首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.

Background

Question arises as to whether rigid fixation of ultra-short anatomic or ultra-short non-anatomic proximal loading uncemented femoral stem can be obtained without diaphyseal stem fixation. The purpose of this study is to compare the short-term clinical results, radiographic results, revision and survival rates, and complication rates of ultra-short anatomic versus ultra-short non-anatomic uncemented femoral stems.

Methods

This study consisted of 50 patients (56 hips) in the ultra-short anatomic uncemented stem group (mean age 61.4 ± 14.7 years) and 50 patients (56 hips) in the ultra-short non-anatomic uncemented stem group (mean age 59.5 ± 15.2 years). The mean follow-up was 3.4 years (range 3-4) in the ultra-short anatomic stem group and 3.5 years (range 3-4) in the ultra-short non-anatomic stem group.

Results

At the final follow-up, the mean Harris hip scores (92 vs 93 points), Western Ontario and McMaster Universities Osteoarthritis scores (16 vs 15 points), University of California at Los Angeles activity scores (6.5 vs 6.8 points), the incidence of thigh pain (0% vs 4%), revision rates (0% vs 4%), aseptic loosening rate (0% vs 2%), and complication rates (2% vs 4%) were not significantly different between 2 groups.

Conclusion

Both ultra-short anatomic and ultra-short non-anatomic proximal loading uncemented femoral stems obtained rigid fixation without diaphyseal stem fixation in the short-term follow-up. This finding suggests that an ultra-short anatomic uncemented femoral stem can be replaced with an ultra-short non-anatomic uncemented stem to reduce inventory of the femoral stems, and consequently reduce manufacturing and delivery cost of these femoral stems.  相似文献   

2.
BackgroundThere is a paucity of studies longer than 30 years to determine clinical and radiographic results of retained cementless anatomic stem. The purpose of this study is to determine the long-term (up to 34 years) survival rate of the retained cementless anatomic femoral stem in patients <50 years of age.MethodsIsolated cup revision was performed with retaining primary cementless anatomic femoral stem in 206 patients (149 men and 57 women). Clinical and radiographic results were monitored at each follow-up. At the latest follow-up, computed tomography scans were carried out in all hips to determine the prevalence of osteolysis. The mean follow-up of the retained femoral stem was 30.3 years (range 27-34). The mean follow-up of the revised cup was 25.5 years (range 22-29).ResultsThe mean Harris Hip Score was 91 ± 7.8 points (range 71-100) and the mean Western Ontario and McMaster Universities Osteoarthritis score was 16 ± 7 points (range 7-34) at the final follow-up. The mean University of California, Los Angeles activity score was 7 ± 4 points (range 5-10) at the final follow-up. The overall survival rate of retained cementless femoral stems was 98.9% (95% confidence interval 91-100) at 30.3 years. The survival rate of the revised cup was 93% (95% confidence interval 89-98) at 25.5 years.ConclusionThe rate of aseptic loosening of already osseointegrated femoral stem remains low with ceramic-on-ceramic bearing in young active patients.  相似文献   

3.
BackgroundThere are no reported results for more than 20 years of a pure proximal-loading anatomic cementless femoral stem without diaphyseal stem fixation. The purpose of this study was to evaluate the long-term (minimum 20 years) clinical results, bone remodeling, revision rate, and survivorship of these implants in patients aged less than 60 years.MethodsWe included 523 patients (657 hips), including 319 men and 204 women. The mean body mass index was 26.7 (range, 23-29 kg/m2). The mean age of patients at index surgery was 55 years (range, 20-59 years). The Harris Hip Score, the Western Ontario and McMaster Universities Osteoarthritis Index, and the University of California, Los Angeles activity score were recorded preoperatively and at each follow-up. Mean follow-up was 23.5 years (range, 20-27 years).ResultsThe Harris Hip Score at the final follow-up was a mean 93 points (range, 70-100 points). The Western Ontario and McMaster Universities Osteoarthritis Index and University of California, Los Angeles activity scores at the final follow-up were 16 and 7.6 points, respectively. Five femoral components (0.8%) and 13 acetabular components (2.0%) were revised. All cases in the current series had grade 2 stress shielding; no hips had grade 3 or 4 stress shielding. Kaplan-Meier survivorship of the implants at 23.5 years was 98.0% (95% confidence interval 92%-100%) for the acetabular component and 99.2% (95% confidence interval 93%-100%) for the femoral component.ConclusionA pure proximal-loading metaphyseal-fitting anatomic cementless stem with alumina-on-alumina ceramic bearing couples functioned well, with no osteolysis or mild stress-shielding at an average 23.5-year follow-up.  相似文献   

