1.
BACKGROUND: We evaluated the improvement in the rate of prostate cancer detection when using a 12-core transperineal biopsy protocol including transitional zone biopsy. METHODS: Between April 2003 and November 2004, 247 consecutive men underwent transperineal systemic 12-core biopsy of the prostate. Six cores were obtained at the peripheral zone, four at the transitional zone and two at the apex. We examined the cancer detection rate in each of the 12 cores, and also determined the improvement of cancer detection resulting from the extensive 12-core versus standard 6-core biopsy. RESULTS: Using the extensive 12-core biopsy, prostate cancer was detected in 98 cases (39.7%). Prostate-specific antigen (PSA), PSA density, the positive rate in digital rectal examination and transrectal ultrasound findings were significantly higher in the prostate cancer group than in the non-prostate cancer group, and prostate volume was larger in non-prostate cancer group. Every site showed almost the same positive rate, between 17.8 and 21.5%. There were 20 cases which were positive in the extended biopsy, but negative in the sextant. The detection improved significantly (20.4%). The improvement of cancer detection in extended biopsy was better in men with PSA levels of 10 ng/mL or less (28.9%), PSA density 0.3 or less (25.8%), negative digital rectal examination (23.3%), and negative transrectal ultrasound (21.6%). Of these twenty patients, no cases with insignificant tumor were detected in the six prostatectomy cases. In particular, three cases of the six were transitional-zone-only cancer. CONCLUSION: Transperineal extended 12-core biopsy including 4 transitional zone cores is a more useful procedure than transperineal 6-core biopsy. Routine transitional zone biopsy, that is different from transrectal biopsy, might be useful for detecting biologically significant cancer.  相似文献   

2.
AIM: To evaluate the diagnostic value of the 10 systematic transrectal ultrasound-guided (TRUS) prostate biopsy compared with the sextant biopsy technique for patients with suspected prostate cancer. Methods: One hundred and fifty-two patients with suspected prostate cancer were included in the study. Patients were entered in the study because they presented with high levels of prostate specific antigen (PSA) (over 4 ng/mL) and/or had undergone an abnormal digital rectal examination (DRE). In addition to sextant prostate biopsy cores, four more biopsies were obtained from the lateral peripheral zone with additional cores from each suspicious area revealed by transrectal ultrasound. Sextant, lateral peripheral zone and suspicious area biopsy cores were submitted separately to the pathological department. Results: Cancer detection rates were 27.6% (42/152) and 19.7% (30/152) for the 10-core and sextant core biopsy protocols, respectively. Adding the lateral peripheral zone (PZ) to the sextant prostate biopsy showed a 28.6% (12/42) increase in the cancer detection rate in patients with positive prostate cancer (P < 0.01). The cancer detection rate in patients who presented with elevated PSA was 29.3% (34/116). When serum PSA was 4-10 ng/mL TRUS-guided biopsy detected cancer in 20.6%, while the detection rate was 32.4% and 47.0% when serum PSA was 10-20 ng/mL and above 20 ng/mL, respectively. Conclusion: The 10 systematic TRUS-guided prostate biopsy improves the detection rate of prostate cancer by 28.6% when compared with the sextant biopsy technique alone, without increase in the morbidity. We therefore recommend the 10-core biopsy protocol to be the preferred method for early detection of prostate cancer.  相似文献   

