-stent restenosis or occlusion. Improvements in the biocompatibility of stent designs could reduce stent-associated thrombosis and in-stent restenosis. We hypothesised that the use of a diamond-like carbon (DLC)-coated nitinol stent or a polyethylene glycol (PEG)-DLC-coated nitinol stent could reduce the formation of neointimal hyperplasia, thereby improving stent patency with improved biocompatibility.

Methods

A total of 24 stents were implanted, under general anaesthesia, into the iliac arteries of six dogs (four stents in each dog) using the carotid artery approach. The experimental study dogs were divided into three groups: the uncoated nitinol stent group (n = 8), the DLC-nitinol stent group (n = 8) and the PEG-DLC-nitinol stent group (n = 8).

Results

The mean percentage of neointimal hyperplasia was significantly less in the DLC-nitinol stent group (26.7±7.6%) than in the nitinol stent group (40.0±20.3%) (p = 0.021). However, the mean percentage of neointimal hyperplasia was significantly greater in the PEG-DLC-nitinol stent group (58.7±24.7%) than in the nitinol stent group (40.0±20.3%) (p = 0.01).

Conclusion

Our findings indicate that DLC-coated nitinol stents might induce less neointimal hyperplasia than conventional nitinol stents following implantation in a canine iliac artery model; however, the DLC-coated nitinol stent surface when reformed with PEG induces more neointimal hyperplasia than either a conventional or DLC-coated nitinol stent.  相似文献   

5.

Objective

To determine the usefulness of perfusion MR imaging in assessing the histologic grade of cerebral gliomas.

Materials and Methods

In order to determine relative cerebral blood volume (rCBV), 22 patients with pathologically proven gliomas (9 glioblastomas, 9 anaplastic gliomas and 4 low-grade gliomas) underwent dynamic contrast-enhanced T2*-weighted and conventional T1- and T2-weighted imaging. rCBV maps were obtained by fitting a gamma-variate function to the contrast material concentration versus time curve. rCBV ratios between tumor and normal white matter (maximum rCBV of tumor / rCBV of contralateral white matter) were calculated and compared between glioblastomas, anaplastic gliomas and low-grade gliomas.

Results

Mean rCBV ratios were 4.90°±1.01 for glioblastomas, 3.97°±0.56 for anaplastic gliomas and 1.75°±1.51 for low-grade gliomas, and were thus significantly different; p < .05 between glioblastomas and anaplastic gliomas, p < .05 between anaplastic gliomas and low-grade gliomas, p < .01 between glioblastomas and low-grade gliomas. The rCBV ratio cutoff value which permitted discrimination between high-grade (glioblastomas and anaplastic gliomas) and low-grade gliomas was 2.60, and the sensitivity and specificity of this value were 100% and 75%, respectively.

Conclusion

Perfusion MR imaging is a useful and reliable technique for estimating the histologic grade of gliomas.  相似文献   

6.

Objective

The quality and radiation dose of different tube voltage sets for chest digital radiography (DR) were compared in a series of pediatric age groups.

Materials and Methods

Forty-five hundred children aged 0-14 years (yr) were randomly divided into four groups according to the tube voltage protocols for chest DR: lower kilovoltage potential (kVp) (A), intermediate kVp (B), and higher kVp (C) groups, and the fixed high kVp group (controls). The results were analyzed among five different age groups (0-1 yr, 1-3 yr, 3-7 yr, 7-11 yr and 11-14 yr). The dose area product (DAP) and visual grading analysis score (VGAS) were determined and compared by using one-way analysis of variance.

Results

The mean DAP of protocol C was significantly lower as compared with protocols A, B and controls (p < 0.05). DAP was higher in protocol A than the controls (p <0.001), but it was not statistically significantly different between B and the controls (p = 0.976). Mean VGAS was lower in the controls than all three protocols (p < 0.001 for all). Mean VGAS did not differ between protocols A and B (p = 0.334), but was lower in protocol C than A (p = 0.008) and B (p = 0.049).

