首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Nerve conduits enhance nerve regeneration in the repair of long-distance peripheral nerve defects. To help optimize the effectiveness of nerve conduits for nerve repair, we developed a multi-step electrospinning process for constructing nerve guide conduits with aligned nanofibers. The alignment of the nerve guide conduits was characterized by scanning electron microscopy and fast Fourier transform. The mechanical performance of the nerve guide conduits was assessed by testing for tensile strength and compression resistance. The biological performance of the aligned fibers was examined using Schwann cells, PC12 cells and dorsal root ganglia in vitro. Immunohistochemistry was performed for the Schwann cell marker S100 and for the neurofilament protein NF200 in PC12 cells and dorsal root ganglia. In the in vivo experiment, a 1.5-cm defect model of the right sciatic nerve in adult female Sprague-Dawley rats was produced and bridged with an aligned nerve guide conduit. Hematoxylin-eosin staining and immunohistochemistry were used to observe the expression of ATF3 and cleaved caspase-3 in the regenerating matrix. The recovery of motor function was evaluated using the static sciatic nerve index. The number of myelinated fibers, axon diameter, fiber diameter, and myelin thickness in the distal nerve were observed by electron microscopy. Gastrocnemius muscle mass ratio was also determined. The analyses revealed that aligned nanofiber nerve guide conduits have good mechanical properties and can induce Schwann cells, PC12 cells and dorsal root ganglia to aggregate along the length of the nanofibers, and promote the growth of longer axons in the latter two(neuronal) cell types. The aligned fiber nerve conduits increased the expression of ATF3 and cleaved caspase-3 at the middle of the regenerative matrix and at the distal nerve segment, improved sciatic nerve function, increased muscle mass of the gastrocnemius muscle, and enhanced recovery of distal nerve ultrastructure. Collectively, the results show that highly aligned nanofibers improve the performance of the nerve conduit bridge, and enhance its effectiveness in repairing peripheral nerve defects.  相似文献   

2.
This paper describes a novel biodegradable conduit that provides a combination of physical, chemical and biological cues at the cellular level to facilitate peripheral nerve regeneration. The conduit consists of a porous poly(D,L-lactic acid) (PDLLA) tubular support structure with a micropatterned inner lumen. Schwann cells were pre-seeded into the lumen to provide additional trophic support. Conduits with micropatterned inner lumens pre-seeded with Schwann cells (MS) were fabricated and compared with three types of conduits used as controls: M (conduits with micropatterned inner lumens without pre-seeded Schwann cells), NS (conduits without micropatterned inner lumens pre-seeded with Schwann cells) and N (conduits without micropatterned inner lumens, without pre-seeded Schwann cells). The conduits were implanted in rats with 1 cm sciatic nerve transections and the regeneration and functional recovery were compared in the four different cases. The number or size of regenerated axons did not vary significantly among the different conduits. The time of recovery, and the sciatic function index, however, were significantly enhanced using the MS conduits, based on qualitative observations as well as quantitative measurements using walking track analysis. This demonstrates that biodegradable micropatterned conduits pre-seeded with Schwann cells that provide a combination of physical, chemical and biological guidance cues for regenerating axons at the cellular level offer a better alternative for repairing sciatic nerve transactions than conventional biodegradable conduits.  相似文献   

3.
Although the peripheral nervous system has an intrinsic ability for repair and regeneration after injury, bridging long peripheral nerve defects remains a challenge. Functional nerve regeneration depends on interactions among axons, Schwann cells, fibroblasts and immune cells. Macrophages, as immune cells recruited early in this process, show polarization toward phenotypes that are detrimental or beneficial to tissue remodeling depending on the microenvironment of the scaffolds. In this study, we investigated the effects of macrophage phenotypes modulated by collagen VI on axonal regeneration and functional recovery by bridging a 15‐mm‐long sciatic nerve defect in rats. Our results showed that local delivery of collagen VI within a polycaprolactone (PCL) electrospun conduit increased the recruitment of macrophages and their polarization toward the pro‐healing (M2) phenotype. In addition, the axonal regeneration and neurologic functional recovery in the PCL/collagen VI conduit group are equivalent to that of an autograft. In conclusion, the present study confirmed that PCL/collagen VI conduits with sustained release of collagen VI in the local microenvironment may, through triggering macrophage M2 polarization to enhance the nerve regeneration, suggest that our combined biomaterial‐immunomodulatory system may be an attractive candidate for peripheral nerve regeneration.  相似文献   

