Purpose

To evaluate the impact of complex-averaging on image quality (IQ) and diagnostic accuracy of acquired and calculated high b value (aHBV, cHBV) images in diffusion-weighted prostate MRI.

Materials and methods

This retrospective study included 84 patients who underwent multiparametric prostate MRI at 3 Tesla without endorectal coil. DWIs were acquired at three different b values which included two lower b values (b = 50,900 s/mm2) and one higher b value (aHBV at 2000 s/mm2). The acquired data were postprocessed to generate two different types of trace-weighted images—using conventional magnitude-averaging and complex-averaging. Using lower b values (b = 50,900 s/mm2) from both conventional and complex-averaged image sets, cHBV images (b = 2000 s/mm2) and ADC maps were derived. All image sets were reviewed by two radiologists in different reading sessions to assess image quality and PIRADS. The diagnostic accuracy of different image sets for the detection of prostate lesions was performed by correlating PIRADS and Gleason scores.

Results

Complex-averaging did not impact ADC values of the prostate lesions compared to magnitude-averaging (P = 0.08). Complex-averaging improved image quality of acquired high b value and calculated high b value images (P < 0.0001). Complex-averaging also improved the level of confidence (LOC) of the acquired high b value for both readers (P < 0.0001, P < 0.05), but only for reader A in calculated high b value (P < 0.0001). The image quality of calculated high b value images was not significantly different than acquired high b value images. The dataset combining complex-averaging and calculated high b value provided the highest diagnostic accuracy (but not statistically significant) for detection of the significant prostate lesion compared to the magnitude-averaged acquired high b value (79.55% vs. 72.73%; P = 0.317). The mean acquisition time for b = 2000 s/mm2 sequence (aHBV) was 6 min 30 s (± 1 min 16 s) out of a total of 28 min 31 s (± 4 min 26 s) for the entire mp-MRI protocol (approximately 25% of total scan time).

Conclusion

Complex-averaging provides better image quality and level of confidence without significant impact on ADC values and diagnostic accuracy for detection of the significant prostate lesions . The calculated high b value images are also comparable to (and can substitute) the acquired high b value images which can help in reducing the imaging time.

  相似文献   

2.
Purpose

To determine the diagnostic potential of Material Density (MD) iodine images in dual-energy CT (DECT) for visualization and quantification of arterial phase hyperenhancement and washout in hepatocellular carcinomas compared to magnetic resonance imaging (MRI).

Materials and Methods

The study complied with HIPAA guidelines and was approved by the ethics committee of the institutional review board. Thirty-one patients (23 men, 8 women; age range, 36–87 years) with known or suspected Hepatocellular Carcinoma (HCC) were included. All of them underwent both single-source DECT and MRI within less than 3 months. Late arterial phase and portal venous phase CT imaging was performed with dual energies of 140 and 80 kVp, and virtual monoenergetic images (at 65 keV) and MD-iodine images were generated. We determined the contrast-to-noise ratio (CNR) for HCC in arterial phase and portal venous phase images. In addition, we introduced a new parameter which combines information of CNR in arterial and portal venous phase images into a single ratio (combined CNR). All parameters were assessed on monoenergetic 65 keV images, MD-iodine images, and MRI. Paired t test was used to compare CNR values in Mono-65 keV, MD-iodine, and MR images.

Results

CNR was significantly higher in the MD-iodine images in both the arterial (81.87 ± 40.42) and the portal venous phases (33.31 ± 27.86), compared to the Mono-65 keV (6.34 ± 4.23 and 1.89 ± 1.87) and MRI (30.48 ± 25.52 and 8.27 ± 8.36), respectively. Combined CNR assessment from arterial and portal venous phase showed higher contrast ratios for all imaging modalities (Mono-65 keV, 8.73 ± 4.03; MD-iodine, 119.87 ± 52.94; MRI, 34.87 ± 27.34). In addition, highest contrast ratio was achieved in MD-iodine images with combined CNR evaluation (119.87 ± 52.94, P < 0.001).

Conclusion

MD-iodine images in DECT allow for a quantitative assessment of contrast enhancement and washout, with improved CNR in hepatocellular carcinoma in comparison to MRI.

  相似文献   

3.
Purpose

Magnetic resonance imaging (MRI) sequences with conical k-space trajectories are able to decrease motion artifacts while achieving ultrashort echo times (UTE). We assessed the performance of free-breathing conical UTE MRI in the evaluation of the pediatric pelvis for suspected appendicitis.

Methods

Our retrospective review of 84 pediatric patients who underwent MRI for suspected appendicitis compared three contrast-enhanced sequences: free-breathing conical UTE, breath-hold three-dimensional (3D) spoiled gradient echo (BH-SPGR), and free-breathing high-resolution 3D SPGR (FB-SPGR). Two radiologists performed blinded and independent evaluations of each sequence for image quality (four point scale), anatomic delineation (four point scale), and diagnostic confidence (five point scale). Subsequently, the three sequences were directly compared for overall image quality (− 3 to + 3 scale). Scores were compared using Kruskal–Wallis and Wilcoxon signed-rank tests.

