首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
《The Journal of arthroplasty》2020,35(12):3613-3620
BackgroundIncreasing global usage of cementless prostheses in total hip arthroplasty (THA) presents a challenge, especially for elderly patients. To reduce the risk of early periprosthetic femoral fractures (PFFs), a new treatment algorithm for females older than 60 years undergoing primary THA was introduced. The aim of this study was to determine the impact of the new treatment algorithm on the early risk of perioperative and postoperative PFFs and guideline compliance.MethodsA total of 2405 consecutive THAs that underwent primary unilateral THA at our institution were retrospectively identified in the period January 1, 2013-December 31, 2018. A new treatment algorithm was introduced on April 1, 2017 with female patients aged older than 60 years intended to receive cemented femoral components. Before this, all patients were scheduled to receive cementless femoral components. Demographic data, number of perioperative and postoperative PFFs, and surgical compliance were recorded, analyzed, and intergroup differences compared.ResultsThe utilization of cemented components in female patients older than 60 years increased from 12.3% (n = 102) to 82.5% (n = 264). In females older than 60 years, a significant reduction in the risk in early postoperative and intraoperative PFF after introduction of the new treatment algorithm was seen (4.57% vs 1.25%; P = .007 and 2.29% vs 0.31%; P = .02, respectively). Overall risk for postoperative and intraoperative fractures combined was also reduced in the entire cohort (4.1% vs 2.0%; P = .01).ConclusionUse of cemented fixation of the femoral component in female patients older than 60 years significantly reduces the number of PFFs. Our findings support use of cemented femoral fixation in elderly female patients.  相似文献   

2.
BackgroundTotal hip arthroplasty (THA) with subtrochanteric shortening osteotomy (SSO) is performed to manage hips with high dislocations. We compared outcomes of THA with SSO in patients with high hip dislocation resulting from childhood septic arthritis and Crowe IV developmental dysplasia of the hip (DDH).MethodsWe reviewed 60 THAs with SSO performed between May 1996 and December 2013. Thirty-one cases were classified as sequelae of childhood infection and 29 as DDH. Twenty-five hips were selected for each group after the propensity score was matched with preoperative demographics and leg length discrepancy (LLD). Clinical scores, complication and reoperation rates, radiographic results, and survivorships were compared. The mean duration of follow-up was 12.3 (range 5-22) years.ResultsThe average correction in LLD was 2.5 cm for childhood infection and 3.6 cm for DDH (P = .002). The infection group received more transfusions (mean 3.3 vs 2.0 units, P = .002), required more time for union of osteotomy site (mean 6.8 vs 5.2 months, P = .042), and reported lower Harris Hip Score (mean 85.1 vs 91.3, P = .017). Reoperations were performed in 11 (44%) previously infected hips and 3 (12%) DDHs (P = .012). Kaplan-Meier survivorship with an endpoint of revision for any reason was lower in the infection group (83.6%) than in the DDH group (100%) at 10 years (log rank, P = .040).ConclusionTHA with SSO in high hip dislocation secondary to childhood septic arthritis demonstrated less favorable clinical outcomes with increased risks of complication, compared with those performed in Crowe IV DDH with similar degree of chronic dislocation.  相似文献   

3.
《The Journal of arthroplasty》2022,37(9):1888-1894
BackgroundCemented and uncemented femoral stems have shown excellent survivorship and outcomes in primary total hip arthroplasty (THA). Cementless stems have become increasingly common in the United States; however, multiple large database studies have suggested that elderly patients may have fewer complications with a cemented stem. As conclusions from large databases may be limited due to variations in data collection, this study investigated femoral stem survivorship and complication rates based on cement status in non-database studies.MethodsPreferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines were utilized to identify articles for inclusion up until June 2021. Included articles directly compared outcomes and complications between patients undergoing primary THA without femoral stem cementing to those with cementing. Studies were excluded if they utilized large databases or consisted of patients with a preoperative diagnosis of trauma.ResultsOf the 1700 studies, 309 were selected for abstract review and nineteen for full-text review. A total of seven studies were selected. Meta-analyses indicated substantial heterogeneity between studies. There were no differences in revision rates (cementless: 5.53% vs. cemented 8.91%, P = .543), infection rates (cementless: 0.60% vs. cemented: 0.90%, P = .692), or periprosthetic fracture rates (cementless: 0.52% vs. cemented: 0.51%, P = .973) between groups.ConclusionThere is scarce literature comparing outcomes and complications between cemented and cementless femoral stems in primary elective THA without utilizing a database methodology. In our study, there were no differences in complications detected on meta-analyses. Given previous findings in database studies, additional high-quality cohort studies are required to determine if selected patients may benefit from a cemented femoral stem.  相似文献   

