首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
This study sought to assess the efficacy of two self-etching primer systems (Transbond Plus and Beauty Ortho Bond) on orthodontic brackets. Therefore, shear bond strengths and bracket-adhesive failure modes (ARI scores) were determined and compared against an etch-and-rinse adhesive system (Transbond XT) under two experimental conditions (dry and saliva application). Shear bond strength test was performed at a crosshead speed of 0.5 mm/min, while enamel surfaces and enamel-adhesive interfaces were examined with SEM. There were no significant differences between Transbond XT (9.15 MPa) and Transbond Plus (9.74 MPa) under the dry condition, whereas that of Beauty Ortho Bond (6.47 MPa) was significantly lower than these two systems. Under SEM examination, both self-etching primers showed a milder etching effect and decreased depth of resin penetration into intact enamel than Transbond XT. In conclusion, results of this study showed that both self-etching systems seemed to offer more merits than conventional acid etching because of fewer irreversible changes to enamel.  相似文献   

2.
The purpose of this study was to investigate the effects of enamel pre-treatment with a new fluoride-containing casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) complex on the shear bond strength (SBS) of brackets bonded with etch-and-rinse or self-etching adhesive systems. The material comprised 66 extracted human premolars randomly divided into six equal groups with respect to the enamel pre-treatment and adhesive system employed: 1. No pre-treatment and brackets bonded with the etch-and-rinse adhesive system (Transbond XT). 2. Pre-treatment with fluoride-containing CPP-ACP paste (MI Paste Plus) and Transbond XT. 3. Pre-treatment with non-fluoride CPP-ACP paste (MI Paste) and Transbond XT.4. No pre-treatment and brackets bonded with the self-etching adhesive system (Transbond Plus). 5 and 6. Enamel pre-treated as for groups 2 and 3, respectively, and the Transbond Plus. Bonded specimens were subjected to thermal cycling (×1000) before SBS testing. The residual adhesive on the enamel surface was evaluated after debonding with the adhesive remnant index (ARI). Data evaluation was made using one-way analysis of variance and Tukey test for SBS results, and Kruskal-Wallis test for ARI results. The results showed that enamel pre-treatment with either fluoride or non-fluoride CPP-ACP paste had no significant effect on the SBS of the self-etching adhesive system (P > 0.05). Enamel pre-treatment with non-fluoride CPP-ACP in group 3 significantly reduced the SBS of the etch-and-rinse adhesive (P < 0.001), while pre-treatment with fluoride-containing CPP-ACP paste (groups 2 and 5) did not affect debonding values (P > 0.05). The fluoride-containing CPP-ACP did not compromise the SBS of brackets bonded with the tested etch-and-rinse and self-etching systems, but its non-fluoride version significantly decreased the SBS of the etch-and-rinse adhesive system.  相似文献   

3.
OBJECTIVE: To compare the effects of a standardized thermocycling protocol on the shear bond strength (SBS) of two adhesive systems: a resin-modified glass ionomer and a composite resin used with a new self-etching primer. MATERIALS AND METHODS: Forty human molars were cleaned, mounted, and randomly divided into two groups. In group 1, brackets were bonded to the teeth using Fuji Ortho LC adhesive, and in group 2, the Transbond Plus system was used. The teeth were stored in water at 37 degrees C for 24 hours, thermocycled between 5 and 55 degrees C, and debonded using a universal testing machine. The enamel surface was examined under 10x magnification to determine the amount of residual adhesive remaining on the tooth. Student's t-test was used to compare the SBS and the chi-square test was used to compare the adhesive remnant index (ARI) scores. RESULTS: The mean SBS for the brackets bonded using the Fuji Ortho LC was 6.4 +/- 4.5 MPa, and the mean SBS for the Transbond Plus system was 6.1 +/- 3.2 MPa. The result of the t-test comparisons (t = 0.207) indicated that there was no significant difference (P = .837) between the two groups. The comparisons of the ARI scores (chi(2) = 0.195) indicated that bracket failure mode was not significantly different (P = .907) between the two adhesives. CONCLUSION: Although SBS and ARI scores were not significantly different for the two adhesives, clinicians need to take into consideration the other properties of the adhesives before using them.  相似文献   

4.

Objectives

This study aims to assess the shear bond strength (SBS) to enamel and the distribution of failure modes of brackets bonded using a new self-adhering flowable resin composite (Vertise Flow, VF), with or without preliminary phosphoric acid etching (PAE).

