首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到15条相似文献,搜索用时 15 毫秒
1.
Arterial spin labeling (ASL) imaging is a powerful magnetic resonance imaging technique that allows to quantitatively measure blood perfusion non-invasively, which has great potential for assessing tissue viability in various clinical settings. However, the clinical applications of ASL are currently limited by its low signal-to-noise ratio (SNR), limited spatial resolution, and long imaging time. In this work, we propose an unsupervised deep learning-based image denoising and reconstruction framework to improve the SNR and accelerate the imaging speed of high resolution ASL imaging. The unique feature of the proposed framework is that it does not require any prior training pairs but only the subject's own anatomical prior, such as T1-weighted images, as network input. The neural network was trained from scratch in the denoising or reconstruction process, with noisy images or sparely sampled k-space data as training labels. Performance of the proposed method was evaluated using in vivo experiment data obtained from 3 healthy subjects on a 3T MR scanner, using ASL images acquired with 44-min acquisition time as the ground truth. Both qualitative and quantitative analyses demonstrate the superior performance of the proposed txtc framework over the reference methods. In summary, our proposed unsupervised deep learning-based denoising and reconstruction framework can improve the image quality and accelerate the imaging speed of ASL imaging.  相似文献   

2.
Mouse models are increasingly used to study the pathophysiology of myocardial infarction in vivo. In this area, MRI has become the gold standard imaging modality, because it combines high spatial and temporal resolution functional imaging with a large variety of methods to generate soft tissue contrast. In addition, (target-specific) MRI contrast agents can be employed to visualize different processes in the cascade of events following myocardial infarction. Here, the MRI sequence has a decisive role in the detection sensitivity of a contrast agent. However, a straightforward translation of clinically available protocols for human cardiac imaging to mice is not feasible, because of the small size of the mouse heart and its extremely high heart rate. This has stimulated intense research in the development of cardiac MRI protocols specifically tuned to the mouse with regard to timing parameters, acquisition strategies, and ECG- and respiratory-triggering methods to find an optimal trade-off between sensitivity, scan time, and image quality. In this review, a detailed analysis is given of the pros and cons of different mouse cardiac MR imaging methodologies and their application in contrast-enhanced MRI of myocardial infarction.  相似文献   

3.
Sickle cell anemia (SCA) is a genetic disorder resulting in reduced oxygen carrying capacity and elevated stroke risk. Pseudo‐continuous arterial spin labeling (pCASL) measures of cerebral blood flow (CBF) may have relevance for stroke risk assessment; however, the effects of elevated flow velocity and reduced bolus arrival time (BAT) on CBF quantification in SCA patients have not been thoroughly characterized, and pCASL model parameters used in healthy adults are often applied to patients with SCA. Here, cervical arterial flow velocities and pCASL labeling efficiencies were computed in adults with SCA (n = 19) and age‐ and race‐matched controls without sickle trait (n = 7) using pCASL in sequence with phase contrast MR angiography (MRA). Controls (n = 7) and a subgroup of patients (n = 8) also underwent multi‐post‐labeling‐delay pCASL for BAT assessment. Mean flow velocities were elevated in SCA adults (velocity = 28.3 ± 4.1 cm/s) compared with controls (velocity = 24.5 ± 3.8 cm/s), and mean pCASL labeling efficiency (α) was reduced in SCA adults (α = 0.72) relative to controls (α = 0.91). In patients, mean whole‐brain CBF from phase contrast MRA was 91.8 ± 18.1 ml/100 g/min, while mean pCASL CBF when assuming a constant labeling efficiency of 0.86 was 75.2 ± 17.3 ml/100 g/min (p < 0.01), resulting in a mean absolute quantification error of 23% when a labeling efficiency appropriate for controls was assumed. This difference cannot be accounted for by BAT (whole‐brain BAT: control, 1.13 ± 0.06 s; SCA, 1.02 ± 0.09 s) or tissue T1 variation. In conclusion, BAT variation influences pCASL quantification less than elevated cervical arterial velocity and labeling efficiency variation in SCA adults; thus, a lower labeling efficiency (α = 0.72) or subject‐specific labeling efficiency should be incorporated for SCA patients.  相似文献   

