首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
BackgroundSagittal pelvic dynamics mainly consist of the pelvis rotating anteriorly or posteriorly while the hips flexes, and this affects the femoroacetabular or THA configuration. Thus far, it is unknown how the acetabular cup of the THA in the individual patient reorients with changing sagittal pelvic dynamics.Questions/purposesThe aim of this study was to validate a method that establishes the three-dimensional (3-D) acetabular cup orientation with changing sagittal pelvic dynamics and describe these changes during functional pelvic dynamics.MethodsA novel trigonometric mathematical model, which was incorporated into an easy-to-use tool, was tested. The model connected sagittal tilt, transverse version, and coronal inclination of the acetabular cup during sagittal pelvic tilt. Furthermore, the effect of sagittal pelvic tilt on the 3-D reorientation of acetabular cups was simulated for cups with different initial positions. Twelve pelvic CT images of patients who underwent THA were taken and rotated around the hip axis to different degrees of anterior and posterior sagittal pelvic tilt (± 30°) to simulate functional pelvic tilt in various body positions. For each simulated pelvic tilt, the transverse version and coronal inclination of the cup were manually measured and compared with those measured in a mathematical model in which the 3-D cup positions were calculated. Next, this model was applied to different acetabular cup positions to simulate the effect of sagittal pelvic dynamics on the 3-D orientation of the acetabular cup in the coronal and transverse plane. After pelvic tilt was applied, the intraclass correlation coefficients of 108 measured and calculated coronal and transverse cup orientation angles were 0.963 and 0.990, respectively, validating the clinical use of the mathematical model.ResultsThe changes in 3-D acetabular cup orientation by functional pelvic tilt differed substantially between cups with different initial positions; the change in transverse version was much more pronounced in cups with low coronal inclination (from 50° to -29°) during functional pelvic tilt than in cups with a normal coronal inclination (from 39° to -11°) or high coronal inclination (from 31° to 2°). However, changes in coronal inclination were more pronounced in acetabular cups with high transverse version.ConclusionUsing a simple algorithm to determine the dynamic 3-D reorientation of the acetabular cup during functional sagittal pelvic tilt, we demonstrated that the 3-D effect of functional pelvic tilt is specific to the initial acetabular cup orientation and thus per THA patient.Clinical RelevanceFuture studies concerning THA (in)stability should not only include the initial acetabular cup orientation, but also they need to incorporate the effect of sagittal pelvic dynamics on the individual 3-D acetabular cup orientation. Clinicians can also use the developed tool, www.3d-hip.com, to calculate the acetabular cup’s orientation in other instances, such as for patients with spinopelvic imbalance.  相似文献   

2.
BackgroundThis prospective cohort study aimed to characterize how spinopelvic characteristics change post-total hip arthroplasty (THA) and determine how patient-reported outcome measures are associated with 1) individual spinopelvic mobility and 2) functional sagittal cup orientation post-THA.MethodsOne hundred consecutive patients who received unilateral THAs for end-stage hip osteoarthritis, without spinal pathology were studied. Preoperatively and postoperatively, patients underwent clinical and radiographic evaluations. Patient-reported outcomes were collected using the hip disability and osteoarthritis outcome score - physical function shortform (HOOS-PS). Radiographic parameters measured from standing and relaxed-seated radiographs, included the lumbar lordosis angle, pelvic tilt, pelvic femoral angle and cup orientation in the coronal (inclination/anteversion) and sagittal (anteinclination) planes. Spinopelvic mobility was characterized (ΔPT: “stiff” [<10°], “normal” [10°-30°], and “hypermobile” [>30°]).ResultsPreoperative spinopelvic characteristics were not associated with HOOS-PS. Post-THA, the spinopelvic characteristics changed, with less patients having spinopelvic hypermobility (7%) compared with preop (14%). Postoperatively, patients with spinopelvic hypermobility showed significantly worse HOOS-PS scores (21 ± 17 vs 21 ± 22 vs 41 ± 23; ANOVA P = .037). Sagittal but not coronal cup orientation was associated with postoperative spinopelvic characteristics. Cup anteinclination was less in the patients with postoperative spinopelvic hypermobility (27 ± 7° vs 36 ± 8° vs 36 ± 10°; ANOVA: P = .035).ConclusionWe hypothesize that spinopelvic hypermobility is secondary to impingement and reduced hip flexion; to achieve a seated position, impinging hips require more posterior pelvic tilt. Patients with spinopelvic hypermobility are likely impinging secondary to the low cup anteinclination (sagittal malorientation despite optimum coronal orientation) and thus have lower HOOS-PS compared. Sagittal assessments are thus important to adequately study hip mechanics.Level of EvidenceLevel II, diagnostic study.  相似文献   

3.

