首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
BACKGROUND: The use of safe iodinated contrast media (CM) to prevent contrast-induced nephropathy (CIN) is an important consideration among renally impaired diabetic patients during coronary angiography. HYPOTHESIS: Diabetic patients with normal or mild renal dysfunction are less likely to receive renal protective measures during angiography, yet they may also be at risk for CIN. We compared the renal effects of iopamidol and iodixanol in diabetic patients who were referred for angiography. METHODS: Diabetic patients (N=122) with a serum creatinine (SCr) level of < or = 2 mg/dl were double-blind randomized to receive nonionic CM: iopamidol-370 (low osmolar, monomeric) or iodixanol-320 (iso-osmolar, dimeric). Renal stability was evaluated at baseline and at Days 1, 3, and 7 post-angiography. The primary endpoint was a > or = 25% increase in SCr. RESULTS: Seventeen (10 iopamidol, 7 iodixanol; P=NS) patients had an increase in SCr > or = 25% over baseline. Over all days, analysis revealed nonsignificant differences in the incidence of CIN between the two study groups regardless of how CIN was defined. CONCLUSIONS: Diabetic patients with normal or mild renal dysfunction are at risk for CIN. No significant difference in renal response was observed for these CM in this at-risk population.  相似文献   

2.
The aim of this study was to assess the impact of two nonionic low-osmolar monomers (iopamidol and iopromide) and one ionic low-osmolar dimeric contrast medium (ioxaglate) on 30-day major adverse cardiac events in patients undergoing coronary interventions involving the use of new-generation stents and appropriate antiplatelet agents. Thirteen hundred and eight patients treated with stent implantation were randomized to receive ioxaglate (438 patients), iopamidol (442 patients), or iopromide (428 patients). Most of them (55%) had an acute coronary syndrome. Glycoprotein IIb/IIIa inhibitors were used in 37% of cases. All of the patients were on aspirin and ticlopidine for 1 month after the procedure. There was no significant between-group difference in the incidence of the primary composite endpoint of major adverse cardiac events 30 days after stenting (ioxaglate 3.6%; iopamidol 2.3%; iopromide 4.2%; P = 0.27). Adverse drug reactions were more frequent in the ioxaglate group (4.6% vs. 1.1% vs. 0.5%; P = 0.001). Multivariate analysis showed that intracoronary thrombus (P = 0.002), diabetes mellitus (P = 0.01), and postprocedure minimum lumen diameter (P = 0.04) independently correlated with an adverse outcome after 1 month. In conclusion, no significant differences in 30-day major ischemic complications were observed in this unselected population of patients undergoing coronary stenting who received ioxaglate, iopamidol, or iopromide. These data seem to suggest that the use of nonionic low-osmolar contrast media does not adversely affect stent patency.  相似文献   

3.
目的观察非离子造影剂对老年冠状动脉(冠脉)造影患者肾功能的影响。方法选择具有冠脉造影适应证并行冠状动脉介入诊断、经皮冠脉介入治疗(PCI)的老年患者41例,年龄60~84(66±6)岁。于冠脉造影前、后第2天、第5天分别检查各项肾功能指标。以造影后2天内血清肌酐(Cr)比造影前增加44μmol/L或增加25%,或内生肌酐清除率(CCr)比造影前下降25%为诊断造影剂肾病的标准。结果PCI术后第2天血清尿素氮(BUN)、Cr、尿微量白蛋白浓度(UMALB)及24 h微量白蛋白总量(24 h UMALB)升高,24 h尿肌酐(UCr)、CCr较术前下降(P<0.05)。术后第5天上述指标与术前比较差异无显著性(P>0.05)。自由水清除率(free water clearance,CH2O)冠脉造影后第2天较术前升高(P<0.05),术后第5天未能恢复到术前水平(P<0.05)。按照造影剂肾病的诊断标准,共有8例患者可诊断造影剂肾病。结论非离子造影剂对行冠脉造影术的老年患者肾功能有一定损害,但多数属可逆性。  相似文献   

