首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Purpose

We evaluated with magnetic resonance imaging (MRI) the degradation and osteointegration features of a new type of bioabsorbable interference (BioRCI) screw composed of poly-L-lactic acid and hydroxyapatite (PLLA-HA) used for tibial graft fixation in anterior cruciate ligament (ACL) reconstruction.

Materials and methods

Thirty-one patients underwent arthroscopic surgery for ACL reconstruction using doubled gracilis and semitendinosus tendons fixed to the tibial tunnel with PLLA-HA (BioRCI-HA) screws. Two groups of patients were evaluated, one group 10–13 months after surgery and the other after 30–40 months. The standard knee ligament evaluation form of the International Knee Documentation Committee (IKDC) was used for clinical assessment and MRI for the radiological assessment.

Results

MRI after 10–13 months revealed findings referable to healing and integration of the bone-graft-screw system, findings that disappeared at later follow-up examinations. The BioRCI-HA screw remained constantly visible in all patients, although with changes in signal intensity over time.

Conclusions

BioRCI-HA screws allow adequate primary stability and superior osteoconduction and biocompatibility in comparison with plain PLLA screws. The absence of ferromagnetic artefacts allows accurate MRI follow-up and adequate evaluation of ligament synovialisation, screw degradation and graft osteointegration.  相似文献   

2.
Bioabsorbable interference screws are commonly used to secure the graft during anterior cruciate ligament (ACL) reconstruction, in part because they result in less image degradation on subsequent magnetic resonance imaging (MRI). However, some bioabsorbable screws are associated with abnormalities on MRI examination not reported with metallic interference screws. We describe a finding on knee MRI examination after ACL reconstruction using a polylactide carbonate (PLC) bioabsorbable screw that we believe to be previously unreported with any other bioabsorbable screws. The finding raised suspicion of hemorrhage or infection, neither of which were present clinically. Analysis of tissue from the tibial tunnel suggested an explanation for the MRI finding: calcite crystals. An additional five patients with knee MRI examinations after ACL reconstruction using a PLC screw were reviewed and correlated with clinical findings with four having similar imaging abnormalities present. The PLC (Calaxo screw, Smith and Nephew, Andover, MA) screw used in these patients has been recalled in the United States and Europe by the manufacturer after a greater than expected incidence of adverse reactions, and legal action may be pending.  相似文献   

3.
We retrospectively compared the clinical outcome and the radiographic incorporation of the bone blocks between two groups of patients undergoing anterior cruciate ligament reconstruction using either metallic or bioabsorbable interference screws for fixation of the bone-patellar tendon-bone autograft. Sixty-nine patients (44 male and 25 female) were available for follow-up. There were 31 patients with a mean age of 33 years (range 16–59 years) in group I (bioabsorbable interference screw fixation) and 38 patients with a mean age of 32 years (range 18–58) in group II (metallic screw fixation). The mean follow-up was 9.6 months after surgery in group I (range 6–17 months) and 20.5 months in group II (range 6–32 months). At follow-up, the IKDC scores were comparable between the two groups, and there was no statistically significant difference for the Lysholm (P = 0.925) and Tegner (P = 0.197) scores. The KT-2000 tests showed a statistically insignificant mean side-to-side difference of 2.0 mm (+2.2 mm SD) in group I and 2.2 mm (+2.4 mm SD) in group II (P = 0.741). At follow-up, all patients showed osseous incorporation of the bone block autografts within the femoral and tibial bone tunnels with no osteolytic changes.  相似文献   

4.
The aim of this study was to look at the clinical outcome of polylactide carbonate (PLC) interference screws in knee ligament reconstruction surgery. We prospectively followed up 59 patients who underwent primary hamstring anterior cruciate ligament (ACL) reconstructions using PLC (Calaxo screw; Smith and Nephew, Andover, MA) screws to secure the graft in the tibial tunnel. The average age was 34 years (range 17–55 years, SD 8.93). Twenty-three (39%) patients presented with complications [synovitis in 15% (nine) patients, prominent tibial swelling in 34% (20) patients and both in seven patients]. In comparison, similar complications were not seen in two groups of 59 age and sex matched patients in whom PLLA (Bio RCI; Smith and Nephew, Andover, MA) screws or Titanium (RCI; Smith and Nephew, Andover, MA) screws were used by the same surgeon. The problems encountered in the PLC screw group did not adversely affect knee stability. Six patients underwent exploration of the tibial tunnel site. A sterile white cheesy substance was removed, leaving an empty tibial tunnel. The ACL graft was found to be well attached to tibial tunnel in all cases. The PLC screw diameter, surface area or tibial tunnel diameter did not have any correlation to the occurrence of complications. Two patients required multiple washouts, one of whom developed a deep infection. The degradation of PLC screws does not follow the gradual and controlled pattern demonstrated in the ovine model. The unpredictable screw degradation, and the reaction to it can lead to serious clinical consequences.  相似文献   