Conclusion

Protocol C (higher kVp) may help optimize the trade-off between radiation dose and image quality, and it may be acceptable for use in a pediatric age group from these results.  相似文献   

7.

Objective

To assess the feasibility of visualizing hand and foot tendon anatomy and disorders by Gemstone Spectral Imaging (GSI) high-definition CT (HDCT).

Materials and Methods

Thirty-five patients who suffered from hand or foot pain were scanned with GSI mode HDCT and MRI. Spectrum analysis was used to select the monochromatic images that provide the optimal contrast-to-noise ratio (CNR) for tendons. The image quality at the best selected monochromatic level and the conventional polychromatic images were compared. Tendon anatomy and disease were also analyzed at GSI and MRI.

Results

The monochromatic images at about 65 keV (mean 65.09 ± 2.98) provided the optimal CNR for hand and foot tendons. The image quality at the optimal selected monochromatic level was superior to conventional polychromatic images (p = 0.005, p < 0.05). GSI was useful in visualizing hand and foot tendon anatomy and disorders. There were no statistical differences between GSI and MRI with regard to tendon thickening (χ2 = 0, p > 0.05), compression (χ2 = 0.5, p > 0.05), absence (χ2 = 0, p > 0.05) and rupture (χ2 = 0, p > 0.05). GSI was significantly less sensitive than MRI in displaying tendon adhesion (χ2 = 4.17, p < 0.05), degeneration (χ2 = 4.17, p < 0.05), and tendinous sheath disease (χ2 = 10.08, p < 0.05).

Conclusion

GSI with monochromatic images at 65 keV displays clearly the most hand and foot tendon anatomy and disorders with image quality improved, as compared with conventional polychromatic images. It may be used solely or combined with MRI in clinical work, depending on individual patient disease condition.  相似文献   

8.

Objective

To assess differences in skin temperature between the operated and control side of the face after mandibular third molar surgery using thermography.

Methods

127 patients had 1 mandibular third molar removed. Before the surgery, standardized thermograms were taken of both sides of the patient''s face using a Flir ThermaCam™ E320 (Precisions Teknik AB, Halmstad, Sweden). The imaging procedure was repeated 2 days and 7 days after surgery. A region of interest including the third molar region was marked on each image. The mean temperature within each region of interest was calculated. The difference between sides and over time were assessed using paired t-tests.

Results

No significant difference was found between the operated side and the control side either before or 7 days after surgery (p > 0.3). The temperature of the operated side (mean: 32.39 °C, range: 28.9–35.3 °C) was higher than that of the control side (mean: 32.06 °C, range: 28.5–35.0 °C) 2 days after surgery [0.33 °C, 95% confidence interval (CI): 0.22–0.44 °C, p < 0.001]. No significant difference was found between the pre-operative and the 7-day post-operative temperature (p > 0.1). After 2 days, the operated side was not significantly different from the temperature pre-operatively (p = 0.12), whereas the control side had a lower temperature (0.57 °C, 95% CI: 0.29–0.86 °C, p < 0.001).

Conclusions

Thermography seems useful for quantitative assessment of inflammation between the intervention side and the control side after surgical removal of mandibular third molars. However, thermography cannot be used to assess absolute temperature changes due to normal variations in skin temperature over time.  相似文献   

9.

Objective

To test the effects of heart rate, body mass index (BMI) and noise level on interscan and interobserver variability of coronary artery calcium (CAC) scoring on a prospective electrocardiogram (ECG)-triggered 64-slice CT.

Materials and Methods

One hundred and ten patients (76 patients with CAC) were scanned twice on prospective ECG-triggered scans. The scan parameters included 120 kV, 82 mAs, a 2.5 mm thickness, and an acquisition center at 45% of the RR interval. The interscan and interobserver variability on the CAC scores (Agatston, volume, and mass) was calculated. The factors affecting the variability were determined by plotting it against heart rate, BMI, and noise level (defined as the standard deviation: SD).