4.
Prostate perfusion has the potential to become an important pathophysiological marker for the monitoring of disease progression or the assessment of the therapeutic response of prostate cancer. The feasibility of arterial spin labeling, an MRI approach for the measurement of perfusion without an exogenous contrast agent, is demonstrated in the prostate for the first time. Although various arterial spin labeling methods have been demonstrated previously in highly perfused organs, such as the brain and kidneys, the prospect of obtaining such measurements in the prostate is challenging because of the relatively low blood flow, long transit times, susceptibility‐induced image distortion and local motion. However, despite these challenges, this study demonstrates that, with a whole‐body transmit coil and external receiver array, global prostate perfusion can be measured with arterial spin labeling at 3 T. In five healthy subjects with a mean age of 44 years, the mean total prostate blood flow was measured to be 25.8 ± 7.1 mL/100 cm3/min, with an estimated bolus duration and arterial transit time of 884 ± 209 ms and 721 ± 131 ms, respectively. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

5.
To quantify noninvasively myocardial blood flow (MBF) and MBF reserve in isoflurane‐anesthetized rats using the Look‐Locker flow‐alternating inversion recovery gradient‐echo arterial spin labeling technique (LLFAIRGE‐ASL), and to compare the results with the fluorescent microsphere (FM) technique. Male Wistar rats (weight = 200–240 g, n = 21) were anesthetized with 2.0% isoflurane. Hemodynamic parameters were recorded. In seven rats, MBF was assessed on a Bruker Biospec 4.7T MR system using an ECG‐ and respiration‐gated LLFAIRGE‐ASL (pixel size = 234 × 468µm2, TE = 1.52ms) at rest and during adenosine infusion (140 µg/kg/min). A mixture of 200 000 FM was injected into a second group of rats at rest and during adenosine infusion (n = 7 each), under similar physiologic conditions. Hearts and skeletal muscle samples were processed for fluorescence spectroscopy. Two‐tailed unpaired, paired Student's t‐test and ANOVA were used to compare groups. MBF measured with LLFAIRGE‐ASL was 5.2 ± 1.0 mL/g/min at rest and 13.3 ± 3.0 mL/g/min during adenosine infusion. Results obtained with fluorescent microspheres yielded 5.9 ± 2.3 mL/g/min (nonsignificant vs. LLFAIRGE‐ASL, p = 0.9) at rest and 13.1 ± 2.1 mL/g/min (nonsignificant vs. LLFAIRGE‐ASL, p = 0.4) during adenosine infusion. Myocardial blood flow reserve measured using LLFAIRGE‐ASL and FM were not significantly different (2.5 ± 0.6 vs. 2.4 ± 0.9, respectively; p = 0.8). Hemodynamic parameters during the experiments were not different between the groups. The myocardial blood flow reserve determined under isoflurane anesthesia was 2.5 ± 0.6, which was not different from the value obtained with FM. LLFAIRGE‐ASL provided MBF maps with high spatial resolution in rats under isoflurane anesthesia. LLFAIRGE‐ASL is a noninvasive measure to assess myocardial blood flow reserve and provides an interesting tool for cardiovascular research. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