5.
BACKGROUND: During the past decade, bioabsorbable interference screws have become increasingly popular in endoscopic reconstructions of the anterior cruciate ligament. With these screws, there is no need for a second operation for removal and no complicating factor if later revision surgery is necessary. Several pullout studies have found similar results between metal and bioabsorbable interference screws; however, few studies have investigated the clinical outcome. HYPOTHESIS: There is no difference in the clinical outcome of bioabsorbable interference screws compared with metal screws. STUDY DESIGN: Randomized controlled clinical trial; Level of evidence, 1. METHODS: Forty-one patients were randomized for the use of either metal interference screws (20 patients) or bioabsorbable poly-l-lactic acid screws (21 patients). The patients were followed with clinical examinations at 6, 12, and 24 weeks and at 1 and 2 years postoperatively. RESULTS: Subjective knee function was better in the patients in the metal screw group; they had less pain at rest, a higher Tegner score, a higher Lysholm score, and better subjective knee function at 2 years compared to the bioabsorbable screw group. However, there was no difference in stability between the groups.Conclusion and CLINICAL RELEVANCE: Because of the inferior results in the bioabsorbable screw group in our study, and until larger studies show otherwise, we do not find the advantages of using bioabsorbable screws sufficient to warrant the routine use of poly-L-lactic acid screws in anterior cruciate ligament reconstructions.  相似文献   

6.
BACKGROUND: Fixation strength of metal and bioabsorbable interference screws has not been evaluated while varying the anterior cruciate ligament graft tension angle. HYPOTHESIS: There is no difference in fixation strength between 2 types of interference screws for anterior cruciate ligament graft fixation while the graft tension angle is varied relative to the femoral tunnel. STUDY DESIGN: Controlled laboratory study. METHODS: Forty-eight anterior cruciate ligament reconstructions were performed using immature porcine femurs stripped of soft tissue and doubled-over porcine flexor digitorum profundus tendon grafts. Specimens were randomized to bioabsorbable or titanium interference screw fixation. Specimens were randomized to one of three pull angles (0 degrees , 30 degrees , 60 degrees ) representing loading at different knee flexion angles (n = 8/group). Reconstructed ligaments were tensioned to 10 N followed by 200 loading cycles between 10 and 150 N and a final failure test. Construct elongation (mm) at 100 and 200 cycles and failure load (N) were analyzed using a 2-way analysis of variance (P < .05). RESULTS: Screw material interacted significantly with graft tension angle, as the bioabsorbable screw specimens demonstrated significantly greater fixation strength when tensioned at greater angles. Specimens fixed with bioabsorbable screws showed significantly less elongation at both 100 and 200 cycles and significantly greater failure load compared with titanium screws. CONCLUSION: Bioabsorbable interference screws acutely have increased fixation strength compared with titanium interference screws for anterior cruciate ligament grafts loaded at greater tension angles. CLINICAL RELEVANCE: The strength of anterior cruciate ligament reconstruction fixation increases with increasing divergence between the tension angle and femoral tunnel, a condition seen when the knee approaches full extension.  相似文献   

7.
We evaluated the initial bone-patellar tendon-bone graft fixation strength of bioabsorbable as compared with titanium interference screws in anterior cruciate ligament reconstruction using matched pairs of porcine knees. Ten pairs underwent single-cycle failure loading at a rate of 50 mm/min, and 10 pairs underwent cyclic loading at half-hertz frequency. The cyclic loading started with 100 load cycles between 50 and 150 N. We then progressively increased loads in 50-N increments after each set of 100 cycles. After 100 cycles at 850 N, the specimens were loaded to failure at a rate of 50 mm/min. In the single-cycle failure loading test, the mean ultimate failure loads (+/-SD) for the bioabsorbable (837 +/- 260 N) and titanium interference screws (863 +/- 192 N) were not significantly different, nor were the mean yield loads or the stiffness of the fixation. In the cyclic loading test, the yield loads were 605 +/- 142 N and 585 +/- 103 N for the bioabsorbable and titanium interference screws, respectively (no significant difference). Although there was no significant difference in the ultimate failure load, more bone block fractures were found in the grafts fixed with a titanium interference screw. Bioabsorbable interference screw fixation thus seems to provide a reasonable alternative to titanium screws.  相似文献   

