首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
3.
4.
PURPOSE: To prospectively evaluate the effect of single- versus two-segment image reconstruction on image quality and diagnostic accuracy at 64-section multidetector computed tomographic (CT) coronary angiography by using conventional coronary angiography as the reference standard. MATERIALS AND METHODS: The study design was approved by a human research committee; patients gave informed consent. The study was HIPAA compliant. Forty consecutive patients (22 men, 18 women; mean age, 61 years +/- 8 [standard deviation]) underwent both 64-section multidetector CT coronary angiography and conventional angiography. All data sets were reconstructed by using single- and two-segment image reconstruction algorithms, with resulting temporal resolution of 82.5-165 msec. Two experienced observers independently evaluated image quality and signs of coronary artery disease. A five-level grading scheme was used to grade stenosis (0%, <50%, <70%, <99%, 100%) and image quality (1[unacceptable] to 5[excellent]). Interobserver correlation, Spearman correlation coefficients, and diagnostic accuracy were calculated. RESULTS: Six hundred coronary artery segments were visible on conventional angiograms, of which 560 (93.3%) were seen by using single-segment and 561 (93.5%) were seen by using two-segment image reconstruction (P=.35). Mean quality scores were not significantly different (P=.22) for single- (3.1 +/- 0.9) and two-segment (3.2 +/- 0.8) reconstruction. Significantly (P=.03) better image quality was observed for two-segment reconstruction only at heart rates of 80-82 beats per minute, at which temporal resolution was approximately 83 msec. For grading coronary artery stenosis, correlation was 0.64 for single- and 0.66 for two-segment reconstruction (P=.43). Significant stenosis (>50%) was detected on a per-segment basis with 77.1% sensitivity and 98.6% specificity by using single-segment and with 79.2% sensitivity and 99.1% specificity by using two-segment image reconstruction. CONCLUSION: At heart rates of more than 65 beats per minute, use of two-segment reconstruction improves image quality at multidetector CT coronary angiography but does not significantly affect overall diagnostic accuracy compared with single-segment reconstruction.  相似文献   

5.
Contrast-enhanced magnetic resonance angiography (MRA) is a noninvasive imaging alternative to digital subtraction angiography (DSA) for patients with carotid artery disease. In DSA, image quality can be improved by shifting the mask image if the patient has moved during angiography. This study investigated whether such image registration may also help to improve the image quality of carotid MRA. Data from 370 carotid MRA examinations of patients likely to have carotid artery disease were prospectively collected. The standard nonregistered MRAs were compared to automatically linear, affine and warp registered MRA by using three image quality parameters: the vessel detection probability (VDP) in maximum intensity projection (MIP) images, contrast-to-noise ratio (CNR) in MIP images, and contrast-to-noise ratio in three-dimensional image volumes. A body shift of less than 1 mm occurred in 96.2% of cases. Analysis of variance revealed no significant influence of image registration and body shift on image quality (p > 0.05). In conclusion, standard contrast-enhanced carotid MRA usually requires no image registration to improve image quality and is generally robust against any naturally occurring body shift. Electronic supplementary material  The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

6.
Clinical studies demonstrate a gain in diagnostic accuracy by employing combined PET/CT instead of separate CT and PET imaging. However, whole-body PET/CT examinations result in a comparatively high radiation burden to patients and thus require a proper justification and optimization to avoid repeated exposure or over-exposure of patients. This review article summarizes relevant data concerning radiation exposure of patients resulting from the different components of a combined PET/CT examination and presents different imaging strategies that can help to balance the diagnostic needs and the radiation protection requirements. In addition various dose reduction measures are discussed, some of which can be adopted from CT practice, while others mandate modifications to the existing hard- and software of PET/CT systems.  相似文献   