6.
Perfusion MRI has the potential to provide pathophysiological biomarkers for the evaluating, staging and therapy monitoring of prostate cancer. The objective of this study was to explore the feasibility of noninvasive arterial spin labeling (ASL) to detect prostate cancer in the peripheral zone and to investigate the correlation between the blood flow (BF) measured by ASL and the pharmacokinetic parameters Ktrans (forward volume transfer constant), kep (reverse reflux rate constant between extracellular space and plasma) and ve (the fractional volume of extracellular space per unit volume of tissue) measured by dynamic contrast‐enhanced (DCE) MRI in patients with prostate cancer. Forty‐three consecutive patients (ages ranging from 49 to 86 years, with a median age of 74 years) with pathologically confirmed prostate cancer were recruited. An ASL scan with four different inversion times (TI = 1000, 1200, 1400 and 1600 ms) and a DCE‐MRI scan were performed on a clinical 3.0 T GE scanner. BF, Ktrans, kep and ve maps were calculated. In order to determine whether the BF values in the cancerous area were statistically different from those in the noncancerous area, an independent t‐test was performed. Spearman's bivariate correlation was used to assess the relationship between BF and the pharmacokinetic parameters Ktrans, kep and ve. The mean BF values in the cancerous areas (97.1 ± 30.7, 114.7 ± 28.7, 102.3 ± 22.5, 91.2 ± 24.2 ml/100 g/min, respectively, for TI = 1000, 1200, 1400, 1600 ms) were significantly higher (p < 0.01 for all cases) than those in the noncancerous regions (35.8 ± 12.5, 42.2 ± 13.7, 53.5 ± 19.1, 48.5 ± 13.5 ml/100 g/min, respectively). Significant positive correlations (p < 0.01 for all cases) between BF and the pharmacokinetic parameters Ktrans, kep and ve were also observed for all four TI values (r = 0.671, 0.407, 0.666 for TI = 1000 ms; 0.713, 0.424, 0.698 for TI = 1200 ms; 0.604, 0.402, 0.595 for TI = 1400 ms; 0.605, 0.422, 0.548 for TI = 1600 ms). It can be seen that the quantitative ASL measurements show significant differences between cancerous and benign tissues, and exhibit strong to moderate correlations with the parameters obtained using DCE‐MRI. These results show the promise of ASL as a noninvasive alternative to DCE‐MRI. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

7.
The forward volumetric transfer constant (Ktrans), a physiological parameter extracted from dynamic contrast‐enhanced (DCE) MRI, is weighted by vessel permeability and tissue blood flow. The permeability × surface area product per unit mass of tissue (PS) in brain tumors was estimated in this study by combining the blood flow obtained through pseudo‐continuous arterial spin labeling (PCASL) and Ktrans obtained through DCE MRI. An analytical analysis and a numerical simulation were conducted to understand how errors in the flow and Ktrans estimates would propagate to the resulting PS. Fourteen pediatric patients with brain tumors were scanned on a clinical 3‐T MRI scanner. PCASL perfusion imaging was performed using a three‐dimensional (3D) fast‐spin‐echo readout module to determine blood flow. DCE imaging was performed using a 3D spoiled gradient‐echo sequence, and the Ktrans map was obtained with the extended Tofts model. The numerical analysis demonstrated that the uncertainty of PS was predominantly dependent on that of Ktrans and was relatively insensitive to the flow. The average PS values of the whole tumors ranged from 0.006 to 0.217 min?1, with a mean of 0.050 min?1 among the patients. The mean Ktrans value was 18% lower than the PS value, with a maximum discrepancy of 25%. When the parametric maps were compared on a voxel‐by‐voxel basis, the discrepancies between PS and Ktrans appeared to be heterogeneous within the tumors. The PS values could be more than two‐fold higher than the Ktrans values for voxels with high Ktrans levels. This study proposes a method that is easy to implement in clinical practice and has the potential to improve the quantification of the microvascular properties of brain tumors. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

8.
Diffusion‐weighted imaging (DWI) provides information on tissue microstructure. Single‐shot echo planar imaging (EPI) is the most common technique for DWI applications in the brain, but is prone to geometric distortions and signal voids. Rapid acquisition with relaxation enhancement [RARE, also known as fast spin echo (FSE)] imaging presents a valuable alternative to DWI with high anatomical accuracy. This work proposes a multi‐shot diffusion‐weighted RARE‐EPI hybrid pulse sequence, combining the anatomical integrity of RARE with the imaging speed and radiofrequency (RF) power deposition advantage of EPI. The anatomical integrity of RARE‐EPI was demonstrated and quantified by center of gravity analysis for both morphological images and diffusion‐weighted acquisitions in phantom and in vivo experiments at 3.0 T and 7.0 T. The results indicate that half of the RARE echoes in the echo train can be replaced by EPI echoes whilst maintaining anatomical accuracy. The reduced RF power deposition of RARE‐EPI enabled multiband RF pulses facilitating simultaneous multi‐slice imaging. This study shows that diffusion‐weighted RARE‐EPI has the capability to acquire high fidelity, distortion‐free images of the eye and the orbit. It is shown that RARE‐EPI maintains the immunity to B0 inhomogeneities reported for RARE imaging. This benefit can be exploited for the assessment of ocular masses and pathological changes of the eye and the orbit.  相似文献   

