共查询到20条相似文献,搜索用时 15 毫秒
1.
Objectives. We prospectively compared myocardial uptake of thallium-201 ( 201Tl) at rest with rest technetium-99m ( 99mTc) sestamibi uptake in the same patients, using quantitative single-photon emission computed tomography (SPECT). Background. Because of only slightly delayed redistribution, 99mTc-sestamibi uptake at rest may be less than 201Tl uptake, thereby underestimating the extent of viability. Methods. Twenty patients (2.25 stenoses per patient) with a mean left ventricular ejection fraction of 33 ± 2% underwent early and 3-h delayed rest 201Tl SPECT, rest 99mTc-sestamibi SPECT and two-dimensional echocardiography. Results. The 280 scan segments were classified as either a normal, mild reduction in viability, defined as delayed 201Tl uptake ≤75% and ≥5%, or a severe reduction in viability, defined as delayed 201Tl uptake <50%. Mild and severe defects were further classified as fixed or having rest 201Tl redistribution. Comparisons by patients were made using repeated measures analysis of variance and Dunnett's multiple comparisons test to compare 99mTc-sestamibi with initial rest 201Tl and delayed 201Tl uptake. Twenty patients had at least one mild fixed defect (95 total segments). The average percent uptake in these defects for initial 201Tl, delayed 201Tl and 99mTc-sestamibi was 62.5 ± 2.7%, 63.1 ± 7.1% and 67.3 ± 9.7%, respectively (p = NS). Twelve patients (27 segments) had mild redistribution defects on serial rest 201Tl imaging. The average percent uptake was 61.6 ± 5.2% for initial 201Tl, 67.0 ± 9.1% for delayed 201Tl and 67.7 ± 12.4% for 99mTc-sestamibi defects. Technetium-99m sestamibi uptake was not significantly different than that for delayed 201Tl but was significantly greater than initial 201Tl uptake. Seventeen patients (52 segments) had severe fixed 201Tl defects. The average percent uptake was 38.9 ± 7.3% for initial 201Tl, 38.3 ± 12.2% for delayed 201Tl and 42.7 ± 14.2% for 99mTc-sestamibi defects in these patients (p = NS). Ten patients (19 segments) had severe redistribution defects on rest 201Tl imaging. The average percent uptake was 37.0 ± 8.5% for initial 201Tl, 42.9 ± 8.6% for delayed 201Tl and 44.5 ± 11.3% for 99mTc-sestamibi defects. As was seen for mild 201Tl redistribution defects, 99mTc-sestamibi uptake was significantly higher than initial 201Tl uptake, but not significantly different than delayed 201Tl uptake in these severe defects. Conclusions. Technetium-99m sestamibi uptake after injection at rest is comparable to 201Tl uptake after injection at rest in patients with severe coronary artery disease and left ventricular dysfunction, suggesting comparable worth for viability assessment. 相似文献
2.
Defect size on myocardial tomograms was measured in 30 patients who underwent 2 separate studies, 1 with thallium-201 (TI-201), the other with technetium-99m-methoxyisobutyl isonitrile (MIBI). A group of 15 patients with myocardial infarction was studied at rest and received both tracers on the same day. The other 15 patients had documented coronary artery disease. They were were given injections of TI-201 at peak exercise and underwent imaging immediately after exercise and again 4 hours later. They then received a dose of MIBI for imaging at rest. A week later they underwent a second exercise test with the same work load and received a second dose of MIBI. Defect size on single-photon emission computed tomographic images was measured and repeated twice. Results were expressed in percentage of the volume of the whole myocardium. Reproducibility of the defect size measurement was high for TI-201 (r = 0.978; SEE = 1.59) as well as for MIBI (r = 0.981; SEE = 0.80). In patients with coronary artery disease the mean size of the defects was significantly larger with TI-201 than with MIBI at exercise (6.7 +/- 5.2 vs 4.6 +/- 5.2%, respectively, p less than 0.05) and at redistribution (5.1 +/- 4.4 vs 2.8 +/- 3.2%, respectively, p less than 0.05), where no difference was seen in patients with myocardial infarction studied only at rest (11.2 +/- 10.4 vs 12.0 +/- 11.5%, respectively, p = not significant). Smaller MIBI defect sizes, when compared with TI-201, in the exercise and redistribution studies were not due to technical artefacts since there was no difference when they were compared at rest. 相似文献
3.
