首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到17条相似文献,搜索用时 62 毫秒
1.
齐颖  周跃华  张晶 《眼科》2011,20(2):121-125
目的 比较飞秒激光制瓣和角膜板层刀制瓣LASIK手术的临床效果.设计 回顾性病例系列.研究对象 北京同仁医院88例(172眼)应用Intralase FS60飞秒激光制瓣后行LASIK手术患者和122例(242眼)M2角膜板层刀制瓣LASIK手术患者.方法 将飞秒激光制瓣LASIK手术的患者(I-LASIK)为I组;角...  相似文献   

2.
目的:基于角膜基质床厚度/术前角膜厚度(residual corneal stroma thickness /corneal thickness,RCST/CT)的不同,比较飞秒激光辅助LASIK和角膜板层刀辅助LASIK术后早期角膜生物力学的变化。

方法:选取190例379眼,其中飞秒激光辅助LASIK组94例187眼,角膜板层刀辅助LASIK组96例192眼。根据术后剩余RCST/CT的不同,将飞秒激光辅助LASIK组(FS-IK组)和角膜板层刀辅助LASIK组(M-IK组)各分为三组,IK-Ⅰ组(RCST/CT<55%)、IK-Ⅱ组(55%≤RCST/CT<60%)和IK-Ⅲ组(RCST/CT≥60%)。分别于术前、术后1mo和3mo应用眼反应分析仪(reichert ocular response analyzer,ORA)检测角膜滞后量(corneal hysteresis,CH)和角膜阻力因子(corneal resistance factor,CRF)。

结果:不同手术方式(FS-IK与M-IK)比较,CH和CRF均无统计学差异(F=0.44,F=2.56,P=0.51,P=0.11)。不同的RCST/CT比较,CH和CRF均有统计学差异(F=103.03,128.48,P均<0.05)。Ⅰ组CH和CRF较Ⅱ组明显减小(P<0.05),Ⅱ组CH和CRF较Ⅲ组明显减小(P<0.05),Ⅰ组CH和CRF较Ⅲ组明显减小(P<0.05)。术前及术后不同时间比较,CH和CRF均有统计学差异(F=576.99, 1162.06,P均<0.05)。术后1mo和3mo,CH和CRF均较术前明显减小(P<0.05),术后1mo和术后3mo比较,CH和CRF差异无统计学意义(P>0.05)。

结论:无论是飞秒激光辅助LASIK还是角膜板层刀辅助LASIK在术后早期角膜生物力学参数均下降,但两种手术方式对角膜生物力学的影响无差异。LASIK术后保留角膜基质床比例越小对角膜生物力学的影响越大。  相似文献   


3.
目的:观察飞秒激光和角膜板层刀制瓣LASIK术后泪膜的变化。

方法:回顾性分析150例300眼近视患者,根据制作角膜瓣方法不同分为两组,组1为飞秒激光(Intralase FS60KHz)制作角膜瓣,95例190眼; 组2为Moria M2 90号板层刀制瓣,55例110眼。观察两组术前、术后1wk; 1,3,6mo患者的干眼症状评分、泪膜破裂时间(tear break-up time,BUT)、泪液分泌试验(Schirmer I test,S I t)、角膜荧光素染色(corneal fluorescence staining,FL)评分的变化。

结果:干眼症状评分:两组术后1wk; 1,3mo差异有统计学意义(P<0.05),术后6mo差异无统计学意义(P>0.05)。BUT:两组术后1wk; 1,3mo差异有统计学意义(P<0.05),术后6mo差异无统计学意义(P>0.05)。SchirmerⅠ试验:两组术后1wk; 1,3mo差异有统计学意义(P<0.05),术后6mo差异无统计学意义(P>0.05)。荧光素染色评分:两组术后1wk; 1,3mo差异有统计学意义(P<0.05),术后6mo差异无统计学意义(P>0.05)。

