首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
《The Journal of arthroplasty》2020,35(4):1003-1008
BackgroundWe compared the incidence of aseptic component loosening and subsequent revision, and the survival rate between ceramic titanium-nitride-coated mobile bearing (MB) and fixed bearing total knee arthroplasties (TKAs) performed in patients with moderate to severe varus deformities.MethodsIn total, 200 TKAs using advanced coated system posterior stabilized prostheses in varus deformity of mechanical axis >8° between 2012 and 2016 were retrospectively reviewed. One hundred MB (ceramic-m group) and 100 fixed bearing (ceramic-f group) prostheses were included. The matches were made according to preoperative demographics, range of motion, and severity of deformity. The mean follow-up period was not different (ceramic-m vs ceramic-f = 4.8 vs 5.1 years; P = .104). The incidence of revision TKA due to aseptic component loosening and the survival rate (failure: revision due to aseptic loosening) was investigated.ResultsThe incidence of revision TKA due to aseptic component loosening was 7 (7%) in the ceramic-m group and 1 (1%) in the ceramic-f group (P = .032). All cases of aseptic loosening occurred at the tibial component. The overall survival rate was 91.3% in the ceramic-m group and 98.9% in the ceramic-f group (P = .025).ConclusionConsidering the higher revision incidence and lower survival rate due to tibial component loosening, caution should be taken in tibial component fixation when using advanced coated system MB prosthesis in moderate to severe varus deformity.Level of EvidenceIII  相似文献   

2.
《The Journal of arthroplasty》2021,36(12):3883-3887
BackgroundTo assess how implant alignment affects unicompartmental knee arthroplasty (UKA) outcome, we compared tibial component alignment of well-functioning UKAs against 2 groups of failed UKAs, revised for progression of lateral compartment arthritis (“Progression”) and aseptic loosening (“Loosening”).MethodsWe identified 37 revisions for Progression and 61 revisions for Loosening from our prospective institutional database of 3351 medial fixed-bearing UKAs performed since 2000. Revision cohorts were matched on age, gender, body mass index, and postoperative range of motion with “Successful” unrevised UKAs with minimum 10-year follow-up and Knee Society Score ≥70. Tibial component coronal (TCA) and sagittal (TSA) plane alignment was measured on postoperative radiographs. Limb alignment was quantified by hip-knee-ankle (HKA) angle on long-leg radiographs. In addition to directly comparing groups, a multivariate logistic regression examined how limb and component alignments were associated with UKA revision.ResultsIn the Progression group, component alignment was similar to the matched successes (TCA 3.6° ± 3.5° varus vs 5.1° ± 3.5° varus, P = .07; TSA 8.4° ± 4.4° vs 8.8° ± 3.6°, P = .67), whereas HKA angle was significantly more valgus (0.3° ± 3.6° valgus vs 4.4° ± 2.6° varus, P < .001). Loosening group component alignment was also similar to the matched successes (TCA 6.1° ± 3.7° varus vs 5.9° ± 3.1° varus, P = .72; TSA 8.4° ± 4.6° vs 8.1° ± 3.9°, P = .68), and HKA was significantly more varus (6.1° ± 3.1° varus vs 4.0° ± 2.7° varus, P < .001). Using a multivariate logistic regression, HKA angle was the most significant factor associated with revision (P < .001).ConclusionIn this population of revised UKAs and long-term successes, limb alignment was a more important determinant of outcome than tibial component alignment.Level of EvidenceLevel III case-control study.  相似文献   