7.
《Radiography》2014,20(2):143-147
This article looks at the role of the radiographic images produced by diagnostic radiographers.An ethnographic study of the workplace culture in one diagnostic imaging department was undertaken using participant observation for four months and semi-structured interviews with ten key informants. One of the key themes; that of the radiographic image as a cultural artefact, is explored in this article.The radiographic image is a cultural artefact which radiographers are protective of and take ownership of. Radiographers are conscious of the quality of their images and the images are an important aspect of their work. Radiographers take criticism of their images personally. The radiographic image is a record of the interaction that occurs between the radiographer and the patient.The way in which radiographic images are viewed, used and judged is an important aspect of the role of diagnostic radiographer.  相似文献   

8.
9.
10.
Yeh BM 《Radiology》2006,241(3):633-634
Taillieu et al have shown that it is possible to noninvasively measure the placental blood flow, fractional volume of the maternal vascular placental compartment, and rate of transfer of contrast material between the maternal and fetal circulation in gravid mice through the use of dynamic contrast-enhanced MR imaging. Clearly, much work lies ahead before functional evaluation of the placenta becomes a clinical reality, but contrast-enhanced imaging shows promise for functional evaluation of placental disease.  相似文献   

11.
12.
13.
14.
Fidler A  Likar B 《Radiology》2007,245(1):299; author reply 299-299; author reply 300
  相似文献   

15.
16.
17.

Objective  

To assess if pulmonary CT angiography (CTA) can predict outcome in patients with pulmonary embolism (PE).  相似文献   

18.
19.

Objectives

To compare image noise, image quality and diagnostic accuracy of coronary CT angiography (cCTA) using a novel iterative reconstruction algorithm versus traditional filtered back projection (FBP) and to estimate the potential for radiation dose savings.

Methods

Sixty five consecutive patients (48 men; 59.3?±?7.7?years) prospectively underwent cCTA and coronary catheter angiography (CCA). Full radiation dose data, using all projections, were reconstructed with FBP. To simulate image acquisition at half the radiation dose, 50% of the projections were discarded from the raw data. The resulting half-dose data were reconstructed with sinogram-affirmed iterative reconstruction (SAFIRE). Full-dose FBP and half-dose iterative reconstructions were compared with regard to image noise and image quality, and their respective accuracy for stenosis detection was compared against CCA.

Results

Compared with full-dose FBP, half-dose iterative reconstructions showed significantly (p?=?0.001 ?C p?=?0.025) lower image noise and slightly higher image quality. Iterative reconstruction improved the accuracy of stenosis detection compared with FBP (per-patient: accuracy 96.9% vs. 93.8%, sensitivity 100% vs. 100%, specificity 94.6% vs. 89.2%, NPV 100% vs. 100%, PPV 93.3% vs. 87.5%).

Conclusions

Iterative reconstruction significantly reduces image noise without loss of diagnostic information and holds the potential for substantial radiation dose reduction from cCTA.  相似文献   

20.
OBJECTIVE: To assess the diagnostic value and to optimize image reconstruction for multislice spiral computed tomography (MSCT) of the sternum. MATERIALS AND METHODS: Forty patients underwent MSCT of the sternum using a standardized examination protocol (4x1 mm or 4x2.5 mm collimation; 120 kV, 120 mAseff). Axial images with an effective slice thickness of 1.25 mm or 3 mm and an increment of 0.8 mm or 1 mm were reconstructed. Coronal and sagittal reformations with a slice thickness between 2 mm or 3 mm and 5 mm and a slice distance ranging from 1 mm to 4 mm (overlap 1 mm) were calculated. In all patients, additional plain film radiographs (n=9) or clinical follow-up data were available. Image quality was assessed visually using a five-point grading scale. RESULTS: In all patients, the correct diagnosis was established using multiplanar reformats (MPR) exclusively. Best image quality for MPR was achieved using a slice thickness of 3 mm and a slice distance of 2 mm. Images acquired with a 4x1 mm collimation proved superior to images reconstructed from data obtained with a 4x2.5 mm collimation. CONCLUSION: MPR from MSCT data are a valuable tool for the diagnosis of sternal pathologies. For best image quality the thinnest possible collimation should be chosen.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号