首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Coexistent sino-atrial and atrioventricular block with Wenckebach phenomenon is an extremely unusual cardiac arrhythmia. Observations on the natural history of sinus node dysfunction are rare. For over six years our elderly patient has been followed without symptoms but with increasing severity of atrio-ventricular block.  相似文献   

2.
BACKGROUND--The report from the Working Party of the British Pacing and Electrophysiology Group recommends the use of more sophisticated pacemakers in most patients. These proposals were initially circulated in September 1990 and are likely to have major cost implications. Their impact on pacing practice and the immediate costs of pacemaker hardware in the Northern Region were retrospectively audited. METHODS--The pacing records of 550 patients undergoing a first pacemaker insertion at the Freeman Hospital between March 1990 and August 1991 were reviewed. The patient's age, indication for pacing, pacing mode, and the cost of generator and lead(s) were recorded. The cost was compared with the costs of pacing with the optimal and alternative modes recommended by the Working Party. The costs were calculated from the actual mean cost of the recommended unit over the 18 month period of study multiplied by the number of patients who would have received that unit. RESULTS--96% of patients were paced for sinus node dysfunction, atrioventricular block, or atrioventricular block and atrial fibrillation. The mean (SD) ages of patients in each diagnostic group were: sinus node dysfunction 69.4 (14), sinus node disease and atrioventricular block 67.2 (17.6), atrioventricular block 73.9 (12.5), atrial fibrillation and atrioventricular block 74.0 (13.9), and carotid sinus hypersensitivity 74.6 (11.6) years. Over the 18 month audit period there was an increase in physiological pacing. AAI pacing in patients with sinus node dysfunction increased by 100% and DDD pacing in atrioventricular block increased by atrioventricular block increased by 56%. Over the whole 18 month period the adoption of the British Pacing and Electrophysiology Groups optimal recommendations would have increased expenditure on pacemaker hardware in the Northern Region by 94% and the use of the alternative mode would have increased it by 61%. For the last six months alone the excess would be 78% and 48%. CONCLUSIONS--The adoption of the recommendations of the British Pacing and Electrophysiology group in the Northern Region would greatly increase the cost of pacing hardware. The greater part of this increase would be attributable to the routine use of dual chamber pacing in patients with atrioventricular block and the increased use of rate responsive units. The benefits of sophisticated pacing in a predominantly elderly population need to outweigh the disadvantages of the increased cost and complexity of follow up.  相似文献   

3.
Disorders of rhythm or conduction in patients with transposition of the great arteries (TGA) after the Mustard operation have been widely reported. This study provides a systematic evaluation of the electrophysiologic function of 87 survivors of the Mustard operation at a single institution. Surface electrocardiograms were reviewed in all 87 patients, Holter monitoring data in 26 patients, exercise electrocardiograms in 21 patients, and invasive electrophysiologic data in 61 patients. Surface electrocardiograms showed normal sinus rhythm in 52%, sinus node dysfunction in 27%, and atrioventricular block in 16%. Holter monitoring was obtained in an unselected subgroup of 26 patients who had a mean age of 12 years and a mean interval from operation of 9 years. Sinus node dysfunction was found in 58%, atrioventricular block in 27% ventricular ectopy in 50%, supraventricular ectopy in 27%, and no abnormalities in only 8%. Intracardiac electrophysiologic evaluation showed a high frequency of abnormal sinus node recovery times and suboptimal response of the atrioventricular-conduction system to rapid atrial pacing. When all modalities used in this study were considered, sinus node dysfunction occurred in 47%, ectopy in 34% and atrioventricular block in 23%. Although only 30% of patients had no evidence of arrhythmia, symptoms of rhythm or conduction disturbances were rare.  相似文献   