Background

Changes in spinal alignment and pelvic tilt alter acetabular orientation in predictable ways, which may have implications on stability of total hip arthroplasty (THA). Patients with sagittal spinal deformity represent a subset of patients who may be at particularly high risk of THA instability because of postural compensation for abnormal spinal alignment.

Methods

Using standing stereoradiography, we evaluated the spinopelvic parameters, acetabular cup anteversion, and inclination of 139 THAs in 107 patients with sagittal spinal deformity. Standing images were compared with supine pelvic radiographs to evaluate dynamic changes in acetabular cup position. Dislocation and revision rates were procured through retrospective chart review. The spinal parameters and acetabular cup positions among dislocators were compared with those who did not dislocate.

Results

The rate of THA dislocation in this cohort was 8.0%, with a revision rate of 5.8% for instability. Patients who sustained dislocations had significantly higher spinopelvic tilt, T1-pelvic angle, and mismatch of lumbar lordosis and pelvic incidence. Among all patients, 78% had safe anteversion while supine, which decreased significantly to 58% when standing due to increases in spinopelvic tilt. Among dislocating THA, 80% had safe anteversion, 80% had safe inclination, and 60% had both parameters within the safe zone.

Conclusion

In this cohort, patients with THA and concomitant spinal deformity have a particularly high rate of THA instability despite having an acetabular cup position traditionally thought of as within acceptable alignment. This dislocation risk may be driven by the degree of spinal deformity and by spinopelvic compensation. Surgeons should anticipate potential instability after hip arthroplasty and adjust their surgical plan accordingly.  相似文献   

4.
BackgroundExcessive standing posterior pelvic tilt (PT), lumbar spine stiffness, low pelvic incidence (PI), and severe sagittal spinal deformity (SSD) have been linked to increased dislocation rates. We aimed to determine the prevalence of these 4 parameters in a cohort of unstable total hip arthroplasty (THA) patients and compare these to a large representative control population of primary THA patients.MethodsForty-eight patients with instability following primary THA were compared to a control cohort of 9414 THA patients. Lateral X-rays in standing and flexed-seated positions were used to assess PT and lumbar lordosis (LL). Computed tomography scans were used to measure PI and acetabular cup orientation. Thresholds for “at risk” spinopelvic parameters were standing posterior PT ≤ −15°, lumbar flexion (LLstand–LLseated) ≤ 20°, PI ≤ 41°, PI ≥ 70°, and SSD (PI–LLstand mismatch ≥ 20°).ResultsThere were significant differences in mean spinopelvic parameters between the dislocating and control cohorts (P < .001). There were no differences in mean PI (58° versus 56°, respectively, P = .29) or prevalence of high and low PI between groups. 67% of the dislocating patients had one or more significant risk factors, compared to only 11% of the control. A total of 71% of the dislocating patients had cup orientations within the traditional safe zone.ConclusionExcessive standing posterior PT, low lumbar flexion, and a severe SSD are more prevalent in unstable THAs. Pre-op screening for these parameters combined with appropriate planning and implant selection may help identify at risk patients and reduce the prevalence of dislocation.  相似文献   

5.
BackgroundThe sitting position has become the most common posture in today’s workplace. In relation to this position, kinematic analysis of the lumbar spine is helpful in understanding the causes of low back pain and its prevention.MethodsIn this study, we investigated the relationship between sagittal lumbar alignment and pelvic alignment in the standing and sitting positions for 50 healthy adults. Lumbar lordotic angle (LLA), sacral slope (SS), pelvic tilt (PT), and pelvic incidence (PI) were measured on lateral lumbar spine standing and sitting radiographs.ResultsRegarding changes from the standing to sitting positions, averageLLA, SS, and PT were ?16.6° (?49.8 %), ?18.7° (?50.3 %), and 18.3° (284.8 %), respectively (P < 0.01). In the sitting position, lumbar lordosis was reduced and pelvic rotation became posterior.ConclusionsThis study showed that LLA decreased by approximately 50 % and PT increased by approximately 25 % in the sitting position compared with the standing position. No significant gender differences were observed for LLA, SS, and PT in the standing position. In the sitting position, however, LLA and SS were markedly larger for women.  相似文献   

