首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Background and Objectives:

Conversion to open surgery is an important problem, especially during the learning curve of laparoscopic totally extraperitoneal (TEP) inguinal hernia repair.

Methods:

Here, we discuss conversion to the Stoppa procedure during laparoscopic TEP inguinal hernia repair. Outcomes of patients who underwent conversion to an open approach during laparoscopic TEP inguinal hernia repair between September 2004 and May 2010 were evaluated.

Results:

In total, 259 consecutive patients with 281 inguinal hernias underwent laparoscopic TEP inguinal hernia repair. Thirty-one hernia repairs (11%) were converted to open conventional surgical procedures. Twenty-eight of 31 laparoscopic TEP hernia repairs were converted to modified Stoppa procedures, because of technical difficulties. Three of these patients underwent Lichtenstein hernia repairs, because they had undergone previous surgeries.

Conclusion:

Stoppa is an easy and successful procedure used to solve problems during TEP hernia repair. The Lichtenstein procedure may be a suitable option in patients who have undergone previous operations, such as a radical prostatectomy.  相似文献   

2.

Purpose

Total extraperitoneal preperitoneal (TEP) repair is widely used for inguinal, femoral, or obturator hernia treatment. However, mesh repair is not often used for strangulated hernia treatment if intestinal resection is required because of the risk of postoperative mesh infection. Complete mesh repair is required for hernia treatment to prevent postoperative recurrence, particularly in patients with femoral or obturator hernia.

Cases

We treated four patients with inguinocrural and obturator hernias (a 72-year-old male with a right indirect inguinal hernia; an 83-year-old female with a right obturator hernia; and 86- and 82-year-old females with femoral hernias) via a two-stage laparoscopic surgery. All patients were diagnosed with intestinal obstruction due to strangulated hernia. First, the incarcerated small intestine was released and then laparoscopically resected. Further, 8–24 days after the first surgery, bilateral TEP repairs were performed in all patients; the postoperative course was uneventful in all patients, and they were discharged 5–10 days after TEP repair. At present, no hernia recurrence has been reported in any patient.

Conclusion

The two-stage laparoscopic treatment is safe for treatment of strangulated inguinal, femoral, and obturator hernias, and complete mesh repair via the TEP method can be performed in elderly patients to minimize the occurrence of mesh infection.
  相似文献   

3.
Laparoscopic hernia repair is more difficult than open hernia repair. The totally extraperitoneal procedure with 3 trocars on the midline is more comfortable for the surgeon. We studied the impact of the length between the umbilicus and the pubis on the totally extraperitoneal procedure (95 hernias operated on in 70 patients). This length did not influence the totally extraperitoneal procedure in this study.

Background:

The laparoscopic repair of hernias is considered to be difficult especially for the totally extra-peritoneal technique (TEP) due to a limited working space and different appreciation of the usual anatomical landmarks seen through an anterior approach. The aim of our study has been to answer a question: does the umbilical-pubic distance, which influences the size of the mesh, affect the TEP technique used in the treatment of inguinal hernias?

Methods:

From January 2001 to May 2011, the umbilical-pubic (UP) distance was measured with a sterile ruler graduated in centimeters in all patients who underwent a symptomatic inguinal hernia by the TEP technique in two hernia surgery centers. The sex, age, BMI, hernia type, UP distance, operation time, hospital stay and complications were prospectively examined based on the medical records.

Results:

Seventy patients underwent 95 inguinal hernia repairs by the TEP technique. The umbilical-pubic distance average was 14 cm (10 to 22) and a 25 kg/m2 (16–30) average concerning the body mass index (BMI). Seventy percent of patients were treated on an outpatient basis. The postoperative course was very simple. There was no recurrence of hernia within this early postoperative period.

Conclusion:

The umbilical-pubic distance had no influence on the production of TEP with 3 trocars on the midline in this study.  相似文献   

4.

INTRODUCTION

Favourable short-term results, with respect to less postoperative pain and earlier return to physical activity, have been demonstrated with laparoscopic totally extraperitoneal (TEP) hernia repair compared with open mesh repair. However, there is limited data regarding long-term results.

PATIENTS AND METHODS

The study cohort consisted of 275 consecutive patients undergoing TEP repair between 1996 and 2002. Patient demographics, details of surgery, postoperative complications, recurrence and chronic pain were collected from patient records and from a prospective database. All patients were seen at 6 weeks and then annually for 5 years following surgery.

