首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 281 毫秒
1.
The difficult balance between thrombosis and bleeding after transcatheter aortic valve replacement. TAVR: transcatheter aortic valve replacement.
  相似文献   

2.
Central illustration. Patient-centred benefit versus risk analysis of early aortic valve replacement (AVR) for asymptomatic severe aortic stenosis. AKI: acute kidney injury; PM: pacemaker; PPM: patient prosthesis mismatch.
  相似文献   

3.
Central Illustration. Pathophysiological pathways providing a causal link between high plasma concentrations of lipoprotein(a) (Lp(a)) and atherosclerotic vascular disease and aortic valve stenosis (AVS). Clinical outcomes are related to accelerated atherosclerosis complicated by atherothrombosis (myocardial infarction, stroke), peripheral artery disease (PAD) or aortic valve replacement (AVR) caused by valve calcification and aortic stenosis. Apo(a): apolipoprotein(a); LDL: low-density lipoprotein; OxPL: oxidized phospholipids; NSFA: Nouvelle Société Francophone d’Athérosclérose; SP: serine-protease domain; V: plasminogen kringle V (reproduced with permission).
  相似文献   

4.
BackgroundBioprosthetic valve thrombosis may have implications for valve function and durability.ObjectivesUsing a novel glycoprotein IIb/IIIa receptor radiotracer 18F-GP1, we investigated whether positron emission tomography (PET)-computed tomography (CT) could detect thrombus formation on bioprosthetic aortic valves.MethodsEx vivo experiments were performed on human platelets and explanted bioprosthetic aortic valves. In a prospective cross-sectional study, patients with either bioprosthetic or normal native aortic valves underwent echocardiography, CT angiography, and 18F-GP1 PET-CT.ResultsFlow cytometric analysis, histology, immunohistochemistry, and autoradiography demonstrated selective binding of 18F-GP1 to activated platelet glycoprotein IIb/IIIa receptors and thrombus adherent to prosthetic valves. In total, 75 participants were recruited: 53 with bioprosthetic valves (median time from implantation 37 months [IQR: 12-80 months]) and 22 with normal native aortic valves. Three participants had obstructive valve thrombosis, and a further 3 participants had asymptomatic hypoattenuated leaflet thickening on CT angiography. All bioprosthetic valves, but none of the native aortic valves, demonstrated focal 18F-GP1 uptake on the valve leaflets: median maximum target-to-background ratio 2.81 (IQR: 2.29-3.48) vs 1.43 (IQR: 1.28-1.53) (P < 0.001). Higher 18F-GP1 uptake was independently associated with duration of valve implantation and hypoattenuated leaflet thickening. All 3 participants with obstructive valve thrombosis were anticoagulated for 3 months, leading to resolution of their symptoms, improvement in mean valve gradients, and a reduction in 18F-GP1 uptake.ConclusionsAdherence of activated platelets is a common and sustained finding on bioprosthetic aortic valves. 18F-GP1 uptake is higher in the presence of thrombus, regresses with anticoagulation, and has potential use as an adjunctive clinical tool. (18F-GP1 PET-CT to Detect Bioprosthetic Aortic Valve Thrombosis; NCT04073875)  相似文献   

