首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Nasal polyps are characterized by eosinophilic infiltration, and frequently coexist with asthma, aspirin intolerance and allergy. Eosinophilic cationic protein (ECP) is a specific eosinophil granule protein released upon activation of eosinophils. We investigated the ECP levels in nasal secretions of patients with nasal polyposis (NP) in order to correlate them with disease severity and associated diseases and to compare ECP levels between patients with and without recurrence of NP after surgical treatment. A total of 78 patients who had surgery for NP were followed up for a minimum of 18 months. The presence of asthma, allergies or aspirin intolerance was noted. Nasal secretions were obtained 1 day before the surgery and during the follow-up period after surgery. Immunoassays were used to quantify ECP in nasal secretions and serum and interleukin (IL)-5 in nasal secretions. ECP levels in nasal secretions were higher in patients with asthma or aspirin intolerance than in patients without asthma or aspirin intolerance, while no significant differences were found between allergic and non-allergic patients. ECP levels in nasal secretions correlated significantly with IL-5 levels in nasal secretions, the degree of tissue eosinophilia and computed tomographic (CT) scores. In total, 30 patients (38%) developed recurrent NP during the follow-up period. Preoperative ECP and IL-5 levels in nasal secretions were significantly higher in patients with recurrence compared to patients without recurrence. During the follow-up period, patients without recurrence demonstrated a significant reduction in the ECP levels in nasal secretions, whereas there was no significant reduction in the ECP levels of patients with recurrence. The results of this study provide evidence that ECP levels in nasal secretions of patients with NP correlate with the presence of asthma or aspirin intolerance and severity of NP determined by CT scores.  相似文献   

2.
In 25 patients with mite nasal allergy and 13 healthy control subjects, levels of eosinophil cationic protein (ECP) and histamine in nasal secretions were examined before and after challenge with mite extract. The ECP level was found to be significantly higher in the washings taken 30 minutes after challenge compared with the washings taken before challenge (P<.05). ECP levels measured both before and after mite extract challenge were found to be significantly higher in the patients than in the controls (P <.01). These facts suggest that the ECP affects the nasal mucosa by causing injury to ciliated cells and by acceleration of the processes of modification and inhibition of the allergic reaction.  相似文献   

3.
Allergic rhinitis (AR), nasal polyps (NP) as well as chronic rhinosinusitis (CRS) are all known to be associated with eosinophilic infiltration and elevated numbers of mast cells (MC) within the mucosa. Both cell types and their markers eosinophilic cationic protein (ECP) and tryptase are utilized in the diagnosis and management of chronic sino-nasal diseases. Mucosal cytology samples were gathered by cytobrush, histological samples were obtained from the inferior turbinate. In both sample sets, the number of eosinophils and MC was determined. Their corresponding markers ECP and tryptase were quantified from nasal discharge. Patients were grouped with reference to their main diagnosis: AR (n = 34), NP (n = 25), CRS (n = 27) and controls (n = 34). Eosinophil counts from cytobrush and ECP levels were significantly elevated in NP compared to all other groups—31- and 13-fold over control, respectively. However, histologic review did not reveal any difference in eosinophil count among groups. Tryptase was significantly elevated threefold in AR versus CRS and controls. No correlation to cytological and histological MC counts could be found. ECP levels in nasal discharge as well as eosinophil counts can provide useful information with regard to the diagnosis. Likewise, tryptase concentrations can do. The presented data show that the measurement of markers in nasal discharge is superior in differentiating among diagnosis groups. Given that the collection of nasal secretions is more comfortable for patients than the more invasive techniques, we recommend first line ECP and tryptase testing performed on nasal secretions.  相似文献   