4.
Some patients cannot undergo coronary angiography (CAG) because of the adverse effects of contrast media. In the present study gadolinium, (gadodiamide hydrate: Gd DTPA-BMA) commonly used for magnetic resonance imaging (MRI), was used as the contrast agent for diagnostic CAG in 3 patients with severe allergy to iodine or iodinated contrast agents. The indications for CAG were recurrent chest pain, evaluation of peri-operative risk of gastric cancer and abdominal aortic aneurysm, and evaluation of graft patency after coronary artery bypass grafting. The procedure was well tolerated by each patient and the amount of the gadolinium-based contrast media did not exceed 40 ml, which is twice the volume used for MRI. The images were of fair quality. In patients with allergy to iodinated contrast media, CAG with gadolinium-based contrast media is an alternative technique for evaluating coronary artery disease.  相似文献   

5.
BACKGROUND: In coronary angiography, the use of contrast agents containing iodine still defines the gold standard. In patients with contraindications for iodine exposition, gadolinium has been considered to be a safe alternative to standard iodinated contrast medium for coronary angiography. The aim of the present study was to assess the safety and technical quality of gadolinium-based coronary angiography. METHODS: Nineteen consecutive patients with contraindication to iodinated contrast medium underwent gadolinium-based coronary angiography. Contraindications included previous anaphylactic shock or severe allergic reaction to iodinated contrast medium (n = 13) or thyrotoxicosis (n = 6). Gadolinium was diluted 1:1 with sodium chloride before application. Patients were clinically observed for potential side effects, and renal function was assessed by determination of creatinine values and calculation of creatinine clearance in pre- and postprocedural blood samples. Image quality was evaluated by two independent observers, and classified into three different categories (grade 1, high diagnostic quality; grade 2, moderate diagnostic quality; and grade 3, poor quality). RESULTS: During angiography, a mean of 32.6 +/- 10.9 mL (range 10-45 mL) gadolinium was used. No patient developed a significant impairment of renal function within 24 hours after the examination (mean creatinine value preprocedural: 1.12 +/- 0.15 mg/dL, postprocedural: 6 hours 1.15 +/- 0.18 mg/dL, 24 hours 1.13 +/- 0.16 mg/dL) (baseline vs. 6 hours P = 0.23, baseline vs. 24 hours P = 0.66, 6 hours vs. 24 hours P = 0.12) (mean creatinine clearance preprocedural: 73.8 +/- 18 mg/dL, postprocedural: 6 hours 71.7 +/- 16.8 mg/dL, 24 hours 73.2 +/- 17.8 mg/dL) (baseline vs. 6 hours P = 0.2, baseline vs. 24 hours P = 0.71, 6 hours vs. 24 hours P = 0.21). Four patients (21%) suffered severe complications due to gadolinium application, such as malignant cardiac arrhythmias (n = 3) and hemodynamic decompensation (n = 1). Image quality was generally reduced in comparison to iodine contrast coronary angiography, but was adequate for diagnostic purposes (13 patients [68.4%] had reasonably good picture contrast [grade 2.1 +/- 0.3]; in 6 patients [31.6%], image quality was satisfactory [grade 2.6 +/- 0.13]). Opacification of distal vessels as compared to proximal segments was remarkably reduced. CONCLUSIONS: Gadolinium-based coronary angiography is a potential alternative technique in patients with allergy to iodinated contrast medium or thyrotoxicosis with reduced, but acceptable, image quality for diagnostic purposes. Nevertheless, possible life-threatening side effects and complications have to be considered.  相似文献   

6.
Yip HK  Hang CL  Fang CY  Hsieh YK  Yang CH  Hung WC  Wu CJ 《Chest》2005,127(3):803-808
BACKGROUND: C-reactive protein (CRP) has been well recognized as a strong independent predictor of short-term and long-term mortality after non-ST-segment elevation acute coronary syndromes. However, limited studies have been conducted correlating CRP levels within 6 h following the onset of ST-segment elevation (ST-se) acute myocardial infarction (AMI) to mortality. The purpose of this study was to evaluate the predictive value of CRP measured by high-sensitivity CRP assay (hsCRP) on 30-day clinical outcomes in patients with ST-se AMI of onset < 6 h undergoing primary percutaneous coronary intervention (PCI). METHODS AND RESULTS: We conducted a prospective cohort study in 146 consecutive patients with ST-se AMI of onset < 6 h who were undergoing primary PCI. Blood samples for hsCRP were obtained in the catheterization laboratory before coronary angiography. Patients were classified into high (group 1: hsCRP > 2.37 mg/L, n = 73) and low (group 2: hsCRP 相似文献   