Materials and methods

Eighty extracted premolars were randomly divided into four groups (n?=?20): (1) etch-and-rinse adhesive (E&R), PAE/Transbond XT Primer/Transbond XT Paste (3M Unitek); (2) self-etch adhesive (SE), Transbond Plus Self–Etching Primer (3M Unitek)/Transbond XT Paste; (3) VF; (4) PAE/VF. In each group, 10 bracketed teeth were debonded within 30 min, while the remaining teeth were subjected to thermocycling before testing. SBS and adhesive remnant index were recorded.

Results

SE measured significantly lower early SBS than PAE/VF. Early SBSs recorded by VF were slightly higher yet statistically similar to those of E&R. Such levels of adhesion were achieved by VF regardless of preliminary PAE. After thermocycling, VF measured the lowest SBS. When debonded early, VF and SE tended to leave less residues on enamel surface than E&R. After thermocycling, the failure pattern changed significantly for VF and PAE/VF specimens that all exhibited adhesive failures at the tooth–bracket interface.

Conclusions

VF achieved early bracket SBSs similar to E&R. Following thermocycling, VF and PAE/VF manifested a significant decrease in SBS.

Clinical relevance

Although the simplified handling and the satisfactory early SBS of VF may prompt its use for bracket bonding, the decrease in retention noted after thermocycling warns that the issue of bond durability should be thoroughly addressed prior to endorsing this clinical application of VF.  相似文献   

5.
Abstract Objective: To determine if a new experimental resin-based material containing Portland cement (PC) can help prevent enamel caries while providing adequate shear bond strength (SBS). Materials and Methods: Brackets were bonded to human premolars with experimental resin-based adhesive pastes composed of three weight rations of resin and PC powder (PC 30, 7∶3; PC 50, 5∶5; PC 70, 3∶7; n = 7). Self-etching primer (SEP) adhesive (Transbond Plus) and resin-modified glass ionomer cement (RMGIC) adhesive (Fuji Ortho FC Automix) were used for comparison. All of the bonded teeth were subjected to alternating immersion in demineralizing (pH?4.55) and remineralizing (pH?6.8) solutions for 14?days. The SBS for each sample was examined, and the Adhesive Remnant Index (ARI) score was calculated. The hardness and elastic modulus of the enamel were determined by a nanoindenter at 20 equidistant depths from the external surface at 100?μm from the bracket edge. Data were compared by one-way analysis of variance and a chi-square test. Results: PC 50 and PC 70 showed significantly greater SBS than Fuji Ortho FC Automix, although Transbond Plus showed significantly greater SBS than other bonding systems. No significant difference in the ARI category was observed among the five groups. For specimens bonded with PC 50 and PC 70, the hardness and elastic modulus values in most locations were equivalent to those of Fuji Ortho FC Automix. Conclusions: Experimental resin-based bonding material containing PC provides adequate SBS and a caries-preventive effect equivalent to that of the RMGIC adhesive system.  相似文献   

6.
OBJECTIVE: To evaluate a new self-etch conditioner used with resin-modified glass ionomers (RMGIs) in bonding orthodontic brackets. MATERIALS AND METHODS: Sixty human molars were cleaned, mounted, and randomly divided into three groups. In group 1 (control), 20 orthodontic brackets were bonded to teeth using Transbond Plus Self-etching Primer; in group 2, 20 brackets were bonded using an RMGI with a 10% polyacrylic acid conditioner. In group 3, 20 brackets were bonded using Fuji Ortho LC with a new no-rinse self-conditioner for RMGIs. The same bracket type was used on all groups. The teeth were debonded in shear mode using a universal testing machine, and the amount of residual adhesive remaining on each tooth was evaluated. Analysis of variance was used to compare the shear bond strength (SBS), and the chi(2) test was used to compare the Adhesive Remnant Index (ARI) scores. RESULTS: There were no significant differences in the SBS (P = .556) between the groups. The mean SBS for Transbond Plus was 8.6 +/- 2.6 MPa, for Fuji Ortho LC using 10% polyacrylic acid 9.1 +/- 4.6 MPa, and for Fuji Ortho LC using GC Self-conditioner 9.9 +/- 4.1 MPa. The comparisons of the ARI scores between the three groups (chi(2) = 35.5) indicated that bracket failure mode was significantly different (P < .001), with more adhesive remaining on the teeth bonded using Transbond. Conclusions: The new self-etch conditioner can be used with an RMGI to successfully bond brackets. In addition, brackets bonded with Fuji Ortho LC resulted in less residual adhesive remaining on the teeth.  相似文献   

