首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Objective

The success of removable partial dentures (RPDs) is partly dependent on patients’ acceptance and compliance in using them. The purpose of this study was to describe the usage of removable partial dentures (RPDs) by patients 1 year after insertion and to evaluate the factors that influence their denture usage.

Methods

Forty-seven patients who received 75 new RPDs at the undergraduate clinic of College of Dentistry, King Saud University, were contacted by telephone 1 year later for an interview. The questions covered denture usage, patient’s satisfaction and reasons for non-use.

Results

Results showed that 36% of patients discarded or occasionally used their RPDs. There was no significant association between denture usage and RPD experience, location or Kennedy classification. A significantly more RPD rejection was found when it was opposed by natural teeth or complete denture. The most quoted reason for RPD rejection was pain and discomfort.

Conclusion

Despite the short follow-up period, RPDs were poorly accepted by patients treated by undergraduate students.  相似文献   

2.

Objective

Removable partial dentures (RPD) require different hygiene care, and association of brushing and chemical cleansing is the most recommended to control biofilm formation. However, the effect of cleansers has not been evaluated in RPD metallic components. The aim of this study was to evaluate in vitro the effect of different denture cleansers on the weight and ion release of RPD.

Material and Methods

Five specimens (12x3 mm metallic disc positioned in a 38x18x4 mm mould filled with resin), 7 cleanser agents [Periogard (PE), Cepacol (CE), Corega Tabs (CT), Medical Interporous (MI), Polident (PO), 0.05% sodium hypochlorite (NaOCl), and distilled water (DW) (control)] and 2 cobalt-chromium alloys [DeguDent (DD), and VeraPDI (VPDI)] were used for each experimental situation. One hundred and eighty immersions were performed and the weight was analyzed with a high precision analytic balance. Data were recorded before and after the immersions. The ion release was analyzed using mass spectrometry with inductively coupled plasma. Data were analyzed by two-way ANOVA and Tukey HSD post hoc test at 5% significance level.

Results

Statistical analysis showed that CT and MI had higher values of weight loss with higher change in VPDI alloy compared to DD. The solutions that caused more ion release were NaOCl and MI.

Conclusions

It may be concluded that 0.05% NaOCl and Medical Interporous tablets are not suitable as auxiliary chemical solutions for RPD care.  相似文献   

3.

Objective

This study evaluated the efficacy of NitrAdineTM-based disinfecting cleaning tablets for complete denture, in terms of denture biofilm removal and antimicrobial action.

Material and methods

Forty complete denture wearers (14 men and 26 women) with a mean age of 62.3±9.0 years were randomly assigned to two groups and were instructed to clean their dentures according to two methods: brushing (control) - 3 times a day with denture brush and tap water following meals; brushing and immersion (experimental) - brushing the denture 3 times a day with denture brush and tap water following meals and immersion of the denture in NitrAdineTM-based denture tablets (Medical InterporousTM). Each method was used for 21 days. Denture biofilm was disclosed by a 1% neutral red solution and quantified by means of digital photos taken from the internal surface before and after the use of the product. Microbiological assessment was conducted to quantify Candida sp.

Results

An independent t-test revealed a significant lower biofilm percentage for the experimental group (4.7, 95% CI 2.4 to 7.9) in comparison with the control group (mean 37.5, 95% CI 28.2 to 48.1) (t38=7.996, p<0.001). A significant reduction of yeast colony forming units could be found after treatment with Medical InterporousTM denture tablets as compared to the control group (Mann-Whitney test, Z=1.90; p<0.05).

Conclusion

The present findings suggest that NitrAdineTM-based disinfecting cleaning tablets are efficient in removal of denture biofilm. In addition, a clear antimicrobial action was demonstrated. Therefore, they should be recommended as a routine denture maintenance method for the prevention of the development of microbial biofilm-induced denture stomatitis.  相似文献   

4.

PURPOSE

Study was conducted to determine and assess the effect of different type of denture adhesives on the incisal bite force of complete denture wearers until the dislodgement of upper denture, using pressure transducer.