Thallium-201 (201Tl) is a well-established radionuclide used in myocardial perfusion imaging for assessing the presence and prognostic significance of coronary artery disease. Recently, technetium-99m hexakis-2-methoxyisobutyl isonitrile (99mTc-sestamibi) has become available for the same diagnostic and prognostic procedures. This discussion compares the imaging characteristics and clinical applications of 201Tl with those of 99mTc-sestamibi. There is a strong diagnostic concordance between the 2 agents in symptomatic patients. Various comparative clinical trials have shown in numerous patients that both agents have a similar diagnostic yield in both planar and single-photon emission computed tomography (SPECT) imaging. Because of better image quality of the 99mTc agent, there is a trend toward better specificity and normalcy rate, in comparison to 201Tl. However, when using reinjection imaging protocols, 201Tl retains a unique place as an imaging agent to identify viable myocardium. 相似文献
4.
First-pass radionuclide ventriculography followed by myocardial SPECT with technetium-99m methoxy isobutyl isonitrile (Tc-99m MIBI) was performed on 12 patients with suspected coronary artery disease at rest and during exercise. Left ventricular wall motion and myocardial perfusion were assessed simultaneously and compared on a segment-by-segment basis. Segmental agreement between Tc-99m MIBI and Tl-201 with regard to the presence of perfusion defects was 95% (57/60) at rest and 93% (37/40) during exercise. With respect to the assessment of myocardial ischemia and/or infarction, abnormalities in regional wall motion agreed with the presence of myocardial perfusion defects in 18 out of 21 segments (86%). Simultaneous evaluation of regional wall motion and myocardial perfusion by Tc-99m MIBI may provide useful information for the assessment of myocardial ischemia. 相似文献
5.
Technetium-99m (Tc-99m) teboroxime is a new perfusion tracer that is highly extracted and rapidly cleared by the myocardium. To determine the feasibility of Tc-99m teboroxime imaging in the diagnosis of patients with suspected coronary artery disease, 30 patients underwent single photon emission computed tomography imaging with Tc-99m teboroxime (25.2 +/- 1 mCi) at peak exercise and again 60 min later at rest. All patients underwent either a thallium stress test (n = 26) or automated quantitative coronary arteriography (n = 25), or both, without intervening revascularization or infarction. Images were reviewed by two investigators who had no knowledge of clinical data. Coronary lesions with greater than or equal to 50% diameter narrowing by quantitative coronary arteriography were considered significant. Both thallium and Tc-99m teboroxime detected disease in all patients with two or three vessel disease. One vessel disease was detected with Tc-99m teboroxime in 9 of 10 patients and with thallium in 8 of 10 (p = NS). In patients without angiographically significant disease. Tc-99m teboroxime demonstrated normal perfusion in six of eight patients and thallium in three of five (p = NS). Overall, when presence or absence of disease detected by Tc-99m teboroxime or thallium was compared with quantitative coronary arteriography, there was no difference between Tc-99m teboroxime and thallium. These results suggest that Tc-99m teboroxime is comparable to thallium as an imaging agent. The rapid biologic half-life, 5.3 min, allows studies to be completed in 60 to 90 min. 相似文献
6.
Technetium-99m (Tc-99m) sestamibi is a new myocardial perfusion imaging agent that offers significant advantages over thallium-201 (Tl-201) for myocardial perfusion imaging. The results of the current clinical trials using acquisition and processing parameters similar to those for Tl-201 and a separate (2-day) injection protocol suggest that Tc-99m sestamibi and Tl-201 single photon emission computed tomography (SPECT) provide similar information with respect to detection of myocardial perfusion defects, assessment of the pattern of defect reversibility, overall detection of coronary artery disease (CAD) and detection of disease in individual coronary arteries. Tc-99m sestamibi SPECT appears to be superior to Tc-99m sestamibi planar imaging because the former provides a higher defect contrast and is more accurate for detection of disease in individual coronary arteries. Research is currently under way addressing optimization of acquisition and processing of Tc-99m sestamibi studies and development of quantitative algorithms for detection and localization of CAD and sizing of transmural and nontransmural myocardial perfusion defects. It is expected that with the implementation of the final results of these new developments, further significant improvement in image quality will be attained, which in turn will further increase the confidence in image interpretation. Development of algorithms for analysis of end-diastolic myocardial images may allow better evaluation of small and nontransmural myocardial defects. Furthermore, gated studies may provide valuable information with respect to regional myocardial wall motion and wall thickening. With the implementation of algorithms for attenuation and scatter correction, the overall specificity of Tc-99m sestamibi SPECT should improve significantly because of a substantial decrease in the occurrence of attenuation-related image artifacts.(ABSTRACT TRUNCATED AT 250 WORDS) 相似文献
7.
