首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Platelet adhesion under static and flow conditions from a washed platelet suspension containing albumin to a polymer deposited by radio-frequency glow discharge of allylamine vapour on a poly(ethylene terephthalate) substrate was measured. Electron spectroscopy for chemical analysis was used to characterize the surface. Fibrinogen adsorption from a series of dilute plasma solutions to radio-frequency glow discharge/allylamine, measured using 125I radiolabelled baboon fibrinogen, increased with decreasing plasma dilution to a level much higher than that previously observed on polyurethanes. Elutability by sodium dodecyl sulphate of fibrinogen adsorbed from dilute plasma also increased with increasing plasma concentration, but fibrinogen preadsorbed from plasma became non-elutable when surfaces were stored in buffer for 5 d before contact with sodium dodecyl sulphate. Platelet adhesion to substrates which had been pre-adsorbed with dilute plasma was measured using baboon platelets radiolabelled with 111In. Adhesion greatly decreased as the plasma concentration used for preadsorption increased, suggesting that non-specific platelet binding to the bare surface occurs when protein coverage is incomplete. Non-specific platelet binding was inhibited to varying degrees by preadsorption of different proteins to the surface. Platelet adhesion to surfaces preadsorbed with dilute (1.0%) baboon and human plasmas lacking fibrinogen (i.e. serum, heat-defibrinogenated plasma and congenitally afibrinogenemic plasma) was diminished compared with normal plasma. Addition of exogenous fibrinogen to the deficient plasma partially restored platelet adhesion to normal levels. Adhesion to surfaces preadsorbed with human plasma deficient in von Willebrand factor was comparable to that observed with normal plasma. The plasma preadsorption studies with fibrinogen deficient media suggested that adsorbed fibrinogen is necessary for platelet adhesion to the radio-frequency glow discharge/allylamine substrate at high protein coverage. However, since adhesion was greatly reduced when the plasma preadsorbed substrate was stored in buffer before platelet contact, the conformation of adsorbed fibrinogen is also important in mediating platelet adhesion to radio-frequency glow discharge.  相似文献   

2.
Fibrinogen adsorption from blood to biomaterials may regulate platelet adhesion and thrombus formation because of fibrinogen's central role in the coagulation cascade and its ability to bind specifically to the platelet membrane glycoprotein (GP) IIb-IIIa. Adsorption of fibrinogen from blood plasma to many materials exhibits a maximum with respect to plasma dilution and exposure time (the Vroman effect). In this study fibrinogen adsorption to several polymers was examined to ascertain the influence of controlled changes in surface chemistry on the Vroman effect. The materials included hydroxyethylmethacrylate-ethylmethacrylate (HEMA/EMA) copolymers, Biomer, and a series of segmented polyurethanes (PEUs), two of which contained fluorinated chain extenders. Each material exhibited maximal adsorption of fibrinogen at intermediate plasma concentrations. Little effect of soft-segment type or molecular weight was observed and no significant differences in fibrinogen adsorption to the fluorinated PEUs were seen. Changes in the strength of fibrinogen attachment to these materials with time after adsorption were also assessed. Fibrinogen adsorbed for 1 min was displaced more readily by blood plasma than that adsorbed for 1 h, regardless of the material. The more hydrophobic polymers exhibited greater retention of adsorbed fibrinogen. In addition, the fraction of fibrinogen retained by polyethylene depended on the amount of fibrinogen adsorbed to the surface, being greatest when the surface loading was the least. These studies indicate that spreading or transition of adsorbed fibrinogen molecules from a weakly to tightly bound state is a general consequence of protein adsorption to solid surfaces.  相似文献   

3.
The adsorption of fibrinogen from both human whole blood and plasma to a number of "foreign" surfaces is reported. Adsorption was measured as a function of plasma or blood dilution using radioiodine labeling. We showed previously that adsorption of fibrinogen from plasma exhibits a maximum at a plasma dilution of about 100:1, and have attributed this behavior to competition from other plasma proteins. (The same phenomenon is manifest as a time transient in fibrinogen adsorption.) In the present work we show that exactly the same trends are observed in whole blood. For each of the four surfaces, glass, siliconized glass, collagen-coated glass and polyethylene, the adsorption of fibrinogen as a function of dilution is the same in whole blood as in plasma. Each of these surfaces shows a unique dependence of fibrinogen adsorption on plasma or blood dilution. On cuprophane and a hydrophilic polyether urethane there is essentially no adsorption of fibrinogen from blood or plasma. For the hydrophilic polyurethane this result may be artifactual, but the absence of fibrinogen binding to cuprophane in blood or plasma is real since fibrinogen is found to be adsorbed in monolayer amounts from buffer.  相似文献   