3.
《The Journal of arthroplasty》2019,34(6):1127-1131
BackgroundProper component positioning in total hip arthroplasty (THA) is crucial for implant fixation and hip stability. The purpose of this study is to assess if neutral coronal stem alignment (0° ± 3°) improved long-term survivorship in uncemented femoral components.MethodsBetween 2005 and 2010, 1028 primary THAs were performed with 2 contemporary dual-tapered, proximally coated uncemented stem types. Alignment was measured immediately postoperatively and at most recent follow-up. In total, 978 femoral stems (95%) were within 0° ± 3° of the neutral anatomic coronal axis, and the 50 stems (5%) outside that range were considered outliers (3.1° of valgus to 4.8° of varus). Outcomes analyzed included implant survivorship, Harris Hip Scores, and incidence of dislocation. Mean follow-up was 5 years.ResultsSurvivorship free of aseptic femoral component loosening was 99.3% and 98.2% at 5 and 8 years in the neutral group vs 100% at 5 and 8 years in the outlier group (P = .98). Survivorship free of femoral component revision for any reason was 99.1% and 97.3% at 5 and 8 years vs 100% at 5 and 8 years, respectively (P = .80). Harris Hip Scores were similar (89 in both groups; P = .84) at most recent follow-up. The incidence of mild to moderate thigh pain was also similar in both groups (6.1% vs 6%, P = .85). The incidence of dislocation was 1.5% at 8 years, and similar between both groups (P = .77).ConclusionSlight malalignment of contemporary dual-tapered uncemented THA femoral components does not appear to negatively impact survivorship or clinical outcomes, which is in contrast to cemented femoral components.Level of evidence IIICase-control study.  相似文献   

4.
《The Journal of arthroplasty》2020,35(6):1591-1594.e3
BackgroundRecently, the use of short tibial stems in the obese population undergoing total knee arthroplasty (TKA) has been proposed. Thus, we designed a study to assess tibial component survivorship after primary TKA using a single implant both with and without a fully cemented stem extension performed by a single surgeon.MethodsA search of our institutional research database was performed. A minimum 2-year follow-up was selected. Cohorts were created according to patient body mass index (BMI; >40 kg/m2 and <40 kg/m2) and the presence (stemmed tibia [ST]) or absence (non-stemmed tibia [NST]) of a short tibial stem extension. Kaplan-Meier survival analyses for aseptic loosening and log-rank tests were performed.ResultsA total of 236 patients were identified (ST = 162, NST = 74). Baseline patient characteristics were statistically similar between cohorts with the exception of BMI which was greater in the ST cohort (32.9 kg/m2, 30.6 kg/m2; P = .01). Kaplan-Meier survival analysis at 5 years was superior for the BMI < 40 kg/m2 cohort (98.9%, 93.1%; P = .045), the ST cohort (100%, 94.5%; P = .006), and the BMI > 40 kg/m2 with ST cohort at 4 years (71.4%, 100%; P = .008).ConclusionMorbid obesity and a short native tibial stem design appear to be associated with aseptic loosening in primary TKA. This appears to be mitigated through the use of an ST. As such, the use of ST may be considered in at-risk patients. Alternatively, implants with longer native stem designs can be employed. Modern short-stemmed tibial components may need to be redesigned.  相似文献   

5.
BackgroundBoth modular and monoblock tapered fluted titanium (TFT) stems have gained popularity over fully porous-coated cylindrical (FPCC) femoral stem designs, but limited data exist comparing subsidence rates following revision total hip arthroplasty (THA). The purpose of this study is to determine differences in subsidence and clinical outcomes among 3 revision femoral stem designs.MethodsWe reviewed a consecutive series of 335 patients who underwent femoral component revision to a cementless modular TFT (n = 225), monoblock TFT (n = 63), or FPCC (n = 47) stem between 2012 and 2019. We evaluated radiographic subsidence rates, re-revision rates, and patient-reported outcomes between the 3 stems. A multivariate regression analysis was performed to determine the independent effect of stem type on the risk of subsidence >5 mm.ResultsAt an average follow-up of 39 months (range, 12 to 96 months), there were no differences in mean subsidence rates (3.5 vs 2.4 vs 2.1 mm, P = .14), HOOS Jr scores (78 vs 74 vs 64 points, P = .15), or aseptic re-revision rates (4% vs 3% vs 0%, P = .29) between modular TFT, monoblock TFT, and FPCC stems. Although modular TFT stems were more often used in patients with extensive femoral bone loss (Paprosky III and IV), there were no differences in subsidence rates >5 mm among the 3 stems (P > .05) in multivariate analysis.ConclusionModular TFT, monoblock TFT, and FPCC femoral stem designs all perform well in revision THA with no difference in clinical outcomes or subsidence rates. Surgeons should select the stem which they feel is the most clinically appropriate.  相似文献   