4.
《The Journal of arthroplasty》2021,36(9):3269-3274
BackgroundIn revision total hip arthroplasty (THA) cases with preserved femoral metaphyseal bone, tapered proximally porous-coated “primary” femoral stems may be an option. The objective of this study was to compare outcomes of patients with Paprosky I or II femoral bone loss undergoing revision THA with either a primary metaphyseal-engaging cementless stem or a revision diaphyseal-engaging stem.MethodsThis was a retrospective analysis of 70 patients with Paprosky I or II femoral bone loss who underwent femoral revision. 35 patients who were revised using a primary cementless femoral stem were compared with 35 patients who underwent femoral revision using a revision diaphyseal-engaging stem. The groups were similar regarding age, gender, body mass index, and American Society of Anesthesiologists. Clinical and radiographic outcomes and complications were compared over an average follow-up of 2.9 years (SD 1.4).ResultsRevision THA was most commonly performed for periprosthetic joint infection (N = 27, 38.6%). The groups were similar with regards to Paprosky femoral classification (P = .56), length of stay (P = .68), discharge disposition (P = .461), operative time (P = .20), and complications (P = .164). There were no significant differences between primary and revision femoral stem subsidence (0.12 vs. 0.75 mm, P = .18), leg length discrepancy (2.3 vs. 4.05 mm, P = .37), and Hip Disability and Osteoarthritis Outcome Score Jr (73.1 [SD 21.1] vs. 62.8 [SD 21.7], P = .088). No patient underwent additional revision surgery involving the femoral component.ConclusionUse of modern primary cementless femoral stems is a viable option for revision hip arthroplasty in the setting of preserved proximal femoral metaphyseal bone. Outcomes are not inferior to those of revision stems and offer potential benefits.  相似文献   

5.
《The Journal of arthroplasty》2020,35(10):2926-2930
BackgroundMany studies have analyzed the outcomes of total hip arthroplasty (THA) after failed intertrochanteric fracture fixation, but not after healed fracture. The objective is to investigate the influence of a prior healed intertrochanteric fracture fixation on the outcomes of a subsequent THA for osteoarthritis.MethodsThis is a matched retrospective cohort study of THA between 43 patients who suffered a prior intertrochanteric fracture successfully managed with internal fixation and 43 patients without prior hip fracture. Mean age was 73.6 vs 74.2 years. A conventional cementless THA was used in both groups. Functional outcome was assessed by the Harris hip score (HHS) and reduced Western Ontario and McMaster Universities Osteoarthritis Index questionnaire. Radiological assessment was also performed.ResultsMean follow-up was 6.6 (range, 5-8) years. The mean operative time and blood transfusion rate were significantly higher in the fracture group (P = .001), but there was no significant difference in the length of stay. HHS significantly improved in both groups. At final follow-up, HHS was significantly higher in nonfracture group (P = .008), but the rate of patients with excellent and good outcomes was similar (P = .616). Western Ontario and McMaster Universities Osteoarthritis Index score at the final follow-up was not different between groups (P = .058). Complication rate was similar between groups. There were no revisions, dislocations, or loose implants in the study group.ConclusionCementless THA provided successful functional outcomes and implant durability at medium term in patients treated for osteoarthritis following healed intertrochanteric fracture fixation, comparable to those without prior fracture who underwent primary THA. Surgical complexity and complication rate were low.  相似文献   