6.
《The Journal of arthroplasty》2020,35(9):2507-2512
BackgroundCup orientation has been shown to influence the postoperative risk of impingement and dislocation following total hip arthroplasty (THA) and may change over time due to changes in pelvic tilt that occur with aging. The purpose of this study is to determine if there is a significant change in acetabular cup inclination and anteversion over a 10-year period following THA.MethodsA retrospective, multisurgeon, single-center cohort study was conducted of 46 patients that underwent THA between 1995 and 2002. A total of 46 patients were included, with a median age at surgery of 56 years, and a median time between initial postoperative radiograph and the most recent one being 13.5 years (minimum 10 years). Cup orientation was measured from postoperative and follow-up supine anterior-posterior pelvic radiographs. Using a validated software, inclination and anteversion were calculated at each interval and the change in cup anteversion and inclination angle was determined. Furthermore, the difference in the sacro-femoral-pubic angle was measured, reflecting the difference in pelvic tilt between intervals.ResultsNo significant difference was detected between measurements taken from initial postoperative radiograph and measurements a minimum of 10 years later (P > .45), with the median (interquartile range) change in anteversion, inclination, and sacro-femoral-pubic being 0° (−1° to 3°), 1° (−3° to 2°), and 0° (−2° to 3°), respectively.ConclusionOur study found no significant change in functional cup orientation a minimum of 10 years after THA. No shifts in functional cup orientation as a result of altering spinopelvic alignment seemed to be present over a 10-year period.  相似文献   

7.

Background

Sitting radiographs have been used as a pre-operative tool to plan patient-specific total hip arthroplasty (THA) component position that would improve hip stability. Previous work has demonstrated that spinal mobility may impact functional acetabular position when seated. We sought to determine whether patients who dislocate following THA have different sitting spinopelvic alignment or acetabular component orientation compared to patients who did not dislocate.

Methods

A consecutive series of 1000 patients underwent post-operative low-dose biplanar spine-to-ankle lateral radiographs in standing and sitting positions 1 year following THA. Twelve patients (1% of all patients) experienced hip dislocation. Patients were categorized as having normal lumbar spines (without radiographic arthrosis) or as having lumbar multi-level degenerative disc disease. Measurements of spinopelvic alignment parameters (including sacral slope, lumbar lordosis, and proximal femur angles) and acetabular component orientation in sitting position (functional inclination and functional anteversion) were performed.

Results

Patients who dislocated had significantly less spine flexion, less change in pelvic tilt, and more hip flexion from standing to sitting positions compared to patients with normal spines. In sitting position, dislocators had acetabular components with less functional inclination and less functional anteversion.

Conclusion

This study demonstrates that patients with fixed spinopelvic alignment from standing to sitting position are at higher risk of hip dislocation. Imaging patients from standing to sitting position using this technique can provide valuable information on whether a patient has fixed spinopelvic alignment with postural changes and is therefore at higher risk of dislocation.  相似文献   

