1.
ObjectivesTo investigate the bond strength between cpTi and low fusing porcelains after different treatments.Methods72 patterns were covered with a ceramic coating and invested with phosphate-bonded material (group A), another 72 were invested with magnesia material (group B) and all cast with cpTi. 31 solid castings were selected from each group. The castings of group B were ground and sandblasted, while the castings of group A were only sandblasted. Aluminum content of the metal surface was determined by EDS and castings were submitted to a 3-point bending test to determine the modulus of elasticity (E). The porcelains Duceratin Plus, Noritake Ti22 and Triceram were applied respectively and specimens were submitted to a 3-point bending test. The fracture mode and the remaining porcelain were determined by optical microscopy and SEM/EDS. Bond strength and fracture mode were calculated by two-way ANOVA.ResultsThe E of groups A and B was 98.3 GPa and 98.6 GPa respectively. The bond strength was 26 ± 3 MPa (Duceratin Plus), 28 ± 3 MPa (Noritake Ti22), 27 ± 2 MPa (Triceram) for group A and 24 ± 1 MPa, 29 ± 2 MPa, 27 ± 1 MPa for group B respectively. No significant differences were found for the same porcelain between the two groups (p < 0.05). A significant difference was found between Duceratin Plus and Noritake Ti22, for group B (p < 0.05). The mode of failure was mainly adhesive for all specimens. A significant reduction in aluminum was recorded in all subgroups.SignificanceThe special coating of patterns makes the Ti casting procedure inexpensive, without reducing the metal–ceramic bond strength.  相似文献   

2.
ObjectivesThis study investigated the effect of extreme cooling methods on the flexural strength, reliability and shear bond strength of veneer porcelain for zirconia.MethodsVita VM9 porcelain was sintered on zirconia bar specimens and cooled by one of the following methods: inside a switched-off furnace (slow), at room temperature (normal) or immediately by compressed air (fast). Three-point flexural strength tests (FS) were performed on specimens with porcelain under tension (PT, n = 30) and zirconia under tension (ZT, n = 30). Shear bond strength tests (SBS, n = 15) were performed on cylindrical blocks of porcelain, which were applied on zirconia plates. Data were submitted to one-way ANOVA and Tukey's post hoc tests (p < 0.05). Weibull analysis was performed on the PT and ZT configurations.ResultsOne-way ANOVA for the PT configuration was significant, and Tukey's test revealed that fast cooling leads to significantly higher values (p < 0.01) than the other cooling methods. One-way ANOVA for the ZT configuration was not significant (p = 0.06). Weibull analysis showed that normal cooling had slightly higher reliability for both the PT and ZT configurations. Statistical tests showed that slow cooling decreased the SBS value (p < 0.01) and showed less adhesive fracture modes than the other cooling methods.Clinical SignificanceSlow cooling seems to affect the veneer resistance and adhesion to the zirconia core; however, the reliability of fast cooling was slightly lower than that of the other methods.  相似文献   

3.
ObjectivesThe zirconia–resin bond strength was enhanced using novel engineered zirconia primers in combination with selective infiltration etching as a surface pre-treatment. The aim of this study was to evaluate the effect of artificial aging on the chemical stability of the established bond and to understand the activation mechanism of the used primers.MethodsSelective infiltration etched zirconia discs (Procera; NobelBiocare) were coated with one of four novel engineered zirconia primers containing reactive monomers and were bonded to resin-composite discs (Panavia F2.0). Fourier transform infrared spectroscopy (FT-IR) was carried out to examine the chemical activation of zirconia primers from mixing time and up to 60 min. The bilayered specimens were cut into microbars (1 mm2 in cross-section area) and zirconia–resin microtensile bond strength (MTBS) was evaluated immediately and after 90 days of water storage at 37 °C. Scanning electron microscopy (SEM) was used to analyze the fracture surface.ResultsThere was a significant drop in MTBS values after 90 days of water storage for all tested zirconia primers from ca. 28–41 MPa to ca. 15–18 MPa after completion of artificial aging. SEM revealed increase in percentage of interfacial failure after water storage. FTIR spectra suggested adequate activation of the experimental zirconia primers within 1 h of mixing time.SignificanceThe novel engineered zirconia primers produced initially high bond strength values which were significantly reduced after water storage. Long-term bond stability requires developing more stable primers.  相似文献   

