首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 188 毫秒
1.
李海燕  孙同  李莹 《眼科新进展》2007,27(10):764-766
目的探讨应用VISX Custom Vue系统进行波前像差引导的LASIK手术的角膜组织切削深度,并与标准LASIK手术的角膜切削深度进行比较。方法选择接受Custom Vue个体化LASIK手术的近视患者54例102眼,记录术中角膜切削深度;同时根据患者的术前验光,应用VISXStar S4OPM模拟软件,计算这些患者进行标准LASIK所需要的角膜切削深度,并对Custom Vue切削深度与标准切削深度进行比较。结果54例102眼中,Custom Vue实际切削深度为(99.65±22.82)μm。应用6.0mm光学区和8.0mm修边区的标准LASIK的最大切削深度为(75.40±20.03)μm;6.5mm光学区和8.0mm修边区的最大切削深度为(86.04±23.46)μm。CustomVue实际切削深度比标准LASIK切削深度增加(34.5±19.0)%(t=24.620,P=0.000)。Custom Vue实际切削深度比大光学区LASIK切削深度增加(18.1±16.9)%(t=13.643,P=0.000)。结论应用CustomVue进行个体化LASIK手术,对角膜的切削深度要高于同等大小光学区的标准LASIK手术。在考虑进行波前像差引导的个体化切削时,应该注意考虑患者的角膜厚度。  相似文献   

2.
目的比较常规准分子激光原位角膜磨镶术(Laser in situ Keratomileusis,LASIK)和角膜波前像差引导的个性化准分子激光原位角膜磨镶术(corneal wavefront aberrations guidedL ASIK,CW-GLASIK)治疗近视眼术后患者视觉质量的变化,探讨角膜波前像差引导的个性化准分子激光原位角膜磨镶术对对比敏感度和眩光以及角膜波前像差的影响,评价其手术的有效性。方法选取拟做LASIK手术的近视眼患者(近视球镜≤-10.00D,散光≤-2.5D)随机分成两组,一组行常规LASIK手术,另一组行角膜波前像差引导的个性化LASIK手术,手术均采用德国Schwind公司Esiris’准分子激光治疗系统,微角膜刀采用Moria LSK-ONE气动平推刀,对比敏感度检查采用Vector Vision CSV-1000HGT,角膜波前像差分析采用德国OPTIKON 2000 Keratron Scout分析仪。手术光学区直径为(6.0-7.0)mm,波前像差分析为6mm瞳孔直径。术前、术后检查裸眼视力、屈光度、对比敏感度及角膜地形图并进行波前像差分析。结果术后两组的裸眼视力均达到术前矫正视力,无显著性差异(P〉0.05)。两组术后1m时对比敏感度及眩光和术前比较均明显下降,差异有显著性(P〈0.05),术后3m时各空间频率对比敏感度和眩光均有所恢复,但均未达到术前水平,角膜波前像差引导的个性化LASIK组在各空间频率的对比敏感度和眩光同术前比较,无显著性差异,LASIK组在各空间频率的对比敏感度和眩光和术前比较差异有显著性(P〈0.05),角膜波前像差引导的个性化LASIK组在中(6c/d)、高(12c/d、18c/d)空间频率的对比敏感度和眩光明显好于常规LASIK组,有显著性差异(p〈0.05)。两组术后1m、3m角膜彗差、球差均比术前增大,但角膜波前像差引导的个性化LASIK组较常规LASIK组增大幅度小,差异有统计学意义(P〈0.05)。结论角膜波前像差引导的LASIK手术能有效地矫正近视,改善近视眼患者术后对比敏感度,降低术后彗差和球差,手术效果稳定、安全。  相似文献   