4.
The dual-chamber pacing systems allow for AV synchrony, but generally require the placement of two separate transvenous leads. Single-lead atrioventricular synchronous pacing system (VDD) using single-pass leads has been accepted as therapeutic alternative for atrioventricular block with normal sinus node function. The aim of this study is to evaluate clinical performance of single-pass lead VDD pacing systems in 24 consecutive patients in a ten-year period. The study group includes 17 (70.8%) male and 7 (28.8%) female patients.The mean age and mean weight during pacemaker implantation was 10.4 +/- 3.8 years (4-17 years) and 30 +/- I I kg (13.5-55 kg), respectively. The patients have been followed for 7-84 months (median 42 months). The percentage of atrial sensing-ventricular pacing changed from 75 to 99.9% at the last control. During the follow-up period, pacing mode was changed to VVIR due to complete loss of AV synchrony in five patients (21%). Four of them had underlying cardiac disease. In these patients loss of AV synchrony might be related to cardiac enlargement/abnormal cardiac anatomy or small atrial dipole-ventricular tip length. Despite the loss of AV synchrony in post surgical AV block or dilated cardiomyopathy, single-lead VDD pacing systems can be successfully used in children with complete AV block and normal sinus node function. Patients and lead selection should be taken into consideration for the maintenance of AV synchrony.  相似文献   

5.
Sinus node disease and atrioventricular block are common etiologies of symptomatic bradyarrhythmias in the elderly and remain the leading indications for permanent pacemaker implantation. In fact, the vast majority (>80%) of all pacemakers are implanted in the elderly. Whereas indications of pacemaker therapy have been largely unchanged over the past several years, several questions, such as differences in pacemaker mode selection, remained unanswered. Recent large, randomized, multicenter trials have evaluated the benefits of pacemaker therapy in sinus node dysfunction and acquired atrioventricular block and have provided us with further insights into the difference between atrial- and ventricular-based pacing in these syndromes. Further evaluation of the most appropriate pacing mode in the elderly as well as the outcome of pacing in the elderly are addressed in this review.  相似文献   

6.
Single-chamber atrial pacing is effective in the management of sinus node dysfunction, subject to the uncertainty of long-term atrioventricular conduction. Despite the accepted observation that many patients with sinus node dysfunction also have atrioventricular conduction disease, data do not exist on the development of atrioventricular block in those patients with permanent single-chamber atrial pacing. Of 70 patients who received single-chamber atrial pacing from 1967 to 1982 (mean duration of pacing was 33 months), only two patients of 58 (3.4%) of those with sinus node dysfunction developed atrioventricular (AV) block—after 14 months in one patient and after 23 months of successful atrial pacing in the other. None of the 12 patients paced for tachyarrhythmia management developed AV block. Of the 70 patients, 37 had assessment of AV conduction by incremental atrial pacing at the time of implant and 20 patients underwent atrial pacing on the basis of surface ECG and clinical judgment. Electrophysiologic studies were conducted only in those patients being paced for control of supraventricular arrhythmias. Only 5 of the 70 patients required conversion to ventricular pacing for technical difficulties; three of these conversions occurred in the early 1970's before the advent of atrial tined or J leads; one was for irreparable lead fracture and only one occurred in a patient with a newer design atrial lead. In conclusion, progression to AV block in patients with permanent atrial pacing is uncommon; formal electrophysiologic studies are necessary mainly in patients with supraventricular arrhythmias; and in the majority of patients, AV conduction can be assessed at the time of implant. Continued improvement in atrial leads should make atrial pacing even more successful.  相似文献   