4.
ObjectivesTo evaluate the hydrolytic stability of different dual-cure resin cements when luted to zirconia ceramic.MethodsEighteen cylinder-shaped zirconia blocks (Cercon Zirconia, Dentsply) were conditioned with: Group 1, no treatment; Group 2, sandblasting (125 μm alumina–Al2O3-particles); Group 3, tribochemical silica coating (50 μm silica-modified Al2O3 particles). Ceramic blocks were duplicated in composite resin (Tetric Evo Ceram, Ivoclar-Vivadent). Composite disks were luted to pre-treated ceramic surfaces using: (1) Clearfil Esthetic Cement (CEC; Kuraray); (2) Rely X Unicem (RXU; 3M ESPE); (3) Calibra (CAL; Dentsply Caulk). After 24 h, bonded samples were cut into microtensile sticks (1 mm2). Half of the sticks were loaded in tension until failure (cross-head speed of 0.5 mm/min). The remaining half was tested after 6 months of water storage at 37 °C. Data was analyzed with three-way ANOVA and Tukey’s test (P <0.05). Fractographic analysis was performed by SEM.ResultsAfter 24 h, bond strength of CEC to zirconia was significantly higher than that of RXU and CAL, independently from the ceramic pre-treatment (P <0.001). Using CAL, all samples failed prematurely except when luting to sandblasted surfaces. After 6 months of water aging, bond strength of CEC significantly decreased. RXU did not significantly alter bond strengths. Adhesion of sandblasted specimens luted with CAL fell over time. Micromorphological alterations were evident after water storage.SignificanceResin–ceramic interfacial longevity depended on cement selection rather than on surface pre-treatments. CEC and RXU were both suitable for luting zirconia. Water aging played an important role in the durability of zirconia-to-composite chemical bonds.  相似文献   

5.
ObjectivesInformation regarding the effects of orthodontic bracket debonding on zirconia restorations, and the preferred method for residual adhesive removal from the zirconia restoration surface is lacking. Thus, this study aimed to assess the effects of different methods of residual adhesive removal after orthodontic bracket debonding on flexural strength, surface roughness, and phase transformation of high-translucent (HT) zirconia.Materials and methodsThis in vitro study evaluated 72 bar-shaped HT zirconia specimens; 18 specimens were assigned to the control group. Metal brackets were bonded to the remaining specimens by resin cement. After bracket debonding, the residual adhesive on the surface of specimens was removed by three methods (n = 18): a 30-flute tungsten-carbide (TC) bur at low speed, an ultrafine diamond bur at high speed, and Er:YAG laser irradiation. The surface roughness (Ra and Rz) was measured. X-ray diffraction (XRD) analysis was carried out, and the flexural strength was measured as well. Data were statistically analyzed (α = 0.05).ResultsBefore polishing, all methods increased the Ra and Rz values (P < 0.05) except for the diamond bur yielding a Rz value comparable to that of the control group. The Ra values of the test groups were comparable after polishing, and still higher than that of the control group (P < 0.05). The flexural strength of all three test groups was comparable (P > 0.05), and significantly lower than that of the control group (P < 0.001). The monoclinic phase was not observed in any group.ConclusionsOrthodontic bracket debonding adversely affects the surface roughness and flexural strength of zirconia despite polishing.  相似文献   

