首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 12 毫秒
1.
《The Journal of arthroplasty》2021,36(9):3269-3274
BackgroundIn revision total hip arthroplasty (THA) cases with preserved femoral metaphyseal bone, tapered proximally porous-coated “primary” femoral stems may be an option. The objective of this study was to compare outcomes of patients with Paprosky I or II femoral bone loss undergoing revision THA with either a primary metaphyseal-engaging cementless stem or a revision diaphyseal-engaging stem.MethodsThis was a retrospective analysis of 70 patients with Paprosky I or II femoral bone loss who underwent femoral revision. 35 patients who were revised using a primary cementless femoral stem were compared with 35 patients who underwent femoral revision using a revision diaphyseal-engaging stem. The groups were similar regarding age, gender, body mass index, and American Society of Anesthesiologists. Clinical and radiographic outcomes and complications were compared over an average follow-up of 2.9 years (SD 1.4).ResultsRevision THA was most commonly performed for periprosthetic joint infection (N = 27, 38.6%). The groups were similar with regards to Paprosky femoral classification (P = .56), length of stay (P = .68), discharge disposition (P = .461), operative time (P = .20), and complications (P = .164). There were no significant differences between primary and revision femoral stem subsidence (0.12 vs. 0.75 mm, P = .18), leg length discrepancy (2.3 vs. 4.05 mm, P = .37), and Hip Disability and Osteoarthritis Outcome Score Jr (73.1 [SD 21.1] vs. 62.8 [SD 21.7], P = .088). No patient underwent additional revision surgery involving the femoral component.ConclusionUse of modern primary cementless femoral stems is a viable option for revision hip arthroplasty in the setting of preserved proximal femoral metaphyseal bone. Outcomes are not inferior to those of revision stems and offer potential benefits.  相似文献   

2.
We retrospectively reviewed 123 patients who underwent cementless THA with modular femoral stem designs for revision THA or conversion of failed ORIF and found 75 patients available for analysis. The Harris Hip Score (HHS) improved from 52 ± 14 to 86 ± 11 (P < 0.001). The femoral stem was re-revised in eight patients (11%). The mean time to re-revision was 1.1 years (0.13–2.54). Reasons for re-revision included infection (n = 5, 7%), aseptic loosening (n = 2, 3%) and significant pain (n = 1, 1%). There were no failures of the modular junctions. PC stems had an increased rate of intraoperative fractures (PC 28% vs. STS 9%, P = 0.04). Modular cementless femoral stems provide acceptable mid-term results in revision THA.  相似文献   

3.
Nineteen patients (nineteen hips) who had undergone revision total hip arthroplasties using a proximally-coated primary cementless stem were evaluated to determine if a subset of revision arthroplasty patients could be identified where the use of this stem would be appropriate. Of these 19 revisions, 15 were performed for the second stage treatment of infection. The femoral bone deficiency was classified as Paprosky Type I in 6 hips and Type II in 13 hips. At a mean follow-up of 49 months, aseptic stem survivorship was 95% with one revision due to aseptic stem failure. The mean Harris hip scores had improved from a mean of 44 points pre-operatively to 89 points post-operatively. Intra-operatively, there was one complication which included a peri-prosthetic fracture distal to the stem which was treated with an allograft strut with cerclage wires. The authors believe that in type I or II femoral defects, the use of this specific cementless stem may be beneficial in the setting of a revision total hip arthroplasty.  相似文献   

4.

Background

The Exeter cemented femoral stem has demonstrated excellent clinical and radiographic outcomes as well as long-term survivorship free from aseptic loosening. A shorter revision stem (125 mm) with a 44 offset became available for the purpose of cement-in-cement revision situations. In certain cases, this shorter revision stem may be used for various primary total hip arthroplasties (THAs) where the standard length stem would require distally reaming the femoral canal. We sought to report on the early to midterm results of this specific stem when used for primary THA regarding (1) clinical and radiographic outcomes, (2) complications, and (3) survivorship.