4.
5.
The release of toxic granule proteins from the eosinophil granulocytes is generally believed to play a crucial part in the development of allergen-induced lesions of the barrier function leading to such clinical features of continuous allergic airway disease as oedema, hypersecretion, changes in responsiveness to specific and non-specific stimuli and, in the case of the lower airways, bronchoconstriction. In the upper airways, a nasal challenge/rechallenge model has proved useful in the study of the allergic inflammatory response in hay fever patients both in experimental settings and during natural pollen exposure. Repeated nasal lavage procedures and challenges with methacholine following an initial challenge with different doses of allergen or placebo were performed in 16 hay fever patients. Following an immediate allergic reaction, a statistically significant increase in the secretory response to methacholine was seen 30 min after challenge with the higher doses of allergen (p less than 0.01) but not after the lowest dose or placebo. An influx of eosinophil granulocytes was seen within 30-60 min of the allergen challenge regardless of the dose (p less than 0.01). The activation of these cells was measured by the increased levels of ECP (eosinophil cationic protein) in the nasal lavage fluid. No relationship was found between individual changes in eosinophils or levels of ECP and changes in the secretory response to methacholine or nasal symptoms. This lends further support to our previous observations that eosinophil granulocytes are not necessarily linked to allergen-induced changes in nasal secretory responsiveness.  相似文献   

6.
OBJECTIVES: Evaluation was made of eosinophilic cationic protein (ECP) in nasal secretion for measuring the degree of nasal inflammation and monitoring response to therapy in cystic fibrosis (CF) patients with chronic rhinosinusitis. Symptoms and findings in regard to ECP levels before and after treatment were described. STUDY DESIGN: Study was prospective, with 21 CF patients aged 4 to 19 years; 20 healthy volunteers served as controls. Collection of nasal secretion by a sponge was performed, and blood samples were obtained for serum. Cystic fibrosis (CF) patients were classified according to nasal symptoms and findings. METHODS: ECP was measured by fluoroimmunoassay. Age, sex, nasal symptoms, and endoscopic and histological findings were obtained, and examinations were conducted before and after treatment; recurrences were recorded. RESULTS: In CF patients with chronic nasal inflammation, increased nasal levels of ECP were detected when compared with asymptomatic CF patients or healthy nonatopic subjects. ECP concentrations were strongly related to the extent of nasal disease; patients with nasal polyps had higher levels than those without. Checked at 1 and 4 months after treatment, ECP levels declined with regression of symptoms, and in patients with exacerbation of nasal disease, ECP levels rose. CONCLUSIONS: According to our study, there is a relationship between levels of ECP in nasal secretions and the degrees of nasal inflammation. In addition, the measurement of ECP could be useful in monitoring nasal disease in CF patients.  相似文献   

7.
慢性鼻窦炎鼻息肉与变应性因素相关性的探讨   总被引:24,自引:0,他引:24  
目的 探讨变应性因素在慢性鼻窦炎鼻息肉发病中的作用。方法回顾性分析1882例慢性鼻窦炎鼻息肉患者术前鼻腔分泌物涂片嗜酸粒细胞及变应原皮肤试验检查结果,并将其变应性症状和体征出现的比例与临床分型分期加以比较。结果①1882例慢性鼻窦炎鼻息肉患者中60.4%(1137例)的患者伴有不同程度的变应性症状和体征,25.3%(477例)的患者合并变应性鼻炎,2.1%(39例)的患者合并支气管哮喘;②在Ⅰ型(708例)和Ⅱ型(823例)各分期的患者中,合并变应性鼻炎及支气管哮喘的发生率和嗜酸粒细胞、皮肤变应原试验阳性率以及变应性鼻炎临床症状出现的百分率分别由低到高出现,Ⅱ型3期各项比例最高;③42.2%(795例)的患者变应原皮肤试验阳性,其中94.3%对常年性变应原呈阳性反应;④26.3%(495例)的患者伴有变应性鼻炎的临床症状,其中99.8%(494/495例)为常年性发作;⑤有前期手术史的病例占38.9%(732例),其中合并变应性鼻炎者占有前期手术史例数的38.3%(280例),占合并变应性鼻炎患者的58.7%(477例)。结论变应性因素特别是常年性变应性鼻炎与慢性鼻窦炎鼻息肉的病变程度和病变范围有关。同时变应性鼻炎也促进了疾病的复发。  相似文献   

