首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 172 毫秒
1.
目的:探讨房间隔缺损(ASD)合并肺动脉瓣狭窄(PS)行介入治疗的临床安全性及其疗效。方法:31例患者,年龄2.5~67(中位年龄31)岁;24例经胸超声心动图(TTE)诊断为ASD合并PS,房间隔缺损最大直径为7~27(16.0±4.8)mm,7例超声心动图术前漏诊ASD,肺动脉瓣狭窄压差35~120(89.8±22.9)mm Hg(1mm Hg=0.133k Pa),所有患者术前行右心室造影检查。先行经皮球囊肺动脉瓣成形术(PBPV),而后置入房间隔缺损封堵器闭合缺损,选择的封堵器直径为12.0~38.0(22.6±5.9)mm。结果:本组28例行PBPV术及ASD介入封堵治疗28均获得成功;其中3例封堵器脱落入主动脉,介入方法取出后,再置入较大封堵器封堵成功,PBPV术后即刻右室收缩压由术前(89.8±22.9)mmHg下降至(39.8±11.3)mm Hg,肺动脉右心室跨瓣压差由术前mm Hg降至(14.8±8.9)mm Hg(P<0.001)。右心室舒张末压由术前(9.9±0.28)mm Hg降至(5.07±0.57)mm Hg(P<0.005),PBPV术后即刻跨瓣压差下降达优良为100%。术后超声心动图随访于术后即刻、1、3及6个月,疗效满意,房间隔未见残余分流。结论:同期介入治疗肺动脉瓣狭窄合并房间隔缺损安全可行,效果良好,但由于合并PS患者,超声心动图术前常常低估或漏诊ASD,因此,需先行肺动脉瓣球囊扩张术后,超声心动图重新复核ASD大小,再行ASD封堵术,必要时分期手术。  相似文献   

2.
目的 :评价经胸壁彩色超声心动图 (TTE)结合球囊测量法引导房间隔缺损 (ASD)经导管封堵术的可靠性及实用价值。方法 :对 6 7例ASD患者 ,采用TTE结合球囊法测量ASD伸展径后 ,分别置入相应型号Am platzer封堵器。 结果 :6 7例患者TTE引导经右心导管封堵ASD术均成功 ,超声测量的ASD最大伸展径与其实际伸展径一致 ,相关系数 (r ) =0 .97,P <0 .0 0 1。 6 4例ASD封堵器一次放置成功 ,3例第 2次放置成功 ;封堵术成功后即刻彩色超声心动图显示 ,穿隔血流消失 ;术后 3个月复查 ,6 6例封堵器位置良好 ,房间隔无分流 ,右心系统明显回缩 ;1例原有两孔缺损的封堵其中的大孔后残留少量分流。结论 :TTE结合球囊测量法引导ASD经右心导管封堵术成功率高、安全和无痛苦 ,值得推广。  相似文献   

3.
目的 探讨彩色超声心动图(TTE)在经胸微创房间隔缺损(ASD)封堵术中的应用价值.方法 对34例ASD患者行经胸微创封堵术,并于术前采用TTE测量各切面ASD长度及周缘情况,术中采用TTE监测封堵过程,术后采用TTE观察心房水平有无残余分流、封堵伞有无脱落及右心系统回缩情况.结果 TTE测量ASD长度为(14.54±7.05)mm,所选封堵器型号大于TTE测量值4~6 mm;33例经胸微创ASD封堵术成功,1例因ASD长度大、一侧无残端组织而无法牢固放置封堵器改开胸手术缝补;术后随访1周、1个月均无残余分流,封堵器封堵牢固、无脱落;右心系统回缩明显.结论 TTE用于经胸微创ASD封堵术能于术前准确测量ASD大小、术中及时监测与引导封堵过程、术后准确观察有无残余分流并评价疗效.  相似文献   