Methods

Twenty-nine patients (33 hips) underwent a hybrid THA using the smaller revision Exeter cemented femoral stem. Twenty-five patients (28 hips) had at least 2 years of follow-up and were assessed for clinical and radiographic outcomes. All 33 hips were included in the analysis of complications and survivorship. The Kaplan-Meier survivorship was performed using revision for all causes and for aseptic loosening as the end points.

Results

The average clinical follow-up was 4 years (range, 2-7). Harris Hip Scores improved from a mean preoperative value of 56 (range, 23-96) to 90 (range, 51-100) at the latest follow-up. All patients demonstrated superior cement mantles with no signs of loosening. One patient suffered a B2 periprosthetic fracture and 1 patient experienced 2 episodes of instability. The 5-year Kaplan-Meier survivorship was 96.7% for all causes of revision and was 100% using aseptic loosening as the end point.

Conclusion

The shorter Exeter revision cemented femoral stem has favorable early to midterm clinical and radiographic outcomes when used for primary THA with a low complication rate and is a viable option in patients with narrow femoral canals where uncemented stem fixation is not desired.  相似文献   

5.
BackgroundWe sought to evaluate the cause-specific revision risk following hybrid (cemented stem mated to a cementless acetabular implant) vs cementless total hip arthroplasty (THA) in a US cohort.MethodsPrimary elective THA for osteoarthritis was identified using Kaiser Permanente’s Total Joint Replacement Registry (2001-2018). Multivariable Cox regression was used to evaluate cause-specific revision, including aseptic loosening, infection, instability, and periprosthetic fracture (PPF), for hybrid vs cementless THA. Analysis was stratified by age (<65, 65-74, and ≥75 years) and gender.ResultsThe study cohort comprised 88,830 THAs, including 4539 (5.1%) hybrid THAs. In stratified analysis, hybrid THA had a higher revision risk for loosening in females in all 3 age subgroups. A lower risk of revision for PPF was observed following hybrid THA in females aged ≥75 years. For females ≥75 years, cementless THA had an excess PPF risk of 0.9% while hybrid THA had an excess loosening risk of 0.2%, translating to a theoretical prevention of 10 PPF revisions but a price of 3 loosening revisions per 1000 hybrid THAs. No difference in revision risk was observed in males.ConclusionWe observed differences in cause-specific revision risks by method of stem fixation which depended upon patient age and gender. Although the trend toward all cementless fixation continue, there may be a role for hybrid fixation in females ≥75 years to mitigate risk for revision due to PPF at the potential cost of a slight increase in longer term aseptic loosening.Level of EvidenceLevel III.  相似文献   

6.
《The Journal of arthroplasty》2023,38(5):855-861.e1
BackgroundCementless total hip arthroplasty (THA) femoral stems are the most commonly selected prostheses in the United States. Optimal stem geometry remains controversial with excellent survivorship reported for many designs. We compared cause-specific stem revision of single-wedge versus double-wedge designs from a multicenter US cohort.MethodsData from an integrated healthcare network’s total joint replacement registry were used to conduct a cohort study. Primary elective cementless THAs were identified (2001 to 2018). Implant exposure groups were classified by design geometry using the system proposed by Khanuja et al. Type 1 single-wedge (n = 11,082) and type 2 double-wedge (n = 32,380) designs were compared, and other design types were excluded; the final study cohort comprised 43,462 THAs. Cause-specific multivariable Cox regressions were used to evaluate risk for revision due to infection or aseptic reasons, including loosening, instability, periprosthetic fracture, or other reasons.ResultsAfter adjustment for covariates, a higher aseptic revision risk was observed for type 1 when compared to type 2 designs (hazard ratio = 1.91, 95% confidence interval = 1.33-2.75). When looking at specific revision reasons, revision for aseptic loosening (hazard ratio = 3.46, 95% confidence interval = 2.24-5.34) was higher for type 1 versus type 2 designs. No differences were found for septic revision, instability, periprosthetic fracture, or revisions for other reasons.ConclusionsType 1 single-wedge designs were found to have a higher risk of revision due to aseptic loosening relative to type 2 double-wedge designs. Femoral stem geometry should be considered when selecting a cementless femoral implant.Level of EvidenceLevel III.  相似文献   