7.
We prospectively evaluated and followed-up 45 patients with syncope in whom conventional cardiovascular and neurological investigations did not reveal the cause. All patients underwent electrophysiologic studies to assess the function of the sinus node and the integrity of atrioventricular conduction. These included the ajmaline test and the inducibility of supraventricular or ventricular tachycardia. Seven patients (15.5%) had evidence of sinus node dysfunction, 8 patients (17.7%) had evidence of infra-His atrioventricular block after ajmaline administration and 5 patients (11.1%) had inducible ventricular tachycardia. The remaining 25 patients (55.5%) had non-diagnostic studies. All patients with sinus node dysfunction and inducible infra-His atrioventricular block were asymptomatic during a mean follow-up period of 14.3 +/- 9.5 months after implantation of a permanent pacemaker. Patients with inducible ventricular tachycardia (except 1 with poor left ventricular function who died) were likewise asymptomatic while receiving laboratory guided anti-arrhythmic drug therapy. Twenty-five patients with non-diagnostic studies who were treated empirically are alive but the symptoms persist in 14 (56%). Provocative electrophysiological studies are of diagnostic and therapeutic utility in a significant number of patients with recurrent syncope of "unknown cause".  相似文献   

8.
9.
10.
The authors analysed the prevalence of atrioventricular conduction defects and sinus node dysfunction by Holter monitoring in three population groups with similar clinical characteristics: 50 controls (Group I), 17 physically fit subjects with an atrioventricular conduction defect on the resting ECG which was usually asymptomatic (Group II), and 48 professional pilots who were also physically fit but who had no conduction defects on resting ECG (Group III). The 24 hour recordings showed: --a similar incidence of sinus dysrhythmias and atrioventricular conduction defects in the three groups although the frequency of low degree block was a little higher in sportsmen; --a preponderance of the association of first degree block and nocturnal Luciani-Wenckebach periods, sometimes with episodes of Mobitz II block; --the absence of progression to high-degree atrioventricular block. Holter monitoring would therefore seem to be a good method of detecting and following up abnormalities of sinus node function and atrioventricular conduction defects in asymptomatic patients. In addition, it gives a qualitative and quantitative assessment of the recorded changes and provides a means of monitoring their evolution.  相似文献   

11.
OBJECTIVE: To investigate the incidence of sinus node disease after pacemaker implantation for exclusive atrioventricular (AV) block. DESIGN: 441 patients were followed after VDD (n = 219) or DDD pacemaker (n = 222) implantation for AV block over a mean period of 37 months. Sinus node disease and atrial arrhythmias had been excluded by Holter monitoring and treadmill exercise preoperatively in 286 patients (group A). In 155 patients with complete AV block, a sinus rate above 70 beats/min was required for inclusion in the study (group B). Holter monitoring and treadmill exercise were performed two weeks, three months, and every six months after implantation. Sinus bradycardia below 40 beats/min, sinoatrial block, sinus arrest, or subnormal increase of heart rate during treadmill exercise were defined as sinus node dysfunction. RESULTS: Cumulative incidence of sinus node disease was 0.65% per year without differences between groups. Clinical indicators of sinus node dysfunction were sinus bradycardia below 40 beats/min in six patients (1.4%), intermittent sinoatrial block in two (0.5%), and chronotropic incompetence in five patients (1.1%). Only one of these patients (0.2%) was symptomatic. Cumulative incidence of atrial fibrillation was 2.0% per year, independent of the method used for the assessment of sinus node function and of the implanted device. CONCLUSIONS: In patients undergoing pacemaker implantation for isolated AV block, sinus node syndrome rarely occurs during follow up. Thus single lead VDD pacing can safely be performed in these patients.  相似文献   

12.
A patient with sinus bradycardia and atrioventricular block, induced by carbamazepine, prompted an extensive literature review of all previously reported cases. From the analysis of these cases, two distinct forms of carbamazepine-associated cardiac dysfunction emerged. One patient group developed sinus tachycardias in the setting of a massive carbamazepine overdose. The second group consisted almost exclusively of elderly women who developed potentially life-threatening bradyarrhythmias or atrioventricular conduction delay, associated with either therapeutic or modestly elevated carbamazepine serum levels. Because carbamazepine is widely used in the treatment of many neurologic and psychiatric conditions, the recognition of the latter syndrome has important implications for the use of this drug in elderly patients.  相似文献   