8.
There has never been an MRI study of tunnel widening comparing bioabsorbable to metal screw fixation in autologous hamstring anterior cruciate ligament (ACL) reconstruction. We randomized 62 patients to hamstring ACL reconstruction with either a bioabsorbable (n = 31) or metal screw (n = 31) fixation. The evaluation methods were clinical examination, KT-1000 arthrometric measurement, the International Knee Documentation Committee and Lysholm scores, and MRI. There were no differences between the groups preoperatively. Fifty-five patients (89%) were available at a minimum of 2-year follow-up (range 24–36 months). There was tunnel widening in both groups, but the increase was significantly greater in the AP dimension of the femoral tunnel in the bioabsorbable screw group compared to metal group (P = 0.01). The tibial tunnels showed no intergroup difference. Ninety-four percent of the knees were normal or nearly normal according to the IKDC scores and the average Lysholm score was 91 with no intergroup difference. The follow-up AP tibial tunnel diameter was smaller with normal knee laxity compared to abnormal knee laxity. The graft failure rate in the bioabsorbable screw group was 23% (7/31 patients) and 6% (2/31 patients) in the metal screw group. The use of bioabsorbable screws resulted in more femoral tunnel widening, and more graft failures compared to metal screws. The tunnel widening in the tibia was associated with the knee laxity (P = 0.02).  相似文献   

9.
Magnetic resonance (MR) imaging is contraindicated for patients with certain ferromagnetic implants, primarily because of potential risks related to movement or dislodgment of the devices. An additional problem with metallic implants is the potential image distortion that may affect the interpretation of the MR study. Since MR imaging is frequently useful for the evaluation of postoperative anterior cruciate ligament (ACL) reconstruction, the ferromagnetic qualities and artifacts associated with MR imaging were determined for five metallic orthopedic implants commonly used for this surgery. Only the Perfix interference screw displayed a substantial deflection force and caused extensive signal loss. Images of the knee of one patient with two Perfix screws in place were not interpretable because of the image distortion caused by these implants. Therefore, alternative nonferromagnetic implants should be considered for reconstruction of the ACL.  相似文献   

10.
Poly-l-lactic acid biodegradable screws have been used effectively for graft fixation in anterior cruciate ligament (ACL) reconstruction. The overall complication rate associated with the use of this implant is low, although some authors reported complications, such as osteolysis and aseptic effusion of the knee joint. We report a case of a 29-year-old female patient with a failure of a biodegradable interference screw at 22 months after ACL reconstruction using bone–patellar tendon–bone graft. In this illustrated case, the screw broke and migrated into the knee joint. In addition, we performed a detailed review of the medical literature from 1990–2005 to identify possible causes of biodegradable screw failures. We identified six published cases of bioabsorbable interference screw failure with migration into the knee joint. Several authors have reported small diameter of the screw, poor bone quality, bone resorption, and screw divergence as potential causes for intraarticular migration of metallic interference screws. With regard to bioscrews, no specific risk factors for screw breakage and intraarticular migration have been reported. ACL reconstruction with the use of bioabsorbable interference screws for fixation is considered to be reliable. However, we need to be aware of potential problems associated with the use of this implant. Early recognition of bioscrew failure may prevent associated morbidities, such as subsequent cartilage damage.  相似文献   