4.
经导管同期治疗复合型先天性心脏病的疗效观察   总被引:12,自引:0,他引:12  
目的研究经导管同期治疗复合型先天性心脏病的策略并评价其疗效。方法34例患者,男12例,女22例。复合类型为:房间隔缺损(ASD)合并肺动脉瓣狭窄(PS)、室间隔缺损(VSD)、动脉导管未闭(PDA)分别是16例、7例、3例,合并二尖瓣狭窄(Lutembacher综合征)2例;VSD合并PDA3例、Taussig-Bing畸形合并PDA1例;2例并发3种畸形(并发ASD、VSD和PDA1例,并发ASD、PS和PDA1例)。经导管介入治疗的原则:先行瓣膜球囊扩张术纠正瓣膜狭窄,其次行VSD封堵术,再次行PDA封堵术,最后行ASD封堵术。术后3d、1个月、6个月分别行经胸超声心动图(TTE)、X线检查评价治疗效果。结果34例复合型先天性心脏病患者均一次性治疗成功。术中未发生任何重要并发症。术后即刻TTE和造影示ASD,VSD,PDA所有封堵器位置良好,无残余分流。16例ASD合并PS者,跨肺动脉瓣平均压差由术前52.6±20.5mmHg下降到术后14.3±9.5mmHg(1mmHg=0.133kPa),差异有统计学意义(P<0.05)。2例Lutembacher综合征患者,超声心动图测量二尖瓣瓣口面积分别由二尖瓣球囊扩张术前1.0和1.2cm2增加到术后1.9和2.0cm2,平均左房压分别由29和26mmHg降至8和7mmHg。对于1例Taussig-Bing畸形合并PDA者,用18mmASD伞成功封堵16mmPDA,降低肺动脉压,改善患者症状,为二次手术创造条件。术后72h、1个月、6个月TTE示所有患者各水平分流均消失,左心房、左心室进行性地缩小,所有封堵器位置固定良好,无移位及脱落;同时行X线检查,肺血均明显减少,房室内径均明显恢复。结论复合型先天性心脏病经导管同期介入治疗虽较单纯型复杂,技术要求相对较高,但如指征掌握恰当,治疗策略合理,操作规范,同样可获得良好的治疗效果。  相似文献   

5.
经胸超声心动图下心导管法修补心房间隔缺损   总被引:8,自引:0,他引:8  
目的 :评价经胸超声心动图 ( TTE)是否可替代食管超声心动图 ( TEE)在经导管修补心房间隔缺损( ASD)术中指导封堵伞的定位。方法 :3 9例适合经导管法修补 ASD的患者入选 ,选用 Amplatzer封堵装置 ,局麻(小儿静脉麻醉 )下 ,在 X线透视和 TTE下进行手术。术后 2 4 h复查 TTE,2 2例术后 3~ 12个月进行了再次随访。结果 :4例未成功包括 2例 ASD实际直径过大 ,1例封堵伞不能到位 ,1例急性心包压塞 ;3 5例封堵成功 ,成功率为 89.7% ;无死亡及栓塞事件发生。3 3例 ( 91.7% )在 TTE指导下完成 ,仅 3例需要 TEE指导 (包括 1例未成功者 )。术后即刻 TTE见 3例存在少许残余分流 ,2 4 h后复查残余分流消失。 2 2例在术后 3~ 12 (平均 5 .5 )个月内复查 TTE,结果示右心房和右心室均有不同程度的缩小 ,平均肺动脉收缩压由术前的〔( 3 8.1± 6.0 ) mm Hg,1m m Hg=0 .13 3 k Pa)〕下降至术后的 ( 2 7.3± 4 .0 ) m m Hg,术前后差异有非常显著性意义 ( P <0 .0 1) ,未见封堵伞移位及新的房水平左向右分流 ,房室瓣功能正常。结论 :90 %以上的 ASD病例可在 TTE指导下完成。 ASD缺损边缘残留组织少 ( 5 m m左右 )或组织菲薄及 ASD直径 >3 4 mm者还应采用 TEE指导手术 ,以免封堵伞位置不良 ,造成术后的移位甚至脱落  相似文献   