6.
《The Journal of arthroplasty》2022,37(8):1631-1635
BackgroundDuring revision total hip arthroplasty (THA), a constrained acetabular liner (CAL) may be inserted to enhance hip stability. It is unclear, however, whether cementation of a CAL into a retained cup offers an advantage compared to revision of the acetabular cup and insertion of an uncemented CAL. The purpose of our study was to compare outcomes and survivorship between the 2 methods.MethodsWe identified a total of 177 patients who underwent revision THA with a specific CAL at our center between July 2004 and May 2019 (114 cup revisions and insertion of an uncemented CAL, 63 cementations of a CAL into a retained cup). Kaplan-Meier (KM) survival analysis was performed for implant survival free from aseptic failure of the CAL for both cohorts.ResultsThe average follow-up time was 7.2 and 7.02 years for the cemented and uncemented cohort, respectively (P = .55). Five patients (7.93%) in the cemented CAL group experienced failure of the CAL, whereas 10 patients (8.77%) in the uncemented CAL cohort experienced failure (P = .21). Kaplan-Meier (KM) survival analysis demonstrated comparable survivorship at 10 years (P = .055).ConclusionThe results of our study suggest comparable survivorship between cementing a CAL into a retained cup and inserting an uncemented CAL in a revised acetabular cup. As a result of these findings along with the benefits associated with cementing a CAL, we encourage surgeons to readily consider this option in the management of recurrent instability.  相似文献   

7.
《The Journal of arthroplasty》2021,36(11):3667-3675.e4
BackgroundActive patients with displaced femoral neck fractures are often treated with total hip arthroplasty (THA). However, optimal femoral fixation in these patients is controversial. The purpose of this study was to compare early complication and readmission rates in patients with hip fracture treated with THA receiving cemented vs cementless femoral fixation.MethodsThe National Readmissions Database was queried to identify patients undergoing primary THA for femoral neck fracture from 2016 to 2017. Postoperative complications and unplanned readmissions at 30, 90, and 180 days were compared between patients treated with cemented and cementless THA. Univariate and multivariate analyses were performed to compare differences between groups and account for confounding variables.ResultsOf 17,491 patients identified, 4427 (25.3%) received cemented femoral fixation and 13,064 (74.7%) cementless. The cemented group was significantly older (77.2 vs 71.1, P < .001), had more comorbidities (Charlson comorbidity index: 4.44 vs 3.92, P < .001), and had a greater proportion of women (70.5% vs 65.2%, P < .001) compared with the cementless group. On multivariate analysis, cemented fixation was associated with reduced rates of periprosthetic fracture (odds ratio: 0.052, 95% confidence interval: 0.003-0.247, P = .004) at 30 days but similar readmission rates at 30, 90, and 180 days (odds ratio range: 1.012-1.114, P > .05) postoperatively compared with cementless fixation. Cemented fixation was associated with greater odds of medical complications at 180 days postoperatively (odds ratio:: 1.393, 95% confidence interval: 1.042-1.862, P = .025).ConclusionCemented femoral fixation was associated with a lower short-term incidence of periprosthetic fractures, higher incidence of medical complications, and equivalent unplanned readmission rates within 180 days postoperatively compared with cementless fixation in patients undergoing THA for femoral neck fracture.Level of EvidenceLevel III.  相似文献   