结论:飞秒激光和角膜板层刀制瓣LASIK术后早期泪膜功能减退,但飞秒激光制瓣术后泪膜功能恢复更快。  相似文献   


4.
目的 比较应用飞秒激光和角膜板层刀制瓣准分子激光原位角膜磨镶术(LASIK)的临床效果.方法 回顾性分析400例(800眼)近视手术,根据制作角膜瓣方法不同分为两组,每组均为200例(400眼),组1为飞秒激光(Intralase FS60 kHz)制作角膜瓣,组2为Moria M2 90号板层刀制瓣.两组均在Wavescan波前引导下VISX Star S4准分子激光进行基质层切削.术后3个月、6个月行视力、屈光状态、波前像差等检查.结果 术后3个月、6个月两组视力和屈光度比较差异无统计学意义(P>0.05).术后3个月,组2总高阶像差、彗差、球差高于组1,两组差异有统计学意义(P<0.05),三叶草像差比较差异无统计学意义(P>0.05).术后6个月,组2总高阶像差、彗差、球差、三叶草像差均高于组1,两组差异有统计学意义(P <0.05).结论 应用飞秒激光和角膜板层刀制瓣LASIK术是矫正近视安全有效的方法,在提高视觉质量和安全性方面飞秒激光优于角膜板层刀制瓣LASIK术.  相似文献   

5.
背景 准分子激光角膜原位磨镶术(LASIK)是目前矫正近视和近视散光的主要手术方式之一,研究表明飞秒激光制瓣LASIK的安全性、精确性及可预测性明显优于微型角膜刀制瓣LASIK,但飞秒激光制瓣LASIK对患者视觉质量的影响仍是关注的焦点. 目的 比较Intralase FS60飞秒激光和Moria M2微型角膜刀制瓣LASIK矫正屈光不正的临床疗效及术后视觉质量. 方法 采用前瞻性非随机临床对照研究方法,纳入2012年3-8月于首都医科大学附属北京同仁医院拟行LASIK治疗近视及近视散光并符合纳入标准的患者共102例204眼.根据自愿的原则将患者分为2个组,各组患者基线特征匹配.飞秒激光制瓣组50例100眼行飞秒激光制瓣的LASIK,微型角膜刀制瓣组52例104眼行微型角膜刀制瓣的LASIK.分别于术前及术后3个月、6个月和1年采用波前像差仪分析6 mm瞳孔下Zernike系数及高阶像差的均方根值,采用Optec 6500视功能测试仪测定暗视及暗视+眩光状态下1.5、3.0、6.0、12.0和18.0 c/d空间频率的对比敏感度(CS).结果 飞秒激光制瓣组术后3个月、6个月和1年裸眼视力达到及超过术前最佳矫正视力(BCVA)者分别占95.1%、94.2%和93.9%,微型角膜刀制瓣组分别为94.2%、93.8%和93.2%.术前、术后3个月和术后1年,飞秒激光制瓣组等效球镜度(SE)分别为(-6.37±2.12)、(-0.26±0.45)和(-0.45±0.51)D,微型角膜刀制瓣组分别为(-6.25±2.05)、(-0.44±0.64)和(-0.35±0.59)D,术后3个月和1年2个组间SE比较差异均无统计学意义(u=l.194、1.429,均P>0.05).术后3个月、6个月及1年飞秒激光制瓣组总高阶像差(RMSh)及各项高阶像差均明显低于微型角膜刀制瓣组(均P<0.05).术后3个月和6个月飞秒激光制瓣组术眼在暗视及暗视+眩光状态下各空间频率的LogCS值均明显优于微型角膜刀制瓣组,差异均有统计学意义(均P<0.05).术后1年,2个组间术眼在暗视状态下1.5 c/d空间频率的LogCS差异无统计学意义(P>0.05),而飞秒激光制瓣组术眼在暗视及暗视+眩光状态下12.0 c/d和18.0 c/d空间频率的LogCS值均明显优于微型角膜刀制瓣组,差异均有统计学意义(均P<0.05). 结论 飞秒激光制瓣的LASIK术后产生的高阶像差低于微型角膜刀制瓣的LASIK,视觉质量优于微型角膜刀制瓣的LASIK.  相似文献   