4.
BackgroundThe rate of failure of cemented and cementless total hip arthroplasty (THA) in younger patients is higher than that in elderly patients. The purpose of this study is to document the long-term clinical results of THA with the so-called third-generation cementing and the results of second-generation cementless THA in patients <50 years of age.MethodsThis study included 106 patients who had had bilateral THA with a cemented stem in one hip and a cementless stem in the other. There were 78 men and 28 women. Their mean age was 47 years (range, 21-49). The average follow-up duration was 31 years (range, 30-32.5).ResultsThere were similar mean Harris Hip Scores (90 versus 91 points) between the groups at the final follow-up. Forty-six acetabular components (43%) in the cemented group and 48 acetabular components (45%) in the cementless group were revised. Five femoral components (5%) in the cemented group and 4 femoral components (4%) in the cementless group were revised. Survivorship of the acetabular component at 30.8 years was similar in both groups (57% in the cemented group versus 55% in the cementless group). Survivorship of the femoral component at 30.8 years was also similar in both groups (95% in the cemented group versus 96% in the cementless group).ConclusionLong-term fixation of the cemented or cementless femoral stem was outstanding. There was a high rate of the acetabular component revision due to conventional polyethylene wear and periacetabular osteolysis in both hybrid and fully cementless THA groups.  相似文献   

5.
《The Journal of arthroplasty》2022,37(11):2225-2232
BackgroundThe purpose of this long-term (up to 17 years) follow-up study was to determine: (1) clinical results and evidence of clicking or squeaking sounds; (2) radiographic results, including rates of osseointegration, bone remodeling, and osteolysis; (3) rates of complications including thigh pain, periprosthetic fracture, and ceramic fracture; (4) rates of revision; and (5) survival rates of implants in patients younger than 30 years.MethodsWe analyzed the results of 240 consecutive primary total hip arthroplasty in 180 patients (118 men and 62 women who had a mean age of 27 years (range, 21 to 30 years)). The mean follow-up was 16 years (range, 14 to 17 years).ResultsMean Harris hip score, Western Ontario and McMaster Universities score, and University of California, Los Angeles activity score were 93 points, 18 points, and 7 points, respectively, at final follow-up. Radiographically, all of the acetabular components and all but two femoral components were well-fixed at the final follow-up. No hip had osteolysis or exhibited Grade 3 stress shielding. All but two patients had no groin or thigh pain. No hip had a periprosthetic or ceramic fracture. Eight hips (3%) exhibited squeaking sounds. Two acetabular components and two femoral stems were revised. The survival of the acetabular and femoral component was 99.2% (95% confidence interval, 94 to 100%).ConclusionThe results of the present long-term study of ultra-short anatomic cementless femoral stems suggest excellent clinical and radiographic results in patients younger than 30 years.  相似文献   