RESULTS

A total of 430 repairs were performed in the 275 patients (median age, 56 years; range, 20–94 years; men, 97.5%). Bilateral repair was performed in 168 patients (61.1%) and recurrent hernia repair in 79 patients (28.7%). Two patients were converted to an open procedure. Five-year follow-up was achieved in 72% of patients. Eleven patients (4%) died during the follow-up period due to unrelated causes. Hernia recurrence rate at 5 years was 1.1% per patient (three repairs). Recurrences were noted at 7 months, 2 years and 4 years following surgery. Chronic groin pain was reported by 21 patients (7.6%), seven of whom required referral to the pain team.

CONCLUSIONS

TEP hernia repair is associated with a recurrence rate of 1% at 5 years in this series. Chronic groin symptoms are also acceptably few. This recurrence rate following TEP repair compares extremely favourably with open mesh repair, particularly as it includes a high proportion of recurrent repairs. As well as the proven early benefits, TEP repair can be considered a safe and durable procedure with excellent long-term results.  相似文献   

5.

Background

Among endoscopic hernioplasties, totally extraperitoneal (TEP) and transabdominal preperitoneal (TAPP) approach are widely accepted alternatives to open surgery, both providing less postoperative pain, hospital length of stay and early return to work. Classical TEP technique requires three skin incisions for placement of three trocars in the midline or in triangulation.

Aim

To describe a technique using only two trocars for laparoscopic total extraperitoneal for inguinal hernia repair.

Method

Extraperitoneal access: place two regular trocars on the midline. The 10 mm is inserted into the subcutaneous in horizontal direction after a transverse infra-umbilical incision and then elevated at 60º angle. The 5 mm trocar is inserted at the same level of the pubis with direct vision. Preperitoneal space dissection: introduction 0º optical laparoscope through the infra-umbilical incision for visualization and preperitoneal dissection; insufflation pressure must be below 12 mmHg. Dissection of some anatomical landmarks: pubic bone, arcuate line and inferior epigastric vessels. Exposure of "triangle of pain" and "triangle of doom". Insertion through the 10 mm trocar polypropylene mesh of 10x15 cm to cover the hernia sites. Peritoneal sac and the dorsal edge of the mesh are repositioned in order to avoid bending or mesh displacement. It is also important to remember that the drainage is not necessary.

Results

The 2-port TEP required less financial costs than usual because it is not necessary an auxiliary surgeon to perform the technique. Trocars, suturing material and wound dressing were spared in comparison to the classical technique. Besides, there were only two incisions, which provides a better plastic result and less postoperative pain.

Conclusion

The TEP technique using two trocars is an alternative technique which improves cosmetic and financial outcomes.  相似文献   

6.

INTRODUCTION

Complex hernias continue to present a challenge. Surgical techniques for repair are carefully considered to reduce risk for complications. Laparoscopic repairs improve postoperative infection rates, and placement of biologic mesh decreases mesh infection rates. However, laparoscopic repairs using biologic mesh is generally challenging due to difficulty with maneuverability.

PRESENTATION OF CASE

We present a case of a complex ventral hernia that was laparoscopically repaired using a new FDA cleared laparoscopic biologic graft. The patient had multiple comorbidities, including obesity, hepatitis C, endocarditis secondary to IV drug use, tobacco smoking, bilateral inguinal hernia, and recurrent umbilical hernia. The recurrent hernia was larger, irreducible, and discolored compared to original defect. The patient underwent laparoscopic repair with primary closure and reinforcement with Strattice™ Tissue Matrix Laparoscopic (LifeCell Corporation, Branchburg, NJ). At nine months postoperative, the patient had no evidence of recurrence, infection, or chronic pain, demonstrating early success from the surgical management.

DISCUSSION

Presence of multiple comorbidities and incarcerated recurrent hernia increase risk for complications during and/or after hernia repair. Considering these factors, laparoscopic repair with Strattice Laparoscopic and defect closure was a reasonable technique for repair.

CONCLUSION

Laparoscopic suture repair reinforced with biologic dermal tissue matrix was successfully performed during a complex hernia repair.  相似文献   

7.

