首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
STATEMENT OF PROBLEM: Cements that yield high retentive values are believed to allow use of shorter posts. PURPOSE: This study investigated the use of reinforced composite resin cement as compensation for reduced dowel length. MATERIAL AND METHODS: The retention values of stainless steel posts (parallel-sided ParaPost and tapered Dentatus in 5-, 8-, and 10-mm lengths) luted with Flexi-Flow titanium-reinforced composite resin and zinc phosphate cements were evaluated. Single-rooted extracted human teeth with crowns (n = 120), removed at the cementoenamel junction, were randomly divided into 4 groups of 30 samples each. Different post lengths were luted with either Flexi-Flow or zinc phosphate. Each sample was placed into a specialized jig and on a tensile testing machine with a crosshead speed of 2 mm/min, applied until failure. The effect of different posts and cements on the force required to dislodge the dowels was evaluated with multiple analyses of variance (ANOVA). One-way ANOVA with Scheffé contrast was applied to determine the effect of different post lengths on the retentive failure of posts luted with the 2 agents. RESULTS: Flexi-Flow reinforced composite resin cement significantly increased retention of ParaPost and Dentatus dowels (P<.001) compared with zinc phosphate. One-way ANOVA revealed no statistically significant difference (P>.05) between mean retention of both dowels luted with Flexi-Flow for all posts length used (5 mm = 8 mm = 10 mm). Mean retention values of the groups luted with zinc phosphate showed a statistically significant difference (P<.001) for the different post lengths (10 > 8 > 5 mm). Parallel-sided ParaPost dowels demonstrated a higher mean retention than tapered Dentatus dowels (P<.001). CONCLUSION: In this study, Flexi-Flow reinforced composite resin cement compensated for the reduced length of shorter parallel-sided ParaPost and tapered Dentatus dowels.  相似文献   

2.
PURPOSE: The first purpose of this study was to compare the retentive values of zinc phosphate and Panavia F resin cements when used for luting cast dowel and cores. The second purpose was to determine whether the use of a lubricant when making the resin pattern for a custom dowel and core would have an effect on the final retention of dowels cemented with either zinc phosphate or Panavia F cements. METHODS AND MATERIALS: Sixty-three caries-free extracted single-rooted human teeth were randomly divided into three groups of 21. Root canal preparations were standardized for all 63 teeth. Clinical protocols for fabricating and cementing dowel and core restorations were examined, comparing zinc phosphate and Panavia F resin cements. Direct dowel patterns were fabricated using the Para Post system and cast in a noble metal alloy. Group I dowel spaces were lubricated with GC lubricant prior to dowel pattern fabrication and cleaned with Cavidry solvent before cementing the cast dowel and core with zinc phosphate cement. Group II dowel spaces were rinsed with water only prior to dowel pattern fabrication. The dowels and cores in this group were cemented with Panavia F resin cement. Group III dowel spaces were lubricated with GC lubricant prior to dowel pattern fabrication; the dowel spaces were cleaned with Cavidry solvent before the cast dowel and cores were cemented with Panavia F cement. The tensile force necessary to remove the cast dowel and cores was determined using a universal testing machine. Results were statistically analyzed using one-way ANOVA and Tukey's HSD test. RESULTS: The dowels and cores in Group I had significantly higher retentive values than either of the two Panavia F groups (p< or = 0.001). No difference in retentive values (p > 0.05) was found between dowels luted with either of the lubricating agents in the Panavia F groups. CONCLUSIONS: Zinc phosphate cement had higher retentive values when cementing cast dowel and cores than Panavia F. The type of lubricant used for the resin dowel fabrication (water or GC lubricant that was removed with a solvent) had no effect on the retention of cast dowels cemented with Panavia F.  相似文献   

3.
A threaded, parallel-sided endodontic dowel that has a longitudinal split was tested to determine its retention and stress distribution properties. Photoelastic stress analysis revealed high installation stresses unless the dowels were counterrotated. Axial loading created stresses at the threads, with elevated coronal and apical stresses. Even higher coronal stresses were recorded with inclined loads, and shorter dowels generated greater stresses than longer dowels. The retentive values were generally lower than those in comparable studies.  相似文献   

