首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A 7-year experience with home parenteral nutrition (HPN) in 35 children and adolescents suffering from severe gastrointestinal diseases is reported. The average duration of HPN was 577 days with a mean of 2.9 catheters per patients. There was a total of 82 episodes of proven catheter-related sepsis, an average of 1.5 septic episodes per patient year. In about half of these instances, the catheter had to be removed. Coagulase-negative and -positive staphylococci were the most common organisms isolated. All four Candida infections led to removal of the catheter. Children requiring HPN from early infancy had a higher frequency of catheter-related infections than those started on HPN after the first year of life. In four cases, clinically significant thrombotic complications occurred. The results suggest that even under optimal conditions of catheter placement and with extensive education in aseptic catheter handling, infection is still relatively common in children receiving HPN. However, there was no mortality related to this complication.  相似文献   

2.
Tunnelled silicone rubber right atrial catheters are commonly used to administer long-term total parenteral nutrition (TPN), cancer chemotherapeutic agents, and antimicrobial agents. The indwelling devices potentiate platelet-fibrin thrombi formation, providing a nidus for infection. Although many episodes of sepsis associated with thrombotic tunnelled catheters respond to antimicrobial therapy alone, a significant number require catheter removal. Evidence from case studies and small clinical trials suggests that fibrinolytic agents may increase the response rate and prevent removal of the device when combined with antimicrobial therapy. We present the first case reported of bacterial sepsis secondary to a thrombotic indwelling Hickman catheter for long-term TPN successfully treated with a combination of streptokinase and antibiotic therapies.  相似文献   

3.
One hundred and forty silicone catheters were inserted in 127 patients for long-term intravenous access with a cumulative follow-up time of 21,125 catheter-days (58 patient-years). Fifty-six patients had acquired immunodeficiency syndrome (AIDS); 44 were not AIDS patients and were receiving ambulatory home parenteral nutrition, whereas the remaining 27 did not have AIDS and were receiving home antibiotic therapy. Patients had a mean of 1.1 catheters inserted, and the rate of Hickman catheter-related sepsis was 0.18 per 100 catheter days or 0.6 septic episodes per patient year of treatment. Catheter-related sepsis was higher in AIDS patients (p < .01) and in patients receiving parenteral nutrition (p < .05) compared with those receiving antibiotic therapy. Prior catheter infection and AIDS were the most significant predictors of catheter infection (p < .01). Staphylococcus aureus was the most commonly isolated pathogen (61%) in AIDS patients. Fever (p < .001) and relative leukocytosis (p < .02) were the most common signs of infection. Only 14 infected catheters (37.8%) were salvaged by antibiotic therapy after the initial infection episode, and 6 of these catheters (42.9%) had recurrent multiple infections. In addition, inflammatory bowel disease was found to be a risk factor for venous thrombosis (p = .018). We conclude that because immunocompromised patients have a high risk of infection, catheter-related sepsis in these patients should be treated by catheter removal and antibiotics.  相似文献   

4.
From April 1976 to January 1988, 58 patients received home parenteral nutrition for 2-138 months, median 36 months, corresponding to a total treatment period of 233 patient years. Before 1980 and after 1985, 0.5-2% iodine tincture or 0.5% chlorhexidine in 70% ethyl alcohol were used to disinfect the exit site of the catheter and the connections of the infusion line. In these periods the sepsis incidence was 0.25-0.28 per catheter year, corresponding to one episode of sepsis per 3.6-4.0 catheter years. In the period 1980 to 1985, 10% povidone-iodine (Isobetadine((R))) was used, and the incidence in this period was 0.58, corresponding to one episode of sepsis per 1.7 catheter year. This suggests that 10% povidone-iodine may be inferior to iodine-tincture and chlorhexidine alcohol in this type of catheter care. The incidence of catheter sepsis was 0.32 per catheter year when the catheter was placed on the chest and 0.86 per catheter year with the catheter on the thigh. Klebsiella pneumoniae was the most common microorganism grown when the catheter was placed on the thigh, while coagulase-negative staphylococci were most common when the catheter was placed on the chest.  相似文献   

