首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Objectives:

To evaluate intra-rater and inter-rater reliability and measurement error in glenohumeral range of motion (ROM) measurements using a standard goniometer.

Study design:

17 adult subjects with and without shoulder pathology were evaluated for active and passive range of motion. Fifteen shoulder motions were assessed by two raters to determine reliability. The intra-class correlation coefficients (ICC) were calculated and examined to determine if reliability of ICC ≥ 0.70 existed. The standard error of measurement (SEM) and the minimal clinical difference (MCD) were also calculated.

Results:

Thxe criterion reliability was achieved in both groups for intra-rater reliability of standing AROM abduction; supine AROM and PROM abduction, flexion, external rotation at 0° abduction; and for inter-rater reliability of supine AROM and PROM abduction, external rotation at 0° abduction. The SEM ranged from 4°-7° for intra-rater and 6°-9° for inter-rater agreement on movements that achieved the criterion reliability. The MCD ranged from 11°-16° for a single evaluator and 14°-24° for two evaluators.

Conclusions:

Assessment of AROM and PROM in supine achieves superior reliability. The use of either a single or multiple raters affects the number of movements that achieved clinically meaningful reliability. Some movements consistently did not achieve the criterion and may not be the best movements to monitor treatment outcome.  相似文献   

2.

Purpose/Background:

A variety of methods exist to measure ankle dorsiflexion range of motion (ROM). Few studies have examined the reliability of a novice rater. The purpose of this study was to determine the reliability of ankle ROM measurements using three different techniques in a novice rater.

Methods:

Twenty healthy subjects (mean±SD, age=24±3 years, height=173.2±8.1 cm, mass=72.6±15.2 kg) participated in this study. Ankle dorsiflexion ROM measures were obtained in a weight-bearing lunge position using a standard goniometer, digital inclinometer, and a tape measure using the distance-to-wall technique. All measures were obtained three times per side, with 10 minutes of rest between the first and second set of measures. Intrarater reliability was determined using an intraclass correlation coefficient (ICC2,3) and associated 95% confidence intervals (CI). Standard error of measurement (SEM) and the minimal detectable change (MDC) for each measurement technique were also calculated.

Results:

The within-session intrarater reliability (ICC2,3) estimates for each measure are as follows: tape measure (right 0.98, left 0.99), digital inclinometer (right 0.96; left 0.97), and goniometer (right 0.85; left 0.96). The SEM for the tape measure method ranged from 0.4–0.6 cm and the MDC was between 1.1–1.5 cm. The SEM for the inclinometer was between 1.3–1.4° and the MDC was 3.7–3.8°. The SEM for the goniometer ranged from 1.8–2.8° with an MDC of 5.0–7.7°.

Conclusions:

The results indicate that reliable measures of weight-bearing ankle dorsiflexion ROM can be obtained from a novice rater. All three techniques had good reliability and low measurement error, with the distance-to-wall technique using a tape measure and inclinometer methods resulting in higher reliability coefficients (ICC2,3=0.96 to 0.99) and a lower SEM compared to the goniometer (ICC2,3=0.85 to 0.96).

Level of Evidence:

2b  相似文献   

3.

Study Design:

Quasi-experimental, repeated measures.

Purpose/Background:

Functional performance tests that identify hip joint impairments and assess the effect of intervention have not been adequately described for dancers. The purpose of this study was to examine the reliability and validity of hop and balance tests among a group of dancers with musculoskeletal pain in the hip region.

Methods:

Nineteen female dancers (age: 18.90±1.11 years; height: 164.85±6.95 cm; weight: 60.37±8.29 kg) with unilateral hip pain were assessed utilizing the cross-over reach, medial triple hop, lateral triple hop, and cross-over hop tests on two occasions, 2 days apart. Test-retest reliability and comparisons between the involved and uninvolved side for each respective test were determined.