4.
The conformation adopted by the plasma protein fibrinogen upon its adsorption onto synthetic surfaces has been implicated to play an important role in determining the blood compatibility of biomaterials. It has recently been shown that adsorbed fibrinogen undergoes biologically significant conformational changes with increasing residence time on the surface of selected biomaterials. The purpose of this study was to examine the effects of co-adsorbed proteins and shear forces on such time-dependent functional changes in fibrinogen adsorbed onto polyethylene (PE), polytetrafluoroethylene (PTFE), and silicone rubber (SR). Fibrinogen was adsorbed onto these materials for 1 min and then allowed to 'reside' on these surfaces for up to 2 h prior to assessing its biological activity. Changes in fibrinogen reactivity were determined by measuring the adhesion of 51Cr-labeled platelets and the ability of blood plasma to displace previously adsorbed fibrinogen. The magnitude of platelet adhesion to substrates adsorbed with pure fibrinogen increased in the presence of shear, compared with static conditions; at the lowest shear rate of 200 s(-1), samples exhibited a 20-fold increase in adhered platelet levels. In contrast, at a higher shear rate of 1000 s(-1), the three polymers supported minimal levels of platelet attachment. Surfaces pre-adsorbed with 10% plasma did not promote a significant increase in the number of adherent platelets with increasing shear when compared with the pure fibrinogen-coated substrates. The presence of shear also significantly altered the materials' ability to retain fibrinogen. Under static conditions, the amount of fibrinogen retained following incubation in blood plasma increased on all materials with increasing fibrinogen residence time. However, the materials varied distinctly in their ability to retain adsorbed fibrinogen with increasing fibrinogen residence time, shear rate, and nature of the co-adsorbed proteins. Thus, the results from this study indicate that fluid shear, residence time of the adsorbed protein, nature of the co-adsorbed proteins, and surface chemistry of the material all play important roles in influencing platelet-surface interactions and that they act in a complex manner to influence the biocompatibility of a material.  相似文献   

5.
Fibrinolytic polyurethane surfaces were prepared by conjugating lysine to the distal terminus of surface-grafted poly(ethylene glycol) (PEG). Conjugation was through the α-amino group leaving the ε-amino group free. Lysine in this form is expected to adsorb both plasminogen and t-PA specifically from blood. It was shown in previous work that the PEG spacer, while effectively resisting nonspecific protein adsorption, was a deterrent to the specific binding of plasminogen. In the present work, the effects of PEG spacer chain length on the balance of nonspecific and specific protein binding were investigated. PEG–lysine (PEG-Lys) surfaces were prepared using PEGs of different molecular weight (PEG300 and PEG1000). The lysine-derivatized surfaces with either PEG300 or PEG1000 as spacer showed good resistance to fibrinogen in buffer. The PEG300-Lys surface adsorbed plasminogen from plasma more rapidly than the PEG1000-Lys surface. The PEG300-Lys was also more effective in lysing fibrin formed on the surface. These results suggest that the optimum spacer length for protein resistance and plasminogen binding is relatively short. Immunoblots of proteins eluted after plasma contact confirmed that the PEG–lysine surface adsorbed plasminogen while resisting most of the other plasma proteins. The hemocompatibility of the optimized PEG–lysine surface was further assessed in whole blood experiments in which fibrinogen adsorption and platelet adhesion were measured simultaneously. Platelet adhesion was shown to be strongly correlated with fibrinogen adsorption. Platelet adhesion was very low on the PEG-containing surfaces and neither surface-bound lysine nor adsorbed plasminogen promoted platelet adhesion.  相似文献   

