1.
Interatrial Conduction During Cardiac Pacing   总被引:2,自引:0,他引:2  
DDD pacemakers sense and pace right-sided cardiac chambers. The relationship of atrial to ventricular systole on the left side of the heart is of importance for systemic hemodynamics. Effective atrioventricular synchrony is partially determined by interatrial conduction time (IACT). At the time of DDD pacemaker implantation, interatrial conduction was measured using an intraesophageal pill electrode in 25 patients who were on no cardiac medications. Mean interatrial conduction time for all patients prolonged from 95 ± 18 ms during sinus rhythm to 122 ± 30 ms during right atrial pacing (p < 0.001). In 16 patients with P wave duration < 110 ms interatrial conduction prolonged from 85 ± 10 ms during sinus rhythm to 111 ± 9 ms during right atrial pacing (p < 0.01) compared to 114 ± 20 ms prolonging to 111 ± 19 ms (p < 0.01] in 9 patients with P wave duration > 110 ms. In each patient, while atrioventricular conduction prolonged with incremental right atrial pacing, interatrial conduction times did not vary. Interatrial conduction prolongs from baseline during atrial pacing and remains constant at all paced rates from 60–160 heats per minute. In addition to longer interatrial conduction times during sinus rhythm, patients with electrocardiographic P wave prolongation have longer interatrial conduction times during right atrial pacing than do normals (p < 0.0001). Based on interatrial conduction times alone, the AV interval during DDD cardiac pacing should be approximately 25 ms longer during AV pacing as compared to atrial tracking.  相似文献   

2.
Using telemetry, right atrial electrogram (RA), and marker channel of atrial sense events (MA) in combination with the left atrial electrogram (LA), recorded by a filtered bipolar esophageal lead, interatrial conduction during submaximal exercise and at rest was examined in 46 DDD pacemaker patients. The RA-LA and MA-LA conduction times measured in the presence of atrial sensing (VDD) as well as the conduction time SA-LA from atrial stimulus (SA) to LA, determined during atrial pacing (DDD) were found to be individual constants independent of exercise induced sympathetic influences. Thus, having determined an optima! mechanical interval (LA-LV)mech/opt from left atrium to ventricle by other methods, the optimal AV delay for DDD as well as for VDD operation can be calculated by the sum of the appropriate interatrial conduction time (SA-LA, respectively MA-LA) and the (LA-LV)mech/opt interval. Due to the constant SA-LA and MA-LA, the difference between these two values (AV delay correction interval) is a constant as well, which remains unchanged during exercise. Therefore, in selecting the rate responsive AV delay, only hemodynamic and not electrophysiologica] measurements need to be considered.  相似文献   

3.
The atrioventricular (AV) interval is critical in dual chamber (DDD) pacing in patients with hypertrophic obstructive cardiomyopathy (HOCM) to obtain full ventricular capture (FVC) with maximal reduction of the left ventricular (LV) outflow gradient and optimal LV diastolic filling. We studied the relationship of FVC, fusion, spontaneous AV conduction, and the QT interval. Methods: 11 patients with various cardiac diseases and stable AV conduction received a QT sensing Diamond (tm) Vitatron, DDD pacemaker. Software was downloaded into the pacemaker. In the DDD pacing mode, with the QT interval measured from the ventricular pacing stimulus to the end of the T wave, the AV interval was shortened from 400 ms, in 20-ms steps, to 90 ms. At 90 ms the stimulation rate was increased by 30 beats/mm and the AV interval was increased stepwise. FVC and fusion was examined on the surface ECG, Results: At 400 ms interval, spontaneous AV conduction inhibited the pacemaker. Shortening the AV interval resulted in pacing with a short QT interval. Further reduction of the AV interval resulted in a longer QT interval up to a point where the QT interval became stable. This point, the bending point in the plot of measured QT interval versus shortened AV intervals, coincided with the point of FVC. The relation of the QT-AV interval plot and the point of fusion was comparable when lengthening the AV interval at a 30 beats/mm faster stimulation rate. Conclusion: The bending point in the QT interval versus AV interval plots showed a good correlation with the FVC and fusion points observed on ECG. The results suggest that automatic discrimination between fusion and full capture using QT interval measurements may be feasible.  相似文献   