6.
目的:基于角膜基质床厚度/术前角膜厚度( residual corneal stroma thickness /corneal thickness,RCST/CT)的不同,比较飞秒激光辅助LASIK和角膜板层刀辅助LASIK术后早期角膜生物力学的变化。
  方法:选取190例379眼,其中飞秒激光辅助LASIK组94例187眼,角膜板层刀辅助LASIK组96例192眼。根据术后剩余RCST/CT 的不同,将飞秒激光辅助LASIK 组( FS-IK组)和角膜板层刀辅助LASIK组( M-IK组)各分为三组, IK-Ⅰ组( RCST/CT<55%)、IK-Ⅱ组(55%≤RCST/CT<60%)和IK-Ⅲ组( RCST/CT≥60%)。分别于术前、术后1mo和3mo应用眼反应分析仪( reichert ocular response analyzer,ORA)检测角膜滞后量( corneal hysteresis, CH)和角膜阻力因子(corneal resistance factor,CRF)。
  结果:不同手术方式( FS-IK与M-IK)比较,CH和CRF均无统计学差异(F=0.44,F=2.56,P=0.51,P=0.11)。不同的RCST/CT 比较, CH 和 CRF 均有统计学差异( F=103.03,128.48,P均<0.05)。Ⅰ组CH和CRF较Ⅱ组明显减小(P<0.05),Ⅱ组CH和CRF较Ⅲ组明显减小(P<0.05),Ⅰ组CH和CRF较Ⅲ组明显减小(P<0.05)。术前及术后不同时间比较, CH和CRF均有统计学差异( F=576.99,1162.06,P均<0.05)。术后1mo和3mo,CH和CRF均较术前明显减小( P<0.05),术后1 mo和术后3 mo比较,CH和CRF差异无统计学意义( P>0.05)。
  结论:无论是飞秒激光辅助LASIK还是角膜板层刀辅助LASIK在术后早期角膜生物力学参数均下降,但两种手术方式对角膜生物力学的影响无差异。 LASIK术后保留角膜基质床比例越小对角膜生物力学的影响越大。  相似文献   

7.
角膜瓣的制作是准分子激光原位角膜磨镶术的关键步骤之一.飞秒激光制作角膜瓣的方式与传统的机械刀制瓣相比,其术后视觉质量究竟有无优势,以及不同制瓣方式对视觉质量的影响因素有哪些仍是目前大家非常关注的话题,本文就此方面目前的研究进展作一综述.  相似文献   

8.
刘娟  胡恩海 《国际眼科杂志》2016,16(11):2095-2098
目的:对比飞秒激光制瓣的准分子激光原位角膜磨镶术( femtosecond-laser in situ keratomileusis, femto-LASIK )与传统机械板层刀制瓣的准分子激光原位角膜磨镶术( laser in situ keratomileusis,LASIK)治疗屈光不正患者术后视觉质量的变化。
  方法:回顾性病例研究。选择我院2014-01/2015-12进行屈光手术的患者89例178眼,其中使用飞秒激光制作角膜瓣患者46例92眼,使用显微角膜板层刀制作角膜瓣患者43例86眼。术后随访6mo,观察患者的视力、屈光状态、主观视觉质量评分、高阶像差等情况。
  结果:所有患者均顺利完成手术,角膜瓣均制作成功,无术中及术后并发症发生。两组患者术后不同时间裸眼视力与术前最佳矫正视力相比较,差异无统计学意义(P>0.05),两组患者术后屈光度与术前预期屈光度比较,差异具有统计学意义(P<0.05)。两组患者术后6mo主观视觉调查质量评分比较,差异有统计学意义(P<0.05)。术后6 mo飞秒激光组和机械板层刀组角膜像差均方根值、球差及彗差较术前增加,差异具有统计学意义(P<0.05),但飞秒激光组增加的幅度比机械板层刀组低,差异有统计学意义(P<0.05)。
  结论:飞秒激光制作角膜瓣更精确可靠,离散度更小,可以制作更薄的角膜瓣,飞秒激光制瓣的LASIK较传统机械板层刀LASIK术后可以获得更好的视觉质量。  相似文献   