9.
Arterial transit time (ATT) prolongation causes an error of cerebral blood flow (CBF) measurement during arterial spin labeling (ASL). To improve the accuracy of ATT and CBF in patients with prolonged ATT, we propose a robust ATT and CBF estimation method for clinical practice. The proposed method consists of a three‐delay Hadamard‐encoded pseudo‐continuous ASL (H‐pCASL) with an additional‐encoding and single‐delay with long‐labeled long‐delay (1dLLLD) acquisition. The additional‐encoding allows for the reconstruction of a single‐delay image with long‐labeled short‐delay (1dLLSD) in addition to the normal Hadamard sub‐bolus images. Five different images (normal Hadamard 3 delay, 1dLLSD, 1dLLLD) were reconstructed to calculate ATT and CBF. A Monte Carlo simulation and an in vivo study were performed to access the accuracy of the proposed method in comparison to normal 7‐delay (7d) H‐pCASL with equally divided sub‐bolus labeling duration (LD). The simulation showed that the accuracy of CBF is strongly affected by ATT. It was also demonstrated that underestimation of ATT and CBF by 7d H‐pCASL was higher with longer ATT than with the proposed method. Consistent with the simulation, the 7d H‐pCASL significantly underestimated the ATT compared to that of the proposed method. This underestimation was evident in the distal anterior cerebral artery (ACA; P = 0.0394) and the distal posterior cerebral artery (PCA; 2 P = 0.0255). Similar to the ATT, the CBF was underestimated with 7d H‐pCASL in the distal ACA (P = 0.0099), distal middle cerebral artery (P = 0.0109), and distal PCA (P = 0.0319) compared to the proposed method. Improving the SNR of each delay image (even though the number of delays is small) is crucial for ATT estimation. This is opposed to acquiring many delays with short LD. The proposed method confers accurate ATT and CBF estimation within a practical acquisition time in a clinical setting.  相似文献   