Single-photon emission computed tomographic imaging with technetium-99m teboroxime during exercise has been found to be feasible and the results correlate with those obtained with thallium-201. This study examined the feasibility of this technique and compared tomographic imaging with technetium-99m teboroxime during adenosine-induced coronary hyperemia with thallium-201 imaging. With the patient positioned on the imaging table, adenosine was infused at a rate of 140 micrograms/kg per min for 6 min. At 4 min, 20 to 25 mCi (740 to 925 MBq) of technetium-99m teboroxime was injected intravenously and imaging was started as soon as the infusion was completed with use of a 180 degrees anterior arc and 32 stops at 10 s/stop (total imaging time 7.8 min). Rest images were obtained 60 to 90 min later with use of a similar dose of technetium-99m teboroxime. Exercise tomographic thallium images were obtained within 2 weeks of the teboroxime studies. In the 20 patients studied, the teboroxime images were normal in 2 (50%) of 4 normal subjects and abnormal in 15 (94%) of 16 patients with coronary artery disease; 4 of the 15 had a fixed defect and 11 a reversible defect. There was agreement between teboroxime and thallium studies in 16 patients (80%), in 319 (80%) of 400 segments and in 50 (83%) of 60 vascular segments (p less than 0.05). In two normal subjects, an apparent fixed defect involving the inferior wall was seen on the teboroxime but not the thallium images and was thought to be due to an attenuation artifact secondary to extracardiac activity in the left lobe of the liver.(ABSTRACT TRUNCATED AT 250 WORDS) 相似文献
8.
New radiopharmaceuticals permit simultaneous assessment of myocardial perfusion and left ventricular function using a single tracer injection. The purpose of this study was to quantitate the relation between myocardial perfusion and function at rest and during exercise in patients with documented coronary artery disease (CAD). A rest first-pass radionuclide angiocardiogram (RNA) was recorded in 51 patients with CAD during injection of 10 mCi of technetium-99m (Tc-99m) sestamibi, and tomographic perfusion images were obtained 60 minutes later. A treadmill test was then performed, and on attainment of an exercise end point a second first-pass RNA was recorded with 30 mCi of Tc-99m sestamibi. Tomographic images reflecting myocardial perfusion during exercise were obtained 1 hour later. Tomographic perfusion defect size, quantified using modifications of the Cedars-Sinai program, correlated directly with end-systolic volume and inversely with ejection fraction at rest and during exercise. However, perfusion defect size often varied widely in patients with similar left ventricular function. This independence between measurements of perfusion and function suggests that simultaneous assessment of the 2 physiologic variables could improve the diagnostic and prognostic information of radionuclide tests. 相似文献
9.
Technetium-99m (TC-99m)-teboroxime is a new myocardial perfusion imaging agent. The purpose of this prospective study was to compare Tc-99m-teboroxime with thallium-201 imaging after the administration of dipyridamole. Thirty patients referred for the evaluation of chest pain were studied with both thallium-201 and Tc-99m-teboroxime dipyridamole scans (mean interval 2 days). Dipyridamole was administered at 0.142 mg/kg/min for 4 minutes. Planar imaging (3 standard views) was obtained at 5 and 240 minutes after the injection of 2.2 mCi of thallium-201. Tc-99m-teboroxime (18 to 25 mCi) was injected after dipyridamole infusion. A second injection, at rest, was repeated 4 hours later. Planar imaging (3 standard views of 1 minute/view for the first 2 views, and 90 seconds for the last view) was obtained 2 minutes after Tc-99m-teboroxime injection. Blinded reading was performed by 3 observers. Thallium-201 showed perfusion defects in 182 myocardial segments corresponding to 33 of 45 (73%) significantly stenosed coronary arteries (greater than or equal to 70% reduction in endoluminal diameter), and Tc-99m-teboroxime detected 160 abnormal segments corresponding to 29 of 45 (64%) stenosed arteries. Thallium-201 and Tc-99m-teboroxime studies were normal in 3 patients. In conclusion, this study shows that there is a good correlation in the imaging results found with thallium-201 and Tc-99m-teboroxime using dipyridamole infusion on both a segmental and a diagnostic comparison. 相似文献
10.