7.
The objective of this research was to investigate the effect of applying a sustained seating force during bonding on the adhesive layer and on shear bond strength (SBS) of orthodontic brackets. Forty human premolars divided into two groups were included in the study. Stainless steel brackets were bonded to the premolars with Transbond XT light cure adhesive and Transbond Plus Self Etch Primer (SEP). The brackets in both groups were subjected to an initial seating force of 300 g for 3 seconds, sufficient to position the bracket. The seating force was maintained throughout the 40 seconds of light curing in group 2. SBS was tested 24 hours after bracket bonding with a shear blade using an Instron testing unit at a crosshead speed of 2 mm/minute. A Student's t-test was used to compare the bond strength of the two groups and a chi-square test to compare the frequencies of the adhesive remnant index (ARI) scores. The mean SBS was significantly different between the two groups (P=0.025). The bond strength was higher (mean 8.15±0.89 MPa) in group 2 compared with group 1 (mean 7.39±1.14 MPa). There was no significant difference (P=0.440) in the ARI scores between the two groups. Applying a sustained seating force during orthodontic bracket bonding improves bond strength but does not change the distribution of the ARI scores.  相似文献   

8.
In orthodontic practice, it is not uncommon to bond brackets to resin composite restorations. With this in mind, this study was designed to compare first the shear/peel strengths of metal, ceramic and polycarbonate brackets bonded to microfilled resin composite (RC), using either a light-cured resin-modified glass ionomer cement (Fuji Ortho LC), a chemical-cured composite (System 1+) or a light-cured composite adhesive (Transbond XT); and then to examine the effects of thermocycling on the shear/peel strengths of these systems. Four different brackets were used: two stainless steel (Victory and Optimesh), one ceramic (Transcend 6000) and one polycarbonate (Spirit MB). Seventy-two specimens of each bracket were divided into three groups for bonding with one of the three adhesives. Half the specimens from each group were also thermocycled. Mean shear/peel bond strengths were found to be significantly different for the four different brackets, although not influenced by the three adhesives used within each group. All groups were found to have clinically-acceptable mean bond strengths, except for Spirit MB-System 1+. After thermocycling, both Optimesh-Transbond XT and Victory-System 1+ groups showed superior mean bond strengths (26.8 and 24.4 MPa, respectively) when compared with all other groups (p < 0.05). Applying the Weibull survival analysis for groups utilising Victory, Transcend 6000 and Spirit MB brackets, those with 90 per cent or greater probabilities of survival included Victory-System 1+, Transcend 6000-Fuji Ortho LC, Victory-Fuji Ortho LC and Spirit MB-Transbond XT groups. In all groups, bond failure was mainly (64 per cent) cohesive within the RC restorative surface. The thermocycled Spirit MB-Transbond XT group had the highest frequency of undamaged RC failure interfaces. Despite the focus of this study being on bond strength and the potential for surface damage, it was noted that these properties should always be considered alongside other factors such as the strength of the bracket itself, friction within the bracket slot, patients' wishes, cost of the materials and the presenting malocclusion.  相似文献   