MATERIALS AND METHODS

30 patients out of 100 were included in the study. Based on the Kapur''s method of scoring denture retention and stability, these patients were divided into 3 groups- Group A - Clinically good dentures; Group B - Clinically fair dentures; and Group C - Clinically poor dentures. A custom made occlusal force meter was constructed based on the load cell type of pressure transducers. Different adhesives (powder, paste and adhesive strips) were used in the study. Complete denture wearers were asked to bite on the load cell and the readings of incisal bite force were recorded. The readings of incisal bite force were subjected to statistical analysis using Repeated measures ANOVA followed by post-hoc bonferroni test.

RESULTS

The result suggests that denture adhesives improved the incisal bite force of complete denture wearers significantly The incisal bite force (in kg) in Group A without using adhesives, with powder adhesive, with paste adhesive and with adhesive strips was found to be 2.48 (± 0.16), 3.43 (± 0.11), 6.01 (± 0.11), 3.22 (± 0.09) respectively. The incisal bite force (in kg) in Group B without using adhesives, with powder adhesive, with paste adhesive and with adhesive strips was found to be 1.87 (± 0.18), 3.35 (± 0.14), 5.34 (± 0.18), 3.21 (± 0.12) respectively. The incisal bite force (in kg) in Group C without using adhesives, with powder adhesive, with paste adhesive and with adhesive strips was found to be 1.00 (± 0.17), 3.07 (± 0.14), 4.37 (± 0.26), 2.99 (± 0.14) respectively.

CONCLUSION

Within the limitations of the study, it was concluded that the use of denture adhesive was found to be significantly effective in improving the incisal bite force of complete dentures until the dislodgement of upper denture. Fittydent paste adhesive was found to be more effective than the powder and strips adhesives. The improvement in incisal bite force was found to be higher in Group C in comparison to that of Group A and Group B.  相似文献   

5.

Background

Fractures of acrylic resin dentures are a common occurrence in clinical dentistry. The denture may be fractured accidentally when dropped or while in service in the mouth due to flexural fatigue.

Objectives

The aim of this study was to compare the elastic modulus and the flexural strength between two heat-cured acrylic resins used in denture bases: a high-impact resin (Lucitone 199) and a traditional resin (Rodex).

Materials and methods

Rectangular strips of Lucitone 199 and Rodex (10 samples each) were fabricated and stored in artificial saliva at 37 °C for 2 weeks. The specimens were subjected to a three-point flexural test. The data were statistically analysed with Student’s t-test (p ⩽ .05).

Results

The high-impact acrylic resin had a lower elastic modulus (p = .000) and higher flexural strength (p = .001) compared to the traditional acrylic resin.

Conclusion

Within the limitations of this study, it can be concluded that the high-impact acrylic resin is a suitable denture base material for patients with clinical fracture of the acrylic denture.  相似文献   

6.

Objective:

The presence of Candida albicans on the surfaces of denture-base acrylic resins is strongly related to the development of oral stomatitis. This study evaluated the antifungal action of different agents over microwave-cured acrylic resin without polishing specimens previously contaminated with Candida albicans.

Material and Methods:

Sixty specimens were immersed in BHI broth previously inoculated with the yeast and stored for 3 h at 37°C. They were divided into 5 experimental groups (n=10): G1: 2% chlorhexidine solution (10 min); G2: 0.5% sodium hypochlorite (10 min); G3: modified sodium hypochlorite (10 min); G4: effervescent agent (5 min); G5: hydrogen peroxide 10v (30 min). The specimens of the control group 1 (C1) were not disinfected. Ten additional specimens of the control group 2 (C2) were not infected with the yeast, aiming to check the asepsis during the experiment. The disinfection agents were neutralized and the acrylic resin specimens were immersed in BHI Broth for 24 h. Culture media turbidity was evaluated spectrophotometrically according to the transmittance degree, i.e. the higher the transmittance the stronger the antimicrobial action. Statistical analysis was performed (Kruskal-Wallis Test, p<0.05).

Results:

The results, represented by the medians, were: G1 = 40; G2 = 100; G3 = 100; G4 = 90; G5 = 100; C1 = 40; C2 = 100.