11.
BACKGROUND: To date, there has been no publication of clinical follow-up data on patients who have undergone quadrupled hamstring tendon autograft anterior cruciate ligament reconstruction with bioabsorbable screw fixation. PURPOSE: To report the results of quadrupled hamstring tendon autograft anterior cruciate ligament reconstruction with bioabsorbable interference screw fixation. STUDY DESIGN: Retrospective review. METHODS: Sixty-five patients (66 knees) were retrospectively identified by chart review as having undergone quadrupled hamstring tendon autograft anterior cruciate ligament reconstruction with bioabsorbable interference screw fixation with a minimum 2-year follow-up. RESULTS: Data were collected on 48 knees in 47 patients (73%) at an average 30.2 months (range, 24 to 43) after surgery. Thirty-six patients (37 knees) returned for clinical evaluation (56% return) and subjective follow-up only was obtained in 11 patients (17%). The mean Lysolm knee score was 91 (range, 45 to 98), with a mean of 97 for the uninvolved knee. The mean Tegner activity score was 5.7 (range, 3 to 7). The KT-1000 arthrometer mean side-to-side difference for manual maximum displacement was 2.03 mm (range, -1 to 8). The mean International Knee Documentation Committee knee score was 83 (range, 47 to 100). Patients who underwent associated partial meniscectomy or meniscal repair had significantly lower International Knee Documentation Committee scores than patients without associated procedures (P < 0.01). CONCLUSIONS: Quadrupled hamstring tendon autograft anterior cruciate ligament reconstruction with bioabsorbable interference screw fixation is comparable with other methods of anterior cruciate ligament reconstruction in terms of patient satisfaction, knee stability, and function.  相似文献   

12.
BACKGROUND: Metal interference screws can cause problems if revision is needed and can interfere with magnetic resonance imaging. Bioabsorbable screws have been developed to prevent these problems, but the rate of resorption and integration is not well understood. HYPOTHESIS: Poly-L-lactic acid interference screws will be resorbed 2 years after anterior cruciate ligament reconstruction. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: The study group consisted of 19 patients with isolated anterior cruciate ligament ruptures reconstructed with bone-patellar tendon-bone autografts fixed with poly-L-lactic acid interference screws using an endoscopic technique. Magnetic resonance imaging was used to evaluate resorption of the screws, bony integration of the screws, and integration of the bone blocks after 2 years. RESULTS: At 2 years, the mean reduction in the volume of the femoral screws was 64% and of the tibial screw was 63%. Bony integration of the femoral bone block was considered good in 17 patients and fair in 2 patients. Integration of the tibial bone block was considered good in 16 patients and fair in 1 patient who demonstrated widening of the tibial tunnel. Osteolysis around the screws was seen in 3 patients in the femur and none in the tibia. CONCLUSION: The mean reduction in volume of the poly-L-lactic acid screws as measured by magnetic resonance imaging after 2 years was approximately two thirds. The integration of the bone blocks was considered good in 90% of the patients. Osteolysis around the screws was visible in 16% of the patients. CLINICAL RELEVANCE: Two years after ACL reconstruction using poly-L-lactic acid interference screws, the surgeon can expect to find approximately one third of the volume of the screw remaining in the bone tunnels.  相似文献   

13.
PURPOSE: To examine at magnetic resonance (MR) imaging the degradation of an interference screw made of polyglycolic acid (67.5%) and trimethylene carbonate (32.5%) and compare the MR findings with the clinical evaluation results. MATERIALS AND METHODS: Clinical and MR imaging studies were performed concomitantly 6 months (in 20 patients), 1 year (in 10 patients), and 2 years (in eight patients) after surgery. Screw resorption rate, tibial tunnel appearance and contents, epiphyseal reaction, reconstructed ligament appearance, bone plug healing, joint effusion, and synovitis were evaluated. RESULTS: The screw was observed to be partially resorbed (by approximately one-third) at 6 months and totally resorbed at 1 year. Enhancement of the tunnel content, which can be linked to bone healing and screw replacement, was seen without a surrounding inflammatory reaction. Bone tunnel enlargement was observed and remained stable over time; this phenomenon has often been reported with metallic or polylactic acid interference screws and could be due to the position of the screw within the tunnel. The tissue that was seen at MR imaging to be replacing the screw was either fibrous or fatty and fibrous but never bone. CONCLUSION: Resorption of the screw does not appear to be related to clinical results.  相似文献   

14.
The goals of this study were to evaluate torsional strength and modes of failure in commercially available bioabsorbable interference screws and to test the effect of screw diameter on torsional strength when screws become jammed during insertion. We tested the Arthrex, BioScrew, Endo-Fix, Phantom, and Sysorb screws, all 20 mm in length. Four major modes of failure were encountered. Analysis of variance revealed that both screw type and diameter had a significant effect on failure torque. The Endo-Fix 7-mm screw had the lowest failure torque (1.07 +/- 0.18 N x m) and the Sysorb 8-mm screw had the highest (5.23 +/- 0.24 N x m). The Sysorb was significantly stronger than all the other screws. The failure torques were within the range that has been reported for manual screw insertion. We concluded that technical factors, which can affect insertion torque, assume particular importance with the use of bioabsorbable interference screws.  相似文献   