5.
The objective of this review is to summarize the literature and to look at epidemiology, prevention and treatment of catheter-associated venous thrombosis in home parenteral nutrition patients. The rate of this complication is between 0.01 to 0.03 episodes per catheter year. Several risk factors have been identified, such as the position of the catheter tip, the type of material used and a history of catheter-associated infections. Systematic anticoagulant prophylaxis has largely been ineffective. Good insertion technique and catheter cares remain important preventives measures. Moreover, the optimal anticoagulant treatment is unclear due to lack of well-designed studies. In case of catheter-associated venous thrombosis in home parenteral nutrition patients, removal of the catheter is not mandatory. If it is functional, necessary and without associated infection, long-term systemic anticoagulation will be indicated.  相似文献   

6.
Between 1986 and 1989 we encountered 33 episodes of candida sepsis among 1169 patients receiving TPN for a total of 23350 days (2.8% candida infection rate). Total hospital stay averaged 78 (range 10-230) days and patients received TPN for an average of 21.5 (range 3-83) days before developing candida sepsis. Candida sepsis developed in 8 patients (26.6%) hospitalised in an ICU; 6 patients (20%) receiving high doses of glucocorticoids, 5 patients (16.6%) treated by cytotoxic agents; 23 patients (76.6%) received various combinations of broad-spectrum antibiotics. The number of tubes going in or out numbered an average of 3.6/patient (peripheral and/or central I.V.; endotracheal; tracheostomy; urinary catheter; arterial line; abdominal or chest drains). 18 patients underwent 38 (2.1/patient) operative procedures. 20 patients (66%) suffered fron mono- or polymicrobial bacterial sepsis in addition to candida sepsis, 16 of them metachronously. Candida species isolated were C. albicans - 14 patients; C. tropicalis - 6 patients; C. parapsylosis - 6 patients; not specified - 4 patients. In addition to positive blood cultures we found positive candida cultures in urine, peritoneal cavity, chest cavity, wounds, respiratory tract, intravascular catheters, often in more than one site per patient. All patients were treated with Amphotericin at an average dose of 770 mg/patient. Mortality rate in patients with candida sepsis was 33%. TPN associated candida sepsis seems to be an endogenous self-infecting process in a select group of severely injured-infected-depleted-immunosuppressed patients and is thus completely different from the usual exogenous bacterial TPN associated sepsis. The major risk factors for fungaemia and candida sepsis are the combination of severe underlying disease state, multiple surgical interventions and intravascular lines, the use of broad spectrum antibiotics, TPN, injury and malnutrition associated immunosuppression, multiple tubes and catheters, and intra-abdominal or intra-thoracic infection.  相似文献   

7.
The recent introduction of triple lumen catheters has facilitated the care of seriously ill patients by providing multipurpose central venous access through a single percutaneous 7 French catheter. This prospective study was performed to examine the complications associated with the use of these catheters in patients receiving long-term total parenteral nutrition (TPN). Seventy-five patients undergoing catheterization were randomly separated into two groups: 36 patients underwent placement of a single lumen catheter (SLC), and 39 patients, a triple lumen catheter (TLC). The two groups were comparable with respect to concomitant infections, treatment with antibiotics, and need for intensive care. Patients in the SLC group received TPN for a mean of 9.7 days and in the TLC group, for a mean of 8.5 days (p = 0.427). However, after 5 days of catheterization, there was a marked increase in the number of TLC removed because of skin entry site infections. SLC were more likely to be used for the full duration of TPN administration (p = 0.025). Catheter tips were cultured by semiquantitative techniques. A higher incidence of catheter sepsis was seen with TLC, 12.8% vs 0% with SLC (p = 0.055). TLC used for TPN are associated with higher rates of catheter entry site infections and systemic sepsis. SLC should be used for TPN administration.  相似文献   

8.
All tunnelled central venous catheters (TCVC) placed at the Alberta Children's Hospital in Calgary, Alberta, between November 1984 and July 1987, were retrospectively reviewed to study the association of catheter infection with a number of factors including age, diagnosis, catheter use, and areas caring for children. One hundred children received 130 silastic catheters placed for a total of 17,861 days. Each catheter survived a median of 100 days. Thirty-one episodes of catheter sepsis were identified (one episode for each 576 days of catheter use). Children under 2 years of age had more than two times the risk of catheter infection (p less than 0.01). Children with malabsorption had a greater risk (45.7%) than did those with infection (25.0%) or cancer (15.5%). The use of catheters for total parenteral nutrition (TPN) or for multiple purposes markedly increased the risk of catheter infection. The risk of infection of TCVC appears to be great in the young child, in particular, in those requiring TPN or multiple intravenous infusions. Use of TCVC in these children should be avoided if possible.  相似文献   