8.
BackgroundThere is an interest in quantifying dynamic hip kinematics before and after total hip arthroplasty (THA) during chair-rising: one of daily life activities.MethodsThe study consisted of 21 patients who underwent unilateral total hip arthroplasty for symptomatic osteoarthritis. We obtained continuous radiographs using a flat-panel X-ray detector while the participants rose from chair. We assessed the pre and postoperative hip joint's movements using three-dimensional-to-two-dimensional model-to-image registration techniques. We also measured minimum liner-to-neck distances at maximum hip flexion and extension as anterior and posterior liner-to-neck distances, respectively. Multivariate analyses were applied to determine which factors were associated with liner-to-neck distances.ResultsThe cup inclination, cup anteversion, and stem anteversion averaged 37.4°, 23.1°, and 30.1°, respectively. Significantly larger maximum hip flexion angle (72°) was found during chair-rising after THA compared to that before THA (63°, P < 0.01). The anterior pelvic tilt at the maximum hip flexion after THA (3° of anterior tilt) was significantly (P < 0.05) anterior compared to that before THA (1° of posterior tilt). The anterior and posterior liner-to-neck distances averaged 12.3 mm and 8.1 mm, respectively, with a significant difference (P < 0.01). No liner-to-neck contact was found in any hips. In multivariate analysis, the hip flexion angle, cup inclination, stem anteversion and head diameter were significantly associated with the anterior liner-to-neck distance (P < 0.05), the hip extension angle, cup anteversion, neck length and with or without elevated rim were significantly associated with the posterior liner-to-neck distance (P < 0.05, 0.01, 0.05, 0.01, respectively).ConclusionThis study indicates that well-positioned THA provide increased range of hip flexion with sufficient anterior liner-to-neck clearance during chair-rising. Dynamic hip kinematics, component position, and hardware variables significantly influenced on the liner-to-neck clearance under weight-bearing conditions.  相似文献   

9.
10.
In some atypical patients, pelvic sagittal inclination (PSI) changes posteriorly by > 10° from supine to standing position before total hip arthroplasty (THA). Several studies have suggested PSI in standing position is related to lumbar degeneration. The purpose of this study was to investigate spinal factors influencing changes in PSI from supine to standing position before THA. Participants comprised 163 consecutive patients who had undergone THA. Presence of compression fractures, presence of lumbar spondylolisthesis, thoracic kyphosis angle, lumbar lordosis angle, S1 anterior tilt angle and T4 plumb line position were investigated as spinal factors. Presence of compression fractures, age, presence of lumbar spondylolisthesis and small S1 anterior tilt angle were independently associated with posterior change in PSI from supine to standing position in patients before THA.  相似文献   

11.

Background

We investigated the relationship between pelvic incidence (PI) with anterior pelvic plane angle (APPA), pelvic tilt (PT) angle, and sacral slope (SS) in standing and sitting positions to identify the best parameter expressing the pelvic functional orientation in the sagittal plane.

Methods

We enrolled 109 consecutive patients (M:F = 43:66) eligible for a primary total hip arthroplasty (THA) with an average age of 63.4 years (15-85). EOS 2D/3D radiography was performed in standing and sitting positions before THA to evaluate the functional pelvic orientation. 3D images took into account the patient-specific sagittal balance measuring APPA, PT, SS, and PI.

Results

In standing position, functional parameters measured 5° ± 7.1 for APPA, 11° ± 8.3 for PT, 43° ± 8.5 for SS, and 53° ± 10.9 for PI. In sitting position, they were ?18° ± 10.4 for APPA, 34° ± 11.8 for PT, 20° ± 12.6 for SS, and 54° ± 10.9 for PI. There was no significant difference between men and women in terms of the functional parameters in both positions. No relationship was found between APPA and PI in both positions. SS correlated with PI in standing (r = 0.66; P < .0001; R2 = 0.44) and sitting (r = 0.51; P < .0001; R2 = 0.26). PT correlated with PI in standing (r = 0.65; P < .0001; R2 = 0.42) and sitting (r = 0.38; P < .0001; R2 = 0.14).

Conclusion

SS shows the highest correlation with functional pelvic tilt. The study suggests that adjustments in acetabular anteversion during primary THA should be based on SS.  相似文献   

12.
13.
Optimization of the combined anteversion of cup and stem has been emphasized to avoid prosthetic impingement in total hip arthroplasty (THA). However, no study has focused on the impact of variations in sagittal and coronal stem tilt against the whole femur on prosthetic range of motion. The purposes of the present study were a) to quantify the anatomical variation of sagittal and coronal tilt of the proximal canal axis against the femoral retrocondylar coordinate system, that is variation of sagittal and coronal stem tilt and b) to determine their impact on the zone of impingement‐free cup position using computer simulation. Preoperative computed tomography images of 477 femurs from 409 consecutive patients who underwent THA using computed tomography‐based computer navigation were stored. Virtual implantation of an anatomical stem was performed on the navigation workstation. The safe zone of the cup position with regard to prosthetic impingement was determined by motion simulation in the range of sagittal and coronal stem tilt of the subjects. The sagittal and coronal stem tilt varied by 10°, which was smaller than the stem anteversion variation. However, there was about 3 times the difference in the impingement‐free zone of cup position in the ranges of sagittal and coronal stem tilt. The safe zone was significantly decreased by posterior tilt and valgus tilt of the stem. Range of motion simulation revealed that the variations in sagittal or coronal stem tilt significantly influenced the safe zone of the cup. In conclusion, although the variations in sagittal and coronal stem tilt against the femoral retrocondylar coordinate system were small, their impact on prosthetic impingement was significant.  相似文献   

14.