6.
Residence time-dependent changes in fibrinogen after adsorption to six different polyurethanes were examined by measuring polyclonal antifibrinogen binding to the adsorbed protein. The amount of adsorbed fibrinogen that could be eluted by sodium dodecyl sulfate (SDS) was also measured. Baboon fibrinogen was first adsorbed from dilute plasma to the polymers, which were then stored in either buffer or buffered albumin solution prior to testing. Subsequently, the amount of antifibrinogen bound by the adsorbed fibrinogen was measured using a direct enzyme linked immunosorbent assay (ELISA). Alternatively, the surface with the adsorbed fibrinogen was soaked in a 3% SDS solution, and the amount of retained 125I-radiolabeled fibrinogen was measured. With increasing residence time, decreases in both antibody binding and the SDS elutability of the adsorbed fibrinogen occurred, but the rate of change was dependent on the polyurethane to which the fibrinogen was adsorbed. In addition, the antibody binding per unit of adsorbed fibrinogen, when measured immediately after the adsorption step, varied by approximately a factor of 3 among the various polyurethanes. When the protein-coated surfaces were stored in buffered albumin solution rather than buffer, the decrease in the reactivity of fibrinogen with residence time did not occur on some of the surfaces. This study shows that the chemical properties of the adsorbing surface influence the rate at which adsorbed fibrinogen undergoes change. The significance of the polymer-dependent changes in adsorbed fibrinogen with respect to blood reactions with polymers is discussed.  相似文献   

7.
Human plasma fibrinogen adsorption and platelet adhesion to polystyrene.   总被引:5,自引:0,他引:5  
The purpose of this study was to further investigate the role of fibrinogen adsorbed from plasma in mediating platelet adhesion to polymeric biomaterials. Polystyrene was used as a model hydrophobic polymer; i.e., we expected that the role of fibrinogen in platelet adhesion to polystyrene would be representative of other hydrophobic polymers. Platelet adhesion was compared to both the amount and conformation of adsorbed fibrinogen. The strategy was to compare platelet adhesion to surfaces preadsorbed with normal, afibrinogenemic, and fibrinogen-replenished afibrinogenemic plasmas. Platelet adhesion was determined by the lactate dehydrogenase (LDH) method, which was found to be closely correlated with adhesion of 111In-labeled platelets. Fibrinogen adsorption from afibrinogenemic plasma to polystyrene (Immulon I(R)) was low and <10 ng/cm2. Platelet adhesion was absent on surfaces preadsorbed with afibrinogenemic plasma when the residual fibrinogen was low enough (<60 microg/mL). Platelet adhesion was restored on polystyrene preadsorbed with fibrinogen-replenished afibrinogenemic plasma. Addition of even small, subnormal concentrations of fibrinogen to afibrinogenemic plasma greatly increased platelet adhesion. In addition, surface-bound fibrinogen's ability to mediate platelet adhesion was different, depending on the plasma concentration from which fibrinogen was adsorbed. These differences correlated with changes in the binding of a monoclonal antibody that binds to the Aalpha chain RGDS (572-575), suggesting alteration in the conformation or orientation of the adsorbed fibrinogen. Platelet adhesion to polystyrene preadsorbed with blood plasma thus appears to be a strongly bivariate function of adsorbed fibrinogen, responsive to both low amounts and altered states of the adsorbed molecule.  相似文献   

8.
In the past several years, atomic force microscopy (AFM) has provided topographic images of adsorbed plasma proteins in situ at unprecedented resolution. Imaging has been limited to adsorbed protein on relatively smooth model substrates such as mica, graphite, or self-assembled monolayers on which the small height of the protein can be observed from the background. The inherent roughness of biomaterial surfaces has prevented observation of adsorbed proteins in topographic images. We report imaging isolated fibrinogen molecules adsorbed on National Heart Lung and Blood Institute (NHLBI) reference materials polydimethylsiloxane and low-density polyethylene in situ using phase imaging AFM. Fibrinogen, a plasma protein important for blood coagulation and platelet aggregation, was adsorbed from dilute solution onto reference biomaterial surfaces at sub-monolayer coverage. Tapping mode AFM was used to image the samples. For polydimethylsiloxane, the lateral size of the surface features is much greater than the dimensions of proteins. This allowed adsorbed proteins to be observed in topographic images. The phase imaging signal of tapping mode AFM provides information on differences in material properties of the surface, and was used to distinguish individual protein molecules from the underlying polymer surface. On the low-density polyethylene surface, characteristic topographical features are of the same magnitude as the protein molecules, so that protein cannot be distinguished from the surface using topographic images. However, phase images were used to successfully locate and characterize the distribution of the protein. Phase imaging was not able to distinguish fibrinogen adsorbed onto expanded polytetrafluoroethylene. The utility and limitations of the phase imaging technique for characterizing protein adsorption to rough surfaces is discussed.  相似文献   