4.
Transplantation of allogeneic Schwann cells (SC) would make it feasible to reconstruct immediately peripheral nerve defects, compared to using autologous SC; however, this treatment modality has not been adequately evaluated. The aim of this study was to characterize and compare the effects of allogeneic versus syngeneic SC transplantation following peripheral nerve injury. Polyhydroxybutyrate conduits were used to bridge a 10-mm gap in the rat sciatic nerve. The conduits were filled with alginate hydrogel with or without cultured allogeneic or syngeneic genetically labeled SC, without the use of immunosuppressive therapy, and examined after 2, 3, and 6 weeks with 5-bromo-4-chloro-3-indoyl-beta-D-galactosidase chemical staining and immunohistochemistry to quantify SC migration into the conduit, axonal regeneration, the state of SC differentiation, and the expression of major histocompatibility complexes (MHC) I and II, as well as to quantify macrophage and B- and T-lymphocyte infiltration. Allogeneic SC were rejected by 6 weeks, whereas syngeneic SC could still be identified. Allogeneic and syngeneic SC equally enhanced the axonal regeneration distance but the quantity of axons was greater using syngeneic SC. The ingrowth of SC into the conduits containing allogeneic SC was similar to that observed in the presence of syngeneic SC, indicating the absence of deleterious immune response. SC continued to express phenotypic markers of nonmyelination and these were highest in conduits with allogeneic SC. Expression of MHC I and II was higher in the conduits with allogeneic SC at 3 weeks and without significant difference in the number of macrophages and lymphocytes, except at 6 weeks, when there was a larger number of lymphocytes using syngeneic SC. In conclusion, allogeneic SC enhanced axonal regeneration distance and did not induce a deleterious immune response. In a clinical setting the immediate availability of allogeneic SC for transplantation may compensate for the better outcome achieved by the use of autologous SC that require a longer preparation time in culture.  相似文献   

5.
Using RT-PCR, we have investigated expression of isoforms beta1 (the axonal isoform) and alpha2a-2b (the mesenchymal isoform) of neuregulin-1, one of the most important known trophic factors for Schwann cells, in the rat sciatic nerve repaired by muscle-enriched non-nervous conduits (made by a vein filled with fresh skeletal muscle). Repaired nerves were harvested 2, 6 and 13 days post-operatively. Results showed that while muscle-vein combined grafts were enriched in mRNA coding for alpha2a-2b since the very early regeneration stages, isoform beta1 mRNA was not detectable inside the tubes at day 2 and 6 post-operatively while its expression at day 13 was very slight. These results suggest that Schwann cell survival and activity inside a fresh muscle-enriched non-nervous conduit graft (a key factor for successful nerve regeneration along the graft) may be supported by the mesenchymal isoform of neuregulin-1 during very early repair phases, i.e. when axons are still not present along the tube.  相似文献   

6.
7.
Hu J  Zhu QT  Liu XL  Xu YB  Zhu JK 《Experimental neurology》2007,204(2):658-666
Despite intensive efforts in the field of peripheral nerve injury and regeneration, it remains difficult in humans to achieve full functional recovery following extended peripheral nerve lesions. Optimizing repair of peripheral nerve injuries has been hindered by the lack of viable and reliable biologic or artificial nerve conduits for bridging extended gaps. In this study, we utilized chemically extracted acellular allogenic nerve segments implanted with autologous non-hematopoietic mesenchymal stem cells (MSCs) to repair a 40 mm defect in the rhesus monkey ulnar nerve. We found that severely damaged ulnar nerves were structurally and functionally repaired within 6 months following placement of the MSC seeded allografts in all animals studied (6 of 6, 100%). Furthermore, recovery with the MSC seeded allografts was similar to that observed with Schwann cell seeded allografts and autologous nerve grafts. The findings presented here are the first demonstration of the successful use of autologous MSCs, expanded in culture and implanted in a biological conduit, to repair a peripheral nerve gap in primates. Given the difficulty in isolating and purifying sufficient quantities of Schwann cells for peripheral nerve regeneration, the use of MSCs to seed acellular allogenic nerve grafts may prove to be a novel and promising therapeutic approach for repairing severe peripheral nerve injuries in humans.  相似文献   