6.
ObjectivesThe purpose of this study was to evaluate the influence of thermal and mechanical cycling and veneering technique on the shear bond strength of Y-TZP (yttrium oxide partially stabilized tetragonal zirconia polycrystal) core–veneer interfaces.Materials and methodsCylindrical Y-TZP specimens were veneered either by layering (n = 20) or by pressing technique (n = 20). A metal ceramic group (CoCr) was used as control (n = 20). Ten specimens for each group were thermal and mechanical cycled and then all samples were subjected to shear bond strength in a universal testing machine with a 0.5 mm/min crosshead speed. Mean shear bond strength (MPa) was analysed with a 2-way analysis of variance and Tukey's test (p < 0.05). Failure mode was determined using stereomicroscopy and scanning electron microscopy (SEM).ResultsThermal and mechanical cycling had no influence on the shear bond strength for all groups. The CoCr group presented the highest bond strength value (p < 0.05) (34.72 ± 7.05 MPa). There was no significant difference between Y-TZP veneered by layering (22.46 ± 2.08 MPa) or pressing (23.58 ± 2.1 MPa) technique. Failure modes were predominantly adhesive for CoCr group, and cohesive within veneer for Y-TZP groups.ConclusionsThermal and mechanical cycling, as well as the veneering technique does not affect Y-TZP core–veneer bond strength.Clinical significanceDifferent methods of veneering Y-TZP restorations would not influence the clinical performance of the core/veneer interfaces.  相似文献   

7.
ObjectivesTo evaluate the effect of surface conditioning on the microtensile bond strength of zirconium-oxide ceramic to dual-cured resin cements.MethodsEighteen cylinder-shaped zirconium-oxide ceramic blocks (Cercon® Zirconia, Dentsply) were treated as follows: (1) Sandblasting with 125 μm aluminum-oxide (Al2O3) particles; (2) tribochemical silica coating using 50 μm Al2O3 particles modified by silica; (3) no treatment. Each ceramic cylinder was duplicated in composite resin (Tetric Evo Ceram, Ivoclar-Vivadent) using a silicon mold. Composite cylinders were bonded to conditioned ceramics using: (1) Calibra (Densply Caulk); (2) Clearfil Esthetic Cement (Kuraray); (3) Rely × Unicem (3 M ESPE). After 24 h bonded specimens were cut into microtensile sticks that were loaded in tension until failure. Data were analyzed using two-way ANOVA and Student–Newman–Keuls test for multiple comparisons (p < 0.05). Failure mode was recorded and the interfacial morphology of debonded specimens was observed using a scanning electron microscope (SEM). Surface topography and ceramic average surface roughness were analyzed under an atomic force microscope (AFM).ResultsSignificant changes in zirconia surface roughness occurred after sandblasting (p < 0.001). Bond strength of Clearfil cement to zirconia was significantly higher than that of Rely × Unicem and Calibra, regardless of the surface treatment (p < 0.001). When using Calibra, premature failures occurred in non-treated and silica coated zirconia surfaces.SignificanceThe phosphate monomer-containing luting system (Clearfil Esthetic Cement) is recommended to bond zirconia ceramics and surface treatments are not necessary.  相似文献   

8.
ObjectivesThe purpose of this study was to evaluate the bond strength of commercially pure CPTi and Ti6Al4V alloy with SiO2 and SiO2–TiO2 intermediate coatings to Triceram low-fusing dental porcelain.MethodsThe multilayered systems were characterized from the standpoint of microstructure analysis (SEM), the mode of failure, the nature of bonding and the influence of intermediate coatings on the improvement of bond strength. The SiO2 and SiO2–TiO2 intermediate coatings were applied on the substrate materials by the sol–gel dipping technique. The metal–ceramic bond strength was investigated according to ISO 9693 standards using the three-point flexure bond test.ResultsStatistically significant higher bond strength of the metal–porcelain for Ti6A14V alloy (28.24 MPa), Ti6Al4V/SiO2 (32.17 MPa) and Ti6Al4V/SiO2–TiO2 (36.09 MPa) was noted in comparison to CPTi (23.04 MPa), CPTi/SiO2 (27.98 MPa) and CPTi/SiO2–TiO2 (28.84 MPa), respectively. The nature of metal-intermediate coating–porcelain bonding was both mechanical and chemical. The failure in all systems was cohesive and adhesive, mainly adhesive.SignificanceThe application of SiO2 and SiO2–TiO2 intermediate coatings, produced by the sol–gel method, to both CPTi and Ti6Al4V alloy significantly improves the bond strength of metal–porcelain systems in comparison to the metal substrate only after sandblasting, and may have clinical use.  相似文献   