Results

UTE demonstrated significantly better perceived signal-to-noise ratio (SNR) and fewer artifacts than BH-SPGR and FB-SPGR (means of 3.6 and 3.4, 3.4 and 3.2, 3.1 and 2.7, respectively; p < 0.0006). BH-SPGR and FB-SPGR demonstrated significantly better contrast than UTE (means of 3.6, 3.4, and 3.2, respectively; p < 0.03). In the remaining categories, UTE performed significantly better than FB-SPGR (p < 0.00001), while there was no statistical difference between UTE and BH-SPGR. Direct paired comparisons of overall image quality demonstrated the readers significantly preferred UTE over both BH-SPGR (mean + 0.5, p < 0.00001) and FB-SPGR (mean + 1.2, p < 0.00001).

Conclusions

In the evaluation of suspected appendicitis, free-breathing conical UTE MRI performed better in the assessed metrics than FB-SPGR. When compared to BH-SPGR, UTE demonstrated superior perceived SNR and fewer artifacts.

  相似文献   

4.
Yano  Motoyo  Fowler  Kathryn J.  Srisuwan  Santip  Salter  Amber  Siegel  Cary L. 《Abdominal imaging》2018,43(12):3390-3399
Purpose

The purpose of the study is to evaluate the utility of apparent diffusion coefficient (ADC), chemical shift signal intensity index (SII), and contrast enhancement in distinguishing between benign lesions and renal cell carcinoma (RCC) and between subtypes of renal lesions.

Methods

This retrospective study included 98 renal lesions (≤ 3 cm) on MRI with correlative surgical pathology. Scanner field strength, lesion location, and size were recorded. Two readers blinded to surgical pathology independently measured ADC ratio (ADC lesion/ADC non-lesion kidney), SII, and absolute/relative enhancement in the corticomedullary and nephrographic phases of contrast.

Results

There were 76 malignant and 22 benign lesions. 42 RCC were clear cell (ccRCC), 19 papillary (pRCC), 5 chromophobe (cbRCC). Benign lesions included both solid and cystic lesions. Interreader agreement for all variables was good–excellent (ICC 0.70–0.91). There was no difference in ADC or SII between benign and malignant lesions. There was greater absolute corticomedullary enhancement of benign versus malignant lesions (150.0 ± 111.5 vs. 81.1 ± 74.8, p = 0.0115), which did not persist when excluding pRCC. For lesion subtype differentiation, ADCratio for pRCC was lower than benign lesions (0.74 ± 0.35 vs. 1.03 ± 0.46, p = 0.0246). ccRCC demonstrated greater SII than other RCC (0.09 ± 0.22 vs. 0.001 ± 0.26, p = 0.0412). Oncocytomas and angiomyolipoma (AML) showed greater absolute corticomedullary enhancement than ccRCC and pRCC (145.6 ± 65.2 vs. 107.2 ± 85.3, p = 0.043 and 186.2 ± 93.9 vs. 37.6 ± 35.3, p = 0.0108), respectively.

Conclusions

While corticomedullary-phase enhancement was a differentiating feature, quantitative metrics from diffusion and chemical shift imaging cannot reliably differentiate benign from malignant lesions. Quantitative assessment may be useful in differentiating some benign and malignant lesion subtypes.

  相似文献   

5.
Liu  Yiyan  Wen  Ziqiang  Yang  Xinyue  Lu  Baolan  Xiao  Xiaojuan  Chen  Yan  Yu  Shenping 《Abdominal imaging》2019,44(11):3625-3631
Purpose

To compare the diagnostic accuracies of MDCT and high-resolution MRI (HR-MRI) for regional nodal metastases with different short-axis diameter ranges in rectal cancer patients.

Methods

Rectal adenocarcinoma patients who underwent both MDCT and HR-MRI before surgery were included. The maximum short-axis diameters of the nodes were measured, and were classified as benign or malignant on imaging findings. All of the nodes were subdivided as follows: ≤ 5 mm (Group A), > 5 mm and ≤ 10 mm (Group B) , and > 10 mm (Group C). The postoperative pathological reports were used as the standard, and the sensitivity, specificity, accuracy, ROC curve, and AUC value were calculated for each subgroup.