9.
BACKGROUND: The antibiotic-lock technique has been suggested to treat catheter-related sepsis in parenteral nutrition and to avoid catheter removal. METHODS: To determine the incidence of catheter-related sepsis, the bacteria involved, and the efficacy of the antibiotic-lock technique with teicoplanin, all patients (n = 263) undergoing parenteral nutrition from January 1997 to December 1999 in one center, with patients at the hospital (n = 209) and at home (54) were retrospectively studied. The antibiotic-lock technique with teicoplanin was systematically used in all suspected infections and maintained in staphylococcus epidermidis (SE) infections. RESULTS: A total of 21 of 263 patients had 34 infections (0.11/patient per year): 12 of 209 hospitalized and 9 of 54 home patients. A total of 10 of 34 infections were due to non-SE, and the catheter was immediately removed. The other 24 of 34 infections were due to SE; in 5 of 24, the catheter was removed after 48 hours of the antibiotic-lock technique because of persistent fever or thrombosis. A total of 5 of 12 patients had 2 or more infections on the same catheter. The antibiotic-lock technique prevented short-term catheter removal in these cases, but a second infection occurred within a median of 50 days. In 4 of 5 cases, a third infection occurred in a mean delay of 90 days so that the catheter was removed. In 3 of 5 patients, bacteria was analyzed with pulsed field gel electrophoresis, which showed that recurrent infections were due to the same strain in all cases. CONCLUSIONS: In this study, the incidence of catheter-related sepsis was low and mostly related to SE. Our results do not support the use of the teicoplanin antibiotic-lock technique in SE infections.  相似文献   

10.
Catheter-related sepsis is one of the most frequent and troublesome complications of parenteral nutrition. In a 2-year survey of 19 home parenteral nutrition patients, with a total of 25.2 years of cyclic nocturnal parenteral nutrition, the annual incidence of catheter-related sepsis was 1.27, of which 84% were due to bacterial catheter infection without any cutaneous focus. These 27 episodes were treated by a daily, 2 ml injection of antibiotic-saline solution, mainly amikacin, locked for 12 h per day within the infected catheter for 15 (7-20) days. On admission the parenteral nutrition was halted for 2 days and the catheter hub was changed. In 7 cases, an average of 3 days (2-5) of systemic antibiotic therapy was given in addition to the 2-week antibiotic-lock. Control of catheter-sepsis was achieved in 93% of the 27 episodes and parenteral nutrition was resumed using the same catheter with only one episode of recurrent sepsis. The present data confirm our preliminary report of the efficacy of the antibiotic-lock technique for the control of bacterial catheter-related sepsis. This treatment offers the advantage over current therapies of avoiding repeated catheter change and 2-6 weeks of systemic antibiotic therapy.  相似文献   

11.
The literature shows that repeated courses of antibiotics and catheter removals in a subset of patients suffering from multiple catheter-related bloodstream infections (CRBSI), are unlikely to prevent recurrence. In acceding to preventative strategies, we report our application of the antimicrobial chemotherapeutic Taurolidine used as a daily flush solution in seven home TPN patients suffering from multiple episodes. A pretreatment infection rate of 10.8 infections per 1000 catheter days decreased to 0.8 after treatment.  相似文献   

12.
A cutaneous infection exposed the cuff of a Broviac catheter employed for home-TPN in a 3-month-old child with ultra-short bowel syndrome. In order to avoid removal of the catheter, sepsis was abated by antibiotic administration through its lumen, then the exposed cuff was covered and fixed by a skin flap. The advantages proceeding from this sort of "emergency rescue" of the Broviac catheter have been: (1) to avoid a new cutdown in a child already submitted to several attempts of cannulation with sacrifice of major vessels; (2) to resume home total parenteral nutrition (TPN) in a short time, being the patient strictly dependent upon his parenteral intake and to spare a well-functioning catheter. Ten months after the last cuff covering by skin flap, the catheter is safely fixed in place and currently employed for home TPN.  相似文献   