4.
The purpose of the study was to compare the effects of DDD pacing with optimal AV delay and AAI pacing on the systolic and diastolic performance at rest in patients with prolonged intrinsic AV conduction (first-degree AV block). We studied 17 patients (8 men, aged 69 +/- 9 years) with dual chamber pacemakers implanted for sick sinus syndrome in 15 patients and paroxysmal high degree AV block in 2 patients. Aortic flow and mitral flow were evaluated using Doppler echocardiography. Study protocol included the determination of the optimal AV delay in the DDD mode and comparison between AAI and DDD with optimal AV delay for pacing rate 70/min and 90/min. Stimulus-R interval during AAI (ARI) was 282 +/- 68 ms for rate 70/min and 330 +/- 98 ms for rate 90/min (P < 0.01). The optimal AV delay was 159 +/- 22 ms. AV delay optimization resulted in an increase of an aortic flow time velocity integral (AFTVI) of 16% +/- 9%. At rate 70/min the patients with ARI < or = 270 ms had higher AFTVI in AAI than in DDD (0.214 +/- 0.05 m vs 0.196 +/- 0.05 m, P < 0.01), while the patients with ARI > 270 ms demonstrated greater AFTVI under DDD compared to AAI (0.192 +/- 0.03 m vs 0.166 +/- 0.02 m, P < 0.01). At rate 90/min AFTVI was higher during DDD than AAI (0.183 +/- 0.03 m vs 0.162 +/- 0.03 m, P < 0.01). Mitral flow time velocity integral (MFTVI) at rate 70/min was higher in DDD than in AAI (0.189 +/- 0.05 m vs 0.173 +/- 0.05 m, P < 0.01), while at rate 90/min the difference was not significant in favor of DDD (0.149 +/- 0.05 m vs 0.158 +/- 0.04 m). The results suggest that in patients with first-degree AV block the relative impact of DDD and AAI pacing modes on the systolic performance depends on the intrinsic AV conduction time and on pacing rate.  相似文献   

5.
Prevalence and significance of ventriculoatrial conduction   总被引:1,自引:0,他引:1  
Because retrograde atrioventricular conduction may predispose to pacemaker-induced tachycardia when DDD pacing is employed, we assessed ventriculo-atrial conduction in 117 patients undergoing electrophysiologic studies. Ventriculo-atrial conduction was present in 40% with a mean (±sem) conduction time of 205 ± 12 ms. The maximum VA conduction time following minimum extrastimulus intervals averaged 258 ± 14 ms. Antegrade AV nodal properties predicted VA conduction in only 67% by using stepwise discriminant analysis. Only the PR interval, AH interval, and AV nodal effective refractory periods were helpful in predicting ventriculo-atrial conduction. Although ventriculo-atrial conduction time increased on most antiarrhythmic drugs, it was infrequently eliminated.  相似文献   

6.
Comparison of Intrinsic Versus Paced Ventricular Function   总被引:3,自引:0,他引:3  
There is increasing evidence supporting the benefits of providing optimum AV delay in cardiac pacing, though controversy exists regarding its value and the benefits of intrinsic versus paced ventricular activation. This study compared various AV delays at rest in patients whose native AV delays were 200 msec. Only patients with DDD pacemakers who had intact AV conduction and normal ventricular activation were included in the study. Nine patients were studied. Methods: Ten studies were performed. Evaluation was done in AAI and DDD modes at paced heart rates of 60/min or as close as possible to the intrinsic heart rate if this was > 60/min. Stroke volume (SV) and cardiac output (COJ were measured. Results: When AV sequential pacing in the DDD mode with an optimum AV delay was compared to AAI pacing with a prolonged AV interval, the average optimum AV delay in the DDD mode was 157 msec and ranged from 125 to 175 msec. The average AV interval in the AAI mode was 245 msec and ranged from 212 to 300 msec. In the DDD mode, there was an overall significant improvement in CO of 11% and SV of 9%. Patients with intrinsic AV conduction times of > 220 msec showed an overall significant improvement in CO of 13% and SV of 11%. In patients with intrinsic AV conduction times of < 220 msec, an improvement in CO of 6% and SV of 4% was seen. Conclusions: (1) An optimum AV delay is an important component of hemodynamic performance; and (2) AV sequential pacing at rest with an optimum AV delay may provide better hemodynamic performance than atrial pacing with intrinsic ventricular conduction when native AV conduction is prolonged > 220 msec.  相似文献   