6.
目的评价床边超声心动图在房间隔缺损(ASD)封堵术中的临床应用。方法 25例ASD适合介入封堵的病人,术中床边超声心动图测量ASD最大直径,与测量球囊测量ASD直径比较,指导封堵器封堵、释放等过程,并观察有无残余分流及封堵器是否影响周围结构功能。结果 25例患者ASD直径床边超声心动图测量值为(20.52±1.53)mm,球囊导管测量值为(21.41±1.52)mm,二者差异无统计学意义(P>0.05)。25例患者全部一次堵闭成功,术后即刻超声心动图检查无残余分流,各瓣膜无病理性返流或原有返流加重,上、下腔静脉回流正常。结论床边超声心动图在ASD封堵术中能准确估测ASD直径,指导封堵过程,监测有无并发症发生,在ASD封堵术中具有重要指导作用。  相似文献   

7.
目的探讨经胸超声(TTE)和造影测量法指导国产封堵器介入治疗房间隔缺损(ASD)、室间隔缺损(VSD)和动脉导管未闭(PDA)的应用价值。方法术前应用TTE筛选符合封堵适应证的先心病患者50例,其中ASD20例、VSD16例、PDA14例。术中用TTE监测指导释放ASD封堵器;使用造影测量法测量VSD、PDA指导国产封堵器的选择。术后应用TTE定期随访。结果19例ASD、15例VSD、14例PDA封堵成功,总成功率为96.0%(48/50)。封堵失败:1例ASD,缺损最大径36mm;1例VSD,缺损最大径10mmm,为膜周部室缺。结论TTE可用于筛选先心病病例。术中用TTE监测指导释放ASD封堵器,疗效可靠;使用造影测量法测量VSD、PDA指导国产封堵器的选择是手术成功的基本条件之一。  相似文献   

8.
石晶  张军  李军  李利  左健 《心脏杂志》2007,19(5):559-562
目的应用经胸超声心动图(TTE)评价房间隔缺损(ASD)封堵术前、后心脏血流动力学及负荷的变化。方法西京医院ASD封堵术患者30(女23,男7)例,年龄4.563(28±18)岁。于封堵术前、术后3 d、3个月及6个月行TTE检查。测量肺动脉瓣口、三尖瓣口血流速度,左、右心室和心房大小变化。结果ASD封堵术后3 d、3个月、6个月:肺动脉瓣口最大流速、平均流速、速度时间积分以及三尖瓣口E峰和A峰值血流速度较术前显著降低(P<0.01);肺动脉中段内径、右心房和右心室各径较术前显著减小(P<0.01);左心房、左心室各径较术前增大(P<0.05,P<0.01)。术后各个时间点比较各指标也有不同程度改善。结论ASD封堵治疗后患者血流动力学异常和心腔前负荷变化得以纠正。TTE在ASD封堵术后的疗效观察中具有重要的作用。  相似文献   

9.
经导管同期介入治疗复合型先天性心脏病--附2例报道   总被引:1,自引:0,他引:1  
目的:探讨经导管介入治疗在复合型先天性心脏病中的应用。方法:2例患者,术前超声检查分别提示ASD合并VSD和鲁登巴赫综合征(Lutembacher’s syndrome)。ASD均为继发孔型,其延伸直径分别为18 mm与20 mm, VSD为膜周部室缺(PMVSD),直径3.5mm,术前二尖瓣狭窄瓣口面积1.0cm2。分别先行VSD封堵后再行ASD封堵及先行二尖瓣狭窄球囊成形术(PBMV),再行ASD封堵术。结果:2例患者均经导管一次封堵治疗成功。病例一术后出现短时间的室性自主心律、房颤及束支阻滞,经地塞米松治疗后5 d恢复正常。未见有其它严重并发症。结论: 对于复合型先天性心脏病经导管介入治疗技术同样可获得良好的疗效。  相似文献   

