首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

PURPOSE

The aim of this study was to evaluate whether the push-out bond strength varies between oval and circular fiber posts, and to examine the effect on the resin cement thicknesses around the posts.

MATERIALS AND METHODS

Eighteen mandibular premolar roots were separated into two groups for oval and circular fiber posts systems. Post spaces were prepared and fiber posts were luted to the post spaces. Roots were cut horizontally to produce 1-mm-thick specimens. Resin cement thicknesses were determined with a metallographic optical microscope and push-out tests were done.

RESULTS

No significant differences were observed in terms of push-out bond strength between the oval and circular fiber posts (P>.05) The resin cement thicknesses of the oval posts were greater than those of the circular posts group in the coronal, middle and apical specimens (P<.05).

CONCLUSION

In the light of these results, it can be stated that resin cement thickness does not affect the push-out bond strength.  相似文献   

2.

PURPOSE

Over the past years, the adhesion of fiber posts luted with simplified adhesive systems has been a matter of great interest. The aim of this study was to assess the post retentive potential of a self-adhesive resin cement using different adhesive systems to compare the push-out bond strengths of fiber posts.

MATERIALS AND METHODS

The post spaces of 56 mandibular premolar roots were prepared and divided into 4 experimental groups and further divided into 2 subgroups according to testing time (n=7). The fiber posts (Rely X Fiber Post) were luted with a self-adhesive resin cement (RelyX Unicem) and one of the following adhesive systems: no adhesive, a total-etch adhesive resin (Single Bond), a two-step self-etch adhesive resin (Clearfil SE Bond) and a one-step self-etch adhesive resin (Clearfil S3 Bond). Each root was cut horizontally, and 1.5 mm thick six root segments were prepared. Push-out tests were performed after one week or three months (0.5 mm/min). Statistical analysis were performed with three-way ANOVA (α=.05).

RESULTS

Cervical root segments showed higher bond strength values than middle segments. Adhesive application increased the bond strength. For one week group, the total-etch adhesive resin Single Bond showed higher bond strength than the self-adhesive resin cement RelyX Unicem applied without adhesive resin at middle region. For 3 months group, the two-step self-etch adhesive resin Clearfil SE Bond showed the highest bond strength for both regions. Regarding the time considered, Clearfil SE Bond 3 months group showed higher bond strength values than one week group.

CONCLUSION

Using the adhesive resins in combination with the self-adhesive resin cement improves the bond strengths. The bond strength values of two-step self-etch adhesive resin Clearfil SE Bond improved as time passes.  相似文献   

3.
One of the clinically relevant problems dentists face when restoring endodontically treated teeth is the mismatch between fiber post and post space diameters, which results in an excessively thick resin cement layer. Fiber post relining appears as a solution for this problem.

Objectives:

The aim of this study was to evaluate the effect of fiber post relining with composite resin on push-out bond strength.

Material and Methods:

Twenty bovine incisors were selected to assess post retention. The crowns were removed below the cementoenamel junction and the root canals were treated endodontically and flared with diamond burs. The roots were allocated into two groups (n=10): G1: fiber posts without relining and G2: fiber posts relined with composite resin. The posts were cemented with a dual-cured resin cement and the specimens were sectioned transversally. Three 1.5-mm thick slabs were obtained per root and identified as cervical, medium and apical thirds. The push-out test was performed at a crosshead speed of 0.5 mm/min until post dislodgement occurred. The failure mode of fractured specimens was analyzed under scanning electron microscopy. Data were analyzed by split-plot ANOVA and post-hoc Tukey''s test at a pre-set alpha of 0.05.

Results:

Relined fiber posts presented higher retention values than non-relined post in all thirds. No statistically significant differences (p>0.05) were found among thirds for relined posts. All failures occurred at the interface between resin cement and root dentin.

Conclusions:

Relining with composite resin seems to be an effective method to improve the retention of fiber posts to flared root canals.  相似文献   

4.

Objective

This study utilizes micro-CT image combined with finite element (FE) analysis and in vitro fatigue testing to investigate the mechanical behavior associating with early resin luting cement damage induced by voids around a circular fiber post in a root canal treated premolar.