6.
Subtrochanteric fractures of the femur below an arthritic hip are uncommon and challenging to orthopedic surgeons. Most of these fractures occur in elderly patients with advanced osteoporosis. The treatment choices consist of treatment of the fracture and the above hip joint versus treatment of the fracture alone. This study evaluates the clinical and radiological outcomes of arthroplasties performed to treat both conditions in a single surgery with the use of a cementless modular revision stem. Twelve subtrochanteric femoral fractures of 12 patients (9 women, 3 men) with a mean age of 76.4 years (range, 62-88 years) were treated with cementless modular revision stems. Total hip arthroplasty was performed with cementless femoral and acetabular component fixation. All hips received the same femoral and acetabular implants. All patients had comorbidities and the average American Society of Anesthesiologists score was 2.3 (range, 1-3). Ten of the 12 hips (83%) required an assistance device for ambulation before the trauma. There were 2 Dorr Type A (17%), 3 Dorr type B (25%), and 7 Dorr type C (58%) femora. The mean postoperative Harris Hip Score was 83 (range, 72-92) with a mean follow-up of 4.3 years (range, 2-7 years). At final follow-up, 9 hips (75%) were ambulatory without support (P=.016). Ten hips (83%) were able to both ambulate and walk up and down stairs. Two hips (17%) were able to ambulate but could not climb and descend stairs. Union was achieved in all femora at an average of 22.3 weeks (range, 16-32 weeks). Radiographic findings demonstrated stable ingrowth of the femoral prosthesis with no evidence of subsidence in 11 hips (92%). The average Engh score for all femora was 20.2 (range, 10-26). There was no relationship between the bone morphology (Dorr type) of the femoral medullary canal and the bone ingrowth scores of Engh (P=.639).  相似文献   

7.
BackgroundThe aim of this study is to assess the long-term outcomes of this specific stem in patients younger than 50 years old, with regard to clinical and radiographic outcomes, survivorship, and complication rate.MethodsTwo hundred thirty-nine consecutive series of patients (324 hips) who were younger than 50 years old at the time of surgery were enrolled in the study. Osteonecrosis (50%) and dysplastic hip (34%) were most common diagnoses. Patients were informed to use crutches or walker for 4 weeks to protect the femoral component against rotational stress. The mean follow-up was 15.6 years (range 14-17).ResultsAt the latest follow-up, the mean Harris Hip Score, Western Ontario and McMaster Universities Osteoarthritis Index score, and University of California, Los Angeles activity score were 93 points, 13 points, and 7 points, respectively. Three patients (1.3%) had moderate thigh pain. All of the acetabular components and 321 (99%) femoral stems were solidly fixed at the time of the latest follow-up. Three stems (0.9%) were revised for aseptic loosening. Two hips (0.6%) had a dislocation and 2 hips (0.6%) had a periprosthetic fracture. Ceramic fracture or osteolysis was not found in any hip at the time of the final follow-up. Survival rate of the femoral component was 99.1% (95% confidence interval 94-100) and that of the acetabular component was 100% (95% confidence interval 94-100) at 15.6 years.ConclusionIn this series, THA using an ultra-short metaphyseal-fitting anatomic cementless femoral stem provided excellent long-term clinical and radiographic results in patients younger than 50 years old. Furthermore, our initial theoretical concerns about early aseptic loosening due to the absence of distal stem fixation were not justified.  相似文献   

8.
The objective of this retrospective study was to evaluate our results with one-stage revision using cementless femoral stem for infected hip arthroplasties. Twenty-four patients were included in the study. The acetabular component was cemented in 9 cases. In 2 patients a structured bone allograft was necessary to fill an acetabular defect. After a mean follow-up of 44.6 months, 23 patients showed no signs of infection (95.8%), the mean functional response according to the Merle d’Aubigné scale was 13.8 and the mean Harris Hip Score was 65.4. One-stage revision hip arthroplasty using cementless femoral stem was associated with a high success rate.  相似文献   