10.
目的 :评价经胸超声心动图 (TTE)在术前测量房间隔缺损 (ASD)大小、术中监测与指导儿童ASD封堵的作用。方法 :10例ASD儿童采用TTE多个切面综合判断ASD大小、周缘情况及房间隔伸展径。比较ASD之TTE测值与封堵成功所选用的封堵器大小之间的关系。在封堵术中TTE监测封堵过程、伞释出后牢固程度及彩色多普勒有无分流。结果 :ASD的TTE测值为 8~ 2 4 (15 .8± 5 .9)mm ,封堵器型号为 8~ 2 8(18.8±6 .0 )mm ,TTE测量的ASD大小与封堵器大小相关良好 ,直线方程Y =4 .36 0 +0 .914X ,相关系数r =0 .90 5(P <0 .0 1)。硬缘ASD的封堵器选择比TTE所测ASD大 1~ 5mm ;封堵器型号的选择多在球囊测值的基础上加 0~ 2mm。所有封堵器牢固 ,无脱落。结论 :TTE封堵术前检查和术中指导ASD封堵器的放置是一种可行、有效、简便的方法  相似文献   

11.
Transcatheter closure of atrial septal defects (ASDs) is a safe and effective treatment. Over the past years, an increasing number of elderly patients (age > 60 years) have been admitted for transcatheter closure to prevent ongoing congestive heart failure from volume overload. However, recent data point to the risk of serious acute left ventricular dysfunction leading to pulmonary edema immediately after surgical or transcatheter ASD closure in some patients. In this study, we used a technique described before to recognize in advance patients at risk of left heart failure after ASD closure. Those patients at risk were then treated with preventive conditioning medication for 48-72 hr before definitive transcatheter ASD closure was performed. Fifty-nine patients aged over 60 years (range, 60-81.8 years; median, 68 years) were admitted to our institution for transcatheter closure of an atrial septal defect. All patients received evaluation of atrial pressures before and during temporary balloon occlusion of the ASD. Patients with left ventricular restriction due to increased mean atrial pressures (> 10 mm Hg) during ASD occlusion received anticongestive conditioning medication with i.v. dopamine, milrinone, and furosemide for 48-72 hr before definitive ASD closure with an Amplatzer septal occluder was performed. In 44 patients without any signs of left ventricular restriction, ASD closure was performed within the first session. Fifteen (25%) out of 59 patients showed left ventricular restriction. In the majority of patients with LV restriction, the mean left atrial pressures with occluded ASD were significantly decreased after 48-72 hr of conditioning medication. Definitive ASD closure was then performed in a second session. Only two patients received a fenestrated 32 mm Amplatzer occluder due to persistent increased atrial pressures > 10 mm Hg even after conditioning medication. There were no significant differences in shunt, device size, or defect size between the two groups. Balloon occlusion of atrial septal defects identifies patients with left ventricular restrictive physiology before ASD closure. Intravenous anticongestive conditioning medication seems to be highly effective in preventing congestive heart failure after interventional closure of an ASD in the elderly patient with a restrictive left ventricle.  相似文献   

12.
目的:观察用国产Amplatzer封堵器治疗继发孔型房间隔缺损(ASD)前后心脏结构及血浆心钠肽(ANP)、脑钠肽(BNP)的变化.探讨经导管ASD封堵术的影响。方法:应用超声心动图测量36例ASD患者封堵治疗前、治疗后1d、1月、3月、6月心脏结构参数,并分别测定相应时段血浆心钠肽、脑钠肽的浓度,另选取年龄及性别与之相匹配的健康人36例作为对照组。结果:同术前相比,术后1d、1月、3月、6月,右房、右室内径明显缩小(P〈0.05),而左室舒张末期内径在术后1月、3月明显增大(P〈0.05)。左室收缩末期内径、左房内径及左室射血分数在术前及术后没有明显变化。ASD组ANP、BNP水平在封堵前较对照组明显升高,在封堵1d后开始显著逐渐下降,到6月后基本恢复至正常水平(P均〈0.05)。结论:经导管ASD封堵术减轻了右心的容量负荷.使右房、右室内径明显缩小,也可在短期内改善左室的几何构型,血浆ANP、BNP水平可以作为评价经导管ASD封堵术对心脏容量负荷影响的一项有效指标。  相似文献   