Methods

Six similar mandibular first premolars with root canal treatment were scanned with high resolution micro-CT before and after fatigue testing. Micro-CT images of all teeth were processed to identify various materials (dentin, luting cement and void) to evaluate the volume/position of the void in each reconstructed tooth root canal model. Six corresponding mesh models from CT images were generated to perform FE simulations under receiving oblique concentrated loads (200 N) to evaluate the luting cement layer mechanical behavior. All teeth were subjected to the fatigue test with 240,000 load cycles simulating chewing for one year to compare results with those in FE simulations.

Results

The result showed that most voids occurred adjacent to the apical third of the fiber post. Voids induced the fiber post to pull out, creating a stress concentration at the void boundary. Fatigue life in the experimental testing was found decreased with the stress value/micro-motion increasing in FE analysis.

Significance

This study establishes that micro-CT, FE simulation and fatigue testing can be integrated to understand the early de-bonding mechanism at the luting cement layer in a root canal treated premolar, suggesting that attention must be paid to resin luting cement dissolving/debonding easier when voids occur in the apical and peri-apical areas of fiber posts.  相似文献   

5.

Objectives

The purpose of the study was to evaluate by micro-computerized tomography (microCT) areas and volumes of post, cement, and voids/bubbles in the post space of oval-shaped premolars restored either with oval or circular posts.

Materials and methods

Twelve extracted premolars were divided into two groups according to the drill-fiber post system used: (1) GC Fiber Post Drill?+?circular post GC Fiber Post; (2) Ellipson tipTM?+?oval post Ellipson postTM. Each tooth was scanned using microCT, and areas and volumes of canal, post space, post, cement, and voids at coronal, medium, and apical level were calculated by using a three-dimensional visualization software. Two-way analyses of variance and Tukey tests were used for statistical analysis (p?<?0.05).

Results

The area of voids was significantly greater at apical level of oval posts, but no difference was found between the levels among the groups. Regardless of post shape, the volume of voids and of cement was significantly higher at the coronal level. With oval posts, the total volume of cement was twice as much as with circular posts, and the difference was statistically significant.

Conclusions

Our results indicate that the volume of voids does not depend on post shape. Moreover, the microCT analysis demonstrated that the volume of cement was greater with oval posts compared to circular posts.

Clinical relevance

The microCT analysis provided interesting information on voids distribution and on the ratio between post shape and cement thickness. These results might address the clinician in the reconstruction of teeth with fiber posts.  相似文献   

6.

Objective

The purpose of this study was to assess the push-out bond strength of glass fiber posts to root dentin after cementation with glass ionomer (GICs) and resin-modified glass ionomer cements (RMGICs).

Material and Methods

Fifty human maxillary canines were transversally sectioned at 15 mm from the apex. Canals were prepared with a step back technique until the application of a #55 K-file and filled. Post spaces were prepared and specimens were divided into five groups according to the cement used for post cementation: Luting & Lining Cement; Fuji II LC Improved; RelyX Luting; Ketac Cem; and Ionoseal. After cementation of the glass fiber posts, all roots were stored at 100% humidity until testing. For push-out test, 1-mm thick slices were produced. The push-out test was performed in a universal testing machine at a crosshead speed of 0.5 mm/minute and the values (MPa) were analyzed by Kolmogorov-Smirnov and Levene''s tests and by two-way ANOVA and Tukey''s post hoc test at a significance level of 5%.

Results

Fiber posts cemented using Luting & Lining Cement, Fuji II LC Improved, and Ketac Cem presented the highest bond strength to root dentin, followed by RelyX Luting. Ionoseal presented the lowest bond strength values (P>0.05). The post level did not influence the bond strength of fiber posts to root dentin (P=0.148). The major cause of failure was cohesive at the cement for all GICs and RMGICs.

Conclusions

Except for Ionoseal, all cements provided satisfactory bond strength values.  相似文献   

7.

Purpose

The purpose of the study was to evaluate the effect of clenching tasks on the stress and strain of condylar osteosynthesis screws and plates, as well as on the stress, strain distribution and displacement on the whole mandible and bone surrounding screws.

Methods

Three-dimensional finite element models of the mandible, two straight four-hole plates and eight screws were established. Six static clenching tasks were simulated in this study: incisal clench (INC), intercuspal position (ICP), right unilateral molar clench (RMOL), left unilateral molar clench (LMOL), right group function (RGF) and left group function (LGF).

Results

Based on the simulation of the six clenching tasks, none of the inserted screws and plates were broken or bended. For the whole mandibular bone, the maximum von Mises stress and von Mises strain observed were yielded by the ICP. For the bone surrounding the inserted screws, the maximum von Mises stress and von Mises strain were yielded by the LMOL (49.2 MPa and 3795.1 μ).