8.
《The Journal of arthroplasty》2021,36(12):3922-3927.e2
BackgroundThere has been an increase in hip arthroscopy (HA) over the last decade. After HA, some patients may ultimately require a total hip arthroplasty (THA). However, there is a scarcity of research investigating the outcomes in patients undergoing THA with a history of ipsilateral HA.MethodsThe PearlDiver research program (www.pearldiverinc.com) was queried to capture all patients undergoing THA between 2015 and 2020. Propensity matching was performed to match patients undergoing THA with and without a history of ipsilateral THA. Rates of 30-day medical complications, 1-year surgical complications, and THA revision were compared using multivariate logistic regression. Kaplan-Meier analysis was conducted to estimate survival probabilities of each of the groups with patients undergoing THA .ResultsAfter propensity matching, cohorts of 1940 patients undergoing THA without prior HA and 1940 patients undergoing a THA with prior HA were isolated for analysis. The mean time from HA to THA was 1127 days (standard deviation 858). Patients with a history of ipsilateral HA had an increased risk for dislocation (odds ratio [OR] 1.56, P = .03) and overall decreased implant survival within 4 years of undergoing THA (OR 1.53; P = .05). Furthermore, our data demonstrate the timing of previous HA to be associated with the risk of complications, as illustrated by the increased risk for dislocation (OR 1.75, P = .03), aseptic loosening (OR 2.18, P = .03), and revision surgery at 2 (OR 1.92, P = .02) and 4 years (OR 2.05, P = .01) in patients undergoing THA within 1 year of HA compared twitho patients undergoing THA more than 1 year after HA or with no previous history of HA.ConclusionPatients undergoing THA after HA are at an increased risk for surgical complications, as well as the need for revision surgery.  相似文献   

9.
《The Journal of arthroplasty》2019,34(9):2016-2021
BackgroundIncrease in acetabular cup abduction in total hip arthroplasty (THA) using conventional polyethylene is associated with greater linear wear. Whether this relationship holds true for highly crosslinked liners, particularly with long-term follow-up, is still controversial. The effect of liner thickness on wear of highly cross-linked liners also remains to be clarified.This study sought to determine (1) the long-term clinical and radiological performance of highly cross-linked polyethylene in THA and (2) the effect of acetabular component positioning, polyethylene thickness, and patient demographics on wear.MethodsNinety-three THAs using a 28-mm hip ball, single brand of highly cross-linked polyethylene liner, and cementless cup were performed in 87 patients. Clinical outcomes were evaluated using the Harris Hip Score and need for revision surgery. Linear and volumetric wear, presence of osteolysis, and cup abduction angle were assessed.ResultsThe mean age at operation was 51.4 years. The mean duration of follow-up was 12.7 years (10-16 years). Patients aged >50 years had higher rates of linear wear than those aged <50 years (P = .015). Positive correlation was found between cup abduction angle (P = .014) and cup version (P = .035) with a linear wear rate. Thinner liners (≤7 mm) had similar rates of linear and volumetric wear as thicker liners (≥8 mm) (P = .447).ConclusionThis is the only study to demonstrate a positive significant relationship between cup abduction angle and version with linear wear rate in THA with at least 10 years of follow-up. Liner thickness was not found to affect wear rates.  相似文献   

10.
BackgroundMalposition of the acetabular component during total hip arthroplasty (THA) is associated with increased risk of dislocation, reduced range of motion, and accelerated wear. The purpose of this study is to compare cup positioning with a portable, accelerometer-based hip navigation system and conventional surgical technique.MethodsIn a prospective, randomized, clinical study, cups were implanted with a portable, accelerometer-based hip navigation system (navigation group; n = 55) or conventional technique (conventional group; n = 55). THA was conducted in the lateral position and through posterior approach. The cup position was determined postoperatively on pelvic radiograph and computed tomography scans.ResultsAn average cup abduction of 39.2° ± 4.6° (range, 27° to 50°) and an average cup anteversion of 14.6° ± 6.1° (range, 1° to 27.5°) were found in the navigation group, and an average cup abduction of 42.9° ± 8.0° (range, 23° to 73°) and an average cup anteversion of 11.6° ± 7.7° (range, −12.1° to 25°) in the conventional group. A smaller variation in the navigation group was indicated for cup abduction (P = .001). The deviations from the target cup position were significantly lower in the navigation group (P = .001, .016). While only 37 of 55 cups in the conventional group were inside the Lewinnek safe zone, 51 of 55 cups in the navigation group were placed inside this safe zone (P = .006). The navigation procedure took a mean of 10 minutes longer than the conventional technique.ConclusionUse of the portable, accelerometer-based hip navigation system can improve cup positioning in THA.  相似文献   