5.
ObjectivesThe aim of this study was to assess the added value and predictive power of the TAVIguide (Added Value of Patient-Specific Computer Simulation in Transcatheter Aortic Valve Implantation) software in clinical practice.BackgroundOptimal outcome after transcatheter aortic valve replacement (TAVR) may become more important as TAVR shifts toward low-risk patients. Patient-specific computer simulation is able to provide prediction of outcome after TAVR. Its clinical role and validation of accuracy, however, have not yet been studied prospectively.MethodsA prospective, observational, multicenter study was conducted among 80 patients with severe aortic stenosis treated with the Evolut R valve. Simulation was performed in 42 patients and no simulation in 38. A comparison between the valve size (decision 1) and target depth of implantation selected by the operator on the basis of multislice computed tomography and the valve size (decision 2) and target depth of implantation selected after simulation were the primary endpoints. Predictive power was examined by comparing the simulated and observed degree of aortic regurgitation.ResultsDecision 2 differed from decision 1 in 1 of 42 patients because of predicted paravalvular leakage, and changes in valve type occurred in 2 of 42. In 39 of 42 patients, decisions 1 and 2 were similar. Target depth of implantation differed in 7 of 42 patients after simulation (lower in 4 and higher in 3). In 16 of 42 patients, simulation affected the TAVR procedure; in 9, the operator avoided additional measures to achieve the target depth of implantation, and in 7 patients, additional measures were performed. There was a trend toward a higher degree of predicted than observed aortic regurgitation (17.5 vs. 12 ml/s; p = 0.13).ConclusionsPatient-specific computer simulation did not affect valve size selection but did affect the selection of the target depth of implantation and the execution of TAVR to achieve the desired target depth of implantation.  相似文献   

6.
BackgroundAortic valve stenosis is a progressive disorder with variable progression rates. The factors affecting aortic stenosis (AS) progression remain largely unknown.ObjectivesThis systematic review and meta-analysis sought to determine AS progression rates and to assess the impact of baseline AS severity and sex on disease progression.MethodsThe authors searched Medline, Embase, and the Cochrane Central Register of Controlled Trials from inception to July 1, 2020, for prospective studies evaluating the progression of AS with the use of echocardiography (mean gradient [MG], peak velocity [PV], peak gradient [PG], or aortic valve area [AVA]) or computed tomography (calcium score [AVC]). Random-effects meta-analysis was performed to evaluate the rate of AS progression for each parameter stratified by baseline severity, and meta-regression was performed to determine the impact of baseline severity and of sex on AS progression rate.ResultsA total of 24 studies including 5,450 patients (40% female) met inclusion criteria. The pooled annualized progression of MG was +4.10 mm Hg (95% CI: 2.80-5.41 mm Hg), AVA −0.08 cm2 (95% CI: 0.06-0.10 cm2), PV +0.19 m/s (95% CI: 0.13-0.24 m/s), PG +7.86 mm Hg (95% CI: 4.98-10.75 mm Hg), and AVC +158.5 AU (95% CI: 55.0-261.9 AU). Increasing baseline severity of AS was predictive of higher rates of progression for MG (P < 0.001), PV (P = 0.001), and AVC (P < 0.001), but not AVA (P = 0.34) or PG (P = 0.21). Only 4 studies reported AS progression stratified by sex, with only PV and AVC having 3 studies to perform a meta-analysis. No difference between sex was observed for PV (P = 0.397) or AVC (P = 0.572), but the level of confidence was low.ConclusionsThis study provides progression rates for both hemodynamic and anatomic parameters of AS and shows that increasing hemodynamic and anatomic baseline severity is associated with faster AS progression. More studies are needed to determine if sex differences affect AS progression. (Aortic Valve Stenosis Progression Rate: A Systematic Review and Meta-Analysis; CRD42021207726)  相似文献   

7.
Introduction and objectivesWe aimed to describe the feasibility and preliminary outcomes of commissural alignment (CA) for the balloon-expandable transcatheter heart valve.MethodsThe relationship among native commissures and transcatheter aortic valve implantation neocommissures was analyzed in 10 consecutive patients with tricuspid severe aortic stenosis undergoing transcatheter aortic valve implantation after guided implantation based on computed tomography analysis with a self-developed software. CA was predicted by in silico bio-modelling in the 10 patients and the calculated rotation was applied during crimping. Degrees of CA and coronary overlap (CO) were measured through 1-month follow up computed tomography. Transvalvular residual gradients and the rate of paravalvular leak were also analyzed.ResultsMean commissural misalignment was 16.7 ± 8°. Four patients showed mild misalignment but none of them showed a moderate or severe degree of misalignment. The in silico model accurately predicted the final in vivo position with a correlation coefficient of 0.983 (95%CI, 0.966-0.992), P < .001. Severe CO with right coronary ostium occurred in 3 patients likely due to ostial eccentricity, and CO was not present with the left coronary artery in any of the patients. Mean transaortic gradient was 6.1 ± 3.3 mmHg and there were no moderate-severe paravalvular leaks.ConclusionsPatient-specific rotation during valve crimping based on preprocedural computed tomography is feasible with balloon-expandable devices and is associated with the absence of moderate or severe commissural misalignment and left main CO.Full English text available from:www.revespcardiol.org/en  相似文献   

