首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We report five life-threatening anaphylactoid reactions occurring within the very first minutes of hemodialysis on polyacrylonitrile (AN69) capillary dialyzers in three patients receiving ACE inhibitors. Such reactions were not observed either in patients treated with ACE inhibitors but dialyzed on other membranes (N = 9), nor in patients on AN69 who did not receive ACE inhibitors (N = 19). These anaphylactoid reactions could be due to bradykinin accumulation, as a result of both increased synthesis--by interaction of blood with the AN69 polymer--and catabolism blockade by ACE inhibitors.  相似文献   

2.
3.
Over a 20-month period, we observed 15 anaphylactoid reactions in six patients undergoing hemodialysis and three others on hemofiltration with AN69 capillary dialyzers who were receiving angiotensin-converting enzyme (ACE) inhibitors. These reactions were severe in 11 cases. In eight patients, anaphylactoid reactions stopped when AN69 membrane was replaced by polysulfone membrane and ACE inhibitors were continued. In one case, reducing the dose of ACE inhibitors was sufficient to prevent new reactions. Anaphylactoid reactions did not occur in patients undergoing dialysis with another membrane (cellulosic or synthetic), nor in those on AN69 membrane without ACE inhibitor treatment. We conclude that back-filtration of endotoxin-contaminated dialysate does not play the main role in the origin of such reactions, since they occurred in patients on hemofiltration with sterile and pyrogen-free substitution liquids.  相似文献   

4.
Anaphylactoid reactions from blood contact with AN69 hemodialysis membrane in patients taking ACE inhibitors are well-known. Modified AN69 dialyzers (ST-AN69) were invented to create a membrane combining low thrombogenic properties with safety with ACE inhibitors. We report four patients taking ACE inhibitors that presented anaphylactoid reactions with ST-AN69.  相似文献   

5.
Sir, Anaphylactoid reactions during haemodialysis using AN69 membranein patients receiving angiotensin-converting enzyme inhibitors(ACEI) are well recognized [1]. However, to our knowledge, anaphylactoidreactions induced by ACEI during haemodialysis with a surface-treatedAN69 membrane have not been reported so far. We report on apatient who experienced an anaphylactoid reaction while dialysingon surface-treated AN69 membrane and received a single doseof captopril. Case A 49-year-old male with  相似文献   

6.
Anaphylactoid reactions after cisatracurium administration in six patients.   总被引:3,自引:0,他引:3  
IMPLICATIONS: We report six cases of anaphylactoid reaction after the administration of the muscle relaxant cisatracurium. They include two first-time documented anaphylactoid reactions after a precurarising dose. These incidents challenge existing views of a substantially reduced anaphylactoid potential of cisatracurium relative to other muscle relaxants.  相似文献   

7.
8.
One hundred eleven chronic hemodialysis patients from five dialysis units were tested for the presence of antibodies reactive with red blood cell N substance; 77 patients were available for follow-up study after 18 to 24 months. Initially, 18 patients (16%) had serum anti-N-like antibodies. Thirteen of these patients were in a home dialysis program and were reusing hollow fiber dialyzers. The other five had practiced hollow fiber dialyzer reuse in the past. None of 37 patients using coil dialyzers had anti-N-like antibody. On follow-up testing, anti-N-like antibody persisted in all patients restudied except for one who had a successful renal transplant. Anti-N-like antibodies developed in four additional patients: three were reusing hollow fiber dialyzers at the time, but one had not reused dialyzers for 24 months. Statistical analyses indicated that dialyzer reuse, hollow fiber dialyzers, and home dialysis were significantly related to the presence of anti-N-like antibodies. We interpret the clinical and statistical data to indicate that dialyzer reuse is the major clinical factor in the development of anti-N-like antibody. The likely mechanism involves the prolonged exposure of red cells trapped in the dialyzer to formaldehyde used in preparing dialyzers for reuse. No adverse clinical effects of anti-N-like antibodies were evident in our patients, but hemolysis and acute transplant failure have been reported by others.  相似文献   