7.
BackgroundAs the number of primary total hip arthroplasty (THA) cases increase, so does the demand for revision operations. However, long-term follow-up data for revision THA is lacking.MethodsA retrospective review was completed of patients who underwent revision THA at a single institution between January 2002 and October 2007 using a cementless modular stem. Patient demographic, clinical, and radiographic data was collected. Preoperative and postoperative patient-reported outcome scores were compared at a minimum of fourteen-year follow-up.ResultsEighty-four patients (89 hips) with a median age of 69 years (range, 28 to 88) at operation were included. Indications for revision included aseptic loosening (84.2%), infection (12.4%), and periprosthetic fracture (3.4%). Twenty-two hips sustained at least 1 complication: intraoperative fracture (7.9%), dislocation (6.7%), prosthetic joint infection (4.5%), deep venous thrombosis (3.4%), and late periprosthetic fracture (2.2%). There were no modular junction complications. Eight patients underwent reoperations; only three involved the stem. Thirty-eight patients (45%) were deceased prior to final follow-up without known reoperations. Twenty-seven patients (32%) were lost to follow-up. Twenty-one patients (23%) were alive at minimum fourteen-year follow-up. Complete patient-reported outcomes were available for nineteen patients (range, 14 to 18.5 years of follow-up). Significant improvement was seen in UCLA activity, VR-12 physical, hip disability and osteoarthritis outcome score, joint replacement., and Harris Hip score pain and function scores.ConclusionChallenges of long-term follow-up include patient migration, an unwillingness to travel for re-examination, medical comorbidities, advanced age, and death. The cementless modular revision stem demonstrated long-term clinical success and remains a safe and reliable option for complex revision operations.  相似文献   

8.
《The Journal of arthroplasty》2020,35(11):3242-3248
BackgroundTotal hip arthroplasty in patients with hip dysplasia is challenging as a result of complex anatomic deformities in the hip. The aim of the study was to evaluate the survivorship, the clinical and radiographic outcomes of cementless Wagner Cone stem in patients with dysplastic hip.MethodsThis retrospective study reports on 102 patients (135 hips) who have undergone total hip arthroplasty between 1993 and 1997. The mean age of patients was 51 years (range, 21-73). Minimum follow-up was 20 years. According to the Crowe classification, 38 hips presented dysplasia of grade I, 41 of grade II, 37 of grade III, and 19 of grade IV.ResultsKaplan-Meier survivorship for aseptic loosening was 97% (95% confidence interval, 94.4-99.6) at 20 years. The average Harris hip score increased from 43.4 points (range, 22-51) to 86.4 points (range, 39-100) (P < .0001) and average Merle d’Aubignè score increased from 8.4 (range, 4-13) to 15 (range, 5-18) (P < .0001); at the last follow-up, average University of California at Los Angeles activity score and visual analog score were 4.53 (range, 1-9) and 1.25 (range, 0-6), respectively; 17% of heterotopic ossification and 19.2% of radiolucency lines around the stem were reported.ConclusionMonoblock Wagner Cone stem is a reliable option in dysplastic hip with an excellent survivorship and good clinical and radiographic outcome in the long term.  相似文献   

9.

Background

The purpose of this study was to identify the incidence and types of complications after revision total hip arthroplasty (THA) within the first year, and determine the relative risk factors for these complications and of re-revision.

Methods

The sample size of 5% Medicare claims data from 1998-2011 was studied. Primary THA patients who underwent subsequent revision were identified using ICD-9-CM codes. Outcomes and complications after revision THA were assessed. Multivariate Cox regression was used to evaluate the effect of patient demographic characteristics on the adjusted complication risk for revision THA patients.