3.
目的:观察博士伦Zyoptix节约角膜个体化LASIK治疗近视的临床效果,同时分析术后高阶像差的变化。方法:因角膜相对较薄不适宜接受常规LASIK手术,而采用Zyoptix节约角膜个体化LASIK治疗的患者32例64眼,分析节约角膜的程度、术后1a余视力的恢复和6mm瞳孔直径下高阶像差的变化。结果:手术平均节约角膜组织29.27μm,节约组织达21.36%;术后1a余,裸眼视力为0.93±0.24,较术前裸眼视力显著提高(P<0.01),与术前最佳矫正视力0.96±0.09相似,比较无统计学差异;81%的眼裸眼视力≥术前最佳矫正视力,无1眼最佳矫正视力下降。在6mm瞳孔直径下,总体高阶像差、三阶彗差、四阶球差较术前分别增大1.76倍、2.10倍、3.90倍,与常规LASIK术相似。结论:Zyoptix节约角膜个体化LASIK可以节约角膜组织20%~25%,扩大近视治疗度数范围,临床上有良好的安全性、有效性和预测性。  相似文献   

4.
目的 探讨近视LASIK术后角膜高阶像差的变化情况.方法 回顾性分析近视LASIK手术患者75例145只眼,比较患者术前术后角膜非球面系数(Q值)、总体高阶像差均方根值(RMSh)、3~7阶像差均方根值(RMS3-RMS7)、球差、慧差、三叶草像差等数值,用多元线性回归分析筛选引起术后角膜高阶像差改变的因素.结果 术前角膜高阶像差与年龄无相关关系;术后各观察值的大小主要受术前相应各数值的大小、预矫屈光度数、切削区大小等因素的影响,术前值越大、预矫屈光度越大以及切削区越小,术后角膜高阶像差值越大;术后Q值、RMSh以及球差的增加量主要受预矫屈光度数和切削区大小的影响;慧差以及三叶草像差的增加与切削区大小无关.使用较小切削区(5.25mm)时的单位屈光度矫正引起的高阶像差增加值以及角膜前表而非球面系数改变值高于使用较大切削区时,差异有统计学意义.结论 LASIK术后角膜高阶像差增大,预矫屈光度数高和切削区小是引起术后角膜高阶像差增加较大的主要原因.  相似文献   

5.
目的比较常规准分子激光原位角膜磨镶术(laserin situ keratomileusis,LASIK)和角膜波前像差引导的优化屈光角膜切削术(optimized refractive keratomy,ORK)后近视眼患者视力及角膜前表面高阶像差的变化,探讨角膜波前像差引导的优化准分子激光原位角膜磨镶术(ORK-LASIK)的安全性和有效性。方法选取拟做LASIK手术的近视眼患者396例733眼,按球镜屈光度分成低度(≤-3.00D)、中度(-3.00~-6.00D)和高度(-6.00~-12.00D)3组,每组柱镜度数均小于-2.50D,各组再随机分成2组,一组行常规LASIK手术,另一组行ORK-LASIK。手术切削区直径为6.0~7.0mm。角膜波前像差分析为6mm瞳孔直径。术后随访6个月,检查裸眼视力及角膜地形图并进行波前像差分析。结果成人近视眼角膜前表面波前像差在6mm瞳孔直径以3阶和4阶为主,占90%,在3阶和4阶中又以彗差和球差为主,分别占角膜全部像差的27.7%和28.4%;球差和球镜度数呈负相关(r=-0.501,P〈0.05),其他高阶像差和球镜度数无关。但在-6.00D以上的近视眼中,彗差和次级彗差均和球镜度数有关(F=8.808,7.123,P〈0.04,0.01)。角膜前表面各高阶像差均和年龄及性别无关。LASIK和ORK-LASIK2组比较,术后6个月时,低度和高度组2组的裸眼视力均达到术前矫正视力,差异无统计学意义(P〉0.05);在中度组,ORK-LASIK组视力明显好于LASIK组,2组差异有统计学意义(P〈0.05)。术后6个月时,角膜前表面的球差、彗差和总高阶像差均较术前增加,和术前比较差异有统计学意义(P〈0.05)。在低度组,ORK-LASIK组和LASIK组比较角膜彗差和球差2组间差异无统计学意义(P〉0.05);中、高度组ORK-LASIK组角膜彗差和球差较LASIK组明显下降,差异有统计学意义(P〈0.05)。结论角膜波前像差引导的ORK-LASIK手术能有效地矫正近视和散光,提高中度近视患者的视力,降低中、高度组术后彗差和球差,手术效果稳定、安全。  相似文献   