3.
Aim: To evaluate the best individualized prostate biopsy strategies for Chinese patients with suspected prostate cancer. Methods: The present study included 221 Chinese patients who underwent transrectal ultrasound guided prostate biopsies for the first time. All patients underwent the same 10-core biopsy protocol. In addition to the Hodge sextant technique, four more biopsies were obtained from the base and middle regions of bilateral peripheral zones. The differences between 10-core and sextant strategies in cancer detection among patients with different prostate specific anitgen (PSA) levels were evaluated. The relationship between PSA level, number of positive biopsy cores and organ-confined cancer rate in prostate cancer patients was also analyzed. Results: The overall prostate cancer detection rate was 40.7% in the 221 patients. The 10-core strategy increased cancer detection by 6.67% (6/90) in our patients (P 〈 0.05). The increased cancer detection rates decreased significantly when the patient PSA level increased from 0-20 ng/mL to 20.1-50 ng/mL and 〉 50 ng/mL (P 〈 0.01). The number of positive biopsy cores in prostate cancer patients increased significantly with increasing patient PSA level (P 〈 0.01). The rate of organ-confined prostate cancer decreased significantly with increasing patient PSA level (P 〈 0.01). Conclusion: The extended 10- core strategy is recommended for Chinese patients with PSA 〈 20 ng/mL and the sextant strategy is recommended for those with PSA〉 50 ng/mL. For patients with PSA ranging from 20.1 ng/mL to 50 ng/mL, the 10-core strategy should be applied in patients with life expectancy 〉 10 years and the sextant strategy should be applied in those with life expectancy 〈 10 years. (Asian J Androl 2008 Mar; 10: 325-331)  相似文献   

4.
The aim of this study is to elucidate the diagnostic efficacy between transperineal and transrectal 12-core prostate biopsy for prostate cancer. We prospectively randomized 200 consecutive men into two groups to undergo systematic prostate biopsy. Overall positivity for cancer was similar (47% by transperineal and 53% by transrectal; P=0.480). However, in case with 'gray zone' PSA (from 4.1 to 10.0 ng/ml), significantly more cores were positive when approach was transperineal, especially among transition zone cores. Therefore, urologist preferences are sufficient for choosing an approach, except for a possible small advantage of transperineal biopsy when PSA is in gray zone.  相似文献   

5.
AIM: The optimal biopsy strategy for prostate cancer detection, especially in men with isolated prostate-specific antigen (PSA) elevation, remains to be defined. We evaluated diagnostic yield and safety of transrectal ultrasound (TRUS)-guided transperineal systematic 14-core biopsy and compared the spatial distribution of cancer foci detected with this technique in men with and without abnormality on digital rectal examination (DRE). METHODS: In a prospective study, 289 men aged between 50 and 87 years (median age, 70 years) underwent TRUS-guided transperineal systematic 14-core prostate biopsy because of elevated PSA and/or abnormal DRE findings. Using the fan technique, 12 cores from the peripheral zone and two cores from the transition zone were obtained systematically. To characterize the spatial distribution of cancer positive cores, site-specific overall and unique cancer detection rates were compared between stage T1c and T2 cancers. RESULTS: Prostate cancer was detected in 105 of the 289 patients (36%). Major complications requiring prolonged hospital stay or re-hospitalization during a 4-week postbiopsy period were rare (1.4%). Sixty-seven stage T1c cancers were identified. These cancers were associated with significantly lower PSA and a smaller number of cancer positive cores when compared with stage T2 cancers (n= 38). The overall cancer detection rate was highest at the anterior peripheral zone and the posterior peripheral zone in stage T1c and stage T2 cancers, respectively. The unique cancer detection rate at the anterior peripheral zone was significantly higher in stage T1c cancers than in stage T2 cancers. Therefore, when the prostate is extensively biopsied using the transperineal approach, cancer positive cores are characteristically distributed anteriorly in stage T1c cancers and posteriorly in stage T2 cancers. CONCLUSIONS: TRUS-guided transperineal systematic 14-core biopsy showed an apico-anterior distribution of cancer foci in stage T1c prostate cancers.  相似文献   