9.
Ascites in patients treated with maintenance hemodialysis   总被引:2,自引:0,他引:2  
  相似文献   

10.
11.
12.
13.
OBJECTIVES: To determine if reuse of hemodialyzers is associated with higher rates of hospitalization and their resulting costs among end-stage renal disease (ESRD) patients. METHODS: Noncurrent cohort study of hospitalization rates among 27,264 ESRD patients beginning hemodialysis in the United States in 1986 and 1987. RESULTS: Dialysis in free-standing facilities reprocessing dialyzers was associated with a greater rate of hospitalization than in facilities not reprocessing (relative rate (RR) = 1.08, 95% confidence interval (CI), 1.02-1.14). This higher rate of hospitalization was observed with dialyzer reuse using peracetic/acetic acids (RR = 1.11, CI 1. 04-1.18) and formaldehyde (RR = 1.07, CI 1.00-1.14), but not glutaraldehyde (p = 0.97). There was no difference among hospitalization rates in hospital-based facilities reprocessing dialyzers with any sterilant and those not reprocessing. Hospitalization for causes other than vascular access morbidity in free-standing facilities reusing dialyzers with formaldehyde was not different from hospitalization in facilities not reusing. However, reuse with peracetic/acetic acids was associated with higher rates of hospitalization than formaldehyde (RR = 1.08, CI 1.03-1.15). CONCLUSIONS: Dialysis in free-standing facilities reprocessing dialyzers with peracetic/acetic acids or formaldehyde was associated with greater hospitalization than dialysis without dialyzer reprocessing. This greater hospitalization accounts for a large increment in inpatient stays in the USA. These findings raise important concerns about potentially avoidable morbidity among hemodialysis patients. Copyright Copyright 1999 S. Karger AG, Basel  相似文献   

14.
15.
A major adverse effect of recombinant human erythropoietin (r-HuEPO) in hemodialyzed patients are thrombotic events. Several reports on platelet function during r-HuEPO treatment have been published but less is known about fibrinolysis. In the present study, the fibrinolytic capacity was studied in 20 patients on maintenance hemodialysis and treated with r-HuEPO. The patients were randomized into two groups and investigated in a crossover design. r-HuEPO was administered intravenously and subcutaneously in each group and was given for 3 months, respectively. Plasma tissue plasminogen activator (t-PA) and released t-PA remained unaffected by r-HuEPO in both groups throughout the study. Tissue plasminogen activator inhibitor (PAI) increased in a cyclic way reaching peak values 4-6 weeks after the start of investigation and again 4-6 weeks after changing therapy. The increase in PAI was significant in the two groups (0.025 > p > 0.01). Tissue plasminogen antigen was low in the uremic patients. The influence of r-HuEPO on this parameter was not investigated. Compensatory changes in plasma levels of factor XII procoagulant activity, activated protein C and of alpha 2-antiplasmin were not observed. Thrombotic events occurred in 4 patients at peak values of PAI. Six patients required an increase in heparin dose simultaneously with the increase in PAI. Thus, r-HuEPO seemed to affect the fibrinolytic capacity of uremic patients.  相似文献   

16.
The peracetic acid-based sterilant Renalin is increasingly being used for reprocessing hemodialyzers. In order to evaluate the effects of reprocessing on beta 2-microglobulin (beta 2M) kinetics and complement activation in chronic hemodialysis patients, we compared 4 dialyzer membranes on 1st, 2nd and 4th use of the membrane. Dialysis with new cuprammonium rayon dialyzers (0.8 m2) for 4 h resulted in a nonsignificant increase in serum beta 2M concentrations of 10.7% (corrected for changes in extracellular volume) and significant generation of the complement component C3a des Arg. On reuse, minimal changes in serum beta 2M levels were noted and complement activation was absent. Dialysis with new cellulose acetate (CA, 1.5 m2), polyacrylonitrile (AN69 HF, 1.6 m2) or polymethylmethacrylate (PMMA, 1.6 m2) membranes resulted in significant decreases in serum beta 2M levels (19.5, 31.7 and 50.8%, respectively). Reprocessing had negligible effects on the removal of beta 2M by CA and AN69, but by the 4th use halved the effectiveness of PMMA. Reprocessing reduced the significant generation of C3a des Arg observed with new CA and PMMA membranes. We conclude that, except for PMMA, Renalin reprocessing has minor effects on the ability of the membranes to remove beta 2M and improves the biocompatibility of all membranes studied.  相似文献   