Conclusion

Clenching tasks had significant effects on the stress distribution on the condylar osteosynthesis and the bone surrounding screws. Contralateral occlusion task (LMOL) had the maximal results of von Mises stress and strain and healing problems could be occur, this result confirms the importance of soft diet after surgery.
  相似文献   

8.

Objective

The aim of the present study was to analyze the influence of root canal and glass fiber post diameters on the biomechanical behavior of the dentin/cement/post interface of a root-filled tooth using 3D finite element analysis.

Material and Methods

Six models were built using micro-CT imaging data and SolidWorks 2007 software, varying the root canal (C) and the glass fiber post (P) diameters: C1P1-C=1 mm and P=1 mm; C2P1-C=2 mm and P=1 mm; C2P2-C=2 mm and P=2 mm; C3P1-C=3 mm and P=1 mm; C3P2-C=3 mm and P=2 mm; and C3P3-C=3 mm and P=3 mm. The numerical analysis was conducted with ANSYS Workbench 10.0. An oblique force (180 N at 45º) was applied to the palatal surface of the central incisor. The periodontal ligament surface was constrained on the three axes (x=y=z=0). Maximum principal stress (σmax) values were evaluated for the root dentin, cement layer, and glass fiber post.

Results:

The most evident stress was observed in the glass fiber post at C3P1 (323 MPa), and the maximum stress in the cement layer occurred at C1P1 (43.2 MPa). The stress on the root dentin was almost constant in all models with a peak in tension at C2P1 (64.5 MPa).

Conclusion

The greatest discrepancy between root canal and post diameters is favorable for stress concentration at the post surface. The dentin remaining after the various root canal preparations did not increase the stress levels on the root.  相似文献   

9.

PURPOSE

This study was accomplished to assess the biomechanical state of different retaining methods of bar implant-overdenture.

MATERIALS AND METHODS

Two 3D finite element models were designed. The first model included implant overdenture retained by Hader-clip attachment, while the second model included two extracoronal resilient attachment (ERA) studs added distally to Hader splint bar. A non-linear frictional contact type was assumed between overdentures and mucosa to represent sliding and rotational movements among different attachment components. A 200 N was applied at the molar region unilaterally and perpendicular to the occlusal plane. Additionally, the mandible was restrained at their ramus ends. The maximum equivalent stress and strain (von Mises) were recorded and analyzed at the bone-implant interface level.

RESULTS

The values of von Mises stress and strain of the first model at bone-implant interface were higher than their counterparts of the second model. Stress concentration and high value of strain were recognized surrounding implant of the unloaded side in both models.

CONCLUSION

There were different patterns of stress-strain distribution at bone-implant interface between the studied attachment designs. Hader bar-clip attachment showed better biomechanical behavior than adding ERA studs distal to hader bar.  相似文献   

10.

Objective

The aims of this study were to compare different surgical approaches to rapid canine retraction by designing and selecting the most effective method of reducing resistance by a three-dimensional finite element analysis.

Material and Methods

Three-dimensional finite element models of different approaches to rapid canine retraction by reducing resistance and distraction were established, including maxillary teeth, periodontal ligament, and alveolar. The models were designed to dissect the periodontal ligament, root, and alveolar separately. A 1.5 N force vector was loaded bilaterally to the center of the crown between first molar and canine, to retract the canine distally. The value of total deformation was used to assess the initial displacement of the canine and molar at the beginning of force loading. Stress intensity and force distribution were analyzed and evaluated by Ansys 13.0 through comparison of equivalent (von Mises) stress and maximum shear stress.

Results

The maximum value of total deformation with the three kinds of models occurred in the distal part of the canine crown and gradually reduced from the crown to the apex of the canine; compared with the canines in model 3 and model 1, the canine in model 2 had the maximum value of displacement, up to 1.9812 mm. The lowest equivalent (von Mises) stress and the lowest maximum shear stress were concentrated mainly on the distal side of the canine root in model 2. The distribution of equivalent (von Mises) stress and maximum shear stress on the PDL of the canine in the three models was highly concentrated on the distal edge of the canine cervix.

Conclusions

Removal of the bone in the pathway of canine retraction results in low stress intensity for canine movement. Periodontal distraction aided by surgical undermining of the interseptal bone would reduce resistance and effectively accelerate the speed of canine retraction.  相似文献   

11.