7.
8.
9.
10.
Contrast-induced nephropathy (CIN) is a common cause of hospital-acquired renal failure. Gadolinium-based contrast agents have been proposed as alternatives to iodinated contrast in patients at high risk for CIN. The use of high-dose intraarterial gadolinium chelates in the catheterization laboratory has been investigated in only a small number of patients. We compared patients with a creatinine clearance <60 ml/min/1.73 m2 who received intravenous hydration (> or =1,500 ml) and oral n-acetylcysteine prophylaxis with those who received a gadodiamide-iodine mixture (n = 90) or iodinated contrast alone (n = 79) in the cardiac catheterization laboratory. CIN was defined as an increase of 0.5 mg/dl in serum creatine from baseline. The 2 groups were similar with respect to demographics and risk factors. Although less iodinated contrast was used in the gadolinium mixture group, there was no difference in the incidence of CIN between the 2 groups. However, the initiation of dialysis (n = 7) and death (n = 8) only occurred in the diluted gadolinium contrast group. A stepdown multivariate analysis found diabetes mellitus to be the only independent predictor of CIN (p = 0.02, odds ratio 3.35, 95% confidence interval 1.21 to 9.29, c-statistic 0.66). In conclusion, the incidence of CIN was not decreased in high-risk patients receiving a gadolinium-iodinated contrast mixture versus iodinated contrast alone.  相似文献   

11.

Background

Contrast-induced nephropathy (CIN) is the acute deterioration of renal function after parenteral administration of radio contrast media in the absence of other causes. The true incidence of CIN varies because of differences among the published studies in the definition of CIN, the proportion of high-risk patients, the types of contrast media, and the use of preventive measures. Remote ischemic preconditioning (IPC) may offer a non-pharmacological prevention strategy for lowering CIN in patients undergoing coronary procedures. The assumption that IPC produces protective effects on tissues or organs by multiple brief cycles of ischemia and reperfusion applied to another remote tissue or organ.

Aim

To investigate the effect of ischemic preconditioning in prevention of CIN in patients with renal impairment undergoing percutaneous coronary angiography.

Results

In this study, 100 patients undergoing elective PCI with a base line creatinine clearance <60?ml/min were studied. Patients were divided into two equal groups (ischemic preconditioning group and control group). The incidence of CIN was markedly lower in ischemic preconditioning group 14% VS 38% in control group. The incidence of CIN difference as was found to be (24%). Amount of dye used, decreased LVEF and presence of a significant LAD lesion were significant risk factors for occurrence of CIN.

Conclusions

The current study showed that remote ischemic preconditioning plays an important role in prevention of CIN in patients undergoing PCI with renal impairment GFR?<?60?ml/min. The amount of contrast, decreased LVEF, and presence of LAD significant lesion were significant risk factors for developing of CIN and these subgroups benefited from application of ischemic preconditioning.  相似文献   