Conclusions:

This in vitro study suggested that sodium hypochlorite-based substances and hydrogen peroxide are more efficient disinfectants against C. albicans than 2% chlorhexidine solution and the effervescent agent.  相似文献   

7.
Adequate denture hygiene can prevent and treat infection in edentulous patients. They are usually elderly and have difficulty for brushing their teeth.

Objective

This study evaluated the efficacy of complete denture biofilm removal using chemical (alkaline peroxide-effervescent tablets), mechanical (ultrasonic) and combined (association of the effervescent and ultrasonic) methods.

Material and Methods

Eighty complete denture wearers participated in the experiment for 21 days. They were distributed into 4 groups (n=20): (1) Brushing with water (Control); (2) Effervescent tablets (Corega Tabs); (3) Ultrasonic device (Ultrasonic Cleaner, model 2840 D); (4) Association of effervescent tablets and ultrasonic device. All groups brushed their dentures with a specific brush (Bitufo) and water, 3 times a day, before applying their treatments. Denture biofilm was collected at baseline and after 21 days. To quantify the biofilm, the internal surfaces of the maxillary complete dentures were stained and photographed at 45º. The photographs were processed and the areas (total internal surface stained with biofilm) quantified (Image Tool 2.02). The percentage of the biofilm was calculated by the ratio between the biofilm area multiplied by 100 and the total area of the internal surface of the maxillary complete denture.

Results

The Kruskal-Wallis test was used for comparison among groups followed by the Dunn multiple-comparison test. All tests were performed respecting a significance level of 0.05. Significant difference was found among the treatments (KW=21.18; P<0.001), the mean ranks for the treatments and results for Dunn multiple comparison test were: Control (60.9); Chemical (37.2); Mechanical (35.2) and Combined (29.1).

Conclusion

The experimental methods were equally effective regarding the ability to remove biofilm and were superior to the control method (brushing with water). Immersion in alkaline peroxide and ultrasonic vibration can be used as auxiliary agents for cleaning complete dentures.  相似文献   

8.

Objective:

This study evaluated the fracture toughness (FT) of denture base and autopolymerizing reline resins, with and without thermocycling (T).

Material and Methods:

Specimens of each material (denture base acrylic resin - Lucitone 550 - L; autopolymerizing reline resins - Ufi Gel Hard-UH, Tokuyama Rebase II-TR, New Truliner- NT and Kooliner-K), were produced, notched and divided into two groups (n=10): CG (control group of autopolymerizing reline resins and L): FT tests were performed after polymerization; TG (thermocycled group): FT tests were performed after T (5ºC and 55ºC for 5,000 cycles).

Results:

Results (MPa.m(1/2)) were analyzed by two-way ANOVA and Tukey''s test (p=0.05). L exhibited the highest FT mean values in both groups (CG - 2.33; TG - 2.17). For the CG groups, NT showed the highest FT (1.64) among the autopolymerizing reline resins, and K the lowest (1.04). After T, when the autopolymerizing reline resins were compared, a statistically significant difference in FT was found only between the NT (1.46) and TR (1.00).

Conclusions:

Thermocycling increased the FT of K and did not influence the FT of L, UH, TR and NT.  相似文献   

9.

Objective

The shear bond strengths of two hard chairside reline resin materials and an auto-polymerizing denture base resin material to cast Ti and a Co-Cr alloy treated using four conditioning methods were investigated.

Material and Methods

Disk specimens (diameter 10 mm and thickness 2.5 mm) were cast from pure Ti and Co-Cr alloy. The specimens were wet-ground to a final surface finish of 600 grit, air-dried, and treated with the following bonding systems: 1) air-abraded with 50-70-µm grain alumina (CON); 2) 1) + conditioned with a primer, including an acidic phosphonoacetate monomer (MHPA); 3) 1) + conditioned with a primer including a diphosphate monomer (MDP); 4) treated with a tribochemical system. Three resin materials were applied to each metal specimen. Shear bond strengths were determined before and after 10,000 thermocycles.

Results

The strengths decreased after thermocycling for all combinations. Among the resin materials assessed, the denture base material showed significantly (p<0.05) greater shear bond strengths than the two reline materials, except for the CON condition. After 10,000 thermocycles, the bond strengths of two reline materials decreased to less than 10 MPa for both metals. The bond strengths of the denture base material with MDP were sufficient: 34.56 MPa for cast Ti and 38.30 for Co-Cr alloy.