Results

The estimated effective dose was 1.5 ± 0.2 mSv. The mean heart rate was 63 ± 12 bpm (range, 44-101 bpm). The patient BMIs were 24.5 ± 4.5 kg/m2 (range, 15.5-42.3 kg/m2). The mean and median interscan variabilities were 11% and 6%, respectively by volume, and 11% and 6%, respectively, by mass. Moreover, the mean and median of the algorithms were lower than the Agatston algorithm (16% and 9%, respectively). The mean and median interobserver variability was 10% and 4%, respectively (average of algorithms). The mean noise levels were 15 ± 4 Hounsfield unit (HU) (range, 8-25 HU). The interscan and interobserver variability was not correlated with heart rate, BMI, or noise level.

Conclusion

The interscan and interobserver variability of CAC on a prospective ECG-triggered 64-slice CT with high image quality and 45% of RR acquisition is not significantly affected by heart rate, BMI, or noise level. The volume or mass algorithms show reduced interscan variability compared to the Agatston scoring (p < 0.05).  相似文献   

10.

Objective

Arsenic trioxide (As2O3) can be used as a possible pharmaceutical alternative that augments radiofrequency (RF) ablation by reducing tumor blood flow. The aim of this study was to assess the effect of intraarterial and intravenous administration of As2O3 on RF-induced ablation in an experimentally induced liver tumor.

Materials and Methods

VX2 carcinoma was grown in the livers of 30 rabbits. As2O3 (1 mg/kg) was administered through the hepatic artery (n = 10, group A) or ear vein (n = 10, group B), 30 minutes before RF ablation (125 mA ± 35; 90 ± 5℃). As a control group, 10 rabbits were treated with RF ablation alone (group C). RF was intentionally applied to the peripheral margin of the tumor so that ablation can cover the tumor and adjacent hepatic parenchyma. Ablation areas of the tumor and adjacent parenchymal changes among three groups were compared by the Kruskal-Wallis and Mann-Whitney U test.

Results

The overall ablation areas were 156 ± 28.9 mm2 (group A), 119 ± 31.7 (group B), and 92 ± 17.4 (group C, p < 0.04). The ablation area of the tumor was significantly larger in group A (73 ± 19.7 mm2) than both group B (50 ± 19.4, p = 0.02) and group C (28 ± 2.2, p < 0.01). The ratios of the tumoral ablation area to the overall ablation area were larger in group A (47 ± 10.5%) than that of the other groups (42 ± 7.3% in group B and 32 ± 5.6% in group C) (p < 0.03).

Conclusion

Radiofrequency-induced ablation area can be increased with intraarterial or intravenous administration of As2O3. The intraarterial administration of As2O3 seems to be helpful for the selective ablation of the tumor.  相似文献   

11.

Objective

We investigated low dose digital tomosynthesis (DT) for the evaluation of the paranasal sinus (PNS), and compared its diagnostic accuracy with a PNS radiography series (XR).

Materials and Methods

We enrolled 43 patients for whom XR, PNS DT, and OMU CT were performed. We measured effective doses (EDs) of XR, DT, and OMU CT using Monte Carlo simulation software. Two radiologists performed independent observation of both XR and DT. For seven PNSs, they scored anatomic conspicuity of sinuses and confidence on the presence of sinusitis using nine point scales. OMU CT was observed by the third radiologist and the findings were regarded as reference standard. We compared scores for conspicuity and sinusitis confidence between XR and DT.