6.
目的:探讨波阵面像差引导的准分子激光原位角膜磨镶术(laser in situ keratomileusis,LASIK)和准分子激光角膜上皮瓣下磨镶术(laser epithel ialkeratomileusis,LASEK)对近视眼高阶像差的影响,并作对比分析。方法:波阵面像差引导的LASIK手术(IK组)共18例36眼和波阵面像差引导的LASEK手术(EK组)共10例20眼,分别于术前和术后10d;1,3mo测量高阶像差,用t检验分析手术前后高阶像差的变化和不同手术方式对高阶像差影响。结果:两组术后总高阶像差RMS值均较术前增加,以三、四阶像差增加为主,五、六阶像差和水平彗差无明显变化;两组的球差均较术前增加,两组间无差异;术后EK组的总高阶像差、三阶、四阶像差和垂直彗差均小于IK组。结论:波阵面像差引导的LASIK和LASEK都会使眼高阶像差不同程度的增加,LASEK的增加幅度小于LASIK。  相似文献   

7.
目的:比较分析角膜表层与基质层屈光手术后高阶像差及其变化值。方法:行准分子激光治疗的近视眼患者100例200眼,其中接受LASIK手术50例100眼,接受新型表层手术(ASA)50例100眼。LASIK手术组术前等效球镜度(SE)为-1.25~-9.25(平均-5.75±1.74)D,ASA手术组术前SE为-2~-9.25(平均-5.42±1.81)D。术前及术后1,3,6mo检查裸眼视力(UCVA)、最佳矫正视力(BSCVA)、球镜及柱镜度数、SE以及波前像差等。结果:C7,C12,RMS3,RMS4,RMS5,RMS6和RMSh的变化值均和球镜度变化值、SE变化值的绝对值显著正相关。术后1mo,ASA组C7绝对值、RMSh,RMS3和RMS6均显著小于LASIK组;术后3mo时,ASA组C7和C14显著小于LASIK组,LASIK组C12显著小于ASA组;术后6mo时,ASA组仅C14显著优于LASIK组。术后1mo时,ASA组RMS3,RMS5,RMS6和RMSh的变化值均显著小于LASIK组,术后3mo时,ASA组RMS6变化值显著小于LASIK组,术后6mo时,ASA组RMS3,RMS6和RMSh的变化值显著小于LASIK组。结论:高阶像差增大程度与球镜度及SE的变化程度正相关。ASA组术后高阶像差及其增大程度均小于LASIK组,术后6mo时两组差异仍显著。  相似文献   

8.
各空间频率对比敏感度均恢复至术前水平;术后问卷表示"满意"和"非常满意"者试验组为50眼(96.1%),对照组为46眼(92.0%).结论 虹膜定位联合波前像差引导的LASIK的术后视觉质量略优于常规波前像差引导的LASIK.[眼科新进展 2009;29(9):697-699]  相似文献   

9.
近视眼LASIK手术前后角膜波阵面像差和地形图的变化   总被引:3,自引:12,他引:3  
目的:探讨LASIK矫治近视眼前后角膜前表面波阵面像差与地形图的变化及影响因素.方法:术后裸眼视力1.O以上,接受LASIK矫治的近视者100例200眼.回顾术前和术后1mo时使用Optikon-2000角膜地形图仪测得的角膜地形图和角膜波阵面像差数据.记录角膜测量区为3.0,4.5,6.0mm时术前和术后Zernike多项式系数的变化,分析切除区大小对角膜波阵面像差测量结果的影响,以及角膜地形图与角膜波阵面像差的相关性.结果:角膜测量区直径为3.0,4.5,6.0mm时,分别有4,8,9项Zernike系数手术前后的差别具有显著性或非常显著性.当测量区的直径在4.5mm和6.0mm时,RMS的增大均有显著的意义(P<0.05,P<0.01).角膜切除区直径小于测量直径时,术后RMS的增大有非常显著性(P<O.01).角膜地形图参数BFC和BFIT分别与角膜波阵面像差的散光和RMS成正相关(r=0.6756,P<0.001;r=0.6076,P<0.001).结论:LASIK矫治近视眼术后角膜前表面波阵面像差的增大与角膜测量直径有关,角膜地形图参数BFC和BFIT变化能反映角膜波阵面像差散光和RMS的变化.  相似文献   