To determine the clinical significance of an increased thallium-201 (Tl-201) activity in the lung and of its clearance from the lung after exercise, computer-quantitated Tl-201 lung activity was measured and compared with hemodynamic parameters at rest and during exercise in 35 patients with coronary artery disease (CAD). All patients underwent a supine bicycle ergometer exercise test and mean pulmonary artery wedge pressure (PAWP) was measured by a Swan-Ganz catheter. Coronary angiography was also performed. On computer-generated initial and 2 and a half hours delayed anterior images, regions of interest were selected over the myocardium (M) and lung (L), and the initial L/M ratio and the (initial L)/(delayed L) ratio were calculated as indices of an increased Tl-201 lung uptake and lung clearance, respectively. The initial L/M ratio and the (initial L)/(delayed L) ratio had no significant correlation with mean PAWP at rest and had a weak negative correlation with the resting ejection fraction (r = -0.57 and r = -0.58, respectively). However, both ratios showed good correlations with mean PAWP during peak exercise (r = 0.85 and r = 0.80, respectively), suggesting that they provide useful indices for assessing the severity of exercise-induced left ventricular dysfunction. 相似文献
11.
First pass radionuclide angiocardiography and thallium-201 myocardial perfusion imaging were performed at rest and during exercise in 48 patients with chest pain: 39 with angiographically documented coronary artery disease and 9 with normal coronary arteries. Maximal graded upright bicycle exercise was used for both studies to assure identical exercise conditions. All nine patients without coronary artery disease had normal exercise thallium images, normal exercise regional wall motion and at least a 5 percent absolute increase in left ventricular ejection fraction during exercise (normal exercise left ventricular reserve). Ischemic S-T segment depression was demonstrated in 17 (44 percent) of the 39 patients with coronary artery disease. Findings on the two exercise tests were concordant in all cases. New or augmented thallium perfusion defects were detected in 24 (62 percent) of the 39 patients, whereas abnormal exercise left ventricular reserve was present in 33 (85 percent) (p <0.05). There was a close concordance between exercise-induced perfusion defects and regional wall motion abnormalities. The magnitude of change in ejection fraction from rest to exercise was significantly greater in patients with an abnormal exercise thallium study than in those with a normal study (−8 ± 2 percent versus −1 ± 1 percent, p <0.05). Both radionuclide studies were abnormal In 21 (54 percent) of the 39 patients, whereas both were normal only in 3 patients, all of whom had single vessel disease. Abnormal exercise left ventricular reserve was present in 12 patients with normal exercise thallium studies. 相似文献
12.
The incremental prognostic value of combined regional wall motion and perfusion over perfusion alone by gated single-photon emission computed tomographic myocardial perfusion scintigraphy has not been evaluated. Of the 402 consecutive patients who underwent stress single-photon emission computed tomographic myocardial perfusion scintigraphy for suspected myocardial ischemia, we identified 333 patients (217 men, mean age 63 +/- 10 years; exercise in 249 and dipyridamole adminstered to 84). Visual scoring of perfusion images and regional wall motion used 20 segments and a scale of 0 to 4. Resting and poststress left ventricular ejection fraction was automatically generated. On follow-up (median 13 months), 30 hard cardiac events (17 cardiac deaths, 13 nonfatal acute myocardial infarctions) and 66 total cardiac events (including hard events, 26 with unstable angina, and 10 who underwent late revascularization) occurred. After adjustment for prescan information, the best independent predictors of hard events were summed stress score for wall motion (Wald's chi-square 8.3, p <0.004) and several vascular territories with ischemia by perfusion/function (Wald's chi-square 6.2, p <0.01). The strongest predictors of all cardiac events were the number of ischemias (Wald's chi-square 32.1, p <0.0001) and the number of ischemic vascular territories by perfusion (Wald's chi-square 13.1, p <0.0001). Addition of function data to the combined model of perfusion data yielded an incremental value of 26% for predicting hard events but not for all events. In conclusion, the assessment of combined perfusion/function provides incremental prognostic information for further hard events with perfusion data alone; perfusion data best predict all cardiac events. 相似文献
13.