Statement of problem

Pertinent evidence regarding the mechanical integrity of mandibular anterior teeth restored with a post-and-core is limited.

Purpose

The purpose of this finite element analysis study was to compare the impact of the post type (glass fiber post-and-resin core or cast post-and-core) along with the ferrule effect on the stress fields generated in endodontically treated mandibular lateral incisors and canines.

Material and methods

Three-dimensional models of the segmented mandible were developed. Mandibular incisors and canines with or without a 2-mm circular ferrule and restored with a cast post-and-core or glass fiber post-and-resin core were simulated and subjected to linear elastic static analysis. The principal stress values were calculated. von Mises equivalent stresses were used to evaluate the stress.

Results

Maximum principal stresses in dentin were highest in incisors, with a ferrule. Stress parameters in composite resin core in both incisors and canines were critically close to the tensile failure limit of the core material. Cast post-and-cores cemented in incisors without a ferrule accumulated the highest stresses, exceeding the tensile failure limit of resin-modified glass ionomer cement.

Conclusions

Tooth preparation with a ferrule led to a remarkable rise in stress in the dentin of mandibular incisors but favored the mechanical integrity of the restoration.  相似文献   

12.

PURPOSE

Numerous methods were used to etch the fiber posts to improve its bonding to root canal dentin. Our aim was to evaluate the efficacy of 37% phosphoric acid in etching fiber posts in comparison with 24% hydrogen peroxide.

MATERIALS AND METHODS

Ninety human maxillary central incisors were taken and post space preparation was done. Ninety fiber posts were taken and divided into three groups (n=30) based on the surface treatment they received (H3PO4, H2O2, distilled water) and each group was further divided (n=10) based on the time period of application (15 seconds, 30 seconds, 60 seconds). All the posts were luted into canals using Rely X UniCem-2. Each tooth was then sectioned into six slices and subjected to push out test. Data obtained was subjected to statistical analysis at P<.05. The surface topography was evaluated using scanning electron microscopy.

RESULTS

Highest bond strength values were noted in 15 seconds etched phosphoric acid group and 60 seconds etched hydrogen peroxide group with no significant difference between two groups. Surface topography revealed complete epoxy layer removal with no damage to its structural integrity in those groups.

CONCLUSION

H3PO4 etching for a period of 15 seconds is an effective alternative in improving the adhesion of fiber post to root dentin.  相似文献   

13.

Statement of problem

Narrow diameter implants were developed to allow placement in narrow alveolar ridges. Clinicians may have concerns about the durability and function of such implants.

Purpose

The purpose of this finite element study was to compare the stress values occurring on the implant and at the implant bone interface after the application of the static and dynamic forces on narrow diameter, titanium and titanium-zirconia implants in the maxillary and mandibular second premolar region.

Material and methods

Titanium (Ti) and titanium-zirconium (Ti-Zr) narrow diameter implants (3.3 mm in diameter, 10 mm in length) were simulated in the maxillary and mandibular second premolar region, and metal-ceramic crown restorations were designed. Forces of 100 N were applied to crowns in a vertical and oblique (45-degree angle to the long axis) direction. Maximum and minimum principal stresses in the cortical and trabecular bone and the von Mises stresses and fatigue strength of the implants were evaluated with 3-dimensional finite element analysis.

Results

In vertical and oblique static loading, Ti and Ti-Zr implants showed similar stress distribution within the same jaw models. However, the von Mises stresses in Ti-Zr implants were slightly higher than for Ti implants in all models. In oblique static and dynamic loading, all stresses were found higher than vertical loading, and fatigue failure results were found to be more critical than vertical forces.

Conclusions

Based on a numerical simulation, Ti and Ti-Zr alloys can be used successfully as narrow diameter implants in the second premolar area.  相似文献   

14.

PURPOSE

The purpose of this study was to compare stress distributions of implant-supported crown placed in fibula bone model with those in intact mandible model using three-dimensional finite element analysis.

MATERIALS AND METHODS

Two three-dimensional finite element models were created to analyze biomechanical behaviors of implant-supported crowns placed in intact mandible and fibula model. The finite element models were generated from patient''s computed tomography data. The model for grafted fibula was composed of fibula block, dental implant system, and implant-supported crown. In the mandible model, same components with identical geometries with the fibula model were used except that the mandible replaced the fibula. Vertical and oblique loadings were applied on the crowns. The highest von Mises stresses were investigated and stress distributions of the two models were analyzed.

