共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
4.
Dhiren Sheth Guy Cafri Maria C. S. Inacio Elizabeth W. Paxton Robert S. Namba 《Clinical orthopaedics and related research》2015,473(11):3401-3408
Background
Lack of consensus continues regarding the benefit of anteriorly based surgical approaches for primary total hip arthroplasty (THA). The purpose of this study was to evaluate the risk of aseptic revision, septic revision, and dislocations for various approaches used in primary THAs from a community-based healthcare organization.Questions/purposes
(1) What is the incidence of aseptic revision, septic revision, and dislocation for primary THA in a large community-based healthcare organization? (2) Does the risk of aseptic revision, septic revision, and dislocation vary by THA surgical approach?Methods
The Kaiser Permanente Total Joint Replacement Registry was used to identify primary THAs performed between April 1, 2001 and December 31, 2011. Endpoints were septic revisions, aseptic revisions, and dislocations. The exposure of interest was surgical approach (posterior, anterolateral, direct lateral, direct anterior). Patient, implant, surgeon, and hospital factors were evaluated as possible confounders. Survival analysis was performed with marginal multivariate Cox models. Hazard ratios (HRs) and 95% confidence intervals (CIs) are reported. A total of 42,438 primary THAs were available for analysis of revision outcomes and 22,237 for dislocation. Median followup was 3 years (interquartile range, 1–5 years). The registry’s voluntary participation is 95%. The most commonly used approach was posterior (75%, N = 31,747) followed by anterolateral (10%, N = 4226), direct anterior (4%, N = 1851), and direct lateral (2%, N = 667).Results
During the study period 785 hips (2%) were revised for aseptic reasons, 213 (0.5%) for septic reasons, and 276 (1%) experienced a dislocation. The revision rate per 100 years of observation was 0.54 for aseptic revisions, 0.15 for septic revisions, and 0.58 for dislocations. There were no differences in adjusted risk of revision (either septic or aseptic) across the different THA approaches. However, the anterolateral approach (adjusted HR, 0.29; 95% CI, 0.13–0.63, p = 0.002) and direct anterior approach (adjusted HR, 0.44; 95% CI, 0.22–0.87, p = 0.017) had a lower risk of dislocation relative to the posterior approach. There were no differences in any of the outcomes when comparing the direct anterior approach with the anterolateral approach.Conclusions
Anterior and anterolateral surgical approaches had the advantage of a lower risk of dislocation without increasing the risk of early revision.Level of Evidence
Level III, therapeutic study. 相似文献5.
Olli Lainiala Aleksi Reito Petra Elo Jorma Pajam?ki Timo Puolakka Antti Eskelinen 《Clinical orthopaedics and related research》2015,473(7):2305-2313
Background
High revision rates attributable to adverse reactions to metal debris have been reported for total hip arthroplasties (THAs) with metal-on-metal implants and hip resurfacings. The effect of revision on blood metal ion levels is described only in small series, the clinical results of revisions have been contradictory, and concerns regarding component loosening have been presented.Questions/purposes
We asked: (1) Did revision surgery result in a reduction to normal for whole blood cobalt (Co) and chromium (Cr) levels (2) What changes to the Oxford Hip Score were observed after revision of these hips with metal-on-metal implants? (3) Were there radiologic signs of component loosening observed on 1-year followup radiographs?Methods
Between September 2010 and April 2013, 154 patients (166 hips) who had THAs with implantation of the Articular Surface Replacement (ASR™) system and 44 patients (49 hips) who had hip resurfacings of the ASR™ implant underwent revision surgery for adverse reactions to metal debris at our institution, after recall of these components in August 2010. General indications for revision of these implants included a symptomatic hip and/or a predominantly solid pseudotumor seen on cross-sectional imaging. Since recall, patients were systematically followed after revision with Oxford Hip Score questionnaires, blood Co and Cr measurements (analyzed from whole blood with dynamic reaction-cell inductively coupled plasma-mass spectrometry), and plain radiographs at 2 and 12 months after revision surgery, and thereafter at 2-year intervals. Preoperative and 1-year postoperative blood Co and Cr values were available for 93% (185 of 198 patients), Oxford Hip Score for 76% (151 of 198 patients), and plain radiographs for all patients.Results
