首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到2条相似文献,搜索用时 0 毫秒
1.
Polystyrene (PS) latex particles of different sizes were adsorption coated with the polymeric surfactant Pluronic F108 (PEO129-PPO56-PEO129). The commercial surfactant was found to have a bimodal molecular weight distribution. However, the maximum surface concentrations resulting from adsorption of either the purified high molecular weight component or the composite were identical. An increase in the copolymer surface concentration on 252-nm particles was found to decrease their fibrinogen uptake exponentially. At maximum copolymer surface concentration, the fibrinogen uptake was two orders of magnitude lower than that of bare particles (down from 3.3 mg/m2 to 0.03 mg/m2). This surface protection was equally effective whether the adsorption involved the bimodal polymer surfactant or the purified high molecular weight fraction. The PEO tail mobility was investigated with electron paramagnetic resonance (EPR), and found to increase with an increase in polymer surface concentration. The comparatively slow motion of the PEO chains at low surface concentration indicated that not only the PPO block, but also the PEO blocks interacted hydrophobically with the PS surface. When the copolymer surface concentration was increased, the PEO tails were gradually being released, acquiring higher mobility as the surface became covered by the more strongly binding PPO blocks. Results obtained with F108 coated particles of different sizes showed that particle size had a significant effect on the fibrinogen uptake, with larger particles showing larger fibrinogen uptakes.  相似文献   

2.
M Amiji  K Park 《Biomaterials》1992,13(10):682-692
Fibrinogen adsorption and platelet adhesion on to dimethyldichlorosilane-treated glass and low-density polyethylene were examined. The surfaces were treated with poly(ethylene glycol) and poly(ethylene oxide)/poly(propylene oxide)/poly(ethylene oxide) triblock copolymers (Pluronics). Poly(ethylene glycol) could not prevent platelet adhesion and activation, even when the bulk concentration for adsorption was increased to 10 mg/ml. Pluronics containing 30 propylene oxide residues could not prevent platelet adhesion and activation, although the number of ethylene oxide residues varied up to 76. However, Pluronics containing 56 propylene oxide residues inhibited platelet adhesion and activation, even though the number of ethylene oxide residues was as small as 19. Fibrinogen adsorption on the Pluronic-coated surfaces was reduced by more than 95% compared to the adsorption on control surfaces. The ability of Pluronics to prevent platelet adhesion and activation was mainly dependent on the number of propylene oxide residues, rather than the number of ethylene oxide residues. The large number of propylene oxide residues was expected to result in tight interaction with hydrophobic dimethyldichlorosilane-treated glass and low-density polyethylene surfaces and thus the tight anchoring of Pluronics to the surfaces. The presence of 19 ethylene oxide residues in the hydrophilic poly(ethylene oxide) chains was sufficient to repel fibrinogen and platelets by the mechanism of steric repulsion.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号