Results:

Intra-class correlation coefficients for the functional performance tests ranged from 0.89-0.96. The cross-over reach test had a SEM of 2.79 cm and a MDC of 7.73 cm. The medial and lateral triple hop tests had SEM values of 7.51 cm and 8.17 cm, and MDC values of 20.81 cm and 22.62 cm, respectively. The SEM was 0.15 seconds and the MDC was 0.42 seconds for the cross-over hop test. Performance on the medial triple hop test was significantly less on the involved side (370.21±38.26 cm) compared to the uninvolved side (388.05±41.49 cm); t(18) = −4.33, p<0.01. The side-to-side comparisons of the cross-over reach test (involved mean=61.68±10.9 cm; uninvolved mean=61.69±8.63 cm); t(18) = −0.004, p=0.99, lateral triple hop test (involved mean=306.92±35.79 cm; uninvolved mean=310.68±24.49 cm); t(18) = −0.55, p=0.59, and cross-over hop test (involved mean=2.49±0.34 seconds; uninvolved mean= 2.61±0.42 seconds; t(18) = −1.84, p=0.08) were not statistically different between sides.

Conclusion:

The functional performance tests used in this study can be reliably performed on dancers with unilateral hip pain. The medial triple hop test was the only functional performance test with evidence of validity in side-to-side comparisons. These results suggest that the medial triple hop test may be a reliable and valid functional performance test to assess impairments related to hip pain among dancers.

Level of Evidence:

3b. Non-consecutive cohort study  相似文献   

4.

BACKGROUND:

Acupuncture stimulates points on the body, influencing the perception of myofascial pain or altering physiologic functions.

OBJECTIVE:

The aim was to evaluate the effect of electroacupuncture (EAC) and acupuncture (AC) for myofascial pain of the upper trapezius and cervical range of motion, using SHAM acupuncture as control.

METHOD:

Sixty women presenting at least one trigger point at the upper trapezius and local or referred pain for more than six months were randomized into EAC, AC, and SHAM groups. Eight sessions were scheduled and a follow-up was conducted after 28 days. The Visual Analog Scale assessed the intensity of local and general pain. A fleximeter assessed cervical movements. Data were analyzed using paired t or Wilcoxon''s tests, ANOVA or Friedman or Kruskal-Wallis tests and Pearson''s correlation (α=0.05).

RESULTS:

There was reduction in general pain in the EAC and AC groups after eight sessions (P<0.001). A significant decrease in pain intensity occurred for the right trapezius in all groups and for the left trapezius in the EAC and AC groups. Intergroup comparisons showed improvement in general pain in the EAC and AC groups and in local pain intensity in the EAC group (P<0.05), which showed an increase in left rotation (P=0.049). The AC group showed increases in inclination (P=0.005) sustained until follow-up and rotation to the right (P=0.032).

CONCLUSION

: EAC and AC were effective in reducing the pain intensity compared with SHAM. EAC was better than AC for local pain relief. These treatments can assist in increasing cervical range of motion, albeit subtly.  相似文献   

5.

Background

Alterations in glenohumeral (GH) rotation especially internal rotation and total range of motion have been associated with altered GH kinematics and susceptibility to injury. Researchers have evaluated long-term change in baseball and tennis players, and short-term changes in baseball players. However, acute (short-term) changes in GH rotation have not been evaluated in tennis players.

Hypotheses/Purpose

The purpose of this study was to quantify short-term glenohumeral rotational changes within a group of professional women''s tennis players following competitive play. It was hypothesized that there would be acute alterations in passive glenohumeral internal rotation and total range of motion following episodes of tennis play.

Study Design

Cohort Study

Methods

Passive glenohumeral external rotation (GER), glenohumeral internal rotation (GIR), and total range of motion (TROM) were evaluated in a cohort of 79 professional adult female tennis players. Measurements were taken at three different time points (TP): baseline before match play (TP1), immediately after match play (TP2), and 24-hours after baseline (TP3).

Results

There was a statistically significant decrease in the mean GIR from TP1 (43 ± 11 °) to TP2 (39 ± 9 °) (p=0.002) and from TP1 to TP3 (38 ± 10 °) (p=0.001). All measures were at the level of minimal detectable change (MDC) (4 °) indicating clinical significance. There was a decrease in mean TROM from TP1 (146 ± 11 °) to TP2 (142 ± 12 °) (p=0.04), which was not above MDC (7 °). Subgroup analysis showed that 47% of the players demonstrated a decrease in GIR beyond MDC, and 37% demonstrated a decrease in TROM beyond MDC. GER remained unchanged across all time points (p>0.05).

Conclusion

Both GIR and TROM were reduced after acute exposure to tennis play. In a large subgroup of the cohort, the changes were clinically significant and approached values previously demonstrated to be associated with increased injury risk. Given the changes in glenohumeral motion following acute exposure to tennis, evaluation of players for significant motion alterations following overhead activity and intervention strategies to minimize such alterations in these players are recommended for high level tennis players.