Whole-blood levels of Co decreased below the 7 ppb cut-off value in all patients with revision of unilateral THA or resurfacing, however, blood Cr levels remained elevated in four of 90 patients (4%) in the unilateral THA group and four of 34 patients (12%) in the unilateral resurfacing group. All had ultrahigh (> 40 ppb) preoperative Cr levels. Cr levels remained elevated in six of the patients at the 3-year followup. The median Oxford Hip Score improved from preoperative to 1-year postoperative in the unilateral THA group (38 [4–48] to 40 [9–48], p = 0.049) and in the unilateral hip resurfacing group (37.5 [9–48] to 44 [13–48], p = 0.011). No improvement was seen in patients who had bilateral THAs (37 [14–48] to 41 [9–48], p = 0.196). Only minor radiographic abnormalities were seen, with no suspicion of component loosening.Conclusions
Metal-on-metal THAs and resurfacings have raised concerns and an emerging rate of revisions has been seen for many different metal-on-metal hip prostheses worldwide. Revision surgery seems to be effective for removal of the systemic metal ion burden, even though blood Cr remained elevated in a few patients for more than 3 years after removal of the metal-on-metal implant. In patients with bilateral metal-on-metal hip replacements the remaining metal-on-metal implant still supplies the body with Co and Cr ions after a unilateral revision, and therefore followup should be continued. Adverse reactions to metal debris do not seem to compromise implant ingrowth after revision surgery. However, as some of our patients still had a poor functional outcome at 12 months after revision surgery, additional research is warranted to determine the optimal time for patients to undergo revision surgery for suspected adverse reactions to metal debris.Level of Evidence
Level IV, therapeutic study. 相似文献6.
William M. Mihalko MD PhD Markus A. Wimmer PhD Carol A. Pacione BS Michel P. Laurent PhD Robert F. Murphy MD Carson Rider BS 《Clinical orthopaedics and related research》2014,472(12):3747-3758
Background
Total hip arthroplasty (THA) continues to be one of the most successful surgical procedures in the medical field. However, over the last two decades, the use of modularity and alternative bearings in THA has become routine. Given the known problems associated with hard-on-hard bearing couples, including taper failures with more modular stem designs, local and systemic effects from metal-on-metal bearings, and fractures with ceramic-on-ceramic bearings, it is not known whether in aggregate the survivorship of these implants is better or worse than the metal-on-polyethylene bearings that they sought to replace.Questions/purposes
Have alternative bearings (metal-on-metal and ceramic-on-ceramic) and implant modularity decreased revision rates of primary THAs?Methods
In this systematic review of MEDLINE and EMBASE, we used several Boolean search strings for each topic and surveyed national registry data from English-speaking countries. Clinical research (Level IV or higher) with ≥ 5 years of followup was included; retrieval studies and case reports were excluded. We included registry data at ≥ 7 years followup. A total of 32 studies (and five registry reports) on metal-on-metal, 19 studies (and five registry reports) on ceramic-on-ceramic, and 20 studies (and one registry report) on modular stem designs met inclusion criteria and were evaluated in detail. Insufficient data were available on metal-on-ceramic and ceramic-on-metal implants, and monoblock acetabular designs were evaluated in another recent systematic review so these were not evaluated here.Results
There was no evidence in the literature that alternative bearings (either metal-on-metal or ceramic-on-ceramic) in THA have decreased revision rates. Registry data, however, showed that large head metal-on-metal implants have lower 7- to 10-year survivorship than do standard bearings. In THA, modular exchangeable femoral neck implants had a lower 10-year survival rate in both literature reviews and in registry data compared with combined registry primary THA implant survivorship.Conclusions
Despite improvements in implant technology, there is no evidence that alternative bearings or modularity have resulted in decreased THA revision rates after 5 years. In fact, both large head metal-on-metal THA and added modularity may well lower survivorship and should only be used in select cases in which the mission cannot be achieved without it. Based on this experience, followup and/or postmarket surveillance studies should have a duration of at least 5 years before introducing new alternative bearings or modularity on a widespread scale. 相似文献7.