Results

Mean EDs were 29 ± 6 µSv, 48 ± 10 µSv, and 980 ± 250 µSv, respectively, for XR, DT, and CT. Mean scores for conspicuity were 6.3 and 7.4, respectively, for XR and DT. Sensitivity per patient basis for sinusitis detection were 52% and 96%, respectively, for XR and DT in observer 1 (p = 0.001) and 80% and 92% for observer 2 (p = 0.25). Specificities for sinusitis exclusion were 100% for both XR and DT for observer 1 and 89% and 100% for observer 2 (p = 0.50). Accuracies for sinusitis diagnosis were 72% and 98%, respectively, for XR and DT for observer 1 (p = 0.001) and 84% and 95% for observer 2 (p = 0.125).

Conclusion

Patient radiation dose from low dose DT is comparable with that of PNS XR. Diagnostic sensitivity of DT for sinusitis was superior to PNS XR.  相似文献   

12.

Objective

To determine whether the image quality (IQ) is improved with iterative reconstruction in image space (IRIS), and whether IRIS can be used for radiation reduction in chest CT.

Materials and Methods

Standard dose chest CT (SDCT) in 50 patients and low dose chest CT (LDCT) in another 50 patients were performed, using a dual-source CT, with 120 kVp and same reference mAs (50 mAs for SDCT and 25 mAs for LDCT) employed to both tubes by modifying a dual-energy scan mode. Full-dose data were obtained by combining the data from both tubes and half-dose data were separated from a single tube. These were reconstructed by using a filtered back projection (FBP) and IRIS: full-dose FBP (F-FBP); full-dose IRIS (F-IRIS); half-dose FBP (H-FBP) and half-dose IRIS (H-IRIS). Objective noise was measured. The subjective IQ was evaluated by radiologists for the followings: noise, contrast and sharpness of mediastinum and lung.

Results

Objective noise was significantly lower in H-IRIS than in F-FBP (p < 0.01). In both SDCT and LDCT, the IQ scores were highest in F-IRIS, followed by F-FBP, H-IRIS and H-FBP, except those for sharpness of mediastinum, which tended to be higher in FBP. When comparing CT images between the same dose and different reconstruction (F-IRIS/F-FBP and H-IRIS/H-FBP) algorithms, scores tended to be higher in IRIS than in FBP, being more distinct in half-dose images. However, despite the use of IRIS, the scores were lower in H-IRIS than in F-FBP.

Conclusion

IRIS generally helps improve the IQ, being more distinct at the reduced radiation. However, reduced radiation by half results in IQ decrease even when using IRIS in chest CT.  相似文献   

13.

Objectives

The purpose of this study was to compare mandibular linear distances measured from cone beam CT (CBCT) images produced by different radiographic parameter settings (peak kilovoltage and milliampere value).

Methods

20 cadaver hemimandibles with edentulous ridges posterior to the mental foramen were embedded in clear resin blocks and scanned by a CBCT machine (CB MercuRayTM; Hitachi Medico Technology Corp., Chiba-ken, Japan). The radiographic parameters comprised four peak kilovoltage settings (60 kVp, 80 kVp, 100 kVp and 120 kVp) and two milliampere settings (10 mA and 15 mA). A 102.4 mm field of view was chosen. Each hemimandible was scanned 8 times with 8 different parameter combinations resulting in 160 CBCT data sets. On the cross-sectional images, six linear distances were measured. To assess the intraobserver variation, the 160 data sets were remeasured after 2 weeks. The measurement precision was calculated using Dahlberg''s formula. With the same peak kilovoltage, the measurements yielded by different milliampere values were compared using the paired t-test. With the same milliampere value, the measurements yielded by different peak kilovoltage were compared using analysis of variance. A significant difference was considered when p < 0.05.

Results

Measurement precision varied from 0.03 mm to 0.28 mm. No significant differences in the distances were found among the different radiographic parameter combinations.

Conclusions

Based upon the specific machine in the present study, low peak kilovoltage and milliampere value might be used for linear measurements in the posterior mandible.  相似文献   

14.