10.
LASIK治疗近视后切削中心的角膜地形图观察   总被引:6,自引:0,他引:6  
目的评价准分子激光角膜原位磨镶术(Laser in situ keratomileusis,LASIK)矫治近视眼术后切削中心的偏移对术后最佳矫正视力的影响.方法应用角膜地形图仪对185例(356眼)LASIK术后随访6个月以上的术前、术后角膜地形图进行观察分析,测量准分子激光切削中心相对于瞳孔中心的距离、方向,并用视功能进行比较.结果激光切削中心相对于瞳孔中心的距离平均偏心值为0.38±0.26mm;其中偏离瞳孔中心0.5mm以内为263眼(73.9%),0.5~1.0mm为85眼(23.9%),1.0~1.2mm者为8眼(2.2%),切削中心位于鼻侧者为320眼(89.9%).偏中心切削致术后最佳矫正视力下降1~3行偏心量≤0.5mm中、小光区切削9眼,偏心量>0.5mm为27眼.结论严重的偏中心切削将导致术后裸眼视力和最佳矫正视力下降,准确的切削中心定位和在条件允许情况下,适当扩大切削直径以及完整的角膜瓣对LASIK术后的效果应是十分重要的.  相似文献   

11.
AIM: To evaluate and compare the efficacy of the astigmatic correction achieved with laser in situ keratomileusis (LASIK) in eyes with myopic astigmatism using wavefront-guided (WFG) and wavefront-optimized (WFO) ablation profiles. METHODS: Prospective study included 221 eyes undergoing LASIK: 99 and 122 eyes with low and moderate myopic astigmatism (low and moderate myopia groups). Two subgroups were differentiated in each group according to the ablation profile: WFG subgroup, 109 eyes (45/64, low/moderate myopia groups) treated using the Advanced CustomVue platform (Abbott Medical Optics Inc.), and WFO subgroup, 112 eyes (54/58, low/moderate myopia groups) treated using the EX-500 platform (Alcon). Clinical outcomes were evaluated during a 6-month follow-up, including a vector analysis of astigmatic changes. RESULTS: Significantly better postoperative uncorrected visual acuity and efficacy index was found in the WFG subgroups of each group (P≤0.041). Postoperative spherical equivalent and cylinder were significantly higher in WFO subgroups (P≤0.003). In moderate myopia group, a higher percentage of eyes with a postoperative cylinder ≤0.25 D was found in the WFG subgroup (90.6% vs 65.5%, P=0.002). In low and moderate myopia groups, the difference vector was significantly higher in the WFO subgroup compared to WFG (P<0.001). In moderate myopia group, the magnitude (P=0.008) and angle of error (P<0.001) were also significantly higher in the WFO subgroup. Significantly less induction of high order aberrations were found with WFG treatments in both low and moderate myopia groups (P≤0.006). CONCLUSION: A more efficacious correction of myopic astigmatism providing a better visual outcome is achieved with WFG LASIK compared to WFO LASIK.  相似文献   

12.
目的 :观察准分子激光原位角膜磨镶术 (Laserinsitukeratomileusis ,LASIK)不同位置角膜瓣蒂的疗效。方法 :将 2 18例 43 6眼行LASIK的近视患者按角膜瓣蒂位置分为鼻侧和上方两组。对术中操作和术后疗效进行比较观察。结果 :术后 3个月裸眼视力鼻侧和上方蒂角膜瓣组分别为 1 0 7± 0 2 4和 1 0 8± 0 19两组无明显差异 (t =0 72 ,P >0 0 5 )。术后出现散光鼻侧蒂瓣组有 2 7眼 (12 3 8% )上方蒂瓣组 2 1眼 (9 6% )。术后鼻侧蒂瓣有 3眼发生角膜瓣移位。结论 :鼻侧和上方角膜瓣组均具有良好的术后效果 ,两组无明显差异 ,但在操作掌握和术后角膜瓣稳定性上 ,上方瓣优于鼻侧瓣  相似文献   