10.
Arterial spin labeling (ASL) offers MRI measurement of cerebral blood flow (CBF) in vivo, and may offer clinical diagnostic utility in populations such as those with early Alzheimer's disease (AD). In the current study, we investigated the reliability and precision of a pseudo‐continuous ASL (pcASL) sequence that was performed two or three times within one hour on eight young normal control subjects, and 14 elderly subjects including 11 with normal cognition, one with AD and two with Mild Cognitive Impairment (MCI). Six of these elderly subjects including one AD, two MCIs and three controls also received 15O‐water positron emission tomography (PET) scans 2 h before their pcASL MR scan. The instrumental reliability of pcASL was evaluated with the intraclass correlation coefficient (ICC). The ICCs were greater than 0.90 in pcASL global perfusion measurements for both the young and the elderly groups. The cross‐modality perfusion imaging comparison yielded very good global and regional agreement in global gray matter and the posterior cingulate cortex. Significant negative correlation was found between age and the gray/white matter perfusion ratio (r = –0.62, p < 0.002). The AD and MCI patients showed the lowest gray/white matter perfusion ratio among all the subjects. The data suggest that pcASL provides a reliable whole brain CBF measurement in young and elderly adults whose results converge with those obtained with the traditional 15O‐water PET perfusion imaging method. pcASL perfusion MRI offers an alternative method for non‐invasive in vivo examination of early pathophysiological changes in AD. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
Cardiac T1 mapping allows non‐invasive imaging of interstitial diffuse fibrosis. Myocardial T1 is commonly calculated by voxel‐wise fitting of the images acquired using balanced steady‐state free precession (SSFP) after an inversion pulse. However, SSFP imaging is sensitive to B1 and B0 imperfection, which may result in additional artifacts. A gradient echo (GRE) imaging sequence has been used for myocardial T1 mapping; however, its use has been limited to higher magnetic field to compensate for the lower signal‐to‐noise ratio (SNR) of GRE versus SSFP imaging. A slice‐interleaved T1 mapping (STONE) sequence with SSFP readout (STONE–SSFP) has been recently proposed for native myocardial T1 mapping, which allows longer recovery of magnetization (>8 R–R) after each inversion pulse. In this study, we hypothesize that a longer recovery allows higher SNR and enables native myocardial T1 mapping using STONE with GRE imaging readout (STONE–GRE) at 1.5T. Numerical simulations and phantom and in vivo imaging were performed to compare the performance of STONE–GRE and STONE–SSFP for native myocardial T1 mapping at 1.5T. In numerical simulations, STONE–SSFP shows sensitivity to both T2 and off resonance. Despite the insensitivity of GRE imaging to T2, STONE–GRE remains sensitive to T2 due to the dependence of the inversion pulse performance on T2. In the phantom study, STONE–GRE had inferior accuracy and precision and similar repeatability as compared with STONE–SSFP. In in vivo studies, STONE–GRE and STONE–SSFP had similar myocardial native T1 times, precisions, repeatabilities and subjective T1 map qualities. Despite the lower SNR of the GRE imaging readout compared with SSFP, STONE–GRE provides similar native myocardial T1 measurements, precision, repeatability, and subjective image quality when compared with STONE–SSFP at 1.5T.  相似文献   

12.
Activated choline metabolism is a hallmark of carcinogenesis and tumor progression, which leads to elevated levels of phosphocholine and glycerophosphocholine in all types of cancer tested so far. Magnetic resonance spectroscopy applications have played a key role in detecting these elevated choline phospholipid metabolites. To date, the majority of cancer‐related studies have focused on phosphocholine and the Kennedy pathway, which constitutes the biosynthesis pathway for membrane phosphatidylcholine. Fewer and more recent studies have reported on the importance of glycerophosphocholine in cancer. In this review article, we summarize the recent literature on glycerophosphocholine metabolism with respect to its cancer biology and its detection by magnetic resonance spectroscopy applications.  相似文献   

13.
Vessel‐selective dynamic angiograms provide a wealth of useful information about the anatomical and functional status of arteries, including information about collateral flow and blood supply to lesions. Conventional x‐ray techniques are invasive and carry some risks to the patient, so non‐invasive alternatives are desirable. Previously, non‐contrast dynamic MRI angiograms based on arterial spin labeling (ASL) have been demonstrated using both spoiled gradient echo (SPGR) and balanced steady‐state free precession (bSSFP) readout modules, but no direct comparison has been made, and bSSFP optimization over a long readout period has not been fully explored. In this study bSSFP and SPGR are theoretically and experimentally compared for dynamic ASL angiography. Unlike SPGR, bSSFP was found to have a very low ASL signal attenuation rate, even when a relatively large flip angle and short repetition time were used, leading to a threefold improvement in the measured signal‐to‐noise ratio (SNR) efficiency compared with SPGR. For vessel‐selective applications, SNR efficiency can be further improved over single‐artery labeling methods by using a vessel‐encoded pseudo‐continuous ASL (VEPCASL) approach. The combination of a VEPCASL preparation with a time‐resolved bSSFP readout allowed the generation of four‐dimensional (4D; time‐resolved three‐dimensional, 3D) vessel‐selective cerebral angiograms in healthy volunteers with 59 ms temporal resolution. Good quality 4D angiograms were obtained in all subjects, providing comparable structural information to 3D time‐of‐flight images, as well as dynamic information and vessel selectivity, which was shown to be high. A rapid 1.5 min dynamic two‐dimensional version of the sequence yielded similar image features and would be suitable for a busy clinical protocol. Preliminary experiments with bSSFP that included the extracranial vessels showed signal loss in regions of poor magnetic field homogeneity. However, for intracranial vessel‐selective angiography, the proposed bSSFP VEPCASL sequence is highly SNR efficient and could provide useful information in a range of cerebrovascular diseases. © 2016 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd.  相似文献   