9.
BackgroundThe purpose of this study is to compare the long-term clinical and radiographic results, survival rates, and complication rates of an ultra-short vs a conventional length cementless anatomic femoral stem.MethodsWe reviewed 759 patients (858 hips) (mean age, 56.3 ± 12.9 y) who had an ultra-short cementless anatomic stem and 759 patients (858 hips) (mean age, 54.8 ± 12.3 y) who had a conventional length cementless anatomic stem. The mean follow-up was 16.5 years (range 14-17) in the ultra-short stem group and 17.5 years (range 17-20) in the conventional stem group.ResultsAt the latest follow-up, there were no significant differences between the 2 groups in terms of the Harris Hip Scores (92 ± 6 vs 91 ± 7 points, P = .173), Western Ontario and McMaster Universities Osteoarthritis scores (12 ± 8 vs 13 ± 7 points, P = .972), University of California Los Angeles activity scores (7.6 vs 7.8 points, P = .841), patient satisfaction scores (7.7 ± 2.3 vs 7.5 ± 2.5 points, P = .981), and survival rates (97.6% vs 96.6%). However, incidence of thigh pain (P = .031) and stress shielding (P = .001) was significantly higher in the conventional length stem group than in the ultra-short anatomic stem group. Complication rates were similar (1.8% vs 2.7%) between the 2 groups.ConclusionAlthough an ultra-short cementless anatomic femoral stem confers equivalent clinical and radiographic outcomes, survival rates, and complication rates to conventional length cementless anatomic stem, the incidence of thigh pain and stress shielding was significantly lower in the ultra-short cementless anatomic stem.Level of EvidenceTherapeutic Level I.  相似文献   

10.
BackgroundThe American Academy of Orthopaedic Surgeons guidelines report moderate evidence for cementing femoral stems for hip fractures, mainly derived from hemiarthroplasty literature. This is the first large, nonregistry study examining the influence of femoral fixation, implant type, patient characteristics, and radiographic factors on outcomes after total hip arthroplasty (THA) for acute femoral neck fractures.MethodsA multicenter retrospective study was performed of 709 THA cases (199 cemented, 510 cementless) for femoral neck fractures from 2006 to 2020 at three large academic institutions. Demographics, perioperative characteristics, and radiographs were reviewed. Kaplan-Meier survivorship curves were generated for multiple outcomes. Univariate and multivariate analyses were performed with P ≤ .05 denoting significance.ResultsCementless stems had a higher all-cause aseptic femoral revision rate (5.1 versus 0.5%, P = .002) and periprosthetic femoral fracture rate (4.3 versus 0%, P = .001). Each successive Dorr type had a higher fracture rate with cementless implants: 2.3%, 3.7%, and 15.9% in Dorr A, B, and C, respectively (P < .001). Logistic regression analyses confirmed that cementless stems (P = .02) and Dorr C bone (P = .001) are associated with periprosthetic fractures; collared implants and prophylactic cables did not protect against fractures. There was no difference in rates of dislocation, septic revision, or mortality between groups.ConclusionCementless stems during THA for femoral neck fractures have a higher aseptic femoral revision rate, specifically for periprosthetic fractures. Dorr C bone was particularly prone with an alarmingly high fracture rate. All fractures occurred in cementless cases, suggesting that cemented stems may minimize this complication.Level of EvidenceIII.  相似文献   

11.
BackgroundRevision of failed total hip arthroplasty (THA) presents great challenge to any orthopaedic surgeon especially in the presence of acetabular defects where the main goal is to achieve durable fixation of prosthetic components to bone which is the key to successful revision surgery.MethodsSeventeen patients (17 hips) with mean age of 52 (40–61) years had revision surgery for aseptic failure of Furlong hydroxyapatite-ceramic-coated (HAC) prosthesis using cementless jumbo cups. Patients were reviewed clinically and radiographically with mean follow-up of 3.5 years (2–6). No patient was lost to follow up.ResultsAll revised acetabular components showed polyethylene wear, severe metallosis, with acetabular defects IIB (4/17), and IIIA (13/17) according to Paprosky classification. The femoral component was well fixed in all cases but one patient had stem revision for femoral fracture mal-union. There was one early post-operative infection; there was no postoperative dislocation, sciatic nerve injury, periprosthetic fracture or deep venous thrombosis. At last follow-up, no progressive radiolucencies or acetabular migration was identified. The mean Harris hip score improved from 42 (24–59) pre-operatively to 85 (72–92).ConclusionGood clinical results and radiographic stability were obtained at short term follow up after acetabular revision using cementless jumbo cups, which justify its use in revision surgery even in the face of major acetabular defects. Furlong HAC femoral component gives excellent long-term survival in young and active patients with a survival rate of 94% at 18.6 years.  相似文献   