13.
目的 比较OrbscanⅡ测量准分子激光原位角膜磨镶术(LASIK)前后周边角膜后表面曲率半径改变,初步确立新的角膜前后表面曲率半径比率R,利用术后周边后表面角膜曲率半径和比率R估算术前角膜总屈光力。方法 回顾分析OrbscanⅡ测量151只眼术前及术后3个月角膜7~10 mm区后表面曲率半径值的变化,计算角膜0~~7 mm区前表面曲率半径与角膜7~10 mm区后表面曲率半径比率R,利用比率R推算30只眼术前角膜总屈光力,并验证计算性角膜总屈光值与测量性角膜总屈光值的一致性。LASIK手术前后角膜7~10 mm后表面曲率半径变化和计算性角膜总屈光力与术前OrbscanⅡ测得角膜总屈光力比较采用配对t检验。结果 LASIK术前后角膜7~10 mm区后表面曲率半径差值为(-0.005±0.154)mm(t=0.417,P=0.677),术前角膜0~7 mm区前表面曲率半径与角膜7 ~ 10 mm区后表面曲率半径比率R为1.167±0.030,利用比率R推算的角膜总屈光力均值为(43.49±1.79)D,OrbscanⅡ测得实际角膜总屈光力均值为(43.77±1.53)D,两者差值均值为(-0.28±1.00)D(t=-1.523,P=0.139)。结论 LASIK手术前后周边区域角膜后表面曲率半径改变无实际临床意义,计算所得新角膜前后表面曲率半径比率R可准确的推算LASIK术者术前角膜总屈光力,为LASIK术后丢失术前资料患者双K法计算人工晶状体度数提供重要条件。  相似文献   

14.
LASIK手术对角膜内皮细胞影响的研究   总被引:2,自引:0,他引:2  
目的 研究 L ASIK手术对角膜内皮细胞的影响。方法  5 1例 96眼近视眼患者进行 L ASIK治疗 ,等效球镜度数 - 1.5 0 D~ - 15 .75 D(- 6 .92± 3.43D) ,并按照准分子激光切削后角膜基质床的厚度分别分成三组 : .2 0 0~ 2 5 0μm ; .2 5 0~ 30 0μm; .30 0μm以上。各组患眼于术前和术后 3个月进行角膜内皮镜检查 ,观察角膜内皮细胞形态和内皮细胞密度。结果  L ASIK手术前后角膜内皮细胞形态结构无明显改变 ,术前、术后角膜内皮细胞密度分别为 316 5± 32 4/ mm2 和 315 1± 30 5 / mm2 ,配对 t检验 ,无显著性差异 (P >0 .0 5 )。按照激光切削后角膜基质床的厚度分成的三组术前、术后角膜内皮细胞密度也没有出现显著性改变 (P >0 .0 5 )。结论  L ASIK术后早期不会损伤角膜内皮 ,不会造成中央部角膜内皮细胞密度降低和细胞形态结构的改变 ,其对角膜内皮细胞的远期影响有待进一步的观察。  相似文献   

15.
目的研究准分子激光角膜原位磨镶术(laser insitu keratomileusis,LASIK)前后角膜像差的改变。方法对53例103眼施行LASIK手术的近视眼患者,采用角膜地形图及角膜像差系统检测术前、术后1周、术后1月角膜像差,分别记录直径为5mm、6mm、7mm时的角膜彗差、球差、总均方根值。结果角膜球差、彗差、总均方根术后均增加,术前、术后之间均有统计学差异(P<0.01),而术后1周与1月之间无统计学差异(P>0.05),且差值均随直径增大而增大;术后总均方根在角膜直径为5mm时较术前减小。结论研究的角膜范围越大,得出的角膜高阶像差值越大;术后除5mm范围内的总均方根值下降外,其余数值均高于术前;角膜彗差、球差、总均方根值在LASIK术后1周已基本趋于稳定。角膜像差的研究对指导个体化的近视激光治疗有着非常重要的意义。  相似文献   