4.
OBJECTIVE: To compare in vitro the retentive values of stainless steel, parallel-sided posts to quartz-fiber, tapered posts for 2 different dowel lengths (5 and 10 mm). METHOD AND MATERIALS: Both post systems were cemented with a dual-cure adhesive resin cement. Single-rooted extracted human teeth (n = 40) were decoronated and randomly divided into 4 groups of 10 samples each. Posts of 5 and 10 mm in length were luted with the resin cement. Each sample was placed on a universal testing machine, and using a push-out method, a vertical load was applied at a crosshead speed of 2 mm/min. The amount of force required to dislodge the post was recorded. The effect of post type and length was evaluated using a 2-way analysis of variance. RESULTS: A statistically significant main effect was found for post length (P <.001), with the 10-mm posts of both post systems requiring greater force to dislodge than the 5-mm posts. There was no interaction between post length and post type (P >.05). CONCLUSION: It is concluded from this study that there is no statistical difference in retention between quartz-fiber, tapered posts and stainless steel, parallel-sided posts when they are cemented with the same resin cement (P >.05). The study also concludes that adequate retentive values are achieved with both post systems at the shorter, 5-mm post length.  相似文献   

5.
Purpose: To explore the effect of fabrication technique, cement type, and cementation procedure on retention of cast metal dowels.
Methods and Materials: Eighty intact single-rooted teeth were selected. The clinical crown was removed at the cementoenamel junction level. Each root was prepared to receive a cast metal dowel of 10-mm length and 1.45 mm in diameter. The 80 specimens were divided into two major groups of 40 based on fabrication technique (direct and indirect). Each group was further divided into four subgroups of ten based on the cement type (zinc phosphate and glass ionomer), and cementation procedure (with and without lentulo spiral). The dowels were subjected to a constantly increasing tensile force, in a universal Instron testing machine, at crosshead speed of 5 mm/min until failure.
Results: The most significant factor to affect retention was the cementation procedure, as cementation with lentulo spiral produced greater retention than cementation without the use of lentulo spiral ( p < 0.05); however, there seems to be a close interaction between fabrication technique, cement type, and cementation procedure ( p = 0.051). The least retentive group was the one fabricated by direct technique, cemented with zinc phosphate without the use of lentulo spiral.
Conclusion: Fabrication technique does not affect retention of cast dowels, except when zinc phosphate was the luting agent and placed in the canal space without using a lentulo spiral. The cementation procedure had a significant effect on retention; thus, it is recommended that cementation should be done using the lentulo spiral.  相似文献   

6.
STATEMENT OF PROBLEM: Several new esthetic dowel systems are currently available for the restoration of endodontically treated teeth. These dowel systems enhance the esthetic quality of all-ceramic restorations better than metallic dowel systems. PURPOSE: The purpose of this study was to evaluate the retentive strength of composite and ceramic endodontic dowel systems to the tooth and to the core foundation. MATERIAL AND METHODS: The following dowel systems were tested: resin dowels (Fibrekor [FR]; Luscent [LU]; Twin Luscent Anchor [TLU]); ceramic dowels (Cerapost [CR]; Cosmopost [CO]); and a titanium dowel (ParaPost XH [Ti]). In Part I of the study, core retention was tested by forming Bis-Core resin (n=12) cores around dowels followed by separation using a universal testing machine. In Part II, 60 (n=12) extracted human canines were endodontically treated, and dowel spaces were prepared using the corresponding drill for each dowel system. Nine-millimeter resin and ceramic dowels were cemented with C & B resin luting agent. Additionally, 2 groups (n=12) of Ti dowels cemented with C & B resin luting agent and zinc phosphate luting agent served as control groups. Retention was tested using a universal testing machine to separate the dowels from teeth. One-way analysis of variance and Student Newman-Keuls tests were conducted for statistical analysis (alpha=.05). Surface texture of all dowel systems tested was examined using SEM at original magnification x25 and x250. RESULTS: Core retention of Ti was higher than all esthetic dowels tested (alpha<.05), but FR had higher core retention than the other esthetic dowels tested. Resin dowels had better retention to teeth than ceramic dowels (alpha<.05). CONCLUSION: The esthetic dowel systems were less retentive for the resin core material than the titanium control. Resin dowel systems were more retentive in the root than the ceramic dowels but were similar to the titanium control.  相似文献   