14.
Short‐TE 1H MRS has great potential for brain cancer diagnostics. A major difficulty in the analysis of the spectra is the contribution from short‐T2 signal components, mainly coming from mobile lipids. This complicates the accurate estimation of the spectral parameters of the resonance lines from metabolites, so that a qualitative to semi‐quantitative interpretation of the spectra dominates in practice. One solution to overcome this difficulty is to measure and estimate the short‐T2 signal component and to subtract it from the total signal, thus leaving only the metabolite signals. The technique works well when applied to spectra obtained from healthy individuals, but requires some optimisation during data acquisition. In the clinical setting, time constraints hardly allow this. Here, we propose an iterative estimation of the short‐T2 signal component, acquired in a single acquisition after measurement of the full spectrum. The method is based on QUEST (quantitation based on quantum estimation) and allows the refinement of the estimate of the short‐T2 signal component after measurement. Thus, acquisition protocols used on healthy volunteers can also be used on patients without further optimisation. The aim is to improve metabolite detection and, ultimately, to enable the estimation of the glutamine and glutamate signals distinctly. These two metabolites are of great interest in the characterisation of brain cancer, gliomas in particular. When applied to spectra from healthy volunteers, the new algorithm yields similar results to QUEST and direct subtraction of the short‐T2 signal component. With patients, up to 12 metabolites and, at least, seven can be quantified in each individual brain tumour spectrum, depending on the metabolic state of the tumour. The refinement of the short‐T2 signal component significantly improves the fitting procedure and produces a separate short‐T2 signal component that can be used for the analysis of mobile lipid resonances. Thus, in brain tumour spectra, distinct estimates of signals from glutamate and glutamine are possible. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

15.
Magnetic resonance‐based approaches to obtain metabolic information on cancer have been explored for decades. Electron paramagnetic resonance (EPR) has been developed to pursue metabolic profiling and successfully used to monitor several physiologic parameters such as pO2, pH, and redox status. All these parameters are associated with pathophysiology of various diseases. Especially in oncology, cancer hypoxia has been intensively studied because of its relationship with metabolic alterations, acquiring treatment resistance, or a malignant phenotype. Thus, pO2 imaging leads to an indirect metabolic assessment in this regard. Proton electron double‐resonance imaging (PEDRI) is an imaging technique to visualize EPR by using the Overhauser effect. Most biological parameters assessed in EPR can be visualized using PEDRI. However, EPR and PEDRI have not been evaluated sufficiently for clinical application due to limitations such as toxicity of the probes or high specific absorption rate. Hyperpolarized (HP) 13C MRI is a novel imaging technique that can directly visualize the metabolic profile. Production of metabolites of the HP 13C probe delivered to target tissue are evaluated in this modality. Unlike EPR or PEDRI, which require the injection of radical probes, 13C MRI requires a probe that can be physiologically metabolized and efficiently hyperpolarized. Among several methods for hyperpolarizing probes, dissolution dynamic nuclear hyperpolarization is a widely used technique for in vivo imaging. Pyruvate is the most suitable probe for HP 13C MRI because it is part of the glycolytic pathway and the high efficiency of pyruvate‐to‐lactate conversion is a distinguishing feature of cancer. Its clinical applicability also makes it a promising metabolic imaging modality. Here, we summarize the applications of these indirect and direct MR‐based metabolic assessments focusing on pO2 and pyruvate‐to‐lactate conversion. The two parameters are strongly associated with each other, hence the acquired information is potentially interchangeable when evaluating treatment response to oxygen‐dependent cancer therapies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号