Background

Fixation of mesh is typically performed to minimize risk of recurrence in laparoscopic inguinal hernia repair. Mesh fixation with staples has been implicated as a cause of chronic inguinal pain. Our study aim is to compare mesh fixation using a fibrin sealant versus staple fixation in laparoscopic inguinal hernia and compare outcomes for hernia recurrence and chronic inguinal pain.

Methods and procedures

PubMed was searched through December 2010 by use of specific search terms. Inclusion criteria were laparoscopic total extraperitoneal repair inguinal hernia repair, and comparison of both mesh fibrin glue fixation and mesh staple fixation. Primary outcomes were inguinal hernia recurrence and chronic inguinal pain. Secondary outcomes were operative time, seroma formation, hospital stay, and time to return to normal activity. Pooled odds ratios (OR) were calculated assuming random-effects models.

Results

Four studies were included in the review. A total of 662 repairs were included, of which 394 were mesh fixed by staples or tacks, versus 268 with mesh fixed by fibrin glue. There was no difference in inguinal hernia recurrence with fixation of mesh by staples/tacks versus fibrin glue [OR 2.13; 95% confidence interval (CI) 0.60–7.63]. Chronic inguinal pain (at 3 months) incidence was significantly higher with staple/tack fixation (OR 3.25; 95% CI 1.62–6.49). There was no significant difference in operative time, seroma formation, hospital stay, or time to return to normal activities.

Conclusions

The meta-analysis does not show an advantage of staple fixation of mesh over fibrin glue fixation in laparoscopic total extraperitoneal inguinal hernia repair. Because fibrin glue mesh fixation with laparoscopic inguinal hernia repair achieves similar hernia recurrence rates compared with staple/tack fixation, but decreased incidence of chronic inguinal pain, it may be the preferred technique.
  相似文献   

8.

Purpose

Mesh fixation is essential in laparoscopic total extraperitoneal (TEP) repair of inguinal hernia; however, fixation sometimes causes post-operative pain. This study investigated a novel method of laparoscopic TEP repair without mesh fixation.

Methods

This study reviewed data from about two-hundred and forty-one laparoscopic TEP repairs on 219 patients, which were performed between December 2004 and October 2005.

Results

There were no statistically significant differences in the recurrence rate, seroma formation, and hospital stay. However, the mean operation time was shorter in the internal plug mesh group than the fixation group (p = 0.009), and post-operative pain only occurred in 4 cases in the internal plug mesh group in comparison to 29 cases in the mesh fixation group (p = 0.014).

Conclusions

An internal plug mesh without fixation might reduce post-operative pain after laparoscopic TEP repair of an inguinal hernia. Internal plug mesh without fixation may be an alternative method in laparoscopic TEP repair, especially for those involving indirect hernias.  相似文献   

9.

Objective

To determine the learning curve (number of operations required) to stabilize operating times and complication rates for a general surgeon doing laparoscopic inguinal hernia repair in a community practice.

Design

A prospective analysis.

Setting

A 256-bed secondary-care community hospital.

Patients

Ninety-eight consecutive patients booked for elective laparoscopic hernia repair on an outpatient basis.

Interventions

Using the transabdominal preperitoneal approach, 100 operations were carried out to repair 138 groins and a total of 164 separate hernial defects.

Outcome measures

The number of operations required to decrease operative times and complication rates to a steady level.

Results

There were no deaths. There were 5 conversions and 10 admissions, all occurring between the 1st and 46th operations. Two reoperations for reasons other than recurrence were required between the 45th and 55th operations. There were 24 other complications. Complications and surgical times began to level off after 50 operations. The 1 readmission was after the 42nd operation. There were 4 recurrences (2.9% recurrence rate), 2 in each group of 50 operations. Both groups of 2 recurrences occurred within the first 10 operations involving the use of a new stapler. Twenty-two other patients had open hernia repairs because laparoscopy was unsuitable for them.

Conclusion

The learning curve for laparoscopic inguinal hernia repair in the hands of a general surgeon in community practice who is experienced in open herniorraphy and laparoscopic cholecystectomy is at least 50 operations.  相似文献   

10.

Background and Objectives:

To investigate the prevalence, diagnosis, clinical significance, and treatment strategies for bulging in the area of laparoscopic repair of ventral hernia that is caused by mesh protrusion through the hernia opening, but with intact peripheral fixation of the mesh and actually a still sufficient repair.