7.
A comparison of the retention of tooth-colored posts.   总被引:3,自引:0,他引:3  
OBJECTIVE: The aim of this in vitro study was to compare the retention of five different esthetic post systems of similar dimensions in extracted teeth using titanium posts as controls. METHOD AND MATERIALS: Sixty recently extracted single-rooted, caries-free teeth were sectioned horizontally and mounted in acrylic resin. The samples were randomly allocated into six groups of 10 for post preparation. Post space preparation was carried out according to the individual manufacturer's instructions. All posts were bonded using Panavia F. A 4-mm hollow, metal sleeve was luted over the free end of each post prior to mounting in a universal testing machine, and the forces required to dislodge the posts using a cross-head speed of 5 mm/min were recorded. RESULTS: It was found that the parallel-sided Lightposts were significantly more retentive than all of the other posts. Parapost Fibrewhite posts were more retentive than tapered Lightposts and Snowposts. There was no significant difference between the retention of stainless steel Paraposts and any of the other groups. CONCLUSIONS: Serrated parallel-sided stainless steel posts were no more retentive than either parallel-sided or tapered tooth-colored posts in this study. When all groups were considered, post dimension appeared to influence retention, with parallel-sided posts being more retentive than tapered posts.  相似文献   

8.
PURPOSE: This study evaluated the retention of prefabricated parallel-sided dowels luted with resin cement in extracted teeth that were obturated with gutta percha using a eugenol sealer or a calcium hydroxide sealer. MATERIALS AND METHODS: Extracted maxillary incisor roots (N = 51) were instrumented to simulate conventional root canal therapy and divided into 3 groups (n = 17). One group was not obturated. Second and third groups were obturated with gutta percha using a eugenol-containing or calcium hydroxide-containing sealer. Gutta percha was removed using a heated plugger, and dowel spaces were prepared to a 7 mm depth. Dowel space walls were acid etched and primed, and prefabricated stainless steel dowels were luted using resin cement. After 24 hours, the load required to dislodge each dowel along a path parallel to its long axis was measured and recorded. A one-way analysis of variance (alpha = 0.05) was performed to identify differences in the means among groups. The incidence of failure within the cement or at the dentin-cement interface was also recorded. RESULTS: No statistically significant difference was found among the control (159.9 +/- 96.3 N), eugenol sealer (153.1 +/- 77.3 N), and calcium hydroxide sealer (192.0 +/- 89.3 N) groups. Nearly all specimens displayed adhesive failure at the dentin-resin cement interface. CONCLUSIONS: Conventional endodontic obturation using a eugenol-containing or a calcium hydroxide-containing endodontic sealer did not affect retention of prefabricated stainless steel dowels luted with resin cement.  相似文献   

9.
Purpose: Practitioners have several options during the selection of a dowel for core restoration, including metal and glass fiber materials. Retention of the cemented dowel is critical for the success of this type of restoration. The purpose of this in vitro study was to evaluate the effect of two surface treatments on the retention of three types of dowels placed into prepared canals with a resin cement.
Materials and Methods: Following the removal of the clinical crown, gutta percha was used to restore canals prepared to size 40 in 90 extracted human anterior teeth. The access openings were then sealed, and the teeth stored in water for 3 weeks at 37°C. Post preparations were made to a depth of 9 mm, and parallel ParaPost, FibreKleer, and FibreKor dowels were each used to restore 30 teeth. Ten dowels in each group received no surface roughening treatment, 10 were air abraded with 50 μ aluminum oxide, and 10 were air abraded with CoJet. The specimens were stored in water for 24 hours at 37°C following dowel placement and prior to debonding with an Instron Testing Machine.
Results: The forces (N) required in tensile load to dislodge the dowels for each group were: ParaPost/CoJet 214.04 ± 91.72, FibreKleer/AlOxide 196.07 ± 57.69, ParaPost/AlOxide 184.46 ± 35.05, FibreKleer/CoJet 176.36 ± 42.43, FibreKor/AlOxide 174.32 ± 53.64, ParaPost/Unroughened 174.14 ± 40.74, FibreKor/CoJet 167.16 ± 35.94, FibreKor/Unroughened 116.69 ± 37.01, and FibreKleer/Unroughened 96.88 ± 33.45. Post hoc analysis demonstrated that the unroughened FibreKor and FibreKleer dowels had significantly less retention than all other test groups ( p ≤ 0.05).
Conclusion: Surface roughening with air abrasion increases retention in dowels cemented with a resin cement. Both the aluminum oxide and CoJet systems were equally effective in this regard.  相似文献   