8.
BackgroundTranscatheter aortic valve implantation now has a major role in the treatment of patients with severe aortic stenosis. However, evidence is scarce on its feasibility and safety to treat patients with pure aortic regurgitation.AimsWe sought to evaluate the results of transcatheter aortic valve implantation using the balloon-expandable SAPIEN 3 transcatheter heart valve (Edwards Lifesciences, Irvine, CA, USA) in patients with pure aortic regurgitation on native non-calcified valves.MethodsWe conducted a retrospective and prospective French multicentre observational study. We included all patients with symptomatic severe pure aortic regurgitation on native non-calcified valves, contraindicated to or at high risk for surgical valve replacement, who underwent transcatheter aortic valve implantation using the SAPIEN 3 transcatheter heart valve.ResultsA total of 37 patients (male sex, 73%) with a median age of 81 years (interquartile range 69–85 years) were screened using transthoracic echocardiography and computed tomography and were included at eight French centres. At baseline, 83.8% of patients (n = 31) had dyspnoea New York Heart Association class  III. The device success rate was 94.6% (n = 35). At 30 days, the all-cause mortality rate was 8.1% (n = 3) and valve migration occurred in 10.8% of cases (n = 4). Dyspnoea New York Heart Association class  II was seen in 86.5% of patients (n = 32), and all survivors had aortic regurgitation grade  1. At 1-year follow-up, all-cause mortality was 16.2% (n = 6), 89.7% (n = 26/29) of survivors were in New York Heart Association class  II and all had aortic regurgitation grade  2.ConclusionTranscatheter aortic valve implantation using the SAPIEN 3 transcatheter heart valve seems promising to treat selected high-risk patients with pure aortic regurgitation on non-calcified native valves, contraindicated to surgical aortic valve replacement.  相似文献   

9.
Central illustration. Summary of strategies to improve atrial fibrillation (AF) ablation outcomes in obese patients. BMI: body mass index; BS: bariatric surgery; CT: computed tomography; CV: cardiovascular; EAM: electro-anatomical mapping system; EAT: epicardial adipose tissue; MRI: magnetic resonance imaging; NOAC: non-vitamin K antagonist oral anticoagulant; PAF: paroxysmal atrial fibrillation; TOE: transoesophageal echocardiography; TTE: transthoracic echocardiography; US: ultrasound; VKA: vitamin K antagonist.
  相似文献   