Level of evidence

Level 3  相似文献   

6.

BACKGROUND:

Handgrip strength is currently considered a predictor of overall muscle strength and functional capacity. Therefore, it is important to find reliable and affordable instruments for this analysis, such as the modified sphygmomanometer test (MST).

OBJECTIVES:

To assess the concurrent criterion validity of the MST, to compare the MST with the Jamar dynamometer, and to analyze the reproducibility (i.e. reliability and agreement) of the MST in individuals with Parkinson''s disease (PD).

METHOD:

The authors recruited 50 subjects, 24 with PD (65.5±6.2 years of age) and 26 healthy elderly subjects (63.4±7.2 years of age). The handgrip strength was measured using the Jamar dynamometer and modified sphygmomanometer. The concurrent criterion validity was analyzed using Pearson''s correlation coefficient and a simple linear regression test. The reproducibility of the MST was evaluated with the coefficient of intra-class correlation (ICC2,1), the standard error of measurement (SEM), the minimal detectable change (MDC), and the Bland-Altman plot. For all of the analyses, α≤0.05 was considered a risk.

RESULTS:

There was a significant correlation of moderate magnitude (r≥0.45) between the MST and the Jamar dynamometer. The MST had excellent reliability (ICC2,1≥0.7). The SEM and the MDC were adequate; however, the Bland-Altman plot indicated an unsatisfactory interrater agreement.

CONCLUSIONS:

The MST exhibited adequate validity and excellent reliability and is, therefore, suitable for monitoring the handgrip strength in PD. However, if the goal is to compare the measurements between examiners, the authors recommend that the data be interpreted with caution.  相似文献   

7.
8.

Objectives:

Neck pain can be evaluated with passive intervertebral motion (PIVM). No study has evaluated the reliability of three-dimensional (3D) segmental PIVM testing of the cervical spine in symptomatic subjects in a functional, seated position. The purpose of this study was to evaluate inter-rater reliability of such 3D PIVM technique for pain provocation, hypomobility, and end-feel detection.

Methods:

Subjects (n = 63), age 44±15·6 years, neck pain 3·4±1·6 cm with visual analog scale, were evaluated by two of three raters with varied manual therapy education and experience. To perform the test, the rater passively invoked side-bending motion at each cervical joint from C2–C3 to C6–C7, allowing segmental synkinetic rotation and extension to occur. Each joint was assessed for hypomobility, hard end-feel, and pain provocation. Kappa statistics were used to determine the inter-rater reliability for each variable for joints C2–C3 through C6–C7 for both the most painful and least painful sides.

Results:

Percent agreements for pain provocation, hypomobility, and end-feel ranged 65–83%, 62–84%, and 68–87%, respectively. Kappa values for pain provocation, hypomobility, and end-feel on the most painful side were fair to moderate (0·29–0·53, 0·21–0·48, and 0·25–0·50, respectively), and on the least painful side were fair to substantial (0·43–0·65, 0·33–0·58, and 0·28–0·60, respectively).

Discussion:

This is the first investigation to assess reliability of 3D cervical segmental testing in sitting and to assess reliability of end-feel. The seated 3D PIVM test has sufficient clinical reliability for use in patients with cervicalgia for the assessment of hypomobility, end-feel, and pain provocation.  相似文献   

9.

Purpose/Background:

The decision to return an athlete to sports following anterior cruciate ligament reconstruction can be controversial. The purposes of this study are 1) to describe a functional test (Vail Sport Test™) that includes the evaluation of muscle strength, endurance, power, and movement quality in those patients attempting to return to sports following ACL reconstruction and 2) to assess the reliability of the Vail Sport Test™.

Methods:

A prospective cohort study design. A total of 30 (12 F, 18 M) subjects (18.1±5.3 yrs) volunteered for the study. All subjects were post-operative ACL reconstruction (5.2±1.9 months) and were in the process of returning to sports. Each subject completed the Vail Sport Test™ and was videotaped from the anterior and lateral view. The videotape was then viewed and graded at two different points in time (48 hours apart) by three licensed physical therapists. Intraclass correlations (ICCs) were calculated to determine intra- and inter-rater reliability.

