首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Right atrial aneurysm (RAA) is a very rare anomaly. Rarer still is its association with atrial septal defect (ASD). We reported a case of a 42-year-old woman with giant RRA and secundum type ASD detected by means of transthoracic echocardiography.  相似文献   

2.
This study investigated the difference of atrial electrophysiologic characteristics between a normal and dilated atrium and compared them among patients with paroxysmal atrial fibrillation and flutter. Twenty-seven patients with paroxysmal atrial fibrillation and 28 patients with paroxysmal atrial flutter were divided into four subgroups, according to the presence of a normal atrium or bilateral atrial enlargement. Thirty patients without atrial arrhythmia (20 patients with normal atrium and 10 patients with bilateral atrial enlargement) were included in control group. The atrial refractoriness in patients with a dilated atrium was longer than those with normal atrial size. In patients with paroxysmal atrial fibrillation and patients of control group, the P-wave duration and interatrial conduction velocity with or without atrial enlargement were similar. However, in patients with paroxysmal atrial flutter, P-APCS (86 ± 10 ms vs. 73 ± 9 ms, p < 0.05) and P-ADCS (109 ± 9 ms vs. 95 ± 9 ms, p < 0.05) in patients with a dilated atrium were longer than in patients with a normal atrium. The patients with paroxysmal atrial fibrillation or atrial flutter all demonstrated longer P-wave duration and interatrial conduction time than control group. Among the groups with a normal atrium or a dilated atrium, atrial refractoriness in patients with paroxysmal atrial flutter was shorter than that in control group. Moreover, in the patients with a normal atrium, the potential minimal wavelength in control group (6.6 ± 1.7) was longer than that of paroxysmal atrial fibrillation (5.3 ± 1.1), or atrial flutter (5.0 ± 1.2). These findings suggest that atrial electrophysiologic characteristics of a dilated atrium were different from those of normal atrium, and these changes were different between paroxysmal atrial fibrillation and flutter. Multiple factors are considered to be related to the genesis of atrial tachyarrhythmias.  相似文献   

3.
The preoperative differentiation of a thrombus from a myxoma is important but not always easy. Clinical and echocardiographic characteristics of myxoma and thrombi are not diverse enough to always reliably distinguish the two. We report the case of a patient who was found to have a left atrial appendage thrombus that was misdiagnosed as a myxoma on the basis of its imaging characteristics on cardiac magnetic resonance in addition to the detection of dense neovascularization on coronary angiography. This case highlights the unusual features of an organized thrombus that can mimic many of the distinguishing characteristics of a myxoma.  相似文献   

4.
INTRODUCTION: This study evaluated the safety and efficacy of a new dual-chamber implantable cardioverter defibrillator (ICD) to detect and treat atrial tachyarrhythmias in patients with drug-refractory atrial fibrillation (AF) and no indication for a ventricular ICD. METHODS AND RESULTS: A dual-chamber ICD (Medtronic 7250 Jewel AF) was implanted in 144 of 146 patients. The device discriminates atrial tachycardia from AF based on cycle length and regularity, and uses atrial overdrive pacing as well as shocks to terminate tachyarrhythmia episodes. Patients were followed for an average of 12.6+/-6.2 months. Use of antiarrhythmic drugs was 63% at baseline and did not change over time. Kaplan-Meier estimates of 12-month complication-free survival, device therapy survival, and patient survival were 85%, 91%, and 98%, respectively. Positive predictive accuracy of spontaneous atrial tachyarrhythmia detection was 99%, while atrial overdrive pacing and shocks terminated 40% and 87% of treated episodes, respectively. Median duration of successfully treated episodes was 8.9 minutes versus 144 minutes for the therapy failures. There was no reduction in the use of patient-activated shock therapy over time; at the 12-month follow-up evaluation, 94% of patients were in sinus rhythm. Ventricular tachyarrhythmias (67 episodes) were detected and appropriately treated in 7.6% of patients. CONCLUSION: This dual-chamber ICD appears to be safe and well tolerated in patients with drug-refractory symptomatic atrial tachyarrhythmias. The device, used in combination with drugs, effectively treats atrial tachyarrhythmias with pacing and/or shock therapies and decreases the median episode duration. In addition, the device protects from ventricular tachyarrhythmias in patients with AF and structural heart disease.  相似文献   