10.
ObjectivesThe aim of this study was to define predictors of prosthesis-patient mismatch (PPM) and its impact on mortality after transcatheter aortic valve replacement (TAVR) with self-expandable valves (SEVs) in patients with small annuli.BackgroundTAVR seems to reduce the risk for PPM compared with surgical aortic valve replacement, especially in patients with small aortic annuli. Nevertheless, predictors and impact of PPM in this population have not been clarified yet.MethodsPredictors of PPM and all-cause mortality were investigated using multivariable logistic regression analysis from the cohort of the TAVI-SMALL (International Multicenter Registry to Evaluate the Performance of Self-Expandable Valves in Small Aortic Annuli) registry, which included patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area <400 mm2 on computed tomography) treated with transcatheter SEVs: 445 patients with (n = 129) and without (n = 316) PPM were enrolled.ResultsIntra-annular valves conferred increased risk for PPM (odds ratio [OR]: 2.36; 95% confidence interval [CI]: 1.16 to 4.81), while post-dilation (OR: 0.46; 95% CI: 0.25–0.84) and valve oversizing (OR: 0.53; 95% CI: 0.28–1.00) seemed to protect against PPM occurrence. At a median follow-up of 354 days, patients with severe PPM, but not those with moderate PPM, had a higher all-cause mortality rate compared with those without PPM (log-rank p = 0.008). Multivariable Cox regression confirmed severe PPM as an independent predictor of all-cause mortality (hazard ratio: 4.27; 95% CI: 1.34 to 13.6).ConclusionsAmong patients with aortic stenosis and small aortic annuli undergoing transcatheter SEV implantation, use of intra-annular valves yielded higher risk for PPM; conversely, post-dilation and valve oversizing protected against PPM occurrence. Severe PPM was independently associated with all-cause mortality.  相似文献   

11.
Central illustration. Six-month mortality according to category of coronary artery calcium (CAC). The mortality rate increased with the magnitude of calcifications according to a visual scoring of CAC on chest computed tomography. CAC was associated with 6-month mortality, independent of conventional cardiovascular risk-factors, in patients hospitalized for coronavirus disease 2019 without known atheromatous disease. CI: confidence interval; HR: hazard ratio.
  相似文献   

12.
Introduction and objectivesFinal position of the neo-commissures is uncontrolled during transcatheter aortic valve implantation (TAVI), potentially hindering coronary access and future procedures. We aimed to develop a standard method to achieve commissural alignment with the ACURATE neo valve.MethodsThe relationship between native and TAVI neo-commissures was analyzed in 11 severe aortic stenosis patients undergoing TAVI. Based on computed tomography analysis, an in silico model was developed to predict final TAVI commissural posts position. A modified implantation technique, accurate commissural alignment (ACA) and a dedicated delivery system were developed. TAVI implants were tested in 3-dimensional (3D) printed models and in vivo. Commissural misalignment and coronary overlap (CO) were analyzed.ResultsThe in silico model accurately predicted final position of commissural posts irrespective of the implantation technique performed (correlation coefficient, 0.994; 95%CI, 0.989-0.998; P < .001). TAVI implant with patient-specific rotation was simulated in 3D printed models and in 9 patients. ACA-oriented TAVI implants presented adequate commissural alignment in vivo (mean commissural misalignment of 7.7 ± 3.9°). None of the ACA oriented implants showed CO, whereas in silico conventional implants predicted CO in 6 of the 9 cases.ConclusionsAccurate commissural alignment of the ACURATE neo device is feasible by inserting the delivery system with a patient-specific rotation based on computed tomography analysis. This is a simple and reproducible method for commissural alignment that can be potentially used for all kinds of TAVI devices.  相似文献   

13.
BackgroundIn transcatheter aortic valve implantation, high implantation on the aortic annulus may prevent conduction pathway injury, leading to a decrease in the rate of permanent pacemaker implantation.AimTo assess the impact of high implantation of SAPIEN 3 on the prevention of permanent pacemaker implantation.MethodsSince August 2020, we have performed high implantation by fluoroscopically positioning the lower part of the lucent line at the virtual basal ring line on a coplanar view before valve implantation. Patients treated before the adoption of this method were defined as the conventional group. We compared the high implantation group with the conventional group using propensity score analysis.ResultsOverall, the high implantation group (n = 95) showed a significantly shorter ventricular strut length than the conventional group (n = 85): median 1.3 (interquartile range 0.2–2.4) mm vs 2.8 (1.8–4.1) mm (P < 0.001). The permanent pacemaker implantation rate was significantly lower in the high implantation group than in the conventional group (2.1% vs 11.8%; P = 0.009). According to 100 propensity score analyses based on multiple imputation and the selection of appropriate covariates, the median P value for the comparison of permanent pacemaker implantation rates after transcatheter aortic valve implantation between the high implantation group and the conventional group ranged between 0.001 and 0.017, indicating a more significant reduction in the permanent pacemaker implantation rate in the high implantation group than in the conventional group. Neither valve dislodgement nor the need for a second valve was observed in either group.ConclusionsThe high implantation of SAPIEN 3 successfully decreases ventricular strut length, reducing the permanent pacemaker implantation rate after transcatheter aortic valve implantation.  相似文献   