8.
By using a microsuction technique, a quantitative determination of chemical mediators in nasal secretions was performed in 18 hay-fever patients and in a control group of 10 healthy volunteers. The authors then compared these quantitative data for mediators with objective nasal findings counting the number of sneezes, passive anterior rhinomanometry (PAR) and nasal inspiratory peak flow. A sampling protocol was designed with a follow-up of 3 days after nasal allergen challenge (NAC) in order to investigate both early and late allergic reactions. Median baseline concentrations of five major mediators were obtained: histamine, 19 ng/g; leukotriene C4 (LTC4), 5.7 ng/g. tryptase, 0; prostaglandin D2 (PGD2), 477 pg/g; eosinophil cationic protein (ECP), 105 ng/g. Significant increases in histamine (214 ng/g) , LTC4 (20 ng/g) and tryptase (28 μU/g) were found, but a significant decrease occurred in ECP (47 ng/g) and PGD (226 pg/g) immediately after NAC in the patients studied. Most ECP concentrations (94%) increased slowly 1 h after NAC and reached a significantly higher level 24 h later. In evaluating nasal symptoms, sneezes were present in a high percentage of cases (76%) during the early phase but were uncommon during the late phase (29%). Total nasal obstruction occurred in 94% during the early phase. In contrast, unilateral nasal obstruction presented in 82% during the late phase, whereas total nasal obstruction was present only in 41%. The most common type of late phase nasal obstruction shown by PAR was alternating nasal obstruction.  相似文献   

9.
By using a microsuction technique, a quantitative determination of chemical mediators in nasal secretions was performed in 18 hay-fever patients and in a control group of 10 healthy volunteers. The authors then compared these quantitative data for mediators with objective nasal findings counting the number of sneezes, passive anterior rhinomanometry (PAR) and nasal inspiratory peak flow. A sampling protocol was designed with a follow-up of 3 days after nasal allergen challenge (NAC) in order to investigate both early and late allergic reactions. Median baseline concentrations of five major mediators were obtained: histamine, 19 ng/g; leukotriene C4 (LTC4), 5.7 ng/g. tryptase, 0; prostaglandin D2 (PGD2), 477 pg/g; eosinophil cationic protein (ECP), 105 ng/g. Significant increases in histamine (214 ng/g) , LTC4 (20 ng/g) and tryptase (28 μU/g) were found, but a significant decrease occurred in ECP (47 ng/g) and PGD (226 pg/g) immediately after NAC in the patients studied. Most ECP concentrations (94%) increased slowly 1 h after NAC and reached a significantly higher level 24 h later. In evaluating nasal symptoms, sneezes were present in a high percentage of cases (76%) during the early phase but were uncommon during the late phase (29%). Total nasal obstruction occurred in 94% during the early phase. In contrast, unilateral nasal obstruction presented in 82% during the late phase, whereas total nasal obstruction was present only in 41%. The most common type of late phase nasal obstruction shown by PAR was alternating nasal obstruction.  相似文献   

10.
为了观察变应性鼻炎(allesgicrhinitis,AR)患者鼻分泌物中的上皮细胞集落和嗜酸粒细胞,对20例AR患者(AR组)和15例鼻窦炎患者(感染组)鼻分泌物中细胞成分进行了电镜观察,发现AR组鼻分泌物中有大量上皮细胞集落,其特征是数个至数十个上皮细胞成片状脱落,上皮细胞集落的数量和嗜酸粒细胞的数量、嗜酸粒细胞阳离子蛋白(eosinophiliccationicprotein,ECP)的含量呈正相关。感染组中上皮细胞集落和嗜酸粒细胞极少,ECP含量甚微。结果提示嗜酸粒细胞的ECP可能导致AR患者的鼻粘膜上皮呈片状脱落,对上皮结构造成损害。  相似文献   