INTRODUCTION

The orientation of acetabular component is influenced by pelvic tilt, body position and individual variation in pelvic parameters. Most post-operative adverse events may be attributed to malposition of the component in the functional position. There is evidence that orientation of the pelvis changes from the supine to standing position. Authors report a case of recurrent dislocation after total hip arthroplasty due to excessive pelvic tilting.PRESENTATION OF CASE A 69-year old female with coxarthrosis had undergone total hip replacement with recurrent dislocation of the hip on bearing weight in spite of using constrained acetabular component.

DISCUSSION

Our case report substantiates the influence of pelvic tilt, incurred by a sagittal deformity of spine, on dynamic orientation of the acetabular cup which was positioned in accordance with the anatomic landmarks alone. If the reference is only bony architecture and dynamic positions of the pelvis are not taken into account, improper functional orientation of the acetabular cup can result in sitting and standing positions. These can induce instability even in anatomically appropriately oriented acetabular component.

CONCLUSION

The sagittal position of pelvis is a key factor in impingement and dislocation after total hip arthroplasty. Pelvic tilting affects the position of acetabular component in the sagittal plane of the body as compared with its anatomic position in the pelvis. We suggest a preoperative lateral view of spine-pelvis, in upright and supine position for evaluation of a corrective adaptation of the acetabular cup accordingly with pelvic balance.  相似文献   

15.
BackgroundsThere are very few reports on pelvic movement during total hip arthroplasty (THA) in the supine position. We investigated intraoperative pelvic motion in the sagittal and axial planes to determine if preoperative clinical factors, including body mass index (BMI) affect intraoperative pelvic motion.MethodsFifty-three patients with osteoarthritis undergoing THA in the supine position were included. Clinical factors, such as age, BMI, and pelvic tilt were assessed preoperatively. Intraoperative pelvic motion in the axial and sagittal planes was assessed using a portable navigation system. We assessed the change in pelvic tilt from registration to cup implantation as the pelvic tilt change; positive values indicated anterior pelvic tilt. We measured the values and absolute values of changes in axial rotation from registration to cup implantation to determine the axial rotation angle. The effects of patient factors on pelvic motion (pelvic tilt change and axial rotation angle) were analyzed using a Spearman's correlation analysis.ResultsPreoperative pelvic tilt was negatively correlated with pelvic tilt change (r = −0.57, p < 0.05) and the absolute axial rotation angle (r = −0.57, p < 0.05). BMI and absolute axial rotation angle were negatively correlated (r = −0.54, p < 0.05). Age was not correlated with change in the pelvic tilt and the axial rotation angle.ConclusionsPreoperative pelvic tilt and BMI are important factors to determine intraoperative pelvic motion in patients who undergo THA in the supine position. This can help surgeons to preoperatively identify patients with a higher risk of intraoperative pelvic motion.  相似文献   