Results

A total of 592 nodes were included in the node-to-node evaluation. In Group A, the specificity and accuracy of HR-MRI were significantly higher than those of MDCT (99.28% vs. 93.99%, P < 0.001; 95.78% vs. 89.56%, P = 0.010; respectively). In Group B, the specificity and accuracy of HR-MRI were also higher than those of MDCT (98.36% vs. 55.74%, P < 0.001; 80.45% vs. 66.17%, P < 0.001; respectively). For Groups A and B, the AUCs of MDCT were both 0.65, whereas those of HR-MRI were 0.76 and 0.82, respectively. In Group C, all nine malignant nodes were correctly diagnosed metastases on MDCT, whereas one was misjudged as benign on HR-MRI.

Conclusions

The diagnostic value of HR-MRI is superior to that of MDCT, with higher specificity, accuracy, and AUC values for HR-MRI than for MDCT.

  相似文献   

6.
Aim

To determine correlation of liver stiffness measured by MR Elastography (MRE) with biliary abnormalities on MR Cholangiopancreatography (MRCP) and MRI parenchymal features in patients with primary sclerosing cholangitis (PSC).

Methods

Fifty-five patients with PSC who underwent MRI of the liver with MRCP and MRE were retrospectively evaluated. Two board-certified abdominal radiologists in agreement reviewed the MRI, MRCP, and MRE images. The biliary tree was evaluated for stricture, dilatation, wall enhancement, and thickening at segmental duct, right main duct, left main duct, and common bile duct levels. Liver parenchyma features including signal intensity on T2W and DWI, and hyperenhancement in arterial, portal venous, and delayed phase were evaluated in nine Couinaud liver segments. Atrophy or hypertrophy of segments, cirrhotic morphology, varices, and splenomegaly were scored as present or absent. Regions of interest were placed in each of the nine segments on stiffness maps wherever available and liver stiffness (LS) was recorded. Mean segmental LS, right lobar (V–VIII), left lobar (I–III, and IVA, IVB), and global LS (average of all segments) were calculated. Spearman rank correlation analysis was performed for significant correlation. Features with significant correlation were then analyzed for significant differences in mean LS. Multiple regression analysis of MRI and MRCP features was performed for significant correlation with elevated LS.

Results

A total of 439/495 segments were evaluated and 56 segments not included in MRE slices were excluded for correlation analysis. Mean segmental LS correlated with the presence of strictures (r = 0.18, p < 0.001), T2W hyperintensity (r = 0.38, p < 0.001), DWI hyperintensity (r = 0.30, p < 0.001), and hyperenhancement of segment in all three phases. Mean LS of atrophic and hypertrophic segments were significantly higher than normal segments (7.07 ± 3.6 and 6.67 ± 3.26 vs. 5.1 ± 3.6 kPa, p < 0.001). In multiple regression analysis, only the presence of segmental strictures (p < 0.001), T2W hyperintensity (p = 0.01), and segmental hypertrophy (p < 0.001) were significantly associated with elevated segmental LS. Only left ductal stricture correlated with left lobe LS (r = 0.41, p = 0.018). Global LS correlated significantly with CBD stricture (r = 0.31, p = 0.02), number of segmental strictures (r = 0.28, p = 0.04), splenomegaly (r = 0.56, p < 0.001), and varices (r = 0.58, p < 0.001).

Conclusion

In PSC, there is low but positive correlation between segmental LS and segmental duct strictures. Segments with increased LS show T2 hyperintensity, DWI hyperintensity, and post-contrast hyperenhancement. Global liver stiffness shows a moderate correlation with number of segmental strictures and significantly correlates with spleen stiffness, splenomegaly, and varices.

  相似文献   

7.
Purpose

The purpose of the study was to determine if enhancement features and qualitative imaging features on multiphasic multidetector computed tomography (MDCT) were associated with tumor grade in patients with clear cell renal cell carcinoma (ccRCC).

Methods

In this retrospective, IRB approved, HIPAA-compliant, institutional review board-approved study with waiver of informed consent, 127 consecutive patients with 89 low grade (LG) and 43 high grade (HG) ccRCCs underwent preoperative four-phase MDCT in unenhanced (UN), corticomedullary (CM), nephrographic (NP), and excretory (EX) phases. Previously published quantitative (absolute peak lesion enhancement, absolute peak lesion enhancement relative to normal enhancing renal cortex, 3D whole lesion enhancement and the wash-in/wash-out of enhancement within the 3D whole lesion ROI) and qualitative (enhancement pattern; presence of necrosis; pattern of; tumor margin; tumor–parenchymal interface, tumor–parenchymal interaction; intratumoral vascularity; collecting system infiltration; renal vein invasion; and calcification) assessments were obtained for each lesion independently by two fellowship-trained genitourinary radiologists. Comparisons between variables included χ2, ANOVA, and student t test. p values less than 0.05 were considered to be significant. Inter-reader agreement was obtained with the Gwet agreement coefficient (AC1) and standard error (SE) was reported.