Results:

Intra-rater reliability was excellent with a range of .95 to 1.0. Reliability values between graders were .97 (ICC2,k) and 1.55 (SEM).

Conclusions:

The results of this study suggest that the Vail Sport Test™ has excellent reliability when the same graders scored the test using video on repeated occasions. In addition, the test was reliable between different graders.

Level of Evidence:

Level 2b  相似文献   

10.

Background

An inadequate level of flexibility of the adductor muscles is one of the most critical risk factors for chronic groin pain and strains. However, measurement methods of adductor muscle flexibility are not well defined.

Purpose

To determine the inter‐session reliability of the biarticular and monoarticular adductor muscle flexibility measures obtained from passive hip abduction with the knee flexed over the edge of the plinth test (PHA) and the passive hip abduction test at 90° of hip flexion (PHA90°).

Study design

Clinical Measurement Reliability study.

Methods

Fifty healthy recreational athletes participated in this study. All participants performed the PHA and PHA90° on four different occasions, with a two‐week interval between testing sessions. Reliability was examined through the change in the mean between consecutive pairs of testing sessions (ChM), standard error of measurement expressed in absolute values (SEM) and as a percentage of the mean score (%SEM), minimal detectable change at 95% confidence interval (MDC95), and intraclass correlation coefficients (ICC2,k).

Results

The findings showed negligible or trivial ChM values for the two adductor flexibility measures analyzed (<2°). Furthermore, the SEM and MDC95 were 2.1° and 5.9° and 2.2° and 6.2° for the measures obtained from the PHA and PHA90°, respectively, with %SEM scores lower than 5% and ICC scores higher than 0.90.

Conclusion

The findings from this study suggest that the adductor muscle flexibility measures analyzed have good to excellent inter‐session reliability in recreational athletes. Thus, clinicians can be 95% confident that an observed change between two measures larger than 5.9° and 6.2° for the flexibility measures obtained from the PHA and PHA90°, respectively, would indicate a real change in muscle flexibility.

Level of evidence

2  相似文献   

11.

Purpose/Aim:

This study investigated the intrarater reliability and concurrent validity of active shoulder mobility measurements using a digital inclinometer and goniometer.

Materials/Methods:

Two investigators used a goniometer and digital inclinometer to measure shoulder flexion, abduction, internal and external rotation on 30 asymptomatic participants in a blinded repeated measures design.

Results:

Excellent intrarater reliability was present with Intraclass Correlation Coefficients (ICC- 3,k) for goniometry ≥ 0.94 and digital inclinometry ≥ 0.95. The concurrent validity between goniometry and digital inclinometry was good with ICC (3,k) values of ≥ 0.85. The 95% limits of agreement suggest that the difference between these two measurement instruments can be expected to range from 2° to 20°.

Conclusions:

The results cautiously support the interchangeable use of goniometry and digital inclinometer for measuring shoulder mobility measurements. Although reliable, clinicians should consider the 95% limits of agreement when using these instruments interchangeably as clinically significant differences are likely to be present.

Level of evidence:

2b  相似文献   

12.

Background/Purpose:

The Myotonometer® is an electronic tissue compliance meter that has been used to quantify the compliance of soft tissues. The Myotonometer® may be a valuable tool to measure the effectiveness of interventions commonly used to increase tissue compliance in individuals with posterior shoulder tightness (PST). Limited data exist on reliability and responsiveness of the Myotonometer® for assessment of soft tissues about the shoulder; therefore, the purpose of this study is to determine the intra‐ and inter‐session reliability and responsiveness of the Myotonometer® in measuring tissue compliance of the posterior shoulder musculature in asymptomatic subjects with PST.

Methods:

Fifteen asymptomatic subjects with unilateral shoulder range of motion deficits attended two measurement sessions to assess the compliance of the tissues overlying the posterior deltoid, infraspinatus, and teres musculature. Analyses of reliability and responsiveness were conducted using intra‐class correlation coefficients (ICCs) and the determination of minimal detectible change (MDC).

Results:

Intra‐session ICC values ranged from 0.69 to 0.91 for all muscles with MDC never exceeding 1.0 mm. Inter‐session ICC values were best for the posterior deltoid, which averaged 0.82, compared to the infraspinatus and the teres complex, which averaged 0.42 and 0.5 respectively. Inter‐session MDC ranged from 0.55 to 1.20 mm across all muscles.