8.
Background
Implant stability is considered vital to long-time implant survival in total hip arthroplasty (THA), since loose implants are reported to be a major cause of hip revision. There is an association between early implant micromotion and increased risk of revision. More implant-specific data are needed to establish acceptable levels of early implant movement.Materials and methods
Thirty-five patients (36 hips) undergoing Charnley THA were followed with repeated clinical, radiographic, and radiostereometric analysis (RSA) over 5 years. Twenty-three patients attended 5 years postoperatively.Results
The patient group was well functioning based on the radiological and clinical evaluations. The stems constantly moved up to 5 years postoperatively, with subsidence, retroversion, and varus tilt, based on the RSA.Conclusion
Continuous movement of the Charnley stem was observed up to 5 years postoperatively in a well-functioning patient group. The migration data presented herein could be useful when defining acceptable migration limits for certain types of cemented femoral stems. 相似文献9.
Marrigje F. Meijer Inge H. F. Reininga Alexander L. Boerboom Martin Stevens Sjoerd K. Bulstra 《International orthopaedics》2013,37(3):415-419
Purpose
Revision total knee arthroplasty (rTKA) is a complex procedure. Depending on the degree of ligament and bone damage, either primary or revision implants are used. The purpose of this study was to compare survival rates of primary implants with revision implants when used during rTKA.Methods
A retrospective comparative study was conducted between 1998 and 2009 during which 69 rTKAs were performed on 65 patients. Most common indications for revision were infection (30 %), aseptic loosening (25 %) and wear/osteolysis (25 %). During rTKA, a primary implant was used in nine knees and a revision implant in 60.Results
Survival of primary implants was 100 % at one year, 73 % [95 % confidence interval (CI) 41–100] at two years and 44 % (95 % CI 7–81) at five years. Survival of revision implants was 95 % (95 % CI 89–100) at one year, 92 % (95 % CI 84–99) at two years and 92 % (95 % CI 84–99) at five years. Primary implants had a significantly worse survival rate than revision implants when implanted during rTKA [P = 0.039 (hazard ratio = 4.56, 95 % CI 1.08–19.27)].Conclusions
Based on these results, it has to be considered whether primary implants are even an option during rTKA. 相似文献10.
Martijn A. J. te Stroet Wim H. C. Rijnen Jean W. M. Gardeniers Albert van Kampen B. Willem Schreurs 《Clinical orthopaedics and related research》2015,473(12):3867-3875
Background
The increasing number of total hip arthroplasties (THAs) performed in younger patients will inevitably generate larger numbers of revision procedures for this specific group of patients. Unfortunately, no satisfying revision method with acceptable survivorship 10 years after revision has been described for these patients so far.Questions/purposes
The purposes of this study were to (1) analyze the clinical outcome; (2) complication rate; (3) survivorship; and (4) radiographic outcome of cemented revision THA performed with impaction bone grafting (IBG) on both the acetabular and femoral sides in one surgery in patients younger than 55 years old.Methods
During the period 1991 to 2007, 86 complete THA revisions were performed at our institution in patients younger than 55 years. In 34 of these 86 revisions (40%), IBG was used on both the acetabular and femoral sides in 33 patients. Mean patient age at revision surgery was 46.4 years (SD 7.6). No patient was lost to followup, but three patients died during followup. None of the deaths were related to the revision surgery. The mean followup for the surviving hips was 11.7 years (SD 4.6). We also analyzed complication rate.Results
The mean Harris hip score improved from 55 (SD 18) preoperatively to 80 points (SD 16) at latest followup (p = 0.009). Six hips underwent a rerevision (18%): in four patients, both components were rerevised; and in two hips, only the cup was revised. Patient 10-year survival rate with the endpoint of rerevision for any component for any reason was 87% (95% confidence interval [CI], 67%–95%) and with the endpoint of rerevision for aseptic loosening, the survival rate was 97% (95% CI, 80%–100%). In total six cups were considered radiographically loose, of which four were rerevised. Three stems were radiographically loose, of which none was rerevised.Conclusions
IBG is a valuable biological revision technique that may restore bone stock in younger patients. Bone stock reconstruction is important, because these patients likely will outlive their revision implants. Bone reconstruction with impaction grafting may facilitate future revisions.Level of Evidence
Level IV, therapeutic study. 相似文献11.