6.
《The Journal of arthroplasty》2020,35(11):3166-3171
BackgroundThe goal of kinematically aligned (KA) total knee arthroplasty (TKA) is to restore native knee anatomy. However, there are concerns about patellofemoral tracking problems with this technique that lead to early revision. We measured the differences between preoperative anatomic alignment and postoperative component alignment in a consecutive series of KA TKA and evaluated the association between alignment changes and the likelihood of early revision.MethodsThe charts of 219 patients who underwent 275 KA TKA procedures were reviewed. Preoperative anatomic alignment and postoperative tibial and femoral component alignment were measured radiographically. The difference in component alignment compared with preoperative anatomic alignment was compared between patients who underwent aseptic revision and those who did not at a minimum of 12 months of follow-up. Receiver operating characteristic curves were created for statistically significant variables, and the Youden index was used to determine optimal alignment thresholds with regard to likelihood of revision surgery.ResultsChange in tibial component alignment compared with native alignment was greater (P = .005) in the revision group (5.0° ± 3.7° of increased varus compared with preoperative anatomic tibial angle) than in the nonrevision group (1.3° ± 4.2° of increased varus). The Youden index indicated that increasing tibial varus by >2.2° or more is associated with increased likelihood of revision. Preoperative anatomic alignment and change in femoral alignment and overall joint alignment (ie, Q angle) were not associated with increased likelihood of revision.ConclusionSmall increases in tibial component varus compared with native alignment are associated with early aseptic revision in patients undergoing KA TKA.  相似文献   

7.
BackgroundModular tibial stem extensions in total knee arthroplasty (TKA) are designed to reduce the risk of aseptic loosening of the tibial base plate. However, these implants add significant cost and an evaluation of their effectiveness in reducing this risk of loosening has not been studied in a large cohort. We sought to evaluate modular tibial stem utilization in primary TKA.MethodsWe conducted a cohort study using our integrated healthcare system’s Total Joint Replacement Registry. Patients who underwent cemented primary TKA were identified (2009-2019). Propensity scores were used to 1:1 match patients without to those with a stem extension. Cox proportional-hazards regression was used to evaluate the risk for revision due to aseptic loosening.ResultsTen thousand four hundred seventy six TKA with a modular tibial stem were matched to 10,476 TKA without a tibial stem. Stem utilization associated with a lower risk of revision for loosening across all postoperative follow-up (hazard ratio = 0.38, 95% confidence interval = 0.17-0.85).ConclusionIn a matched cohort study, we observed presence of a stem extension was associated with a lower risk of revision for aseptic loosening. Further study to identify specific risk factors for aseptic loosening and confirm the findings presented here are warranted.Level of EvidenceLevel III.  相似文献   

8.
BackgroundThe thickness of the polyethylene bearing in medial unicondylar knee arthroplasty (UKA) is determined by the depth of the tibial resection, degree of correctable deformity, and balance of the knee. The purpose of this study is to evaluate whether polyethylene thickness in medial mobile-bearing UKA impacts clinical outcomes and survivorship.MethodsA retrospective review from 2004 to 2017 identified patients who underwent a primary mobile-bearing medial UKA with 2-year minimum follow-up or revision. A total of 2305 patients (3030 knees) met inclusion criteria. Patients were divided in 2 groups: thin bearing (group 1): 3-mm or 4-mm bearing and thick bearing (group 2): ≥ 5 mm. The thin group consisted of 2640 knees (87%), whereas the thick group had 390 knees (13%). Preoperative and postoperative demographics, range of motion, Knee Society scores, complications, and reoperations were evaluated.ResultsMean follow-up was 5.2 years (range, 0.5 to 12.6). There was no significant difference between groups in postoperative range of motion or Knee Society scores (P > .05). Manipulations were performed in 1.3% of patients and not significantly different between groups. The all-cause revision rate for group 1 was 4.02% and group 2 was 4.58% (P = .6). Revision rates for tibial aseptic loosening were significantly higher in group 2 (1.8%) than those in group 1 (0.7%) (P = .04). There was no significant difference in failure rates between groups for tibial collapse or fracture, femoral aseptic loosening, arthritic progression, bearing dislocation, or other cause of revision.ConclusionThis study demonstrated that thicker bearings in medial UKA increased the risk of tibial aseptic loosening, but not all-cause failures or clinical outcomes.  相似文献   