7.
During atrioventricular (AV) sequential pacing from the right heart, the interval between the left atrium and ventricle may vary from the programmed AV interval depending on the position of the atrial and ventricular electrodes and interatrial and interventricular conduction. The aim of this study was to determine the hemodynamic effects of altering the left AV interval while keeping the programmed AV interval constant. Four male and 17 female patients, aged 49 ± 15 years were studied. The left AV interval was measured by a catheter in the coronary sinus. Stroke volume and mitral flow were measured by simultaneous echo Doppler during AV sequential pacing from the right atrial appendage and right ventricular apex at programmed AV intervals of 100. 60, and 6 ms. The atrial catheter was then positioned on the atrial septum and the measurements repeated. With the atrial catheter in the right atrial appendage, interatrial activation time (118 ± 20 ms) was similar to interventricular activation time (125 ± 21 ms) and the left AV interval was almost identical to the programmed right AV interval. There was a significant correlation between interatrial and interventricular activation times (r = 0.8; P < 0.001). Positioning the atrial electrode on the septum decreased interatrial activation time by 39 ± 12 ms and increased the left AV interval by a similar amount. At a programmed AV interval of 60 ms, the left AV interval increased from 67 ± 15 ms to 105 ± 17 ms after the atrial catheter was repositioned from the appendage to the septum (P < 0.001). Compared to pacing from the right atrial appendage, atrial septal pacing increased mitral A wave velocity integral (2.8 ± 1.4 vs 4.4 ±1.7 cm at a programmed AV interval of 60 ms, P < 0.01), decreased E wave velocity integral (8.1 ± 2.2 vs 6.1 ± 2.4 cm, P < 0.001) but did not alter stroke volume (44.8 ± 10.6 vs 44.9 ± 10.1 mL). In contrast, a 40 ms decrease in the programmed right AV interval from 100 to 60 ms decreased stroke volume from 48.0 ± 10.0 to 44.9 ± 10.2 mL (P < 0.001). There was a strong relationship between interatrial and interventricular conduction so that patients with prolonged interatrial conduction still had equivalent left and right AV intervals during atrioventricular sequential pacing from the right atrial appendage and right ventricular apex. Positioning the atrial electrode on the septum decreases interatrial activation time and increases the left AV interval by about 40 ms but has minimal hemodynamic effect in patients without heart failure.  相似文献   

8.
Cardiac function and electrical stability may be improved by programming of optimal AV delay in DDD pacing. This study tested the hypothesis if the global atrial conduction time at various pacing sites can be derived from the surface ECG to achieve an optimal electromechanical timing of the left heart. Data were obtained from 60 patients following dual chamber pacemaker implantation. Right atrial septal pacing was associated with significantly shorter atrial conduction time (P < 0.0005) and P wave duration (P < 0.005), compared to standard right atrial pacing sites at the right atrial appendage or at the right free wall. The last two pacing sites showed no significant difference. In a group of 31 patients with AV block, optimal AV delay was achieved by programming a delay of 100 ms from the end of the paced P wave to peak/nadir of the paced ventricular complex. Optimization of AV delay resulted in a relative increase of echocardiographic stroke volume (SV) (10.9 +/- 13.7%; 95% CI: 5.9-15.9%) when compared to nominal AV delay (170 ms). Optimized AV delay was highly variable (range 130-250 ms; mean 180 +/- 35 ms). The hemodynamic response was characterized by a weak significant relationship between SV increase and optimized AV delay (R2 = 0.196, R = 0.443, P = 0.047). The study validated that septal pacing is advantageous for atrial synchronization compared to conventional right atrial pacing. Tailoring the AV delay with respect to the surface ECG improved systolic function significantly and was superior to nominal AV delay settings in the majority of patients.  相似文献   