Results

No significant differences were observed between the LG and HG ccRCC cohorts with respect to absolute peak lesion enhancement and relative lesion enhancement ratio. There was a significant inverse correlation between low and high grade ccRCC and tumor enhancement the NP (71 HU vs. 54 HU, p < 0.001) and EX (52 HU vs. 39 HU, p < 0.001) phases using the 3D whole lesion ROI method. The percent wash-in of 3D enhancement from the UN to the CM phase was also significantly different between LG and HG ccRCCs (352% vs. 255%, p = 0.003). HG lesions showed significantly more calcification, necrosis, collecting system infiltration and ill-defined tumor margins (p < 0.05). Overall agreement between the two readers had a mean AC1 of 0.8172 (SE 0.0235).

Conclusions

Quantitatively, high grade ccRCC had significantly lower whole lesion enhancement in the NP and EX phases on MDCT. Qualitatively, high grade ccRCC were significantly more likely to be associated with calcifications, necrosis, collecting system infiltration, and an ill-defined tumor margin.

  相似文献   

8.
Kim  Sung Mo  Shin  Sang Soo  Lee  Byung Chan  Kim  Jin Woong  Heo  Suk Hee  Lim  Hyo Soon  Jeong  Yong Yeon 《Abdominal imaging》2017,42(10):2527-2537
Purpose

To prospectively compare multidetector-row CT (MDCT) and MR imaging (MRI) in the assessment of the ablative margin (AM) and index tumor immediately after radiofrequency (RF) ablation for hepatocellular carcinoma (HCC) and assess whether non-contrast MRI with limited sequences (T1- and T2-weighted imaging only) was superior to a conventional MDCT protocol.

Methods

A total of 33 consecutive patients with 42 HCCs were included in this study. Both MDCT and MR images were independently reviewed by two radiologists regarding the ability to visually discriminate between the AM and index tumor, and the AM status within ablation zones. The AM status was classified as AM-plus (AM completely surrounding the tumor), AM-zero (AM was partly discontinuous, without protrusion of the tumor), and AM-minus (AM was partly discontinuous, with protrusion of the tumor). During the follow-up period, the cumulative local tumor progression rates were analyzed using the Kaplan–Meier method and Cox proportional hazards model. To determine the added value of contrast-enhanced MR images, both reviewers separately evaluated the two sets (unenhanced and enhanced) of MR images.

Results

Visual discrimination between the AM and index tumor was possible in four (9.5%) and 34 (81%) of the 42 ablation zones using MDCT and MRI, respectively (p < 0.001). Thirty-eight and four cases were classified as AM-plus and AM-zero on MDCT images, respectively, whereas the ablation zones were categorized as AM-plus (n = 32), AM-zero (n = 9), and AM-minus (n = 1) when examining the MR images. The cumulative incidence of local tumor progression was significantly lower in cases with AM-plus on MRI (p = 0.007). Contrast-enhanced MRI had no added value for the assessment of the AM and index tumor.

Conclusion

MRI was superior to MDCT for the differential assessment of the AM and index tumor immediately after RF ablation for HCC. Non-contrast MRI was also superior to the conventional MDCT protocol.

  相似文献   

9.
Purpose

The purpose of the study was to correlate lung shunt fraction (LSF) calculated by intra-arterial injection of Technetium-99m (Tc-99m)-labeled macroaggregated albumin (MAA) in a hepatic artery branch with the presence of certain patterns of vascular shunts on dynamic CT or MRI of the liver.

Methods

This retrospective study was approved by the institutional review board and informed consent was waived. We reviewed 523 MAA scans in 453 patients (301 men, 152 women) performed from July 2007 to June 2015 and their correlative cross-sectional imaging. Patterns of vascular shunts on dynamic CT or MRI performed within 3 months of the MAA study and that potentially divert hepatic arterial inflow to the systemic venous return were defined as “target shunts.” Dynamic CT or MRI was classified into three groups with target shunt present, absent, or indeterminate. The mean LSF was compared across the first and second groups using paired t test.

Results

342 CT and MRI studies met inclusion criteria: target shunts were present in 63 studies, absent in 271 studies, and 8 studies were indeterminate. When target shunts were visualized, the mean LSF on corresponding MAA scans was 12.9 ± 10.36% (95% CI 10.29–15.15%) compared to 4.3 ± 3.17% (95% CI 3.93–4.68%) when no target shunt was visualized. The difference was statistically significant (p value < 0.001). Identified target shunts were either direct (arteriohepatic venous shunt) or indirect (arterioportal shunt combined with a portosystemic shunt).

Conclusions

Visualizing certain patterns of vascular shunting on a dynamic CT or MRI scan is associated with high LSF.

  相似文献   

10.
Zhang  Hongtao  Pan  Jingjing  Shen  Yanguang  Bai  Xu  Wang  Yingwei  Wang  Haiyi  Ye  Huiyi 《Abdominal imaging》2019,44(1):239-246
Purpose

To assess the usefulness of morphological characteristics of diffusion-weighted imaging (DWI) for differentiating malignant renal tumors from benign renal tumors, and clear cell renal cell carcinoma (RCC) from non-clear cell RCC at 3.0 T.