RESULTS

Overall stress distributions in the two models were similar. The highest von Mises stress values were higher in the mandible model than in the fibula model. In the individual prosthodontic components there was no prominent difference between models. The stress concentrations occurred in cortical bones in both models and the effect of bicortical anchorage could be found in the fibula model.

CONCLUSION

Using finite element analysis it was shown that the implant-supported crown placed in free fibula graft might function successfully in terms of biomechanical behavior.  相似文献   

15.

PURPOSE

The aim of the present study was to assess the effect of ascorbic acid, ethanol and acetone on microtensile bond strength between fiber posts pre-treated with hydrogen peroxide and composite resin cores.

MATERIALS AND METHODS

Twenty four fiber posts were pre-treated with 24% hydrogen peroxide and divided into 4 groups as follows: G1: no treatment, as control group; G2: treatment with 10% ascorbic acid solution for 5 minutes; G3: treatment with 70% ethanol solution for 5 minutes; and G4: treatment with 70% acetone solution for 5 minutes. Each fiber post was surrounded by a cylinder-shaped polyglass matrix which was subsequently filled with composite resin. Two sections from each sample were selected for microtensile test at a crosshead with speed of 0.5 mm/min. Statistical analyses were performed using one-way ANOVA and a post hoc Tukey HSD test. Fractured surfaces were observed under a stereomicroscope at ×20 magnification. The fractured surfaces of the specimens were observed and evaluated under a SEM.

RESULTS

Means of microtensile bond strength values (MPa) and standard deviations in the groups were as follows: G1: 9.70±0.81; G2: 12.62±1.80; G3: 16.60±1.93; and G4: 21.24±1.95. G4 and G1 had the highest and the lowest bond strength values, respectively. A greater bond strength value was seen in G3 compared to G2. There were significant differences between all the groups (P<.001). All the failures were of the adhesive mode.

CONCLUSION

Application of antioxidant agents may increase microtensile bond strength between fiber posts treated with hydrogen peroxide and composite cores. Acetone increased bond strength more than ascorbic acid and ethanol.  相似文献   

16.

Introduction

The aim of this study was to evaluate the influence of post system, length, and ferrule on biomechanical behavior of endodontically treated anterior teeth.

Methods

The investigation was conducted by using laboratory tests and 3-dimensional finite element analysis. Eighty bovine incisors were selected and divided into 8 treatment groups (n = 10) with absence of ferrule and 2.0 mm of ferrule, restored with glass fiber post or cast post and core, and 12.0 and 7.0 mm of post length. The specimens were loaded at 135° angle, and the strain was measured by using strain gauge method. Specimens were subsequently loaded until fracture. Strain and fracture resistance results were analyzed by 3-way analysis of variance and Tukey honestly significant difference tests (α = 0.05). Three-dimensional models of a maxillary central incisor were generated with the same treatment variations used in laboratory tests. Each model was subjected to 100 N oblique loads. Results were evaluated by von Mises criterion.

Results

Ferrule was a determining factor in the strain, fracture resistance, and fracture pattern. In the absence of ferrule, the use of fiberglass posts represents a conservative choice from the standpoint of the fracture patterns observed. The length of 7 mm for cast post and cores produced high rates of root fractures. Finite element analysis showed that glass fiber post showed homogeneous stress distribution, whereas cast post showed stress concentration into root canal.

Conclusions

Post length influenced only the cast post strain and stress distribution. The ferrule groups always showed more satisfactory stress distribution and fracture resistance.  相似文献   

17.

PURPOSE

Debonding of a composite resin core of the fiber post often occurs at the interface between these two materials. The aim of this study was to evaluate the effects of different surface treatment methods on bond strength between fiber posts and composite core.

MATERIALS AND METHODS

Sixty-four fiber posts were picked in two groups (Hetco and Exacto). Each group was further divided into four subgroups using different surface treatments: 1) silanization; 2) sandblasting; 3) Treatment with 24% H2O2, and 4) no treatment (control group). A cylindrical plexiglass matrix was placed around the post and filled with the core resin composite. Specimens were stored in 5000 thermal cycles between 5℃ and 55℃. Tensile bond strength (TBS) test and evaluation using stereomicroscope were performed on the specimen and the data were analyzed using two-way ANOVA, Post Hoc Scheffe tests and Fisher''s Exact Test (α=.05).