6.
AIM: To establish whether extended transrectal (TR) and extended transperineal (TP) biopsies are equivalent in detecting prostate cancer. METHODS: Due to an elevated prostate-specific antigen (PSA) greater than 2.5 ng/mL or abnormal digital rectal examination findings, 783 men underwent a transrectal ultrasound-guided three-dimensional 26-core biopsy, a combination of TR 12-core and TP 14-core biopsies. Using recursive partitioning, the best combination of sampling sites that gave the highest cancer detection rate at a given number of biopsy cores was selected either with a TR or a TP approach. The cancer detection rate and characteristics of detected cancers were compared between the TP 14-core and the TR 12-core biopsies and between selected subset biopsy schemes. RESULTS: Prostate cancer was detected in 283 of the 783 men (36%). There was no statistical difference in cancer detection rate or in the characteristics of detected cancers between TP 14-core and TR 12-core biopsies. As far as the best combination of sampling sites was selected, there was no statistical difference in cancer detection rates or in the characteristics of detected cancers between the TP and the TR subset biopsy schemes up to 12 cores. TP and TR biopsies performed equally, regardless of a history of negative biopsy, a digital rectal examination finding, the PSA level or the prostate volume. CONCLUSIONS: We demonstrated for the first time that extended TP biopsy is as effective as its TR counterpart in detecting cancer and the characteristics of detected cancers, as far as sampling sites are selected to maximize the cancer detection rate.  相似文献   

7.

Introduction:

To increase the detection rate of prostate cancer in recent years, we examined the increase in the number of cores taken at initial prostate biopsy. We hypothesized that an increasing number of cores may undermine the accuracy of models predicting the presence of prostate cancer at initial biopsy in patients submitted to 20-core initial biopsy.

Methods:

A total of 232 consecutive patients with prostate-specific antigen (PSA) between 4 and 20 ng/mL and/or abnormal digital rectal examination (DRE) underwent 12-core prostate biopsy protocol (group 1) or 20-core prostate biopsy protocol (group 2). The patients were divided into subgroups according to the results of their serum PSA and prostate volume. We evaluated the cancer detection rate overall and in each subgroup. Clinical data were analyzed using chi-square analysis and the unpaired t-test or 1-way ANOVA with significance considered at 0.05.

Results:

The 2 groups of patients were not significantly different with regard to parameters (age, abnormal DRE and serum PSA), although median prostate volume in group 1 (57.76 ± 26.94 cc) were slighter greater than in group 2. Cancer detection rate for patients submitted to 20 prostate biopsy was higher than patients submitted to 12 prostate biopsy (35.2% vs. 25%, p = 0.095). Breakdown to PSA level showed a benefit to 20 prostate biopsy for PSA <6 ng/mL (37.1% vs. 12.9%, p = 0.005). Stratifying results by prostate volume, we found that the improvement of cancer detection rate with 20 prostate biopsy was significant in patients with a prostate volume greater than 60 cc (55% in 20 prostate biopsy vs. 11.3% p < 0.05). Morbidity rates were identical in groups 1 and 2 with no statistically significant difference. There appeared to be no greater risk of infection and bleeding with 20 prostate biopsy protocol.

Conclusion:

The 20-core biopsy protocol was more efficient than the 12-core biopsy protocol, especially in patients with prostate specific antigen <6 ng/mL and prostate volume greater than 60 cc.  相似文献   

8.
OBJECTIVES: We compared the detection rates of different transperineal prostate biopsy protocols with the aim to optimize the number of cores to sample according to prostate volume. MATERIAL AND METHODS: From October 2002 to October 2004 we evaluated 480 consecutive patients with PSA between 2.5 and 20 ng/ml undergoing the first set of prostate biopsy. All patients underwent a 14-core TRUS-guided transperineal prostate biopsy, including 12 cores in the peripheral and two in the transitional zone. The detection rate of the 14-core scheme was compared to the one of the other biopsy schemes obtained through the exclusion of pairs of cores. Data were stratified according to the different TRUS estimated prostate volumes. RESULTS: The detection rate of the standard sextant was 35.2%, while those of the 8-core schemes ranged from 37.1 to 38.8%. The 10-core schemes yielded detection rates of 39.6-40.8% and the protocol with 12 biopsies in the peripheral zone diagnosed prostate cancer in 42.1% of the patients. In patients with <30 cc prostate volume, the detection rate of the 14-core scheme was 43.8% and resulted statistically overlapping to the 8-peripheral cores protocol. In patients with 30.1-50 cc prostate volume a 12-peripheral core biopsy reproduced the results of the 14-core sampling. In prostates larger than 50 cc, an even more extensive procedure was mandatory, considering the low detection rate of the 14-core scheme (24.2%). CONCLUSION: Transperineal prostate biopsy is a safe procedure with a very low complication rate and high cancer detection rate. Prostate volume is the most relevant variable in the planning of the optimal number of cores in the extensive first biopsy set. A protocol with more than 8 peripheral cores) is recommended only in patients with prostate volume larger than 30 cc.  相似文献   