10.
Purpose: This study had two aims: (1) to compare the retention of a flexible directly placed fiber‐bundle dowel system with that of a rigid prefabricated fiber‐reinforced composite (FRC) dowel system, and (2) to determine the effect of decreasing the volume of luting cement around the flexible fiber‐bundle dowels on the axial retention of the restorations. Materials and Methods: Single‐canal premolars (n = 36) were decoronated, cleaned, shaped, and prepared for both flexible and rigid dowels to a depth of 10 mm using a size 2 drill. The roots were then randomly allocated into three groups: Ia, Ib, and II (n = 12). Flexible fiber‐bundle dowels were placed in groups Ia and Ib. These were available in three fiber‐bundle diameters: small (0.9 mm), medium (1.2 mm), and large (1.5 mm). These bundles were luted in the root canals with Variolink II. The differences between Ia and Ib were in the ratio of the volume of fiber‐bundles to the volume of luting cement and in the mode of application. Medium fiber‐bundles were placed to the end of the preparation in groups Ia and Ib; however, in group Ia, a small diameter auxiliary bundle was placed, whereas in group Ib, a large‐diameter auxiliary bundle was cut axially into strips of circa 0.2‐mm thickness before being sequentially overlapped in placement. Roots in group II were restored with size 2 rigid prefabricated fiber dowels and luted with the light‐cured cement provided by the manufacturer. After 24 hours of storage, axial tensile forces were applied to all luted dowels progressively to failure at 0.5 mm/min. Data were analyzed using a one‐way analysis of variance (ANOVA) and the Bonferonni test. Results: The mean axial resistance forces (standard deviation [SD]) for groups Ia, Ib, and II were not statistically different at 166 (49), 157 (36), and 151 (44) N, respectively (p > 0.05). Conclusions: There was no significant difference between the retention of the flexible fiber‐bundle dowel system and that of the rigid prefabricated fiber dowel system. Decreasing the volume of luting cement around the flexible dowels did not have a significant effect on the axial retention of the restorations.  相似文献   

11.
Due to extensive loss of tooth substance the restoration of endodontically treated tooth requires intracanal dowels to give an efficient strength for the crown. The aim of our study was to investigate whether the previous type of restoration of the tooth, i.e. composite restoration with screw post versus one-piece dowel crown, has an effect on the prognosis of crowns with dowels. The material consisted of 111 single crowns and as a previous restoration there were 83 composite restorations with screw posts and 28 one-piece dowel crowns. The mean follow-up time was 78 months (range 6--163 months). The cumulative survival was 87% for one-piece dowel crowns and 84% for composite resins with screw posts. There were six root fractures, four losses of cement retention and one tooth extraction due to caries in crowns with previous composite resin with screw posts. In one-piece dowel crowns as a previous restoration there were two root fractures and one tooth extraction for periodontal reasons. In conclusion, it seems that the previous restoration has no marked effect on the prognosis of crowns with dowels when studying a composite resin restoration with screw post and a one-piece dowel crown.  相似文献   

12.
STATEMENT OF PROBLEM: Endodontically-treated, dowel-restored teeth may experience fracture, but investigations of variables related to fracture are often inconclusive and occasionally contradictory. PURPOSE: The finite element method was used to analyze the stresses in dowel-restored teeth. The variables studied were material, shape, bonding, modulus of elasticity, diameter, and length of the dowel. MATERIAL AND METHODS: The model of the dowel-restored tooth involved dentin, ligament, cortical and trabecular bone, gingiva, and gutta-percha. The dowels were made of glass fiber, titanium, or zirconia and modeled as an approximation of the brands ParaPost Fiber White, ParaPost XH, and Cerapost, respectively. The dowel was cemented with zinc-phosphate cement or with bonded or nonbonded resin luting agents, and an approximation of the material properties of these 2 materials were used in the modeling. The restoration included a composite resin core and a gold crown. Other variables included taper versus parallel-sided posts, modulus of elasticity, diameter, and length of post. The model was axisymmetrical in 3 dimensions. A load of 100 N was applied to the crown at an angle of 45 degrees, and tensile, shear, and von Mises stresses were calculated. RESULTS: The generated stresses decreased with respect to the dowel material in the following order: glass fiber, titanium, and zirconia. Stresses were in general higher with tapered than with parallel-sided dowels. Stresses were reduced by bonding and with an increasing modulus of elasticity, increasing diameter, and increasing length of the dowel. CONCLUSIONS: Within the limitations of this study, it was found that all investigated dowel-related factors influenced the stress field generated in dowel-restored teeth.  相似文献   