9.
《Dental materials》2020,36(7):905-913
ObjectivesDifferent approaches are currently undertaken to structure the endosseous part of zirconia implants. The purpose of the present study was to evaluate how surface roughness and monoclinic to tetragonal phase ratio of zirconia affect cell behavior of human osteoblasts.MethodsZirconia discs with five different surface structures were produced: machined; machined heat-treated; polished; polished heat-treated; sandblasted, etched and heat-treated (cer.face 14, vitaclinical). The specimen surfaces were then characterized in terms of monoclinic to tetragonal phase ratio, wettability, roughness and visualized using scanning electron microscopy. To determine the reaction of the human osteoblastic cells (MG-63) to the surface roughness and monoclinic to tetragonal phase ratio of zirconia, cell spreading, morphology, actin cytoskeleton, viability and gene expression of alkaline phosphatase (ALP), collagen type I (COL) and osteocalcin (OCN) were assessed.ResultsHeat-treatment of the specimens significantly improved the surface wettability. With increased surface roughness Ra of the specimens, cell spreading was reduced. Cell viability after 24 h correlated linearly with the tetragonal phase ratio of the specimens. Gene expression after 24 h and 3 d was comparable on all specimens irrespective their surface roughness or monoclinic to tetragonal phase ratio.SignificanceSmooth zirconia surfaces with a high tetragonal phase ratio revealed best surface conditions for MG-63 osteoblastic cells and may be considered to design the endosseous part of zirconia implants.  相似文献   

10.
PurposeThis study examined the wear resistance of human enamel and feldspathic porcelain after simulated mastication against 3 zirconia ceramics, heat-pressed ceramic and conventional feldspathic porcelain.Materials and methodsHuman teeth and feldspathic porcelain cusp were tested against ceramic discs. 5 brands were tested – 3 monolithic zirconia, Prettau, Lava, and Rainbow, one lithium disilicate, IPS e.max Press, and one feldspathic porcelain, Vita-Omega 900. The surface was polished using a 600 grit and 1200 grit SiC paper. Each group was loaded for 300,000 cycles in a chewing simulator. The wear resistance was analyzed by measuring the volume of substance lost. The wear surfaces were observed by scanning electron microscopy to determine the wear characteristics.ResultsVita-Omega 900 led to the greatest amount of enamel wears followed by IPS e.max Press, Prettau, Lava and Rainbow. There was a significant difference between Vita-Omega 900 and IPS e.max Press (p < 0.05). The wear values for human enamel were significantly greater than those for feldspathic porcelain, regardless of the surface roughness of the ceramic specimens (p < 0.05).ConclusionThe wear behaviour of human enamel and feldspathic porcelain varies according to the type of substrate materials. On the other hand, 3 zirconia ceramics caused less wear in the abrader than the conventional ceramic.Clinical significanceDental professionals should be aware of the wear effect of dental restorations on the opposing teeth or restorations. The amount of enamel wear was highest in feldspathic porcelains whereas zirconia ceramics caused less wear on the opposing teeth.  相似文献   