Conclusions:

Clinicians can reliably detect relatively small changes in tissue compliance within a single treatment session utilizing the Myotonometer®. The Myotonometer® can reliably detect changes between sessions for tissues overlying the posterior deltoid; however, observed change in the infraspinatus and teres musculature must be above 1 mm to achieve meaningful change and account for decreased inter‐session reliability.

Level of Evidence:

3  相似文献   

13.

Objectives:

Myofascial trigger points (MTrPs) are considered the principal clinical feature of myofascial pain syndrome (MPS). An MTrP consists of spot tenderness within a taut band of muscle fibers and its stimulation can produce both local and referred pain. The clinical diagnosis of MPS depends on correct history taking and a physical examination aimed at identifying the presence of MTrP. The purpose of this study was to investigate the intra-rater reliability of a palpation protocol used for locating an MTrP in the upper trapezius muscle.

Methods:

Twenty-four subjects with MTrP in the upper trapezius muscle were examined by an experienced physiotherapist. During each of eight experimental sessions, subjects were examined twice in randomized order using a palpation protocol. An anatomical landmark system was defined and the MTrP location established using X and Y values.

Results:

The intraclass correlation coefficient ICC(1,1) values were 0.62 (95% CI: 0.30–0.81) for X and 0.81 (95% CI: 0.61–0.91) for Y. The Bland–Altman plots for X and Y showed a mean of difference of 0.04 and −0.2 mm, respectively. Limits of agreement for X ranged from −26.3 to 26.2 mm and for Y from −27 to 26.4 mm.

Discussion:

The ICC(1,1) for the observed values revealed a moderate to high correlation and the Bland–Altman analysis showed means of difference very close to zero with narrow limits of agreement. An experienced physiotherapist can reliably identify MTrP locations in upper trapezius muscle using a palpation protocol.  相似文献   

14.

Background

Substantial deficits in performance of hip abductor in patients with common lower extremity injuries are reported in literature. Therefore, assessing hip abductor endurance might be of major importance for clinicians and researchers.

Purposes

The purpose of this study was to examine the test-retest reliability of two hip abductor endurance tests in healthy females. Learning effect, systematic difference in the rate of perceived exertion and relationship between endurance performance and some clinical characteristics of participants were also investigated.

Design

Observational study, with a test-retest design.

Methods

Thirty-six healthy females, aged 18-30 years, were recruited. In two identical assessment sessions, the participants performed an isometric hip abductor strength test and two different hip abductor endurance tests

Results

Isometric and dynamic endurance tests demonstrated good test-retest reliability (intraclass correlation coefficients (ICC) = 0.73 and 0.78, respectively). The standard errors of measurement (SEM) and the minimal detectable changes (MDC) were, respectively, 19.8 and 54.9 seconds for isometric endurance test and 21.2 and 58.7 repetitions for dynamic endurance test. Moderate correlation between both endurance tests (r = 0.60, p = 0.0001) and weak correlation between dynamic endurance test and strength (r = 0.44, p = 0.008) were found.

Conclusions

The results of the present study demonstrate good test-retest reliability of two non-instrumented clinical tests of hip abductor endurance in healthy females.

Level of evidence

2b  相似文献   

15.

BACKGROUND:

The Balance Evaluation Systems Test (BESTest) was recently created to allow the development of treatments according to the specific balance system affected in each patient. The Brazilian version of the BESTest has not been specifically tested after stroke.

OBJECTIVE:

To evaluate the intra- and inter-rater reliability and concurrent and convergent validity of the total score of the BESTest and BESTest sections for adults with hemiparesis after stroke.

METHOD:

The study included 16 subjects (61.1±7.5 years) with chronic hemiparesis (54.5±43.5 months after stroke). The BESTest was administered by two raters in the same week and one of the raters repeated the test after a one-week interval. Intraclass correlation coefficient (ICC) was calculated to assess intra- and interrater reliability. Concurrent validity with the Berg Balance Scale (BBS) and convergent validity with the Activities-specific Balance Confidence scale (ABC-Brazil) were assessed using Pearson''s correlation coefficient.