9.
汪凌  余野  王勤美 《国际眼科杂志》2013,13(11):2202-2204
目的:对比分析飞秒激光和角膜板层刀行准分子激光原位角膜磨镶术(laser in situ keratomileusis,LASIK)术后患者的视觉质量及角膜瓣变化。方法:选取2009-03/2012-03将接受飞秒激光35例70眼患者和接受角膜板层刀的患者45例90眼进行对比研究,两组术后视觉质量和角膜瓣进行对比。结果:视觉质量比较:两组患者所行的手术均有显著的可预测性、有效性及安全性,且术后像差和对比敏感度及视力差异不显著,组间差异无统计学意义(P>0.05);角膜瓣比较:两组患者在水平方向的角膜瓣厚度组间差异无统计学意义(P>0.05)。结论:飞秒激光和角膜板层刀行LASIK术后具有良好的视觉效果,且角膜瓣厚度差异不显著,值得临床推广使用。  相似文献   

10.
目的::比较飞秒激光制瓣与角膜板层刀制瓣的LASIK术后对比敏感度变化的差异,探讨不同制瓣方式对视觉质量的影响。方法:回顾性研究,近视患者106例212眼。按手术方式不同分为两组:飞秒组(后面简称FS组)与板层刀组(后面简称SBK组)。 FS ( LASIK with femtosecond laser )组接受飞秒制瓣的 LASIK 手术,共56例112眼;SBK ( LASIK with mechanical microkeratome )组接受板层刀制瓣的LASIK手术,共50例100眼。于术前及术后1wk,3mo行对比敏感度检查,比较两组之间的对比敏感度的变化及其差异。结果:FS组及SBK组术后1 wk明视下各空间频率对比敏感均较术前明显下降,有统计学差异(均P<0.05),术后3 mo两组明视力下各空间频率对比敏感度较术前无明显统计学差异(均P>0.05),两组间各时间点差异均无统计学意义(均P>0.05)。术后1 wk FS组及SBK组暗视力下各空间频率对比敏感度较术前显著下降,有统计学差异(均P<0.05),SBK组较FS组下降更为显著,有统计学差异(均P<0.05)。术后3 mo SBK组暗视力下高空间频率(14.2c/d)对比敏感度较术前显著下降以外,其余各空间频率两组暗视力下对比敏感度较术前均无统计学差异(均P>0.05)。术后1wk两组眩光下各空间频率对比敏感度较术前显著下降,有统计学差异(均 P<0.05),SBK组较FS组下降更为显著,有统计学差异(均 P<0.05)。术后3mo除SBK组眩光下高空间频率(14.2c/d)对比敏感度较术前显著下降以外,其余各空间频率两组眩光下对比敏感度较术前均无统计学差异(均P>0.05)。结论:飞秒制瓣的LASIK手术与角膜刀制瓣的LASIK手术相比,能获得更好的视觉质量。  相似文献   