Methods:

Medical records of all 765 patients who underwent laparoscopic ventral hernia repair were reviewed, and all patients with a swelling in the repaired area were identified and analyzed.

Results:

Twenty-nine patients were identified. They all underwent a computed tomography assessment. Seventeen patients (2.2% of the total group) had a hernia recurrence; in an additional 12 patients (1.6%), radiologic examinations indicated only bulging of the mesh but no recurrence. Bulging was associated with pain in 4 patients who underwent relaparoscopy and got a new, larger mesh tightly stretched over the entire previous repair. Eight asymptomatic patients decided on “watchful waiting.” All patients remained symptom free during a median follow-up of 22 months.

Conclusion:

Symptomatic bulging, though not a recurrence, requires a new repair and must be considered as an important negative outcome of laparoscopic ventral hernia repair. In asymptomatic patients, “watchful waiting” seems justified.  相似文献   

11.

INTRODUCTION

Synthetic mesh is the prosthetic material used for most inguinal hernioplasties. However, when left in contact with intra-abdominal viscera, it often becomes associated with infection and migration, particularly in irradiated tissues, contaminated fields, immunosuppressed individuals, and patients with intestinal obstruction or fistula. AlloDerm® Regenerative Tissue Matrix (LifeCell Corporation, Branchburg, NJ) is derived from human cadaver skin and may be associated with fewer visceral adhesions and more durability in infected fields than synthetic mesh.

PRESENTATION OF CASE

We report the first case in which AlloDerm was used in a laparoscopic transabdominal preperitoneal repair of a multiple recurrent right inguinal hernia, a left femoral hernia, and an umbilical hernia in the same patient. Use of AlloDerm greatly enhanced the maneuverability during laparoscopic hernia repair due to its pliability and strength and eliminated the need to cover the prosthetic with peritoneum.

DISCUSSION

Previous pelvic radiation and multiple previous groin repairs can render the peritoneum friable, resulting in obstacles to successful closure. AlloDerm is a reasonable choice for groin hernia repairs when such factors are present.

CONCLUSION

The long-term durability of AlloDerm for laparoscopic groin hernia repairs is yet to be determined, but based on current data it seems prudent to use this technique in laparoscopic repair of complex groin hernias where infection is suspected or inadequate prosthetic coverage with peritoneum is anticipated.  相似文献   

12.

Background:

Inguinal hernia repair is the most common procedure in general surgery and 80,000 operations are performed annually in Great Britain, 100,000 in France and 700,000 in the US. Given its high frequency has a major impact, both in the medical and economic aspects.

Aim:

Analyze the immediate postoperative complications comparing mesh versus non mesh hernioplasty.

Method:

Randomized control trial, with the enrollment of 263 patients underwent surgery for inguinal hernia randomized by randomization table. Treatment (mesh, Lichtenstein or without mesh, Bassini technique) was assigned using sequentially numbered opaque envelopes having fulfilled the inclusion criteria. The variables analyzed were: postoperative pain, seroma, hematoma, infection, return to normal activities and recurrence.

Results:

The mean age was 55.5 years, 88% patients were male and 12% female. The pain was higher in patients operated with mesh.

Conclusions:

The inguinal hernia repair mesh group had less immediate postoperative complications and significantly earlier return to work than hernioplasty without mesh, this being one of the most important conclusions.  相似文献   

13.

Background

Theoretically, a lighter and softer mesh may decrease nerve entrapment and chronic pain by creating less fibrosis and mesh contracture in laparoscopic inguinal hernia repair.

Methods

We performed a telephone survey of patients who underwent laparoscopic inguinal hernia surgery between 2001 and 2007. We recorded patient responses for chronic pain, foreign body sensation, recurrence, satisfaction, and return to work, and then studied the effect of type of mesh (polypropylene vs polyester) on these factors.

Results

Of 109 consecutive patients surveyed (mean age, 54.5 y), 67 eligible patients underwent 84 transabdominal extraperitoneal procedures and 2 transabdominal preperitoneal procedures. Patients with polypropylene mesh had a 3 times higher rate of chronic pain (P = .05), feeling of lump (P = .02), and foreign body perception (P = .05) than the polyester mesh group. Our overall 1-year recurrence rate was 5.9%. The recurrence rate was 9.3% for the polypropylene group and 2.9% for the polyester group (P = .26).