13.
Twenty-three children underwent electrophysiological studies during routine postoperative catheterization two months to five years after complete correction of tetralogy of Fallot. The aim of the study was to investigate the whole conduction system, including sinus node function, suing His bundle recordings and atrial pacing. H-V intervals were normal at rest and with pacing in twenty-two patients, including four patients with evidence of bifascicular block on the surface ECG. One patient with cardiomegaly and evidence of diffuse myocardial damage had a prolonged H-V interval but did not develop a block at this level during pacing A-H interval was slightly prolonged in four patients and normal in all others. The threshold of pacing-induced atrioventricular block ranged from 75 to 240/min and was somewhat age dependent (r = -0.55). Two patients fell below the 95% confidence limit of this regression and are considered abnormal. One returned to normal after intravenous injectionof atropine. Corrected sinus node recovery time ranged from 60 to 2000 msec. Three patients had values above 500 msec which are considered abnormal. These patients had other minor signs of sinus node dysfunction, i.e., episodes of sino-atrial block at rest or intermittent sinus bradycardia. Thus, while the His Purkinje system performed satisfactorily in all patients, sinus node dysfunctional and A-V node dysfunction were demonstrated in a few patients after correction of tetralogy of Fallot.  相似文献   

14.
病态窦房结综合征患者房室传导功能分析   总被引:3,自引:0,他引:3  
杨芳  李莉 《心电学杂志》1999,18(2):83-84
为了解病态窦房结综合征患者的房室传导功能,用食管电生理检查观察窦房结功能正常者86例、窦房结功能低下者40例和病态窦房结综合征者109例的房室传导功能.结果显示:3组的文氏型阻滞点、2:1阻滞点差异无显著意义(P>0.05).将窦房结功能障碍者的窦房结恢复时间与文氏型阻滞点、2:1阻滞点作相关分析,结果均无相关性(P>0.05).认为病态窦房结综合征发生房室传导阻滞的概率较低,植入起搏器前应作食管心房调搏检查房室传导系统功能.  相似文献   

15.
AIMS: An inherent limitation of single lead VDD pacing is the inability to stimulate the atria. Reprogramming and upgrading the pacemaker system may be required when sinus node dysfunction, atrial undersensing, or atrial fibrillation develop. We evaluated whether routine clinical information is sufficient to select patients to benefit in long-term from VDD pacing. METHODS AND RESULTS: We collected data on 12-lead and monitored electrocardiograms and routine clinical information at implantation of a VDD pacing system in 350 consecutive patients with grade II or III atrioventricular conduction block. The age at implantation was 74.5 +/- 8.0 years, and the follow-up lasted 1.5 +/- 1.5 years. The cumulative maintenance of VDD pacing mode was 91.%. Loss of VDD mode was due to permanent atrial fibrillation in 16 (4.6%), sinus node dysfunction in six (1.7%). atrial undersensing in 11 (3.1%). Chronic atrial fibrillation developed in 23% of patients who had heart enlargement in chest x-ray and a history of paroxysmal atrial fibrillation or flutter. A criterion of normal sinus rate at implantation sufficiently predicted adequate sinus node function. Poor atrial sensing was not predicted by pre-implant characteristics. CONCLUSIONS: According to our data, adequate sinus-driven atrial rate and no history of paroxysmal atrial fibrillation and cardiac enlargement predict maintenance of the VDD pacing mode in elderly patients treated for heart block. Routine information available at implantation is sufficient to guide acceptance of single lead VDD pacing therapy.  相似文献   