11.
目的:探讨采用改良液式冲蚀方式对3Y-TZP氧化锆基底表面进行冲蚀后,对其与饰面瓷间结合强度的影响.方法:制作[8 mm×8 mm×3 mm(±0.02)]氧化锆试件块174个,根据不同尺寸的刚玉磨粒、不同的喷砂压强、不同的喷砂时间,采用传统喷砂方式进行分组处理(实验组),在氧化锆处理面上饰面瓷.表面未做处理的氧化锆试件直接上饰面瓷作为对照组,应用电子万能测力计检测各组试件与饰面瓷间的最大剪切力,计算剪切强度.分别用传统干式喷砂、改良液式冲蚀方式在相同条件下(150 μm,0.6 MPa,30 s)处理氧化锆试件块,用扫描电镜下观察处理面,再上饰面瓷,计算剪切强度,与对照组进行组间比较.采用SPSS17.0软件包对数据进行统计学分析.结果:采用传统干式喷砂方式,在0.4 MPa压强作用下,以110 μm A12O3喷砂粉喷砂20 s时,氧化锆与饰面瓷之间的剪切强度最大,显著大于对照组(P<0.05);改良液式冲蚀组饰面瓷的结合强度显著大于传统干式喷砂处理组及对照组(P<0.01).扫描电镜下可见,采用改良液式冲蚀的试件表面呈现均匀的粗糙面:采用传统干式喷砂处理的试件表面呈现不均匀的粗糙面,部分位置可见微裂纹.结论:对3Y-TZP氧化锆表面喷砂,能够增强其与饰面瓷间的结合强度;改良液式冲蚀比传统干式喷砂更适用于3Y-TZP氧化锆的表面处理.  相似文献   

12.
ObjectiveFor long-term stability the adhering interfaces of an implant-retained supraconstruction of titanium/carbon–graphite fiber-reinforced (CGFR) polymer/opaquer layer/denture base polymer/denture teeth must function as a unity. The aim was to evaluate adhesion of CGFR polymer to a titanium surface or CGFR polymer to two different opaquer layers/with two denture base polymers.Materials and methodsTitanium plates were surface-treated and silanized and combined with a bolt of CGFR polymer or denture base polymer (Probase Hot). Heat-polymerized plates of CGFR polymer (47 wt% fiber) based on poly(methyl methacrylate) and a copolymer matrix were treated with an opaquer (Sinfony or Ropak) before a denture base polymer bolt was attached (Probase Hot or Lucitone 199). All specimens were heat-polymerized, water saturated (200 days) and thermally cycled (5000 cycles, 5/55 °C) before shear bond testing.ResultsSilicatized titanium surfaces gave higher bond strength to CGFR polymer (16.2 ± 2.34 and 18.6 ± 1.32) MPa and cohesive fracture than a sandblasted surface (5.9 ± 2.11) MPa where the fracture was adhesive. The opaquer Sinfony gave higher adhesion values and mainly cohesive fractures than the opaquer Ropak. Different surface treatments (roughened or polished) of the CGFR polymer had no effect on bond strength.SignificanceThe fracture surfaces of silicatized titanium/CGFR polymer/opaquer layer (Sinfony)/denture base polymers were mainly cohesive. A combination of these materials in an implant-retained supraconstruction is promising for in vivo evaluation.  相似文献   

13.
《Dental materials》2019,35(10):1498-1505
ObjectivesUnderstand how cooling protocols control the microstructure and mechanical properties of veneering porcelains.MethodsTwo porcelain powders were selected, one used to veneer metallic frameworks (VM13) and one for zirconia frameworks (VM9). After the last firing cycle, the monolithic specimens were subjected to two cooling protocols: slow and fast. Flexural strength (FS) was evaluated by three-point beam bending and fracture toughness (KIC) was evaluated by the single-edge V-notch beam (SEVNB) method. Scanning electron microscopy (SEM) was performed to determine the leucite crystal volume fraction (%), particle size, and matrix microcrack density. The results were compared by analysis of variances (ANOVA) and Tukey’s multiple comparison test.ResultsThe mechanical properties were significantly (p < 0.05) higher for the VM13 porcelain (FS = 111.0 MPa, KIC = 1.01 MPa.√m) compared to VM9 (FS = 79.6 MPa, KIC =0.87 MPa.√m) regardless of cooling protocol due to ∼250% higher volume fraction of leucite crystals. The slow cooled VM13 and fast cooled VM9 resulted in the highest and lowest mechanical properties, respectively, while the VM9 slow cooled properties were similar to the VM13 fast cooled. The SEM revealed that the slow cooling significantly increased the volume fraction of leucite crystals by 33–41 %. Across both porcelains, a significant linear correlation between both mechanical properties (strength and toughness) and leucite crystal content was found. Slow cooling was also associated with increased crystal growth resulting in more matrix microcracking.SignificanceControlled crystallization using slow cooling can be applied as a means of strengthening dental porcelains. However, the benefits of slow cooling may be partially offset by increasing the microcrack density in the glass matrix. To achieve the maximum benefit of slow cooling, it is recommending to develop heat treatments to produce porcelain with fine-grained and homogenously dispersed leucite crystals to achieve minimal glass matrix microcracking.  相似文献   