9.
《The Journal of arthroplasty》2023,38(9):1793-1801
BackgroundThe primary aim was to assess whether a short (125 millimeter (mm)) stem offered an equivalent hip-specific function compared to the standard (150 mm) stem when used for cemented total hip arthroplasty. Secondary aims were to evaluate health-related quality of life, patient satisfaction, stem height and alignment, as well as radiographic loosenings and complications between the two stems.MethodsA prospective twin-center double-blind randomized control trial was conducted. During a 15-month period, 220 patients undergoing total hip arthroplasty were randomized to either a standard (n = 110) or a short (n = 110) stem. There were no significant (P ≥ .065) differences in preoperative variables between the groups. Functional outcomes and radiographic assessment were undertaken at a mean of 1 and 2 years.ResultsThere were no differences (P = .428) in hip-specific function according to the mean Oxford hip scores at 1 year (primary endpoint) or at 2 years (P = .622) between the groups. The short stem group had greater varus angulation (0.9 degrees, P = .003) when compared to the standard group and were more likely (odds ratio 2.42, P = .002) to have varus stem alignment beyond one standard deviation from the mean. There were no significant (P ≥ .083) differences in the forgotten joint scores, EuroQol-5-Dimension, EuroQol-visual analogue scale, short form 12, patient satisfaction, complications, stem height, or radiolucent zones at 1 or 2 years between the groups.ConclusionThe cemented short stem used in this study had equivalent hip-specific function, health-related quality of life, and patient satisfaction when compared to the standard stem at mean 2 years post operation. However, the short stem was associated with a greater rate of varus malalignment, which may influence future implant survival.  相似文献   

10.
BackgroundThe purpose of this study is (1) to find the clinical and radiological outcome of intraoperative bony avulsion of medial collateral ligament (MCL) treated with screw and washer construct and (2) to predict the preoperative factors which may contribute to the avulsion-type MCL injury during primary total knee arthroplasty (TKA).MethodsIntraoperative MCL avulsion injury occurred in 46 (0.8%) of the 4916 consecutive primary TKA from January 2011 to December 2015. After exclusion, the 41 knees were matched 1:2 with controls without MCL injury and compared for the various clinical, radiological, and functional parameters. The clinical parameters analyzed were age, gender, body mass index, preoperative diagnosis like osteoarthritis or rheumatoid arthritis, range of motion, sagittal deformity, and vitamin D levels. The radiological parameters calculated were coronal deformity, proximal tibial varus angle, distal femur valgus angle, joint line congruence angle, posterior tibial slope, “cup and saucer” morphology, presence or absence of knee subluxation, tibia vara, and femoral bowing. The preoperative and postoperative Knee Society Score and Knee Society Functional Score were analyzed. Complications or revisions, if any, were noted during the follow-up. Multivariate logistic regression analysis was used to predict the preoperative risk factors for MCL avulsion injury.ResultsAt a mean follow-up of 58.4 ± 19.3 months, there were no radiological or physical examination findings of instability. Compared to the preoperative disability, there was a statistically significant improvement in clinical scores (Knee Society Score and Knee Society Functional Score) in the final follow-up (P < .001) in both cases and the control group. The mean preoperative coronal deformity was 170.6 ± 6.96 in the study group and 167.7 ± 4.3 in the control group (P = .021). The mean preoperative tibial slope was 10.5 ± 4.9 in the study group and 7.91 ± 4.15 in the control group (P = .003). The preoperative knee subluxation was present in 48.8% knees (P < .001) and “cup and saucer” morphology in 68.3 knees (P < .001) in the study group. The adjusted odds of MCL avulsion injury were greater for severe varus deformity (odds ratio [OR] 1.462, 95% confidence interval [CI] 1.15-1.86), knee subluxation (OR 39.78, 95% CI 3.78-418.86), and “cup and saucer” morphology (OR 33.11, 95% CI 5.69-192.66).ConclusionIntraoperative MCL bony avulsion injury can be managed successfully with screw and washer construct without the need for increased prosthetic constraint in primary TKA. The presence of severe varus deformity, knee subluxation, and “cup and saucer” morphology tend to have an increased chance of MCL avulsion injury.  相似文献   

