首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The macaque monkey is an important model for cognitive and sensory neuroscience that has been used extensively in behavioral, electrophysiological, molecular and, more recently, neuroimaging studies. However, macaque MRI has unique technical differences relative to human MRI, such as the geometry of highly parallel receive arrays, which must be addressed to optimize imaging performance. A 22‐channel receive coil array was constructed specifically for rapid high‐resolution anesthetized macaque monkey MRI at 3 T. A local Helmholtz transmit coil was used for excitation. Signal‐to‐noise ratios (SNRs) and noise amplification for parallel imaging were compared with those of single‐ and four‐channel receive coils routinely used for macaque MRI. The 22‐channel coil yielded significant improvements in SNR throughout the brain. Using this coil, the SNR in peripheral brain was 2.4 and 1.7 times greater than that obtained with single‐ or four‐channel coils, respectively. In the central brain, the SNR gain was 1.5 times that of both the single‐ and four‐channel coils. Finally, the performance of the array for functional, anatomical and diffusion‐weighted imaging was evaluated. For all three modalities, the use of the 22‐channel array allowed for high‐resolution and accelerated image acquisition. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

2.
For MRI at 16.4T, with a proton Larmor frequency of 698 MHz, one of the principal RF engineering challenges is to generate a spatially homogeneous transmit field over a larger volume of interest for spin excitation. Constructing volume coils large enough to house a receive array along with the subject and to maintain the quadrature symmetry for different loading conditions is difficult at this frequency. This calls for new approaches to RF coil design for ultra‐high field MR systems. A remotely placed capacitively tunable patch antenna, which can easily be adjusted to different loading conditions, was used to generate a relatively homogeneous excitation field covering a large imaging volume with a transversal profile similar to that of a birdcage coil. Since it was placed in front of the animal, this created valuable free space in the narrow magnet bore around the subject for additional hardware. To enhance the reception sensitivity, the patch antenna was combined with an actively detunable 3‐channel receive coil array. In addition to increased SNR compared to a quadrature transceive surface coil, we were able to get high quality gradient echo and spin‐echo images covering the whole rat brain. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

3.
Diffusion tensor imaging (DTI) of the brain provides essential information on the white matter integrity and structural connectivity. However, it suffers from a low signal‐to‐noise ratio (SNR) and requires a long scan time to achieve high spatial and/or diffusion resolution and wide brain coverage. With recent advances in parallel and simultaneous multislice (multiband) imaging, the SNR efficiency has been improved by reducing the repetition time (TR). However, due to the limited number of RF coil channels available on preclinical MRI scanners, simultaneous multislice acquisition has not been practical. In this study, we demonstrate the ability of multiband DTI to acquire high‐resolution data of the mouse brain with 84 slices covering the whole brain in 0.2 mm isotropic resolution without a coil array at 9.4 T. Hadamard‐encoding four‐band pulses were used to acquire four slices simultaneously, with the reduction in the TR maximizing the SNR efficiency. To overcome shot‐to‐shot phase variations, Hadamard decoding with a self‐calibrated phase was developed. Compared with single‐band DTI acquired with the same scan time, the multiband DTI leads to significantly increased SNR by 40% in the white matter. This SNR gain resulted in reduced variations in fractional anisotropy, mean diffusivity, and eigenvector orientation. Furthermore, the cerebrospinal fluid signal was attenuated, leading to reduced free‐water contamination. Without the need for a high‐density coil array or parallel imaging, this technique enables highly efficient preclinical DTI that will facilitate connectome studies.  相似文献   

4.
The design and construction of a dedicated RF coil setup for human brain imaging (1H) and spectroscopy (31P) at ultra‐high magnetic field strength (7 T) is presented. The setup is optimized for signal handling at the resonance frequencies for 1H (297.2 MHz) and 31P (120.3 MHz). It consists of an eight‐channel 1H transmit–receive head coil with multi‐transmit capabilities, and an insertable, actively detunable 31P birdcage (transmit–receive and transmit only), which can be combined with a seven‐channel receive‐only 31P array. The setup enables anatomical imaging and 31P studies without removal of the coil or the patient. By separating transmit and receive channels and by optimized addition of array signals with whitened singular value decomposition we can obtain a sevenfold increase in SNR of 31P signals in the occipital lobe of the human brain compared with the birdcage alone. These signals can be further enhanced by 30 ± 9% using the nuclear Overhauser effect by B1‐shimmed low‐power irradiation of water protons. Together, these features enable acquisition of 31P MRSI at high spatial resolutions (3.0 cm3 voxel) in the occipital lobe of the human brain in clinically acceptable scan times (~15 min). © 2015 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd.  相似文献   