12.
13.
14.
CONTEXT: The adipokine adiponectin has been suggested to protect against coronary artery disease (CAD). However, studies addressing the association between adiponectin and mortality are sparse. OBJECTIVE: The objective of the study was to elucidate the relationship between adiponectin and mortality. DESIGN, SETTING, AND PARTICIPANTS: Adiponectin was determined in 2473 persons with and 673 persons without angiographic CAD. During a mean follow-up period of 5.45 yr, 427 persons with CAD and 55 persons without CAD died. MAIN OUTCOME MEASURE: Hazard ratios for mortality according to adiponectin levels were measured. RESULTS: Adiponectin was positively related to female gender, age, low-density lipoprotein cholesterol, high-density lipoprotein cholesterol, homocysteine, and N-terminal pro-B-type natriuretic peptide. It was inversely related to glomerular filtration rate, body mass index, and triglycerides and was low in diabetes mellitus and CAD. An increase of 1 sd in adiponectin was associated with unadjusted and fully adjusted hazard ratios for death from any cause of 1.31 [95% confidence interval (CI) 1.20-1.42] and 1.22 (95% CI 1.12-1.34), and for death from cardiovascular causes of 1.32 (95% CI 1.19-1.45) and 1.23 (95% CI 1.11-1.37), respectively. In angiographic CAD, stable CAD, and unstable CAD, the predictive value of adiponectin was similar to that in the entire cohort, but it did not attain statistical significance in persons without angiographic CAD. Adiponectin was also positively related to the risk of death from noncardiovascular causes. CONCLUSIONS: Despite the common view about adiponectin as a protective molecule in cardiovascular disease, high adiponectin independently predicts all-cause, cardiovascular, and noncardiovascular mortality in individuals with CAD.  相似文献   

15.
目的:探讨拟行冠状动脉造影和(或)介入治疗患者,采用低渗对比剂与等渗对比剂对其肾功能的影响。方法:本研究为单中心、随机、单盲及前瞻性研究,选择2012年11月至2013年10月,于安贞医院接受冠状动脉造影和(或)介入治疗患者共302例,按数字表法随机分为甲、乙两组,其中甲组使用低渗对比剂共180例,乙组使用等渗对比剂共122例,甲组中肾功能正常者130例,肾功能减低者50例,乙组中肾功能正常者91例,肾功能减低者31例,总体比较两组患者对比剂肾病(contrast induced nephropathy,CIN)的发病率,及分别比较两组中肾功能正常及肾功能减低其CIN的发病率。结果:①在总体例群中,低渗组中CIN 11例(6.11%),等渗组中CIN 7例(5.74%),低渗组术后血肌酐值(serum creatinine,SCr)为(76.91±16.80)μmol/L,等渗组患者术后SCr为(78.68±22.98)μmol/L,均差异无统计学意义(P0.05)。②对于肾功能正常的亚组,术后SCr及CIN发病率差异无统计学意义。③对于肾功能减低的亚组,两组术后SCr差异无统计学意义。低渗组CIN患者7例(14%),等渗组CIN患者3例(9.7%),等渗组发病率显著低于低渗组。结论:在总体例群中,无论在术后SCr值,还是CIN的发病率,应用等渗对比剂与低渗对比剂差异无统计学意义。在肾功能减低的患者中,应用等渗对比剂其CIN的发病率明显少于低渗对比剂。  相似文献   

16.
Periodontal inflammation has been implicated in atherosclerosis and coronary heart disease (CHD). Coronary angiography (CA) is used in the assessment of CHD; only a few studies have evaluated periodontal disease (PD) and angiographic measures of coronary atherosclerosis. The aim of this study was to investigate the association between CHD and PD. In this prospective epidemiologic study, 466 patients underwent CA and were assessed for PD. All patients underwent physical, laboratory, cardiac, and dental examination including dental x-rays. Periodontal disease and coronary angiograms were evaluated blindly by a dentist and 2 cardiologists, respectively. A coronary stenosis greater than 50% was ruled as CHD. Periodontal disease was defined and measured with the Community Periodontal Index of Treatment Needs (CPITN); and if at least 2 sextants (segments dividing mandible and maxilla into 6) were recorded as having CPITN of at least 3 (signifying that sextant had periodontal pocket depth ≥3.5 mm), the patient was coded as having PD. Three-hundred forty-nine patients (74.9%) had CHD assessed by CA The CHD patients had PD in 55.6% vs 41.9% in the non-CHD patients (P < .01). The CPITN scores were significantly higher in patients with vs without CHD, 2.43 vs 2.16, respectively (P = .023). After adjusting for age, sex, and risk factors for atherosclerosis with additional inclusion of C-reactive protein and erythrocyte sedimentation rate, PD remained significantly related to CHD (odds ratio = 1.9; 95% confidence interval, 1.2-3.1). Other predictors for CHD were male sex, age, high-density lipoprotein cholesterol, and diabetes. Our results demonstrate an increased odds ratio for angiographically determined CHD in patients with PD and that CHD and PD may cluster in particular groups of a population. Our data indicate that PD represents a potentially modifiable risk factor that is both preventable and treatable with predictable treatments that pose negligible risk.  相似文献   