11.
BackgroundThe effect of total knee arthroplasty (TKA) on the ankle joint is not entirely clear. The purpose of this study is to assess postoperative changes in the coronal alignment of the ankle joint in patients undergoing TKA for various degrees of knee deformity.MethodsThis retrospective study included 107 patients who had undergone TKA for primary osteoarthritis. In all cases, preoperative coronal alignment deformity of the knee was corrected in an attempt to restore the native mechanical axis of the knee. Patients were stratified into 3 groups according to the degree of knee coronal alignment correction achieved intraoperatively: group 1 (<10° varus/valgus correction, n = 60), group 2 (≥10° varus correction, n = 30), and group 3 (≥10° valgus correction, n = 17). Knee/ankle alignment angles were measured on full-length, standing anteroposterior imaging preoperatively and postoperatively and included the following: hip-knee-ankle angle, tibial plafond inclination (TPI), talar inclination (TI), and tibiotalar tilt angle.ResultsSignificant changes in ankle alignment, specifically with regard to TPI (9.5° ± 6.9°, P < .01) and TI (8.8° ± 8.8°, P = .03) were noted in the ≥10° valgus correction group compared to the other 2 groups. Regardless of the degree of knee deformity correction, TKA did not lead to significant changes in the tibiotalar tilt angle.ConclusionA correction of ≥10° in a genu valgum deformity can affect ankle joint alignment, leading to alterations in TPI and TI. These findings need to be taken into consideration in assessing candidates for TKA as a possible cause of postoperative ankle pain.  相似文献   

12.
《The Journal of arthroplasty》2020,35(7):1868-1876
BackgroundAdequate interference fit and mechanical stability through optimal surgical technique are essential to prevent subsidence and loosening in cementless total hip arthroplasty. The purpose of this study is to determine the effect of surgical technique on radiographic subsidence and subsequent stability of a modern taper-wedge cementless stem.MethodsA retrospective review of 250 consecutive cementless primary total hip arthroplasties performed by 2 surgeons was completed. Surgeon A vigorously broached, maximizing the mediolateral stem dimension and confirmed final broach stability with a torsional test, whereas Surgeon B did not. All patients received identical taper-wedge stems. Preoperative bone morphology (canal flare index), postoperative subsidence, and canal fill were radiographically assessed.ResultsCanal flare index was not different between groups (P = .747). There was significantly less subsidence at 1 month for Surgeon A (0.3 vs 1.3 mm, P < .001). Additional subsidence at 1 year occurred in only 0.8% of Surgeon A (1/119) compared to 51.6% of Surgeon B stems (33/64, P < .001). Surgeon technique and canal fill measured at 60 mm below the lesser trochanter were the only variables predictive for subsidence, where Surgeon A and B had a mean canal fill of 95% and 86%, respectively. Surgeon B had 2 cases of aseptic loosening (2%) at 2 and 3 years postoperatively.ConclusionThese observations support that maximizing mediolateral canal fill and avoiding under-sizing the femoral implant with meticulous broaching technique minimizes subsidence and optimizes stability of modern cementless taper-wedge stems. Failure to optimize canal fill with appropriate broaching and surgical technique may predispose femoral components to failure from aseptic loosening.  相似文献   

13.
《The Journal of arthroplasty》2022,37(12):2394-2398
BackgroundIn revision total knee arthroplasty, zonal fixation methods with a combination of augments, press-fit stems, and sleeves are popular. We hypothesized that high distal femoral augmentation with diaphyseal press-fit stems leads to an increased rate of early aseptic loosening and that femoral metaphyseal sleeves improve implant survival. Therefore, we retrospectively investigated implant survival in relation to augment heights and sleeves.MethodsA total of 136 patients with mean clinical follow-up of 50 months (range, 28-85) who underwent modular total knee arthroplasty and revision total knee arthroplasty with semiconstrained implants between January 2012 and July 2018 were retrospectively evaluated. Implant survival with 4, 8, and 12 mm distal femoral augments was compared to no distal augmentation. Subsequently, a subgroup analysis was performed for femoral sleeve implantation.ResultsWe observed an implant survival rate of 97.0%, 87.5%, and 69.2% for 4, 8, and 12 mm distal femoral augmentation, respectively (P = .73; P = .19; P = .008). The implant survival rate with femoral sleeves was 95.8% for the 8 mm augments and 85.7% for the 12 mm augments (P = .42; P = .96). Without femoral sleeves, the implant survival rate was 78.3% with the 8 mm augments and 50.0% with the 12 mm augments (P = .02; P < .001).ConclusionHigher rates of aseptic femoral loosening were identified for distal femoral augmentation of 8 mm or more without metaphyseal sleeve fixation in semiconstrained implants. Thus, in cases with femoral metaphyseal bone damage requiring high distal femoral augmentation, metaphyseal sleeves should be used to avoid early aseptic femoral loosening.  相似文献   