9.
PURPOSE: The prostate cancer detection rate in patients with elevated prostate specific antigen (PSA) increases with extended needle biopsy protocols. Transperineal biopsy under transrectal ultrasound guidance is rarely reported, although notable cancer diagnoses are obtained with this technique. We describe the results of 6 and 12 core transperineal biopsy. MATERIALS AND METHODS: A total of 214 patients with PSA greater than 4.0 ng/ml were prospectively randomized to undergo 6 or 12 core transperineal biopsy. Each group of 107 patients was comparable in terms of clinical characteristics. The procedure was performed on an outpatient basis using local anesthesia. Specimens were obtained with a fan technique with 2 puncture sites slightly above the rectum (1 per lobe) under transrectal ultrasound guidance. Cores were taken from all peripheral areas, including the far lateral aspect of the prostate. RESULTS: The overall cancer detection rate was 38% and 51% for 6 and 12 core biopsy, respectively. In patients with PSA between 4.1 and 10 ng/ml the cancer detection rate was 30% and 49% for 6 and 12 core biopsy, respectively. CONCLUSIONS: The 12 core transperineal prostate biopsy is superior to 6 core biopsy. The technique provides optimal prostate cancer diagnosis. About half of the patients with PSA greater than 4.0 ng/ml and a slightly lower percent with PSA between 4.1 and 10 ng/ml have prostate cancer.  相似文献   

10.
The objective of this study is to evaluate the performance of urology residents at each training level in detecting prostate cancer with transrectal ultrasound-guided (TRUS) biopsy. The inclusion criteria were: (1) prostate-specific antigen (PSA) 4-10 ng/ml; and (2) 10-12 cores per biopsy session. Data from repeat biopsy sessions were excluded. Overall prostate cancer detection rate for 170 patients was 39.4%. PSA, digital rectal examination (DRE), and prostate volume were predictors of cancer detection. There were no significant differences in overall cancer detection rates, PSA, DRE, or prostate volume between resident levels. In conclusion, urology residents at all levels of training perform equally well at detecting cancer using TRUS prostate biopsy technology.  相似文献   

11.
BACKGROUND: Using sextant biopsy, 16-41% of prostate cancers were diagnosed on repeat biopsy. The objective of the present study was to compare the differences in the clinical, biochemical and pathological features between patients with positive results on initial and repeat biopsies, with an aim to identify factors that can be used to improve the detection rate of transrectal ultrasound (TRUS) biopsy of the prostate. METHODS: Between February 2000 and April 2001, 222 patients with a mean age of 64 years (range 38-85) underwent TRUS-guided 10-core prostate biopsy for either abnormal prostate specific antigen (PSA) levels (>4 ng/mL) and/or abnormal digital rectal examination (DRE). Of this number, 165 patients underwent their first biopsy, whereas 45 and 12 patients had had one or two previous biopsies, respectively. RESULTS: Prostate cancer detection rates for the initial biopsy group (n = 165), second biopsy group (n = 45) and third biopsy group (n = 12) were 29.7, 23.0 and 41.7%, respectively. Six patients who had a negative first 10-core biopsy underwent a second 10-core biopsy and one patient (16%) was found to have cancer. Apart from total prostate volume, there were no significant statistical differences between the patient age, mean total PSA, PSA density, PSA-transition zone density, DRE and TRUS findings between the initial and repeat biopsy groups of subjects who had cancer. Those who had cancer detected only on repeat biopsies had larger prostate glands (P = 0.041). CONCLUSION: Patients who had cancer detected only on repeat biopsies had bigger prostate glands, supporting the hypothesis that TRUS sextant biopsy as a technique suffers the error of under-sampling in a bigger prostate.  相似文献   