16.
BackgroundRecent research has demonstrated that patients with reduced pelvic mobility from standing to sitting have higher rates of dislocation after total hip arthroplasty (THA). This study evaluates the effect of sagittal spinal deformity, defined by pelvic incidence–lumbar lordosis mismatch (PI-LL), on postural changes in pelvic tilt (PT).MethodsA multicenter database of 1100 preoperative THA patients was queried. Anterior-pelvic-plane tilt (APPt), spinopelvic tilt (SPT), and LL were measured from radiographs of patients in supine, standing, flexed-seated, and stepping-up postures; PI was measured from computed tomography. Patients were separated into 3 groups based on PI-LL (<?10°, ?10° to 10°, >10°) and propensity-score matched by PI. Lumbar flatback-deformity was defined as PI-LL > 10°, hyperlordosis: PI-LL < ?10°. SPT/APPt, including changes between each posture were compared across PI-LL groups using analysis of variance, with post-hoc Tukey tests. Pearson correlations were reported when testing associations between SPT/APPt change and PI-LL.ResultsAfter propensity-score matching, 288 patients were analyzed (mean 65 y; 49% F). SPT and APPt change differed across all PI-LL categories from standing to seated, supine, and stepping-up with less SPT/APPt recruitment among hyperlordotic vs flatback patients (all P < .001). Greater PI-LL correlated with greater SPT recruitment from standing to seated (R = 0.294), supine (R = 0.292), and stepping-up (R = 0.207) (all P < .001). Smaller LL changes from standing to seated were associated with greater SPT recruitment (R = 0.372, P < .001).ConclusionsPostural changes in SPT/APPt are associated with spinopelvic measures in THA candidates. Hyperlordotic patients tend to utilize their spines more compared with flatback patients who were more likely to recruit PT. Increased focus on patients with lumbar flatback and hyperlordosis may help in reducing prosthetic dislocation prevalence following THA.  相似文献   

17.
《The Journal of arthroplasty》2019,34(11):2652-2662
BackgroundIn patients requiring both total hip arthroplasty (THA) and lumbar spinal fusion (LSF), consideration of preoperative sagittal spinopelvic measurements can aid in the prediction of postfusion compensatory changes in pelvic tilt (PT) and inform adjustments to traditional THA cup anteversion. This study aims to identify relationships between spinopelvic measurements and post-THA hip instability and to determine if procedure order reveals a difference in hip dislocation rate.MethodsPatients at a single practice site who received both THA and LSF between 2005 and 2015 (292: 158 = LSF prior to THA, 134 = THA prior to LSF) were retrospectively reviewed for incidents of THA instability. Those with complete radiograph series (89) had their sagittal (standing) spinopelvic profiles measured preoperatively, immediately postoperatively, and 3 months, 6 months, 1 year, 1.5 years, and 2 years postoperatively. Measured parameters included lumbar lordosis (LL), pelvic incidence (PI), PT, and sacral slope (SS).ResultsNo significant differences in dislocation rates between operative order groups were elicited (7/73 LSF first, 4/62 THA first; Z = 0.664, P = .509). Compared to nondislocators, dislocators had lower LL (−10.9) and SS (−7.8), and higher PT (+4.3) and PI-LL (+7.3). Additional risk factors for dislocation included sacral fusion (relative risk [RR] = 3.0) and revision fusion (RR = 2.7) . Predictive power of the model generated through multiple regression to characterize individual profiles of post-LSF PT compensation based on perioperative measurements was most significant at 1 year (R2 = 0.565, F = 0.000456, P = .028) and 2 years (R2 = 0.741, F = 0.031, P = .001) postoperatively.ConclusionIn performing THA after LSF, it is theoretically ideal to proceed with THA at a postfusion interval of at least 1 year, beyond which further compensatory PT change is minimal. However, the order of surgical procedure revealed no statistical difference in hip instability rates. In cases characterized by large PI-LL mismatch (larger or less predictable compensation profiles) or large SS or LL loss (considerably atypical muscle recruitment), consideration of full functional anteversion range between sitting and standing positions to account for abnormalities not appreciated with standing radiographic assessment alone may be warranted.  相似文献   

18.
BackgroundThis study of patients with hip primary osteoarthritis and a matched, asymptomatic, volunteers (controls) group aimed to determine spinopelvic differences between the two groups and their consequences for total hip arthroplasty.Methods104 patients (52 in each group) had their sagittal spinopelvic parameters (lumbar lordosis angle, sacral slope, pelvic tilt, pelvic incidence, and the pelvic-femoral angle) measured in the standing, relaxed-seated, and deep-flexed seated positions. Spinopelvic movement was calculated as the change between the different positions, and individual spinopelvic mobility was classified in accordance with the change in pelvic tilt as previously described (ΔPT: stiff (<10°), normal (10-30°), and hypermobile (>30°)).ResultsTransitioning from the standing to relaxed-seated position, patients demonstrated 13? less hip flexion (P < .001), 12? more posterior pelvic tilt (P = .006), and 6? more lumbar flexion (P = .038) compared with controls. Transitioning from the standing to deep-flexed seated position, patients demonstrated 18? less hip flexion (P < .001), accompanied by a posterior and not an anterior pelvic tilt as in the controls (7? ± 14 vs ?6? ± 17; P < .001). Patients showed a higher percentage of spinopelvic hypermobility (19% vs 2%; P = .008).ConclusionThe reduced ability of flexion in the arthritic hip, leads to posterior pelvic tilt in the relaxed-seated position. This is associated with a likely compensatory increased lumbar flexion to keep an upright position. Therefore, spinopelvic hypermobility has to be defined as pathologic. When moving to the deep-flexed seated position, decreased flexion of the arthritic hip prevents the pelvis from tilting anteriorly while the lumbar spine performs a compensatory flexion by approximately the same amount compared with controls.Level of EvidenceLevel II, diagnostic study.  相似文献   