11.
BACKGROUND: Mucosa-immunologic aspects are gaining an increasing awareness in the pathophysiology of type I allergies. Humoral mucosal immune responses are dominated by secretory IgA, but there is evidence for a relevant role of IgG in nasal mucosa-associated lymphoid tissue. OBJECTIVE: was to measure allergen-specific immunoglobulins (IgA and IgG) in nasal secretions as an expression of a humoral mucosal immune response in allergic rhinitis. For tissue eosinophilia we studied nasal Eosinophilic Cationic Protein (ECP) and for mast cell activation nasal tryptase. METHODS: Nasal secretions of 40 patients suffering from allergic rhinitis were analyzed for allergen-specific IgA, IgG, and IgE, and for ECP and tryptase. Patients were highly sensitized against the major allergens of house dust mites, timothy, and birch pollen. 43 non-atopic individuals served as controls. In order to study possible effects of the actual pollen season on the studied parameter we secondly compared patients allergic to seasonal allergens co- (n = 28) and extra-seasonally (n = 41). In order to determine a possible influence of allergen-specific IgA in eosinophilic degranulation we additionally studied 5 patients after nasal allergen challenge. RESULTS: In allergic rhinitis we found significantly increased levels of allergen-specific immunoglobulins of all studied subclasses and allergens in nasal secretions. Comparison of nasal ECP and tryptase showed significantly increased concentrations in allergic individuals as well. Co-seasonally we found elevated allergen-specific IgE, ECP, and tryptase but lower concentrations of allergen-specific IgA and IgG. There was no association between late phase eosinophilia and IgA concentrations after local allergen challenge. CONCLUSIONS: The occurrence of allergen-specific immunoglobulins in nasal secretions is interpreted as a local humoral mucosal immune response. The physiologic role of local allergen-specific immunoglobulins is not clear to date. Involvement in degranulation of eosinophils or mast cells, like suggested before, seems unlikely.  相似文献   

12.
OBJECTIVE: To compare concentrations of interleukin-5 (IL-5), immunoglobulin E (IgE), eosinophilic cationic protein (ECP), and soluble intercellular adhesion molecule-1 (sICAM-1) in nasal secretion and serum of patients with chronic nonallergic sinusitis, allergic rhinitis, and nonallergic nasal polyposis to obtain information about the pathogenesis of these diseases. METHODS: Nasal secretion and serum were analyzed by routine enzyme-linked immunosorbent assay techniques. Nineteen patients with chronic nonallergic sinusitis, 24 patients with seasonal allergic rhinitis, and 18 patients with nonallergic nasal polyposis were included in the study. Eight healthy, nonallergic probands served as control subjects. RESULTS: Significantly elevated concentrations of IL-5 (5-fold, P < .05) and IgE (15-fold, P < .01) were detected in nasal secretion of patients with allergic rhinitis (IL-5, 51.8 +/- 13.2 pg/mL; IgE, 41.9 +/- 20.9 kU/L) or nonallergic nasal polyposis (IL-5, 57.9 +/- 36.9 pg(mL; IgE, 40.5 +/- 20.2 kU/L) compared with controls (IL-5, 10.6 +/- 7.8 pg/mL; IgE, 2.8 +/- 0.5 kU/L) or with patients with chronic nonallergic sinusitis (IL-5, 16.5 +/- 13.2 pg/mL; IgE, 5.4 +/- 3.1 kU/L). There were no significant differences between patients with allergic rhinitis and those with nonallergic nasal polyposis. Concentrations of ECP were significantly elevated (sixfold, P < .01) in patients with allergic rhinitis (297.8 ng/mL +/- 173.1) compared with controls (52.4 +/- 28.0 ng/mL) or patients with chronic nonallergic sinusitis (44.8 +/- 40.1 ng/mL), whereas twofold higher concentrations (not significant) of ECP were observed in patients with nonallergic nasal polyposis (107.1 +/- 26.6 ng/mL). Significantly elevated concentrations of sICAM-1 in nasal secretion (threefold, P < .05) were detected only in patients with chronic nonallergic sinusitis (79.4 +/- 45.6 ng/mL). The elevated sICAM-1 nasal secretion values in this group correlated significantly (P < .05) to the serum values. CONCLUSIONS: Equally elevated concentrations of IL-5 and IgE in patients with allergic rhinitis and nonallergic nasal polyposis implicated similar pathogenic processes in both diseases. Whereas the pathogenesis of allergic rhinitis is IgE-specific, the pathogenesis of nasal polyps is not as clear. IL-5 was suggested to play a pivotal role in tissue eosinophilia, which was confirmed by data in the present study. Elevated concentrations of ECP were suggested to result from tissue eosinophilia--a characteristic of both diseases. Elevated concentrations of sICAM-1 in patients with chronic nonallergic sinusitis pointed to its key role in the recruitment of neutrophils into the inflamed tissue, whereas an important role in eosinophil recruitment was ruled out.  相似文献   