9.
OBJECTIVE: The aim of this study was to determine the shear bond strength (SBS), etching pattern and depth, and debonding performance of several market-leading, self-etching (SE) adhesives primarily used in restorative dentistry (iBond, Clearfil S(3) Bond, Clearfil Protect Bond, AdheSE, XenoIII), two experimental self-etching adhesives (exp. Bond 1, exp. Bond 2) and one experimental self-etching cement (SE Zement) used with and without prior phosphoric acid-etching, and to compare them to an orthodontic self-etching product (Transbond Plus SE Primer) and to traditional acid-etch technique (Transbond XT Primer, phosphoric acid) MATERIALS AND METHODS: All adhesives were applied on pumiced and embedded bovine incisors following the manufacturers' instructions. Then one bracket each (coated with Transbond XT composite) was bonded (n = 20). Transbond XT was polymerized for 20 s from the incisal and gingival sides using a halogen device positioned at a constant 5 mm from and a 45 degrees angle to the specimen. The specimens were stored in distilled water for 24 h at 37 degrees C before measuring SBS. The ARI (adhesive remnant index) for all specimens was determined from the sheared-off brackets of each. After conditioning, the surface texture was morphologically evaluated from scanning electron microscope (SEM) images, while the etching depth was determined using a confocal laser-scanning microscope (CLSM). All groups were tested for normal distribution and analyzed by applying ANOVA, Kruskal-Wallis or the t test. In addition, a Bonferroni correction was used. RESULTS: The median values of the SBS tests were: SE Zement 3.0 MPa, SE Zement preceded by phosphoric acid etching 11.2 MPa, experimental bond 1: 7.4 MPa, experimental bond 2: 5.6 MPa, iBond 8.1 MPa, Clearfil S(3) Bond 14.1 MPa, Clearfil Protect Bond 16.6 MPa, Clearfil SE Bond 15.9 MPa, AdheSE 16.0 MPa, XenoIII 16.1 MPa, Transbond SE Primer 20.7 MPa, acid-etching+Transbond XT Primer 21.0 MPa. With the exception of iBond, we observed no significant differences among the self-etching adhesives used in Restorative Dentistry or in comparison to the Transbond Plus SE Primer. No significant differences were apparent even when compared to the Transbond XT Primer after phosphoric acid-etching. Both experimental bonding agents and SE Zement without acid etching performed significantly worse than the products mentioned above, failing to demonstrate sufficient adhesive strength. SEM examination revealed less distinctive enamel-etching patterns for self-etching products than for phosphoric acid-etching. CLSM analysis revealed etching depths between 0.5 and 20 microm depending on the product. When self-etching products were used, less residual composite remained on the enamel surface than after phosphoric acid-etching. CONCLUSIONS: All the adhesives tested are suitable for bonding orthodontic brackets and to reduce the risk of enamel fracture while minimizing etching depth, which in turns means less conditioning-related enamel loss. More development is needed to improve the etching performance of both experimental bonding agents and SE Zement.  相似文献   

10.
Three types of experimental resin cements with different curing systems, dual, light, and chemical, were designed. The relationship between the flexural strengths of the three experimental and five commercial (Beauty Ortho Bond, Transbond? XT, Light Cure Bond, Kurasper? F, and Super Bond) orthodontic resin cements on the tensile bond strength (TBS) and shear bond strength (SBS) of metal brackets to enamel was determined. Seven specimen bars of each resin were prepared for measuring the flexural strengths of the resins. Bonded specimens of each resin were prepared, seven for measuring TBS and seven SBS for after bonding of a metal bracket to a maxillary central human labial anterior tooth using experimental and commercial resin cements. The results were analysed by one-way analysis of variance and Scheffé's multiple comparison tests. The level of statistical significance was set at 0.05. Increases in the flexural strength of the resin cements were related to increases in the TBS and SBS of the metal bracket. While the light-curing cements exhibited a strong linear correlation between flexural strengths and TBS or SBS, the dual- and chemical-curing cements exhibited a different flexural strength effect on both TBS and SBS. This was a result of the adhesive layer under the metal bracket, which could be chemically cured, in contrast to the light-curing cement. To control setting time and to obtain higher initial TBS and SBS by polymerizing the resin cement under the bracket, a dual-curing system, that combines both light- and chemical-curing systems, is essential.  相似文献   

11.
The shear bond strength (SBS) of a light-cured, resin-reinforced glass ionomer and a composite adhesive in combination with a self-etching primer was compared after different setting times to evaluate when orthodontic wires could be placed. Additionally, the fracture site after debonding was assessed using the Adhesive Remnant Index (ARI). Eighty freshly extracted human premolars were used. Twenty teeth were randomly assigned to each of four groups: (1) brackets bonded with Transbond XT with a Transbond Plus etching primer and debonded within 5 minutes; (2) brackets bonded with Fuji Ortho LC and debonded within 5 minutes; (3) brackets bonded as for group 1 and debonded within 15 minutes; (4) brackets bonded as for group 2 and debonded within 15 minutes. The SBS of each sample was determined with an Instron machine. The mean SBS were, respectively: (1) 8.8 +/- 2 MPa; (2) 6.6 +/- 2.5 MPa; (3) 11 +/- 1.6 MPa and (4) 9.6 +/- 1.6 MPa. Interpolating the cumulative fracture probability by means of a Weibull analysis, the 10 per cent probabilities of fracture for the groups were found to be attained for shear stresses of 6.1, 3.1, 8.3 and 7.1 MPa, respectively. Chi-square testing of the ARI scores revealed that the nature of the remnant did not vary significantly with time, but the type of bonding material could generally be distinguished in leaving more or less than 10 per cent of bonding material on the tooth. After debonding, the Transbond system was likely to leave adhesive on at least 10 per cent of the bonded area of the tooth. The present findings indicate that brackets bonded with either Transbond XT in combination with Transbond Plus etching primer and Fuji Ortho LC had adequate bond strength at 5 minutes and were even stronger 15 minutes after initial bonding.  相似文献   