8.
Peripheral nerve injuries occur as the result of sudden trauma and lead to reduced quality of life.The peripheral nervous system has an inherent capability to regenerate axons.However,peripheral nerve regeneration following injury is generally slow and incomplete that results in poor functional outcomes such as muscle atrophy.Although conventional surgical procedures for peripheral nerve injuries present many benefits,there are still several limitations including scarring,difficult accessibility to donor nerve,neuroma formation and a need to sacrifice the autologous nerve.For many years,other therapeutic approaches for peripheral nerve injuries have been explored,the most notable being the replacement of Schwann cells,the glial cells responsible for clearing out debris from the site of injury.Introducing cultured Schwann cells to the injured sites showed great benefits in promoting axonal regeneration and functional recovery.However,there are limited sources of Schwann cells for extraction and difficulties in culturing Schwann cells in vitro.Therefore,novel therapeutic avenues that offer maximum benefits for the treatment of peripheral nerve injuries should be investigated.This review focused on strategies using mesenchymal stem cells to promote peripheral nerve regeneration including exosomes of mesenchymal stem cells,nerve engineering using the nerve guidance conduits containing mesenchymal stem cells,and genetically engineered mesenchymal stem cells.We present the current progress of mesenchymal stem cell treatment of peripheral nerve injuries.  相似文献   

9.
Mesenchymal stem cells (MSCs) support axon regeneration across artificial nerve bridges but their differentiative capacity and ability to promote nerve regeneration remains unclear. In this study, MSCs isolated from bone marrow of Sprague–Dawley rats were characterized by plastic adherence and pluripotency towards mesodermal lineages. Isolated undifferentiated MSCs (uMSCs) were stimulated towards a Schwann cell (SC) phenotype using specific growth factors, and cell marker analysis was performed to verify SC phenotype in vitro. Differentiation resulted in temporally dependent positive immunocytochemical staining for the SC markers, glial fibrillary acidic protein (GFAP), S100, and nerve growth factor receptor (NGFR), with maximal marker expression achieved after 6 days of treatment with differentiation media. Quantitative analysis demonstrated that ~ 50% of differentiated MSCs (dMSCs) have a SC phenotype. Using an indirect co-culture system, we compared the ability of dorsal root ganglion (DRG) cells to extend neurites in indirect contact with uMSCs and dMSCs as compared to SCs. The mean values of the longest length of the DRG neurites were the same for the dMSCs and SCs and significantly higher than the uMSC and DRG mono-culture systems (p < 0.05). In vivo, compared to an empty conduit, dMSC seeded collagen nerve conduits resulted in a greater number of sciatic motoneurons regenerating axons through the conduit into the distal nerve stump. We conclude that bone marrow-derived MSCs differentiate into a SC-phenotype that expresses SC markers transiently and sufficiently to support limited neurite outgrowth in vitro and axonal regeneration equivalent to that of SCs in vitro and in vivo. The nerve autograft remains the most effective conduit for supporting regeneration across nerve gaps.  相似文献   