12.
This study reviewed the results of a cementless anatomical femoral component to give immediate post-operative stability, and with a narrow distal section in order not to contact the femoral cortex in the diaphysis, ensuring exclusively metaphyseal loading. A total of 471 patients (601 hips) who had a total hip replacement between March 1995 and February 2002 were included in the study. There were 297 men and 174 women. The mean age at the time of operation was 52.7 years (28 to 63). Clinical and radiological evaluation were performed at each follow-up. Bone densitometry was carried out on all patients two weeks after operation and at the final follow-up examination. The mean follow-up was 8.8 years (5 to 12). The mean pre-operative Harris hip score was 41 points (16 to 54), which improved to a mean of 96 (68 to 100) at the final follow-up. No patient complained of thigh pain at any stage. No acetabular or femoral osteolysis was observed and no hip required revision for aseptic loosening of either component. Deep infection occurred in two hips (0.3%) which required revision. One hip (0.2%) required revision of the acetabular component for recurrent dislocation. Bone mineral densitometry revealed a minimal bone loss in the proximal femur. This cementless anatomical femoral component with metaphyseal loading but without distal fixation produced satisfactory fixation and encourages proximal femoral loading.  相似文献   

13.
BACKGROUND: Second-generation cementless femoral components were designed to provide more reliable ingrowth and to limit distal osteolysis by incorporating circumferential proximal ingrowth surfaces. We examined the eight to eleven-year results of total hip arthroplasty with a cementless, anatomically designed femoral component and a cementless hemispheric acetabular component. METHODS: Ninety-two consecutive primary total hip arthroplasties with implantation of a femoral component with a circumferential proximal porous coating (Anatomic Hip) and a cementless hemispheric porous-coated acetabular component (Harris-Galante II) were performed in eighty-five patients. These patients were prospectively followed clinically and radiographically. Six patients (seven hips) died and five patients (seven hips) were lost to follow-up, leaving seventy-four patients (seventy-eight hips) who had been followed for a mean of ten years (range, eight to eleven years). The mean age at the time of the arthroplasty was fifty-two years. RESULTS: The mean preoperative Harris hip score of 51 points improved to 94 points at the time of final follow-up; 86% of the hips had a good or excellent result. Thigh pain was reported as mild to severe after seven hip arthroplasties. No femoral component was revised for any reason, and none were loose radiographically at the time of the last follow-up. Two hips underwent acetabular revision (one because of dislocation and one because of loosening). Kaplan-Meier survivorship analysis was performed with revision or loosening of any component as the end point. The ten-year survival rate was 96.4% +/- 2.1% for the total hip prosthesis, 100% for the femoral component, and 96.4% +/- 2.1% for the acetabular component. Radiolucencies adjacent to the nonporous portion of the femoral component were seen in sixty-eight (93%) of the -seventy-three hips with complete radiographic follow-up. Femoral osteolysis proximal to the lesser trochanter was noted in four hips (5%). No osteolysis was identified distal to the lesser trochanter. Periacetabular osteolysis was identified in twelve hips (16%). Five patients underwent exchange of the acetabular liner because of polyethylene wear. CONCLUSIONS: This second-generation cementless, anatomically designed femoral component provided excellent clinical and radiographic results with a 100% survival rate at ten years. The circumferential porous coating of this implant improved ingrowth and prevented distal osteolysis at a mean of ten years after the arthroplasty.  相似文献   

14.
The optimal technique for acetabular revision surgery in the face of major bone stock deficiency remains controversial. One subset of these problem cases consists of hips that are amenable to reconstruction using a large, hemispherical cementless acetabular component, the so-called jumbo acetabular component. We report the intermediate-term experience of 24 hips in 24 patients who underwent an uncemented acetabular revision using a hemispherical acetabular component of > or = 66 mm diameter. In 16 hips, the femoral component was replaced as well. Of the 18 hips in patients alive after 5 years, 15 were assessed at a mean follow-up of 7.0 years (range, 5.0-10.3 years). The mean final Harris Hip Score was 86 points (range, 45-100 points). No acetabular component had been revised, and none were loose radiographically. In this difficult group, a bimodal distribution resulted. The complication rate was high. In those without infection, the results were excellent.  相似文献   