9.
Chen H  Zhang Z  Chen Y  Brook MA  Sheardown H 《Biomaterials》2005,26(15):2391-2399
Polydimethylsiloxane elastomers were surface modified with passivating polyethylene oxide (PEO) polymers of different molecular weights, both monofunctional and bifunctional. Following the introduction of Si-H groups on the surfaces by acid-catalyzed equilibration in the presence of polymethylhydrosiloxane, the PEO was linked by platinum-catalyzed hydrosilylation. ATR-FTIR, X-ray photoelectron spectroscopy (XPS) and water contact angle results confirmed that the PEO was successfully grafted to the silicone rubber. Atomic force microscopy and XPS suggested that surface coverage with PEO was very high on the modified surfaces but not complete. The protein-resistant properties of the PEO-modified surfaces were demonstrated by measuring the adsorption of fibrinogen from both buffer and plasma. Fibrinogen adsorption from buffer to the PEO-modified surfaces was reduced by more than 90% compared with controls.  相似文献   

10.
Previously we observed that platelets adherent to surfaces preadsorbed with blood plasma exhibited 1.3 to 2.4 times greater procoagulant activity than platelets on surfaces adsorbed with fibrinogen (Fg) only. These observations suggested that the adhesion proteins adsorbed from plasma may activate platelets in a cooperative, or synergistic manner. In the present study, polystyrene surfaces adsorbed with both Fg and vWF induced up to three times greater procoagulant activity than surfaces adsorbed with Fg or vWF only. The amounts of Fg and vWF adsorbed from binary mixtures that resulted in increased procoagulant activity were found to be similar to the amounts that adsorbed to PS from 100% plasma. The effect of adsorbed adhesion proteins on platelet spreading was also investigated. The proportion of fully spread platelets increased, depending on the adhesion protein preadsorbed to the surface, in the following order: vWF < Fg < Fn < (vWF + Fg) < Vn < plasma.  相似文献   

11.
Monocytes and macrophages play important roles in host responses to implanted biomedical devices. Monocyte and macrophage interactions with biomaterial surfaces are thought to be mediated by adsorbed adhesive proteins such as fibrinogen and fibronectin. Non-fouling surfaces that minimize protein adsorption may therefore minimize monocyte adhesion, activation, and the foreign body response. Radio-frequency glow discharge plasma deposition (RF-GDPD) of tetraethylene glycol dimethyl ether (tetraglyme) was used to produce polyethylene oxide (PEO)-like coatings on a fluorinated ethylene-propylene (FEP) surface. Electron spectroscopy for chemical analysis (ESCA) and static time of flight secondary ion mass spectrometry (ToF-SIMS) were used to characterize the surface chemistry of tetraglyme coating. Fibrinogen adsorption to the tetraglyme surface was measured with 125I-labeled fibrinogen and ToF-SIMS. Adsorption of fibrinogen to plasma deposited tetraglyme was less than 10 ng cm(-2), a 20-fold decrease compared to untreated FEP or tissue culture polystyrene (TCPS). Monocyte adhesion to plasma deposited tetraglyme was significantly lower than adhesion to FEP or TCPS. In addition, when the surfaces were preadsorbed with fibrinogen, fibronectin, or blood plasma, monocyte adhesion to plasma deposited tetraglyme after 2 h or 1 day was much lower than adhesion to FEP. RF-GDPD tetraglyme coating provides a promising approach to make non-fouling biomaterials that can inhibit non-specific material-host interactions and reduce the foreign body response.  相似文献   