13.
Acute and late phase (dual) symptomatic responses after allergen challenge commonly occur in allergic asthma. The aim of the present study was to explore the occurrence of allergen challenge-induced biphasic responses in patients with chronic perennial allergic rhinitis living in an area with high house dust mite (HDM) exposure. Fifteen patients with perennial rhinitis and evident allergy to HDM participated. Nasal challenges with HDM and sham were performed on separate days in a crossover design. Nasal symptoms, forced expiratory volume in 1 s (FEV1) and orally exhaled nitric oxide were recorded every hour for up to 8 h after each challenge. Alpha2-macroglobulin and eosinophil cationic protein (ECP) were analysed in hourly nasal lavages, and nasal histamine provocations were carried out after 8 h. HDM, but not sham, caused an immediate increase in nasal symptoms which gradually abated over the 8-h period. No reoccurrence of nasal late phase symptoms was seen. HDM, but not sham, induced an early increase in alpha2-macroglobulin and ECP levels: both indices remained elevated for up to 3 h after challenge. HDM challenge evoked hyper-responsiveness to histamine expressed as increased nasal symptoms (p < 0.05; HDM vs sham). No differences in exhaled nitric oxide or FEV1 were demonstrated at any one time point between the HDM- and sham-challenged days. It is concluded that nasal symptomatic and exudative late phase responses may not be a general feature, even in subjects with perennial rhinitis challenged with high, symptom-provoking, doses of HDM allergen.  相似文献   

14.
BACKGROUND: Although patients with nasal polyposis frequently exhibit concomitant allergy, there is limited information about the impact of allergy on the severity of nasal polyposis. The goal of this study was to evaluate the role of allergy in the severity of nasal polyposis. METHODS: Polyp sizes, computed tomography (CT) scores, skin-prick test results, blood total eosinophil count, serum levels of total immunoglobulin E, symptom scores, and recurrences were analyzed in 83 patients with nasal polyposis. The results were compared between allergic and nonallergic patients with nasal polyposis. RESULTS: No association was found between the presence of allergy per skin-prick testing and polyp size, CT opacification, symptom scores, or recurrences (p > 0.05). In allergic patients, only the serum total eosinophil count correlated strongly with the results of CT (p = 0.005) but not with other parameters (p > 0.05). CONCLUSIONS: The results of this study show that, although patients with nasal polyposis frequently have allergies, the presence of allergy does not correlate with polyp size, symptom scores or rate of recurrence.  相似文献   

15.
OBJECTIVE: To evaluate the role of eosinophil cationic protein (ECP) and serum soluble E-selectin (sE-selectin) in patients with allergic rhinitis. METHODS: The sE-selectin were detected from 30 allergic patients and 20 normal individuals by enzyme-linked immunosorbent assay (ELISA). The ECP in serum and nasal lavage fluid was assayed with pharmacia CAP system. RESULTS: The level of sE-selectin in patients with allergic rhinitis was(41.846 +/- 12.21) ng/ml, higher than that in control (10.678 +/- 2.458) ng/ml. The level of ECP in serum and nasal lavage fluid from patients with allergic rhinitis was significantly higher than that from normal controls. The level of ECP in nasal lavage fluid was much higher than that in serum. CONCLUSION: ECP and sE-selectin play a role in pathogenesis of allergic rhinitis.  相似文献   

16.
目的分析变应性鼻炎引起嗅觉障碍的发病机制。方法选取216例变应性鼻炎患者作为实验对象,同时选取99例健康志愿者作为对照组。采用嗅棒气味嗅觉测试方法测定两组患者的嗅觉功能;采用酶联免疫吸附法检测鼻腔分泌物中嗜酸性粒细胞阳离子蛋白(eosinophil ationicprotein,ECP)及类胰蛋白酶的含量;应用鼻压计测定鼻气道阻力。结果变应性鼻炎患者鼻气道阻力与对照组比较差异无统计学意义(P〉0.05);变应性鼻炎组患者嗅觉功能,鼻腔分泌物ECP和鼻腔分泌物类胰蛋白酶与对照组比较,差异具有统计学意义(P〈0.05)。结论嗜酸性粒细胞和肥大细胞的活性增加可能导致了变应性鼻炎患者的嗅觉障碍,而鼻腔阻塞可能不是引起变应性鼻炎患者嗅觉障碍的主要原因。  相似文献   