12.
We aimed to evaluate the cancer detection rates of 6-, 10-, 12-core biopsy regimens and the optimal biopsy protocol for prostate cancer diagnosis in patients with renal failure. A total of 122 consecutive patients with renal failure underwent biopsy with age-specific prostate-specific antigen (PSA) levels up to 20?ng/mL. The 12-core biopsy technique (sextant biopsy?+?lateral base, lateral mid-zone, lateral apex, bilaterally) performed to all patients. Pathology results were examined separately for each sextant, 10-core that exclude parasagittal mid-zones from 12-cores (10a), 10-core that exclude apex zones from 12-cores (10b) and 12-core biopsy regimens. Of 122 patients, 37 (30.3%) were positive for prostate cancer. The cancer detection rates for sextant, 10a, 10b and 12 cores were 17.2%, 29%, 23.7% and 30.7%, respectively. Biopsy techniques of 10a, 10b and 12 cores increased the cancer detection rates by 40%, 27.5% and 43.2% among the sextant technique, respectively. Biopsy techniques of 10a and 12 cores increased the cancer detection rates by 17.1% and 21.6% among 10b biopsy technique, respectively. There were no statistical differences between 12 core and 10a core about cancer detection rate. Adding lateral cores to sextant biopsy improves the cancer detection rates. In our study, 12-core biopsy technique increases the cancer detection rate by 5.4% among 10a core but that was not statistically different. On the other hand, 12-core biopsy technique includes all biopsy regimens. We therefore suggest 12-core biopsy or minimum 10-core strategy incorporating six peripheral biopsies with elevated age- specific PSA levels up to 20?ng/mL in patients with renal failure.  相似文献   

13.
Objectives. To investigate the usefulness of digital rectal examination (DRE) and transrectal ultrasonography (TRUS) for prostate cancer diagnosis and to propose a diagnostic algorithm for individual-based cancer screening in subjects with prostate-specific antigen (PSA) levels of 4.0 ng/mL or less.Methods. Between January 1992 and March 2000, 129 subjects with PSA levels of 4.0 or less and abnormal findings on DRE or TRUS underwent prostate biopsy. The subjects were divided into four groups according to the PSA range: 0 to 0.9 ng/mL, 1.0 to 1.9 ng/mL, 2.0 to 2.9 ng/mL, and 3.0 to 4.0 ng/mL. The reliability of the DRE and TRUS and the clinicopathologic features of prostate cancer were investigated among these four groups.Results. Of the 129 subjects, 17 (13.2%) patients with prostate cancer were diagnosed. The detection rate was 2.2% (1 of 45), 0% (0 of 27), 20.6% (7 of 34), and 39.1% (9 of 23) in subjects with PSA levels of less than 1.0 ng/mL, 1.0 to 1.9 ng/mL, 2.0 to 2.9 ng/mL, and 3.0 to 4.0 ng/mL, respectively. The proportion of patients with Stage II, III, and IV was 58.8%, 41.2%, and 0%, respectively. The percentage with Gleason scores of 8 to 10 was 17.6%. The detection rate of abnormal findings on DRE and TRUS was 14.4% (13 of 90) and 9.5% (7 of 74), respectively. Adding TRUS to DRE in the screening program of subjects with PSA levels of 2.0 to 4.0 ng/mL, increased the detection rate of prostate cancer to 30.8% (4 of 13).Conclusions. Routine prostate biopsy should not be undertaken except for highly suspicious DRE findings in subjects with PSA levels less than 2.0 ng/mL. The additional use of TRUS in subjects with PSA levels of 2.0 to 4.0 ng/mL would improve the sensitivity of prostate cancer detection. The diagnostic algorithm proposed in the present study is useful as a screening method for prostate cancer in subjects with PSA levels of 4.0 ng/mL or less.  相似文献   