10.
聚乳酸聚羟基乙酸共聚物三维神经导管修复周围神经缺损   总被引:1,自引:0,他引:1  
背景:异体神经移植由于存在难以消除的宿主免疫排斥反应,限制了其使用,许多学者试图用其他组织替代来弥补以上不足,但效果均不满意。目前,尚没有研制出公认的效果满意的人工神经,自体神经移植至今仍被认为是最佳选择。 目的:观察聚乳酸聚羟基乙酸共聚物(PLGA,85∶15)三维神经导管修复大鼠周围神经缺损的可行性,及神经导管内微丝支架的作用和不同数量微丝对神经再生的影响。 方法:40只成年SD大鼠随机数字表法分为4组,制作大鼠12 mm的左侧坐骨神经缺损模型,用该导管桥接大鼠12 mm的坐骨神经缺损。A组:PLGA神经导管组;B组:PLGA神经导管内纵形放入20根PLGA微丝;C组:PLGA神经导管内纵形放入40根PLGA微丝;D组:自体神经移植组。A、B、C组神经导管内均注入层粘蛋白+神经生长因子混合液。造模后动态观察大鼠肌肉萎缩、跛行情况,测量神经导管内再生神经的传导速度、小腿三头肌湿质量恢复率。对再生神经中1/3段行组织学观察及图像分析以评价神经修复的效果。 结果与结论:造模后各组再生神经均已通过神经导管长入远端,B、D组再生神经较A、C组粗大;再生神经的运动神经传导速度B组和D组明显快于A组和C组(P < 0.05);A组、C组肌肉萎缩最明显,而B组、D组肌肉萎缩较轻且肌肉萎缩程度基本相当。病理图像分析神经纤维计数以D组最多,B组次之,而与A组、C组相比差异均有显著性意义(P < 0.05),B组与D组的再生神经纤维数量及成熟程度均要明显优于A组和C组。提示新型的PLGA三维神经导管能有效引导SD大鼠坐骨神经长过12 mm的神经缺损,是一种较理想的神经导管;神经导管内微丝支架能有效引导神经再生,数量过多反而可能抑制神经再生。  相似文献   

11.
There are receptors on denervated Schwann cells that may respond to the neurotransmitters that are released from growth cones of regenerating motor axons. In order to ascertain whether the interaction of the transmitters and their receptors plays a role during axon regeneration, we investigated whether pharmacological block of the interaction would reduce the number of motoneurons that regenerate their axons after nerve section and surgical repair. Peripheral nerves in the hindlimbs of rats and mice were cut and repaired, and various drugs were applied to the peripheral nerve stump either directly or via mini-osmotic pumps over a 2–4-week period to block the binding of acetylcholine to nicotinic and muscarinic acetylcholine receptors (AChRs: α-bungarotoxin, tubocurarine, atropine and, gallamine) and binding of ATP to P2Y receptors (suramin). In rats, the nicotinic AChR antagonistic drugs and suramin reduced the number of motoneurons that regenerated their axons through the distal nerve stump. In mice, suramin significantly reduced the upregulation of the carbohydrate HNK-1 on the Schwann cells in the distal nerve stump that normally occurs during motor axon regeneration. These data indicate that chemical communication between regenerating axons and Schwann cells during axon regeneration via released neurotransmitters and their receptors may play an important role in axon regeneration.  相似文献   

12.
Given the anatomic complexity at the bifurcation point of a nerve trunk, enforced suturing between stumps can lead to misdirection of nerve axons, thereby resulting in adverse consequences. We assumed that Y-tube conduits injected with human umbilical cord stem cells could be an effective method to solve such problems, but studies focused on the best type of Y-tube conduit remain controversial. There-fore, the present study evaluated the applicability and efifcacy of various types of Y-tube conduits containing human umbilical cord stem cells for treating rat femoral nerve defects on their bifurcation points. At 12 weeks after the bridging surgery that included treatment with different types of Y-tube conduits, there were no differences in quadriceps femoris muscle weight or femoral nerve ultrastructure. However, the Y-tube conduit group with longer branches and a short trunk resulted in a better outcome according to retrograde labeling and electro-physiological analysis. It can be concluded from the study that repairing a mixed nerve defect at its bifurcation point with Y-tube conduits, in particular those with long branches and a short trunk, is effective and results in good outcomes.  相似文献   