Results

Of the 64,260 primary THA patients identified between 1998 and 2011, 3555 patients (5.71%) underwent revision THA. Etiology of primary hip failure included mechanical complications such as loosening and wear (40.7%), dislocation (14.0%), and infection (11.3%). Complications after revision THA included infection and redo revision, 17.3% and 15.8% followed by venous thromboembolic disease (VTE) at 11.1%, dislocation at 5.43%, PE at 3.24%, and death at 2.11%. The rate of “new” infections after an aseptic revision was 8.13%. Patients in the 85+-year-old age group had a 100% greater adjusted risk of VTE (P < .001) and 406% higher adjusted risk of death (P < .001) than those in the 65-69 years-old age group. Patients with higher Charlson scores had higher adjusted risks of VTE (P < .001), infection (P < .001), death (P = .002), and re-revision THA (P = .011).

Conclusion

Advanced age is a clear risk factor for VTE and mortality, but not for dislocation, infection, or re-revision. Higher Charlson index was found to be a risk factor for every complication after revision except dislocation. Greater attention is required to address the high rate of infection and re-do revision after revision THA (17.3% and 15.8%).  相似文献   

10.

Background

Bone deficiency in revision total hip arthroplasty is a surgical challenge. The Murata-Chiba cup supporter (MC support ring) is an acetabular component supporter for a cementless porous-coated cup. The purpose of this study is to examine the clinical and radiographic outcomes of reconstruction of acetabular bone deficiency using iliac autografts supported by an MC support ring in a revision setting with minimum 15-year follow-up.

Methods

Fifty-nine consecutive revision total hip arthroplasties (57 patients) using the MC support ring were followed for a minimum of 15 years. Nine hips had American Academy of Orthopaedic Surgeons type II deficiency and 24 had type III defects of the acetabulum. Clinical outcomes were evaluated using the Harris hip score. Radiographic evaluation included assessment for loosening and bone graft incorporation. Kaplan-Meier survival analysis was performed.

Results

At a minimum 15-year follow-up (mean, 17.6 years), 32 patients (33 hips) were alive, 17 patients (18 hips) were deceased, and 8 patients (8 hips) were lost to follow-up. The mean Harris hip score improved from 44.3 to 77.2 at final follow-up. Four hips required reoperation due to deep infection (2 hips) and liner dissociation (2 hips), but no acetabular components were revised for aseptic loosening. Incorporation of the bone graft occurred in all cases. One unrevised patient had radiographic failure. Survivorship at 15 years with re-revision or radiographic failure as the end point was 90.6% (95% confidence interval, 83.0%-98.8%).

Conclusion

The reconstruction of acetabular bone deficiency using autografts supported by an MC support ring provided satisfactory clinical and radiological results at 17.6 years postoperatively.  相似文献   

11.

Background

Trabecular metal (TM)-coated acetabular components are increasingly used in both primary and revision total hip arthroplasty (THA). However, previous studies assessing TM acetabular components have been small single-center cohorts with most lacking a control group. We compared revision rates following primary THA between TM and non-TM-coated acetabular components.

Methods

A retrospective observational study was performed using National Joint Registry data, which included primary THAs with the same cementless acetabular component (either TM or non-TM coated). TM and non-TM implants were matched for multiple potential confounding factors using propensity scores. Outcomes following primary THA (revision for all-cause acetabular indications, aseptic acetabular loosening, and infection) were compared between matched groups using competing risk regression analysis.