12.
Wenzel Waldstein Christian Merle Tom Schmidt-Braekling Friedrich Boettner 《International orthopaedics》2014,38(7):1347-1352
Purpose
Limited data exist for the reconstructive potential of short bone-preserving stems in THA using a minimal invasive posterolateral approach. Our study aim was to assess the effect of stem design on the reconstruction of hip offset and leg length in MIS posterolateral THA.Methods
This retrospective consecutive single-surgeon study compares hip offset and leg length, as well as acetabular component positioning (cup anteversion; inclination) of 129 THAs with a cementless standard-length stem (Synergy®) and 143 THAs with a cementless short bone-preserving stem (Trilock®).Results
In reference to the contralateral side, the mean difference in hip offset was 0.9 mm (p = 0.067) for the standard stem and 0.1 mm (p = 0.793) for the short stem, respectively. Leg-length discrepancy was 0.7 mm (Synergy®) and 0.9 mm (Trilock®), respectively. A total of 233 (86 %) acetabular components fell within the target zone for anteversion and inclination.Conclusion
Accurate component positioning in MIS posterolateral approach THA is possible and is not influenced by the type of stem. 相似文献13.
14.
Tsung-Yuan Tsai Dimitris Dimitriou Guoan Li Young-Min Kwon 《International orthopaedics》2014,38(8):1577-1583
Purpose
Component orientations and positions in total hip arthroplasty (THA) are important parameters in restoring hip function. However, measurements using plain radiographs and 2D computed tomography (CT) slices are affected by patient position during imaging. This study used 3D CT to determine whether contemporary THA restores native hip geometry.Methods
Fourteen patients with unilateral THA underwent CT scan for 3D hip reconstruction. Hip models of the nonoperated side were mirrored with the implanted side to quantify the differences in hip geometry between sides.Results
The study demonstrated that combined hip anteversion (sum of acetabular and femoral anteversion) and vertical hip offset significantly increased by 25.3° ± 29.3° (range, −25.7° to 55.9°, p = 0.003) and 4.1 ± 4.7 mm (range, −7.1 to 9.8 mm, p = 0.009) in THAs.Conclusions
These data suggest that hip anatomy is not fully restored following THA compared with the contralateral native hip. 相似文献15.
16.
17.
M. van Heumen P. J. C. Heesterbeek B. A. Swierstra G. G. Van Hellemondt J. H. M. Goosen 《Journal of orthopaedics and traumatology》2015,16(1):15-20
Background
A dual mobility cup has the theoretic potential to improve stability in primary total hip arthroplasty (THA) and mid-term cohort results are favorable. We hypothesized that use of a new-generation dual mobility cup in revision arthroplasty prevents dislocation in patients with a history of recurrent dislocation of the THA.Materials and methods
We performed a retrospective cohort study of patients receiving an isolated acetabular revision with a dual mobility cup for recurrent dislocation of the prosthesis with a minimum follow-up of 1 year. Kaplan–Meier survival analyses were performed with dislocation as a primary endpoint and re-revision for any reason as a secondary endpoint.Results
Forty-nine consecutive patients (50 hips) were included; none of the patients was lost to follow-up. The median follow-up was 29 months (range 12–66 months). Two patients died from unrelated causes. Survival after 56 months was 100 % based on dislocation and 93 % (95 % CI 79–98 %) based on re-revision for any reason. Radiologic analysis revealed no osteolysis or radiolucent lines around the acetabular component during the follow-up period.Conclusion
The dual mobility cup is an efficient solution for instability of THA with a favorable implant survival at 56 months.Level of evidence
Level 4, retrospective case series. 相似文献18.
19.
Patrick Sadoghi Christian Schr?der Andreas Fottner Arnd Steinbrück Oliver Betz Peter E. Müller Volkmar Jansson Andreas H?lzer 《International orthopaedics》2012,36(11):2197-2203