14.
ObjectivesThis study sought to evaluate the 30-day and 1-year safety and performance of the Hydra transcatheter aortic valve (THV) in the treatment of symptomatic severe aortic stenosis in patients at high or extreme surgical risk.BackgroundThe Hydra THV is a novel repositionable self-expanding system with supra-annular bovine pericardial leaflets.MethodsThe Hydra CE study was a premarket, prospective, multicenter, single-arm study conducted across 18 study centers in Europe and Asia-Pacific countries. The primary endpoint was all-cause mortality at 30 days. All endpoints were adjudicated by an independent clinical events committee.ResultsA total of 157 patients (79.2 ± 7.1 years of age, 58.6% female; Society of Thoracic Surgeons score 4.7 ± 3.4%) were enrolled. Successful implantation was achieved in 94.3% cases. At 30 days, there were 11 (7.0%) deaths, including 9 (5.7%) cardiovascular deaths, of which 5 (3.2%) were device related. At 1 year, there were 23 (14.6%) deaths, including 13 (8.3%) cardiovascular deaths. At 30 days, there were significant improvement of effective orifice area (from 0.7 ± 0.2 cm2 to 1.9 ± 0.6 cm2) and mean aortic valve gradient (from 49.5 ± 18.5 mm Hg to 8.1 ± 3.7 mm Hg), which were sustained up to 1 year. Moderate or severe paravalvular leak was observed in 6.3% of patients at 30 days and 6.9% of patients at 1 year. The rate of new permanent pacemaker implantation was 11.7% at 30 days and 12.4% at 1 year.ConclusionsThe Hydra CE study demonstrated that transcatheter aortic valve replacement with Hydra THV offered favorable efficacy at 1 year, providing large effective orifice area and low transvalvular gradient as well as acceptable complication rates with regard to new permanent pacemaker and paravalvular leak. (A Clinical Evaluation of the HYDRA Self Expanding Transcatheter Aortic Valve; NCT02434263)  相似文献   

15.
BackgroundResults and durability of aortic valve replacement in aortic stenosis are well known, but no study has focused on the results of aortic valve replacement in aortic insufficiency.AimThe aim of this retrospective study was to describe our mid-term outcomes after aortic valve replacement for aortic insufficiency.MethodsAll consecutive adult patients who underwent bioprosthetic aortic valve replacement for aortic insufficiency at two European centres (in France and Germany) between May 2005 and December 2020 were analysed.ResultsDuring the study period, 289 patients were included. Mean age was 56.9 ± 12.5 years. Overall operative mortality was 1.5%, and the 10-year survival estimate rate was 75.0%, which was significantly lower than in the age- and sex-matched general population, with a standardized mortality ratio of 2.88 (95% confidence interval 1.96–4.08; P < 0001). Freedom from aortic valve-related death was 87.6%, and from aortic valve-related reoperation was 87.4%. No patient aged > 60 years was reoperated on during follow-up. Freedom from severe structural valve deterioration at 10 years was 73.3%, and freedom from moderate structural valve deterioration at 10 years was 50.3%. Freedom from major adverse valve-related events at 10 years was 69.7%.ConclusionsAlthough bioprosthetic aortic valve replacement for aortic insufficiency shows good early results, 10-year mortality and major adverse valve-related event rates in young patients may be a concern, with a reduction in life expectancy compared with the general population.  相似文献   