Forty-two patients with known stable coronary artery disease, referred for coronary angiography, were examined with technetium-99m-hexakis-2-methoxy-2-methylpropyl-isonitrile (MIBI) tomography combined with a high-dose dipyridamole infusion (0.7 mg/kg) and handgrip stress. MIBI tomography was unable to show coronary artery disease only in 2 patients, thus yielding a sensitivity figure of 95%. MIBI tomography correctly identified 27 (82%) of 33 stenotic lesions (greater than or equal to 50% diameter stenosis) of the left anterior descending artery, 17 (61%) of 28 of those of the left circumflex artery, and 28 (90%) of 31 of those of the right coronary artery. The overall vessel sensitivity was 78%. The computed lumen diameter stenoses were more advanced in cases detected than in those not detected with MIBI tomography: 87 +/- 14 vs 76 +/- 14% (p less than 0.01). The 50 to 69% stenoses did not show any tendency to produce less positive findings than those with greater than or equal to 70% stenoses. In the subgroup of 21 patients who also presented for thallium scintigraphy, the overall diseased vessel identification rate was 76% for thallium tomography and 83% for MIBI tomography (p = not significant). Minor noncardiac side effects related to the dipyridamole-handgrip test occurred only in 5% of 63 study sessions. A high-dose dipyridamole combined with isometric exercise is a safe stress method, and when used during scintigraphy, MIBI tomography is at least as efficient a tool as thallium tomography in detecting diseased vessel territories in patients in coronary artery disease. 相似文献
14.
OBJECTIVES. The purpose of the present study was to compare single-photon emission computed tomographic (SPECT) myocardial images of technetium-99m (Tc-99m) sestamibi and thallium-201 (Tl-201) isotopes in the same dog undergoing partial coronary occlusion during pharmacologic vasodilation. BACKGROUND. To date, no controlled study has been reported comparing SPECT Tc-99m sestamibi with SPECT Tl-201 imaging during stress with anatomic and physiologic standards. METHODS. Mongrel dogs were anesthetized with chloralose and instrumented to record left anterior descending coronary blood flow and aortic pressure. Partial coronary occlusion with a hydraulic cuff reduced coronary vascular conductance, which is equal to the coronary blood flow normalized to aortic pressure during peak vasodilation with intravenous adenosine. Each dog received 5 mCi of Tl-201, then 30 mCi of Tc-99m sestamibi during partial coronary occlusion at peak vasodilation. Tomographic myocardial imaging was performed in a 180 degrees anterior arc scan for 33.5 min, first with Tl-201, and later, without moving the dog, for 33.5 min with Tc-99m sestamibi. Postmortem staining defined the region underperfused because of its dependence on the artery that was partially occluded. RESULTS. In seven dogs with moderate reduction in coronary blood flow, coronary vascular conductance decreased with partial coronary occlusion (47 +/- 12%) during Tl-201 imaging and (47 +/- 8%, p = NS) during Tc-99m sestamibi imaging. The underperfused region was 23.9 +/- 6.4% of total left ventricular mass. Counts in the defects were 39% higher (0.86 +/- 0.08 of normal counts) for Tc-99m sestamibi than for Tl-201 (0.64 +/- 0.09 of normal counts, p < 0.001), and the defect on SPECT Tc-99m sestamibi images occupied only a fraction (0.37 +/- 0.30) of the area of the defect on the Tl-201 images of the same dog. Bull's-eye displays constructed from the pathologic slices showed that the Tl-201 defect size was closer to the underperfused region of the left ventricular mass determined pathologically than was the Tc-99m sestamibi defect size. In four additional dogs a severe, near total coronary occlusion was created during Tl-201 and Tc-99m sestamibi administration. In these dogs, similar defect contrast (0.55 +/- 0.12 vs. 0.62 +/- 0.09, p = NS) and areas (0.18 +/- 0.07 vs. 0.18 +/- 0.11, p = NS) were observed with Tl-201 and Tc-99m sestamibi, respectively. CONCLUSIONS. Tomographic myocardial imaging with Tc-99m sestamibi during moderately severe partial coronary occlusion underestimated the area of the defect relative to Tl-201 or to the pathologic reference standard in dogs. Defect contrast was sharper with tomographic myocardial Tl-201 than with tomographic myocardial Tc-99m sestamibi during moderately severe partial coronary occlusion. 相似文献
15.