16.
BackgroundArrhythmia is not uncommon among pulmonary hypertension (PH) population, and may be associated with disease severity.HypothesisTo investigate different spectrums and prevalence of arrhythmias in different clinical PH groups in Chinese population.MethodsPatients diagnosed with PH between April 15, 2019, and August 2, 2021, were enrolled prospectively. The prevalence of different types of arrhythmias in PH patients were calculated. Logistic regression analyses were conducted to determine independent predictors for arrhythmia.ResultsOne thousand patients were enrolled. The prevalence of any arrhythmia, sinus node dysfunction, sinus tachycardia, atrial fibrillation, atrial flutter, other types of atrial tachycardia, atrioventricular block, and ventricular tachycardia is 44.4%, 12.2%, 15.2%, 8.1%, 4.1%, 10.2%, 7.1%, and 2.5%. Logistic regression analyses revealed that older age and larger right ventricle (odds ratio: 1.111 and 1.095, p < .05) were independently related with higher probability of supraventricular arrhythmia; Complicating with coronary artery disease, larger right ventricle, and increased left ventricular end‐diastolic diameter (odds ratio: 19.540, 1.106, and 1.085, p < .05) were independently correlated with sinus node dysfunction/atrioventricular block in patients with pulmonary arterial hypertension.ConclusionsNearly half of PH patients experienced at least one type of arrhythmia. The most common seen arrhythmias were supraventricular arrhythmia, sinus tachycardia, and sinus node dysfunction. Older age and larger right ventricle were independently related with higher probability of supraventricular arrhythmia; Complicating with coronary artery disease, larger right ventricle and increased left ventricular end‐diastolic diameter were independently correlated with higher probability of sinus node dysfunction/atrioventricular block in patients with pulmonary arterial hypertension.  相似文献   

17.
S R Spielman 《Geriatrics》1985,40(6):65-8, 71
AV sequential pacemakers are particularly useful in patients who have developed "pacemaker syndrome" with single-chambered ventricular demand units, since the normal atrioventricular relationship is then restored. Fully automatic pacemakers are indicated for patients with AV block, with or without sinus node dysfunction, or with moderate sick sinus syndrome and AV nodal or His-Purkinje disease, with at least some ability to increase atrial rate with exercise.  相似文献   

18.
Ninety symptomatic patients aged between 16 and 90 years were investigated by ambulatory continuous 24 hour electrocardiography. 75 of these patients underwent endocavitary exploration of atrioventricular conduction and sinus node function within 48 hour of ambulatory electrocardiography. Symptoms occurred during the recording in 30% patients, enabling the mechanism of the malaise to be determined. Every time that abnormalities in the zone surrounding the Tawara node were demonstrated by endocavitary recordings, the 24 hour electrocardiogramme showed the symptoms to be due to other causes than complete heart block. In 70% patients no symptoms were experienced but 58% of them had cardiac arrhythmias and particularly sinus node dysfunction (24 out of 37 patients) on the 24 hour electrocardiogramme. Comparing the results of these two methods of investigation, continuous electrocardiography appears to be a better technique for the diagnosis of sinus node dysfunction but endocavitary study of sinus node function would seem more suited to determine its severity. Endocavitary recordings seem more reliable in the investigation of paroxysmal atrioventricular blocks. These results demonstrate the complementary nature of these two methods in determining the causes of syncope and dizziness.  相似文献   

19.
Results of recent trials suggest that in patients with left ventricular dysfunction, interventricular synchrony is possibly more important than atrioventricular synchrony. In patients with AV block and conduction system disease, alternatives to right ventricular apical pacing are therefore needed.  相似文献   

20.
Guanabenz acetate is an antihypertensive drug that is closely related to clonidine hydrochloride. Clonidine is well known to potentiate atrioventricular (AV) node conduction disturbances, but to date that effect has not been attributed to guanabenz. A case of electrocardiographic and electrophysiologic studies in a patient with both sinus and AV node conduction disturbances associated with the use of guanabenz acetate is reported. The sinus cycle length was increased by 50% after guanabenz and the sinus node recovery time was prolonged by 42%. AV block occurred proximal to the His bundle and His-ventricular prolongation of 42% also occurred. This drug should be used cautiously in patients with evidence of sinus or AV node dysfunction.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号