Conclusions

A lightweight polyester mesh has better long-term outcomes for chronic pain and foreign body sensation compared with a heavy polypropylene mesh in laparoscopic inguinal hernia repair. We also saw a trend toward higher recurrence in the polypropylene group.  相似文献   

14.

Background

The aim of this study is to evaluate the most cost-effective treatment strategy using preperitoneal mesh for patients with recurrent inguinal hernia. Currently, the issue of cost-effectiveness is entirely unresolved.

Methods

A decision analysis was carried out based on the results of a systematic literature review of articles concerning recurrent inguinal hernia repair that were published between 1979 and 2011. A virtual cohort was programmed to undergo three different treatment procedures: (1) laparoscopic totally extraperitoneal hernia repair (TEP), (2) open preperitoneal mesh repair according to Stoppa, and (3) open preperitoneal mesh repair according to Nyhus. We carried out a base-case analysis and varied all variables over a broad range of reasonable hypotheses in multiple one-way and two-way sensitivity analyses.

Results

The average cost-effectiveness ratio of Nyhus, Stoppa, and TEP per quality-adjusted life year was US $ ($)1,942, $1,948, and $2,011, respectively. In terms of the incremental cost-effectiveness ratio (ICER), Stoppa was dominated. The choice between TEP or Nyhus procedure depends on the combination of a specific center’s rates of recurrence and morbidity as disclosed by three-way sensitivity analysis.

Conclusions

Nyhus and TEP repairs are possible optimal choices depending primarily on the institution’s rates of recurrence and morbidity. Based on our net benefit-related decision analysis, a hypothetical “fixed budget trade-off” suggests potential annual incremental health system cost savings of $200,000 attained by shifting care for 1,000 patients from TEP to Nyhus repair (depending on clinical end-points, which is a decisive factor).  相似文献   

15.

Introduction:

Both polyester composite (POC) and polytetrafluoroethylene (PTFE) mesh are commonly used for laparoscopic ventral hernia repair. However, sparse information exists comparing perioperative and long-term outcome by mesh repair.

Methods:

A prospective database was utilized to identify 116 consecutive patients who underwent laparoscopic ventral hernia repair at The Mount Sinai Hospital from 2004-2009. Patients were grouped by type of mesh used, PTFE versus POC, and retrospectively compared. Follow-up at a mean of 12 months was achieved by telephone interview and office visit.

Results:

Of the 116 patients, 66 underwent ventral hernia repair with PTFE and 50 with POC mesh. Patients were well matched by patient demographics. No difference in mean body mass index (BMI) was demonstrated between the PTFE and POC group (31.8 vs. 32.5, respectively; P=NS). Operative time was significantly longer in the PTFE group (136 vs.106 minutes, P<.002). Two perioperative wound infections occurred in the PTFE group and none in the POC group (P=NS). No other major complications occurred in the immediate postoperative period (30 days). At a mean follow-up of 12 months, no significant difference was demonstrated between the PTFE and POC groups in hernia recurrence (3% vs. 2%), wound complications (1% vs. 0%), mesh infection, requiring removal (3% vs. 0%), bowel obstruction (3% vs. 2%), or persistent pain or discomfort (28% vs. 32%), respectively (P=NS).

Conclusion:

Our study demonstrated no significant association between types of mesh used and postoperative complications. In the 12-month follow-up, no differences were noted in hernia recurrence.  相似文献   

16.

Background

Laparoscopic totally extraperitoneal (TEP) repair has been accepted as a popular procedure for inguinal hernia repair, but surgeons still encounter technical difficulties owing to unfamiliar pelvic anatomy and limited working space. We sought to estimate the learning curve for laparoscopic TEP repair without supervision.

Methods

We retrospectively analyzed the medical records of patients scheduled for laparoscopic TEP repair of an inguinal hernia from December 2000 to October 2007.

Results

We reviewed medical records for 700 patients. The cases were divided into 8 groups: 20 patients each in groups I–V and 200 patients each in groups VI–VIII. No significant difference in demographic characteristics was identified among the groups. The mean duration of surgery significantly decreased (p < 0.001) in relation to experience; it reached a plateau of less than 30 minutes (mean 28 min) after 60 cases. The mean length of stay in hospital was 0.97 days, reaching a plateau after 20 cases. Six patients were converted to other techniques: 1 patient each in groups III and VIII and 4 patients in group VII. Three recurrences were detected; however, 2 were excluded because the patient had bilateral inguinal hernias.