14.
PURPOSE: Prostate cancer detection on standard sextant biopsy is considered inadequate. Various biopsy protocols have been introduced to improve cancer diagnosis. We report our experience with transperineal 12-core prostate biopsy. MATERIALS AND METHODS: In a prospective study 650 patients underwent prostate specific antigen (PSA) measurement during a 15-month period, of whom 141 with PSA greater than 4 ng./ml. also underwent transperineal 12-core prostate biopsy using the fan technique. Median PSA was 8 ng./ml. (range 4.1 to 5,000). RESULTS: Prostate cancer was detected in 72 of the 141 patients (51%), including 44 of the 97 (45%) with PSA between 4.1 and 10 ng./ml. This incidence is higher than previously reported in the literature using other biopsy techniques. Disease was low grade Gleason 2 to 4 in 4 cases (5%), intermediate grade Gleason 5 to 6 in 26 (35%) and high grade Gleason 7 to 10 in the remaining 42 (60%). CONCLUSIONS: A high cancer detection rate is achieved by 12-core transperineal prostate biopsy. Most tumors represent clinically significant cancer. Further randomized trials are required to confirm these data.  相似文献   

15.
Kawakami S  Okuno T  Yonese J  Igari T  Arai G  Fujii Y  Kageyama Y  Fukui I  Kihara K 《European urology》2007,51(3):675-82; discussion 682-3
OBJECTIVES: To explore an optimal combination of sampling sites to detect prostate cancer in a repeat biopsy setting. METHODS: A transrectal ultrasound-guided systematic three-dimensional 26-core biopsy (3D26PBx), a combination of transrectal 12 and transperineal 14 core biopsies, was performed in 235 Japanese men with prior negative biopsy. Using recursive partitioning, we evaluated cancer detection of all possible combinations of sampling sites and selected the combination that provides the highest cancer detection rate at a given number of biopsy cores. RESULTS: Prostate cancer was detected in 87 of the 235 (37%) men. The 3D26PBx improved cancer detection by 89% relative to the conventional transrectal sextant biopsy. Neither Gleason score nor percentage of Gleason 4/5 cancers differed between cancers with and without positive cores within the transrectal sextant-sampling sites. A three-dimensional combination of transrectal and transperineal approaches outperformed either transrectal or transperineal approach alone. Recursive partitioning revealed that a three-dimensional 16-core (transrectal eight cores plus transperineal eight cores) biopsy could detect all the cancers with the minimum number of cores. CONCLUSIONS: We propose a three-dimensional combination of transrectal eight cores taken from the far lateral peripheral zone and the parasagittal base, and transperineal eight cores taken from the anterior and posterior apex and the transition zone as an optimal set of sampling sites for repeat biopsy.  相似文献   

16.
Background :
The objectives of this study were to compare the efficacy of 3 modalities (prostate-specific antigen (PSA) assay, digital rectal examination (DRE), and transrectal ultrasonography (TRUS)) in detecting prostate cancer which was pathologically confirmed by TRUS-guided systematic six-sextant biopsy, and to investigate the relationship between the number of positive cores and several clinicopathological parameters.
Methods :
Between 1 992 and 1994, 297 males (155 from a mass screening program and 142 identified as outpatients) with a mean age of 71 years, underwent examinations including PSA determination, DRE, TRUS and systematic six-sextant biopsy, and/or additional directed biopsy.
Results :
Prostate cancer was detected in 93 men. The sensitivity level of the PSA assay was significantly higher (85%) than that of either DRE or TRUS. Patients with an abnormal DRE or TRUS, elevated PSA levels, and those in the T3-T4 category or with moderate to poorly-differentiated adenocarcinomas had more positive biopsy cores (P< 0.05). Also, the relationships of both the number of positive biopsy cores and tumor grade to bone metastasis were significant (P < 0.01). Of 209 hypoechoic areas identified by transrectal ultrasonography, 42% were cancerous, and of 427 isoechoic areas, 1 2% were cancerous. The percentage of positive biopsy cores with hypoechoic areas was 86% in the subjects with a PSA > 10 ng/mL, but low (9%) in subjects with a PSA < 4 ng/mL, and the percentage of negative biopsy cores with a normal TRUS was high (98%) in subjects with a PSA of < 4 ng/mL, but lower (67%) in subjects with a PSA > 10 ng/mL.
Conclusion :
The serum PSA assay was more useful than either DRE or TRUS in detecting prostate cancer. The percentage of bone metastasis increased concomitant with the number of positive biopsy cores, and the positive biopsy rate of hypoechoic areas positively correlated with the PSA level.  相似文献   