13.
Skeletal muscle-derived cells have strong secretory function,while skeletal muscle-derived stem cells,which are included in muscle-derived cells,can differentiate into Schwann cell-like cells and other cell types.However,the effect of muscle-derived cells on peripheral nerve defects has not been reported.In this study,5-mm-long nerve defects were created in the right sciatic nerves of mice to construct a peripheral nerve defect model.Adult female C57BL/6 mice were randomly divided into four groups.For the muscle-derived cell group,muscle-derived cells were injected into the catheter after the cut nerve ends were bridged with a polyurethane catheter.For external oblique muscle-fabricated nerve conduit and polyurethane groups,an external oblique muscle-fabricated nerve conduit or polyurethane catheter was used to bridge the cut nerve ends,respectively.For the sham group,the sciatic nerves on the right side were separated but not excised.At 8 and 12 weeks post-surgery,distributions of axons and myelin sheaths were observed,and the nerve diameter was calculated using immunofluorescence staining.The number,diameter,and thickness of myelinated nerve fibers were detected by toluidine blue staining and transmission electron microscopy.Muscle fiber area ratios were calculated by Masson’s trichrome staining of gastrocnemius muscle sections.Sciatic functional index was recorded using walking footprint analysis at 4,8,and 12 weeks after operation.The results showed that,at 8 and 12 weeks after surgery,myelin sheaths and axons of regenerating nerves were evenly distributed in the muscle-derived cell group.The number,diameter,and myelin sheath thickness of myelinated nerve fibers,as well as gastrocnemius muscle wet weight and muscle area ratio,were significantly higher in the muscle-derived cell group compared with the polyurethane group.At 4,8,and 12 weeks post-surgery,sciatic functional index was notably increased in the muscle-derived cell group compared with the polyurethane group.These criteria of the muscle-derived cell group were not significantly different from the external oblique muscle-fabricated nerve conduit group.Collectively,these data suggest that muscle-derived cells effectively accelerated peripheral nerve regeneration.This study was approved by the Animal Ethics Committee of Plastic Surgery Hospital,Chinese Academy of Medical Sciences(approval No.040)on September 28,2016.  相似文献   

14.
Adipose tissue is a good source for isolation of cells with stem-cell-like properties. The effects of undifferentiated cultured bone marrow stromal cells (BMSCs) and omental adipose-derived nucleated cells (OADNCs) on peripheral nerve regeneration were compared in a rat nerve regeneration model. A 10-mm sciatic nerve defect was bridged using a vein graft. In one group, the vein was filled with BMSCs and in the other group with OADNCs. Functional study, morphometric indices, and immunohistochemistry indicated there was no significant difference (P > 0.05) between groups in recovery of regenerated axons at 4, 8, and 12 weeks after surgery. OADNCs enhanced regeneration similar to undifferentiated BMSCs. These observations suggest OADNCs represent an effective and cost-saving cell population due to the shortened time interval from tissue collection to cell injection as well as procedural simplicity. This approach is clinically translatable toward new methods for enhanced peripheral nerve repair without the limitations of BMSC.  相似文献   

15.
The clinical effects of 2-mm small gap sleeve bridging of the biological conduit to repair peripheral nerve injury are better than in the traditional epineurium suture, so it is possible to replace the epineurium suture in the treatment of peripheral nerve injury. This study sought to identify the regeneration law of nerve fibers in the biological conduit. A nerve regeneration chamber was constructed in models of sciatic nerve injury using 2-mm small gap sleeve bridging of a biodegradable biological conduit. The results showed that the biological conduit had good histocompatibility. Tissue and cell apoptosis in the conduit apparently lessened, and regenerating nerve fibers were common. The degeneration regeneration law of Schwann cells and axons in the conduit was quite different from that in traditional epineurium suture. During the prime period for nerve fiber regeneration(2–8 weeks), the number of Schwann cells and nerve fibers was higher in both proximal and distal ends, and the effects of the small gap sleeve bridging method were better than those of the traditional epineurium suture. The above results provide an objective and reliable theoretical basis for the clinical application of the biological conduit small gap sleeve bridging method to repair peripheral nerve injury.  相似文献   