12.
Abstract

Aim. This study aimed to evaluate the effect of pre-heated composite restoratives on the shear bond strength (SBS) of orthodontic brackets. Methods. The following materials were tested: a microhybrid composite restorative (Filtek Z250), two nanofilled composite restoratives (Filtek Z350 and NT Premium), a nanohybrid composite restorative (Brilliant) and a conventional orthodontic adhesive (Transbond XT). All materials were stored for 1 h in the incubator either at 25°C (room temperature simulation) or 60°C before bonding 100 orthodontic brackets on bovine lower incisors (n = 10). One Coat Bond SL and Transbond XT were used to bond the composite restoratives and the Transbond XT adhesive paste, respectively. After storage in distilled water for 24 h, the brackets were subjected to SBS test at a speed of 0.5 mm/min until bracket debonding. The Adhesive Remnant Index (ARI) was assigned to the fractured specimens. Data were analyzed using the one-way ANOVA and the Tukey post-hoc test (p < 0.05). The Kruskal-Wallis test was used to compare ARI scores between the groups (p < 0.05). Results. There was no statistically significant difference between the materials at room temperature. Samples bonded with pre-heated materials showed a statistically higher SBS than those bonded with room temperature materials. Samples bonded with the pre-heated orthodontic adhesive showed the highest SBS among all the pre-heated materials. All preheated composite restoratives produced an SBS mean higher than that of Transbond XT stored at room temperature. Conclusion. The use of pre-heated composite restoratives and orthodontic adhesives might be an alternative approach to bond orthodontic brackets.  相似文献   

13.
In orthodontics, adhesive failures can occur because of saliva contamination during bonding. However, most in vitro studies concerning bond strength of saliva-contaminated enamel disregard the influence of temperature changes in a wet environment. The aim of the present study was to compare the influence of saliva, blood and etching gel remnant contamination on shear bond strength (SBS) after thermocycling. After etching of extracted human third molars (n = 80), a conventional primer (Transbond XT) and a moisture-insensitive primer (Transbond MIP) were evaluated using the adhesive, Transbond XT, under dry conditions and after contamination with saliva, blood and etching gel remnants. To simulate temperature changes and the moisture of saliva in the oral cavity, all samples were thermocycled (6,000 x 5 degrees C/55 degrees C) in a mastication device before SBS testing. A Mann-Whitney U test was used to determine statistical differences. Under dry conditions Transbond XT and Transbond MIP showed no significant difference in SBS. However, clinically unacceptable (P = 0.005) bond strength was observed using Transbond XT after saliva and blood contamination. In wet conditions only Transbond MIP showed sufficient bond strength. If contamination during bonding is expected, a hydrophilic primer should be used. Under dry conditions hydrophilic or hydrophobic primers could be applied. Blood contamination seems to be a more serious problem for bond strength than saliva or etching gel contamination.  相似文献   

14.
OBJECTIVE: To compare the shear bond strength (SBS) of orthodontic brackets when the self-etching primer (SEP) and the bracket adhesive are light cured either separately or simultaneously. MATERIALS AND METHODS: Seventy-five human molars were randomly divided into five equal groups. Brackets precoated with Transbond XT composite adhesive were used. The five protocols were: Group 1 (control), the SEP Transbond Plus was applied, brackets placed, and adhesive light cured for 20 seconds; Group 2, SEP Adper Prompt L-Pop was applied, light cured, brackets placed, and light cured; Group 3, the same SEP as in Group 2 was used, however, the SEP and bracket adhesive were light cured together; Group 4, SEP Clearfil S3 Bond was applied, light cured, brackets placed, and light cured; and Group 5, the same SEP as in group 4 was used, however, the SEP and the adhesive were light cured together. The teeth were debonded using a universal testing machine, and the enamel was examined for residual adhesive. Analysis of variance was used to compare the SBS. RESULTS: The SBS of Clearfil S3 Bond after one light cure and two light cures were significantly greater than the bonds of brackets using Transbond Plus. Brackets bonded using Adper Prompt L-Pop after one light cure and two light cures were not significantly different from the other groups. The groups did not differ significantly in their bracket failure modes. CONCLUSION: Only one light curing application is needed to successfully bond brackets when using SEPs and adhesives. This approach can potentially reduce technique sensitivity as well as chair time.  相似文献   