Conclusion

Bonding of reline resin materials to metals assessed was clinically insufficient, regardless of metal type, surface treatment, and resin composition. For the relining of metal denture frameworks, a denture base material should be used.  相似文献   

10.

Objective

The objective of this study was to compare the antimicrobial effect of mouthwashes containing Calendula officinalis L., Camellia sinensis (L.) Kuntze and 0.12% chlorhexidine digluconate on the adherence of microorganisms to suture materials after extraction of unerupted third molars.

Material and Methods

Eighteen patients with unerupted maxillary third molars indicated for extraction were selected (n=6 per mouthwash). First, the patients were subjected to extraction of the left tooth and instructed not to use any type of antiseptic solution at the site of surgery (control group). After 15 days, the right tooth was extracted and the patients were instructed to use the Calendula officinalis, Camellia sinensis or chlorhexidine mouthwash during 1 week (experimental group). For each surgery, the sutures were removed on postoperative day 7 and placed in sterile phosphate-buffered saline. Next, serial dilutions were prepared and seeded onto different culture media for the growth of the following microorganisms: blood agar for total microorganism growth; Mitis Salivarius bacitracin sucrose agar for mutans group streptococci; mannitol agar for Staphylococcus spp.; MacConkey agar for enterobacteria and Pseudomonas spp., and Sabouraud dextrose agar containing chloramphenicol for Candida spp. The plates were incubated during 24-48 h at 37ºC for microorganism count (CFU/mL).

Results

The three mouthwashes tested reduced the number of microorganisms adhered to the sutures compared to the control group. However, significant differences between the control and experimental groups were only observed for the mouthwash containing 0.12% chlorhexidine digluconate.

Conclusions

Calendula officinalis L. and Camellia sinensis (L.) Kuntze presented antimicrobial activity against the adherence of microorganisms to sutures but were not as efficient as chlorhexidine digluconate.  相似文献   

11.

PURPOSE

The midline fracture of maxillary complete dentures is a frequently encountered complication. The purpose of this study was to assess the effect of frenulum height on midline strains of maxillary complete dentures.

MATERIALS AND METHODS

A removable maxillary complete denture was fabricated and duplicated seven times. Four different labial frenulum heights were tested for stresses occurring on the palatal cameo surface. The strains were measured with strain gauges placed on 5 different locations and the stresses were calculated. To mimic occlusal forces bilaterally 100 N of load was applied from the premolar and molar region.

RESULTS

A statistically significant association between the height of the labial frenulum and the calculated stresses and strains was shown (P<.05) predominantly on the midline and especially on the incisive papilla. The results showed that stress on the anterior midline of the maxillary complete denture increases with a higher labial frenulum.

CONCLUSION

Within the limitations of this in vitro study, it can be concluded that the stress on the anterior midline of the maxillary complete denture increases with a higher labial frenulum. Surgical or mechanical precautions should be taken to prevent short-term failure of maxillary complete dentures due to stress concentration and low cycle fatigue tendency at the labial frenulum region.  相似文献   

12.

Objective

This study investigated the effects of different surface treatments on the tensile bond strength of an autopolymerizing silicone denture liner to a denture base material after thermocycling.

Material and Methods

Fifty rectangular heat-polymerized acrylic resin (QC-20) specimens consisting of a set of 2 acrylic blocks were used in the tensile test. Specimens were divided into 5 test groups (n=10) according to the bonding surface treatment as follows: Group A, adhesive treatment (Ufi Gel P adhesive) (control); Group S, sandblasting using 50-µm Al2O3; Group SCSIL, silica coating using 30-µm Al2O3 modified by silica and silanized with silane agent (CoJet System); Group SCA, silica coating and adhesive application; Group SCSILA, silica coating, silane and adhesive treatment. The 2 PMMA blocks were placed into molds and the soft lining materials (Ufi Gel P) were packed into the space and polymerized. All specimens were thermocycled (5,000 cycles) before the tensile test. Bond strength data were analyzed using 1-way ANOVA and Duncan tests. Fracture surfaces were observed by scanning electron microscopy. X-ray photoelectron spectrometer (XPS) and Fourier Transform Infrared spectrometer (FTIR) analysis were used for the chemical analysis and a profilometer was used for the roughness of the sample surfaces.