Results

In 18,200 primary THAs (9100 TM and 9100 non-TM), the overall prevalence of acetabular revision, revision for aseptic acetabular loosening, and septic revision was 1.2%, 0.13%, and 0.59% respectively. Five-year revision rates for all-causes (1.0% vs 1.8%, sub-hazard ratio [SHR] 0.57, 95% confidence interval [CI] 0.43-0.76, P < .001), aseptic acetabular loosening (0.1% vs 0.2%, SHR 0.35, 95% CI 0.14-0.90, P = .029), and infection (0.5% vs 0.9%, SHR 0.51, 95% CI 0.34-0.76, P = .001) were all lower in TM compared with non-TM implants.

Conclusion

Following primary THA, TM-coated acetabular implants had a reduced risk of both aseptic and septic revision compared with non-TM implants. Although absolute differences in revision risk were small, they may be clinically significant if TM designs were implanted in more complex cases.  相似文献   

12.
Most reports on the use of modular femoral stems during revision surgery have involved short follow-up periods. The authors evaluated the clinical and radiographic performance of 59 patients fitted with a distal fix modular stem. The average follow-up period was 8.2 years. Average Harris hip score was improved from 47 to 87.6. Of 19 patients with trochanteric osteotomy, 4 had a displaced greater trochanter. Re-revision was performed in 5 patients, and 3 of these were for subsidence (of these 3, subsidence was associated with dissociation of the coupling part in 1 and with osteotomy nonunion in other 2 [proximal component only]). Modular distally fixed femoral stems were found to offer intraoperative flexibility, but to suffer from subsidence and intraoperative greater trochanter and metaphyseal femoral fractures.  相似文献   

13.

Background

Modular femoral stem provides flexibility in femoral reconstruction, ensuring improved “fit and fill”. However, there are risks of junction failure and corrosion, as well as cost concerns in the use of modular femoral stems.

Methods

We reviewed prospectively-gathered clinical and radiographic data on revision total hip arthroplasties (THAs) performed from 2001-2007 using modular, cementless femoral component performed by the 2 senior authors. Patients with a minimum follow-up of 7 years were included in this study.

Results

Sixty-four patients (68 hips) with a median age of 68 ± 14 years (range 40-92 years) at revision THA were included. The median follow-up was 11.0 ± 1.8 years (range 7-14). Harris hip score, femoral stem subsidence, and stem osseointegration were recorded. The Harris hip score improved from an average of 38.1-80.1 (P < .01). Five hips had one or more dislocations. Seven patients underwent reoperations, 3 of which did not involve the stem. Four stems required revision because of infection, recurrent dislocation, or suboptimal implant position. Survival rates for any reasons and revision for femoral stems were 90% and 94%, respectively, at the most recent follow-up. Four stems subsided more than 5 mm, but established stable osseointegration thereafter. Seven nonloose stems (10.2%) demonstrated radiolucent lines in Gruen zones 1 and 7. No complications regarding the modular junction were encountered.

Conclusion

Modular, cementless, extensively porous-coated femoral components have demonstrated intermediate-term clinical and radiographic success. Initial distal intramedullary fixation ensures stability, and proximal modularity further maximizes fit and fill.  相似文献   

14.
We report the first long-term results of a prospective cohort study after total hip arthroplasty using the cementless Bicontact hip stem. Between 1987 and 1990, 250 total hip arthroplasties in 236 patients were performed using the cementless Bicontact hip stem. The average follow-up was 22.8 years (20.4–24.8) and average age at index surgery was 58.1 years. Eighty-one patients died and 9 were lost to follow-up. We noted 11 stem revisions revealing an overall Kaplan Meier survival rate of 95.0% (CI 95%: 91.1–97.2%). The average Harris Hip Score revealed 81 points (range 24–93). The Bicontact hip stem demonstrated high survival rates despite high ages and osteopenic changes, which are equivalent to other long-term reports of cementless stem fixation.  相似文献   