14.
《Dental materials》2020,36(4):e126-e139
ObjectiveTo investigate the effect of different surface finishing and polishing regimes and low temperature degradation on flexural strength, phase transformation and surface topography of ultra-translucent ZrO2 ceramic.Methods300 (n = 15/group) of conventional zirconia (Z: Ice Zirkon Transluzent) and ultra-translucent zirconia (UT: Prettau Anterior) bar-specimens were made and divided according to the "Finishing/Polishing" - (C — Control, B — diamond rubber polishers, P — adjusting with burs, PB — adjusting with burs + diamond polishers, PG — adjusting with burs + glaze), "Low temperature Degradation (LTD)" (with or without a treatment at 127 °C, 1.7 bar/24 h). Then, a 3-point mini flexural test was performed in a universal testing machine (1 mm/min, 500 kgf load cell). SEM, EDS, XDR, AFM, optical profilometry and Weibull analysis were performed. Data were analyzed by 3-way ANOVA and Tukey’s post-test (5%).ResultsGroups ZPBD (1670 ± 253 MPa), ZBD (1664 ± 217 MPa), and ZB (1655 ± 3678 MPa) showed significantly higher flexural strength than the UTPG group (372 ± 56 MPa). The Weibull modulus was significantly higher for the ZPD group compared to the UB, UCD, UPD and UPBD, while UTB, UTCD and UTPD had the lowest value. Monoclinic phases were observed only in the conventional zirconia groups and were more evident after LTD. Diamond rubber polishers presented less roughness for both zirconias.SignificanceThe use of diamond rubber polishers is the most suitable finishing/polishing method for zirconia ceramic restorations and that final glazing reduces the fracture resistance of these materials.  相似文献   

15.
《Dental materials》2019,35(12):1776-1790
ObjectivesTo evaluate two-body wear of three zirconia ceramics stabilized with 3, 4 and 5 mol% yttria and to compare their wear behavior with that of a lithium-disilicate glass-ceramic.MethodsSixteen rectangular-shaped specimens made from three grades of zirconia ceramics and a lithium-disilicate glass-ceramic were polished and dynamically loaded in a chewing simulator (2 kg vertical load, 2.1 Hz) under water at 90 °C for 1.2 × 106 cycles (about 7 days) in the ball-on-plate mode against steatite antagonists. Surface roughness was measured before and after wear testing. Wear tracks were scanned with a non-contact 3D profilometer and super-impositions were used to determine wear loss of the antagonists. Wear surfaces were imaged by SEM. XRD and micro-Raman spectroscopy were used to characterize phase transformation and stress status in the worn and unworn areas of the zirconia ceramics.ResultsIndependent of fracture toughness, strength and aging-susceptibility, the three zirconia ceramics showed a similar and limited amount of wear (∼10 μm in depth) and were more wear-resistant than the lithium-disilicate glass-ceramic (∼880 μm in depth). Abrasive wear without obvious cracks was observed for all investigated zirconias, whereas the glass-ceramic with a lower fatigue threshold and high susceptibility to surface dissolution exhibited significant abrasion, fatigue and corrosion wear. All three zirconia ceramics yielded a lower antagonist wear than the glass-ceramic and no significant differences were found between the zirconia ceramics.SignificanceIn the context of this study, high-translucent zirconia ceramics stabilized with a higher yttria content, recently introduced in the dental field, were as wear-resistant and antagonist-friendly as conventional high-strength zirconia and suitable for monolithic restorations.  相似文献   