Objective

To assess the image quality and effective radiation dose of prospectively electrocardiogram (ECG)-gated high-pitch spiral acquisition mode (flash mode) of dual-source CT (DSCT) coronary angiography (CTCA) in patients with high heart rates (HRs) as compared with retrospectively ECG-gated spiral acquisition mode.

Materials and Methods

Two hundred and sixty-eight consecutive patients (132 female, mean age: 55 ± 11 years) with mean HR > 65 beats per minute (bpm) were prospectively included in this study. The patients were divided into two groups. Collection was performed in group A CTCA using flash mode setting at 20-30% of the R-R interval, and retrospectively ECG-gated spiral acquisition mode in group B. The image noise, contrast-to-noise ratio (CNR), image quality scores, effective radiation dose and influencing factors on image quality between the two groups were assessed.

Results

There were no significant differences in image quality scores and proportions of non-diagnostic coronary artery segments between two groups (image quality scores: 1.064 ± 0.306 [group A] vs. 1.084 ± 0.327 [group B], p = 0.063; proportion of non-diagnostic coronary artery segments: segment-based analysis 1.52% (group A) vs. 1.74% (group B), p = 0.345; patient-based analysis 7.5% (group A) vs. 6.7% (group B), p = 0.812). The estimated radiation dose was 1.0 ± 0.16 mSv in group A and 7.1 ± 1.05 mSv in group B (p = 0.001).

Conclusion

In conclusion, in patients with HRs > 65 bpm without cardiac arrhythmia, the prospectively high-pitch spiral-acquisition mode with image-acquired timing set at 20-30% of the R-R interval provides a similar image quality and low rate of non-diagnostic coronary segments to the retrospectively ECG-gated low-pitch spiral acquisition mode, with significant reduction of radiation exposure.  相似文献   

15.

Objective

We wanted to investigate the feasibility of using FDG-PET for evaluating the antitumor effect of intraarterial administration of a hexokinase II inhibitor, 3-bromopyruvate (3-BrPA), in a rabbit VX2 liver tumor model.

Materials and Methods

VX2 carcinoma was grown in the livers of ten rabbits. Two weeks later, liver CT was performed to confirm appropriate tumor growth for the experiment. After tumor volume-matched grouping of the rabbits, transcatheter intraarterial administration of 3-BrPA was performed (1 mM and 5 mM in five animals each, respectively). FDG-PET scan was performed the day before, immediately after and a week after 3-BrPA administration. FDG uptake was semiquantified by measuring the standardized uptake value (SUV). A week after treatment, the experimental animals were sacrificed and the necrosis rates of the tumors were calculated based on the histopathology.

Results

The SUV of the VX2 tumors before treatment (3.87 ±1.51 [mean ±SD]) was significantly higher than that of nontumorous liver parenchyma (1.72 ±0.34) (p < 0.0001, Mann-Whitney U test). The SUV was significantly decreased immediately after 3-BrPA administration (2.05 ±1.21) (p = 0.002, Wilcoxon signed rank test). On the one-week follow up PET scan, the FDG uptake remained significantly lower (SUV 1.41 ±0.73) than that before treatment (p = 0.002), although three out of ten animals showed a slightly increasing tendency for the FDG uptake. The tumor necrosis rate ranged from 50.00% to 99.90% (85.48% ±15.87). There was no significant correlation between the SUV or the SUV decrease rate and the tumor necrosis rate in that range.

Conclusion

Even though FDG-PET cannot exactly reflect the tumor necrosis rate, FDG-PET is a useful modality for the early assessment of the antitumor effect of intraarterial administration of 3-BrPA in VX2 liver tumor.  相似文献   

16.

Objective

To define the mechanism associated with abnormal septal motion (ASM) after coronary artery bypass graft surgery (CABG) using comprehensive MR imaging techniques.