16.
准分子激光原位角膜磨镶术对角膜内皮细胞的影响   总被引:1,自引:0,他引:1  
目的探讨准分子激光角膜原位磨镶术(LASIK)后角膜厚度及角膜内皮细胞的变化。方法近视眼行LASIK手术157例(306只眼),按术前是否配戴角膜接触镜(CL)分为A、B两组:A组未配戴CL,共98例(190只眼);B组配戴CL并于停戴2周后接受手术,共59例(116只眼)。术前等值球镜屈光度~5.00 D~1500D,平均为(~8.24±1.23)D,切削深度平均为(123±20.37)μm。分别于术前和术后3个月行角膜内皮显微镜检查,观察角膜内皮细胞密度和形态,并分析切削深度与内皮细胞的相关性。结果A组术前平均角膜内皮细胞密度为(3006.35±345.11)个/mm^2,术后3个月为(3056.75±357.36)个/mm^2,两者比较差异无显著性(P〉0.05)。B组术后平均角膜内皮细胞密度较术前增加(260.7±102.4)个/mm^2,有显著性差异(P〈0.01)。术后角膜内皮细胞形态结构无明显改变。A组角膜切削深度与术后平均角膜内皮细胞密度无显著相关性,(r=0.0267,P〉0.05)。结论LASIK术后早期不引起中央部角膜内皮细胞密度和形态的改变,是一种矫正近视眼安全的角膜屈光手术,但其对角膜内皮细胞的远期影响有待于进一步观察研究。  相似文献   

17.
目的:总结准分子激光角膜原位磨镶术(LASIK)术中出现游离瓣的原因及防治方法。方法:8眼LASIK术中出现的游离瓣,给予逐项分析,并对结果进行随访观察,结果:8眼游离瓣的患者术后第2天裸眼视力(OBCV)≥1.0者3眼,裸眼和≥0.6者5眼,术后3月视力明显提高,1年视力仍稳定,结果:LASIK术中出现游离瓣,只要及时处理,不影响疗效。  相似文献   

18.
复性近视散光角膜地形图的临床分析   总被引:3,自引:1,他引:3  
目的 全面了解复性近视散光患者角膜各区散光改变及对眼球散光的影响。方法 对15 0眼进行角膜地形图测量及视网膜检影检查 ,进行t检验及直线相关分析。结果 复性近视散光患者角膜 3mm区、 5mm区、 7mm区散光轴差异无显著意义 (P >0 0 5 ) ,3mm区与 5mm区散光度差异无显著意义 ,并与眼球散光度呈正相关 :眼球散光度 (D ) =0 64 7D3mm ( 3mm区散光度 ) 0 810D5mm ( 5mm区散光度 ) -0 14 9D7mm ( 7mm区散光度 ) -0 2 3 5。结论 人眼的散光 71 2 %由角膜散光决定 ,而角膜散光值主要由角膜 3mm区、 5mm区散光值决定 ,尤其 5mm区是反映角膜散光最敏感、稳定的区域  相似文献   

19.
目的分析高度近视LASIK与LASEK术后角膜地形图的变化,评价LASEK治疗高度近视的效果。方法选取接受准分子激光高度近视矫正术的连续性病例68例(125眼)。术前等效球镜值为-6.00D~-12.00D,平均(-8.91±2.12)D。按手术方式分为两组:LASEK组和LASIK组。比较术前、术后1个月、3个月和6个月患者角膜地形图的变化。结果两组术前角膜地形冈均以不对称领结型为主,LASEK组为55.6%,LASIK组为54.7%,两组差异无统计学意义(P〉0.05);术后6月,两组均以平滑型为主,LASEK组为79.2%,LASIK组为83.0%,两组均无偏中心切削或中央岛型,两组差异无统计学意义(P〉0.05)。随着时间的推移,两组中的半环型均向平滑型转变。术后1个月、3个月、6个月与术前相比,两组模拟角膜镜度数(simk)的等效值、Simk差值明显减小,角膜不规则指数(CIM)明显增高,角膜形态因子(SF)向负值改变,其差异有统计学意义(P〈0.05)。术后1个月,LASEK组CIM值、Simk差值、SF绝对值均高于LASIK组,两组差异有统计学意义(P〈0.05)。术后3个月和6个月LASEK组CIM值低于LASIK组,两组差异有统计学意义(P〈0.05),而Simk差值、Simk等效值及SF绝对值与LASIK组相比,差异无统计学意义(P〉0.05)。结论LASEK治疗高度、超高度近视术后角膜地形网形态较LASIK平整、规则。远期效果有待进一步观察。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号