5.
Sodium imaging is able to assess changes in ion content, linked to glycosaminoglycan content, which is important to guide orthopeadic procedures such as articular cartilage repair. Sodium imaging is ideally performed using double tuned RF coils, to combine high resolution morphological imaging with biochemical information from sodium imaging to assess ion content. The proton image quality of such coils is often harshly degraded, with up to 50% of SNR or severe acceleration loss as compared to single tuned coils. Reasons are that the number of proton receive channels often severely reduced and double tuning will degrade the intrinsic sensitivity of the RF coil on at least one of the nuclei. However, the aim of this work was to implement a double‐tuned sodium/proton knee coil setup without deterioration of the proton signal whilst being able to achieve acquisition of high SNR sodium images. A double‐tuned knee coil was constructed as a shielded birdcage optimized for sodium and compromised for proton. To exclude any compromise, the proton part of the birdcage is used for transmit only and interfaced to RF amplifiers that can fully mitigate the reduced efficiency. In addition, a 15 channel single tuned proton receiver coil was embedded within the double‐resonant birdcage to maintain optimal SNR and acceleration for proton imaging. To validate the efficiency of our coil, the designed coil was compared with the state‐of‐the‐art single‐tuned alternative at 7 T. B1+ corrected SNR maps were used to compare both coils on proton performance and g‐factor maps were used to compare both coils on acceleration possibilities. The newly constructed double‐tuned coil was shown to have comparable proton quality and acceleration possibilities to the single‐tuned alternative while also being able to acquire high SNR sodium images.  相似文献   

6.
In ultrahigh‐field MRI, such as 7 T, the signal‐to‐noise ratio (SNR) increases while transmit (Tx) field (B1+) can be degraded due to inhomogeneity and elevated specific absorption rate (SAR). By applying new array coil concepts to both Tx and receive (Rx) coils, the B1+ homogeneity and SNR can be improved. In this study, we developed and tested in vivo a new RF coil system for 7 T breast MRI. An RF coil system composed of an eight‐channel Tx‐only array based on a tic‐tac‐toe design (can be combined to operate in single‐Tx mode) in conjunction with an eight‐channel Rx‐only insert was developed. Characterizations of the B1+ field and associated SAR generated by the developed RF coil system were numerically calculated and empirically measured using an anatomically detailed breast model, phantom and human breasts. In vivo comparisons between 3 T (using standard commercial solutions) and 7 T (using the newly developed coil system) breast imaging were made. At 7 T, about 20% B1+ inhomogeneity (standard deviation over the mean) was measured within the breast tissue for both the RF simulations and 7 T experiments. The addition of the Rx‐only array enhances the SNR by a factor of about three. High‐quality MR images of human breast were acquired in vivo at 7 T. For the in vivo comparisons between 3 T and 7 T, an approximately fourfold increase of SNR was measured with 7 T imaging. The B1+ field distributions in the breast model, phantom and in vivo were in reasonable agreement. High‐quality 7 T in vivo breast MRI was successfully acquired at 0.6 mm isotropic resolution using the newly developed RF coil system.  相似文献   

7.
Composite MRI arrays consist of triplets where two orthogonal upright loops are placed over the same imaging area as a standard surface coil. The optimal height of the upright coils is approximately half the width for the 7 cm coils used in this work. Resistive and magnetic coupling is shown to be negligible within each coil triplet. Experimental evaluation of imaging performance was carried out on a Philips 3 T Achieva scanner using an eight‐coil composite array consisting of three surface coils and five upright loops, as well as an array of eight surface coils for comparison. The composite array offers lower overall coupling than the traditional array. The sensitivities of upright coils are complementary to those of the surface coils and therefore provide SNR gains in regions where surface coil sensitivity is low, and additional spatial information for improved parallel imaging performance. Near the surface of the phantom the eight‐channel surface coil array provides higher overall SNR than the composite array, but this advantage disappears beyond a depth of approximately one coil diameter, where it is typically more challenging to improve SNR. Furthermore, parallel imaging performance is better with the composite array compared with the surface coil array, especially at high accelerations and in locations deep in the phantom. Composite arrays offer an attractive means of improving imaging performance and channel density without reducing the size, and therefore the loading regime, of surface coil elements. Additional advantages of composite arrays include minimal SNR loss using root‐sum‐of‐squares combination compared with optimal, and the ability to switch from high to low channel density by merely selecting only the surface elements, unlike surface coil arrays, which require additional hardware. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