17.
Eosinophilia is associated with several diseases of the upper respiratory tract. The predominance of eosinophils in nasal tissue, secretions, and lavage fluid has been used as an aid in the diagnosis of allergic rhinitis. Charcot-Leyden crystals, considered to be a morphologic hallmark of eosinophil-related disease, are often also found in inflamed nasal tissue and paranasal sinus contents of patients with allergic rhinitis. These bipyramidal-shaped crystals are composed of the enzyme lysolecithin acylhydrolase, one of several eosinophilic proteins that damage respiratory epithelium and contribute to the pathology of allergy in the upper respiratory tract.  相似文献   

18.
Conclusions. Infiltration and activation of eosinophils is a characteristic of nasal polyposis. Allergic reaction is a risk factor for the accumulation of eosinophils in this disease. T-cell-derived interleukin 5 (IL-5) and autosecretion of IL-5 from activated eosinophils may be causative reasons for the extension and persistence of eosinophil inflammation. Objectives. To investigate whether eosinophils were accumulated and activated in nasal polyposis, and the roles of IL-5, eotaxin, and T cells in this process. Materials and methods. A retrospective study was conducted on 17 tissue samples from patients with nasal polyposis with allergy and 26 cases of non-allergic polyposis. Immunohistochemical staining by specific antibodies was carried out using the alkaline phosphatase anti-alkaline phosphatase method and the avidin-biotin complex technique.Results. The number of EG1-positive cells (pan eosinophil marker) was similar to the number of EG2-positive cells (activated eosinophil marker) in all tissue samples, although EG1- and EG2-positive cells were richer in allergic patients than those in non-allergic patients. Both EG1- and EG2-positive cells were correlated with CD3-positive cells (pan T cell marker) and IL-5-producing cells in allergic or non-allergic polyposis. A large proportion of IL-5 producing cells were eosinophils. Eotaxin protein was detected in all tissue samples and dominantly located in epithelial cells. Eotaxin expression between allergic and non-allergic subjects was not significantly different.  相似文献   

19.
ObjectivesSerum eosinophil percentage (SEP), eosinophil cationic protein (ECP) concentration, and total IgE (TIgE) concentration are known to increase in patients with allergic disease; however, the relevance of these elevated markers in children with negative allergic test results remains unclear. Therefore, this 2-year follow-up study aimed to investigate whether SEP, ECP concentration, and TIgE concentration are associated with an increased risk for allergic sensitization and allergic symptoms.MethodsIn 2012, SEP, ECP concentration, and TIgE concentration of third- and fourth-grade students from 6 elementary schools were measured. Skin prick test was performed, and the presence of allergic nasal symptoms was investigated using a questionnaire. In 2014, the same examinations were performed in the same set of students, who were then in the fifth and sixth grades, respectively, of the same schools. The cut-off value and usefulness of serologic markers (eosinophil count, ECP concentration, and TIgE concentration) were calculated using the receiver operating characteristic curve.ResultsSerum eosinophil percentage (cut-off value, 3.8%) was associated with the newly developed allergic nasal symptoms (sensitivity, 77.9; specificity, 41.8). A high serum TIgE concentration (cut-off value, 17.7 IU/mL) was also associated with the risk for allergic sensitization (sensitivity, 46.3; specificity, 85.3).ConclusionSEP and TIgE concentration were associated with the development of allergic symptoms and allergic sensitization, respectively, 2 years after the first examination.  相似文献   

20.
Protease and antiprotease activities were estimated in nasal secretions from patients with chronic sinusitis and nasal allergy, using [3H]-casein as substrate. In the purulent nasal secretions, strong protease activity was measured, but there was less activity in the allergic nasal secretions. In contrast, trypsin inhibitory activity in allergic nasal secretions was much higher than in nasal secretions from the patients with chronic sinusitis. A protease inhibitor was partially isolated from nasal secretions of the nasal allergic patients by Sephadex G-150 gel chromatography and characterized. This protease inhibitor has an apparent molecular weight of 10,000 D, determined by SDS-polyacrylamidegel electrophoresis. It depresses the activities of bovine pancreatic trypsin, bovine pancreatic chymotrypsin and proteases in nasal purulent secretions, whereas it does not inhibit porcine pancreatic elastase, papain, or human plasmin.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号