Results

The highest bond strength test value was observed for Group A (1.35±0.13); the lowest value was for Group S (0.28±0.07) and Group SCSIL (0.34±0.03). Mixed and cohesive type failures were seen in Group A, SCA and SCSILA. Group S and SCSIL showed the least silicone integrations and the roughest surfaces.

Conclusion

Sandblasting, silica coating and silane surface treatments of the denture base resin did not increase the bond strength of the silicone based soft liner. However, in this study, the chemical analysis and surface profilometer provided interesting insights about the bonding mechanism between the denture base resin and silicone soft liner.  相似文献   

13.
In order to prolong the clinical longevity of resilient denture relining materials and reduce plaque accumulation, incorporation of antimicrobial agents into these materials has been proposed. However, this addition may affect their properties.

Objective

This study evaluated the effect of the addition of antimicrobial agents into one soft liner (Soft Confort, Dencril) on its peel bond strength to one denture base (QC 20, Dentsply).

Material and Methods

Acrylic specimens (n=9) were made (75x10x3 mm) and stored in distilled water at 37ºC for 48 h. The drug powder concentrations (nystatin 500,000U - G2; nystatin 1,000,000U - G3; miconazole 125 mg - G4; miconazole 250 mg - G5; ketoconazole 100 mg - G6; ketoconazole 200 mg - G7; chlorhexidine diacetate 5% - G8; and 10% chlorhexidine diacetate - G9) were blended with the soft liner powder before the addition of the soft liner liquid. A group (G1) without any drug incorporation was used as control. Specimens (n=9) (75x10x6 mm) were plasticized according to the manufacturers'' instructions and stored in distilled water at 37ºC for 24 h. Relined specimens were then submitted to a 180-degree peel test at a crosshead speed of 10 mm/min. Data (MPa) were analyzed by analysis of variance (α=0.05) and the failure modes were visually classified.

Results

No significant difference was found among experimental groups (p=0.148). Cohesive failure located within the resilient material was predominantly observed in all tested groups.

Conclusions

Peel bond strength between the denture base and the modified soft liner was not affected by the addition of antimicrobial agents.  相似文献   

14.
Streptococcus mutans is the main etiological agent for dental caries. Recently, photodynamic therapy (PDT) has been introduced as a new modality in bacterial decontamination.

Objective

This in vitro study was carried out to evaluate the susceptibility of Streptococcus mutans to antibacterial PDT using two different photosensitizers and light sources.

Material and Methods

Standard suspensions of S. mutans were exposed to laser light at 662 nm and Radachlorin® or LED 630 nm in combination with Toluidine blue O (TBO). Radiation-only groups, photosensitizer alone, and groups with no treatment were used as controls. Bacterial suspension from each treatment was subcultured onto the surface of Mueller-Hinton agar plates and bacterial growth was assessed. The results were analyzed by analysis of variance and Tukey test (p<0.05).

Results

PDT with TBO and Radachlorin® significantly reduced S. mutans viability, whereas no difference was observed between two groups of PDT. In the groups treated just with the photosensitizer or irradiated alone, no significant reduction of S. mutans colonies was observed.

Conclusion

S. mutans colonies were susceptible to either 662 nm laser or LED light in the presence of Radachlorin® and TBO respectively with no priority.  相似文献   

15.

Introduction:

Most denture base acrylic resins have polymethylmethacrylate in their composition. Several authors have discussed the polymerization process involved in converting monomer into polymer because adequate polymerization is a crucial factor in optimizing the physical properties and biocompatibility of denture base acrylic resins. To ensure the safety of these materials, in vitro cytotoxicity assays have been developed as preliminary screening tests to evaluate material biocompatibility. 3H-thymidine incorporation test, which measures the number of cells synthesizing DNA, is one of the biological assays suggested for cytotoxicity testing. Aim: The purpose of this study was to investigate, using 3H-thymidine incorporation test, the effect of microwave and water-bath post-polymerization heat treatments on the cytotoxicity of two denture base acrylic resins.