Methods

The study included 249 patients with 251 histopathologically confirmed renal tumors that showed high signal on DWI. For each tumor, two radiologists independently evaluated apparent diffusion coefficient (ADC) values and morphological characteristics of DWI. The differences in the quantitative and qualitative magnetic resonance imaging (MRI) features determined by the readers were assessed. The ADC values between malignant and benign renal tumors and between clear cell and non-clear cell RCC were compared using Mann–Whitney tests. The proportional differences of morphological characteristics of DWI between malignant and benign renal tumors and between clear cell and non-clear cell RCC were compared using Chi-square tests.

Results

There were no significant differences in the quantitative and qualitative MRI features determined by the readers. The ADC values for malignant renal tumors were statistically significantly higher than those for benign renal tumors (p < 0.05), and the ADC values for clear cell RCC were statistically significantly higher than those for non-clear cell RCC (p < 0.05). The proportion of morphological characteristics of DWI between malignant and benign renal tumors was statistically significantly different at ring, nodular, flaky high signal. The proportion of morphological characteristics of DWI between clear cell and non-clear cell RCC was statistically significantly different at uniform high signal.

Conclusions

The morphological characteristics of DWI are useful in differentiating renal tumors.

  相似文献   

11.
Purpose

To describe and validate a novel CT approach using volumetric analysis for renal stone surveillance.

Materials and methods

This prospective trial consisted of a standard low-dose non-contrast CT (SLD) of the abdomen and pelvis, immediately followed by an ultra-low-dose non-contrast CT (ULD) with reconstruction limited to the kidneys. A novel dedicated software tool was applied that automates stone volume, density, and maximum linear size. Manual linear stone size was measured by a radiology fellow and urology resident for comparison. CT dose and clinical charges were considered.

Results

Twenty-eight stones in 16 patients were analyzed. Mean effective dose of ULD CT was 0.57 mSv, an average 92% lower than the SLD CT dose. For SLD, mean size ± SD (range) (mm) was 7.9 ± 6.2 (2.6–30.5) for Reader 1, 7.3 ± 6 (2.4–30.7) for Reader 2, and 9.3 ± 6.4 (3.7–33.1) for the automated software. For ULD, mean size ± SD (range) (mm) was 7.3 ± 6 (2.5–30.5) for Reader 1, 7.2 ± 6.1 (2.1–30.7) for Reader 2, and 9.1 ± 6.4 (4.2–32.8) for the automated software. Automated stone diameters were larger than manual diameters for 27/28 stones (mean difference, 23%); difference was ≥ 2 mm in 30%. Average variability between manual measurements was 8.6% (SLD) and 7.8% (ULD), but was 0% for the automated technique. Our institutional charge for ULD renal CT is slightly less than renal US, and > 4× less than SLD CT. The Medicare global fee for the ULD renal CT is less than the SLD CT of the abdomen and pelvis.

Conclusions

This focused stone surveillance CT protocol is lower cost and lower dose compared to the standard CT approach. Automated assessment of stone burden provides improved reproducibility over manual linear measurement and offers the advantages of 3D measurements and volumetry. We now offer and perform this protocol in routine clinical practice for stone surveillance.

  相似文献   

12.
Purpose

The purpose of the study was to determine if the ≥ 15 mm threshold currently used to define PIRADS 5 lesions is the optimal size threshold for predicting high likelihood of clinically significant (CS) cancers.

Materials

Three hundred and fifty-eight lesions that may be changed from category 4 to 5 or vice versa on the basis of the size criterion (category 4: n = 288, category 5: n = 70) from 255 patients were evaluated. Kendall’s tau-b statistic accounting for inter-lesion correlation, generalized estimation equation logistic regression, and receiver operating curve analysis evaluated two lesion size-metrics (lesion diameter and relative lesion diameter—defined as lesion diameter/prostate volume) for ability to identify CS (Gleason grade ≥ 3 + 4) cancer at targeted biopsy. Optimal cut-points were identified using the Youden index. Analyses were performed for the whole prostate (WP) and zone-specific sub-cohorts of lesions in the peripheral and transition zones (PZ and TZ).

Results

Lesion diameter showed a modest correlation with Gleason grade (WP: τB = 0.21, p < 0.0001; PZ: τB = 0.13, p = 0.02; TZ: τB = 0.32, p = 0.001), and association with CS cancer detection (WP: AUC = 0.63, PZ: AUC = 0.59, TZ: AUC = 0.74). Empirically derived thresholds (WP: 14 mm, PZ: 13 mm, TZ: 16 mm) performed similarly to the current ≥ 15 mm standard. Lesion relative lesion diameter improved identification of CS cancers compared to lesion diameter alone (WP: τB = 0.30, PZ: τB = 0.24, TZ: τB = 0.42, all p < 0.0001). AUC also improved for WP and PZ lesions (WP: AUC = 0.70, PZ: AUC = 0.68, and TZ: AUC = 0.74).