11.
AIM: To compare refractive results, higher-order aberrations (HOAs), contrast sensitivity and dry eye after laser in situ keratomileusis (LASIK) performed with a femtosecond laser versus a mechanical microkeratome for myopia and astigmatism.METHODS: In this prospective, non-randomized study, 120 eyes with myopia received a LASIK surgery with the VisuMax femtosecond laser for flap cutting, and 120 eyes received a conventional LASIK surgery with a mechanical microkeratome. Flap thickness, visual acuity, manifest refraction, contrast sensitivity function (CSF) curves, HOAs and dry-eye were measured at 1wk; 1, 3, 6mo after surgery.RESULTS:At 6mo postoperatively, the mean central flap thickness in femtosecond laser procedure was 113.05±5.89 µm (attempted thickness 110 µm), and 148.36±21.24 µm (attempted thickness 140 µm) in mechanical microkeratome procedure. An uncorrected distance visual acuity (UDVA) of 4.9 or better was obtained in more than 98% of eyes treated by both methods, a gain in logMAR lines of corrected distance visual acuity (CDVA) occurred in more than 70% of eyes treated by both methods, and no eye lost ≥1 lines of CDVA in both groups. The difference of the mean UDVA and CDVA between two groups at any time post-surgery were not statistically significant (P>0.05). The postoperative changes of spherical equivalent occurred markedly during the first month in both groups. The total root mean square values of HOAs and spherical aberrations in the femtosecond treated eyes were markedly less than those in the microkeratome treated eyes during 6mo visit after surgery (P<0.01). The CSF values of the femtosecond treated eyes were also higher than those of the microkeratome treated eyes at all space frequency (P<0.01). The mean ocular surface disease index scores in both groups were increased at 1wk, and recovered to preoperative level at 1mo after surgery. The mean tear breakup time (TBUT) of the femtosecond treated eyes were markedly longer than those of the microkeratome treated eyes at postoperative 1, 3mo (P<0.01).CONCLUSION:Both the femtosecond laser and the mechanical microkeratome for LASIK flap cutting are safe and effective to correct myopia, with no statistically significant difference in the UDVA, CDVA during 6mo follow-up. Refractive results remained stable after 1mo post-operation for both groups. The femtosecond laser may have advantages over the microkeratome in the flap thickness predictability, fewer induced HOAs, better CSF, and longer TBUT.  相似文献   

12.
目的:评价VisuMax飞秒激光与Moria One Use-Plus SBK角膜板层刀制作超薄角膜瓣的舒适性与安全性。

方法:回顾性病例系列研究。统计同期接受角膜屈光手术的778例1 556眼(VisuMax飞秒激光组即A组384例768眼,SBK角膜板层刀组即B组394例788眼),对比术中舒适度评分、角膜瓣相关并发症、角膜瓣切口出血、球结膜下出血的发生率,评价两种方法的舒适性与安全性。

结果:术中舒适度方面,感觉极不舒适,难以忍受者A组5例(1.3%),B组28例(7.1%); 术中角膜瓣切口出血A组4眼(0.5%),B组74眼(9.4%); 球结膜下出血A组18眼(2.3%),B组82眼(10.4%); 角膜瓣边缘不齐A组0眼(0),B组94(11.9%); A组有4眼(0.5%)出现角膜瓣上皮部分剥脱,但未影响成功掀瓣及手术,A组有53眼(6.9%)发生角膜层间气泡(OBL)。两组无其它相关并发症。

结论:两种方法安全可靠,均无严重影响术后视觉质量的角膜瓣相关并发症。  相似文献   


13.

目的:探讨飞秒激光与机械板层刀制瓣准分子激光角膜磨镶术(LASIK)对眼表的影响,研究制瓣方法不同对术后眼表的影响。

方法:本研究纳入对象选择2016-01/2017-01于我院眼科进行屈光手术治疗的218例436眼近视患者,进行病历资料回顾性分析,所有患者均采用LASIK术治疗,术后主诉有不同程度的眼干、异物感及不适症状。将采用机械板层刀制瓣的61例122眼患者设为对照组,观察组采用飞秒激光制瓣的157例314眼设为观察组。比较两组患眼术前、术后1wk,1、3mo干眼症状评分,角膜荧光素染色(FL)评分、泪膜破裂时间(BUT)以及基础泪液分泌试验(SⅠt)。