16.
BackgroundEarly hypoattenuated leaflet thickening (HALT) occurs in at least 10% of all transcatheter aortic valve replacement (TAVR) patients. The long-term prognostic impact of HALT is uncertain.ObjectivesThe aim of this study was to assess the long-term risk of early HALT post-TAVR.MethodsWe report outcome data from our prospective observational registry with post-TAVR computed tomography angiography performed between May 2012 and December 2017. The outcomes were survival, cardiovascular mortality, ischemic cerebrovascular events, and symptomatic hemodynamic valve deterioration.ResultsEarly HALT was diagnosed in 115 (16.0%) of 804 patients. During a median follow-up of 3.25 years, survival rates did not differ significantly between patients with and without HALT (Kaplan-Meier 3-year estimates for survival 70.1% vs 74.0%, P = 0.597). The 3-year cardiovascular mortality rate was 13.2% versus 11.3% (with vs without HALT, P = 0.733). The 3-year event rate for cerebrovascular events was 2.0% versus 4.4% (with vs without HALT, P = 0.246), and the 3-year event rate of symptomatic hemodynamic valve deterioration was 9.4% versus 1.5% (with vs without HALT, P < 0.001). Multivariable analysis revealed the following predictors of symptomatic hemodynamic valve deterioration: HALT (HR: 6.10; 95% CI: 2.59-14.29; P < 0.001), the mixed valve–type group (HR: 6.51; 95% CI: 2.38-17.81; P < 0.001), and prosthesis diameter (HR valve size per 3 mm [HR: 0.37; 95% CI: 0.17-0.79]; P = 0.011).ConclusionsDuring a median follow-up of more than 3 years, HALT was not associated with mortality or cerebrovascular events. However, we observed an association of HALT with symptomatic hemodynamic valve deterioration.  相似文献   

17.
Central Illustration. Main result of the study, including feasibility of mitral valve repair in 76% of cases, and better survival in the mitral valve replacement group.
  相似文献   

18.
Introduction and objectivesWe assessed the long-term hemodynamic performance of transcatheter heart valve (THV) by paired transthoracic echocardiography (TTE), and the incidence, characteristics and factors associated with THV structural valve degeneration (SVD).MethodsA total of 212 patients who underwent transcatheter aortic valve replacement and had a potential follow-up > 5 years with at least 1 TTE ≥ 1-year postprocedure were included. All patients had a TTE at 1 to 5 years and 36 had another one at 6 to 10 years. SVD was defined as subclinical (increase > 10 mmHg in mean transvalvular gradient +  decrease > 0.3 cm2 in valve area and/or new-onset mild or moderate aortic regurgitation) and clinically relevant (increase > 20 mmHg in mean transvalvular gradient + decrease > 0.6 cm2 in valve area and/or new-onset moderate-to-severe aortic regurgitation). Fifteen patients had a transesophageal echocardiography at the time of SVD diagnosis, and 85 an opportunistic computed tomography examination at 1 (0.5-2) years.ResultsTransvalvular mean gradient increased and valve area decreased over time (P < .01). At 8 years of follow-up, SVD occurred in 30.2% of patients (clinically relevant: 9.3%). Transesophageal echocardiography revealed thickened and reduced-mobility leaflets in 80% and 73% of SVD cases, respectively. No baseline or procedural factors were associated with SVD. THV underexpansion (3.5%) or eccentricity (8.2%) had no impact on valve hemodynamics/SVD at follow-up.ConclusionsA gradual THV hemodynamic deterioration occurred throughout a 10-year period, leading to SVD in ~30% of patients (clinically relevant in < 10%). Leaflet morphology/mobility were frequently impaired in SVD cases, but THV geometry did not influence valve hemodynamics or SVD.  相似文献   