15.
The aim of the study was to assess the hard tissue response of a composite hydroxyapatite/poly L-lactic acid (HA/PLLA) interference screw for anterior cruciate ligament (ACL) reconstruction compared to a standard PLLA screw. Twelve skeletally mature rams underwent unilateral ACL reconstruction using an autologous bone-patellar tendon graft. Each animal received either two test HA/PLLA interference screws or two control PLLA interference screws. Animals were sacrificed at 6 and 12 months post-implantation and the operated knees excised. Undecalcified sections of the screw and surrounding tissues were cut from resin embedded samples and stained; sections were approximately parallel to the longitudinal axis of the screws. A quantitative assessment of bone formation between each screw type (PLLA vs. HA/PLLA) and adjacent tissue in both the tibia and femur was undertaken using automated image analysis (KS400, Zeiss, UK). The inflammatory response of each screw type was assessed by histological evaluation. New bone formation along the perimeter of the screw threads was statistically significantly higher with the HA/PLLA than the PLLA alone. The inflammatory response as assessed semi-quantitatively by histologically determining the number of inflammatory cells present in the tissue adjacent to the implant, was higher for PLLA than HA/PLLA. Significantly increased new bone formation and decreased inflammatory cells were observed in vivo with the composite screw in comparison with the standard polymer. A novel HA/PLLA composite biomaterial in the form of an interference screw demonstrated an improved hard-tissue response compared to PLLA in a large animal ACL reconstruction. This study determined the differences in the tissue response between PLLA and a composite material of HA/PLLA. The improved tissue related outcomes observed in vivo, may be of benefit clinically in ACL reconstruction.  相似文献   

16.
Developing bio-absorbable interference screws for anterior cruciate ligament (ACL) reconstruction has proven to be a challenging task. The aim of this study was to investigate the osteogenetic response of poly-lactide carbonate (PLC) interference screws in ACL reconstruction in humans. Ten patients (median age, 28 years) underwent arthroscopic ACL reconstruction with semitendinosus/gracilis tendon graft and a PLC interference screw. The patients were scanned with a multi-slice CT scanner 2 weeks and 1 year postoperatively. Fourteen days postoperatively a mean tunnel widening of 78% [52%; 110%] was observed. At 1-year follow-up, the mean tunnel widening was 128% [84%; 180%]. No sign of bone replacement or bone ingrowth was observed. Factors such as accelerated rehabilitation, micro-motions, and early screw degradation might be responsible for this large tunnel widening. Our results demonstrate the difficulty in translation of preclinical data. This study illustrates the need for extensive preclinical investigation of new materials for clinical purposes.  相似文献   

17.
目的 通过前瞻性随机对照研究评估金属(钛合金)和生物可吸收(多聚左旋乳酸)螺钉固定下胫腓联合的疗效,并分析潜在的并发症风险.方法 2007年1月- 2008年5月共48例踝关节骨折伴下胫腓联合损伤患者入组.通过随机数字表法实现完全随机分组,其中金属螺钉固定组20例,可吸收螺钉固定组28例.47例患者接受至少2年的随访,进行影像学和临床评估.结果 总随访率达98%.两组患者人口学信息差异无统计学意义(P>0.05).随访满1年及2年时,两组间Baird评分各指标、总分及Baird评级差异均无统计学意义(P>0.05).至随访末,两组患、健侧踝关节之间活动度差异有统计学意义(P<0.05).可吸收螺钉组主要出现2例中度排异反应及2例下胫腓异位骨化并发症.结论 可吸收螺钉是下胫腓联合损伤固定的有效内置物,与金属材料螺钉相比,可避免二次手术取出,同时可以达到与前者相同的固定效果.但其也存在多种并发症的可能,如排异反应及异位骨化等不容忽视.  相似文献   