结果:两组患者术前干眼症状评分差异无统计学意义(P>0.05),手术前后两组患者干眼症状评分比较差异有统计学意义(P<0.05),术后1wk,对照组干眼症状评分大于观察组,两组患者干眼症状评分差异有统计学意义(P<0.05),术后1、3mo,两组干眼症状评分差异无统计学意义(P>0.05)。术前两组患者BUT比较差异无统计学意义(P>0.05),两组患者手术前后BUT差异有统计学意义(P<0.05),对照组术后BUT显著低于观察组,差异有统计学意义(P<0.05)。术前两组患者FL评分比较差异无统计学意义(P>0.05),两组患者手术前后FL评分差异有统计学意义(P<0.05),对照组术后1wk,1mo FL评分显著高于观察组,差异有统计学意义(P<0.05),术后3mo两组患者FL评分差异无统计学意义(P>0.05)。术前两组患者SⅠt比较,差异无统计学意义(P>0.05),两组患者手术前后SⅠt评分差异有统计学意义(P<0.05),对照组术后1wk,1mo SⅠt显著低于观察组,差异有统计学意义(P<0.05),术后3mo两组患者SⅠt比较,差异无统计学意义(P>0.05)。两组患者术后均无严重的并发症发生。

结论:飞秒激光较机械板层刀制瓣LASIK对眼表影响更小,干眼症症状更轻,影响时间更短。  相似文献   


14.
AIM: To evaluate the effect of age on visual and refractive results after laser in situ keratomileusis (LASIK) obtained with a mechanical microkeratome or a femtosecond laser. METHODS: Retrospective, nonrandomized, cohort study. A total of 3826 eyes were included in the study (1725 eyes treated with mechanical LASIK and 2101 eyes treated with femtosecond LASIK). The relationship between patient age and the 3-month postoperative visual and refractive results of both procedures were analyzed by linear regression analysis. RESULTS: Three months postoperatively, we found a significant correlation between age and the postoperative spherical equivalent (SE; r2=0.004, P=0.006), efficacy (r2=0.006, P=0.001), and safety indexes (r2=0.05, P=0.0001) in the mechanical LASIK group. On the other hand, we found a significant correlation between age and the postoperative SE (r2=0.02, P=0.0001) and the efficacy index (r2=0.01, P=0.0001) but not the safety index in the femtosecond laser group. Mechanical LASIK provided slightly but significantly better efficacy and predictability in patients 18 to 40 years of age and femtosecond LASIK did so in patients older than 40 years of age. The femtosecond laser provided better safety results than the mechanical microkeratome in both age groups. CONCLUSION: A tendency toward undercorrection and less predictability is found with aging after myopic LASIK regardless of whether the flap was created with a mechanical microkeratome or a femtosecond laser. However, femtosecond laser provides significantly better outcomes in terms of efficacy, safety and predictability compared to mechanical microkeratome for the correction of myopia in patients over 40y.  相似文献   

15.
AIM:To compare the outcomes of laser in situ keratomileusis (LASIK) performed with a femtosecond laser (Femtec, Technolas Perfect Vision GmbH, Germany) versus a mechanical microkeratome (Hansatome, Bausch and Lomb, USA) for the correction of myopia and astigmatism.METHODS: In this retrospective study, patients who had undergone LASIK using the 80-kHz Femtec femtosecond laser were compared to age- and refraction-matched patients in whom the Hansatome microkeratome was used. Refractive and visual results 1 month and 3 months postoperatively, and complication rates were compared between the two groups.RESULTS:A total of 280 eyes were analyzed (140 in each group).At 3 months postoperatively in the Femtec vs Hansatome group, spherical equivalent refraction was within ±1.00D of emmetropia in 140 vs 138 eyes (P=0.498), the cylinder was within ±0.50D in 137 vs 139 eyes (P=0.622), and the UDVA was 20/20 or better in 136 vs 137 eyes (P=0.724), respectively. There was no statistically significant difference in the complication rates between the two groups (P=0.099).CONCLUSION:LASIK performed both with Femtec femtosecond laser and Hansatome microkeratome achieved satisfactory refractive and visual results at 3 months postoperatively, without significant differences in efficacy, safety, and complication rates between the two procedures.  相似文献   