RESULTS

There was a significant difference between the effect of different surface treatments on TBS (P<.001) but different brands of post (P=.743) and interaction between the brand of post and surface treatment (P=.922) had no significant effect on TBS. Both silanization and sandblasting improved the bonding strength of fiber posts to composite resin core, but there were not any significant differences between these groups and control group.

CONCLUSION

There was not any significant difference between two brands of fiber posts that had been used in this study. Although silanization and sandblasting can improve the TBS, there was not any significant differences between surface treatments used.  相似文献   

18.

Objective

This study evaluated, in vitro, the fracture resistance of human non-vital teeth restored with different reconstruction protocols.

Material and methods

Forty human anterior roots of similar shape and dimensions were assigned to four groups (n=10), according to the root reconstruction protocol: Group I (control): non-weakened roots with glass fiber post; Group II: roots with composite resin by incremental technique and glass fiber post; Group III: roots with accessory glass fiber posts and glass fiber post; and Group IV: roots with anatomic glass fiber post technique. Following post cementation and core reconstruction, the roots were embedded in chemically activated acrylic resin and submitted to fracture resistance testing, with a compressive load at an angle of 45º in relation to the long axis of the root at a speed of 0.5 mm/min until fracture. All data were statistically analyzed with bilateral Dunnett''s test (α=0.05).

Results

Group I presented higher mean values of fracture resistance when compared with the three experimental groups, which, in turn, presented similar resistance to fracture among each other. None of the techniques of root reconstruction with intraradicular posts improved root strength, and the incremental technique was suggested as being the most recommendable, since the type of fracture that occurred allowed the remaining dental structure to be repaired.

Conclusion

The results of this in vitro study suggest that the healthy remaining radicular dentin is more important to increase fracture resistance than the root reconstruction protocol.  相似文献   

19.

PURPOSE

Among the surface treatment methods suggested to enhance the adhesion of resin cement to fiber-reinforced composite posts, conflicting results have been obtained with silanization. In this study, the effects of silanization, heat activation after silanization, on the bond strength between fiber-reinforced composite post and resin cement were determined.

MATERIALS AND METHODS

Six groups (n=7) were established to evaluate two types of fiber post (FRC Postec Plus, D.T. Light Post) and three surface treatments (no treatment; air drying; drying at 38℃). Every specimen were bonded with dual-curing resin cement (Variolink N) and stored in distilled water for 24 hours at 37℃. Shear-bond strength (MPa) between the fiber post and the resin cement were measured using universal testing device. The data were analyzed with 1-way ANOVA and by multiple comparisons according to Tukey''s HSD (α=0.05). The effect of surface treatment, fiber post type, and the interactions between these two factors were analyzed using 2-way ANOVA and independent sample T-tests.

RESULTS

Silanization of the FRC Postec Plus significantly increased bond strength compared with the respective non-treated control, whereas no effect was determined for the D.T. Light Post. Heat drying the silane coupling agent on to the fiber-reinforced post did not significantly improve bond strength compared to air-syringe drying.

CONCLUSION

The bond strength between the fiber-reinforced post and the resin cement was significantly increased with silanization in regards to the FRC Postec Plus post. Bond strength was not significantly improved by heat activation of the silane coupling agent.  相似文献   

20.

PURPOSE

Bone density at implant placement site is a key factor to obtain the primary stability of the fixture, which, in turn, is a prognostic factor for osseointegration and long-term success of an implant supported rehabilitation. Recently, an implant motor with a bone density measurement probe has been introduced. The aim of the present study was to test the objectiveness of the bone densities registered by the implant motor regardless of the operator performing them.

MATERIALS AND METHODS

A total of 3704 bone density measurements, performed by means of the implant motor, were registered by 39 operators at different implant sites during routine activity. Bone density measurements were grouped according to their distribution across the jaws. Specifically, four different areas were distinguished: a pre-antral (between teeth from first right maxillary premolar to first left maxillary premolar) and a sub-antral (more distally) zone in the maxilla, and an interforaminal (between and including teeth from first left mandibular premolar to first right mandibular premolar) and a retroforaminal (more distally) zone in the lower one. A statistical comparison was performed to check the inter-operators variability of the collected data.

RESULTS

The device produced consistent and operator-independent bone density values at each tooth position, showing a reliable bone-density measurement.

CONCLUSION

The implant motor demonstrated to be a helpful tool to properly plan implant placement and loading irrespective of the operator using it.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