15.
The aim of this study was to determine the shear bond strength of different composites and to determine the adhesive remnant index (ARI) of metallic brackets bonded to enamel prepared with Transbond Plus Self-Etching Primer (TPSEP). Forty human premolars were divided into four equal groups. In group 1 (control), the Transbond XT was conventionally used. In groups 2-4, the TPSEP was used before bonding with Transbond XT, Z-100, and Concise Orthodontic, respectively. After the bonding, the samples were stored in distilled water at 37 degrees C for 24 hours. The brackets were debonded using a universal testing machine at a crosshead speed of 0.5 mm/ min. The shear bond strength (MPa) for group 1 (control), group 2 (TPSEP + Transbond XT), group 3 (TPSEP + Z-100), and group 4 (TPSEP + Concise Orthodontic) were of 6.43, 4.61, 4.74, and 0.02, respectively. Group 1 was statistically superior to other groups (P < .05), but there was no statistically significant difference between groups 2 and 3 (P > .05), although both were statistically superior to group 4 (P < .05). According to the ARI evaluation, most of the failures involved the bracket/composite interface (groups 1 and 2) as well as the enamel/composite interface (groups 3 and 4). The Transbond XT conventionally bonded showed better adhesion results than Transbond XT, Z-100, and Concise Orthodontic after using Transbond Plus Self-Etching Primer.  相似文献   

16.
OBJECTIVE: To evaluate the effect of a self-etching primer on shear bond strengths (SBS) at the different debond times of 5, 15, 30, and 60 minutes and 24 hours. MATERIALS AND METHODS: Brackets were bonded to human premolars with different etching protocols. In the control group (conventional method [CM]) teeth were etched with 37% phosphoric acid. In the study group, a self-etching primer (SEP; Transbond Plus Self Etching Primer; 3M Unitek, Monrovia, Calif) was applied as recommended by the manufacturer. Brackets were bonded with light-cure adhesive paste (Transbond XT; 3M Unitek) and light-cured for 20 seconds in both groups. The shear bond test was performed at the different debond times of 5, 15, 30 and 60 minutes and 24 hours. RESULTS: Lowest SBS was attained with a debond time of 5 minutes for the CM group (9.51 MPa) and the SEP group (8.97 MPa). Highest SBS was obtained with a debond time of 24 hours for the CM group (16.82 MPa) and the SEP group (19.11 MPa). Statistically significant differences between the two groups were not observed for debond times of 5, 15, 30, or 60 minutes. However, the SBS values obtained at 24 hours were significantly different (P < .001). CONCLUSIONS: Adequate SBS was obtained with self-etching primer during the first 60 minutes (5, 15, 30 and 60 minutes) when compared with the conventional method. It is reliable to load the bracket 5 minutes after bonding using self-etching primer (Transbond Plus) with the light-cure adhesive (Transbond XT).  相似文献   

17.
OBJECTIVE: The purpose of this study was to determine whether a self-adhesive universal cement, RelyX Unicem (3M ESPE, Seefeld, Germany), can be used successfully to bond orthodontic brackets to enamel. MATERIALS AND METHODS: Forty human molars were cleaned, mounted, and randomly divided into two groups: 20 orthodontic brackets were bonded to teeth using RelyX Unicem, and 20 brackets were bonded using the Transbond XT (3M Unitex, Monrovia, Calif) adhesive system. The teeth were debonded within 30 minutes after initial bonding using a universal testing machine. After debonding, the enamel surface was examined under 10x magnification to determine the amount of residual adhesive remaining on the tooth. Student's t-test was used to compare the shear bond strength (SBS) of the two groups, and the chi-square test was used to compare the Adhesive Remnant Index (ARI) scores for the two adhesive systems. RESULTS: The mean SBS of the brackets bonded using the RelyX Unicem was 3.7 +/- 2.1 MPa and was significantly lower (t = 2.07, P = .048) than the SBS of the brackets bonded with the Transbond system (x = 5.97 +/- 4.2 MPa). The comparisons of the ARI scores between the two groups (chi(2) = 17.4) indicated that bracket failure mode was significantly different (P = .002) with more adhesive remaining on the teeth bonded with Transbond XT. CONCLUSIONS: The SBS of the self-adhesive universal cement needs to be increased for it to be successfully used for bonding orthodontic brackets.  相似文献   