8.
The quality of an RF detector coil design is commonly judged on how it compares with other coil configurations. The aim of this article is to develop a tool for evaluating the absolute performance of RF coil arrays. An algorithm to calculate the ultimate intrinsic signal‐to‐noise ratio (SNR) was implemented for a spherical geometry. The same imaging tasks modeled in the calculations were reproduced experimentally using a 32‐element head array. Coil performance maps were then generated based on the ratio of experimentally measured SNR to the ultimate intrinsic SNR, for different acceleration factors associated with different degrees of parallel imaging. The relative performance in all cases was highest near the center of the samples (where the absolute SNR was lowest). The highest performance was found in the unaccelerated case and a maximum of 85% was observed with a phantom whose electrical properties are consistent with values in the human brain. The performance remained almost constant for 2‐fold acceleration, but deteriorated at higher acceleration factors, suggesting that larger arrays are needed for effective highly‐accelerated parallel imaging. The method proposed here can serve as a tool for the evaluation of coil designs, as well as a tool to guide the development of original designs which may begin to approach the optimal performance. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
The purpose of this work is to illustrate a new coil decoupling strategy and its application to a transmit/receive sodium/proton phased array for magnetic resonance imaging (MRI) of the human brain. We implemented an array of eight triangular coils that encircled the head. The ensemble of coils was arranged to form a modified degenerate mode birdcage whose eight shared rungs were offset from the z‐axis at interleaved angles of ±30°. This key geometric modification resulted in triangular elements whose vertices were shared between next‐nearest neighbors, which provided a convenient location for counter‐wound decoupling inductors, whilst nearest‐neighbor decoupling was addressed with shared capacitors along the rungs. This decoupling strategy alleviated the strong interaction that is characteristic of array coils at low frequency (32.6 MHz in this case) and allowed the coil to operate efficiently in transceive mode. The sodium array provided a 1.6‐fold signal‐to‐noise ratio advantage over a dual‐nuclei birdcage coil in the center of the head and up to 2.3‐fold gain in the periphery. The array enabled sodium MRI of the brain with 5‐mm isotropic resolution in approximately 13 min, thus helping to overcome low sodium MR sensitivity and improving quantification in neurological studies. An eight‐channel proton array was integrated into the sodium array to enable anatomical imaging.  相似文献   

10.
A 15‐channel transmit–receive (transceive) radiofrequency (RF) coil was developed to image the human brain at 7 T. A hybrid decoupling scheme was implemented that used both capacitive decoupling and the partial geometric overlapping of adjacent coil elements. The decoupling scheme allowed coil elements to be arrayed along all three Cartesian axes; this facilitated shimming of the transmit field, B, and parallel imaging acceleration along the longitudinal direction in addition to the standard transverse directions. Each channel was independently controlled during imaging using a 16‐channel console and a 16 × 1‐kW RF amplifier–matrix. The mean isolation between all combinations of coil elements was 18 ± 7 dB. After B shimming, the standard deviation of the transmit field uniformity was 11% in an axial plane and 32% over the entire brain superior to the mid‐cerebellum. Transmit uniformity was sufficient to acquire fast spin echo images of this region of the brain with a single B shim solution. Signal‐to‐noise ratio (SNR) maps showed higher SNR in the periphery vs center of the brain, and higher SNR in the occipital and temporal lobes vs the frontal lobe. Parallel imaging acceleration in a rostral–caudal oblique plane was demonstrated. The implication of the number of channels in a transmit–receive coil was discussed: it was determined that improvements in SNR and B shimming can be expected when using more than 15 independently controlled transmit–receive channels. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