15.
Despite the increasing volume of revision total hip arthroplasty (THA) being performed in the United States, there are few studies reporting mid-term clinical and radiographic outcomes of modular fully porous-coated femoral stems. We retrospectively studied a consecutive series of patients who underwent revision THA with a modular extensively porous-coated femoral component at a single institution and by a single surgeon. The final study group included 54 hips (52 patients) followed for an average of 84 months. Ten-year survival rates with revision for any reason and revision for femoral loosening as endpoints were 94% and 100%, respectively. No complications regarding the modular junction were encountered. Of the 50 hips with adequate radiographs, all showed proximal ingrowth and 42 (84%) had both proximal and distal ingrowth. The modular, fully porous-coated femoral stem studied demonstrated excellent survivorship and bone ingrowth at mid-term follow up.  相似文献   

16.
《The Journal of arthroplasty》2020,35(12):3697-3702
BackgroundThe use of an extensively porous-coated uncemented cobalt-chrome monoblock femoral stem for revision total hip arthroplasty (THA) is well established with excellent mid-term results. The aim of this study is to report the long-term survivorship of these implants in femoral stem revisions.MethodsThis is a long-term retrospective review of prospectively collected data of 55 femoral stem revisions in 55 patients using a contemporary, cementless extensively porous-coated cobalt-chrome monoblock stem. All patients between 2001 and 2006 who underwent first time femoral stem revision with a contemporary, cementless extensively porous-coated cobalt-chrome monoblock stem were included. Harris Hip Score, Western Ontario and McMaster Universities Index, and University of California Los Angeles activity scores were recorded preoperatively and at latest follow-up. Radiographs were analyzed for evidence of loosening, subsidence, osteolysis, and bony union. This study included 55 patients, comprising of 36 females (66%) and 19 males (34%) with a mean age of 66.4 ± 9.3 years at the time of surgery. The mean time interval from index procedure was 9.8 ± 2.9 years. Mean time from revision THA to final follow-up was 13.2 ± 2.17 years with a minimum of 10 years of follow-up.ResultsIndications for revision included aseptic loosening (33), prosthetic joint infection (13), and periprosthetic fracture (10). Significant improvement in Harris Hip Score (85.1 ± 1.77 vs 51.8 ± 2.3, P < .001), Western Ontario and McMaster Universities Index (17.6 ± 0.77 vs 33.3 ± 0.8, P < .001), and University of California Los Angeles (5.25 ± 0.2 vs 2.7 ± 0.36, P < .001) scores were found at latest follow-up compared to preoperative. Fifty-four patients (98%) achieved stable bony ingrowth on radiographic analysis. All 10 patients treated for periprosthetic fractures achieved bony union of their fractures. Two patients suffered intraoperative periprosthetic fractures and were treated with a cable-plating system. There were no mechanical failures and no femoral stem re-revisions. One patient was diagnosed with a deep infection and was treated with chronic suppressive antibiotic therapy due to significant medical comorbidities.ConclusionRevision of the femoral component with a contemporary extensively porous-coated cobalt-chrome femoral stem has excellent functional outcomes, radiographic outcomes, and long-term survivorship with minimal complications.  相似文献   

17.
BackgroundModular tibial stem extensions in total knee arthroplasty (TKA) are designed to reduce the risk of aseptic loosening of the tibial base plate. However, these implants add significant cost and an evaluation of their effectiveness in reducing this risk of loosening has not been studied in a large cohort. We sought to evaluate modular tibial stem utilization in primary TKA.MethodsWe conducted a cohort study using our integrated healthcare system’s Total Joint Replacement Registry. Patients who underwent cemented primary TKA were identified (2009-2019). Propensity scores were used to 1:1 match patients without to those with a stem extension. Cox proportional-hazards regression was used to evaluate the risk for revision due to aseptic loosening.ResultsTen thousand four hundred seventy six TKA with a modular tibial stem were matched to 10,476 TKA without a tibial stem. Stem utilization associated with a lower risk of revision for loosening across all postoperative follow-up (hazard ratio = 0.38, 95% confidence interval = 0.17-0.85).ConclusionIn a matched cohort study, we observed presence of a stem extension was associated with a lower risk of revision for aseptic loosening. Further study to identify specific risk factors for aseptic loosening and confirm the findings presented here are warranted.Level of EvidenceLevel III.  相似文献   