9.
The current method of pacing the right atrium from the appendage or free wall is often the source of delayed intraatrial conduction and discoordinate left and right atrial mechanical function. Simultaneous activation of both atria with pacing techniques involving multisite and multilead systems is associated with suppression of supraventricular tachyarrhythmias and improved hemodynamics. In the present study we tested the hypothesis that pacing from a single site of the atrial septum can synchronize atrial depolarization. Five males and two females (mean age 58 ± 6 years) with drug refractory paroxysmal atrial fibrillation (AF) were studied who were candidates for AV junctional ablation. All patients had broad P waves (118 ± 10 ms) on the surface ECG. Multipolar catheters were inserted and the electrograms from the high right atrium (HRA) and proximal, middle, and distal coronary sinus (CS) were recorded. The atrial septum was paced from multiple sites. The site of atrial septum where the timing between HRA and distal CS (d-CS) was ≤ 10 ms was considered the most suitable for simultaneous atrial activation. An active fixation atrial lead was positioned at this site and a standard lead was placed in the ventricle. The interatrial conduction time during sinus rhythm and AAT pacing and the conduction time from the pacing site to the HRA and d-CS during septal pacing were measured. Atrial septal pacing was successful in all patients at sites superior to the CS os near the fossa ovalis. During septal pacing the P waves were inverted in the inferior leads with shortened duration from 118 ± 10 ms to 93 ± 7 ms (P < 0.001), and the conduction time from the pacing site to the HRA and d-CS was 54.3 ± 6.8 ms and 52.8 ± 2.5 ms, respectively. The interatrial conduction time during AAT pacing was shortened in comparison to sinus rhythm (115 ± 18.9 ms vs 97.8 ± 10.3 ms, P < 0.05). In conclusion, simultaneous activation of both atria in patients with prolonged interatrial conduction time can be accomplished by pacing a single site in the atrial septum using a standard active fixation lead placed under electrophysiological study guidance. Such a pacing system allows proper left AV timing and may prove efficacious in preventing various supraventricular tachyarrhythmias.  相似文献   

10.
DDD and AAI pacemakers are considered physiological, since they preserve atrioventricular (AV) synchrony. Artificial pacing, however, is performed largely from right heart chambers, causing aberrant depolarization pathways. Pacing at the right atrial appendage (RAP) is known to delay left atrial contraction due to interatrial conduction time (IACT), and right ventricular (RV) apical pacing (RVP) delays left ventricular (LV) contraction due to interventricular conduction time (TVCT). These delays may render the left heart AV intervals (LAV) either too short or too Jong, thus affecting LV systolic function. The purpose of this study was to evaluate the actual LAV intervals during conventional, right heart AAI and DDD pacing. Resulting LAV intervals were compared to programmed AV values during all DDD pacing modalities. Ten patients with DDD and six patients with AAI pacemakers were studied. IACT was measured from the atrial spike to the onset of left P wave, as recorded by an esophageal lead. Systolic time intervals were measured using either a carotid pulse tracing or a densitogram (photoplethysmography). LV function was appraised by measuring rate-corrected LV ejection time (LVETc). IVCT was measured indirectly as the lengthening of LV preelection period (PEPJ caused by RV pacing, as compared to normal depolarization pathway. Intrinsic‘ACT and IVCT were considered zero. Right heart AV intervals (RAV) were measured from surface ECG and LAVs were calculated according to the following equations: Sinus Rhythm: LAV = RAV; Atrial Pace 4- Ventricular Sense: LAV= RAV ? IACT; Atrial Sense + Ventricular Pace: LAV = RAV + IVCT; Sequential AV Pace: LAV = RAV ? IACT + IVCT, Results: 1. IACT: mean = 73 msec, range: 35–130; IVCT: mean = 50 msec, range: 44–100. 2. Compared to RAVs, LAVs were either too short or too long (?130 to + 300 msec: P < 0.001 J in RAP 4- RVS and RAS + RVP. Conclusions: 1. LAV differed significantly from RAV during AP + VS and AS + VP. 2. “Physiological” RAV intervals in DDD and AAI may cause nonphysiological LAV, possibly affecting LV function. 3. IACT and IVCT should be accounted for when programming DDD PM to provide physiological LAV.  相似文献   