11.
There is a need to obtain higher specificity in the detection of breast lesions using MRI. To address this need, Dynamic Contrast‐Enhanced (DCE) MRI has been combined with other structural and functional MRI techniques. Unfortunately, owing to time constraints structural images at ultra‐high spatial resolution can generally not be obtained during contrast uptake, whereas the relatively low spatial resolution of functional imaging (e.g. diffusion and perfusion) limits the detection of small lesions. To be able to increase spatial as well as temporal resolution simultaneously, the sensitivity of MR detection needs to increase as well as the ability to effectively accelerate the acquisition. The required gain in signal‐to‐noise ratio (SNR) can be obtained at 7T, whereas acceleration can be obtained with high‐density receiver coil arrays. In this case, morphological imaging can be merged with DCE‐MRI, and other functional techniques can be obtained at higher spatial resolution, and with less distortion [e.g. Diffusion Weighted Imaging (DWI)]. To test the feasibility of this concept, we developed a unilateral breast coil for 7T. It comprises a volume optimized dual‐channel transmit coil combined with a 30‐channel receive array coil. The high density of small coil elements enabled efficient acceleration in any direction to acquire ultra high spatial resolution MRI of close to 0.6 mm isotropic detail within a temporal resolution of 69 s, high spatial resolution MRI of 1.5 mm isotropic within an ultra high temporal resolution of 6.7 s and low distortion DWI at 7T, all validated in phantoms, healthy volunteers and a patient with a lesion in the right breast classified as Breast Imaging Reporting and Data System (BI‐RADS) IV. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

12.
Earlier work on RF metasurfaces for preclinical MRI has targeted applications such as whole‐body imaging and dual‐frequency coils. In these studies, a nonresonant loop was used to induce currents into a metasurface that was operated as a passive inductively powered resonator. However, as we show in this study, the strategy of using a resonant metasurface reduces the impact of the loop on the global performance of the assembled coil. To mitigate this deficiency, we developed a new approach that relies on the combination of a commercial surface coil and a coupled‐wire structure operated away from its resonance. This strategy enables the extension of the sensitive volume of the surface coil while maintaining its local high sensitivity without any hardware modification. A wireless coil based on a two parallel coupled‐wire structure was designed and electromagnetic field simulations were carried out with different levels of matching and coupling between both components of the coil. For experimental characterization, a prototype was built and tested at two frequencies, 300 MHz for 1H and 282.6 MHz for 19F at 7 T. Phantom and in vivo MRI experiments were conducted in different configurations to study signal and noise figures of the structure. The results showed that the proposed strategy improves the overall sensitive volume while simultaneously maintaining a high signal‐to‐noise ratio (SNR). Metasurfaces based on coupled wires are therefore shown here as promising and versatile elements in the MRI RF chain, as they allow customized adjustment of the sensitive volume as a function of SNR yield. In addition, they can be easily adapted to different Larmor frequencies without loss of performance.  相似文献   

13.
The performance of multichannel transmit coil layouts and parallel transmission (pTx) RF pulse design was evaluated with respect to transmit B1 (B1 +) homogeneity and specific absorption rate (SAR) at 3 T for a whole body coil. Five specific coils were modeled and compared: a 32‐rung birdcage body coil (driven either in a fixed quadrature mode or a two‐channel transmit mode), two single‐ring stripline arrays (with either 8 or 16 elements), and two multi‐ring stripline arrays (with two or three identical rings, stacked in the z axis and each comprising eight azimuthally distributed elements). Three anatomical targets were considered, each defined by a 3D volume representative of a meaningful region of interest (ROI) in routine clinical applications. For a given anatomical target, global or local SAR controlled pTx pulses were designed to homogenize RF excitation within the ROI. At the B1 + homogeneity achieved by the quadrature driven birdcage design, pTx pulses with multichannel transmit coils achieved up to about eightfold reduction in local and global SAR. When used for imaging head and cervical spine or imaging thoracic spine, the double‐ring array outperformed all coils, including the single‐ring arrays. While the advantage of the double‐ring array became much less pronounced for pelvic imaging, with a substantially larger ROI, the pTx approach still provided significant gains over the quadrature birdcage coil. For all design scenarios, using the three‐ring array did not necessarily improve the RF performance. Our results suggest that pTx pulses with multichannel transmit coils can reduce local and global SAR substantially for body coils while attaining improved B1 + homogeneity, particularly for a “z‐stacked” double‐ring design with coil elements arranged on two transaxial rings. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

14.
A new 2 T 3‐element orthogonal knee coil array based on the three‐dimensional orthogonality principle was designed, constructed and used in a series of pilot magnetic resonance imaging (MRI) studies on a standardized phantom, and human and pig knees. The coil elements within this new coil array are positioned orthogonal to one another allowing problematic mutual coupling effects to be minimized without the use of any passive mutual decoupling schemes. The proposed method is appropriate for the design of transmit, receive and/or transceive radiofrequency (RF) coil arrays for applications in animal/human MRI and spectroscopic studies. Experimental results demonstrated that the 3‐element orthogonal knee coil array could be angled arbitrarily, including at 90°, relative to the main static magnetic field (B0) whilst maintaining normal operation with minimal loss of efficiency and functionality. Initial trials with a pig knee specimen further showed that the greatest signal intensity in the patellar ligament (parallel collagen fibres) was observed when the orthogonal knee coil array and the pig knee specimen were angled at ~55° to B0, which may have potential uses in magic angle MR applications. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