12.
Fluorocarbon radio-frequency glow-discharge (RFGD) treatment has previously been shown to cause decreased platelet adhesion despite the presence of adsorbed fibrinogen on the surfaces. In this study platelet adhesion to fluorocarbon RFGD-treated surfaces preadsorbed with human plasma was further examined. A series of plasma deposited fluorocarbon thin films were made by varying the C3F6/CH4 ratio in the monomer feed. The surfaces were preadsorbed with plasma, serum, or plasma selectively depleted of fibronectin, vitronectin, or Von Willebrand factor, and platelet adhesion was measured. We also measured fibrinogen adsorption to the surfaces from plasma, monoclonal antibody binding to adsorbed fibrinogen and SDS elutability of the adsorbed fibrinogen. The antibodies used bind to the three putative platelet binding sites on fibrinogen, namely, M1 antibody binds to the dodecapeptide at the C-terminus of the gamma chain, gamma (402-411), R1 antibody binds to a sequence in the Aalpha chain (87-100) which includes RGDF at Aalpha (95-98) and R2 antibody binds a sequence in the Aalpha chain (566-580) which includes RGDS at Aalpha (572-575). Fibrinogen was found to play a decisive role in mediating platelet adhesion to the fluorocarbon surfaces contacting plasma. Few platelets adhered to the fluorocarbon surfaces preadsorbed with serum, while preadsorption with plasma selectively-depleted of either fibronectin, vitronectin, or von Willebrand factor did not decrease platelet adhesion significantly. Replenishment of exogenous fibrinogen to serum restored platelet adhesion, while replenishment of the other proteins had no effect. Platelet adhesion to the fluorocarbon surfaces was lower than to PET or the methane glow-discharge-treated PET. However, there was no apparent correlation between platelet adhesion and the amount of fibrinogen adsorption or monoclonal antibody binding to surface-bound fibrinogen.  相似文献   

13.
Residence-time-dependent changes in fibrinogen after its adsorption to Biomer were examined by measuring platelet adhesion and antibody binding to the adsorbed protein, and the amount of adsorbed fibrinogen which could be eluted by sodium dodecyl sulfate (SDS). Baboon fibrinogen was first adsorbed (from either pure solution or dilute plasma) to Biomer, which was then stored in either buffer or buffered albumin solution prior to testing. Subsequently, the adherent protein layer was either probed for fibrinogen capable of mediating platelet adhesion using 111In radiolabeled, washed platelet suspensions under both static and shearing conditions, or for fibrinogen capable of binding antibody using a direct enzyme linked immunosorbent assay (ELISA). Alternatively, the surface with the adsorbed protein layer was soaked in a 3% SDS solution, and the amount of 125I radiolabeled fibrinogen retained was measured. Decreases in platelet and antibody binding, and in the SDS elutability of the adsorbed fibrinogen after it was stored in buffer were detected, although different rates of decrease were observed for each method. When the protein-coated surfaces were stored in buffered albumin solution rather than buffer, the decrease in the reactivity of fibrinogen was prevented. While each of the three assays measures a different property of adsorbed fibrinogen, this study suggests that the adherent protein undergoes time dependent conformational changes which render it less reactive toward platelets and antibodies, and more resistant to elution by SDS.  相似文献   

14.
Fibrinogen adsorption and more recently fibrin formation at interfaces has been reported to depend on surface properties of the underlying substrate. To provide insight into the surface-dependent mechanism of fibrinopeptide A (FpA) release and fibrin formation, the accessibility and susceptibility of FpA to thrombin-catalyzed fibrinopeptide cleavage were examined using polyclonal anti-FpA IgG binding and surface plasmon resonance (SPR). The amount of accessible FpA on adsorbed fibrinogen was significantly influenced by surface properties of the underlying substrate (methyl- and carboxyl-terminated self-assembled monolayers). Roughly 2.7 times more FpA was available on fibrinogen adsorbed at the hydrophobic vs. negatively charged surface. Upon exposure of adsorbed fibrinogen to thrombin, 100% of the available FpA was enzymatically cleaved at both surfaces, indicating that the extent of FpA release and fibrin formation is a function of the surface-dependent FpA availability. The results presented herein suggest negatively charged surfaces impair FpA accessibility, and therefore lead to reduced FpA release and subsequent fibrin formation. As such, negatively charged surfaces may be useful in minimizing surface-induced thrombosis initiated via fibrin formation thereby aiding in the development of more biocompatible blood-contacting devices.  相似文献   