15.
This study aimed to report the outcome of total hip arthroplasty (THA) with a modular femoral component in patients younger than fifty years with osteonecrosis of femoral head. Sixty-four osteonecrotic hips in fifty-five patients were available for clinical and radiographic analyses at minimum follow-up of fifteen-years. The mean Harris hip score improved from 36 points preoperatively to 92.7 points at final follow-up. Sixty-two (95.3%) hips demonstrated stable bone ingrowth. No hips showed loosening or required revision for aseptic loosening. Survivorship with an end point of stem revision for any reason was 93.8% and for aseptic loosening was 100% at 16.8 years. We believe that cementless THA with a modular stem is a promising procedure for young and active patients with osteonecrosis of the femoral head.  相似文献   

16.
The 10- to-13 year performance of 307 Mallory Head cementless tapered total hip replacements in 283 patients was assessed. Eighty-five percent of patients had a diagnosis of osteoarthritis. Fifty-one percent of patients were women. The mean patient age was 64 +/- 10 years. The Hex Loc cementless acetabular component and titanium alloy femoral heads were used in each patient. At final followup, 37 (13%) patients died, 32 (10%) had revision surgery, and two (1%) were lost to followup. No femoral stem was revised for aseptic loosening, but one was revised because of sepsis and one was revised because of a periprosthetic fracture. Wear, osteolysis, and loosening were problems with the Hex Loc cementless acetabular components and 31 (10%) acetabular components required revision because of these mechanisms. The mean Harris hip score at final followup of the remaining patients was 87 +/- 14 points. Three percent of these patients had thigh pain. Radiographic assessment revealed that no femoral stem or acetabular socket was definitely or probably loose. Three-dimensional wear assessment using the Devane technique was 0.35 mm per year. The Mallory Head cementless, tapered femoral component performed well in the patients in the current study, but unfortunately, the clinical results were compromised by the use of a suboptimal cementless acetabular component, the use of polyethylene that was gamma-irradiated in air, and by the use of titanium alloy femoral heads. Future developments obviously will be in the areas of better acetabular component design, alternate polyethylene sterilization methods, and enhancements of the femoral stem in terms of offset choices, neck design, and perhaps ingrowth surface.  相似文献   

17.
Yang J  Kang PD  Shen B  Zhou ZK  Pei FX 《中华外科杂志》2010,48(14):1055-1059
目的 回顾性分析股骨髓内同种异体颗粒骨打压植骨结合非骨水泥长柄假体在髋关节翻修术中股骨侧骨缺损修复应用的近期临床效果.方法 2003年7月至2009年6月对27例股骨侧骨缺损患者采用同种异体颗粒骨打压植骨,其中男性15例,女性12例,年龄47~78岁,平均67岁.失败原因:骨溶解、无菌性松动20例,全髋关节置换术后假体周围感染二期翻修7例.按Paprosky分型标准,Ⅱ型骨缺损3例,Ⅲ型骨缺损2l例,Ⅳ型骨缺损3例.术中均采用同种异体颗粒骨打压植骨、非骨水泥翻修柄植入.定期随访复查,包括临床、影像学评估,观察假体有无松动、下沉,植入骨活化替代情况以及假体周围骨折等并发症.Harris评分术前平均43分(37~62分).结果 23例患者获得随访,随访时间3~47个月,平均26.4个月.术后末次随访时.Harris评分平均83分(67~97分).术中2例发生股骨大转子骨折,无一例发生术后假体周围骨折等并发症.1例术后发生关节脱位,1例发生深静脉血栓,1例术后2周发生急性感染,经扩创、置管冲洗、抗感染治疗成功保留假体;发生异位骨化1例,Brooker Ⅰ级.影像学所有患者股骨柄中置,无内翻或外翻,随访期内无一例发生股骨柄移位(内翻或外翻角度变化>3°).23例患者显示至少Ⅰ区股骨髓内移植骨与周围骨或与股骨柄整合.4例发生股骨柄假体下沉,平均下沉3.3 mm(2~6 mm).结论 股骨侧翻修中,良好的股骨髓内同种异体颗粒骨打压植骨结合合适的非骨水泥延长柄股骨假体,可以修复关节置换术后各种原因所导致股骨骨缺损、重建股骨完整性,具有很好的近期临床疗效.但中远期临床效果尚待进一步观察.  相似文献   