11.
Atrial Septal Pacing: A Method for Pacing Both Atria Simuhaneously   总被引:2,自引:0,他引:2  
By pacing both atria simultaneously, one could reliably predict and optimize left-sided AV timing without concern for IACT. With synchronous depolarization of the atria, reentrant arrhythmias might be suppressed. We studied four male patients (73 ± 3 years) with paroxysmal atrial fibrillation and symptomatic bradyarrhythmias using TEE and fluoroscopy as guides; a standard active fixation screw-in lead (Medtronic model #4058) was attached to the interatrial septum and a standard tined lead was placed in the ventricle. The generators were Medtronic model 7960. The baseline ECG was compared to the paced ECG and the conduction time were measured to the high right atrium, distal coronary sinus and atrial septum in normal sinus rhytbm, atrial septal pacing, and AAT pacing. On the surface ECG, no acceleration or delay in A V conduction was noted during AAI pacing from the interatrial septum as compared with normal sinus rhythm. The mean interatrial conduction time for all 4 patients was 106 ± 2 ms; the interatrial conduction time measured during AAT pacing utilizing the atrial septal pacing lead was 97 ± 4 ms (P = NS). During atrial septal pacing, the mean conduction time to the high right atrium was 53 ± 2 ms. The mean conduction time to the lateral left atrium during atrial septal pacing, was likewise 53 ± 2 ms. We conclude that it is possible to pace both atria simultaneously from a single site using a standard active fixation lead guided by TEE and fluoroscopy. Such a pacing system allows accurate timing of the left-sided AV delay.  相似文献   

12.
BACKGROUND: Ventricular stimulation with automatic control and back-up pulse warrants maximum safety for the patient and increases device longevity. Fusion phenomenon may hinder evoked response (ER) detection and cause unnecessary back-up stimulation. We evaluated an automatic fusion beat management algorithm and its relationship with atrioventricular (AV) interval programming in a DDD/R pacemaker. METHODS: We analyzed 45 Holter registrations of patients implanted with an Insignia Ultra DR. Fusion beat classification, as performed automatically by the Fusion Management Algorithm, was compared to visual inspection by the analyzing physician. Fusions were classified as loss of capture (LOC), true fusions, or fusions classified as captured beats. Patients were divided into two groups according to AV interval programming: long AV delay (AV(l))(>150 ms) short AV delay (AV(s))(相似文献   

13.
We have used Doppler echocardiography to estimate the stroke volume (SV) in a study of 13 patients equipped with DDD pacemakers. SV was measured both during DDD and VVI pacing after observation times of 1,3,6, and 12 months of DDD pacing. SV was also measured at seven atrioventricular (AV) intervals (75-250 ms) in the search for optimal AV intervals. Mitral flow velocity was investigated to see if DDD pacing resulted in synchronous atrial contraction, and if mitral insufficiency existed at any of the pacing modes. Compared with the VVI mode, DDD pacing resulted in a mean increase in SV of 21 +/- 2% for the four observation periods. Two patients with severe left ventricular failure had no significant increase in SV during DDD vs VVI pacing. In each patient, an optimal AV interval ranging between 100-250 ms for the SV was found. Velocity profiles of mitral flow showed synchronous atrial contraction during DDD pacing, but not during VVI pacing. Mitral insufficiency was not seen in any pacing mode. DDD pacing resulted in a reduction in SV during the first 6 months, and was constant thereafter. Doppler echocardiography can be used repeatedly to evaluate the hemodynamic response of DDD pacing vs VVI pacing, and to find which AV interval gives the highest SV in the individual patient. Our study further shows that the hemodynamic benefit of DDD pacing is present after short-term as well as after long-term DDD pacing.  相似文献   