17.
《Renal failure》2013,35(10):1148-1152
Pulmonary hypertension (PHT) increases mortality rate in hemodialysis (HD) patients. Numerous clinical, hemodynamic, and metabolic abnormalities have been suggested to be associated with the development of PHT in HD patients. We aimed to investigate the acute effects of two different dialyzer membranes on pulmonary arterial pressure (PAP) throughout a HD session in maintenance HD patients. Seventy-four HD patients dialyzed through permanent tunneled jugular central venous catheter were enrolled. A first-use cellulose acetate and high-flux polysulfone dialysis membrane were tested using a crossover design. For each membrane, pre- and post-dialysis pulmonary artery pressures were measured echocardiographically. Elevated pulmonary artery pressure was observed in 68.8% of patients (n = 51), whereas mild PHT was observed in 28.3% of patients (n = 21) and moderate PHT in 40.5% (n = 30). Decrease in pulmonary artery pressure following HD procedure performed using high-flux polysulfone membrane was significantly higher than the decrease observed following HD procedure performed using cellulose acetate membrane (p < 0.05). Significant decrease in pulmonary artery pressures was observed only after HD procedures performed using high-flux polysulfone membrane (p < 0.05). Ultrafiltered volume was only significantly correlated with the decrease in pulmonary artery pressure observed after HD procedure performed through high-flux polysulfone membrane (β = 0.411, p < 0.05). PHT seems to be prevalent among HD patients even in the absence of AV fistula and abnormal cardiac functions. Membrane composition seems to be important, which may overwhelm the improving effects of ultrafiltration.  相似文献   

18.
Evaluation of hemodialysis patients treated with erythropoietin   总被引:1,自引:0,他引:1  
We evaluated 20 hemodialysis patients who had been treated with erythropoietin (Epo). All patients had hemoglobin levels below 8.5 g/dL. They were randomized to receive either Epo (100 U/kg) or placebo three times per week for 12 weeks. All patients on Epo had a significant (P less than 0.001) elevation of hematocrit levels (19.7% v 35.7%). They also had a significant (P less than 0.05) increase in midweek predialysis blood urea nitrogen (BUN) levels, 27.8 versus 29.6 mmol/L (78 v 83 mg/dL), and serum phosphorus, 1.8 versus 2.1 mm/L (5.7 v 6.6 mg/dL). Protein catabolic rate also increased significantly (P less than 0.05). No changes were seen in the levels of serum creatinine and potassium, but episodes of hyperkalemia were more frequent in patients on Epo. No changes were seen in patients on placebo. When hematocrit increased, the clearance of blood-water for urea decreased 9%, and the clearance of creatinine, potassium, and phosphorus decreased 15%. Patients on Epo increased both their appetite and protein intake. More frequent episodes of hyperkalemia and elevated phosphorus level resulted from a combination of increased intake and decreased dialyzer clearance. We may need blood-water clearance to calculate Kt/V.  相似文献   

19.
Incompatibility reactions due to hydroxyethyl starch (HES) were observed during 8 out of 10,273 infusions of 500 ml 6% HES (Plasmasteril). The clinical symptoms ranged from skin reactions to tachycardia, hypotension and shock. In 3 of the 8 patients with incompatibility serum immunoglobulin concentrations were reduced after the anaphylactoid reaction. Specific antibodies against HES were, however, not detected. Serum IgE levels stayed within their normal limits. Positive reactions of the immediate type to intradermal skin tests with different dilutions of Plasmasteril were obtained in five patients.  相似文献   

20.
Kiykim AA  Horoz M  Ozcan T  Yildiz I  Sari S  Genctoy G 《Renal failure》2010,32(10):1148-1152
Pulmonary hypertension (PHT) increases mortality rate in hemodialysis (HD) patients. Numerous clinical, hemodynamic, and metabolic abnormalities have been suggested to be associated with the development of PHT in HD patients. We aimed to investigate the acute effects of two different dialyzer membranes on pulmonary arterial pressure (PAP) throughout a HD session in maintenance HD patients. Seventy-four HD patients dialyzed through permanent tunneled jugular central venous catheter were enrolled. A first-use cellulose acetate and high-flux polysulfone dialysis membrane were tested using a crossover design. For each membrane, pre- and post-dialysis pulmonary artery pressures were measured echocardiographically. Elevated pulmonary artery pressure was observed in 68.8% of patients (n = 51), whereas mild PHT was observed in 28.3% of patients (n = 21) and moderate PHT in 40.5% (n = 30). Decrease in pulmonary artery pressure following HD procedure performed using high-flux polysulfone membrane was significantly higher than the decrease observed following HD procedure performed using cellulose acetate membrane (p < 0.05). Significant decrease in pulmonary artery pressures was observed only after HD procedures performed using high-flux polysulfone membrane (p < 0.05). Ultrafiltered volume was only significantly correlated with the decrease in pulmonary artery pressure observed after HD procedure performed through high-flux polysulfone membrane (β = 0.411, p < 0.05). PHT seems to be prevalent among HD patients even in the absence of AV fistula and abnormal cardiac functions. Membrane composition seems to be important, which may overwhelm the improving effects of ultrafiltration.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