16.
T‐H. Chu, L. Wang, A. Guo, V. W‐K. Chan, C. W‐M. Wong and W. Wu (2012) Neuropathology and Applied Neurobiology 38, 681–695 GDNF‐treated acellular nerve graft promotes motoneuron axon regeneration after implantation into cervical root avulsed spinal cord It is well known that glial cell line‐derived neurotrophic factor (GDNF) is a potent neurotrophic factor for motoneurons. We have previously shown that it greatly enhanced motoneuron survival and axon regeneration after implantation of peripheral nerve graft following spinal root avulsion. Aims: In the current study, we explore whether injection of GDNF promotes axon regeneration in decellularized nerve induced by repeated freeze‐thaw cycles. Methods: We injected saline or GDNF into the decellularized nerve after root avulsion in adult Sprague–Dawley rats and assessed motoneuron axon regeneration and Schwann cell migration by retrograde labelling and immunohistochemistry. Results: We found that no axons were present in saline‐treated acellular nerve whereas Schwann cells migrated into GDNF‐treated acellular nerve grafts. We also found that Schwann cells migrated into the nerve grafts as early as 4 days after implantation, coinciding with the first appearance of regenerating axons in the grafts. Application of GDNF outside the graft did not induce Schwann cell infiltration nor axon regeneration into the graft. Application of pleiotrophin, a trophic factor which promotes axon regeneration but not Schwann cell migration, did not promote axon infiltration into acellular nerve graft. Conclusions: We conclude that GDNF induced Schwann cell migration and axon regeneration into the acellular nerve graft. Our findings can be of potential clinical value to develop acellular nerve grafting for use in spinal root avulsion injuries.  相似文献   

17.
L1 is an adhesion molecule favorably influencing the functional and anatomical recoveries after central nervous system (CNS) injuries. Its roles in peripheral nervous system (PNS) regeneration are less well understood. Studies using knockout mice have surprisingly revealed that L1 has a negative impact on functional nerve regeneration by inhibiting Schwann cell proliferation. To further elucidate the roles of L1 in PNS regeneration, here we used a novel transgenic mouse overexpressing L1 in neurons, but not in PNS or CNS glial cells, under the control of a neuron-specific Thy-1 promoter. Without nerve injury, the transgene expression, as compared to wild-type mice, had no effect on femoral nerve function, numbers of quadriceps motoneurons and myelinated axons in the femoral nerve but resulted in slightly reduced myelination in the sensory saphenous nerve and increased neurofilament density in myelinated axons of the quadriceps motor nerve branch. After femoral nerve injury, L1 overexpression had no impact on the time course and degree of functional recovery. Unaffected were also numbers of regenerated quadriceps motoneurons, precision of muscle reinnervation, axon numbers and internodal lengths in the regenerated nerves. Despite the lack of functional effects, myelination in the motor and sensory femoral nerve branches was significantly improved and loss of perisomatic inhibitory terminals on motoneurons was attenuated in the transgenic mice. Our results indicate that L1 is a regulator of myelination in the injured PNS and warrant studies aiming to improve function in demyelinating PNS and CNS disorders using exogenous L1.  相似文献   

18.
Are Schwann cells essential for axonal regeneration into muscle autografts?   总被引:1,自引:0,他引:1  
When axons regenerate through frozen–thawed (FT) muscle grafts, they are accompanied by co–migrating Schwann cells derived from the nerve stumps. Although acellular, FT muscle grafts contain an internal scaffold of basal laminae rich in components capable of supporting neurite outgrowth in vitro such as laminin and fibronectin: it is not known whether Schwann cells are essential for axonal regrowth within these grafts. In this paper we test the hypothesis that sarcolemmal basal laminae will support axonal regeneration in the absence of Schwann cells. Two groups of 12 adult Wistar rats were used. All rats received a 0.5 cm FT muscle graft, and 12 rats also received a subperineurial injection of the anti–mi to tic agent mitomycin C (400 μg/ml in physiological saline) prior to grafting. Previous studies have shown that this dose effectively depresses cell proliferation within the endoneurium for 3–4 weeks [17, 18, 28]. Rats were killed ( n = 3) 1, 2, 3 or 4 weeks later. The spatio–temporal sequence of axonal regeneration into the grafts was assessed histologically, by immunofluorescence using antibodies against GAP–43; S–100; RT97; laminin and macrophages (EDI), and by transmission electron microscopy. Outgrowth of almost all axons from the mitomycin C–treated proximal stumps was delayed for up to 3 weeks, after which time vigorous regeneration occurred into the persisting tubes of sarcolemmal basal lamina. All axons regenerating within the grafts (irrespective of mitomycin C–treatment) were accompanied by co–migrating Schwann cells. The results suggest that Schwann cells play an important role in axonal regeneration across FT muscle autografts and that sarcolemmal basal laminae alone are insufficient to support axonal regeneration.  相似文献   