16.
《Dental materials》2014,30(12):e396-e404
ObjectiveTo determine the effects of different aging methods on the degradation and flexural strength of yttria-stabilized tetragonal zirconia (Y-TZP)MethodsSixty disc-shaped specimens (, 12 mm; thickness, 1.6 mm) of zirconia (Vita InCeram 2000 YZ Cubes, VITA Zahnfabrik) were prepared (ISO 6872) and randomly divided into five groups, according to the aging procedures (n = 10): (C) control; (M) mechanical cycling (15,000,000 cycles/3.8 Hz/200 N); (T) thermal cycling (6,000 cycles/5–55 °C/30 s); (TM) thermomechanical cycling (1,200,000 cycles/3.8 Hz/200 N with temperature range from 5 °C to 55 °C for 60 s each); (AUT) 12 h in autoclave at 134 °C/2 bars; and (STO) storage in distilled water (37 °C/400 days). After the aging procedures, the monoclinic phase percentages were evaluated by X-ray diffraction (XRD), and topographic surface analysis was performed by 3D profilometry. The specimens were then subjected to biaxial flexure testing (1 mm/min, load 100 kgf, in water). The biaxial flexural strength data (MPa) were analyzed by 1-way ANOVA and Tukey's test (α = 0.05). The data for monoclinic phase percentage and profilometry (Ra) were analyzed by Kruskal–Wallis and Dunn's tests.ResultsANOVA revealed that flexural strength was affected by the aging procedures (p = 0.002). The M (781.6 MPa) and TM (771.3 MPa) groups presented lower values of flexural strength than did C (955 MPa), AUT (955.8 MPa), T (960.8 MPa) and STO (910.4 MPa). The monoclinic phase percentage was significantly higher only for STO (12.22%) and AUT (29.97%) when compared with that of the control group (Kruskal–Wallis test, p = 0.004). In addition, the surface roughnesses were similar among the groups (p = 0.165).SignificanceWater storage for 400 days and autoclave aging procedures induced higher phase transformation from tetragonal to monoclinic; however, they did not affect the flexural strength of Y-TZP ceramic, which decreased only after mechanical and thermomechanical cycling.  相似文献   

17.
PurposeTo investigate the effects of using a low-cost powered toothbrush for cleaning on dental prostheses made of heat polymerized poly(methyl methacrylate), PMMA.MethodsHeat cured PMMA specimens beam with the dimensions of 45.0 mm × 6.5 mm × 4.5 mm were fabricated. The specimens were kept in water storage at 37 °C constant temperature for 0, 1, 7, 15, 30 and 60 days and randomly assigned for testing or control. Test specimens underwent brushing by using a powered toothbrush at an applied force of 2.00 N for 22 min with water as medium. Surface roughness measurement (Ra), flexural strength and efficacy of brushing to remove coated Candida albicans biofilm were investigated.ResultsThe results of the mean surface roughness value and the flexural strength were analysed by using two-way ANOVA and Tukey post hoc test at 5% significance level. In general, the specimens showed no significant changes in flexural strength after brushing. However, the flexural strength and the surface roughness value were significantly lower in specimens group after 7 days in water storage compared to the control. SEM micrographs of post-brushed specimens revealed satisfactory removal of C. albicans biofilm.ConclusionA low-cost powered toothbrush together with a liquid medium successfully removed C. albicans biofilm on dental acrylic PMMA-based prostheses, without compromising the mechanical properties.  相似文献   