16.
目的:观察飞秒激光制瓣LASIK后泪膜的变化情况及视力的影响因素分析.方法:回顾性收集2014-06/2016-06我院行飞秒激光制瓣LASIK随访3mo的患者150例300眼,观察术前、术后1wk,1、2、3mo患者的干眼症状评分、泪膜破裂时间(breakup time,BUT)、泪液分泌试验(Schirmer Ⅰ test,SⅠt)、角膜荧光素染色(fluorescein staining,FL)评分的变化.结果:干眼症状评分:术前与术后3mo比较无统计学意义(P=0.863),术前与术后1wk,1、2mo比较有统计学意义(P=0.001、0.002、0.002);术后1wk与术后1mo比较无统计学意义(P=0.799),术后1wk与术后2、3mo比较有统计学意义(p=0.004).BUT:术前与术后3mo比较无统计学意义(P=0.625),术前与术后1wk、1、2mo比较有统计学意义(P=0.029、0.017、0.002);术后1wk与术后1、2mo比较无统计学意义(P=0.827、0.672),术后1mo与术后2mo比较无统计学意义(P=0.423),术后1wk,1、2mo与术后3 mo比较有统计学意义(P=0.001、0.023、0.026).FL:术前与术后3mo比较无统计学意义(P=0.521),术前与术后1wk,1、2mo比较有统计学意义(P=0.001、0.019、0.026).SⅠt:术前与术后3mo比较无统计学意义(P=0.749),术前与术后1wk,1、2mo比较有统计学意义(P=0.000、0.002、0.006);术后1wk与术后1、2mo比较无统计学意义(P=0.364、0.424),术后1wk,1、2mo与术后3mo比较有统计学意义(P=0.012、0.023、0.029).多因素回归分析显示,术后视近时间、术前眼压、眼轴长度、术前BCVA及切削比为术后影响视力恢复危险因素.结论:飞秒激光制瓣LASIK导致术后干眼的发生,但一般持续时间较短,症状较轻,在术后3 mo基本能恢复至接近术前水平,其发生机制与多种因素有关;同时,术后泪膜功能的检查结果,对术后的用药具有指导意义.  相似文献   

17.

目的:探讨FS-LASIK设置6.0mm和6.5mm两种光学区直径对术后视觉质量的影响。

方法:本研究为前瞻性研究。选取行FS-LASIK手术的患者25例50眼,随机预设置患者双眼光学区切削直径6.0mm或6.5mm,并按光学区直径分为6.0mm及6.5mm两组。术后3mo对两组患者进行Sirius三维眼前节分析系统测量角膜高阶像差(包括3、5、7mm瞳孔直径下的总高阶像差、球差、彗差及三叶草差)以及OQASⅡ视觉质量分析仪比较MTF截止空间频率(MTF cut off)、斯特列尔比值(SR)和客观散射指数(OSI)、不同模拟对比度视力(OV100%、OV20%、OV9%),并对两组患者进行OSDI干眼相关视觉质量主观问卷调查。

结果:术后3mo,3mm瞳孔直径下,两组总高阶像差、球差、彗差及三叶草差无差异(均P>0.05); 5mm瞳孔直径下,两组总高阶像差、彗差、三叶草差无差异(均P>0.05),但球差有差异(P<0.05); 7mm瞳孔直径下,两组总高阶像差、球差均有差异(均P<0.05),但彗差、三叶草差无差异(均P>0.05)。两组的OSDI问卷评分及OQASⅡ客观视觉质量各项参数均无差异(均P>0.05)。

结论:6.5mm光学区直径FS-LASIK术后暗环境的高阶像差较小,但术前设置6.0mm光学区直径或6.5mm光学区直径均能获得良好的主观及客观视觉质量。  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号