14.
《The Journal of arthroplasty》2020,35(8):2072-2075
BackgroundThe effect of using thicker liners in primary total knee arthroplasty (TKA) on functional outcomes and aseptic failure rates remains largely unknown. As such, we devised a multicenter study to assess both the clinical outcomes and survivorship of thick vs thin liners after primary TKA.MethodsA search of our institutional databases was performed for patients having undergone bilateral (simultaneous or staged) primary TKA with similar preoperative and surgical characteristics between both sides. Two cohorts were created: thick liners and thin liners. Outcomes collected were as follows: change in Knee Society Score (ΔKSS), change in range of motion, and aseptic revision. Ad hoc power analysis was performed for ΔKSS (⍺ = 0.05; power = 80%). Differences between cohorts were assessed.ResultsAbout 195 TKAs were identified for each cohort. ΔKSS and change in range of motion in the thin vs thick cohorts were similar: 51.4 vs 51.6 (P = .86) and 11.1° vs 10.0° (P = .66), respectively. No difference in aseptic revision rates were observed between thin and thick cohorts: all cause (4.1%, 3.1%; P = .59), aseptic loosening (0.5%, 0.5%; P = 1.0), instability (0.5%, 0.5%; P = 1.0), all-cause revision for stiffness (3.1%, 2.1%; P = .52), manipulation under anesthesia (2.1%, 2.1%; P = 1.0), and liner exchange (0.5%, 0%; P = .32).ConclusionThe results of this study suggest that both rates of revision surgery and clinical outcomes are similar for TKAs performed with thick and thin liners. Preoperative factors are likely to play an important role in liner thickness selection, and emphasis should be placed on ensuring sound surgical technique.  相似文献   

15.
《Foot and Ankle Surgery》2023,29(6):475-480
BackgroundThe subtalar joint may compensate for tibio-talar deformity, but what would happen to the joint after the deformity was corrected is not well known. Supramalleolar osteotomy (SMOT) is an effective procedure for the treatment of varus deformity of ankle arthritis. The objective of this study was to investigate the subtalar joint alignment pre and postoperatively following SMOT, and the factors which influenced the alignment of the subtalar joint.MethodsThirty-one patients with varus ankle arthritis (Takakura stage 2, 3a and 3b) who were treated using SMOT were retrospectively reviewed. The subtalar and ankle joint alignment was measured on weightbearing radiograph and weightbearing computerized tomography (WBCT).ResultsThe foot and ankle offset (FAO), tibial articular surface angle (TAS), tibio-talar surface angle (TTS), and subtalar vertical angle (SVA) were significantly corrected (P<0.05). The subtalar inclination angle (SIA) decreased in 19 patients and increased in the other 12 cases after the SMOT (P<0.001). The shift of subtalar joint (ΔSIA) showed an inverse correlation with the preoperative FAO (P<0.001, r = −0.621).ConclusionsThe shift of subtalar joint after SMOT could maintain the neutral position of the hindfoot and showed a negative correlation with the preoperative FAO. The ΔSIA was greater in the severer preoperative hindfoot deformity.Level of evidenceLevel IV, case series.  相似文献   