15.
Although the quality and speed of MR images have vastly improved with the development of novel RF coil technologies, the engineering expertise required to implement them is often not available in many animal in vivo MR laboratories. We present here an open birdcage coil design which is easily constructed with basic RF coil expertise and produces high quality images. The quality and advantages of mouse cardiac MR images acquired with open birdcage coils were evaluated and compared to images acquired with a bent single loop surface, and standard birdcage coils acquired at 4.7 Tesla. Two low pass open birdcage coils, two single loop surface coils, and a low pass volume birdcage coil were constructed and their B(1) distributions were evaluated and compared. The calculated average signal-to-noise ratio for the left ventricular wall was 10, 23 and 32 for the volume birdcage coil, single loop surface coil and open birdcage coil, respectively. The results demonstrate that the open birdcage coil provides greater sensitivity than the volume coil and a higher signal/contrast-to-noise ratio and B(1) homogeneity than the single loop surface coil. The open birdcage coil offers easy access and better quality mouse cardiac imaging than both the single loop surface coil and volume birdcage coil and does not require extensive RF engineering expertise to construct.  相似文献   

16.
Parallel imaging is essential for the acceleration of abdominal and pelvic 2D multi‐slice imaging, in order to reduce scan time and mitigate motion artifacts. Controlled Aliasing In Parallel Imaging Results IN Higher Acceleration (CAIPIRINHA) accelerated imaging has been shown to increase the signal‐to‐noise ratio (SNR) significantly compared with in‐plane parallel imaging with similar acceleration. We hypothesize that for CAIPIRINHA‐accelerated abdominal imaging the consistency of image quality and SNR is more difficult to achieve due to the subject‐specific coil sensitivity profiles, caused by (1) flexible coil placement; (2) variations in anatomy; and (3) variations in scan coverage along the superior–inferior direction. To test this, a mathematical framework is introduced that calculates the (retained) SNR for in‐plane and simultaneous multi‐slice (SMS)‐accelerated acquisitions. Moreover, this framework was used to optimize the sampling pattern by maximizing the local SNR within a region of interest (ROI) through non‐linear, RF‐induced CAIPIRINHA slice shifts. The framework was evaluated on 14 healthy subjects and the optimized sampling pattern was compared with in‐plane acceleration and CAIPIRINHA acceleration with linear slice shifts, which are primarily used in brain imaging. We demonstrate that the field of view (FOV) in the superior–inferior direction, the coil positioning and the individual anatomy have a large impact on the image SNR (changes up to 50% for varying coil positions and 40% differences between subjects) and image artifacts for simultaneous multi‐slice acceleration. Consequently, sampling patterns have to be optimized for acquisitions employing different FOVs and ideally on an individual basis. Optimization of the sampling pattern, which exploits non‐linear shifts between slices, showed a considerable SNR increase (10–30%) for higher acceleration factors. The framework outlined in this article can be used to optimize sampling patterns for a broad range of accelerated body acquisitions on an individual basis. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

17.
The goal of this study was to evaluate a new method of combining multi‐channel 1H MRSI data by direct use of a matching imaging scan as a reference, rather than computing sensitivity maps. Seven healthy volunteers were measured on a 7‐T MR scanner using a head coil with a 32‐channel array coil for receive‐only and a volume coil for receive/transmit. The accuracy of prediction of the phase of the 1H MRSI data with a fast imaging pre‐scan was investigated with the volume coil. The array coil 1H MRSI data were combined using matching imaging data as coil combination weights. The signal‐to‐noise ratio (SNR), spectral quality, metabolic map quality and Cramér–Rao lower bounds were then compared with the data obtained by two standard methods, i.e. using sensitivity maps and the first free induction decay (FID) data point. Additional noise decorrelation was performed to further optimize the SNR gain. The new combination method improved significantly the SNR (+29%), overall spectral quality and visual appearance of metabolic maps, and lowered the Cramér–Rao lower bounds (?34%), compared with the combination method based on the first FID data point. The results were similar to those obtained by the combination method using sensitivity maps, but the new method increased the SNR slightly (+1.7%), decreased the algorithm complexity, required no reference coil and pre‐phased all spectra correctly prior to spectral processing. Noise decorrelation further increased the SNR by 13%. The proposed method is a fast, robust and simple way to improve the coil combination in 1H MRSI of the human brain at 7 T, and could be extended to other 1H MRSI techniques. © 2013 The Authors. NMR in Biomedicine published by John Wiley & Sons, Ltd.  相似文献   