17.
前列腺体积及前列腺穿刺针数对前列腺癌诊断的影响   总被引:1,自引:0,他引:1  
目的探讨前列腺体积及前列腺穿刺针数对前列腺癌诊断情况的影响并分析其原因。方法回顾性总结2002∽2009年间于我院行超声引导下经直肠前列腺系统12针穿刺292例患者的临床资料。患者PSA在o~20ng/mL之间。经直肠超声计算前列腺体积。将患者按照前列腺体积分为:〈30mL,30∽60mL,60∽90mL,〉90mL四组,比较各组前列腺穿刺6针、8针、10针、12针时前列腺癌诊断率。统计学Fisher’S检验比较各组间差异性。结果总体前列腺癌诊断率为25%(73/292),在〈30mL组:6针、8针、10针、12针的前列腺癌诊断率相同,均为39.13%(21/54);在30~60mL组:6针、8针、10针、12针的诊断率分别为:21.3%(23/108)、23.1%(25/108)、23.1%(25/108)、24.1%(26/108),诊断率无显著差异(P〉0.05)。在60~90mL组:6针的诊断率为12.9%(12/93),显著低于8针(19.4%(18/93)3、10针[20.4%(19/93)]、12针(20.4%(19/93)]的诊断率(Pd0.05)。在〉90mL组:6针、8针的诊断率均为8.1%(3/37),显著低于10针、12针的诊断率C18.9%(7/37),P〈0.053。黠论前列腺体积是选择前列腺穿刺针数时的一个重要的参考因素,在前列腺体积较大的情况下,可适当的增加前列腺穿刺针数,在前列腺体积较小的情况下,增加前列腺穿刺针数并不能提高前列腺癌的诊断率。  相似文献   

18.
目的:分析单中心超声引导下12+x针前列腺穿刺活检结果,比较不同穿刺途径的临床效果。方法:回顾分析2016年6月~2019年12月我院完成的407例前列腺穿刺活检的临床资料,经直肠前列腺穿刺290例(经直肠组),经会阴前列腺穿刺117例(经会阴组),均采用超声引导下12+x针法,前列腺影像学正常者行系统穿刺,影像学异常者行系统+靶向穿刺。比较两组前列腺癌(PCa)的检出率及并发症差异,分析两组按PSA、影像学分层PCa检出率的差异,比较靶向穿刺与系统穿刺癌检出率的差异,分析临床有意义前列腺癌(csPCa)的检出情况。结果:(1)PCa总检出率为44.0%(179/407),经直肠组与经会阴组PCa检出率比较差异无统计学意义[44.8%(130/290)vs.41.9%(49/117),P>0.05]。其中,PSA≤4 ng/mL、4 ng/mL20 ng/mL各水平分层中,两组PCa检出率比较差异无统计学意义(P>0.05)。两组中前列腺影像学异常者的PCa检出率均高于影像学正常者(P<0.05)。影像学异常者中,经直肠组与经会阴组PCa检出率比较差异无统计学意义(P>0.05)。(2)前列腺影像学异常者总的PCa检出率为57.5%(111/193),靶向穿刺PCa检出率为42.0%(81/193),系统穿刺为47.7%(92/193),两者比较差异无统计学意义(P>0.05),但靶向穿刺单针阳性率比系统穿刺更高(P<0.01)。同一途径下的靶向穿刺与系统穿刺PCa检出率比较差异无统计学意义(P>0.05)。两组中分别比较靶向穿刺、系统穿刺的PCa检出率,差异均无统计学意义(P>0.05)。(3)在所有患者中,经直肠途径csPCa检出率为36.9%(107/290),经会阴途径csPCa检出率为40.2%(47/117),两者比较差异无统计学意义(P>0.05)。靶向穿刺与系统穿刺在csPCa的检出率上比较差异无统计学意义。csPCa在诊断出的PCa患者中的占比,经会阴途径占比高于经直肠途径[95.9%(47/49)vs.82.3%(107/130),P<0.05]。(4)经直肠组总并发症发生率显著高于经会阴组[39.3%(114/290)vs.20.5%(24/117),P<0.01]。经直肠组发热、血便发生率比经会阴组更高,分别为[10.3%(30/290)vs.3.4%(4/117),P<0.05]、[14.1%(41/290)vs.1.7%(2/117),P<0.01],两组在血尿、下尿路症状、尿潴留、迷走反射发生率上比较差异均无统计学意义(P>0.05)。结论:超声引导下12+x针前列腺穿刺活检PCa检出率较好,影像学异常者靶向穿刺与系统穿刺PCa、csPCa检出率差异均无统计学意义,靶向穿刺单针阳性率较高。经直肠途径与经会阴途径在PCa、csPCa检出率比较差异无统计学意义,经会阴途径并发症更少。在诊断出的PCa中,经会阴途径可检出更多的csPCa。  相似文献   