RESULTS:

Both the BESTest total score (ICC=0.98) and the BESTest sections (ICC between 0.85 and 0.96) have excellent intrarater reliability. Interrater reliability for the total score was excellent (ICC=0.93) and, for the sections, it ranged between 0.71 and 0.94. The correlation coefficient between the BESTest and the BBS and ABC-Brazil were 0.78 and 0.59, respectively.

CONCLUSIONS:

The Brazilian version of the BESTest demonstrated adequate reliability when measured by sections and could identify what balance system was affected in patients after stroke. Concurrent validity was excellent with the BBS total score and good to excellent with the sections. The total scores but not the sections present adequate convergent validity with the ABC-Brazil. However, other psychometric properties should be further investigated.  相似文献   

16.

Background/Purpose:

Movement ability is an often‐overlooked component of sports science and sports medicine research and needs to be considered alongside the appraisal of physical fitness and performance characteristics. To achieve this, a standardised assessment tool is required. The purpose of this paper is to introduce a new method for assessing movement ability and present results for intra‐ and inter‐rater reliability.

Methods:

National level female football players (n=17) were assessed using a novel movement assessment tool, the Athletic Ability Assessment (AAA). Athletes were assessed according to the scoring criteria by the primary researcher in real‐time and via video on two separate occasions to estimate intra‐tester reliability. Inter‐tester reliability was estimated using the difference between five other testers'' video‐based scores.

Results:

The intra‐tester minimal detectable change (MDC) for the composite AAA score was 2.9 points (90% confidence limits; 2.3 – 4.2 points) (2.5%; 2.0 – 3.6%) with an intraclass correlation coefficient (ICC) of 0.97 (0.92 – 0.99). Inter‐tester MDC for the composite AAA score was 2.8 points (2.5 – 3.3 points) (2.4%; 2.1 – 2.8%) with an ICC 0.96 (0.94 – 0.98) Individual exercise scores for the intra‐ and inter‐tester show a similar range MDC of between 0.4 – 1.1 points and kappa statistic level of agreement between 0.32 ‐0.77.

Conclusions:

Results of the reliability analysis suggest high levels of agreement between scorers for total scores and provide reference values for minimal detectable changes using the AAA. The aim of the AAA is to become a reliable movement assessment protocol that addresses specific sporting populations. The reliability of AAA scoring established in this study is the first step in supporting the utilization of the AAA in future research.

Level of evidence:

2b  相似文献   

17.

Background

Different limb training demands and limb preference may determine anthropometric and muscle force inter-limb asymmetries in Rhythmic Gymnastics (RG) athletes.

Purpose

The purpose of this study was to evaluate the influence of lateral preference of the lower extremity on anthropometric, range of motion, and isokinetic torque measurements of RG athletes.

Study Design

Cross sectional study

Methods

Lower limb anthropometric measurements (girth, estimated anatomical cross-sectional area), hip, knee and ankle range of motion, flexor and extensor isokinetic torques (angular velocities = 60, 180, e 240 °·s−1) and bilateral asymmetry index were evaluated in 11 international level Rhythmic Gymnastics athletes (17.9 ± 4.0 years of age; 9.1 ± 5,1 years of experience; 26.8 ± 6.0 weekly training hours).

Results

The preferred limb showed larger thigh girth and anatomical cross-sectional area, higher ankle dorsiflexor range of motion, higher hip flexor torque at 60 °·s−1 and higher plantarflexor torque at 180 °·s−1 compared to the non-preferred limb.

Conclusions

The observed differences seem to be strictly related to lateral preference and rhythmic gymnastics training.

Levels of Evidence

3  相似文献   

18.

Background

The significance of scapular dyskinesis is being challenged due to a lack of the association with pain and ability to predict injury in athletic populations. However, it is unknown whether asymptomatic overhead athletes with dyskinesis cope by normalizing scapular position with higher demand activities.

Hypothesis/Purpose

The purpose of this study was to compare change in scapular kinematics from an active unweighted contraction to a maximal isometric contraction in asymptomatic overhead athletes with and without scapular dyskinesis. Secondarily, force generated with manual muscle tests were explored for differences and relationships with kinematics.

Study Design

Cross‐sectional laboratory study

Methods

Twenty‐five matched asymptomatic overhead athletes with (n=14) and without (n=11) scapular dyskinesis, defined with a reliable and validated clinical method, participated in this study. Three‐dimensional scapular kinematics were evaluated in an active unweighted condition, and during maximal isometric contractions at 90 ° of shoulder flexion. Isometric force produced with lower trapezius and serratus anterior manual muscle tests were assessed with a dynamometer. Changes in scapular kinematics were compared between groups. Differences in force generated with manual muscle tests between groups and relationships with kinematics were explored.