Conclusions

The current ≥ 15 mm diameter threshold is a reasonable delineator of PI-RADS category 4 and category 5 lesions in the absence of extraprostatic extension to predict CS cancers. Additionally, relative lesion diameter can improve identification of CS cancers and may serve as another option for distinguishing category 4 and 5 lesions.

  相似文献   

13.
Cao  Xiaojing  Liu  Zhenxing  Zhou  Xiang  Geng  Chengyun  Chang  Qing  Zhu  Li  Feng  Wenqi  Xu  Tianyu  Xin  Yujing 《Abdominal imaging》2019,44(1):310-317
Purpose

To evaluate the utility of real-time contrast-enhanced ultrasound (CEUS)-guided coaxial needle biopsies for focal liver lesions (FLL) that were inconspicuous or could not be accurately identified the active site on B-mode ultrasound (US).

Materials and methods

This prospective study included 76 patients who had CEUS-guided coaxial needle biopsies for FLL between December 2015 and June 2017. We recorded characteristics of target lesions. We evaluated conspicuity of target lesions and accuracy of identifying the active site of target lesions on B-mode US and CEUS using a 5-point scale. Patients were divided into three groups, and analyzed according to body mass index (BMI). Based on the final diagnosis, the diagnostic performance was evaluated.

Results

The mean size and depth of target lesions were 41.5 ± 28.5 and 47.9 ± 18.9 mm on CEUS, respectively. In arterial phase, the enhanced pattern of target lesions varied. The conspicuity of target lesions and accuracy of identifying the active site of target lesions was significantly improved on CEUS compared to B-mode US (p < 0.05). The three BMI groups had significant differences in conspicuity of target lesions after using CEUS (p < 0.05). The high BMI group had a greater change in conspicuity of lesions compared to the normal BMI group or the low BMI group (p < 0.05). The sensitivity, specificity, and accuracy of this technique for the diagnosis of FLL were 92.8%, 100%, and 93.4%, respectively.

Conclusion

Real-time CEUS-guided coaxial needle biopsy can be very useful for FLL that are inconspicuous or cannot be accurately identified the active site on B-mode US.

  相似文献   

14.
Objective

To correlate the findings on 3T multiparametric prostate MRI using PIRADS version 2 with prostate biopsy results as the standard of reference.

Materials and methods

134 consecutive treatment naive patients (mean age 64 years, range 41–82 years) underwent MRI-directed prostate biopsy. MRI–TRUS fusion biopsy was used for 77 (77/134 = 57.5%) patients, cognitive fusion for 51 (51/134 = 38.0%) patients, and 6 patients (6/134 = 4.5%) without a target nodule had systematic biopsy only. Out of the 1676 biopsy sites, 237 (237/1676 = 14.1%) were positive on MRI for a PIRADS 3, 4, or 5 nodule. Fifty-eight (58/134, 43.3%) patients had clinically significant prostate cancer (csPCa). The findings on MRI using PIRADS version 2 were correlated with the biopsy results.

Results

The accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of PIRADS ≥ 3 for csPCa were 89%, 76.5%, 89.7%, 31.7%, and 98.4%, respectively. The detection rates of csPCa for PIRADS 3, 4, and 5 nodules were 6.1% (4/66), 33.3% (42/126), and 64.4% (29/45), respectively. MRI did not identify a nodule in 23/1676 (1.4%) biopsy sites that contained csPCa. The MRI reader, biopsy operator, method of fusion biopsy, and zonal location of prostate nodule did not significantly affect the odds of having a biopsy result positive for csPCa.

Conclusion

PIRADS ≥ 3 had high specificity and high negative predictive value for csPCa using biopsy results as the standard of reference. The presence of csPCa from a biopsy site was highly unlikely in the absence of a corresponding PIRADS ≥ 3 nodule.

  相似文献   

15.
Purpose

The goal of our study is to compare hepatic stiffness measures using gradient-recalled echo (GRE) versus spin-echo echo planar imaging (SE-EPI)-based MR Elastography (MRE) at 3T used to measure hepatic stiffness in a patients with suspected liver diseases.

Materials and methods

This retrospective study included 52 patients with liver disease who underwent a 3T MRE exam including both an investigational SE-EPI-based technique and a product GRE-based technique. Regions of interest (ROI) were placed on the elastograms to measure elastography-derived liver stiffness as well as the area included within the ROIs. The mean liver stiffness values and area of ROIs were compared.