The state of left ventricular function and myocardial perfusionare important determinants of prognosis in patients with coronaryartery disease and information on both can be valuable for planningindividual patient management. We have studied the feasibilityof simultaneous measurement of left ventricular ejection fractionwith ultra short-lived gold-195 m (half life 30.5 seconds) andmyocardial perfusion with thallium-201, at rest and after exercisewith a single-crystal gamma camera. The results with first-passradionuclide angiocardiography (RNA) using gold-195 m at restwere reproducible and agreed closely with the results obtainedusing technetium-99 m equilibrium radionuclide angiocardiography(r = 0.93). Ejection fraction by firstpass gold-195 m RNA duringsemi-supine ergometric exercise decreased by >5% in 13 outof 18patients with coronary artery disease and stable angina.Simultaneous myocardial imaging with thallium-201 was abnormalin all patients. The change in regional wall motion abnormalityscore during exercise correlated with the change in myocardialperfusion (r = 0.71, P<0.01) and with the change in globalleft ventricular ejection fraction (r = 0.77, P<0.001). Thewidely differing energy levels and half-lives of gold-195 mand thallium-201 made it possible to separate clearly the imagesdue to each radionuclide. This study has demonstrated the feasibilityof simultaneous or sequential assessment of left ventricularfunction and myocardial perfusion during a single exercise test,a technique which can offer advantages in clinical evaluationof patients with coronary artery disease. 相似文献
16.
The favorable physical characteristics of technetium-99m-labeled 2-methoxy-2-methylisopropyl-1-isonitril (Tc-SESTAMIBI) enable the combined evaluation of both myocardial perfusion and left ventricular wall motion. To assess the potential of rest and exercise regional myocardial function as an adjunct to planar myocardial perfusion imaging, 60 patients with coronary artery disease and documented arteriographic findings were studied with both protocols during a single study. Exact segmental concordance between myocardial perfusion and wall motion studies was 77% (701/900 segments). Overall sensitivity and specificity to detect hemodynamically significant coronary artery disease with Tc-SESTAMIBI myocardial perfusion imaging were 89% and 79%, respectively, with resting wall motion studies 83% and 71%, respectively, and with rest/exercise wall motion studies, 85% and 71%, respectively. If the results of both perfusion and rest/exercise studies were combined, sensitivity increased to 96% and specificity decreased to 64%. The differences with perfusion studies alone were not statistically significant. Thus despite a good correlation between regional left ventricular function and perfusion, no statistically significant incremental diagnostic value was found when the results of both perfusion and wall motion studies were combined. 相似文献
17.
This report reviews the applications of tomographic imaging with current and new tracers in assessing myocardial perfusion and viability. Multiple studies with thallium-201 (TI-201) single photon emission computed tomography (SPECT) imaging for the detection of coronary artery disease (CAD) have demonstrated high sensitivity, high rates of normalcy and high reproducibility. In assessing viability, fixed defects are frequently detected in viable zones in 4-hour studies with TI-201 imaging. Redistribution imaging performed 18 to 72 hours after injection or reinjection of TI-201 before 4-hour redistribution imaging has been shown to improve accuracy of viability assessment. TI-201 SPECT studies are limited by the suboptimal physical properties of TI-201, which result in variable image quality. The 2 new technetium-99m (Tc-99m) - labeled myocardial perfusion tracers offer the ability to inject much higher amounts of radioactivity, making it possible to assess ventricular function as well as myocardial perfusion from the same injection of radiotracer. Tc-99m sestamibi has very slow myocardial clearance, which allows for prolonged imaging time and results in image quality superior to that obtained with TI-201 and Tc-99m teboroxime. The combination of minimal redistribution of Tc-99m sestamibi and high count rates makes gated SPECT imaging feasible, and also permits assessment of patients with acute ischemic syndromes by uncoupling the time of injection from the time of imaging. The combination of high image quality and first-pass exercise capabilities may lead to a choice of this agent over TI-201 for assessment of chronic CAD.(ABSTRACT TRUNCATED AT 250 WORDS) 相似文献
18.