16.
《The Journal of arthroplasty》2023,38(3):535-540.e3
BackgroundIt is unknown if patients are relieved of pain after knee arthroplasty revision for unexplained pain. The aim of this cross-sectional case-control study was to compare patient-reported outcome measures (PROMs) and satisfaction 1 to 3 years after revision of total knee arthroplasties (TKAs) for the indications of unexplained pain versus aseptic loosening.MethodsWe included 384 patients undergoing TKA revision for the indications of unexplained pain and aseptic loosening from January 1, 2018 to December 31, 2020 from the Danish Knee Arthroplasty Register. A total of 81 patients were revised for unexplained pain and 303 for aseptic loosening. Questionnaires including PROMs (Oxford Knee Score, EQ-5D-5L, and Forgotten Joint Score) and satisfaction with the surgery on a 0-100 scale (100 = not satisfied; 0 = very satisfied) were sent to digitally secured mailboxes. Time from revision to data collection was a median 3.1 years (range, 1.4-4.4 years).ResultsMedian Oxford Knee Score was 25 (interquartile range [IQR] 15) versus 31 (IQR 18) 1-3 years after revisions for unexplained pain versus aseptic loosening, P = .009. Median EQ-5D-5L was 0.6 (IQR 0.4) versus 0.8 (IQR 0.3) for unexplained pain versus aseptic loosening, P = .009. Median Forgotten Joint Score was 50 (IQR 7) versus 50 (IQR 16) for unexplained pain versus aseptic loosening, P = .905. Satisfaction was 75 (IQR 38) for unexplained pain and 50 (IQR 73) for aseptic loosening, P < .001.ConclusionPatients undergoing TKA revision for the indication of unexplained pain had worse results on PROMs than those revised for aseptic loosening. Likewise, patients revised for unexplained pain were less satisfied compared to patients revised for aseptic loosening. This information is valuable to both surgeons and patients when candidates for revision surgery are selected, to obtain the best possible outcomes.  相似文献   

17.
《Seminars in Arthroplasty》2021,31(4):836-841
BackgroundThe purpose of this study was to compare the 5 year radiographic and clinical outcomes of anatomic total shoulder arthroplasties (TSA) performed with either a standard length (SL) or short stem. The hypothesis was there would be no difference in radiographic or clinical outcomes based on stem length.MethodsA multicenter retrospective review was performed of primary TSAs performed with a press-fit humeral component. Fifty SL and 72 short stems were available for review, of which 43 SL and 60 short stems had minimum 5 year follow-up. Functional outcome was assessed according to range of motion (ROM), visual analog scale (VAS) American Shoulder and Elbow Surgeons (ASES), and Single Assessment Numeric Evaluation (SANE) scores. Radiographs were reviewed for signs of humeral component loosening and stress shielding.ResultsAt final follow-up there were no differences in ROM, or ASES or SANE scores between groups (P>.05). Postoperative VAS scores were lower in the SL compared to the short stems (0.8 vs. 1.6; P = .053). All-cause revision was similar between the SL and short stems (16% vs. 22.2%; P = .395). Among SL stems there were no revisions for humeral loosening and none were considered radiographically at risk. Six short stems were revised for loosening (8.3%; P =.036 vs. SL). An additional 5 short stems were considered to be radiographically at risk for loosening for a total revision or at risk rate of 15.3% (P = .003 vs. SL).ConclusionThere is no difference in functional outcome at mid-term follow-up of TSA based on stem length with a grit-blasted humeral component. Revision for loosening and radiographic risk for loosening may be higher with a short stem compared a standard length humeral stem placed with press-fit fixation using grit blasting.Level of evidenceLevel III; Retrospective Comparative Study.  相似文献   

18.
BackgroundRevision of both femoral and tibial components of a total knee arthroplasty (TKA) for aseptic loosening has favorable outcomes. Revision of only one loose component with retention of others has shorter operative time and lower cost; however, implant survivorship and clinical outcomes of these different operations are unclear.MethodsBetween January 2009 and December 2019, a consecutive cohort of revision TKA was reviewed. Univariate and multivariable analyses were used to study correlations among factors and surgical related complications, time to prosthesis failure, and functional outcomes (University of California Los Angeles, Knee Society functional, knee osteoarthritis and outcome score for joint replacement, Veterans RAND 12 (VR-12) physical, and VR-12 mental).ResultsA total of 238 patients underwent revision TKA for aseptic loosening. The mean follow-up time was 61 months (range 25 to 152). Ten of the 105 patients (9.5%) who underwent full revision (both femoral and tibial components) and 18 of the 133 (13.5%) who underwent isolated revision had subsequent prosthesis failure [Hazard ratio (HR) 0.67, P = .343]. The factor analysis of type of revision (full or isolated revision) did not demonstrate a significant difference between groups in terms of complications, implant failures, and times to failure. Metallosis was related to early time to failure [Hazard ratio 10.11, P < .001] and iliotibial band release was associated with more complications (Odds ratio 9.87, P = .027). Preoperative symptoms of instability were associated with the worst improvement in University of California Los Angeles score. Higher American Society of Anesthesiologists status and higher Charlson Comorbidity Index were related with worse VR-12 physical (?30.5, P = .008) and knee osteoarthritis and outcome score for joint replacement (?4.2, P = .050) scores, respectively.ConclusionIsolated and full component revision TKA for aseptic loosening does not differ with respect to prosthesis failures, complications, and clinical results at 5 years. Poor American Society of Anesthesiologists status, increased comorbidities, instability, and a severe bone defect are related to worse functional improvement.Level of evidenceIII, cohort with control.  相似文献   