19.
BackgroundThe important relationship between sagittal spinal alignment and total hip arthroplasty (THA) is becoming well recognized. Prior research has shown a significant relationship between sagittal spinal deformity (SSD) and THA instability. This study aims at determining the prevalence of SSD among preoperative THA patients.MethodsA multicenter database of preoperative THA patients was analyzed. Radiographic parameters measured from standing radiographs included anterior pelvic plane tilt, spinopelvic tilt, and lumbar lordosis (LL); pelvic incidence (PI) was measured from computed tomography scans. Lumbar flatback was defined as PI-LL mismatch >10°, balanced as PI-LL of −10° to 10°, and hyperlordosis as PI-LL <−10°.ResultsA total of 1088 patients were analyzed (mean, 64 years; 48% female). And 59% (n = 644) of patients had balanced alignment, 16% (n = 174) had a PI-LL > 10°, and 4% (n = 46) had a PI-LL > 20° (severe flatback deformity). The prevalence of hyperlordosis was 25% (n = 270). Flatback patients tended to be older than balanced and hyperlordotic patients (69.5 vs 64.0 vs 60.8 years, P < .001). Spinopelvic tilt was more posterior in flatback compared to balanced and hyperlordotic patients (24.7° vs 15.4° vs 7.0°) as was anterior pelvic plane tilt (−7.1° vs −2.0° vs 2.5°) and PI (64.1° vs 56.8° vs 49.0°), all P < .001.ConclusionOnly 59% of patients undergoing THA have normally aligned lumbar spines. Flatback SSD was observed in 16% (4% with severe flatback deformity) and there was a 25% prevalence of hyperlordosis. Lumbar flatback was associated with increasing age, posterior pelvic tilt, and larger PI. The relatively high prevalence of spinal deformity in this population reinforces the importance of considering spinopelvic alignment in THA planning and risk stratification.  相似文献   

20.
《The Journal of arthroplasty》2023,38(8):1621-1627
BackgroundIliopsoas tendinopathy (IPT) can cause persistent groin pain and lead to dissatisfaction after total hip arthroplasty (THA). This study aimed to report the characteristics, incidences, risk factors, and treatment outcomes of IPT after THA.MethodsWe reviewed primary THAs performed at a single institution between January 2012 and May 2018. Clinical and radiographic analyses were performed on 1,602 THAs (1,370 patients). Patient characteristics, component sizes, inclination and anteversion angles, and antero-inferior cup prominence (≥8 millimeters (mm)), were compared between the groups with and without IPT. Changes in teardrop to lesser trochanter distance were measured to estimate changes in leg length and horizontal offset caused by THA. Logistic regression models were used to identify the risk factors for IPT. IPT was identified in 53 hips (3.3%).ResultsPatients with IPT had greater leg lengthening (12.3 versus 9.3 mm; P = .001) and higher prevalence of antero-inferior cup prominence (5.7 versus 0.4%; P = .002). There was no significant difference in inclination, anteversion, and horizontal offset change between the two groups. In multivariate analyses, greater leg lengthening, prominent acetabular cup, women, and higher body mass index were associated with IPT. All patients reported improvement in groin pain after arthroscopic tenotomy, while 35.7% with nonoperative management reported improvement (P < .001).ConclusionsSymptomatic IPT occurred in 53 (3.3%) of the 1,602 primary THAs. Our findings suggest that leg lengthening as well as prominent acetabular cup in THAs can be associated with the development of IPT. Arthroscopic tenotomy was effective in relieving groin pain caused by IPT.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号