13.
STATEMENT OF PROBLEM: Luting material, surface properties, and loading conditions affect the retention of prefabricated dowels to varying degrees. PURPOSE: The purpose of this study was to evaluate the effect of roughening of the dentinal walls and artificial aging on the retention of prefabricated tapered titanium dowels, using 4 different luting materials. MATERIAL AND METHODS: One-hundred twenty-eight single-rooted teeth were selected, the coronal aspect of each tooth was removed, and the remaining root received endodontic therapy. All specimens were divided into 4 groups (n=32). Dowel spaces were prepared to a depth of 10 mm using ISO 90 rotary cutting instruments. Tapered titanium dowels were luted with the following luting materials: zinc-phosphate cement (Harvard cement), glass-ionomer cement (Ketac Cem EasyMix), resin composite luting agent (Panavia 21) with autopolymerizing dentin primer (ED-Primer), or a self-adhesive composite luting agent (RelyX Unicem). Both composite luting agents were used without acid etching of the canal dentin. Each luting agent was used under 2 conditions: in 1 subgroup (n=16) the dentinal walls were not roughened, and in the other subgroup (n=16), walls were roughened with a diamond rotary cutting instrument. Eight specimens from each subgroup were stored in water at 37 degrees C for 3 days; the other 8 specimens were stored for 150 days and subjected to simulated aging conditions using 37,500 thermal cycles (5 degrees C/55 degrees C) and 300,000 mechanical loading cycles with 30 N. Dowel retention (N) was measured using a universal testing machine with a crosshead speed of 2 mm/min. Data were analyzed using 2- and 3-way ANOVAs and the Tukey HSD test (alpha=.05). RESULTS: The dislodged dowels were examined microscopically to evaluate mode of failure. The nonroughened dentinal walls showed no significant differences between the different luting agents. Roughening the dentinal walls increased the retention significantly for all groups. This increase was significantly higher for the resin composite groups (P=.0001). Storage for 150 days with thermal cycling and mechanical loading caused a significant decrease in dowel retention (P=.001). The failure mode was purely adhesive at the luting material-dentin interface for all dowels cemented in nonroughened root canals. A mixed failure mode, adhesive at the luting material-dentin interface and cohesive in the luting material, was observed for dowels cemented in roughened root canals. CONCLUSION: Roughening the dentinal walls and the use of resin luting cements provided statistically significant increases in dowel retention values.  相似文献   

14.
STATEMENT OF PROBLEM: No clear consensus exists regarding the choice of luting agents for the retention of cast metal dowels used as a treatment alternative for endodontically treated teeth with excessive loss of coronal tooth structure. PURPOSE: The purpose of this in vitro study was to investigate the retention of the dowel/luting agent/tooth complex while applying different luting agents to cast metal dowels under vertical tensile loading. MATERIAL AND METHODS: Sixty extracted, noncarious mandibular premolars with roots of approximately 15-mm length were selected. For each tooth, a tapered root canal preparation was completed to a maximum diameter of 1.60 mm and a length of 11 mm, a common clinical configuration to accommodate cast metal dowels. Sixty cast metal dowels were fabricated for the tooth specimens and cemented with 1 of 3 luting agents (n = 20): zinc-phosphate cement (ZPC) as a control, phosphate-methacrylate resin luting agent (PMRL, Panavia F), and phosphate-methacrylate resin luting agent with metal dowel surfaces modified with a silane coating technique (PMRLS, Panavia F + Siloc). Tensile bond strength (TBS) of the specimens was measured with a universal testing machine at a crosshead speed of 0.5 mm/min. Data (kg) were statistically analyzed using a 1-way analysis of variance and a Scheffe multiple range test (alpha=.05). The homogeneity of variances was analyzed using the Levene test. RESULTS: The TBS values of ZPC (34.2 +/- 10.54 kg) were significantly higher than PMRL (22 +/- 9.57 kg) and PMRLS (21.7 +/- 7.64 kg). There was no significant difference between the PMRL and PMRLS groups. CONCLUSION: Within the limitations of this study, the use of zinc-phosphate cement provided greater TBS for cast metal dowels than the resin luting agent with and without the silane coating technique. The TBS values with and without the silane coating technique were not statistically different.  相似文献   