17.
The purpose of this study was to compare the differential effects of ionic, high-osmolar meglumine diatrizoate; ionic, low-osmolar ioxaglate meglumine; and nonionic, low-osmolar iohexol (all radiographic contrast agents) on coronary blood flow velocity and hyperemic responses during diagnostic coronary angiography. Coronary flow velocity and arterial pressure were measured at baseline and during maximal hyperemia after contrast media were randomly injected (4 to 6 ml into left coronary artery) in 22 patients with the use of a Judkins-style 20 MHz Doppler-tipped angiographic catheter. Contrast media-induced hyperemic responses were compared to those induced with intracoronary nitroglycerin (200 micrograms) and papaverine (10 mg). There were no significant differences in systolic, diastolic, or mean arterial pressure measurements among the three contrast agents. The increase in mean coronary flow velocity during hyperemia was 118 +/- 93%, 133 +/- 73%, and 136 +/- 86% for iohexol, ioxaglate meglumine, and diatrizoate, respectively (p = NS among agents vs 264 +/- 109% for papaverine; p less than 0.05 for all). Coronary vasodilatory reserve (calculated as the ratio of hyperemic to basal mean flow velocity) was also similar among agents. It was comparable to the coronary vasodilatory reserve with nitroglycerin (2.1 +/- 1.0 to 2.2 +/- 1.1) and significantly less than that with papaverine (3.3 +/- 2.2, p less than 0.05). These data indicate that the clinical advantages of nonionic or low-osmolar contrast media are not mechanistically related to significant attenuation of the coronary hyperemic response.  相似文献   

18.
The use of nonionic contrast agents during cardiac catheterization decreases the incidence of both major and minor cardiovascular complications when compared with ionic contrast. Hemodynamic and electrophysiologic effects are less profound especially in patients who have severe coronary artery disease or left ventricular dysfunction. Sparse data exist comparing ionic and nonionic contrast in patients undergoing percutaneous transluminal coronary angioplasty. No clinical evidence suggests that nonionic contrast agents are less nephrotoxic than ionic contrast though patients with significant baseline renal dysfunction (creatinine > 3.0) might benefit. The incidence of thrombotic events appears to be similar for both types of agents. Finally, the risk reduction of cardiovascular events must be weighed against markedly higher costs.  相似文献   

19.
20.
Ventricular fibrillation during coronary angiography with Renografin-76 has been attributed to the high osmolar ionic and calcium binding additive properties. Isovue-370 is a new low osmolar nonionic contrast medium lacking calcium binding additives. The present investigation compared the incidence of contrast media-induced ventricular fibrillation in patients undergoing coronary angiography with Renografin-76 to that with Isovue-370. Group I consisted of 2,000 consecutive patients undergoing coronary angiography with Renografin-76, and group II consisted of 2,000 subsequent consecutive patients in whom Isovue-370 was employed as the contrast medium. There was no significant difference between groups I and II with respect to volume of contrast media used per patient (125 +/- 35 vs. 140 +/- 45 ml), age (63.5 +/- 15 vs. 60 +/- 17 years), sex (74% male vs. 76% male), ejection fraction (55% vs. 55%), valvular heart disease (8% vs. 9%), prior coronary artery bypass graft surgery (5.8% vs. 5%), or extent of coronary artery disease. Contrast media-induced ventricular fibrillation occurred in 20 patients in group I (incidence 1%), whereas eight episodes occurred in group II (incidence 0.4%) (P less than 0.03). Thus the present investigation suggests that the incidence of ventricular fibrillation during coronary angiography can be significantly decreased by using low osmolar nonionic contrast media lacking calcium binding additives.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号