18.
BackgroundThe purpose of the present study was to update and report clinical outcomes and survival of primary total hip arthroplasty using a cementless double-tapered titanium fully hydroxyapatite-coated stem at a follow-up > 30 years.MethodsThe outcomes of this series of 347 primary total hip arthroplasties were already published at a follow-up > 25 years, during which only 12 stems were revised. Since then, there were two additional stem revisions, bringing the total to 14 stem revisions (all of which also required cup revision). Patients still living with the original stem were assessed using the modified Harris Hip Score and patient satisfaction (very satisfied, satisfied, dissatisfied, and very dissatisfied). Revision incidence was calculated using the Kaplan-Meier (KM) method and Cumulative Incidence Function (CIF) at 35 years.ResultsAt a mean follow-up of 33 years (range, 31 to 35 years), 32 patients (34 hips) were still living with the original stem. Their mean modified Harris Hip Score was 86 points (range, 46 to 100) and all patients (100%) were very satisfied or satisfied with surgery. The revision incidence at 35 years considering (a) stem revision for any reason was 9.5% using KM and 4.5% using CIF; (b) stem revision for aseptic loosening was 3.1% using KM and 2.1% using CIF; and (c) reoperation or revision of any component for any reason was 45.3% using KM and 26.3% using CIF.ConclusionThe present study has demonstrated excellent survival at 35 years for a cementless double-tapered titanium fully hydroxyapatite-coated stem.Level of EvidenceLevel IV, Retrospective cohort study.  相似文献   

19.
BackgroundFor the past 2 decades, the authors have been using a long tapered cementless stem made of titanium and fully coated with hydroxyapatite for revision total hip arthroplasty. The purpose of this multicentric study is to assess clinical outcomes, radiographic outcomes, re-revision rates, and survival rates of this revision stem at a minimum 5-year follow-up.MethodsThe records of a multicentric continuous series of 335 adults undergoing revision total hip arthroplasty using the Corail revision stem (DePuy, Leeds, UK) between 2000 and 2012 were retrospectively reviewed. The Harris Hip Score, Oxford Hip Score, and Engh score were recorded. Survival was assessed using the Kaplan-Meier method and cumulative incidence function.ResultsSeventy-seven patients died with their revision stem in place, 47 could not be contacted, and 22 had stem re-revisions. This left a final cohort of 201 patients, aged 70 ± 12 years at revision surgery, with a body mass index of 26 ± 4. The Kaplan-Meier survival was 93.9% for re-revision of any component for any reason, 96.7% for re-revision of the stem for any reason, and 99.3% for re-revision of the stem for aseptic reasons. At last follow-up, the Harris Hip Score was 84.8 ± 13.1, the Oxford Hip Score was 21.0 ± 7.8, and the Engh score was 16.4 ± 6.7.ConclusionThe long tapered cementless revision stem had excellent clinical and radiographic outcomes at a minimum follow-up of 5 years. The revision stem enabled restoration of bone stock in femurs with pre-revision bone defects, confirming that the hydroxyapatite coating promotes osseointegration, even in femurs with extensive bone loss.Level of EvidenceLevel IV, retrospective cohort study.  相似文献   

20.
The objective of this retrospective study was to evaluate our results with one-stage revision using cementless femoral stem for infected hip arthroplasties. Twenty-four patients were included in the study. The acetabular component was cemented in 9 cases. In 2 patients a structured bone allograft was necessary to fill an acetabular defect. After a mean follow-up of 44.6 months, 23 patients showed no signs of infection (95.8%), the mean functional response according to the Merle d’Aubigné scale was 13.8 and the mean Harris Hip Score was 65.4. One-stage revision hip arthroplasty using cementless femoral stem was associated with a high success rate.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号