13.
目的介绍成人房间隔缺损(ASD)并发心房颤动(AF)患者的几种治疗方法,并分析其治疗效果。方法:回顾分析本院136例ASD并发有明显临床症状且药物治疗无效的AF病例,其中36例接受介入封堵+经导管射频消融术(导管射频消融组),84例体外循环下ASD补术+改良迷宫术(改良迷宫组),16例单纯介入封堵术(未行经导管射频消融术,单纯介入封堵组),术前,术后12月用心脏超声仪评价右心房、右室内径及肺动脉压力和心电图变化。结果:所有病例的术中、术后均未出现严重并发症,所有病例均无死亡,随访12个月,36例接受介入封堵+经导管射频消融术28例转复为窦性心律,8例仍为AF,后行二次射频消融术转为窦性心律,84例ASD补术+改良迷宫手术患者中有66例转复窦性,14例失败仍为AF,4例为交界性心律,单纯介入封堵组16例8例成功,8例术后仍为AF,与术前比较,各组心脏超声检查示右心房、右心室内径均较术前明显缩小,肺动脉压力明显下降(均P〈0.05)。各组之间无显著差异。经导管射频消融组和改良迷宫手术组AF治愈率高(对比单纯介入组,均P〈0.05),患者心慌不适更能得到改善,生活质量更高。结论:介入封堵及外科手术均能安全有效治疗ASD并发AF,每种方法各有利弊,可依据患者临床具体情况选择。  相似文献   

14.
目的:分析房间隔缺损(ASD)和室间隔缺损(VSD)介入治疗失败后外科手术的效果。方法:选择2000年1月至2007年12月在我院接受经导管介入治疗ASD(12例)和VSD(4例)失败后需再行外科手术的16例,其中封堵器脱落7例,心脏穿孔3例,Ⅲ°房室传导阻滞(AVB)2例,瓣膜关闭不全2例(其中1例合并Ⅲ°-AVB),残余漏和封堵失败各1例。手术均在体外循环下进行,取出封堵器,修复心内畸形,术后入ICU监护。结果:ASD介入治疗患者中,手术探查ASD直径平均31 mm,较术前经彩色多普勒超声心动图诊断的平均直径26 mm增大(P0.05)。ASD部位为中央型5例,下腔型7例,与术前诊断相符率41.7%,不相符率58.3%。VSD直径平均5 mm,与术前差异无统计学意义。VSD部位为膜部2例,流出部与肌部各1例。3例Ⅲ°-AVB患者术后均恢复窦性心律。心内畸形修复完善,无手术死亡。结论:及时采取外科手术治疗介入封堵失败后并发症,效果良好,安全可靠,并可避免并发症造成的不良后果。  相似文献   

15.
Percutaneous closure of an atrial septal defect (ASD) in the elderly with reduced diastolic elasticity of the left ventricle poses a significant management challenge. We report on the case of an 85-year-old patient who was admitted for percutaneous device closure of a moderately large secundum atrial septal defect. Hemodynamic evaluation documented an increase in left atrial pressure from a mean of 12 mm Hg to a mean of 32 mm Hg after balloon test occlusion of the ASD. Two months later, after adequate pretreatment with diuretics and afterload-reducing substances, he underwent successful closure of the ASD using a self-fabricated fenestrated Amplatzer septal occluder, which resulted in a postimplantation left atrial pressure of a mean of 18 mm Hg. Recovery was unremarkable and the fenestration has remained patent for 3 months since implantation of the device. This unique case highlights the feasibility of using a self-fabricated fenestrated Amplatzer septal occluder to close interatrial communications in elderly patients with diastolic dysfunction of the left ventricle.  相似文献   