19.
BackgroundAcute aortic syndrome is associated with aortic medial degeneration. 18F-sodium fluoride (18F-NaF) positron emission tomography (PET) detects microscopic tissue calcification as a marker of disease activity.ObjectivesIn a proof-of-concept study, this investigation aimed to establish whether 18F-NaF PET combined with computed tomography (CT) angiography could identify aortic medial disease activity in patients with acute aortic syndrome.MethodsPatients with aortic dissection or intramural hematomas and control subjects underwent 18F-NaF PET/CT angiography of the aorta. Aortic 18F-NaF uptake was measured at the most diseased segment, and the maximum value was corrected for background blood pool activity (maximum tissue-to-background ratio [TBRmax]). Radiotracer uptake was compared with change in aortic size and major adverse aortic events (aortic rupture, aorta-related death, or aortic repair) over 45 ± 13 months.ResultsAortic 18F-NaF uptake co-localized with histologically defined regions of microcalcification and elastin disruption. Compared with control subjects, patients with acute aortic syndrome had increased 18F-NaF uptake (TBRmax: 1.36 ± 0.39 [n = 20] vs 2.02 ± 0.42 [n = 47] respectively; P < 0.001) with enhanced uptake at the site of intimal disruption (+27.5%; P < 0.001). 18F-NaF uptake in the false lumen was associated with aortic growth (+7.1 mm/year; P = 0.011), and uptake in the outer aortic wall was associated with major adverse aortic events (HR: 8.5 [95% CI: 1.4-50.4]; P = 0.019).ConclusionsIn patients with acute aortic syndrome, 18F-NaF uptake was enhanced at sites of disease activity and was associated with aortic growth and clinical events. 18F-NaF PET/CT holds promise as a noninvasive marker of disease severity and future risk in patients with acute aortic syndrome. (18F Sodium Fluoride PET/CT in Acute Aortic Syndrome [FAASt]; NCT03647566)  相似文献   

20.
ObjectivesThe aim of this study was to evaluate and compare the outcomes of transcatheter self-expandable prostheses in patients with small annuli.BackgroundTranscatheter aortic heart valves appear to have better performance than surgical valves in terms of prosthesis-patient mismatch, especially in patients with aortic stenosis with small aortic annuli.MethodsTAVI-SMALL (International Multicenter Registry to Evaluate the Performance of Self-Expandable Valves in Small Aortic Annuli) is a retrospective registry of patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area <400 mm2 on computed tomography) treated with transcatheter self-expandable valves (n = 859; Evolut R, n = 397; Evolut PRO, n = 84; ACURATE, n = 201; Portico, n = 177). Primary endpoints were post-procedural mean aortic gradient, indexed effective orifice area, and rate of severe prosthesis-patient mismatch.ResultsPre-discharge gradients were consistently low in every group, with a slight benefit with the Evolut R (8.1 mm Hg; 95% confidence interval [CI]: 7.7 to 8.5 mm Hg) and Evolut PRO (6.9 mm Hg; 95% CI: 6.3 to 7.6 mm Hg) compared with the ACURATE (9.6 mm Hg; 95% CI: 8.9 to 10.2 mm Hg) and Portico (8.9 mm Hg; 95% CI: 8.2 to 9.6 mm Hg) groups (p < 0.001). Mean indexed effective orifice area was 1.04 cm2/m2 (95% CI: 1.01 to 1.08 cm2/m2) with a trend toward lower values with the Portico. No significant differences were reported in terms of severe prosthesis-patient mismatch (overall rate 9.4%; p = 0.134), permanent pacemaker implantation (15.6%), and periprocedural and 1-year adverse events. Pre-discharge more than mild paravalvular leaks were significantly more common with the Portico (19.2%) and less common with the Evolut PRO (3.6%) compared with the Evolut R (11.8%) and ACURATE (9%) groups.ConclusionsTranscatheter self-expandable valves showed optimal clinical and echocardiographic results in patients with small aortic annuli, although supra-annular functioning transcatheter heart valves seemed to slightly outperform intra-annular functioning ones. The role of transcatheter aortic valve replacement with self-expandable valves for the treatment of aortic stenosis in patients with small annuli needs to be confirmed in larger trials.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号