Results

Athletes with dyskinesis demonstrated greater deficits in scapular upward rotation with maximal contraction (p=<0.001), less external rotation (p=0.036) and weaker lower trapezius manual muscle test strength (p=0.031). Lower trapezius (p=0.003;r=0.57) and serratus anterior (p=0.042;r=0.41) manual muscle test strength deficits were fair to moderately associated with a lack of scapular upward rotation during maximal contraction.

Conclusion

Small to moderate changes in scapular kinematics are normal responses to a maximal contraction, but with scapular dyskinesis this response is accentuated. Athletes with dyskinesis generate less force with lower trapezius manual muscle testing compared to athletes without dyskinesis. Decreased strength with lower trapezius and serratus anterior manual muscle testing was also related to a lack of upward rotation in all athletes.

Level of Evidence

3  相似文献   

19.

Objective

To refine the Physician Documentation Quality Instrument (PDQI) and test the validity and reliability of the 9-item version (PDQI-9).

Methods

Three sets each of admission notes, progress notes and discharge summaries were evaluated by two groups of physicians using the PDQI-9 and an overall general assessment: one gold standard group consisting of program or assistant program directors (n = 7), and the other of attending physicians or chief residents (n = 24). The main measures were criterion-related validity (correlation coefficients between Total PDQI-9 scores and 1-item General Impression scores for each note), discriminant validity (comparison of PDQI-9 scores on notes rated as best and worst using 1-item General Impression score), internal consistency reliability (Cronbach’s alpha), and inter-rater reliability (intraclass correlation coefficient (ICC)).

Results

The results were criterion-related validity (r = –0.678 to 0.856), discriminant validity (best versus worst note, t = 9.3, p = 0.003), internal consistency reliability (Cronbach’s alphas = 0.87–0.94), and inter-rater reliability (ICC = 0.83, CI = 0.72–0.91).

Conclusion

The results support the criterion-related and discriminant validity, internal consistency reliability, and inter-rater reliability of the PDQI-9 for rating the quality of electronic physician notes. Tools for assessing note redundancy are required to complement use of PDQI-9. Trials of the PDQI-9 at other institutions, of different size, using different EHRs, and incorporating additional physician specialties and notes of other healthcare providers are needed to confirm its generalizability.  相似文献   

20.

Background:

Hip range of motion is an important component in assessing clinical orthopedic conditions of the hip, low back and lower extremities. However it remains unclear as to what constitutes the best tool for clinical measurement. The purpose of this study was to investigate the concurrent validity of passive range of motion (ROM) measurements of hip extension and hip internal and external rotation using a digital inclinometer and goniometer.

Design:

Criterion Standard

Setting:

Clinical research laboratory

Participants:

30 healthy subjects without pain, radicular symptoms or history of surgery in the low back or hip regions.

Main Outcome Measures:

Passive hip range of motion for extension, hip internal rotation and hip external rotation. A digital inclinometer and universal goniometer were utilized as the tools for comparisons between measurements.

Results:

There was a statistically significant difference (p < 0.05) between the goniometer and digital inclinometer in measured hip ROM except for measurements of right hip external rotation (p > 0.05). The mean difference between the goniometer and digital inclinometer in left hip extension, internal rotation and external rotation were 3.5°, 4.5° and 5.0° respectively. The mean difference between the two devices in right hip extension, internal rotation and external rotation were 2.8°, 4.2° and 2.6° respectively. On average, the difference between the goniometer and digital inclinometer in extension was 3.2°, internal rotation was 4.5° and external rotation was 3.8°. The digital inclinometer had greater measurement during EXT and ER. Furthermore, there was no statistically significant difference (p > 0.05) in hip ROM between the left and right side for either goniometric or digital inclinometer measurements.

Conclusions:

This results of this study indicate that a significant difference exists between the two devices in all measurements with exception of right hip extension. The differences were noted to be between 3–5 degrees for all planes measured. These findings suggest that caution should be used if these two devices are to be used interchangeably to quantify passive hip range of motion in either clinical practice or when comparing studies that utilize different instruments.

Level of Evidence:

2b  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号