16.
房间隔缺损封堵术后心功能的变化   总被引:44,自引:1,他引:44  
目的 评价左、右室功能及左房收缩功能在房间隔缺损(ASD)封堵治疗术后及随访中的变化。方法 对成功施行经皮穿刺ASD封堵术的20例患进行研究。所有患于封堵治疗术前、术后及术后3个月行超声心动图检查,左、右室容积采用单平面面积-长度法计算,以左室晚期充盈数作为反映左房收缩功能的指标。结果 ASD填充堵治疗术后,左室舒张末期前后径及及左室舒张末期容积增大,而左室收缩末期容积则未见明显改变,左室每搏量、左室射血分数及短轴缩短率增大。左客观存在偏心率及长径/短径比值均较术前缩小,左室前负荷、收缩功能及几何构型在随访中持续改善。ASD封 堵治疗术后右室舒张末期前后径、右室舒张末期容积、右室收缩末期容积、右室每搏量及右室射血分数(RVEF)均减小;随访中上述指标除RVEF外均进一步减小,而RVEF未见显改变,置入封堵器后及随访左室晚期充盈分数,差异无显性。结论 ASD封堵治疗既减轻了右室的容量铅荷,也改善了左室的收缩功能及几何构型,在短期随访中,左室功能及几何构型持续改善,右室功能维持于正常水平,置入封堵器对左房收缩功能未产生显影响。  相似文献   

17.
目的:介绍老年继发孔型房间隔缺损(ASD)的几种治疗方法,并分析其治疗效果。方法:自2002年1月至2009年6月,我院收治的139例60岁以上的老年继发孔型ASD病例。其中43例行经导管房缺封堵术;21例行微创经胸房缺封堵术;55例行体外循环下房缺修补术;20例因各种原因未行手术,给予药物保守治疗。结果:导管封堵组、经胸封堵组、和手术修补组患者均无死亡。术后远期随访导管封堵组,1例术后第4年死于脑出血。其余2组术后远期随访无死亡。房缺闭合术后心功能较术前明显改善,术后早期复查超声心动图均无残余分流,右心房、右心室明显缩小,肺动脉压力明显降低。保守治疗组,随访病例共有8例死亡。其中4例死于心力衰竭(心衰),1例死于心衰合并尿毒症,1例死于脑出血,1例死于呼吸衰竭,1例死因不详。结论:高龄本身并非老年房间隔缺损手术禁忌,老年患者通过封堵器或手术闭合房缺仍可以重构右心房、右心室,降低肺动脉压,显著改善心功能。3种闭合方法各有优缺点,应根据具体情况选择手术方式。  相似文献   

18.
The impact of an atrial septal defect in the elderly with reduced diastolic elasticity of the left ventricle is unclear. We studied the hemodynamic changes during balloon occlusion of atrial septal defects in patients over 60 years of age. In 18 patients (61-78 years old; median, 70), the left atrial pressure and the mitral valve inflow was measured during complete balloon occlusion of the defect and after deflation of the balloon. In seven patients, the left atrial pressure and the E/A ratio of the mitral valve inflow increased markedly (P = 0.02). Mean atrial pressures reached values of 27 mm Hg and the v-wave peak values of 55 mm Hg. Two patients received a transcatheter device closure and developed congestive heart failure. In the elderly, an atrial septal defect can have a decompressive impact on the left ventricle. Therefore, caution appears to be warranted if atrial septal closure is planned.  相似文献   

19.
目的:分析儿童房间隔缺损(ASD)外科修补术后用药的效果.方法:26例ASD患儿行外科修补治疗,据出院后(手术8d后)用药特点,分为停药组(出院即停药)和服药组(继续服药1个月),观察两组术前、术后4d及3个月临床及超声复查结果,比较其差异.结果:两组患者术后均无左心功能不全等并发症发生,术后4d即有右心室缩小(P<0...  相似文献   

20.
介入治疗先天性心脏病118例近期疗效评价   总被引:2,自引:4,他引:2  
目的:评价应用国产封堵器治疗动脉导管未闭(PDA)、房间隔缺损(ASD)室间隔缺损(VSD)的近期疗效及安全性。方法:118例先天性心脏病患者(PDA24例,ASD48例,VSD46例)均在X线透视及经胸超声心动图监视下经导管置入封堵器治疗PDA、ASD和VSD。结果:全组封堵成功率98.3%,所有封堵成功的患者均于术后24h、7d、1月和3月行经胸超声心动图检查,均无残余分流。结论:经导管置入封堵器是治疗PDA、ASD和VSD的一种操作简便、成功率高、疗效可靠的介入方法。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号