14.
Electrical pacing of the right heart is known to cause delays in the depolarization of left heart chambers, leading to abnormal left heart AV sequence. Interatrial conduction time, defined as the time from the right atrial pacing pulse or intrinsic P to the onset of left atrial P wave, and P wave sensing delay cause a shorter left heart AV interval during atrial pacing-ventricular sensing and atrial sense-ventricular pace. Interventricular conduction time (the time from the right ventricular pacing pulse to the onset of left ventricular depolarization), lengthens left heart AV interval during atrial sensing-ventricular pacing. These delays may add up or partly cancel out, depending on pacing mode. Thus, an algorithm for DDD pacemakers to optimize left heart AV interval by compensating for the above delays is proposed. This algorithm takes into account pacing and sensing delays to deliver a certain AV sequence to the right heart, aimed at producing a physiological left heart AV interval. The optimization of left heart AV interval is achieved by automatically changing right heart AV interval and pacing mode in accordance with known interatrial and interventricular conduction delays, and P wave sense offset.  相似文献   

15.
PADELETTI, et al. : Atrioventricular Interval Optimization in the Right Atrial Appendage and Interatrial Septum Pacing: A Comparison Between ECHC and Peak Endocardial Acceleration. Interatrial septum pacing (IASP) reduces interatrial conduction time and consequently may interfere with atrioventricular delay (AVD) optimization. We studied 14 patients with an implanted BEST Living system device able to measure peak endocardial acceleration (PEA) signal. The aims of our study were to compare the (1) optimal AVD (OAVD) in right atrial appendage pacing (RAAP) and IASP, and (2) OAVD derived by the PEA signal versus OAVD derived by Echo/Doppler evaluation of the left ventricular filling time (LVFT) and cardiac output (CO). Measurements were performed in DDD VDD modes Eight patients (group A) had RAAP and six patients (group B) had IASP. In group A, OAVD measured by LVFT, CO, and PEA was 185 ± 23 ms , 177 ± 19 ms , and 192 ± 23 ms in DDD and 147 ± 19 ms , 135 ± 27 ms , and 146 ± 20 ms in VDD, respectively. OAVD measured by LVFT, CO, and PEA was significantly longer in DDD mode than in VDD (P < 0.01, P < 0.01, P < 0.001 ). In group B, OAVD measured by LVFT, CO, and PEA was 116 ± 19 ms , 113 ± 10 ms , and 130 ± 30ms in DDD and 106 ± 16 ms , 96 ± 15 ms , and 108 ± 26 ms in VDD, respectively. No statistical differences were observed between DDD and VDD. Significant correlations between OAVDs PEA derived and OAVDs LVFT and CO derived were observed (r = 0.71, r = 0.69, respectively ). When new techniques of atrial stimulation, as IASP, are used an OAVD shorter and similar in VDD and DDD has to be considered. The BEST Living system could provide a valid method to ensure, in every moment, the exact required OAVD to maximize atrial contribution to CO.  相似文献   

16.
Background: Managed Ventricular Pacing (MVP) and Search AV+ (SAV+) are two pacing algorithms designed to reduce ventricular pacing. MVP promotes conduction by operating in AAI/R mode with backup ventricular pacing during atrioventricular block (AVB). SAV+ operates in DDD/R mode with a nominal AV extension of 290 ms during atrial sensing and 320 ms during atrial pacing. The reduction in ventricular pacing was compared with these two algorithms in pacemaker patients.
Methods: The EnRhythm and EnPulse clinical studies assessed the percentage of ventricular pacing (%VP) after 1 month. Each patient's AVB status was assigned using the following hierarchical categories: persistent third-degree AVB (p3AVB), episodic third-degree AVB (e3AVB), second-degree AVB (2AVB), first-degree AVB (1AVB), and no AVB (nAVB). The%VP was tabulated for each AVB status category.
Results: Data were available from 322 patients of whom 129 received DDD(R) pacing with the MVP algorithm activated and 193 patients with DDD(R) pacing and the SAV+ function activated, each for a month period. MVP resulted in a significantly lower median%VP than SAV+ in all AVB categories except for p3AVB: nAVB (0.3 vs 2.9, P < 0.0001), 1AVB (0.9% vs 80.6%, P < 0.0001), 2AVB (37.6 vs 99.3, P< 0.002), e3AVB (1.2 vs 42.2, P = 0.02), p3AVB (98.9 vs 100, P = 1.00).
Conclusion: MVP resulted in a greater reduction in%VP than SAV+ across all patient groups except persistent third-degree AV block. The greatest reduction in%VP was observed in patients with mildly impaired AV conduction.  相似文献   