19.
PURPOSE: Several studies suggest that sextant transrectal ultrasound guided biopsy of the prostate provides insufficient material to detect all clinically important prostate cancer, and obtaining more biopsy cores may improve the cancer detection rate. We performed a prospective randomized trial comparing 6 to 12 prostate biopsy cores to determine the impact on the cancer detection rate. MATERIALS AND METHODS: We prospectively randomized 244 men, including 71 (29%) black men, with a mean age plus or minus standard deviation of 65 +/- 8 years to undergo biopsy with 6 or 12 peripheral zone tissue cores. In our study subjects serum total prostate specific antigen (PSA) was between 2.5 and 20 ng./ml., and/or digital rectal examination was suspicious for cancer. All men completed a self-administered pre-biopsy and 2 post-biopsy questionnaires at 2 and 4 weeks. Cancer detection rates were compared in the groups and correlated with race, biopsy history, digital rectal examination findings, total PSA, transrectal ultrasound volume and PSA density, as determined by the formula, total PSA/transrectal ultrasound volume. RESULTS: The cancer detection rate in the 6 and 12 core groups was almost identical (26% and 27%, p = 0.9). There was no significant difference in cancer detection in the 2 trial arms with respect to subject race, biopsy history, digital rectal examination findings, total PSA, transrectal ultrasound volume or PSA density. However, our study did not have the statistical power to rule out small differences. CONCLUSIONS: The overall cancer detection rate is not materially increased by 12 core, peripheral zone biopsy in men in whom prostate cancer was mainly detected by screening.  相似文献   

20.
目的:探讨超声引导下经会阴前列腺24针饱和穿刺活检与14针穿刺活检方案对PSA<20μg/L可疑前列腺癌患者的筛检阳性率及其相关并发症。方法:选取116例可疑前列腺癌患者行经会阴超声引导下14针穿刺活检(14针组),另136例患者,行经会阴24针饱和前列腺穿刺活检(24针饱和组),比较两组前列腺癌筛检阳性率、标本阳性率及穿刺后肉眼血尿、泌尿系感染、尿潴留等并发症的发生率。结果:两组患者平均年龄、穿刺前PSA水平、平均前列腺体积等指标均无统计学差异(P>0.05)。24针饱和组及14针组前列腺癌筛检总体阳性率分别为48.53%和17.24%,存在显著性差异(P<0.001),标本阳性率分别为8.09%和2.83%(P=0.012);其中24针饱和组前列腺尖部肿瘤的检出率(11.76%)显著高于14针组(1.72%,P<0.05)。两组穿刺后尿潴留、泌尿系感染和肉眼血尿等发生率均无统计学差异(P>0.05)。结论:24针经会阴前列腺饱和穿刺活检方法显著提高PSA<20μg/L患者中前列腺癌的筛检阳性率,尤其是增加了前列腺尖部区域的肿瘤筛检阳性率,而并未增加相关并发症。  相似文献   