19.
At present, clinical strategies to repair injured peripheral nerve concentrate on efforts to attain primary suture of the cut nerve ends. If this is not possible, autografts are used to unite the separated nerve segments. Both strategies are based on the recognition that the Schwann cells resident in the peripheral nerve trunk play a crucial role in the regenerative process. Neither strategy may be feasible, however, in extensive or multiple injuries because the amount of autograft material is limited, and allografts are subject to immune rejection. Artificially produced nerve bridges constructed of autologous Schwann cells seeded in guidance channels could be used to overcome these limitations. In the present experiments, the potential of Schwann cells derived from adult nerves and seeded in permselective guidance channels to promote neurite regeneration across an 8 mm nerve gap was evaluated in transected rat sciatic nerves. Immunological sequalae were evaluated by comparing Schwann cells from syngeneic and heterologous rat strains. Schwann cells from either adult outbred (Sprague-Dawley, CD) rats or inbred (Fisher, F) rats were suspended in a Matrigel solution at a density of 80 x 10(6) cells/ml (CD) or 40, 80, or 120 x 10(6) cells/ml (F-40, F-80, and F-120 channels, respectively). Channels containing Schwann cells were compared to sciatic nerve autografts, empty channels, or channels filled with Matrigel alone. One day after seeding permselective synthetic guidance channels with a Schwann cell suspension, a central cable of Schwann cells oriented along the axis of the tube was formed due to syneresis of the hydrogel. By 3 weeks postimplantation, regenerating axons had grown into all channels and autografts. Sciatic nerve autografts supported extensive regeneration, containing 4-5 x 10(4) myelinated axons at the graft midpoint. The ability of channels containing syngeneic Schwann cells to foster regeneration was dependent on the Schwann cell seeding density. At the channel's midpoint, the myelinated axon population in F-120 tubes was intermediate between that in sciatic nerve autografts and F-80 channels, and was significantly higher than in F-40 or control channels. The nerve cable in Schwann cell-containing tubes consisted of larger, more organotypic fascicles than acellular control channels. In contrast, heterologous (CD) Schwann cells elicited a strong immune reaction that impeded nerve regeneration. The present study shows that cultured adult syngeneic Schwann cells seeded in permselective synthetic guidance channels support extensive peripheral nerve regeneration.(ABSTRACT TRUNCATED AT 400 WORDS)  相似文献   

20.
PURPOSE OF REVIEW: This article reviews recent experimental advances in the development of biosynthetic implants for repair of spinal cord injury. RECENT FINDINGS: Various important advances in the development of biosynthetic conduits for spinal cord repair have recently been reported. It was found that implantation of freeze dried alginate sponge into completely transected spinal cord supports axonal regeneration across the lesion site. A poly(lactic-co-glycolic acid) scaffold seeded with neural stem cells has been developed that promotes axonal regeneration across the gap. It was found that polyethylene glycol can reseal damaged spinal cord axons and restore impulse conduction. Findings have been reported that poly-beta-hydroxybutyrate conduits in combination with alginate and fibronectin provide neuroprotection for axotomized descending neurones. It has been reported that conduits made of fibronectin mats or fibrin in combination with neurotrophic growth factors promote axonal growth into the grafts. Finally, magnetic resonance imaging after experimental spinal cord injury has been used to monitor regeneration in biosynthetic conduits in vivo over time. SUMMARY: Biosynthetic conduits carrying extracellular matrix molecules and different cell lines, and supplemented with neurotrophic growth factors have yielded encouraging results in the treatment of experimental spinal cord injury. These findings provide a basis for further development of techniques aimed at spinal cord repair in humans.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号