11.
BackgroundPreoperative templating for total hip arthroplasty (THA) on digital radiography can be achieved using templating software or hybrid methods (acetate templates overlaid on digital images). No studies have examined templating with a mobile phone. We evaluated the accuracy and reproducibility of a new digital templating method using the picture archiving and communication system (PACS) and iPhone, compared with the hybrid method for cementless THA.MethodsA total of 113 hip radiographs were retrospectively templated by three observers. For the digital method, a circle was drawn on the acetabulum using PACS to represent the cup. The photograph of the computer screen was taken with an iPhone and imported into the Keynote presentation software. The femoral stem was then templated with transparent digital templates, which had been digitized from acetate templates. For the hybrid method, an acetate template was placed over the onscreen digital radiographs. Templated results were compared with the actual components used.ResultsThe digital method was more accurate than the hybrid method to predict ±1 size of femoral stem [93.8% (106 hips) vs 84.1% (95 hips), P = .032] and offset [90.3% (102 hips) vs 75.2% (85 hips), P = .004)]. The accuracies of digital and hybrid techniques were comparable with predict ±1 size for acetabular cup [92.9% (105 hips) vs 89.4% (101 hips), P = .483] and neck length [98.2% (111 hips) vs 96.5% (109 hips), P = .683]. Both techniques had substantial to almost perfect agreement for intraobserver and interobserver reliability.ConclusionDigital templating using PACS and iPhone is accurate and reproducible for predicting implant size of cementless THA.  相似文献   

12.
BackgroundHip fracture in older patients leads to high morbidity and mortality. Patients who are treated surgically but fail acutely face a more complex operation with conversion total hip arthroplasty (THA). This study investigated mortalities and complications in patients who experienced failure within one year following hip fracture surgery requiring conversion THA.MethodsPatients aged 60 years or more undergoing conversion THA within one year following intertrochanteric or femoral neck fracture were identified and propensity-matched to patients sustaining hip fractures treated surgically but not requiring conversion within the first year. Patients who had two-year follow-up (91 conversions; 247 comparisons) were analyzed for 6-month, 12-month, and 24-month mortalities, 90-day readmissions, surgical complications, and medical complications.ResultsNonunion and screw cutout were the most common indications for conversion THA. Mortalities were similar between groups at 6 months (7.7% conversion versus 6.1% nonconversion, P = .774), 12 months (11% conversion versus 12% nonconversion, P = .999), and 24 months (14% conversion versus 22% nonconversion, P = .163). Survivorships were similar between groups for the entire cohort and by fracture type. Conversion THA had a higher rate of 90-day readmissions (14% versus 3.2%, P = .001), and medical complications (17% versus 6.1%, P = .006). Inpatient and 90-day orthopaedic complications were similar.ConclusionConversion THA for failed hip fracture surgery had comparable mortality rates to hip fracture surgery, with higher rates of perioperative medical complications and readmissions. Conversion THA following hip fracture represents a potential “second hit” that both surgeons and patients should be aware of with initial decision-making.  相似文献   

13.
BackgroundModular stems are useful for total hip arthroplasty (THA) in anatomically difficult dysplasia. Here, we present mean 6.8-year outcomes of cementless primary THA using S-ROM-A (modified modular stem for Asian patients) femoral prosthesis in anatomically difficult cases.MethodsCharts of 373 patients (461 hips) undergoing THA (mean age, 58 years) were reviewed for clinical evaluation of modified Merle d’Aubigné-Postel score and Kaplan-Meier survivorship with revision for any reason as the end point. For radiographic analysis, 331 patients (412 hips) followed up for ≥5 years were included. Bearing couples were metal-on-metal (n = 145), metal-on-polyethylene (n = 120), and ceramic-on-polyethylene (n = 147). Radiography and multiplanar computed tomography were performed.ResultsNo postoperative dislocation or deep infection occurred. Mean modified Merle d’Aubigné-Postel score improved significantly (10.9 points preoperatively, 16.7 points at last follow-up; P < .001). Cumulative 5- and 10-year stem survival rates were 100% and 84%, respectively (95% confidence interval, 75%-93%). All stems were classified as bone ingrown fixation. Osteolysis occurred in metal-on-metal (42.8%) and metal-on-polyethylene (15.8%) groups. Mean time to osteolysis was ~3 years, with no significant difference between 3 groups (P = .264). In logistic regression, lower cup inclination angle was significantly associated with osteolysis (odds ratio, 0.914; 95% confidence interval, 0.84-0.99; P = .029).ConclusionS-ROM-A femoral prosthesis achieved excellent midterm fixation, and the modular system was useful in primary THA with severe deformity. Bearing couples are potentially associated with adverse reactions to metal debris. S-ROM-A with ceramic-on-polyethylene bearing couples may be an option for anatomically difficult THA.  相似文献   