15.
Monocytes and macrophages play critical roles in inflammatory responses to implanted biomaterials. Monocyte adhesion may lead to macrophage activation and the foreign body response. We report that surface chemistry, preadsorbed proteins, and adhesion time all play important roles during monocyte adhesion in vitro. The surface chemistry of tissue culture polystyrene (TCPS), polystyrene, Primaria, and ultra low attachment (ULA) used for adhesion studies was characterized by electron spectroscopy for chemical analysis. Fibrinogen adsorption measured by (125)I-labeled fibrinogen was the lowest on ULA, higher on TCPS, and the highest on polystyrene or Primaria. Monocyte adhesion on protein preadsorbed surfaces for 2 h or 1 day was measured with a lactate-dehydrogenase method. Monocyte adhesion decreased over time. The ability of preadsorbed proteins to modulate monocyte adhesion was surface dependent. Adhesion was the lowest on ULA, higher and similar on TCPS or polystyrene, and the highest on Primaria. Monocyte adhesion on plasma or fibrinogen adsorbed surfaces correlated positively and linearly to the amount of adsorbed fibrinogen. Preadsorbed fibronectin, immunoglobulin G, plasma, or serum also promoted adhesion compared with albumin preadsorbed or uncoated surfaces. Overall, biomaterial surface chemistry, the type and amount of adsorbed proteins, and adhesion time all affected monocyte adhesion in vitro.  相似文献   

16.
It has generally been accepted that biomaterials adsorbing the least amount of the plasma protein fibrinogen following exposure to blood will support less platelet adhesion and therefore exhibit less thrombogenicity. Several studies suggest, however, that the conformation or orientation of immobilized fibrinogen rather than the total amount adsorbed plays an important role in determining the blood compatibility of biomaterials. The purpose of this study was to investigate time-dependent functional changes in fibrinogen adsorbed to polytetrafluoroethylene (PTFE), polyethylene (PE), and silicone rubber (SR). Fibrinogen was adsorbed to these materials for 1 min and then allowed to 'reside" on the surfaces for up to 2 h prior to assessing its biological activity. Changes in fibrinogen reactivity were determined by measuring the adhesion of 51Cr-labeled platelets, the binding of a monoclonal antibody (mAb) directed against an important functional region of the fibrinogen molecule (the gamma-chain dodecapeptide sequence 400-411), and the ability of blood plasma to displace previously adsorbed fibrinogen. Platelet adhesion differed among the polymeric materials studied, and PTFE and PE samples exhibited a small decrease in adhesion with increasing fibrinogen residence time. Platelet adhesion to SR was the least among all materials studied and showed no variation with residence time. When using PTFE and SR as substrates, mAb recognition of adsorbed fibrinogen did not change with residence time whereas that on PE decreased slightly. The mAb binding was least to fibrinogen adsorbed to SR, which is in agreement with the platelet adhesion results. Finally, the ability of plasma to displace previously adsorbed fibrinogen decreased dramatically with increasing residence time on all materials. These in vitro studies support the hypothesis that fibrinogen undergoes biologically significant conformational changes upon adsorption to polymeric biomaterials, a phenomenon that may contribute to the hemocompatibility of the materials following implantation in the body.  相似文献   

17.
Surface modification of a segmented polyurethane was achieved by blending with novel PEO-containing amphiphilic triblock copolymers (PEO-polyurethane-PEO). Three copolymers having different PEO MW (550, 2000, 5000) were used as surface modification additives. The protein resistance of the blend surfaces was evaluated using radiolabeling methods. On the blends of copolymers with PEO blocks of MW 2000 and 5000, fibrinogen adsorption from physiologic buffer decreased with increasing copolymer content up to 20 wt%. On the blends with PEO blocks of MW 550, resistance to adsorption for a given copolymer content was much greater. For all three blend types at 20% copolymer content, reductions in adsorption compared to the unmodified PU matrix were greater than 95%. Reductions in adsorption were similar for the 20% blends and surfaces prepared by coating the copolymers directly on the matrix, suggesting that the 20% blend surfaces were completely covered by copolymer. At low copolymer content (< or =10 wt %), fibrinogen adsorption decreased with decreasing PEO block length. This was probably due to increasing surface coverage of the copolymers with decreasing block length. It is therefore concluded that surface density of PEO is more important than PEO MW for the protein resistance of these surfaces. Lysozyme, a much smaller protein, showed adsorption trends similar to fibrinogen. The adsorption of fibrinogen and lysozyme from binary solutions to blends of the copolymer with PEO blocks of 2000 MW was investigated to probe the effects of protein size on adsorption resistance. Fibrinogen and lysozyme showed similar fractional decreases in adsorption relative to the PU matrix independent of the surface density of PEO. However lysozyme was enriched in the surface relative to the solution, that is, it was adsorbed preferentially to fibrinogen.  相似文献   