Results

The mean liver stiffness was 3.72 kilopascal (kPa) ± 1.29 using GRE MRE and 3.78 kPa ± 1.13 using SE-EPI MRE. Measurement of liver stiffness showed excellent agreement between the two pulse sequences with a mean bias of − 0.1 kPa (range − 1.8 to 1.7 kPa) between sequences. The mean measurable ROI area was higher with SE-EPI (313.8 cm2 ± 213.8) than with the GRE technique (208.6 cm2 ± 114.8), and the difference was statistically significant (P < 0.05).

Conclusions

Our data shows excellent agreement of measured liver stiffness between GRE and SE-EPI-based sequences at 3T. Our results show the advantage of a SE-EPI MRE sequence in terms of image quality, ROI size and acquisition time with equivalent liver stiffness measurements as compared to GRE-MRE sequence.

  相似文献   

16.
Purpose

To evaluate the diagnostic performance of superparamagnetic iron-oxide (SPIO)-enhanced diffusion-weighted image (DWI) for distinguishing an intrapancreatic accessory spleen from pancreatic tumors.

Materials and methods

Twenty-six cases of intrapancreatic accessory spleen and nine cases of pancreatic tail tumors [neuroendocrine tumor (n = 8) and pancreatic adenocarcinoma (n = 1)] were analyzed. Two blind reviewers retrospectively reviewed the SPIO-enhanced magnetic resonance imaging (MRI) scans. The lesion visibility grades were compared and the diagnostic performance of SPIO-enhanced DWI was compared to those of SPIO-enhanced T2WI and T2*WI with the use of a receiver operating characteristic (ROC) analysis.

Results

The grade of lesion visibility was the highest on DWI [mean ± standard deviation (SD): 2.8 ± 0.3] followed by T2WI (2.3 ± 0.7, p < 0.001) and T2*WI (2.1 ± 0.7, p < 0.0001). Reviewers 1 and 2 correctly characterized the presence or absence of SPIO uptake in 34 of 35 cases (97.1%) on DWI, 24 (68.6%) and 25 (71.4%) cases on T2WI, respectively, and 16 (45.7%) and 17 (48.6%) cases on T2*WI. The area under the ROC curve (AUC) of DWI was 0.974 and 0.989 for reviewers 1 and 2, respectively. For Reviewer 1, the AUC of DWI was significantly higher than that of T2*WI (0.756, p < 0.01), although it was not significantly different from that of T2WI (0.868, p = 0.0857). For Reviewer 2, the AUC of DWI was significantly higher than those of T2WI (0.846, p < 0.05) and T2*WI (0.803, p < 0.01).

Conclusion

The diagnostic performance of SPIO-enhanced DWI was better than those of SPIO-enhanced T2*WI and T2WI for the diagnosis of intrapancreatic accessory spleen.

  相似文献   

17.
Purpose

To investigate [11C]acetate PET-surrogate parameter of fatty acid synthase activity—as suitable tool for diagnosis and monitoring of liver steatosis.

Methods

In this retrospective study, data were obtained from 83 prostatic carcinoma patients from 1/2008 to 1/2014. Mean HU was calculated from unenhanced CT of all patients from liver with liver HU less than 40 as threshold for liver steatosis. SUVmax of the liver and of the blood pool in thoracic aorta (as background for calculation of a liver/background ratio [SUVl/b]) was measured. t test was used with a P < 0.05 considered as statistically significant difference and ROC analysis was used for calculating specificity and sensitivity.

Results

19/83 patients (20%) had diagnosis of hepatic steatosis according to CT. Uptake of [11C]acetate was significantly higher in patients with hepatic steatosis as compared to control group (SUVmax 7.96 ± 2.0 vs. 5.48 ± 2.3 [P < 0.001]). There was also a significant correlation between both SUVmax (r = − 0.52, P < 0.001) and SUVl/b (r = − 0.59, P < 0.001) with the density (HU) of the liver. In ROC analysis for detection of liver steatosis SUVmax (threshold: 5.86) had a sensitivity of 94% and specificity of 69% with an AUC of 0.81. Increasing body mass index is correlated with the severity of steatosis.

Conclusion

We showed for the first time that hepatic steatosis associates with increased [11C]acetate uptake. Also, severity of steatosis correlates with [11C]acetate uptake. [11C]acetate uptake PET seems promising for the assessment of liver steatosis.

  相似文献   

18.
Cheng  Wei  Zhang  Shaoyi  Wang  Jian  Zhou  Changsheng  Li  Yousheng  Li  Jieshou 《Abdominal imaging》2018,43(11):2955-2962
Purpose

To evaluate the feasibility and accuracy of remnant small intestinal length measured by barium follow-through (BaFT) examination and three-dimensional CT enterography (CTe).