17.
A New Dual-Chamber Pacing Mode to Minimize Ventricular Pacing   总被引:5,自引:0,他引:5  
Despite the low long-term incidence of high-degree atrioventricular (AV) block and the known negative effects of ventricular pacing, programming of the AAI mode in patients with sinus node dysfunction (SND) remains exceptional. A new pacing mode was, therefore, designed to combine the advantages of AAI with the safety of DDD pacing. AAIsafeR behaves like the AAI mode in absence of AV block. First- and second-degree AV blocks are tolerated up to a predetermined, programmable limit, and conversion to DDD takes place in case of high-degree AV block. From DDD, the device may switch back to AAI, provided AV conduction has returned. The safety of AAIsafeR was examined in 43 recipients (70 ± 12-year old, 24 men) of dual chamber pacemakers implanted for SND or paroxysmal AV block. All patients underwent 24-hour ambulatory electrocardiographic recordings before hospital discharge and at 1 month of follow-up with the AAIsafeR mode activated. No AAIsafeR-related adverse event was observed. At 1 month, the device was functioning in AAIsafeR in 28 patients (65%), and the mean rate of ventricular pacing was 0.2%± 0.4%. Appropriate switches to DDD occurred in 15 patients (35%) for frequent, unexpected AV block. AAIsafeR mode was safe and preserved ventricular function during paroxysmal AV block, while maintaining a very low rate of ventricular pacing. The performance of this new pacing mode in the prevention of atrial fibrillation will be examined in a large, controlled study.  相似文献   

18.
Pacemaker circus movement tachycardia (PCMT) during DDD pacing is usually sustained by retrograde natural and antegrade electronic atrioventricular (AV) conduction. As PCMT is often initiated by a ventricular premature beat (VPB) one method of its prevention is the programming of an atrial stimulus synchronously following a ventricular extrasystole. A patient is described with preserved antegrade, but without retrograde, i.e., VA, conduction. The optional pacemaker mode of synchronous atrial stimulation following a VPB caused an unusual PCMT sustained by retrograde electronic and antegrade natural AV conduction. This PCMT is similar to a natural reentry tachycardia, the most common variety of which (based on retrograde conduction) is termed antidromic and that which we describe is orthodromic.  相似文献   

19.
A 58-year-old man with an implanted minute ventilation rate adaptive DDD pacemaker underwent RF ablation of the AV junction because of symptomatic supraventricular tachyarrhythmias. Immediately after ablation, while the pacemaker was programmed in the DDDR mode, AV sequential pacing at upper rate was observed. After programming the pacing system to the DDD mode and repeated ablation, no abnormalities were observed. It was concluded that AV sequential upper rate pacing was caused by false interpretation of the RF current by the sensor measuring transthoracic impedance as an indicator for minute ventilation.  相似文献   

20.
Temporary atrial pacing (coded AVI pacing) has recently been proposed to assess atrial capture in patients with unipolar dual chamber pacemakers. This pacing mode can usually be achieved by programming the ventricular output to a subthreshold value. In patients with noncommitted bifocal pacemakers, AVI pacing can also be obtained by prolonging the programmed AV delay allowing for spontaneous conduction after atrial capture. However, in patients with prolonged AV conduction and a low aventricular stimulation threshold, ventricular stimulation cannot be prevented using the forementioned procedures. Using chest wall stimulation, we developed and tested a new method of temporary AVI pacing in patients with noncommitted DDD or DVI pacemakers.  相似文献   