Materials and Methods

Eighteen patients (mean age, 58 ± 12 years; 15 males) were studied with comprehensive MR imaging using rest/stress perfusion, rest cine, and delayed enhancement (DE)-MR techniques before and after CABG. Myocardial tagging was also performed following CABG. Septal wall motion was compared in the ASM and non-ASM groups. Preoperative and postoperative results with regard to septal wall motion in the ASM group were also compared. We then analyzed circumferential strain after CABG in both the septal and lateral walls in the ASM group.

Results

All patients had normal septal wall motion and perfusion without evidence of non-viable myocardium prior to surgery. Postoperatively, ASM at rest and/or stress state was documented in 10 patients (56%). However, all of these had normal rest/stress perfusion and DE findings at the septum. Septal wall motion after CABG in the ASM group was significantly lower than that in the non-ASM group (2.1±5.3 mm vs. 14.9±4.7 mm in the non-ASM group; p < 0.001). In the ASM group, the degree of septal wall motion showed a significant decrease after CABG (preoperative vs. postoperative = 15.8±4.5 mm vs. 2.1±5.3 mm; p = 0.007). In the ASM group after CABG, circumferential shortening of the septum was even larger than that of the lateral wall (-20.89±5.41 vs. -15.41±3.7, p < 0.05)

Conclusion

Abnormal septal motion might not be caused by ischemic insult. We suggest that ASM might occur due to an increase in anterior cardiac mobility after incision of the pericardium.  相似文献   

17.

Objective

To investigate the value of spectral CT imaging in the diagnosis and classification of liver cirrhosis during the arterial phase (AP) and portal venous phase (PVP).

Materials and Methods

Thirty-eight patients with liver cirrhosis (Child-Pugh class A/B/C: n = 10/14/14), and 43 patients with healthy livers, participated in this study. The researchers used abdominal spectral CT imaging during AP and PVP. Iodine concentration, derived from the iodine-based material-decomposition image and the iodine concentration ratio (ICratio) between AP and PVP, were obtained. Statistical analyses {two-sample t test, One-factor analysis of variance, and area under the receiver operating characteristic curve (A [z])} were performed.

Results

The mean normalized iodine concentration (NIC) (0.5 ± 0.12) during PVP in the control group was significantly higher than that in the study group (0.4 ± 0.10 on average, 0.4 ± 0.08 for Class A, 0.4 ± 0.15 for Class B, and 0.4 ± 0.06 for Class C) (All p < 0.05). Within the cirrhotic liver group, the mean NIC for Class C during the AP (0.1 ± 0.05) was significantly higher than NICs for Classes A (0.1 ± 0.06) and B (0.1 ± 0.03) (Both p < 0.05). The ICratio in the study group (0.4 ± 0.15), especially for Class C (0.5 ± 0.14), was higher than that in the control group (0.3 ± 0.15) (p < 0.05).The combination of NIC and ICratio showed high sensitivity and specificity for differentiating healthy liver from cirrhotic liver, especially in Class C cirrhotic liver.

Conclusion

Spectral CT Provides a quantitative method with which to analyze the cirrhotic liver, and shows the potential value in the classification of liver cirrhosis.  相似文献   

18.

Objective

This study was designed to evaluate in vivo MR imaging for the depiction of intraarterially injected superparamagnetic iron oxide (SPIO)-labeled mesenchymal stem cells (MSCs) in an experimental rat model of renal ischemia.

Materials and Methods

Left renal ischemia was induced in 12 male Sprague-Dawley rats by use of the catheter lodging method. In vivo MR signal intensity variations depicted on T2*-weighted sequences were evaluated in both the left and right kidneys prior to injection (n = 2), two hours (n = 4), 15 hours (n = 2), 30 hours (n = 2) and 72 hours (n = 2) after injection of SPIO-labeled MSCs in both kidneys. Signal intensity variations were correlated with the number of Prussian blue stain-positive cells as visualized in histological specimens.