Materials and methods

Twenty-nine consecutive short bowel syndrome patients (SBS) who underwent BaFT, CTe, and prior surgical measurements of small intestine were included. Measurements of total remnant small intestinal length on BaFT and CTe were compared to surgical measurements using Spearman's rank correlation coefficients, Bland–Altman plots, and paired t test.

Results

The average remnant intestinal length was 73.1 ± 37.2 cm according to surgical measurement. There was a significant positive correlation between CTe and surgical measurement (r2 = 0.99; p < 0.0001), and a relatively weaker correlation between BaFT and surgical measurement (r2 = 0.71; p < 0.001). Compared with surgical measurement, the percentage differences of CTe and BaFT were 5.71 ± 6.71% and 27.14 ± 18.41% (mean ± SD), respectively. Furthermore, Bland–Altman plots showed good agreement between CTe and surgical measurement, whereas relatively poor agreement between BaFT and surgical measurement. However, significant difference was found among the three measurement methods by paired t test (p < 0.0001).

Conclusions

Assessment of remnant small intestinal length by CTe is accurate and acceptable for clinical application, whereas BaFT is less accurate although BaFT is more convenient and cheaper for clinical application. And CTe can provide a cost-effective and noninvasive determination of remnant small intestinal length in planning surgical and nutritional intervention in SBS patients.

  相似文献   

19.
Purpose

To compare dual-energy CT (DECT) iodine overlay images with renal mass protocol CT in the evaluation of polycystic kidneys with respect to reading time, diagnostic confidence, and detection of renal lesions that are not definitively benign.

Methods

Following IRB approval, portal venous phase dual-source DECT scans performed between September 2013 and February 2016 from 55 patients (mean age 67 ± 15 years, 31 male, 24 female) with polycystic kidneys (4 or more cysts) were included. For each patient, two image sets were created: (1) DECT post-processed iodine overlay images and (2) simulated renal mass protocol CT images (virtual noncontrast and mixed images). Two radiologists independently retrospectively reviewed both sets at separate time points, evaluating for the presence of lesions that were not definitively benign (enhancing lesions or Bosniak IIF cysts), as well as reading times and Likert scale diagnostic confidence ratings (scaled 1–5) for the presence of non-benign lesions. Reading times were compared with a t test, diagnostic confidence with a McNemar test, and lesion number detection with Cohen’s kappa test.

Results

Iodine overlay images were read faster (mean 55 ± 26 s) than renal mass protocol (mean 105 ± 51 s) (p < 0.001). Readers assigned the highest diagnostic confidence rating in 64% using iodine overlay series, compared to 17% using renal mass protocol (p < 0.0001). The proportion of patients with recorded lesions was not significantly different between methods (p = 0.62).

Conclusions

DECT improves lesion assessment in polycystic kidneys by decreasing reading times and increasing diagnostic confidence, without affecting lesion detection rates.

  相似文献   

20.
Purpose

To evaluate whole-lesion ADC histogram metrics for assessing the malignant potential of pancreatic intraductal papillary mucinous neoplasms (IPMNs), including in comparison with conventional MRI features.

Methods

Eighteen branch-duct IPMNs underwent MRI with DWI prior to resection (n = 16) or FNA (n = 2). A blinded radiologist placed 3D volumes-of-interest on the entire IPMN on the ADC map, from which whole-lesion histogram metrics were generated. The reader also assessed IPMN size, mural nodularity, and adjacent main-duct dilation. Benign (low-to-intermediate grade dysplasia; n = 10) and malignant (high-grade dysplasia or invasive adenocarcinoma; n = 8) IPMNs were compared.

Results

Whole-lesion ADC histogram metrics demonstrating significant differences between benign and malignant IPMNs were: entropy (5.1 ± 0.2 vs. 5.4 ± 0.2; p = 0.01, AUC = 86%); mean of the bottom 10th percentile (2.2 ± 0.4 vs. 1.6 ± 0.7; p = 0.03; AUC = 81%); and mean of the 10–25th percentile (2.8 ± 0.4 vs. 2.3 ± 0.6; p = 0.04; AUC = 79%). The overall mean ADC, skewness, and kurtosis were not significantly different between groups (p ≥ 0.06; AUC = 50–78%). For entropy (highest performing histogram metric), an optimal threshold of >5.3 achieved a sensitivity of 100%, a specificity of 70%, and an accuracy of 83% for predicting malignancy. No significant difference (p = 0.18–0.64) was observed between benign and malignant IPMNs for cyst size ≥3 cm, adjacent main-duct dilatation, or mural nodule. At multivariable analysis of entropy in combination with all other ADC histogram and conventional MRI features, entropy was the only significant independent predictor of malignancy (p = 0.004).

Conclusion

Although requiring larger studies, ADC entropy obtained from 3D whole-lesion histogram analysis may serve as a biomarker for identifying the malignant potential of IPMNs, independent of conventional MRI features.