5.
AIM: The purpose of this study was to investigate the role of transoesophageal echocardiography in predicting subsequent thromboembolic events in patients with atrial fibrillation. METHODS AND PATIENTS: Transoesophageal echocardiography was performed in 88 patients with documented paroxysmal (n=53) or chronic atrial fibrillation (n=35) to assess morphological and functional predictors of thromboembolic events. Prospective selection was from patients with non-valvular atrial fibrillation who had undergone transoesophageal echocardiography because of previous thromboembolism (n=30); prior to electrical cardioversion (n=31); or for other reasons (n=27). All patients were followed up for 1 year. RESULTS: During the period of follow-up new thromboembolic events occurred in 18 of 88 patients (20%/year); 16 of these patients had a stroke and two a peripheral embolism. Univariate analysis revealed that previous thromboembolism (P<0.005; odds ratio 5.3 [CI 1.9, 12. 1]), history of hypertension (P<0.01; odds ratio 4.0 [CI 1.4, 10.4), presence of left atrial spontaneous echo contrast (P<0.025; odds ratio 3.5 [CI 1.2, 10.0]), and presence of left atrial appendage peak velocity 相似文献   

6.
Atrial Tachycardia from a Single Site. We describe the case of a patient who has a right atrial tachycardia and atrial fibrillation who was found to have a single site responsible for both. We recorded a tachycardia from this site with exit block into the remainder of the atria.  相似文献   

7.
Thromboemoblism is the most feared complication of atrial fibrillation. Percutaneous left atrial appendage occlusion is a new interventional procedure for reducing thromboembolic risk in patients with atrial fibrillation. The paper reports of a post mortem analysis of the device demonstrating that one year after implantation the atrial surface of the device is completely covered by neo-endothelium and the device occludes the appendage completely.  相似文献   

8.
In patients with conventional indication for ICD implantation, atrial fibrillation may occur in more than 50% during the life-span of the device and may lead to severe adverse events. Dual chamber defibrillators with atrial antitachycardia functions, including prevention algorithms, arrhythmia detection capability and atrial therapy options (antitachy pacing and cardioversion) have been recently introduced. The aim of this review is to examine the effectiveness of these new devices and to identify patients who may benefit. We recently studied 112 patients who received the device because of life-threatening ventricular arrhythmias. Fifty-five percent of them had atrial fibrillation prior to implantation. During the follow-up (one year on average), 27% had at least one episode of sustained atrial tachyarrhythmia. Effectiveness of atrial antitachy pacing was 71% on regular atrial tachycardia and 36% on irregular atrial tachyarrhythmias. Atrial shock efficacy was over 90% when adequately programmed. Interestingly, near half of the episodes started as regular atrial tachycardia and accelerated and became less organized in few minutes. Early delivery of antitachy pacing may increase success rate and decrease the need for atrial shock. Furthermore, it may prevent atrial remodeling and reduce atrial fibrillation burden.Based on our experience, we recommend that all patients with a class I indication for defibrillator implantation (related to risk of ventricular arrhythmias) who have a history of or are at risk of developing atrial tachyarrhythmias should receive a dual chamber defibrillator equipped with atrial antitachycardia functions. Furthermore, patients either with a history of heart failure, with poor functional capacity (functional class III or IV), depressed left ventricular ejection fraction, a need for monitoring of atrial rhythm, or in whom there is some concern about appropriate detection of ventricular arrhythmias, may benefit from a single device capable of managing ventricular and supraventricular arrhythmias.  相似文献   

9.
Tachycardia-Induced Cardiomyopathy. Introduction: Two years after orthotopic cardiac transplantation, a 60-year-old man presented with unexplained congestive heart failure and an incessant atrial tachycardia.
Methods and Results: Electrophysiologic evaluation identified the underlying arrhythmia as automatic atrial tachycardia with site of origin at the high anterior lateral right atrial wall. Radiofrequency catheter ablation successfully eliminated the tachycardia, which resulted in prompt improvement of this patient's congestive heart failure.
Conclusion: This is the first reported case of tachycardia-induced cardiomyopathy in a cardiac transplant patient. Radiofrequency catheter ablation can he used successfully in this patient population.  相似文献   

10.
With the widespread use of transoesophageal echocardiography, atrial septal aneurysm (ASA) is frequently and easily recognized. Diagnostic criteria, however, remain arbitrary. A meticulous search for interatrial shunting (most often patent foramen ovale (PFO)) and associated cardiac diseases is important. ASA is considered a risk factor for cardioembolism, especially in association with patent foramen ovale. We describe a patient with a giant multiperforated ASA presenting with refractory paroxysmal atrial fibrillation. Resection of the aneurysm was performed in combination with a surgical Maze procedure.  相似文献   