Conclusion

We estimate the learning curve for laparoscopic TEP repair is 60 cases for a beginner surgeon. The presence of an experienced supervisor during the first 60 cases can help prevent unnecessary complications and shorten the duration of surgery.  相似文献   

17.

Background and Objectives:

Mesh fixation during laparoscopic totally extraperitoneal repair is thought to be necessary to prevent recurrence. However, mesh fixation may increase postoperative chronic pain. This study aimed to describe the experience of a single surgeon at our institution performing this operation.

Methods:

We performed a retrospective review of the medical records of all patients who underwent bilateral laparoscopic totally extraperitoneal repair without mesh fixation for inguinal hernia from January 2005 to December 2011. Demographic, operative, and postoperative data were obtained for analysis.

Results:

A total of 343 patients underwent simultaneous bilateral laparoscopic totally extraperitoneal repair of 686 primary and recurrent inguinal hernias from January 2005 to December 2011. The mean operative time was 33 minutes. One patient was converted to an open approach (0.3%), and 1 patient had intraoperative bladder injury. Postoperative hematoma/seroma occurred in 5 patients (1.5%), wound infection in 1 (0.3%), hematuria in 2 (0.6%), and acute myocardial infarction in 1 (0.3%). Chronic pain developed postoperatively in 9 patients (2.6%); 3 of them underwent re-exploration. All patients were discharged home a few hours after surgery except for 3 patients. Among the 686 hernia repairs, there were a total of 20 recurrences (2.9%) in 18 patients (5.2%). Two patients had bilateral recurrences, whereas 16 had unilateral recurrences. Twelve of the recurrences occurred after 1 year (60%). Fourteen recurrences occurred among direct hernias (70%).

Conclusion:

Compared with the literature, our patients had fewer intraoperative and postoperative complications, less chronic pain, and no increase in operative time or length of hospital stay but had a slight increase in recurrence rate.  相似文献   

18.

Background

Hernia repair is one of the most common surgical procedures, and some patients suffer from chronic pain after hernia surgery. The aim of the present study was to evaluate chronic postherniorrhaphy pain in men who underwent Lichtenstein mesh repair or preperitoneal (posterior) repair.

Methods

Our study included 94 male inpatients. Two surgeons experienced in both Lichtenstein and preperitoneal hernia repair performed the procedures. We controlled postoperative pain with systemic analgesic therapy. We evaluated the patients over the subsequent 12 months, using a questionnaire to focus on chronic pain and its limitations to their quality of life.

Results

The overall incidence of chronic pain at 2 months was 5%. About 6% of patients who underwent Lichtenstein repair (n = 70) and 4% of patients who underwent preperitoneal repair (n = 24) experienced chronic pain. All patients with chronic pain rated their pain as slight or moderate. Their pain was present occasionally and was related to physical stress. None of the patients were unable to work. After 12 months of follow-up, the overall incidence of chronic pain decreased to 3%, with 3 patients in Lichtenstein group reporting chronic pain with slight limitations in sports and social activities.

Conclusion

The incidence rates of chronic pain after Lichtenstein and preperitoneal repair were 6% and 4%, respectively. Inpatient status might have resulted in low incidences with both approaches.  相似文献   

19.
20.

Objective:

Review of international literature reveals eight reported cases of laparoscopic obturator hernia repair. Non-specific signs and symptoms make the diagnosis of an obturator hernia difficult. Laparoscopic intervention provides a minimally invasive method to simultaneously diagnose and repair these hernias.

Methods and Procedures:

A 35 year old woman presented with lower abdominal pain, vaginal bleeding, and dyspareunia. During gynecological diagnostic laparoscopy, a pelvic floor hernia was suspected, and a general surgical evaluation was sought. At a subsequent laparoscopy, the diagnosis of a left direct inguinal and a right obturator hernia was made. Both were repaired laparoscopically with polypropylene mesh.

Results:

At follow-up at one and six weeks postoperatively, the patient''s complaints of pain had completely resolved.

Conclusion:

The diagnosis of obturator hernia is problematic. The usual presenting signs and symptoms are non-specific. Without conclusive historical or physical findings, laparoscopy is an excellent method for diagnosing obturator hernia. This entity, once diagnosed laparoscopically, can be repaired simultaneously via laparoscopic mesh technique.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