Forty-seven consecutive patients (mean age 61 +/- 8 years) referred for cardiac catheterization due to moderate to severe aortic (n = 30) or mitral (n = 17) valvular heart disease were examined by technetium-99m isonitrile tomography together with a high-dose dipyridamole infusion (0.7 mg/kg) and handgrip stress. Tomography did not identify coronary artery disease (CAD) in 3 of the 21 patients with angiographically proven disease (sensitivity 86%) and suggested false positive results in 5 of the 26 without the disease (specificity 81% and negative predictive accuracy 88%). No patient without angina pectoris and with negative scintigraphy (n = 14) had angiographically significant (greater than or equal to 50% diameter stenosis) CAD. Overall vessel sensitivity was 63%, and specificity was 92%. The frequency of side effects during the dipyridamole-handgrip test was only 7%. No serious complications occurred during stress tests. Thus, technetium-99m isonitrile tomographic imaging, together with high-dose dipyridamole and handgrip exercise, is a useful noninvasive method in excluding significant CAD in patients with valvular heart disease. 相似文献
19.
Rest and exercise radionuclide angiocardiographic measurements of left ventricular function were obtained in 496 patients who underwent cardiac catheterization for chest pain. Two hundred forty-eight of these patients also had an exercise treadmill test. An ejection fraction less than 50% was the abnormality of resting left ventricular function that provided the greatest diagnostic information. In patients with normal resting left ventricular function, exercise abnormalities that were optimal for diagnosis of coronary artery disease were an injection fraction at least 6% less than predicted, an increase greater than 20 ml in end-systolic volume and the appearance of an exercise-induced wall motion abnormality. The sensitivity and specificity of the test were lower in patients who were taking propranolol at the time of study and in patients who failed to achieve an adequate exercise end point. In the 387 patients with an optimal study, the test had a sensitivity of 90% and a specificity of 58%. Radionuclide angiocardiography was more sensitive and less specific than the exercise treadmill test. The high degree of sensitivity of the radionuclide test suggests that it is most appropriately applied to patient groups with a high prevalence of disease, including those considered for cardiac catheterization. 相似文献
20.
Single-photon emission computed tomography (SPECT) using thallium-201 (Tl-201) was compared with technetium-99m hexakis 2-methoxyisobutyl isonitrile (Tc-99m MIBI) in 24 patients with coronary artery diseaes. Patients exercised to the same work load as each isotope was studied. Normal and hypoperfused left ventricular mass was determined with an automated method. Estimated total left ventricular mass was similar for both stress/redistribution Tl-201 and stress/rest Tc-99m MIBI images. The mean estimated defect size in the redistribution Tl-201 images was 32 +/- 34.7 vs 33 +/- 38.4 g in the resting Tc-99m MIBI studies (difference not significant). The individual determinations of defect mass were highly correlated (r = 0.93; p less than 0.0001). Estimated defect size in the stress Tl-201 images (52 +/- 46.2 g) was significantly larger than the exercise Tc-99m MIBI estimates of defect mass (42 +/- 39.9 g; p less than 0.05). A linear correlation existed between stress thallium and technetium estimates of defect size (r = 0.85) but 15 of 24 Tc-99m MIBI defects were smaller than the Tl-201 defects. Partial redistribution of Tc-99m MIBI could explain the discordance. Stress Tc-99m MIBI SPECT defect size determined by visual interpretation or by the use of isocount analysis may be smaller than what is seen with stress Tl-201 SPECT. 相似文献
|