11.
INTRODUCTION: Implantable atrial defibrillators (IADs) have proved to be safe and effective in the management of atrial fibrillation. A potential limitation of self-activated IAD therapy is patient-reported pain and anxiety. The main objective of the present study was to determine whether triazolam improved patient perception of the shock experience or altered patient memory of shock discomfort relative to placebo. METHODS AND RESULTS: A total of 15 men and women (mean age: 59 +/- 6 years) were enrolled in this double-blind, placebo-controlled, crossover study of triazolam. Randomized study medication was administered orally 75 minutes prior to scheduled atrial shock delivery. Patient perception of the shock experience was assessed along with sedation, memory, anxiety, and mood. Triazolam reduced mean pre-shock anxiety (t= 2.98, df = 14, P = 0.01) and shock-related pain (t= 2.74, df = 13, P = 0.01) and intensity (t= 2.64, df = 13, P = 0.018) relative to placebo. Similarly, participants recalled less discomfort the morning after shock with triazolam than with placebo (t= 2.82, df = 11, P = 0.017). CONCLUSIONS: This study was the first to investigate the use of an oral benzodiazepine administered prior to patient-activated shock delivery with an IAD. Our data indicate that oral triazolam is beneficial in decreasing pain and anxiety associated with self-activated atrial defibrillation. If triazolam provides a similar benefit in the community to that which has been reported here, this medication could be offered to patients as an adjunct to intermittent IAD therapy.  相似文献   

12.
A case of profound sistemic oxigen desaturation after atrial septostomy in a patient with primitive pulmonary hypertension is reported. A new method to correct such severe complication of atrial septostomy is described, consisting in a graded reduction of the right to left atrial shunt by deployment of a manually perforated atrial septal closure device.  相似文献   

13.

Background

Despite the indisputable role of anticoagulation therapy for atrial fibrillation (AF) patients at risk for stroke, anticoagulants remain under-used in everyday clinical practice. We assumed that by performing trans-oesophageal echocardiography (TEE) on patients with AF who were not on anticoagulation treatment prior to the procedure, and by explaining to them the TEE images obtained, as well as the possible consequences of these findings, we could convince patients to start anticoagulation therapy. The main objective of the study was to assess the examined patients’ adherence to warfarin therapy over a two-year period.

Methods and results

We conducted a prospective TEE study from February 2006 to December 2008 on 70 patients with chronic AF who were not on anticoagulation treatment. Mean patient age was 65.85 ± 10.02 years and 68.57% were women. Thrombus in the left atrial appendage was found in 25 (35.71%) patients. Fifty-four (77.14%) patients had thrombi or spontaneous echo contrast in at least one of their supraventricular cavities.Following the procedure and with detailed explanation to the patients of their TEE findings, we managed to start anticoagulation therapy on 60 (85.71%) patients. At the end of the follow-up period of 23.76 ± 2.8 months, 53 (75.71%) patients remained on warfarin therapy. The rest of the surviving patients settled for thrombo-prophylaxis with aspirin.

Conclusion

TEE is a valuable method that, in addition to its diagnostic possibilities, could also serve as a convincing visual method of putting atrial fibrillation patients onto an anticoagulation regimen.  相似文献   

14.
A 79‐year‐old woman underwent transesophageal echocardiography to evaluate the severity of her mitral regurgitation prior to urgent bypass. Evaluation of the right‐sided chambers was notable for a mass in the right atrial appendage (RAA). Surgical excision and pathologic examination proved this to be a thrombus. This is the first reported case of a RAA thrombus in a patient with normal sinus rhythm and normal right ventricular (RV) function. It illustrates that complete transesophageal studies may sometimes demonstrate incidental findings, and that right atrial thrombus can (rarely) be found in patients in sinus rhythm with normal RV function.  相似文献   

15.
Common atrium (CA), also called three-chambered heart, is one of the rare congenital anomalies, defined by a complete absence of the atrial septum, eventually associated with malformation of the atrioventricular (AV) valves. We report the case of a 57-year-old woman with CA complicated with Eisenmenger syndrome and inferior vena cava interruption, who suffered from symptomatic persistent atrial fibrillation (AF). She underwent an initial successful pulmonary vein isolation procedure. A repeat procedure for perivalvular atrial flutter was complicated with inadvertent complete AV block, due to unusual AV node location in this challenging anatomy.  相似文献   