18.
目的 研究氧化铝(Al2O3)喷砂对牙科用氧化锆基底与饰面瓷结合强度的影响。方法 按照ISO 9693的要求,制作(25±1) mm×(3±0.1) mm×(0.5±0.05) mm的片状氧化锆试样21个,随机分为3组:A组进行110目Al2O3喷砂;B组进行80目Al2O3喷砂;对照组不做喷砂处理。测定所有基底瓷的表面粗糙度以及基底瓷与饰面瓷的结合强度,扫描电镜(SEM)观察结合界面微观形貌,能谱分析(EDS)检测界面元素分布。结果 A组、B组和对照组基底瓷表面粗糙度分别为(1.272±0.149)、(0.622±0.113)、(0.221±0.065) μm;瓷瓷结合强度分别为(28.21±1.52)、(27.71±1.27)、(24.87±3.84) MPa。统计结果显示:各组间表面粗糙度的差异具有统计学意义(P<0.05);A组和对照组之间结合强度的差异具有统计学意义(P<0.05),而B组与A组和对照组之间的差异均无统计学意义(P>0.05)。破坏模式以结合界面附着破坏为主。SEM观察结果显示瓷瓷结合界面结合紧密,EDS结果表明界面无明显元素渗透现象。结论 Al2O3喷砂能提高基底瓷与饰面瓷的结合强度,但其作用不明显。  相似文献   

19.
ObjectivesTo determine the effect of ion exchange on slow crack growth (SCG) parameters (n, stress corrosion susceptibility coefficient, and σf0, scaling parameter) and Weibull parameters (m, Weibull modulus, and σ0, characteristic strength) of a dental porcelain.Methods160 porcelain discs were fabricated according to manufacturer's instructions, polished through 1 μm and divided into two groups: GC (control) and GI (submitted to an ion exchange procedure using a KNO3 paste at 470 °C for 15 min). SCG parameters were determined by biaxial flexural strength test in artificial saliva at 37 °C using five constant stress rates (n = 10). 20 specimens of each group were tested at 1 MPa/s to determine Weibull parameters. The SPT diagram was constructed using the least-squares fit of the strength data versus probability of failure.ResultsMean values of m and σ0 (95% confidence interval), n and σf0 (standard deviation) were, respectively: 13.8 (10.1 ? 18.8) and 60.4 (58.5 ? 62.2), 24.1 (2.5) and 58.1 (0.01) for GC and 7.4 (5.3 ? 10.0) and 136.8 (129.1 ? 144.7), 36.7 (7.3) and 127.9 (0.01) for GI. Fracture stresses (MPa) calculated using the SPT diagram for lifetimes of 1 day, 1 year and 10 years (at a 5% failure probability) were, respectively, 31.8, 24.9 and 22.7 for GC and 71.2, 60.6 and 56.9 for GI.SignificanceFor the porcelain tested, the ion exchange process improved strength and resistance to SCG, however, the material's reliability decreased. The predicted fracture stress at 5% failure probability for a lifetime of 10 years was also higher for the ion treated group.  相似文献   

20.
目的探讨计算机辅助设计/计算机辅助制造(CAD/CAM)切削表面形貌对氧化锆瓷与饰瓷结合强度的影响。方法将40个Upcare氧化锆基底材料以CAD/CAM切削烧结瓷块试件,随机等分为4组。其中对照组按常规操作进行打磨、喷砂及抛光等处理。实验组均采用CAD/CAM时预设程序,分别使切削产生的刀路与剪切强度测试加力方向呈垂直(A组)、平行(B组)及突起(C组),并对试件进行喷砂处理。测量并比较各组试件的表面粗糙度和剪切强度。扫描电镜观察断裂界面的情况。结果各组的剪切强度分别为:A组(27.64±4.24)MPa、B组(27.12±5.32)、C组(36.86±7.21)MPa、对照组(24.14±2.74)MPa,其中对照组与A组、B组之间差异均无统计学意义(P>0.05),对照组与C组之间的差异具有统计学意义(P<0.05)。各组的表面粗糙度分别为:A组(5578.34±1165.58)Ra、B组(5227.98±1440.29)Ra、C组(5699.97±1234.28)Ra、对照组(5964.92±1013.834)Ra,各组之间的差异无统计学意义(P>0.05)。Pearson相关性分析显示,试件表面粗糙度与剪切强度之间无线性相关关系(P>0.05)。扫描电镜观察显示C组较其他组氧化锆瓷与饰瓷结合更致密,未见气泡,无孔隙存在。结论固位突起的锆瓷表面形貌可有效增加锆瓷与饰瓷间的结合强度,而表面粗糙度对界面的结合强度无明显影响。  相似文献   