Materials and Methods:

Nine disc-shaped specimens (10 x 1 mm) of each denture base resin (Lucitone 550 and QC 20) were prepared according to the manufacturers'' recommendations and stored in distilled water at 37°C for 48 h. The specimens were assigned to 3 groups: 1) post-polymerization in a microwave oven for 3 min at 500 W; 2) post-polymerization in water-bath at 55° C for 60 min; and 3) without post-polymerization. For preparation of eluates, 3 discs were placed into a sterile glass vial with 9 mL of Eagle''s medium and incubated at 37°C for 24 h. The cytotoxic effect of the eluates was evaluated by 3H-thymidine incorporation.

Results:

The results showed that the components leached from the resins were cytotoxic to L929 cells, except for the specimens heat treated in water bath (p<0.05). Compared to the group with no heat treatment, water-bath decreased the cytotoxicity of the denture base acrylic resins.

Conclusion:

The in vitro cytotoxicity of the tested denture base materials was not influenced by microwave post-polymerization heat treatment.  相似文献   

16.

Objective

The aim of this study was to assess the microbial changes in children with fixed orthodontic appliances compared with a control group of children without orthodontic treatment.

Material and Methods

Ninety-five children, aged between 12 and 16 years, participated in this study. Forty-eight subjects were fitted with fixed orthodontic appliances and forty-seven were free of any such appliances. The follow-up was 6 months for all children. The association between orthodontic appliances and high levels of Streptococcus mutans and Lactobacillus spp was assessed with logistic regression models, taking age, sex, pH and buffer capacity into account.

Results

Differences at baseline between the two groups were not statistically significant. We found that wearing a fixed orthodontic appliance was associated with high levels of Streptococcus mutans and Lactobacillus spp (adjusted OR: 6.65, 95% CI [1.98-22.37]; 9.49, 95% CI [2.57-35.07], respectively), independently of other variables.

Conclusion

The originality of the present epidemiological study was to evaluate the evolution of salivary microbial parameters in a population of children with fixed orthodontic appliances. Our results show an increase of Streptococcus mutans and Lactobacillus spp values during the follow-up. The whole dental workforce should be aware that preventive measures are of paramount importance during orthodontic treatment.  相似文献   

17.

Purpose

The purpose of this in vitro study was to compare the stability of removable implant-supported maxillary overdentures with fixed complete dentures and conventional dentures.

Methods

Four types of complete dentures were tested: conventional complete dentures; overdentures retained by a male resilient attachment system; overdentures retained by a combination of clip bar and attachment system; and fixed complete dentures. Each group was placed in the posterior and anterior region and the stability was recorded by measuring the vertical displacement of the prosthesis.

Results

There was a difference in the vertical movement of the prosthesis according to the type of system. The results showed that the behavior of the overdenture retained by a combination of a clip bar and attachment system is comparable with the stabilization of an implant-retained fixed complete denture.

Conclusions

Overdentures retained by a combination of a clip bar and attachment presented better stability and retention capacity under our experimental conditions, close to that of the positive control (fixed complete denture), with the advantages of removable overdentures.  相似文献   

18.

PURPOSE

This study characterized the synthesis of a modified PMMA (Polymethyl methacrylate) denture acrylic loading platinum nanoparticles (PtN) and assessed its bacterial inhibitory efficacy to produce novel antimicrobial denture base material.

MATERIALS AND METHODS

Polymerized PMMA denture acrylic disc (20 mm × 2 mm) specimens containing 0 (control), 10, 50, 100 and 200 mg/L of PtN were fabricated respectively. The obtained platinum-PMMA nanocomposite (PtNC) was characterized by TEM (transmission electron microscopy), SEM/EDX (scanning electron microscope/energy dispersive X-ray spectroscopy), thermogravimetric and atomic absorption spectrophotometer analysis. In antimicrobial assay, specimens were placed on the cell culture plate, and 100 µL of microbial suspensions of S. mutans (Streptococcus mutans) and S. sobrinus (Streptococcus sobrinus) were inoculated then incubated at 37℃ for 24 hours. The bacterial attachment was tested by FACS (fluorescence-activated cell sorting) analysis after staining with fluorescent probe.