18.
关节镜下自体四股腘绳肌腱重建膝前交叉韧带   总被引:9,自引:0,他引:9  
目的评估关节镜下自体四股腘绳肌腱重建膝前交叉韧带(ACL)的技术和效果方法1999年10月-2003年12月共56例患者经关节镜检查证实为ACL断裂,26例伴半月板破裂,7例伴内侧副韧带损伤,12例伴后交叉韧带断裂。均于关节镜下行自体四股腘绳肌腱ACL重建术,采用Bionx生物可吸收挤压螺钉或钛挤压螺钉解剖位固定重建韧带。结果本组术后早期均未发生严重并发症。术后随访6-48个月,平均20个月,Lysholm膝关节功能评分由术前45-80分(平均58.36分),提高至随访时70-100分(平均92.77分)(P<0.01)。国际膝关节文件编制委员会(IKDC)综合评定由术前异常(C级)14例、显著异常(D级)42例,改进为随访时正常(A级)23例、接近正常(B级)29例、异常(C级)4例(P<0.01)。56例患者中,52例恢复伤前运动水平,4例运动水平较伤前降低。结论关节镜下自体四股腘绳肌腱重建膝ACL具有手术损伤较小、术后膝关节功能恢复良好的优点,值得采用。  相似文献   

19.
PURPOSE: Anterior cruciate ligament reconstructions are becoming increasingly frequent, and MRI has been shown to be the best imaging modality for the non-invasive assessment of surgical outcome. Use of the quadriceps tendon as a biological replacement for injured cruciate ligament is a recent innovation. This study evaluated by MRI the results of anterior cruciate reconstruction in 27 consecutive patients who underwent arthroscopic reconstruction with homologous quadriceps tendon. MATERIAL AND METHODS: MRI was carried out on 27 patients who had undergone anterior cruciate ligament reconstruction with the middle third of the homolateral quadriceps tendon. The examinations were performed on two MRI units: a permanent 0.2-Tesla dedicated magnet (Artoscan, Esaote Italy) and whole-body 1.5-Tesla superconducting magnet (Signa, GE Medical Systems Milwaukee, Winsconsin USA). Axial, sagittal and coronal images were acquired with SE, GE and STIR fat suppression sequences. The examinations were performed 1, 3, and 6 months post-operatively in 16 patients, and 1 and 3 post-operatively in 11 patients. The same arthroscopic surgical technique was employed in all patients, with 20 cases of tibial mono-tunnel femoral semi-tunnel, and 7 cases with tibial bi-tunnel technique. All patients were assessed by arthrometric and clinical tests after surgery. Bioabsorbable interference screws were used for tibial fixation in all patients and metallic interference screws were used for femoral graft fixation in 8 patients. RESULTS: In all cases MRI correctly visualised the tunnel positions, the articular portion and the bone-portion of the graft inside the tibial and femoral tunnels. The absence of paramagnetic artefacts in the tibia allowed complete visualisation on the axial, sagittal and coronal MRI images with optimal spatial and contrast resolutions. In 6 cases, the presence of metal residues from the surgical cutter prevented correct evaluation of femoral tunnel content. No new graft or articular lesions were found. In 18/27 cases peri-focal marrow edema around the tibial tunnel had disappeared 3 months after surgery. The process of synovial incorporation was judged to be correct in all cases. DISCUSSION: The use of anterior cruciate ligament reconstruction with the quadriceps tendon is a important innovation given the size of the harvested material and the possibility of completely filling the osseous tunnels, without interposition of synovial proliferation or fluid collection between tendon and bone, as confirmed by MRI. Furthermore, the use of non-metallic screws allows MRI evaluation of tunnel content and oedema in the spongy bone around the tunnel. The study of the double tibial tunnel requires specific obliqueness in the coronal plane scans. CONCLUSIONS: This arthroscopic technique for anterior cruciate ligament reconstruction allows thorough MRI evaluation of all portions of the transplant, and in particular those coursing within the tibia and femur. The absence of bone oedema around the tunnels and synovial proliferation within the tunnels may be predictive of faster healing and complete bone incorporation of the grafts.  相似文献   

20.
Two cases are reported in which, after ACL reconstruction with autologous hamstring grafts, tibial polylactide interference screws migrated into the knee joint. Clinically, both patients presented with recurrent locking of the joint. In one case, a broken 15 mm-long tip of the screw was found intra-articularly. In the other case, the whole screw had migrated into the joint cavity. The degradation process of polylactic acid, operative technique and bone quality are discussed as possible reasons for these complications.  相似文献   