18.
fMRI has established itself as the main research tool in neuroscience and brain cognitive research. The common marmoset (Callithrix jacchus) is a non‐human primate model of increasing interest in biomedical research. However, commercial MRI coils for marmosets are not generally available. The present work describes the design and construction of a four‐channel receive‐only surface RF coil array with excellent signal‐to‐noise ratio (SNR) specifically optimized for fMRI experiments in awake marmosets in response to somatosensory stimulation. The array was designed as part of a helmet‐based head restraint system used to prevent motion during the scans. High SNR was obtained by building the coil array using a thin and flexible substrate glued to the inner surface of the restraint helmet, so as to minimize the distance between the array elements and the somatosensory cortex. Decoupling between coil elements was achieved by partial geometrical overlapping and by connecting them to home‐built low‐input‐impedance preamplifiers. In vivo images show excellent coverage of the brain cortical surface with high sensitivity near the somatosensory cortex. Embedding the coil elements within the restraint helmet allowed fMRI data in response to somatosensory stimulation to be collected with high sensitivity and reproducibility in conscious, awake marmosets. Published 2013. This article is a U.S. Government work and is in the public domain in the USA.  相似文献   

19.
目的 比较小孔径正交相控阵小动物实验线圈与C3表面线圈在大鼠头部磁共振成像(MRI)检查的成像质量.方法 将10只雄性SD大鼠分别应用2种线圈进行头部MRI检查.测量大脑皮层、小脑、脑干、肌肉及眼球内的房水等部位的信号强度及背景噪声值,计算信噪比(SNR);由2位放射科医生对图像质量进行评分,将测量数据进行统计分析.结果 所有图像均得到了大脑皮层、小脑、脑干、肌肉及眼球内的房水等部位的SNR值.两种线罔成像质量比较,大脑皮层T1WI横断位(SNRsense-body=41.3±23.5;SNR C3=10.3±0.5;t=-3.21)、T2WI矢状位(SNR sense-body=63.8±16.6;SNR C3=37.9±4.4:t=-4.00)以及T2WI冠状位(SNR sense.body=91.6±23.8;SNR C3=38.5±11.8;t=-5.69)图像SNR差异均有统计学意义(P<0.01);且在小脑、脑干以及眼球房水测量的结果亦相仿;肌肉组织仅在T1WI横断位(SNR sense-body=39.9±21.1;SNR C3=8.3±1.7;t=-3.64)和T2WI冠状位(SNR sense-body=23.5±9.8:SNR C3=11.9±4.1;t=-3.10)的SNR差异有统计学意义(P<0.01).采用小孔径正交相控阵线圈检查获得的图像中T2WI冠状面得分最高,而2种线圈检查获得的弥散加权成像(DWI)图像质量评分均最低.结论 在大鼠头部成像MRI检查中,小孔径正交相控阵小动物实验线圈的信噪比和图像质量优于现在经常应用的C3表面线圈.  相似文献   

20.
In this study, the performance of an integrated body-imaging array for 7 T with 32 radiofrequency (RF) channels under consideration of local specific absorption rate (SAR), tissue temperature, and thermal dose limits was evaluated and the imaging performance was compared with a clinical 3 T body coil. Thirty-two transmit elements were placed in three rings between the bore liner and RF shield of the gradient coil. Slice-selective RF pulse optimizations for B1 shimming and spokes were performed for differently oriented slices in the body under consideration of realistic constraints for power and local SAR. To improve the B1+ homogeneity, safety assessments based on temperature and thermal dose were performed to possibly allow for higher input power for the pulse optimization than permissible with SAR limits. The results showed that using two spokes, the 7 T array outperformed the 3 T birdcage in all the considered regions of interest. However, a significantly higher SAR or lower duty cycle at 7 T is necessary in some cases to achieve similar B1+ homogeneity as at 3 T. The homogeneity in up to 50 cm-long coronal slices can particularly benefit from the high RF shim performance provided by the 32 RF channels. The thermal dose approach increases the allowable input power and the corresponding local SAR, in one example up to 100 W/kg, without limiting the exposure time necessary for an MR examination. In conclusion, the integrated antenna array at 7 T enables a clinical workflow for body imaging and comparable imaging performance to a conventional 3 T clinical body coil.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号