14.
BackgroundThis study aimed to investigate the risk factors for dislocation in patients diagnosed with developmental dysplasia of the hip (DDH) who underwent total hip arthroplasty.MethodsWe retrospectively reviewed 40 patients who developed dislocation and compared them with 400 patients in the control group without hip instability. Patients-, surgery-, and implant-related factors were investigated. Risk factors were evaluated using multivariate logistic regression.ResultsThe mean follow-up period was 32.3 months. The mean time to dislocation was 4.4 months. There were 7 men (17.5%) and 33 women (82.5%) in the dislocation group and 83 men (20.7%) and 317 women (79.3%) in the control group (P = .627). Diabetes mellitus (DM; P = .032) and history of previous hip surgery for DDH were associated with dislocation (P < .001). The subtrochanteric shortening osteotomy (P = .001), acetabular inclination (P = .037), acetabular anteversion (P < .001), femoral head size (P < .001), and postoperative infection (P = .003) were associated with dislocation. Major predictors of hip dislocation after total hip arthroplasty in patients with DDH were previous hip surgery (odds ratio [OR], 6.76; 95% confidence interval [CI], 1.86-24.6; P = .004), high hip center (OR, 2.90; 95% CI, 1.31-6.38; P = .008), DM (OR, 2.68; 95% CI, 1.06-6.80; P = .037), and acetabular inclination (OR, 2.62; 95% CI, 1.09-6.26; P = .03).ConclusionPatients with DM and previous hip surgery should be informed about increased dislocation rates. Using a larger head diameter and restoration of the true hip rotation center are essential to prevent hip dislocation in these patients. Furthermore, accurate positioning of the acetabular inclination and anteversion are also important.  相似文献   

15.
BackgroundThe rate of failure of cemented and cementless total hip arthroplasty (THA) in younger patients is higher than that in elderly patients. The purpose of this study is to document the long-term clinical results of THA with the so-called third-generation cementing and the results of second-generation cementless THA in patients <50 years of age.MethodsThis study included 106 patients who had had bilateral THA with a cemented stem in one hip and a cementless stem in the other. There were 78 men and 28 women. Their mean age was 47 years (range, 21-49). The average follow-up duration was 31 years (range, 30-32.5).ResultsThere were similar mean Harris Hip Scores (90 versus 91 points) between the groups at the final follow-up. Forty-six acetabular components (43%) in the cemented group and 48 acetabular components (45%) in the cementless group were revised. Five femoral components (5%) in the cemented group and 4 femoral components (4%) in the cementless group were revised. Survivorship of the acetabular component at 30.8 years was similar in both groups (57% in the cemented group versus 55% in the cementless group). Survivorship of the femoral component at 30.8 years was also similar in both groups (95% in the cemented group versus 96% in the cementless group).ConclusionLong-term fixation of the cemented or cementless femoral stem was outstanding. There was a high rate of the acetabular component revision due to conventional polyethylene wear and periacetabular osteolysis in both hybrid and fully cementless THA groups.  相似文献   