16.
Completion of Mitral Isthmus Ablation. Background: Although mitral isthmus (MI) ablation in atrial fibrillation (AF) patients has been shown to be an effective ablative strategy, the establishment of the bidirectional conduction block of the MI is technically challenging. We investigated the usefulness of a steerable sheath for MI ablation in patients with persistent AF and its impact on the clinical outcome of persistent AF ablation. Methods: A total of 80 consecutive patients undergoing MI ablation were randomized to 1 of the following 2 groups: group S (using a steerable long sheath) or group NS (using a nonsteerable long sheath). MI ablation was performed by using an open‐irrigated ablation catheter with the guidance of a 3‐dimensional mapping system. The endpoint of the MI ablation was the achievement of a bidirectional block. Results: Bidirectional block through the MI was achieved in 87.5% (70/80) of patients with 14.0 ± 6.7 minutes of radiofrequency application. The bidirectional block was more frequently achieved in patients in group S compared to group NS (97.5% (39/40) vs 77.5% (31/40), P = 0.02). Additionally, epicardial ablation within the coronary sinus was less frequently required in group S compared to group NS (12.5% (5/40) vs 72.5% (29/40), P < 0.0001). Atrial tachycardia after the procedure more frequently occurred in the patients in whom MI block had not been achieved during the initial procedure (40.0% (4/10) vs 10.0% (7/70), P = 0.04). Conclusions: The MI block could be achieved in the majority of patients by using a steerable sheath. An incomplete MI block increased the risk of AT following persistent AF ablation. (J Cardiovasc Electrophysiol, Vol. 22, pp. 1331‐1338, December 2011)  相似文献   

17.
Abstract: Right atrial thrombus simulating myxoma on M-mode echocardiography in a patient with pulmonary emboli. E. G. Whitford, R. W. Harper, J. Federman, A. Skoien, S. T. Anderson and A. Pitt. Aust. N.Z. J. Med., 1982, 12 , pp. 543–545.
Echoes from a right atrial mass in a patient with pulmonary embolism simulated a typical echocardiography appearance of a right atrial myxoma. The patient was admitted with recurrent pulmonary emboli and had evidence of deep venous thrombosis on venography. M-mode echocardiography showed the appearance of a right atrial mass and right atrial angiography confirmed the presence of amass prolapsing from right atrium into right ventricle.
Subsequent 2-dimensional echocardiography and careful repeat M-mode echocardiography failed to demonstrate the mass suggesting embolisation to the lungs or lysis of the thrombus.  相似文献   

18.
A 24 h intravenous dosing regimen of amiodarone was designedto reach a peak plasma concentration at 1 h and to maintainthe concentration above a certain level during the infusionperiod A randomized, open-label, digoxin-controlled study wasundertaken to observe the efficacy and safety of the dosingregimen of amiodarone in treating recent-onset, persistent,atrial fibrillation and flutter with ventricular rates above130 beats. min–1. Fifty patients with a mean age of 70± 7 (SD) years were enrolled and randomly assigned toreceive either amiodarone intravenously (n=26) or digoxin (n=24).Amiodarone HCl was infused over 24 h according to the followingregimen: 5 mg. min–1, 3 mg. min–1, 1 mg. min–1and 0.5 mg. min–1 for 1, 3, 6 and 14 h, respectively,for a 70-kg subject. Digoxin (0.013 mg. kg–1) was infusedin three divided doses, each dose 2 h apart and infused over30 min. The mean heart rates in the amiodarone group decreased significantlyfrom 157 ± 20 beats. min–1 to 122 ± 25 beats.min–1 after 1 h (P<005 vs baseline), and then decreasedfurther to stabilize at 96 ± 25 beats. min–1 after6 h (P<0.05). The digoxin group had fewer dramatic alterationsin heart rates, compared to the amiodarone group, in the first8h (P<0.05, respectively). Maximum reduction was reachedonly after 8 h. The amiodarone infusion was prematurely abortedin two patients due to severe bradycardia and death after conversionin one patient and aggravation of heart failure in the other.Overall, 24 of 26 patients (92%) in the amiodarone group and17 of 24 (71%) in the digoxin group were restored to sinus rhythmwithin 24 h. The accumulated rates of conversion over 24 h weresignificantly different between the two groups (P=0.0048). Digoxin,while not as effective as amiodarone in the treatment of recent-onsetatrial fibrillation and flutter, appears to be safer. Therefore,we suggest the use of digoxin as the first line drug for thetype of patients that formed the basis of the current studyand reserve amiodarone for refractory cases or those in whomdigoxin is not suitable.  相似文献   

19.
20.
Summary. We report a case of left atrial myxoma associated with a fluctuating level of cryofibrinogen. Her initial symptoms and signs were consistent with primary cryofibrinogenaemia, but a repeat episode occurred without the cryofibrinogen being detectable. A more typically embolic cerebro-vascular accident (CVA) occurred, with the subsequent discovery of the patient's myxoma. The cryofibrinogen was again present but it disappeared with resection of the myxoma. We propose that the degree of activation of the coagulation system around the myxoma fluctuated, causing variable conversion of fibrinogen to fibrin, so that at times partially cross-linked fibrin(ogen) resulted in cryofibrinogen, but at other times frank emboli from more complete clotting occurred.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号