RESULTS

PtN were successfully loaded and uniformly immobilized into PMMA denture acrylic with a proper thermal stability and similar surface morphology as compared to control. PtNC expressed significant bacterial anti-adherent effect rather than bactericidal effect above 50 mg/L PtN loaded when compared to pristine PMMA (P=.01) with no or extremely small amounts of Pt ion eluted.

CONCLUSION

This is the first report on the synthesis and its antibacterial activity of Pt-PMMA nanocomposite. PMMA denture acrylic loading PtN could be a possible intrinsic antimicrobial denture material with proper mechanical characteristics, meeting those specified for denture bases. For clinical application, future studies including biocompatibility, color stability and warranting the long-term effect were still required.  相似文献   

19.
Dental caries is still a major oral health problem in most industrialized countries. The development of dental caries primarily involves Lactobacilli spp. and Streptococcus mutans. Although antibacterial ingredients are used against oral bacteria to reduce dental caries, some reports that show partial antibacterial ingredients could result in side effects.

Objectives

The main objective is to test the antibacterial effect of water-soluble chitosan while the evaluation of the mouthwash appears as a secondary aim.

Material and Methods

The chitosan was obtained from the Application Chemistry Company (Taiwan). The authors investigated the antibacterial effects of water-soluble chitosan against oral bacteria at different temperatures (25-37ºC) and pH values (pH 5-8), and evaluated the antibacterial activities of a self-made water-soluble chitosan-containing mouthwash by in vitro and in vivo experiments, and analyzed the acute toxicity of the mouthwashes. The acute toxicity was analyzed with the pollen tube growth (PTG) test. The growth inhibition values against the logarithmic scale of the test concentrations produced a concentrationresponse curve. The IC50 value was calculated by interpolation from the data.

Results

The effect of the pH variation (5-8) on the antibacterial activity of water-soluble chitosan against tested oral bacteria was not significant. The maximal antibacterial activity of water-soluble chitosan occurred at 37ºC. The minimum bactericidal concentration (MBC) of water-soluble chitosan on Streptococcus mutans and Lactobacilli brevis were 400 µg/mL and 500 µg/mL, respectively. Only 5 s of contact between water-soluble chitosan and oral bacteria attained at least 99.60% antibacterial activity at a concentration of 500 µg/mL. The water-soluble chitosan-containin g mouthwash significantly demonstrated antibacterial activity that was similar to that of commercial mouthwashes (>99.91%) in both in vitro and in vivo experiments. In addition, the alcohol-free mouthwash exhibited no cytotoxicity and no oral stinging. To the best of our knowledge, this was the first study to combine in vitro and in vivo investigations to analyze the antibacterial properties of water-soluble chitosan-containing mouthwash.

Conclusions

This study illustrated that water-soluble chitosan may be a viable alternative to commercial mouthwashes in the future.  相似文献   

20.

Objective

The purpose of this study was to determine whether there is a correlation between the clinical quality of conventional complete dentures and patient quality of life.

Materials and methods

This study included a random sample of 32 completely edentulous patients (15 males and 17 females) who were treated with conventional complete dentures. Using a validated questionnaire, three investigators evaluated the dentures independently on the basis of seven clinical parameters: esthetics (lip support and lower lip line), retention and stability of the maxillary and the mandibular dentures, and occlusion. Patients completed the validated Oral Health Impact Profile-20 (OHIP-20) questionnaire. Correlations were determined by using the point-biserial correlation coefficient.

Results

Clinicians rated the overall clinical quality of the dentures satisfactory in 80.3% of patients. The mean (±standard deviation) total OHIP-20 score was 56.3 ± 15.9 out of a possible 120 maximum. A statistically significant negative correlation was found between the stability of the maxillary and mandibular dentures and the total OHIP-20 score (p = 0.009 and 0.0023, respectively). A negative correlation between the total OHIP-20 score and the retention of the mandibular denture approached significance (p = 0.092). Esthetics, retention of the maxillary denture, and occlusion were not correlated with patient quality of life (p > 0.169).

Conclusion

Stability of the maxillary and mandibular dentures is the denture quality parameter that can most significantly affect patient quality of life.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号