16.
BackgroundThe American Academy of Orthopaedic Surgeons guidelines report moderate evidence for cementing femoral stems for hip fractures, mainly derived from hemiarthroplasty literature. This is the first large, nonregistry study examining the influence of femoral fixation, implant type, patient characteristics, and radiographic factors on outcomes after total hip arthroplasty (THA) for acute femoral neck fractures.MethodsA multicenter retrospective study was performed of 709 THA cases (199 cemented, 510 cementless) for femoral neck fractures from 2006 to 2020 at three large academic institutions. Demographics, perioperative characteristics, and radiographs were reviewed. Kaplan-Meier survivorship curves were generated for multiple outcomes. Univariate and multivariate analyses were performed with P ≤ .05 denoting significance.ResultsCementless stems had a higher all-cause aseptic femoral revision rate (5.1 versus 0.5%, P = .002) and periprosthetic femoral fracture rate (4.3 versus 0%, P = .001). Each successive Dorr type had a higher fracture rate with cementless implants: 2.3%, 3.7%, and 15.9% in Dorr A, B, and C, respectively (P < .001). Logistic regression analyses confirmed that cementless stems (P = .02) and Dorr C bone (P = .001) are associated with periprosthetic fractures; collared implants and prophylactic cables did not protect against fractures. There was no difference in rates of dislocation, septic revision, or mortality between groups.ConclusionCementless stems during THA for femoral neck fractures have a higher aseptic femoral revision rate, specifically for periprosthetic fractures. Dorr C bone was particularly prone with an alarmingly high fracture rate. All fractures occurred in cementless cases, suggesting that cemented stems may minimize this complication.Level of EvidenceIII.  相似文献   

17.
《The Journal of arthroplasty》2020,35(9):2529-2536
BackgroundThe aim of this study is to compare clinical results of Crowe type III-IV developmental dysplasia of the hip (DDH) patients who underwent total hip arthroplasty with either trochanteric slide osteotomy (TSO) or subtrochanteric shortening osteotomy (SSO).MethodsThe patients who underwent cementless total hip arthroplasty with femoral shortening osteotomy due to Crowe type III/IV DDH between 2004 and 2014 and completed at least 5 years of follow-up were retrospectively analyzed. The patients were grouped according to the type of shortening osteotomy as either TSO or SSO. Preoperative and postoperative clinical evaluation included Harris Hip Score, Visual Analogue Scale pain, leg length discrepancy, and the presence of Trendelenburg sign. The clinical outcome measures and complication rates were compared in terms of osteotomy type.ResultsThe TSO group consisted of 34 patients (43 hips) and the SSO group consisted of 40 patients (51 hips). The SSO group (96.1%) had a slightly higher 5-year survival of the implant compared to TSO (93%) without statistical significance (P = .18). No significant difference was detected between the groups in terms of clinical outcomes. Complication rates did not significantly differ between the groups except for the lack of bony union which was significantly higher in TSO (P = .006) but this difference did not transform into clinical significance since 5 of 6 patients who did not have a bony union in the TSO group were symptom-free with a fibrous union.ConclusionTSO and SSO provide similar clinical outcomes at mid-term follow-up in the management of Crowe III-IV DDH by cementless total hip arthroplasty. Both techniques can be used safely depending on the surgeon’s preference.Level of EvidenceLevel III, Therapeutic, Case-control study.  相似文献   

18.
BackgroundRecent studies indicate a decreased risk of periprosthetic femoral fractures (PFFs) in cementless total hip arthroplasty (THA) for short compared to straight stems. However, the results are still inconclusive. Therefore, we retrospectively investigated the rate of PFFs within the first year between cementless short and straight stem THA.MethodsA 1:1 propensity score matching of 3,053 THAs was performed. Two groups including 1,147 short stem THAs implanted through a minimally invasive antero-lateral approach and 1,147 straight stem THAs implanted through a transgluteal Hardinge approach were matched. The rates of PFFs and fracture patterns were compared between both stem types. Risk factors for PFFs were analyzed by multivariate regression analyses.ResultsThe overall rate of PFFs was 1.7% in short stem THA and 3.2% in straight stem THA (P = .015). Postoperatively detected Vancouver A fractures occurred significantly more often in straight stem THA (P = .002), while the occurrence Vancouver B fractures did not differ significantly (P = .563). The risk of PFFs was significantly increased for women in straight stem THA (Odds ratio (OR) 2.620; Confidence Interval (CI) 1.172-5.856; P = .019). Increasing age showed a significantly increased odds ratio in short stem (OR 1.103; CI 1.041-1.169, P < .001) and straight stem THA (OR 1.057; CI 1.014-1.101, P = .008).ConclusionShort stem THA reduces Vancouver Type A PFFs in the trochanteric region compared to straight stem THA, while Vancouver Type B fractures are comparable. Increasing age is a significant risk factor for both stem types, while the risk for PFFs in women was only significantly increased in the straight stem group.  相似文献   