18.
High bond strengths are required in order to avoid bracket failure during treatment while brackets should be removable. In addition, chair time should be kept at a minimum. Therefore, the aim of this study was to investigate any differences in bracket's bond strength to enamel by reducing the polymerization time and the steps of bonding procedure. Five hundred teeth were randomly allocated into 20 groups. The groups were established considering the investigated curing units (quartz–tungsten–halogen (QTH) and light-emitting diode (LED), each with two different polymerization times) and the used bonding agents (Clearfil SE Bond, Transbond Plus, Ideal1, iBond, and Transbond XT Primer following acid etching). The brackets were debonded using a shear-peel load and used to calculate the bond strength. The location of adhesive failure was registered by using the modified adhesive remnant index (ARI). The influence of the parameters curing unit, curing time, and bonding agent as well as their interaction products on bond strength showed that the bonding agent influenced the bond strength most followed by curing time. The parameter curing unit as well as all the generated interaction products of it showed a lower impact. Regarding the ARI, the bonding agent exhibited also the highest influence. Using a LED resulted in comparable bond strengths as the QTH curing device also at shorter exposure times. Additionally, the two-component self-etching primers showed similar bond strengths compared to the acid-etching method. Chair time can be reduced by using two-component self-etching primers and LED without decrease of bond strength.  相似文献   

19.
OBJECTIVE: To determine whether the combination of a new antimicrobial primer and a fluoride-releasing adhesive will affect the shear bond strength (SBS) and the bracket/adhesive failure mode. MATERIALS AND METHODS: A total of 120 extracted human teeth were randomly divided into three groups of 40 specimens each (20 incisors, 20 premolars). Transbond XT was used in group 1, a fluoride-releasing adhesive (Kurasper F) was used in group 2, and a new antimicrobial self-etching primer (Clearfil Protect Bond) was applied in combination with Kurasper F in group 3. A universal testing machine was used to determine the SBS, and the adhesive remaining after debonding was assessed. RESULTS: No enamel fractures were detected in any of the specimens. SBS values for incisors and premolars were 11.40 +/- 4.65 MPa and 10.37 +/- 3.36 MPa in group 1, 14.50 +/- 4.22 MPa and 13.06 +/- 5.13 MPa in group 2, and 14.79 +/- 4.10 MPa and 14.60 +/- 3.55 MPa in group 3. Statistically significant difference (P = .001) was found in the premolars in group 3 revealing the highest mean SBS. Significantly lower adhesive remnant index (ARI) values (median ARI value of 1) were detected in group 3 when compared with groups 1 and 2. CONCLUSIONS: Considering the acceptable bond strength and the mode of failure, the combination of the new antimicrobial primer with the fluoride-releasing adhesive is recommended for clinical use.  相似文献   

20.

Aim

The objective of present study was to examine influence of adhesives and methods of enamel pretreatment on the shear bond strength (SBS) of orthodontic brackets. The adhesives used were resin-reinforced glass ionomer cements-GIC (Fuji Ortho LC) and composite resin (Transbond XT).

Material and Methods

The experimental sample consisted of 80 extracted human first premolars. The sample was divided into four equal groups, and the metal brackets were bonded with different enamel pretreatments by using two adhesives: group A-10% polyacrylic acid; Fuji Ortho LC, group B–37% phosphoric acid; Fuji Ortho LC, group C–self etching primer; Transbond XT, group D–37% phosphoric acid, primer; Transbond XT. SBS of brackets was measured. After debonding of brackets, the adhesive remnant index (ARI) was evaluated.

Results

After the statistical analysis of the collected data was performed (ANOVA; Sheffe post-hoc test), the results showed that significantly lower SBS of the group B was found in relation to the groups C (p=0.031) and D (p=0.026). The results of ARI were similar in all testing groups and it was not possible to determine any statistically significant difference of the ARI (Chi- square test) between all four experimental groups.

Conclusion

The conclusion is that the use of composite resins material with appropriate enamel pretreatment according to manufacturer’s recommendation is the “gold standard” for brackets bonding for fixed orthodontic appliances.Key words: orthodontic brackets, shear strength, adhesive, enamel preparation  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号