Results

In an in vivo study, it was determined that there was a significant difference in signal intensity variation for both the left and right cortex (40.8 ± 4.12 and 26.4 ± 7.92, respectively) and for both the left and right medulla (23.2 ± 3.32 and 15.2 ± 3.31, respectively) until two hours after injection (p < 0.05). In addition, signal intensity variation in the left renal cortex was well correlated with the number of Prussian blue stain-positive cells per high power field (r = 0.98, p < 0.05).

Conclusion

Intraarterial injected SPIO-labeled MSCs in an experimental rat model of renal ischemia can be detected with the use of in vivo MR imaging immediately after injection.  相似文献   

19.

Objective

To evaluate the impact of radiation dose and reconstruction algorithms on radiologists'' preferences, and whether an iterative reconstruction in image space (IRIS) can be used for dose reduction in chest CT.

Materials and Methods

Standard dose chest CT (SDCT) in 50 patients and low dose chest CT (LDCT) in another 50 patients were performed, using a dual-source CT, with 120 kVp and same reference mAs (50 mAs for SDCT and 25 mAs for LDCT) employed to both tubes by modifying the dual-energy scan mode. Full-dose data were obtained by combining the data from both tubes and half-dose data were separated from one tube. These were reconstructed by using a filtered back projection (FBP) and IRIS: full-dose FBP (F-FBP); full-dose IRIS (F-IRIS); half-dose FBP (H-FBP) and half-dose IRIS (H-IRIS). Ten H-IRIS/F-IRIS, 10 H-FBP/H-IRIS, 40 F-FBP/F-IRIS and 40 F-FBP/H-IRIS pairs of each SDCT and LDCT were randomized. The preference for clinical usage was determined by two radiologists with a 5-point-scale system for the followings: noise, contrast, and sharpness of mediastinum and lung.

Results

Radiologists preferred IRIS over FBP images in the same radiation dose for the evaluation of the lungs in both SDCT (p = 0.035) and LDCT (p < 0.001). When comparing between H-IRIS and F-IRIS, decreased radiation resulted in decreased preference. Observers preferred H-IRIS over F-FBP for the lungs in both SDCT and LDCT, even with reduced radiation dose by half in IRIS image (p < 0.05).

Conclusion

Radiologists'' preference may be influenced by both radiation dose and reconstruction algorithm. According to our preliminary results, dose reduction at 50% with IRIS may be feasible for lung parenchymal evaluation.  相似文献   

20.

Objective

The aim of this study was to determine (1) the effect of various scan delays on pixel intensity measurements and (2) the diagnostic accuracy of occlusal caries detection.

Methods

72 non-cavitated extracted human permanent molar teeth with sound and carious occlusal surfaces were radiographed using the DIGORA® storage phosphor plates (SPPs) (Soredex Corporation, Helsinki, Finland). Plates were scanned immediately and 10 min, 30 min, 60 min and 120 min after exposure. Three different plates were used for each scan delay. An aluminium (Al) wedge was used to evaluate the change in mean grey values (MGVs) for scan delays. Diagnostic accuracy for occlusal caries detection was performed by scoring all the digital images. The true presence of caries was determined by stereomicroscopy. Comparison of MGVs of the Al wedge for immediate and delayed scans was made using repeated measures analysis of variance (ANOVA) and Tukey–Kramer tests. The accuracy was expressed as the area under the receiver operating characteristics curves (Az). Azs were compared using two-way ANOVA and t-tests. Kappa was used to measure inter and intraobserver agreement.

Results

The mean Azs of immediately scanned plates were higher than the Azs of plates scanned with four different delays (p < 0.05). The Az of immediately scanned images was significantly higher than the Azs of images with 60 min and 120 min scan delays (p < 0.05) but not for 10 min and 30 min delays (p > 0.05). MGVs of immediately scanned plates were significantly higher than the plates scanned with four different delays (p < 0.05). Agreement decreased with increasing scan delays.

Conclusion

Scanning of DIGORA SPPs should not be delayed beyond 30 min for accurate occlusal caries diagnosis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号