19.
《The Journal of arthroplasty》2021,36(9):3269-3274
BackgroundIn revision total hip arthroplasty (THA) cases with preserved femoral metaphyseal bone, tapered proximally porous-coated “primary” femoral stems may be an option. The objective of this study was to compare outcomes of patients with Paprosky I or II femoral bone loss undergoing revision THA with either a primary metaphyseal-engaging cementless stem or a revision diaphyseal-engaging stem.MethodsThis was a retrospective analysis of 70 patients with Paprosky I or II femoral bone loss who underwent femoral revision. 35 patients who were revised using a primary cementless femoral stem were compared with 35 patients who underwent femoral revision using a revision diaphyseal-engaging stem. The groups were similar regarding age, gender, body mass index, and American Society of Anesthesiologists. Clinical and radiographic outcomes and complications were compared over an average follow-up of 2.9 years (SD 1.4).ResultsRevision THA was most commonly performed for periprosthetic joint infection (N = 27, 38.6%). The groups were similar with regards to Paprosky femoral classification (P = .56), length of stay (P = .68), discharge disposition (P = .461), operative time (P = .20), and complications (P = .164). There were no significant differences between primary and revision femoral stem subsidence (0.12 vs. 0.75 mm, P = .18), leg length discrepancy (2.3 vs. 4.05 mm, P = .37), and Hip Disability and Osteoarthritis Outcome Score Jr (73.1 [SD 21.1] vs. 62.8 [SD 21.7], P = .088). No patient underwent additional revision surgery involving the femoral component.ConclusionUse of modern primary cementless femoral stems is a viable option for revision hip arthroplasty in the setting of preserved proximal femoral metaphyseal bone. Outcomes are not inferior to those of revision stems and offer potential benefits.  相似文献   

20.
《The Journal of arthroplasty》2020,35(11):3305-3310
BackgroundThis study aimed to investigate the change in ankle varus incongruencies following total knee replacement (TKR) in patients with preoperative genu varum deformity of ≥10°.MethodsThe study cohort was composed of patients who underwent TKR in a single institution for knee osteoarthritis with preoperative genu varum deformity of ≥10° and concomitant varus ankle incongruencies. Eight radiographic measurements were evaluated preoperatively and postoperatively: mechanical tibiofemoral angle, mechanical lateral distal femoral angle, medial proximal tibial angle, lateral distal tibial angle, tibial plafond inclination, talar inclination, tibiotalar tilt angle (TTTA), and tibia-mechanical axis angle. Of these, TTTA represented the quantitative degree of ankle joint incongruency.ResultsA total of 110 patients (male = 2; female = 108) were included in the analysis. The mean patient age was 68.9 (standard deviation [SD] 7.2) years at the time of TKR. All radiographic measurements showed significant changes postoperatively, representing the appropriate correction of genu varum deformity and restoration of the mechanical axis. Nineteen patients (17.3%) showed postoperative decrease in TTTA, 2 (1.8%) remained the same, and 89 (80.9%) showed increase. Overall, mean preoperative and postoperative TTTA were 3.3° (SD 2.2°) and 4.7° (SD 2.9°), respectively (P < .001), representing the aggravation of varus ankle incongruencies.ConclusionVarus ankle incongruencies showed aggravation following TKR despite correction of genu varum deformity and restoration of the mechanical axis. This could be an important cause of postoperative increase or development of ankle pain following TKR. Therefore, patients with preoperative varus ankle incongruencies need to be warned of possible aggravation of ankle symptoms and be evaluated before TKR.Level of EvidencePrognostic level III.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号