15.
PURPOSE: This study compared the tensile retentive strength of composite fiber-reinforced dowels luted with a resin cement to stainless steel dowels luted with zinc phosphate cement. MATERIALS AND METHODS: The crowns of 40 extracted human mandibular premolars were removed with a separating disc 1-mm coronal to the cementoenamel junction. The teeth were randomly divided into 4 groups (n = 10). A post space was prepared in each specimen to a depth of 9 mm, using the drill supplied by the respective manufacturer. For the stainless steel post group, 1.25-mm-diameter posts were cemented with zinc phosphate cement. For the composite fiber reinforced groups, posts with diameters of 1.00, 1.25, and 1.50 mm were luted with a Bisphenol A-Glycidyl Methacrylate (BIS-GMA) resin bonding system (Jeneric/Pentron, Wallingford, CT) according to manufacturer specifications. The specimens were stored in a sealed container with a moist environment for 24 hours, placed in a fixture in an 801 Materials Test Systems (MTS) machine (MTS Systems Corp, Minneapolis, MN), and loaded in tension at a rate of 5.0 mm/min until failure. Differences among the 4 groups were determined using a one-way analysis of variance and Tukey-B post-hoc tests (alpha = 0.05). RESULTS: The mean loads to failure ranged from 43.9 +/- 10.4 kg for the stainless steel dowel group to 19.9 +/- 5.7 kg for the composite fiber-reinforced 1.00-mm-diameter group. The stainless steel post luted with zinc phosphate cement provided significantly greater tensile resistance than all composite fiber dowel groups. The retention of the 1.00-mm composite fiber-reinforced post was significantly less than the remaining groups. CONCLUSIONS: Under the conditions of this study, the stainless steel dowel luted with zinc phosphate cement provided significantly greater retention.  相似文献   

16.
Dowel retention with glass-ionomer cement.   总被引:1,自引:0,他引:1  
The retentive capacity of the Whaledent Parapost system utilizing ASPA cement was compared at two lengths, three diameters, and with respect to the effect of both medication and citric acid pretreatment. The greatest single factor influencing retention was embedment depth into dentin. No significant differences were observed between the retention values for medicated and unmedicated teeth. Finally, no increase in retention was noted over previously reported values for zinc phosphate, carboxylate, and epoxy resin cements. The glass-ionomer cement tested offers no advantage for post retention.  相似文献   

17.
Purpose: Previous clinical studies indicated loss of retention between dowel and tooth was a major cause of failure for passive endodontic dowels. Advances in luting cement technology may have improved the retention of dowels. The purpose of this systematic review was to determine the clinical failure modes for dowel/core/crown restorations luted using resin‐based cements that are either self‐etching or used in conjunction with a bonding agent. Materials and Methods: PubMed was searched for English language, peer‐reviewed clinical research following restorations for 2 years or longer. For inclusion, a study group must have followed more than 50 permanent teeth restored using a dowel luted with resin cement and a bonding agent. Furthermore, more than 80% of the restorations must have received a nonresin crown. Results: Fifteen studies met the inclusion criteria and reported a total of 187 failures from 3046 restorations. The commonly reported causes of failure were dowel debonding (37% of all failures and primary cause in 8 of the 17 reporting study groups) and endodontic lesions (37% of all failures and primary cause in 6 of the 11 reporting study groups). Conclusions: Loss of retention remains a major mode of failure even for passive, nonmetal dowels luted by resin cements with a bonding agent. The exact nature and underlying causes of debonding have not been adequately investigated.  相似文献   