19.

Background

Total hip arthroplasty (THA) for severe developmental dysplasia of the hip (DDH) is a technically demanding procedure for arthroplasty surgeons, and it is often difficult to reduce the hip joint without soft tissue release due to severe flexion contracture. We performed two-stage THAs in irreducible hips with expected lengthening of the affected limb after THA of over 2.5 cm or with flexion contractures of greater than 30 degrees in order to place the acetabular cup in the true acetabulum and to prevent neurologic deficits associated with acute elongation of the limb. The purpose of this study is to evaluate the outcomes of cementless THA in patients with severe DDH with a special focus on the results of two-stage THA.

Methods

Retrospective clinical and radiological evaluations were done on 17 patients with Crowe type III or IV developmental DDH treated by THA. There were 14 women and 3 men with a mean age of 52.3 years. Follow-ups averaged 52 months. Six cases were treated with two-stage THA followed by surgical hip liberalization and skeletal traction for 2 weeks.

Results

The mean Harris hip score improved from 40.9 to 89.1, and mean leg length discrepancy (LLD) in 13 unilateral cases was reduced from 2.95 to 0.8 cm. In the patients who underwent two-stage surgery, no nerve palsy was observed, and the single one-stage patient with incomplete peroneal nerve palsy recovered fully 4 weeks postoperatively.

Conclusions

The short-term clinical and radiographic outcomes of primary cementless THA for patients with Crowe type III or IV DDH were encouraging. Two-stage THA followed by skeletal traction after soft tissue release could provide alternative solutions to the minimization of limb shortenings or LLD without neurologic deficits in highly selected patients.  相似文献   

20.
BackgroundDespite promising results at the mid-term followup, several aspects of conversion of the fused hip to total hip arthroplasty (THA) remain controversial. The aim of this study was to evaluate clinical and radiological outcomes with a minimum 5-year followup in patients who underwent conversion of the fused hip to THA.MethodsFifty-seven patients (59 hips) were evaluated. The Harris Hip Score (HHS), range of motion (ROM), and the Visual Analogue Scale (VAS) were used to assess hip function and low back pain. Subjective satisfaction with surgery and the presence of the Trendelenburg sign was also evaluated. Radiological assessment was performed pre- and postoperatively to evaluate loosening and heterotopic ossification (HO).ResultsAfter a mean followup of 13.0 ± 6.2 years, HHS and VAS significantly improved from 46.0 ± 16.7 to 80.8 ± 18.8 and from 4.4 ± 1.5 to 2.1 ± 1.4 (both P < .001), respectively. Twenty-three patients (40.4%) had a positive Trendelenburg sign, and HOs were found in 29 cases (49.1%). An overall 29.8% complication rate was noted. Smoking habits and rheumatoid arthritis were predictive of Trendelenburg sign (P = .046 and P = .038, respectively). Implant survival rate as the end point was 98.7 ± 1.3% at 5 years, 92.4 ± 3.3% at 10 years, 82.1 ± 5.7% at 15 years, and 73.4 ± 8.0% at 20 and 25 years. A worse cumulative implant survival rate was noted in patients who underwent previous hip surgery, defined as any hip operation before fusion (P = .005).ConclusionConversion of the fused hip to hip arthroplasty provides high levels of hip functionality and satisfaction with surgery at long-term followup. An implant survival rate higher than 70% can be expected 25 years postoperatively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号