18.
We performed 114 consecutive primary total hip arthroplasties with a cementless expansion acetabular component in 101 patients for advanced osteonecrosis of the femoral head. The mean age of the patients at surgery was 51 years (36 to 62) and the mean length of follow-up was 110 months (84 to 129). The mean pre-operative Harris hip score of 47 points improved to 93 points at final follow-up. The polyethylene liner was exchanged in two hips during this period and one broken acetabular component was revised. The mean linear wear rate of polyethylene was 0.07 mm/year and peri-acetabular osteolysis was seen in two hips (1.9%). Kaplan-Meier analysis indicated that the survival of the acetabular component without revision was 97.8% (95% confidence interval 0.956 to 1.000) at ten years. Our study has shown that the results of THA with a cementless expansion acetabular component and an alumina-polyethylene bearing surface are good.  相似文献   

19.
Park YS  Park SJ  Lim SJ 《Orthopedics》2010,33(11):796
We analyzed the long-term results of a single-surgeon series of 102 cementless total hip arthroplasties (THAs) performed using a sandwich-type alumina ceramic bearing. The prostheses involved a porous-coated acetabular socket, a polyethylene-alumina composite liner, a 28-mm alumina head, and a grit-blasted titanium-alloy stem. Mean patient age at the time of THA was 39 years (range, 18-66 years), and 76% of the patients were younger than 50 years. All procedures were performed with use of the same surgical technique and the same implant at a single center. Mean follow-up was 115 months (range, 84-133 months). When failure was defined as revision of either the acetabular or the femoral component for any reason, Kaplan-Meier survival probability at 10 years was 95.3% (95% confidence interval, 89.5%-100%). Mean Harris Hip Score improved from 47 points (range, 16-70 points) preoperatively to 95 points (range, 85-100 points) at final follow-up. No radiographically detectable osteolysis around the acetabular or femoral component was observed in any hip. No patient reported squeaking in the operated hip. During the follow-up period, 3 hips (3%) required revision surgery; 2 underwent acetabular revision because of a ceramic liner fracture and 1 underwent revision for early loosening of the acetabular cup. Ten-year results of cementless THA with a sandwich-type alumina ceramic bearing were encouraging, and no great increase in ceramic failure rate was observed, which contrasts with the findings of previously reported short-term follow-up studies.  相似文献   

20.
LH Chung  PK Wu  CF Chen  WM Chen  TH Chen  CL Liu 《Orthopedics》2012,35(7):e1017-e1021
Between January 1999 and August 2008, ninety-six femoral revisions were performed with extensively porous-coated stems in Paprosky type III femoral defects (89 type IIIA and 7 type IIIB defects). Seven type IIIB defects with a mean canal of 16.5 mm were observed; 6 defects achieved stable bone ingrowth and 1 achieved stable fibrous condition. Average postoperative Harris Hip Score was 92.3±8 (range, 77-100), and all scores improved postoperatively. At a mean follow-up of 65.7 months, 92 stems achieved bone ingrowth, and 1 stem (type IIIB) achieved a stable fibrous condition. Three patients died from causes unrelated to the surgery during follow-up. The most frequent diagnosis for revision of the femoral component was loosening of the cementless stem (53 patients; 55.2%), followed by status after a Girdlestone procedure (21 patients; 21.8%), after total hip arthroplasty with acetabular wear (10 patients; 10.4%), loosening of the cemented stem (7 patients; 7.3%), and periprosthetic fracture (5 patients; 5.2%). The authors performed 65 total hip arthroplasty revisions, 23 femoral component revisions, and 8 revisions of femoral components with cemented liners in patients with well-fixed acetabular shells. Extensively porous-coated stems in femoral revision for Paprosky type III femoral defects provided good mid-term durability.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号