18.
The effects of certain purified plasma proteins on the coagulation-activation and platelet-adhesion properties of glass surfaces have been investigated. Albumin, transferrin, γG globulin, γM globulin and fibrinogen were obtained in highly purified form; ceruloplasmin was a more crude preparation. Each of these proteins was found to adhere to glass surfaces and influence reactions of these surfaces with blood. γG globulin or albumin adsorbed to glass markedly inhibited activation of the intrinsic coagulation system, while the other proteins tested were much less effective in this respect. Fibrinogen, of all the proteins tested, greatly enhanced the adhesion of platelets to glass. Albumin, ceruloplasmin, transferrin, γG globulin and γM globulin each decreased the adhesion of platelets to glass by approximately 50%. Ultrastructural studies of the interface area where blood reacted with the layer of protein adsorbed to glass demonstrated the deposition of a moderately thick irregular protein layer upon the surface, with adhesion of cellular elements to this unilaminar adsorbed layer. Ultrastructural studies also demonstrated that platelets which adhere to protein-coated surfaces formed pseudopods and spread upon such surfaces.  相似文献   

19.
The influence of polyurethane sulfonation on fibrinogen adsorption from plasma and on plasma coagulation has been investigated. Sulfonated polyurethanes were synthesized using a two-step solution polymerization in which a diamino disulfonic acid was used as chain extender, thus incorporating sulfonate groups into the hard segments. Polymer molecular weights were determined by size exclusion chromatography and weight average values were in the range of 50,000 to 200,000. Equilibrium water uptake of solid polymer specimens was substantial and was found to increase with increasing sulfonate content. Titration of sulfonate groups allowed an estimate of the retention of free sulfonate in the polymers which ranged from 50 to 85%. Loss of free sulfonate is attributed to reaction of isocyanate with sulfonate groups during chain extension. Both surface chemistry and hydrophilicity were assessed using a combination of ESCA and water contact angle measurements. The ESCA data indicate enrichment of soft segment in the surface. Contact angles show increasing hydrophilicity with increasing sulfur content. Fibrinogen adsorption from plasma to the sulfonated polyurethane surfaces was studied using radioiodine labeling. Fibrinogen surface concentration was found to increase strongly as sulfonate content increased. Fibrinogen adsorption behavior is quite different from that of conventional unsulfonated polyurethanes in the sense that the adsorption levels are much higher and there is little displacement of initially adsorbed fibrinogen (Vroman effect). The data are interpreted in terms of two mechanisms: fibrinogen uptake (i.e., absorption) into a polymer-plasma "gel" hypothesized to exist at the surface of these materials, and adsorption in the usual sense. Thrombin times of human plasma in which polymer particles were suspended were prolonged and were found to increase with increasing sulfonate content of the polymers, suggesting that sulfonate groups confer a measure of anticoagulant activity on these materials.  相似文献   

20.
The long-term function of implantable biosensors is limited by the foreign-body reaction (FBR). Since the acute phase of the FBR involves macrophage attachment mediated by adsorbed fibrinogen, preadsorption, and retention of other proteins might reduce the FBR. The retention of preadsorbed albumin, hemoglobin, von Willebrand's factor, and high-molecular-weight kininogen was therefore measured after exposure to plasma. The retention of preadsorbed proteins after incubation with monocyte cultures and implantation in rats was also measured. Fibrinogen adsorption from plasma to the preadsorbed surfaces was also measured. Hemoglobin adsorption was higher than that for other proteins, and it also had the greatest retention after exposure to blood plasma. When surfaces preadsorbed with hemoglobin were incubated with monocytes, more of the hemoglobin was displaced than that after incubation in plasma, while still more hemoglobin was displaced when the surfaces were implanted in vivo. Protein preadsorption on polystyrene greatly reduced fibrinogen adsorption. However, polyurethane surfaces used for glucose sensors had low fibrinogen adsorption compared with polystyrene, and this low level was not further reduced by preadsorption with other proteins. Preadsorbed proteins on polymers appear to be removed by passive exchange and/or displacement by plasma proteins and by proteases released by monocytes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号