18.
目的:探索铸造金属桩核制作方法、粘接方法和粘接剂种类对其固位的影响。方法:选择80颗完整的新鲜无龋坏下颌单根管双尖牙,在釉牙骨质界上2 mm处去除临床牙冠,行根管治疗,根管预备和铸造桩核制作及粘接。根据制作方法将80个样本分为两大组(直接法和间接法),每组40个。每组又根据粘接方法(使用螺旋输送器和未使用)和粘接剂(玻璃离子水门汀和磷酸锌水门汀)不同下分4小组,每组10个样本。将样本置于23 ℃室温生理盐水中存放24 h后放置于万能力学测试机上,以0.5mm/min的速度进行拉力试验直到失败,从而得出固位力大小。结果:本实验中影响固位力的最明显因素为粘接方法,使用了螺旋输送器组的固位力明显高于未使用螺旋输送器组(P<0.05);不同制作方法对固位力无明显影响(P>0.05),使用磷酸锌粘接剂组固位力高于使用玻璃离子粘接剂组。然而制作方法,粘接方法和粘接剂种类间是有密切的交互作用的(P<0.05)。结论:制作方法并不影响铸造桩核的固位力,磷酸锌粘接剂性能优于玻璃离子粘接剂,粘接方法对固位力有显著的影响,建议在粘接过程中使用螺旋输送器。  相似文献   

19.
Retention of a core material supported by three post head designs   总被引:3,自引:0,他引:3  
STATEMENT OF PROBLEM: There are few studies on the retention of core build-up materials to prefabricated post head designs, especially for a new ceramic post design. PURPOSE: This in vitro study compared the retention of 2 types of core build-up materials (Ti-Core titanium-reinforced composite and a GC Miracle Mix silver-reinforced glass ionomer) supported by 3 post head designs (Flexi-Post, AccessPost, and Cerapost dowel). For all test groups, heads of the posts were placed into the core material at a 90-degree angle to the surface. Test specimens (unloaded) were then placed into a special jig and retention test was performed using an 810 MTS testing machine.Material and Methods: This study consisted of 6 groups with 10 specimens per group. A 3 x 2 factorial design was used to test for statistical significance and results were considered significant when P <.05. RESULTS: Results of the retention test were as follows: group 1, Flexi-Post/Ti-Core 220.0 lb (982.1 N), group 2, AccessPost/Ti-Core 212.7 lb (949.6 N), group 3, Cerapost/Ti-Core 41. 8 lb (186.6 N), group 4, Flexi-Post/Miracle Mix 43.4 lb (193.8 N), group 5, AccessPost/Miracle Mix 61.6 lb (275 N), and group 6, Cerapost/Miracle Mix 7.5 lb (33.5 N). Results of the ANOVA revealed a highly significant difference between posts and cores (P <.0001). CONCLUSION: Post head designs of the stainless steel AccessPost and Flexi-Post dowels offers greater retention then the smooth ceramic head design of the Cerapost dowel. In addition, the composite core material (Ti-Core) offers greater retentive strength values than the glass ionomer material (Miracle Mix).  相似文献   

20.
The effects of lubrication on the retention of parallel-sided and tapered cast post and cores cemented with zinc phosphate-cement (ZnPO4) and glass ionomer cements were investigated. Seventy-two maxillary canine teeth of similar size were selected for direct, parallel-sided post and core castings. The canines were sectioned at the cementoenamel junction and mounted in resin blocks. A post space was prepared to 1.5 mm (d) x 10 mm (I) with a handpiece mounted in a surveyor. The teeth were divided into four groups: ZnPO4 without lubricant, ZnPO4 with lubricant rinsed with water, ZnPO4 with lubricant removed by solvent, and ZnPO4 with solvent alone. The same four groups were made by using glass ionomer cement. Retention was tested with a 4200 series Instron machine by pulling the castings out of the teeth. There were no significant differences in retention among the eight groups of parallel posts at alpha = 0.05. The testing procedure was repeated by using an 11 mm post with 6 degrees of taper. With tapered posts, a statistically significant reduction in retention was found in the lubricated samples when compared to the nonlubricated samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号