13.
AIM: The purpose of this study was to report our compared experience of long-term complications with polyurethane (LeaderCuff) and silicone (Lifevac) tunnelled, cuffed catheters in home adult TPN patients. METHODS: All catheters were inserted by a percutaneous technique under local anaesthesia. RESULTS: Forty silicone catheters were inserted in 31 patients and 13 polyurethane catheters were inserted in 11 patients totaling a total experience of 480 months and 175 months respectively. Mean catheter life span was 12 months (range: 0.25-47) and 13 months (range: 3-44) for Lifevac and LeaderCuff catheters, respectively. Complication rates (expressed as patient-year of TPN) were no significantly different for Lifevac and LeaderCuff catheters: sepsis (0.15 vs 0.14), obstruction (0.05 vs 0), dislodgement (0.13 vs 0.07) and thrombosis (0 vs 0.14). The fracture rate was 20 times lower for Lifevac than for LeaderCuff (P < 0.01): in all cases, this mechanical problem was due to the dysfunction of the detachable flow-control device. CONCLUSION: Both Lifevac and LeaderCuff catheters enable safe, long-term, venous access and prevent, in most cases, inadvertent catheter dislodgement. There is little evidence, from our study, to support the hypothesis that polyurethane catheters offer more security than silicone catheters in home TPN adult patients.  相似文献   

14.
Clinical experience with the multiple lumen central venous catheter   总被引:1,自引:0,他引:1  
One hundred four multiple lumen central venous catheters (MLC) were evaluated in 74 seriously ill patients. Eighty percent of the catheters were placed in an intensive care unit. Each MLC served as access for a mean of 4.5 different functions, including infusions, central venous monitoring and phlebotomy. Complications occurred with 16 MLC (15.4%), including two aberrant placements, 10 mechanical problems, and four septic catheters (3.8%). Simultaneous administration of TPN and other infusions through MLC did not affect the rate of catheter sepsis. MLC are well tolerated and cost effective. They increase the comfort of patients who require complex venous access or who lack peripheral veins. They allow safe concurrent administration of TPN, medications, and central venous monitoring.  相似文献   

15.
The use of continuous, low-dose heparin in total parenteral nutrition (TPN) formulas to limit central venous thrombosis was retrospectively evaluated. Seven of 129 patients (5.4%) developed central vein thrombosis when TPN solutions provided less than 6,000 units (usually 1,000 units/liter) heparin per day. In the subsequent period when heparin was increased to 6,000 units per day, 10 of 858 (less than 1.2%) patients developed a TPN-related thrombosis (P less than 0.0005). The incidence of antithrombin III (AT III) deficiency in a subset of high-risk patients scheduled to receive TPN was 51% (23 of 55). Twelve of the 23 had clinical evidence of thrombosis, whereas only 3 of 22 patients with normal AT III levels did (P less than 0.01) A major contributing factor to the development of thrombosis in TPN appears to be depression in antithrombin III levels, which is commonly found in patients who require this therapy. Low-dose heparin appears to reduce the incidence of thrombosis with TPN when provided continuously in sufficient amounts.  相似文献   

16.
The use of continuous, low-dose heparin in total parenteral nutrition (TPN) formulas to limit central venous thrombosis was retrospectively evaluated. Seven of 129 patients (5.4%) developed central vein thrombosis when TPN solutions provided less than 6,000 units (usually 1,000 units/liter) heparin per day. In the subsequent period when heparin was increased to 6,000 units per day, 10 of 858 (less than 1.2%) patients developed a TPN-related thrombosis (P less than 0.0005). The incidence of antithrombin III (AT III) deficiency in a subset of high-risk patients scheduled to receive TPN was 51% (23 of 55). Twelve of the 23 had clinical evidence of thrombosis, whereas only 3 of 22 patients with normal AT III levels did (P less than 0.01) A major contributing factor to the development of thrombosis in TPN appears to be depression in antithrombin III levels, which is commonly found in patients who require this therapy. Low-dose heparin appears to reduce the incidence of thrombosis with TPN when provided continuously in sufficient amounts.  相似文献   

17.
The pattern of sepsis among 56 children admitted for various forms of cancer to the King Khalid University Hospital, Riyadh, Kingdom of Saudi Arabia during a 6-year period, was retrospectively reviewed. A total of 148 febrile neutropenic episodes occurred and 55 of these, in 40 patients, were associated with positive blood cultures. The isolates were Gram-positive bacteria in 54% of instances, Gram-negative bacteria in 39.4% and Candida in 6.6% and polymicrobial sepsis occurred in five patients. Profound neutropenia (neutrophil counts less than 0.1 x 10(9) l-1) significantly predisposed to Gram-negative sepsis (P less than 0.02), which was responsible for about one-third of deaths in this series. Central venous catheters were present prior to 49% of the septicaemic episodes, but were not significantly associated with either increased Gram-negative or Gram-positive bacterial sepsis. However, all four cases of candidaemia occurred in patients with a central venous catheter in situ, and it is recommended that early empirical treatment for candida be considered in all febrile neutropenic cancer patients with central venous catheters.  相似文献   

18.
A retrospective study in 38 children (1 day to 7 years) on total parenteral nutrition (TPN) (1 month-24 months) with a central venous catheter (CVC) evaluated the contribution of two-dimensional echocardiography (2D) and M-mode in the follow-up of CVC location and early diagnosis of related complications. Fifty examinations were performed routinely in 21 patients (group I) and 40 in 17 patients for sepsis of the CVC or clinical suspicion of thrombosis (group II). The tip of the CVC was located in the upper right atrium in 17 cases (45%), superior vena cava in 14 cases (37%), jugular or subclavian vein in 5 cases (13%), and was not visualized in 2 cases (15%). In group I, 2D was normal in 19 cases, and catheter thrombosis suspected in 2 was not confirmed by digital angiography (DA). In group II, 2D was normal in 11 cases. In 6 patients, subxiphoid and suprasternal planes identified superior vena cava thrombus in the right atrium (DA confirmed the diagnosis in 2). In 2 pulmonary embolism occurred (1 case died); the remaining patients were successfully treated by medical therapy and removal of the catheter. Echocardiography is a useful noninvasive technique to control CVC tip location and follow-up. In this study, the sensitivity of cardiac thrombus detection by echocardiography was 100% and the specificity 93%; this method appeared, therefore, appropriate for early detection of cardiac thrombosis in pediatric patients on TPN.  相似文献   

19.
BACKGROUND AND AIMS: Total parenteral nutrition (TPN) is typically delivered through catheters inserted into the superior vena cava (SVC) via a subclavian or internal jugular vein approach. A peripherally-inserted central venous catheter (PICC), utilizing a cephalic or basilic venous approach, may provide a safe alternative to the standard catheter approach and, because non-physician providers can insert the PICC, may introduce a potential cost-savings to health care institutions. We sought to determine if PICC lines are safer and more cost-effective than the standard central venous catheter approach for hospitalized patients who require TPN. METHODS: One hundred and two hospitalized patients (age range, 18-88 years) who required TPN were prospectively randomized to receive therapy via a centrally-inserted subclavian catheter (n=51) or a peripherally-inserted PICC line (n=51). The primary end-point was the development of a complication requiring catheter removal. Other end-points included catheter infection and thrombophlebitis. Cost associated with insertion and maintenance of each catheter was also studied. RESULTS: Complication-free delivery rate (without the need to remove or replace the catheter) was 67% for subclavian catheters and 46% for PICC lines (P<0.05). The overall infection rate was 4.9 per 1000 catheter days and was similar for each catheter type (P=0.68). PICC lines were associated with higher rates of clinically-evident thrombophlebitis (P<0.01), difficult insertion attempts (P<0.05), and malposition on insertion (P<0.05). No catheter complications resulted in significant long-term morbity or mortality. No significant difference was noted between the two catheter types in terms of aborted insertion attempts (P=0.18), dislodgement (P=0.12), or line occlusion (P=0.25). After standardizing costs for each hospital, the direct institutional costs for insertion and maintenance of PICC lines (US$22.32+/-2.74 per day) was greater than that for subclavian lines (US$16.20+/-2.96 per day;P<0.05). CONCLUSION: PICC catheters have higher thrombophlebitis rates and are more difficult to insert into certain patients when compared to the standard subclavian approach for central venous access in hospitalized patients who require TPN. Because of this, PICCs may be less cost-effective than currently believed because of the difficulty in inserting and maintaining the catheter.  相似文献   

20.
Catheter tip position in central vein thrombosis   总被引:2,自引:0,他引:2  
Clinical central venous thrombosis (CVT) was found to be associated with a catheter tip position in the superior vena cava (SVC), but not in the right atrium (RA), in patients receiving a standard parenteral nutrition regime in which dextrose was the sole energy source. CVT was rare with standard lipid containing three in one mixes, even when the catheter tip lay in the SVC. The reasons for this are discussed and the complications associated with catheter tip position are reviewed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号